1 DRY TYPE TRANSFORMERS Single-phase, Three-phase/Single-phase, Three-phase/Two-phase,Three-phase 1.1 kv to 7.2kV Class
2 Dry Type Transformers Transformers meant to be installed in a dry and air conditioned room or in a PTI AUGIER type substation. ELECTRICAL CHARACTERISTICS : Power rating and type : Single-phase : TMAI : kva Three-single : TTMAI : kva Three-two : TTBAI : kva Three-phase : TTAI : kva Insulation voltage : 1.1 kv kv kv Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V V V V V and 6600 V. Secondary load voltage : 230 V V V V V and 6600 V. Couplings : Standard : Three-phase transformer : Step-down Dyn11 - Step-up YNd1 single-phase transformer :Ii0 Specific : Three-single transformer, Leblanc three-two transformer, other couplings on request. Manufacturing specifications on request : Inrush current transformer reduced or very reduced. CONNEXION: Primary and secondary connesion on copper slots, by the upper side of the transformer. STANDARD ACCESSORIES : Empty setting plugs : Three outputs on slots. Two earthing switches. Lifting lugs. Four rollers for 10 kva and higher power rating transformers. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. Single-phase transformer, TMAI type, with IP21 encolsure, fuse terminal 3200 V and locking. 2
3 CONSTRUCTION : Magnetical circuits with crystal made sheet metal, oriented, with low losses. Copper windings, vacuum impregnated of H class and applying of a fungicide varnish. Metallic flanges. Ironed chassis with rollers. Wooden terminals plate bakelised. Cooling Use Color : in natural air : NA. : use in dry, air conditioned rooms, at a room temperature of -15 C ; + 40 C. : RAL 7035 gray. STANDARDS AND TESTS : Conforms to NF C NF C IEC standards. Other specifications on request. Routine tests U.T.E made on each transformer, specific tests on request.. Dry type transformer, naked presentation on frame Connexion plates Tap changer MV side view LV side dismantle panel Fixation by screw Lifting lugs Connexion plates Dry type transformer With IP21 enclosure Side panel dismantling (cables passage) Fixation by screw Bakélite matter To be screwed on request rollers Signaletic plate Firm plate LV side dismantling panel 3
4 Three-phase dry Type Transformers TTAI ELECTRICAL CHARACTERISTICS : Power rating: kva Insulation voltage : 1.1 kv kv kv Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V V V V V and 6600 V. Secondary load voltage : 400 V V V V and 6600 V. Couplings : Step-down Dyn11 - Step-up YNd1, other couplings on request. CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % or +- 5% output on slots. Two earthing terminals. Lifting lugs. Four rollers for 10 kva and higher power rating transformers. Naked presentation on frame : IP00. OPTIONAL ACCESSORIES Painted sheet metal enclosure with natural airing upwards, IP21. Connexion on pluggable terminals 3200 V or 5500 V. HRC fuses protection integrated above the protection envelop. Thermal protection by thermal probe integrated to windings, one or two thresholds protection. Tap changers +/- 2,5 % +/- 5%. Keyhole locking of the protection envelop and or pluggable terminals. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. ELECTRICAL CHARACTERISTICS Power rating (kva) Copper losses at 75 C (W) Iron losses (W) Voltage drop (% ) at Cos = 0.83 CC tension (%) at 75 C Empty current (%)
5 TTAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME - STEP DOWN TRANSFORMER Power rating (kva) A B C D E Weight (kg) Protection degree IP00 SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE - STEP DOWN TRANSFORMER Power rating (kva) A B C D E Weight (kg) Protection degree IP21 5
6 Single-phase Dry Type Transformers TMAI ELECTRICAL CHARACTERISTICS : Power rating: 5-7, kva Insulation voltage : 1.1 kv kv kv Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V V V V. Secondary load voltage : 230 V V V. Couplings : Standard : single-phase transformer : Ii0 CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % ou +- 5% sorties sur plages. Two earthing terminals. Lifting lugs. Four rollers for 10 kva and higher power rating transformers. Naked presentation on IP00 frame. OPTIONAL ACCESSORIES Painted sheet metal enclosure with natural airing upwards, IP21. Connexion on pluggable terminals. HRC fuses protection integrated above the protection envelop. Thermal protection by thermal probe integrated to windings, one or two thresholds protection. Tap changers +/- 2,5 % +/- 5%. Keyhole locking of the protection envelop and or pluggable terminals. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. ELECTRICAL CHARACTERISTICS Power rating (kva) 5 7, Copper losses at 75 C (W) Iron losses (W) Voltage drop (% ) at Cos = 0.83 Cc tension (%) at 75 C Empty current (%)
7 TMAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME Power rating (kva) 5 7, A B C D E Weight (kg) Protection degree IP00 SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE Power rating(kva) 5 7, A B C D E Weight (kg) Protection degree IP121 7
8 With constant improvements, the manufacturer may alter information without prior warning AUGIER IS CERTIFIED ISO 9001 SINCE
The construction features of EdM transformers
S GENERAL Thanks to the long experience of EdM and to the sophisticated calculation and design techniques, our transformers for distribution, rectifiers and distribution can be realised in a very large
More informationDRY TYPE TRANSFORMERS
DRY TYPE Trafotek transformers are made to meet customer requirements in demanding applications. We are specially focused on manufacturing transformers for different types of frequency converters and special
More informationUniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions
UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions ABB a global leader ABB is a global leader in power and automation technologies that
More informationCast resin transformers
Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00
More informationKey features. DESIGNS: - Conservator type - Hermetically sealed
Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the
More information*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56
T *(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56 TUNISIE TRANSFORMATEUR S.A :ULWWHQE\ M. BOUMALLA Adel Checked by : Mll. LAOUINI Radhia Approved by : M.LARIBI Mohamed Kamel %XVLQHVV'HSDUWPHQW,PP(O+DELE%XUHDX1ƒ%ORF%/HV%HUJHVGXODF$RXLQD
More informationOLIVER ONLINE VOLTAGE REGULATION
CAST-RESIN TRANSFORMERS ACCORDING TO IEC/EN 60076, VDE 0532, DIN 42523, DIN EN 50541-1, EU NR. 548/2014 OLIVER ONLINE VOLTAGE REGULATION With Ruhstrat transformers you provide the right voltage for the
More informationTGK Prefabricated Substation Technical Data
TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary
More informationMinera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards
Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral
More informationYOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS
YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS 1 TABLE OF CONTENTS ABOUT SVEL GROUP CAST-RESIN TRANSFORMERS ACCESSORIES AND OPTIONAL EQUIPMENT ENCLOSURE AND HOUSING TESTS AND QUALITY
More informationDistribution transformers Efficiency over life-cycle
Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationCAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00
CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00 1 HISTORY INESING SRL is a dynamic and modern company, very well known in the design and production of dry type (cast resin ) transformer up to 36kV -10MVA,
More informationP2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets
P2 : About Us P3 : Elsewedy Transformers P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers P7 : Technical Data Sheets P8 : Transformer s Outline Drawing P9 : Accessories About Us
More information56-SDMS-07 REV. 01 SPECIFICATIONS FOR
56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice
More informationCOMPACT SUBSTATION GUIDE
COMPACT SUBSTATION GUIDE Certificate Number FM35831 1 The substation is a compact enclosure consisting of MV switchgear, a transformer and an LV switchboard located in three separate compartments which
More informationBC IMPREGO Impregnated dry type transformers and autotransformers
atalogue B IMPREGO Impregnated dry type transformers and autotransformers Low Voltage Distribution schneider-electric.com LV transformers and autotransformers Tailored to your needs ontents Your requirements
More informationLV Capacitor CLMD Reliability for Power Factor Correction
LV Capacitor CLMD Reliability for Power Factor Correction Reliability for power factor correction CLMD construction The CLMD capacitor consists of a number of wound elements made with a dielectric of metallized
More informationABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers
ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type
More informationProduct presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does
More informationVariable speed asynchronous motors with FCR brake LSMV FCR. General information
General information GENERAL USE : U.G. Closed three-phase asynchronous brake motors, LSMV series with failsafe continuous (dc) brake, according to IEC 3, 72, EN 50281. Single speed : 0.25 to 11, frame
More informationThree-phase isolating transformers for photovoltaic and wind-power systems
BTTTFV SERIES VERY LOW LOSSES THREE PHASE "GREEN ENERGY" TRANSFORMERS DRY TYPE THREE PHASES TRANSFORMERS Rated frequency: 50/60Hz Rated primary voltage: 400V Rated secondary voltage: 400V Group: YNyn0
More informationCertified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers
Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind
More informationCAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION
CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA
More information34-SDMS-02 SPECIFICATIONS FOR
SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE
More informationIsolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations
Three-phase isolating transformers for the supply of three-phase loads in medical locations DS0107_D00105_00_D_XXEN/05.2015 Three-phase isolating transformers for the supply of three-phase loads in medical
More informationFLSD (E) Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information
(E) Atmospheres containing explosive GAS General information Flameproof totally enclosed three-phase asynchronous motors, FLSD (E) series, according to IEC 60034, 60038, 60072, 60079-0 and 60079-1, EN
More informationMax. Input Power (W) Inrush Current (A pk /µs)
Output Power (W) Output Voltage (V) Output Current (A) Tcase Max 150 60~210 0.70 80 C Wiring Diagram Input Current 1.4A@120VAC 0.6A@277VAC 0.67A@250VDC Max. Input Power (W) Inrush Current (A pk /µs) Max.
More informationCompact Integrated Distribution Substation (CIDS)
Compact Integrated Distribution Substation (CIDS) 1- INTRODUCTION SAVE SPACE 2.5m 2 footprint for CIDS up to 630kVA. SAVE THE ENVIRONMENT No SF6, No PCB. SAVE MONEY Save up to 50% from conventional package
More informationABB Ltd. FACTORY IN HANOI
ABB LTD. ABB Ltd. was originally a JVC between the Vietnamese Transformers Manufacture CTBT and the International Electromechanical group ABB Company was established 1st Sep. 1994 Distribution Transformers
More information1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled
1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R
More informationCAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION
CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA CENTRAL & SOUTH AMERICA MIDDLE EAST &
More informationThree-Phase Ventilated
Three-Phase Ventilated 2 15 to 2,500 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationLSPXMV FCR Atmospheres containing explosive dust FCR asynchronous brake motors. General information
General information GENERAL USE : U.G. Enclosed three-phase brake asynchronous motors, LSPXMV series with failsafe brake, according to IEC 6003, 60072, EN 50281. Single speed : 0.25 to 11, frame size from
More informationDISTRIBUTION TRANSFORMERS CATALOGUE
DISTRIBUTION TRANSFORMERS CATALOGUE COMPANY INFORMATION ARTRANS S.A. started off as a small factory in April 2, 1982 located in Mendoza, Argentina. Now, three decades later it is a globally recognized
More informationIndustrial Control Transformers
Industrial Control Transformers 5 The SBE - Encapsulated Series The SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationGeneral Purpose Buck - Boost Wiring Diagrams... 86
SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8 LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for
More informationLV Capacitor CLMD03 Power Module Instruction manual
LV Capacitor CLMD03 Power Module Instruction manual Table of Contents 1 Safety... 3 2 Upon reception... 3 2.1 Inspection on reception... 3 2.2 Storage- transportation handling... 3 3 Hardware Description...
More informationContact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series
Contact us Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series We provide motors and generators, services and expertise to save energy and
More informationLIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016
No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979
More informationIsolating transformer ES710
Single-phase isolating transformers for the design of medical IT systems Also available as energy-efficient Green Line (GL) edition ES710_D00109_03_D_XXEN/10.2016 Single-phase isolating transformers for
More information500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled
500 kva Pad Mount Transformer - 12470V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Page: 1 The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU
More informationCAST RESIN TRANSFORMERS
CAST RESIN TRANSFORMERS 2 CAST RESIN TRANSFORMERS GRAVITY LINE WHO WE ARE SGB-SMIT AT A GLANCE 415 YEARS OF EXPERIENCE Combined, more than Basis for know-how and for know-why More than 2,000 EMPLOYEES
More information2013 JEAN MÜLLER Products
2013 JEAN MÜLLER Products Company JEAN MÜLLER JEAN MÜLLER was founded in 1897 in Germany, when the applications of electricity were still in their very early days. The company chose as its basic activity
More informationCPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards
Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1
More informationSingle-phase step voltage regulators
Voltage Regulators Catalog Data CA225001EN Supersedes 225-10 February 2014 COOPER POWER SERIES General Eaton's Cooper Power series VR-32 singlephase step voltage regulators are tap-changing autotransformers.
More informationCAST RESIN TRANSFORMERS
MODEL TAM CAST RESIN - TAM TYPE Epoxy cast resin dry-type transformers are recommended to operate in places that require security, the materials used in its construction are hard to combust and are self-extinguishable
More informationABB Transformers Egypt
Kamel Elhamy, 2013 ABB Transformers Egypt Our transformers support the systems that keep our world running ABB January 31, 2012 Slide 1 Factory Information Key data 2012 Annual volume 40 MUSD Employees
More informationTechnical Specifications
LT Distribution Box Technical Specifications 1. SCOPE 1.1 This specification covers design, manufacture, testing at manufacturer works before dispatch and supply of L.T. Distribution Cabinet suitable for
More informationINESING GROUP. Power System Solution
INESING GROUP INESING GROUP Power System Solution Power System Solution INESING Group Via Dell'Industria 18B 24040 Casirate D'Adda Italy t: +39 3388263363 f: +39 04381890521 e: info@inesing.com introduction
More informationProduct Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A
Proficient. Innovative. Customer-orientated Transformers up to 8MVA AC/DC Reactors up to 3000A Power Transformers Cast Resin Transformers High-Current Transformers AC/DC Reactors Variable Transformers
More informationINESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation
MOBILE SUBSTATIONS Energy Solution INTERNATIONAL FAIR MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution Mobile Substations Applications of Inesing
More informationTransformer Stations
ISO 9001 99-320 Żychlin, ul. Narutowicza 70 www.ftz.com.pl Secretary s Office Tel.: +48 24 285 46 05, Fax: +48 24 285 46 31, zarzad@ftz.com.pl Marketing and Sales Department Tel.: +48 24 285 18 53, Fax:
More informationDistribution Transformers. The most comprehensive range of solutions for distribution transformer applications
Distribution The most comprehensive range of solutions for distribution transformer applications Oil Type Single-phase and three-phase transformers for the range above 16 kva and up to 72.5 kv. These units
More informationFuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A
DISTRIBUTION SOLUTIONS Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A Superior performance versus standard fuses ensuring up to 40% faster protection in case of low
More informationSingle-Phase Step Voltage Regulators
Voltage Regulators Catalog Data CA225001EN Supersedes March 2017 COOPER POWER SERIES Single-Phase Step Voltage Regulators Contents GENERAL....2 STANDARD FEATURES....4 OPTIONAL ACCESSORIES...4 ARRESTERS....4
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a
ÒÌÃ TRNSFORMERS ÒÌÃ three-phase oil transformers are intended for transforming of electric energy in networks of power systems and in energy consumer networks. Transformers are designed for indoor or outdoor
More informationEcodesign Transformers Energizing the World since a company of Rauscher & Stoecklin SERW ZREW Tesar
Ecodesign Transformers Energizing the World since 1979 a company of Rauscher & Stoecklin SERW ZREW Tesar Sustainability 2 Table of content Energy 20 20 20 4 The standards 6 Our proposal 7 Technical Details
More informationDYNACOMP. The top-class reactive power compensator
DYNACOMP The top-class reactive power compensator Dynacomp vs Electromechanical switching of capacitors Electromechanical switching of capacitors The Dynacomp : the top-class dynamic compensator Transients
More informationGAS INSULATED VOLTAGE TRANSFORMERS.
GAS INSULATED VOLTAGE TRANSFORMERS. This document may be subject to changes. Contact ARTECHE NISSIN to confirm the characteristics and availability of the products described here. CONTENTS 1. Presentation
More informationCGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.
MV Switchgear for CGMCOSMOS Fully gas insulated modular and compact (RMU)system Up to 24 kv Up to 27 kv mediumvoltage mediumvoltageag AG Langackerstrasse Langackerstrasse 25 25 CH CH 6330 6330 Cham Cham
More informationSingle-Phase Ventilated
Single-Phase Ventilated 1 15 to 1,650 kva Applications n For general loads, including lighting, industrial and commercial applications Specifications n Meets DOE-2016 and C802 standards for energy efficiency
More informationSBOX1250kVA Technical Data Sheet
SBOX1250kVA Technical Data Sheet Key words: Montage on a concrete shape foreseen with cables trench; Montage and replacement of the GFCs and Power Transformer through side doors; Lifting from the top,
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationLV Capacitor Bank APC
LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks The ABB comprehensive solution for automatic
More informationormaset-m PREFABRICATED METALLIC TRANSFORMER SUBSTATION
IG-199-GB GENERAL INSTRUCTIONS FOR IG-199-GB General Instructions ormaset-m Transformer Substations Primary Distribution Switchgear Secondary Distribution Switchgear Protection and Automation Low Voltage
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationInnovac SVS/08 - SVS/ kv modular switchgear
Innovac SVS/08 - SVS/ 3.6-4 kv modular switchgear Product Focus Epoxy resin insulated switchgear in sheet steel enclosure with vacuum interrupters Total reliability in switching, metering and distributing
More informationtests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.
tests ( Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed. electrical tests These tests verify contractual
More informationCompany Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances
COMPANY PROFILE Company Overview Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances GEOGRAPHIC SCOPE QUALITY GUARANTEED Trasfeco produces
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25
More informationExcitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.
Turbo - Generator Type: QF Series 1. General The generator is a two pole, cylindrical rotor type synchronous machine, directly coupled with steam turbine. It has a closed-circuit cooling system to cool
More informationApplications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders
Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000
More informationTransformers Global product offering
Distributor Line Card Transformers Global product offering ABB is a major transformer manufacturer throughout the world and offers both liquid-filled and dry-type transformers as well as services for complete
More informationCONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances
CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding and Insulation
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationFCR asynchronous brake motors LS FCR. General information
General information LIFTING USE : U.L. Enclosed three-phase asynchronous brake motors, LS series with failsafe brake, according to IEC 34, 72, EN 50281. Single speed : 0.55 to 15, frame size from 80 to
More informationINSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00
INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25
More informationCONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances
CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding 4.4
More information87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS
87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084
More informationNEXT STEP B) SAFETY :
SUMMARY : EVOLUTION OF MV/LV SUBSTATIONS COMPACT SUBSTATIONS J. M. Solans, C. Prevé, R. Farrán, R. Muñoz. SCHNEIDER ELECTRIC S.A. - SPAIN INTRODUCTION The recent liberalisation of the electricity supply
More informationProducts & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)
630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup
More informationMESG 12 / 17.5 / 24 / 36 KV
MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL
More informationAFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED
More informationSurge-Trap Pluggable STPT2 Series - 40kA
Surge-Trap Pluggable STPT2 Series - 40kA SURGE PROTECTION FOR POWER LINES DIN-RAIL IEC TYPE 2 / CLASS II FEATURES & BENEFITS Maximum discharge current (8/20μs): 40kA per phase Nominal discharge current
More information36.02 /// THREE-PHASE TRANSFORMERS
36.02 /// THR-PHS TRNSFORMRS www.meth.it 36.01 /// 23 T3TULF-T3TUL LV three-phase GNRL PURPOS transformers UL-S marked up to 25 kv Three-phase transformer T3TULF-T3TUL Technical data T3TULF - T3TUL O RT
More informationLSN Atmospheres containing explosive GAS totally enclosed three-phase asynchronous motors General information
General information Non-sparking totally enclosed threephase asynchronous motors, LSN series, according to IEC 60034, 60072, IEC 60079-1 and 60079-15. Single speed: power 0.75 to 90 kw 1, frame size 80
More information2. INDUCTIVE VOLTAGE TRANSFORMERS Dry and oil-paper insulation
2. INDUCTIVE VOLTGE TRNSFORMERS Dry and oil-paper insulation 12 Instrument transformers Outdoor medium voltage 2. INDUCTIVE VOLTGE TRNSFORMERS > Dry and oil-paper insulation INTRODUCTION Inductive voltage
More informationIndustrial Control Transformers
The SBE - Encapsulated, Copper Wound Series The SolaHD SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants.
More informationIssue Title Remarks. Instrument transformers See IEC 61869
357 Appendix Norms and Standards As far as norms and standards are mentioned in this book, the respective citation of IEC or DIN EN is given. If IEC-standards or DIN EN-norms are not available, the European
More informationSolar Power Switchgear & Energy Storage Renewable Energy Systems
7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH
More informationDesign specifications
Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor
More informationBharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT
An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY Phone: +91 431 257 79 38 Fax
More informationCast Resin Transformers
Cast Resin Transformers Since their appearance and introduction in the electric market, Cast Resin Transformers (CRT) have won an important position in every sector due to: The use of special epoxy self-extinguishing
More informationMedium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU
Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationVacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.
Vacuum Cast Coil Dry Type Distribution Transformers The reliability in your hands. ABB Vacuum Cast Coil dry transfomera leader in its category In almost every place where people live and work you will
More informationDC/DC converters - MINI-PS DC/ 5-15DC/
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationMarcel Fortin ing. Hydro Québec Distribution 1
1 The extrapolation to zero time of the windings average temperature after a heat run test is of prime importance in qualifying a transformer. In order to have correct extrapolation we need: Correct measurement
More information