Operating Instructions. Excellence Comparator Balances XP-K Models Part 1

Size: px
Start display at page:

Download "Operating Instructions. Excellence Comparator Balances XP-K Models Part 1"

Transcription

1 Operating Instructions Excellence Comparator Balances XP-K Models Part 1

2

3 Table of Contents 1 Introduction Symbols and presentations used 6 2 Safety Information Definition of signal warnings and symbols Product specific safety notes 7 3 Overview XP-K Comparators 9 4 Installation and Putting into Operation Unpacking and checking the standard equipment Scope of delivery Selecting the location and level of the balance Location Leveling the balance Unblocking and assembling the balance Installing the balance cable in the terminal Placing the terminal Connecting the balance Setting the reading angle Transporting the balance 14 5 Special Settings for Comparators Load the balance Settings for the balances 15 6 Maintenance Cleaning Disposal 16 7 Technical Data General data Explanatory notes for the METTLER TOLEDO AC adapter Model-specific data Dimensions Dimensions XP155KS Dimensions XP604KM, XP1003KM Dimensions XP2003KL, XP6002KL Dimensions Terminal Interfaces Specifications of RS232C 24 8 Accessories and Spare Parts Accessories Spare parts 29 9 Appendix MT-SICS interface commands and functions 30 Index 31 Table of Contents 3

4

5 1 Introduction Thank you for choosing a METTLER TOLEDO balance. In this chapter you will be given basic information about your balance. Please read right through this chapter carefully even if you already have experience with METTLER TOLEDO balances. Please pay special attention to the safety warnings! The different models have different characteristics regarding equipment and performance. Special notes in the text indicate where this makes a difference to operation. The XP line comprises a range of balances which differ from each other in relation to their weighing range and resolution. The following features are common to all models of the XP lines: Fully automatic adjustment "ProFACT" using internal weights. Built-in applications for WeighCom, normal weighing, statistics, formulation, piece counting, percent weighing, density, differential weighing, and LabX Client. Integral RS232C interface. Touch-sensitive graphics terminal ("Touch screen") with color display. Two programmable sensors for hands-off operation ("SmartSens") to speed up frequently recurring tasks. A brief word about standards, guidelines, and methods of quality assurance: The balances comply with usual standards and guidelines. They support standard procedures, specifications, working methods, and reports according to GLP (Good Laboratory Practice). In this connection, records of working procedures and adjustments become very important; for this purpose we recommend you to use a printer from the METTLER TOLEDO range, since these are optimally adapted to your balance. The balances conform to the applicable standards and guidelines and possess a EC declaration of conformity. METTLER TOLEDO is certified as manufacturer according to ISO 9001 and ISO The operating instructions for the XP balances consist of 4 separate documents, whose contents are listed below. Part 1, this document Contents Introduction Safety Information Installation and Putting into Operation (performed by a service technician from METTLER TOLEDO) Special Settings for XP-K Comparators Cleaning and Service Technical Data Accessories Spare Parts Interface Commands and MT-SICS Functions Part 2, separate document Contents: Terminal, System, and Applications Basic Principles for Using the Terminal and the Firmware System Settings User-specific Settings Applications Firmware (Software) Updates Error and Status Messages Introduction 5

6 Conversion Table for Weight Units Recommended Printer Settings Part 3, separate document Contents: Adjustments, and Tests Adjustments Tests Operating Instructions "WeighCom Application for XP Comparator Balances" When working with the [WeighCom] application, use the operating instructions "WeighCom Application for XP Comparator Balances" that were included with the delivery. Finding more information u Firmware version The operating instructions are based on the initially installed terminal firmware (software) version V Symbols and presentations used The following conventions apply to the operating instructions: part 1, part 2, part 3 and WeighCom application for XP comparator balances. Key designations are indicated by a picture or text in double angular parentheses (e.g. or «On/Off»). 1 2 These symbols indicate an instruction: prerequisites steps results 6 Introduction

7 2 Safety Information 2.1 Definition of signal warnings and symbols Safety notes are marked with signal words and warning symbols. These show safety issues and warnings. Ignoring the safety notes may lead to personal injury, damage to the balance, malfunctions and false results. Signal words WARNING CAUTION Attention Note for a hazardous situation with medium risk, possibly resulting in severe injuries or death if not avoided. for a hazardous situation with low risk, resulting in damage to the device or the property or in loss of data or minor or medium injuries if not avoided. (no symbol) for important information about the product. (no symbol) for useful information about the product. Warning symbols General hazard Electrical shock Heavy object Mandatory safety signs Wear gloves 2.2 Product specific safety notes Intended use Your balance is used for weighing. Use the balance exclusively for this purpose. Any other type of use and operation beyond the limits of technical specifications without written consent from Mettler-Toledo AG, is considered as not intended. It is not permitted to use the instrument in explosive atmosphere of gases, steam, fog, dust and flammable dust (hazardous environments). General safety information Your instrument meets the state of the art technology and complies with all recognized safety rules, however, certain hazards may arise in extraneous circumstances. Do not open the housing of the instrument: It does not contain any parts which can be maintained, repaired or replaced by the user. If you ever have problems with your instrument, contact your authorized METTLER TOLEDO dealer or service representative. Always operate and use your balance only in accordance with the operating instructions part 1, part 2, part 3 and WeighCom application for XP comparator balances. The instructions for setting up your new balance must be strictly observed. Safety Information 7

8 If the instrument is not used according to the manufacturer s operating instructions (part 1, part 2, part 3 and WeighCom application for XP comparator balances), protection of the instrument may be impaired. Staff safety In order to use the instrument, you must have read and understood the operating instructions. Keep the operating instructions for further reference. Never make any modifications to the instrument and use only original spare parts and optional equipment from METTLER TOLEDO. Safety notes WARNING Risk of electric shock Use only the original universal AC adapter delivered with your balance, and check that the voltage printed on it is the same as your local power supply voltage. Only plug the adapter into a socket which is grounded. WARNING Heavy object Single person lift could cause injury. Do not move or lift this equipment without assistance. For moving this equipment ask your METTLER TOLEDO representative. CAUTION Damage of device For use only in dry interior rooms. Do not use sharply pointed objects to operate the keyboard! Although your balance is very ruggedly constructed, it is nevertheless a precision instrument. Treat it with corresponding care. Do not open the balance: It does not contain any parts which can be maintained, repaired, or replaced by the user. If you ever have problems with your balance, contact your METTLER TOLEDO dealer. Use only balance accessories and peripheral devices from METTLER TOLEDO; they are optimally adapted to your balance. 8 Safety Information

9 F F 3 Overview XP-K Comparators Overview XP-K Terminal (details see Operating Instruction Part 2) 2 Display (Touch-sensitive "Touch screen") 3 Operating keys 4 SmartSens sensors 5 Type name 6 Level indicator 7 Centering aid 8 Weighing pan 9 Foot screws 10 Connector for terminal cable 11 RS232C serial interface 12 Socket for AC adapter Overview XP-K Comparators 9

10 4 Installation and Putting into Operation WARNING Risk of electric shock The balance must be disconnected from the power supply before any set-up or installation work, as well as when the housing of the weighing terminal is opened. 4.1 Unpacking and checking the standard equipment Open the packaging and carefully remove all components. 4.2 Scope of delivery Weighing platform RS232C interface Terminal with wall fixture and protective cover Terminal extension cable, length = 5 m AC adapter with country-specific power cable Production certificate CE declaration of conformity Operating instructions part 1 (this document), part 2, part 3 and WeighCom application for XP comparator balances 4.3 Selecting the location and level of the balance Location An optimal location will ensure accurate and reliable operation of the balance. The surface must be able to safely take the weight of the balance when fully loaded. The following local conditions must be observed: Note If the balance is not horizontal at the outset, it must be leveled during commissioning. The balance must only be used indoors and up to a maximum altitude of 4000 m above sea level. Before switching on the balance, wait until all parts are at room temperature (+10 to 30 C). The humidity must be between 10% and 80% non-condensing. The power plug must be accessible at all times. Firm, horizontal and vibration-free location. Avoid direct sunlight. No excessive temperature fluctuations. No strong drafts. Further information can by found in Weighing the Right Way. 10 Overview XP-K Comparators

11 4.3.2 Leveling the balance Note If the balance is not horizontal from the beginning, it will have to be leveled during initial operation. XP155KS, XP604KM, XP1003KM 1 Level the weighing platform by turning the 4 leveling screws (1). 2 Ensure that the leveling screws all sit flat on the floor evenly. 3 Test the stability of the weighing platform by pressing down on or rocking the corners. The level is correct when the air bubble lies in the center of the level indicator (2). 2 1 XP2003KL, XP6002KL 1 Level the weighing platform by turning the 4 leveling screws (1). 2 The leveling screws can be adjusted with a size 30 engineer s wrench. 3 Ensure that the leveling screws all sit flat on the floor evenly. 4 Test the stability of the weighing platform by pressing down on or rocking the corners. The level is correct when the air bubble lies in the center of the level indicator (2) Unblocking and assembling the balance Note Your new balance will be assembled and unblocked by a METTLER TOLEDO service technician Installing the balance cable in the terminal Ensure that a soft, clean surface is used so as not to damage the terminal surface Place the terminal on the operating surface. 2 Open the housing by pressing the 2 buttons (1) for adjusting the terminal and swiveling the housing base upwards. 3 Pull the cable with the retaining ring (2) through the opening on the housing base. 4 Return the terminal to its normal position. 2 Installation and Putting into Operation 11

12 5 Open it so that the cable can be accessed. 6 Insert the cable (3) into the top housing. 7 Close both parts of the housing until the retaining ring (2) is positioned in the cable opening of the housing base. 8 Place the retaining ring (2) behind the two guideways and check that it is secure (tension relief). 9 Before closing the housing, check that the plug is inserted correctly into the terminal plug-in connection. 10 Now close the housing by pressing the two buttons (1) for adjusting the terminal until the housing base engages in the top housing Placing the terminal The terminal can either stand freely or be attached to the wall using a wall fixture. 4.5 Connecting the balance WARNING Risk of electric shock a) To connect the balance, only use the supplied three-core power cord with equipment grounding conductor. b) Only connect the balance to a three-pin power socket with earthing contact. c) Only standardized extension cable with equipment grounding conductor must be used for operation of the balance. d) Intentional disconnection of the equipment grounding conductor is forbidden. The balance is supplied with an AC adapter and country-specific power cable. The AC adapter is suitable for use with the following voltage range: 12 Installation and Putting into Operation

13 V AC, 50/60 Hz. Attention Check whether your local power supply falls within this range. If this is not the case, under no circumstances connect the AC adapter to the power supply, but contact a METTLER TOLEDO representative. The power plug must be accessible at all times. Prior to use, check the power cord for damage. Route the cable in such a way that it cannot be damaged or cause a hindrance when working. Ensure that no liquid comes into contact with the AC adapter. Balance and terminal are at the final location. 1 Connect the AC adapter (1) to the connection socket (2) at the rear of the balance. 2 Connect the AC adapter (1) to the power supply. The balance performs a self-test after connection to the power supply and is then ready to use. 2 1 Note If the display field remains dark, even though the power supply connection functions First disconnect the balance from the power supply. 2 Open the terminal. 3 Press both buttons (3) on the back of the terminal and open the upper part of the terminal. 4 Check that the plug for the terminal cable (4) is connected correctly inside the terminal. 4.6 Setting the reading angle 1 Press in the two buttons (1) on the back of the terminal. The top of the terminal can then be pulled up or pushed down until it engages in the desired position. A total of 3 setting positions are available. 2 Move it in an appropriate position. 1 1 Installation and Putting into Operation 13

14 4.7 Transporting the balance Note If you wish to change the location, please contact your METTLER TOLEDO dealer. 14 Installation and Putting into Operation

15 5 Special Settings for Comparators To fully utilize the high resolution of the balance, some specific rules must be observed. These will enable you to obtain the best possible results. 5.1 Load the balance Because of the high resolution of the balance, even minute differences of temperature or humidity can affect the result. Make sure that the weighing pan are clean and that the weighing sample is acclimatized. CAUTION Use gloves or working aids when loading and unloading the balance Otherwise artifacts may be damaged. Use aids (e.g. crane) with a maximum speed of 5 mm/sec. for loading the balance. A higher speed can have negative influences on the weighing result. 5.2 Settings for the balances AutoZero ProFACT Is switched off at initial operation and after a factory reset (resetting to the factory settings), but can be switched on again when required. When changing over to the "WeighCom" application, AutoZero is automatically switched off. When changing back to the "Weigh" application, the previous status of «AutoZero» is restored. Attention When comparing masses, AutoZero must not be switched on, because it can distort the measurement values. Is switched off at initial operation and after a factory reset (resetting to the factory settings). When comparing masses, it is not advisable to switch ProFACT on. Special Settings for Comparators 15

16 6 Maintenance 6.1 Cleaning Periodically clean the weighing pan, housing and terminal of your balance using a damp cloth. The maintenance interval depends on your standard operating procedure (SOP). Please observe the following notes WARNING Risk of electric shock a) Disconnect the balance from the power supply prior to cleaning and maintenance. b) Only use METTLER TOLEDO power cable, if these need to be replaced. c) Ensure that no liquid comes into contact with the balance, terminal or AC adapter. d) Do not open the balance, terminal or AC adapter. These contain no user-serviceable parts. Cleaning 6.2 Disposal CAUTION Damage of balance On no account use cleaning agents which contain solvents or abrasive ingredients, as this can result in damage to the terminal overlay. Your balance is made from high quality, resistant materials and can therefore be cleaned with a commercially available, mild cleaning agent. Note Please contact your METTLER TOLEDO dealer for details of the available service options. Regular servicing by an authorized service engineer ensures constant accuracy for years to come and prolongs the service life of your balance. In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection. 16 Special Settings for Comparators

17 7 Technical Data 7.1 General data CAUTION Use only with a tested AC Adapter with SELV output current. Ensure correct polarity Power supply AC adapter: Cable for AC adapter: Balance power supply: Primary: V AC, -15%/+10%, 50/60 Hz Secondary: 12 V DC ±3%, 2.5 A (with electronic overload protection) 3-core, with country-specific plug 12 V DC ±3%, 2.25 A, maximum ripple: 80 mvpp Protection and standards Overvoltage category: II Degree of pollution: 2 Protection: IP44, protected against dust and water Standards for safety and EMC: See Declaration of Conformity Range of application: For use only in closed interior rooms Environmental conditions Height above mean sea level: Ambient temperature: Relative air humidity: Maximum air speed: Maximum loading speed: Materials Weighing platform: Terminal: Weighing pan: Up to 4000 m C ±0.7 C / 1 h, or ±1.0 C / 12 h respectively 40 up to 70% ±10% / 4 h 0.20 m/sec 5 mm/sec XP155KS, XP604KM, XP1003KM: Chrome steel X5CrNi18-10, laquered and plastic XP2003KL, XP6002KL: Galvanized steel S235JR+AR, laquered and plastic Die-cast zinc, chromed and plastic Chrome steel X6Cr Explanatory notes for the METTLER TOLEDO AC adapter The certified external power supply which conforms to the requirements for Class II double insulated equipment is not provided with a protective earth connection but with a functional earth connection for EMC purposes. This earth connection IS NOT a safety feature. Further information about conformance of our products can be found in the brochure "Declaration of Conformity" which is coming with each product. In case of testing with regard to the European Directive 2001/95/EC the power supply and the balance have to be handled as Class II double insulated equipment. Consequently an earth bonding test is not required. Similarly it is not necessary to carry out an earth bonding test between the supply earth conductor and any exposed metalwork on the balance. Because the balance are sensitive to static charges a leakage resistor, typically 10 kω, is connected between the earth connector and the power supply output terminals. The arrangement is shown in the equivalent circuit Technical Data 17

18 diagram. This resistor is not part of the electrical safety arrangement and does not require testing at regular intervals. Plastic Housing Double Insulation P AC Input VAC Output 12 VDC N DC 10 kω coupling resistor for electrostatic discharge E Equivalent circuit diagram 7.3 Model-specific data XP155KS XP604KM XP1003KM Limit values Maximum capacity 150 kg 600 kg 1100 kg Readability 0.05 g 0.1 g 0.5 g Tare range (from to) kg kg kg Repeatability (at nominal load) sd 0.15 g (100 kg) 0.3 g (500 kg) 2 g (1000 kg) Repeatability (at low load) sd 0.15 g (5 kg) 0.3 g (20 kg) 2 g (50 kg) Repeatability (at nominal load) (ABA, measured sd 0.12 g (100 kg) 0.23 g (500 kg) 1.5 g (1000 kg) at) 2) Repeatability (at low load) (ABA, measured at) 2) sd 0.09 g (5 kg) 0.15 g (20 kg) 1 g (50 kg) Linearity deviation 2 g 10 g 20 g Eccentricity deviation (test load) 5 g (50 kg) 40 g (200 kg) 40 g (500 kg) Sensitivity offset (test weight) 0.1 g (100 kg) 5 g (500 kg) 10 g (1000 kg) Sensitivity temperature drift 1) %/ C %/ C %/ C Sensitivity stability %/a Rnt %/a %/a Typical values Repeatability (at low load) 2) sd g (100 kg) 0.22 g (500 kg) 1.3 g (1000 kg) Repeatability ABA 2) sd 0.09 g (100 kg) 0.18 g (500 kg) 1 g (1000 kg) Linearity deviation 1.2 g 6 g 12 g Eccentric deviation (test load) 3 g (50 kg) 22 g (200 kg) 22 g (500 kg) Sensitivity offset (test weight) 0.02 g (100 kg) 1 g (500 kg) 2 g (1000 kg) Minimum weight (according to USP) 0.24 kg 0.42 kg 3 kg Minimum weight (U=1%, k=2) kg kg 0.2 kg Settling time 5 s 5 s 5 s Dimensions Balance dimensions (W D H) mm mm mm Weighing pan dimensions mm (W D) mm (W D) Typical uncertainties and supplementary data Repeatability 2) sd 0.08 g % Rgr Repeatability (ABA, measured at) 2) sd 0.06 g % Rgr 0.14 g % Rgr 0.11 g % Rgr mm (W D) 1 g % Rgr 0.6 g % Rgr Differential linearity deviation sd g Rnt 0.06 g Rnt 0.13 g Rnt Differential eccentric load deviation sd 0.006% Rnt 0.011% Rnt % Rnt Sensitivity offset sd % Rnt % Rnt % Rnt Minimum weight (according to USP) 0.24 kg % Rgr 0.42 kg % Rgr 3 kg % Rgr 18 Technical Data

19 XP155KS XP604KM XP1003KM Minimum weight (U=1%, k=2) kg % Rgr kg % Rgr 0.2 kg % Rgr Weighing time 1 ABA 3) s s s Interface update rate 23 /s 23 /s 23 /s Weight of balance 54 kg 93 kg 93 kg Number of built-in reference weights Weights for routine testing OIML CarePac 5 kg M1 20 kg M1 50 kg M1 # # # Weights 100 kg M1 # kg M1 # kg M1 # ASTM CarePac Weights 5 kg ASTM 2 # kg ASTM 2 # kg ASTM 2 # kg ASTM 2 # kg ASTM 2 # kg ASTM 2 # sd = Standard deviation Rnt = Net weight (sample weight) Rgr = Gross weight a = Year (annum) 1) In the temperature range C 2) Value out of 5 ABA measurements according to OIML R111 3) Unloading/Loading: 0 10 kg = 6 s, kg = 15 s, kg = 35 s XP2003KL XP6002KL Limit values Maximum capacity 2500 kg 5400 kg Readability 1 g 10 g Tare range (from to) kg kg Repeatability (at nominal load) sd 10 g (2000 kg) 100 g (5000 kg) Repeatability (at low load) sd 10 g (100 kg) 100 g (200 kg) Repeatability (at nominal load) (ABA, measured sd 7 g (2000 kg) 70 g (5000 kg) at) 2) Repeatability (at low load) (ABA, measured at) 2) sd 4 g (100 kg) 50 g (500 kg) Linearity deviation 100 g 300 g Eccentricity deviation (test load) 120 g (1000 kg) 240 g (2000 kg) Sensitivity offset (test weight) 20 g (2000 kg) 50 g (5000 kg) Sensitivity temperature drift 1) %/ C %/ C Sensitivity stability %/a %/a Typical values Repeatability (at low load) 2) sd 7 g (2000 kg) 70 g (5000 kg) Repeatability ABA 2) sd 5.5 g (2000 kg) 60 g (5000 kg) Linearity deviation 60 g 220 g Eccentric deviation (test load) 33 g (1000 kg) 80 g (2000 kg) Sensitivity offset (test weight) 6 g (2000 kg) 15 g (5000 kg) Minimum weight (according to USP) 12.6 kg 126 kg Minimum weight (U=1%, k=2) 0.84 kg 8.4 kg Settling time 5 s 5 s Dimensions Balance dimensions (W D H) mm Weighing pan dimensions mm (W D) mm mm (W D) Typical uncertainties and supplementary data Repeatability 2) sd 4.2 g % Rgr 42 g % Rgr Repeatability (ABA, measured at) 2) sd 3 g % Rgr 40 g % Rgr Differential linearity deviation sd 1.4 g Rnt 9 g Rnt Differential eccentric load deviation sd % Rnt 0.004% Rnt Technical Data 19

20 XP2003KL XP6002KL Sensitivity offset sd % Rnt % Rnt Minimum weight (according to USP) 12.6 kg % Rgr 126 kg % Rgr Minimum weight (U=1%, k=2) 0.84 kg % Rgr 8.4 kg % Rgr Weighing time 1 ABA 3) s s Interface update rate 23 /s 23 /s Weight of balance 382 kg 382 kg Number of built-in reference weights 2 2 Weights for routine testing OIML CarePac 100 kg M1 200 kg M1 # # Weights 2000 kg M1 # kg M1 # ASTM CarePac Weights 100 kg ASTM 2 # kg ASTM 2 # kg ASTM 2 # kg ASTM 2 #Please inquire sd = Standard deviation Rnt = Net weight (sample weight) Rgr = Gross weight a = Year (annum) 1) In the temperature range C 2) Value out of 5 ABA measurements according to OIML R111 3) Unloading/Loading: 0 10 kg = 6 s, kg = 15 s, kg = 35 s 20 Technical Data

21 7.4 Dimensions Dimensions XP155KS Dimensions in mm FS ø H L L Model: XP155KS FS H L Leveling screw Footprint D Size Height adjustable with 4 leveling screws Min. Max. Level indicator ø 35 mm 17 mm 130 mm 155 mm Technical Data 21

22 7.4.2 Dimensions XP604KM, XP1003KM Dimensions in mm ø H FS FS L Models: XP604KM, XP1003KM FS H L Leveling screw Footprint D Size Height adjustable with 4 leveling screws Min. Max. Level indicator ø 40 mm 19 mm 115 mm 140 mm 22 Technical Data

23 7.4.3 Dimensions XP2003KL, XP6002KL Dimensions in mm H G D L FS Models: XP2003KL, XP6002KL L FS H L Leveling screw Footprint D Size Height adjustable with 4 leveling screws Min. Max. Level indicator mm 30 mm 182 mm 207 mm Technical Data 23

24 7.4.4 Dimensions Terminal Dimensions in mm Terminal 7.5 Interfaces Specifications of RS232C Interface type: Max. cable length: Signal level: Connector: Operating mode: Transmission mode: Transmission code: Baud rates: Bits/parity: Stop bits: Handshake: End-of-line: GND Data Handshake Voltage interface according to EIA RS-232C/DIN (CCITT V24/V.28) 15 m Outputs: Inputs: +5 V V (RL = 3 7 kω) +3 V V 5 V V (RL = 3 7 kω) 3 V V Sub-D, 9-pole, female Full duplex Bit-serial, asynchronous ASCII 600, 1200, 2400, 4800, 9600, 19200, ) (firmware selectable) 7-bit/even, 7-bit/odd, 7-bit/none, 8-bit/none (firmware selectable) 1 stop bit None, XON/XOFF, RTS/CTS (firmware selectable) <CR><LF>, <CR>, <LF> (firmware selectable) Pin 2: Balance transmit line (TxD) Pin 3: Balance receive line (RxD) Pin 5: Ground signal (GND) Pin 7: Clear to send (hardware handshake) (CTS) Pin 8: Request to send (hardware handshake) (RTS) 1) baud is only possible in special cases, such as: Weighing platform without terminal, or Weighing platform with terminal, only via the optional RS232C interface. 24 Technical Data

25 8.003 g g g g g g g g g g g g 8 Accessories and Spare Parts 8.1 Accessories You can increase the functionality of your balance with accessories from the METTLER TOLEDO range. The following options are available: Description Part No. Printers Printer g g g g METTLER TOLEDO BT-P42 printer with Bluetooth connection to instrument Paper roll, set of 5 pcs Paper roll, self-adhesive, set of 3 pcs Ribbon cartridge, black, set of 2 pcs Printer g g g g METTLER TOLEDO RS-P42 printer with RS232C connection to instrument Paper roll, set of 5 pcs Paper roll, self-adhesive, set of 3 pcs Ribbon cartridge, black, set of 2 pcs Cables for RS232C interface RS9 RS9 (m/f): connection cable for PC, length = 1 m RS9 RS25 (m/f): connection cable for PC, length = 2 m Auxiliary displays LC/RS-BLD auxiliary display on bench stand, backlit (incl. RS cable and separate AC adapter) RS/LC-BLDS auxiliary display for table or balance mounting, 480 mm, LCD display with backlighting Accessories and Spare Parts 25

26 LC-AD auxiliary display, active, with table stand LC-ADS auxiliary display, active, with high table stand Terminal IND690, bench model Barcode reader RS232C Barcode Reader The following accessories are needed for operation (not included): RS232 F cable Null modem adapter Plus one of the following: AC adapter 5 V for EU AC adapter 5 V for US AC adapter 5 V for GB AC adapter 5 V for AU RS232C Barcode Reader Cordless The following accessories are needed for operation (not included): Cradle RS232 F cable Null modem adapter Plus one of the following: AC adapter 12 V for EU AC adapter 12 V for US AC adapter 12 V for GB AC adapter 12 V for AU PS/2 Barcode Reader, without cable PS/2 wedge single cable Accessories and Spare Parts

27 PS/2Y Barcode Reader, without cable PS/2 wedge twin (Y) cable Protective covers Protective cover for XP terminal Software MCLink LabX software for one click weighing solutions Enables you to perform One Click Standard Preparation, One Click Loss on Drying, One Click Sieve Analysis and many other applications. Simply start the method with the One Click shortcut on the balance touchscreen. LabX guides you step-by-step through the SOP on the balance, performs your calculations automatically, and takes care of saving all your data. The complete solution can be tailored to match your process requirements. Visit for more information MCLink mass comparator control software MCLink software a simple and practical tool for carrying out your mass measurements to a high level of efficiency. MCLink is the ideal tool for facilities from small calibration laboratories up to scientific mass laboratories Reports are generated safely end efficient with direct control of the comparators with one click. on request Draft shields Draft shield XP-WKS for KS models Draft shield XP-WKM for KM models Draft shield XP-WKL for KL models Accessories and Spare Parts 27

28 LevelMatic LevelMatic 1000 for XP155KS and XP604KM LevelMatic 5000 for XP1003KM, XP2003KL and XP6002KL Reference weights Reference weight, 100 kg (E1), certified Please inquire Reference weight, 200 kg (E1), certified Please inquire Reference weight, 500 kg (E1), certified Please inquire Reference weight, 1000 kg (E1), certified Please inquire Reference weight, 2000 kg (E2), certified Please inquire Reference weight, 5000 kg (E2), certified Please inquire 28 Accessories and Spare Parts

29 Various AC/DC adapter (without power cable) V AC, 0.8 A, 50/60 Hz, 12 V DC 2.5 A Country-specific 3-Pin power cable with grounding conductor. Power cable AU Power cable BR Power cable CH Power cable CN Power cable DK Power cable EU Power cable GB Power cable IL Power cable IN Power cable IT Power cable JP Power cable TH, PE Power cable US Power cable ZA Spare parts Pos Description Part No. XP Terminal complete with firmware F METTLER TOLEDO F Accessories and Spare Parts 29

30 9 Appendix 9.1 MT-SICS interface commands and functions Many of the instruments and balances used have to be capable of integration in a complex computer or data acquisition system. To enable you to integrate balances in your system in a simple manner and utilize their capabilities to the full, most balance functions are also available as appropriate commands via the data interface. All new METTLER TOLEDO balances launched on the market support the standardized command set "METTLER TOLEDO Standard Interface Command Set" (MT-SICS). The commands available depending on the functionality of the balance. For further information please refer to the Reference Manual MT-SICS downloadable from the Internet under u 30 Accessories and Spare Parts

31 Index A B AC adapter 13, 17, 17 Accessories 25 Balance cable 11 T Setting the reading angle 13 Settings 15 Staff safety 8 Technical data 17 Terminal 11 C Cleaning 16 Connecting the balance 13 Connecting to power supply 13 Conventions 6 D Dimensions 21 Display field remains dark 13 Disposal 16 E Environmental conditions 17 F Features 5 G General safety information 7 GLP 5 Good Laboratory Practice 5 I Interface MT-SICS 30 ISO ISO L Load the balance 15 Local conditions 10 Location 10 M Materials 17 MT-SICS 30 P Power cable 12 Power supply 17 Power supply voltage 12 Protection and standards 17 R RS232C interface 24 S Safety information 7, 7 Staff safety 8 Self-test 13 Index 31

32

33

34 For more information Mettler-Toledo AG, Laboratory Weighing CH-8606 Greifensee, Switzerland Tel. +41 (0) Fax +41 (0) Subject to technical changes. Mettler-Toledo AG 01/ B en * *

Operating Instructions

Operating Instructions F F F F F F F F F F Operating Instructions METTLER TOLEDO Excellence Plus Precision Balances XP Models - Part 1 METTLER TOLEDO METTLER TOLEDO Table of contents 1 Introduction 5 1.1 Conventions and Symbols

More information

METTLER TOLEDO XP56/XP26/XP505 Comparators. Supplementary Instructions to the Operating Instructions for XP Analytical Balances

METTLER TOLEDO XP56/XP26/XP505 Comparators. Supplementary Instructions to the Operating Instructions for XP Analytical Balances METTLER TOLEDO XP56/XP26/XP505 Comparators Supplementary Instructions to the Operating Instructions for XP Analytical Balances Overview of your XP56/XP26 comparator 5 8 6 www.mt.com 7 15 14 5 12 F 3 4

More information

Automated Precision Weighing

Automated Precision Weighing Automated Precision Weighing Designed for Automation Compact Precision Weighing High precision Designed to meet the most demanding customer specifications. The WMS is a high speed high accuracy weigh module

More information

Automated Precision Weighing

Automated Precision Weighing Automated Precision Weighing Designed for Automation in Hazardous Environment, Zone 2 High Precision Designed to meet the most demanding customer specifications. The WMS is a high speed high accuracy weigh

More information

Quick Guide. brite Advanced Retail scale

Quick Guide. brite Advanced Retail scale Quick Guide brite Advanced Retail scale 2 METTLER TOLEDO Quick Guide brite Advanced Contents 1 Your new retail scale...4 1.1 Safety instructions...4 1.2 Further documents...4 1.3 Maintenance...4 1.4 Intended

More information

Excellence Level. XPR Precision Balances Accurate, Flexible, Compliant. XPR Precision Balance Solutions Go Beyond Weighing

Excellence Level. XPR Precision Balances Accurate, Flexible, Compliant. XPR Precision Balance Solutions Go Beyond Weighing Excellence Level XPR Precision Balances Accurate, Flexible, Compliant Outstanding Performance The weighing pan minimizes the effects of air currents on the weighing cell to deliver faster and more accurate

More information

Security Knows No Alternative. Excellence Plus XP High performance analytical balances. - Data security - Sample security - User safety

Security Knows No Alternative. Excellence Plus XP High performance analytical balances. - Data security - Sample security - User safety Excellence Plus XP High performance analytical balances - Data security - Sample security - User safety That s the weigh! Security Knows No Alternative Excellence Plus XP: High performance analytical balances

More information

The ML-T Balance Line Reliable results Easy operation Compact and convenient. Big Features Go Compact Worry-free Weighing

The ML-T Balance Line Reliable results Easy operation Compact and convenient. Big Features Go Compact Worry-free Weighing ML-T Balances The ML-T Balance Line Reliable results Easy operation Compact and convenient Big Features Go Compact Worry-free Weighing Reliable Results ML-T Balances Results You Can Rely On With ever-increasing

More information

Excellence Balances. Excellence Plus XP High-performance Micro and Analytical balances from METTLER TOLEDO. Comprehensive Security Has no Alternative

Excellence Balances. Excellence Plus XP High-performance Micro and Analytical balances from METTLER TOLEDO. Comprehensive Security Has no Alternative Excellence Balances Excellence Plus XP High-performance Micro and Analytical balances from METTLER TOLEDO Comprehensive Security Has no Alternative Excellence Plus XP We Understand Your Safety Concerns

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

Defender 3000 Series Base Instruction Manual

Defender 3000 Series Base Instruction Manual Defender 3000 Series Base Instruction Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Compliance This product conforms to

More information

SSP-Series Portable Balances Operation Manual

SSP-Series Portable Balances Operation Manual SSP-Series Portable Balances Operation Manual TABLE OF CONTENTS SAFETY PRECAUTIONS.. 1 GETTING STARED... 1 INSTALLATION & SET-UP 2 POWER CONNECTION & BATTERY OPERATION... 2 LEVELING... 3 CALIBRATION...

More information

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002 Adam Equipment QT SERIES ADAM EQUIPMENT CO. LTD. pn. 3938 Rev. D1, July 2002 Adam Equipment Co. Ltd. 2002 Adam Equipment Co. Ltd. 2002 FEATURES Auto shut off Auto zero tracking Auto backlight (optional)

More information

MAS, MAS.1 weighing modules

MAS, MAS.1 weighing modules MAS, MAS.1 weighing modules Series of professional electromagnetic modules of high resolution ensures highly precise and fast measurement in laboratory. MAS.1.Y MAS.1.R MAS.1 MAS Features High Resolution

More information

Operating instructions Platform/floor scales

Operating instructions Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating instructions Platform/floor scales KERN

More information

Compact Scales. Software Revision V1.25 & above

Compact Scales. Software Revision V1.25 & above Compact Scales Software Revision V1.25 & above 2016 1 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when power is first turned on): Date of Purchase:

More information

Operating manual Platform/floor scales

Operating manual Platform/floor scales KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Operating manual Platform/floor scales KERN / / EOS Type _B Type _B Type EOS_B Version 4.1 2017-04 GB Phone: +49-[0]7433-9933-0 Fax:

More information

OVERVIEW OF CONTROLS

OVERVIEW OF CONTROLS π H-5819, H-5820 H-5821, H-5822 DELUXE COUNTING SCALE 1-800-295-5510 uline.com OVERVIEW OF CONTROLS DISPLAY DEFINITIONS # NAME DESCRIPTION 1 DISPLAY 2 1 3 STABLE 4 RECHARGE PAGE 1 OF 8 Displays the total

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

Mass Comparators Advanced Radwag solutions for traceability of measurement

Mass Comparators Advanced Radwag solutions for traceability of measurement Mass Comparators Advanced Radwag solutions for traceability of measurement Automatic Mass Comparators COMPARISON OF 1 mg 1000 g WEIGHTS OF CLASS E1, E2, F1, F2, M1 AND M2 Automatic Mass Comparators UMA

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS

More information

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing Excellence Level XSR Balances Robust performance Maximum productivity Ergonomic operation Excellence XSR Balances Discover Efficiency in Daily Weighing XSR Balances XSR Balances Fast and Accurate Results

More information

EPS/ELA-Series User Manual EPS/ELA 250W

EPS/ELA-Series User Manual EPS/ELA 250W EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...

More information

SPG-DIGI. Operating Instruction. Please read carefully before use!

SPG-DIGI. Operating Instruction. Please read carefully before use! WALTER STAUFFENBERG GMBH & CO.KG Im Ehrenfeld 4 D-58791 Werdohl Postfach 1745 D-58777 Werdohl Germany Tel.: +49 (0) 2392 / 916-0 Fax: +49 (0) 2392 / 2505 E-Mail: sales@stauff.com Internet: www.stauff.com

More information

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS NGW & HGW SERIES HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE CONTENTS CAUTIONS 1. INSTALLATION 2. SPECIFICATIONS OPERATION MANUAL 3. KEYBOARD LAYOUT AND DESCRIPTION 4. INITIAL SETUP PLEASE READ THIS MANUAL

More information

Sartorius Cubis Series

Sartorius Cubis Series Sartorius Cubis Series Laboratory balances MODULAR DESIGN General Specifications Power supply Input voltage 15 VDC, ± 5 % Power consumption Ambient temperature 100 240 V~, 15 %/+10 %, 50 60 Hz, 1.0 A 7W

More information

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy: π H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count counting scale 1-800-295-5510 uline.com 1-800-295-5510 GENERAL INFORMATION Avoid placing the scale in locations that may hurt accuracy: 1. Temperature

More information

System 3 ZB1PS Device Chassis. Operator s Manual

System 3 ZB1PS Device Chassis. Operator s Manual System 3 ZB1PS Device Chassis Operator s Manual System 3 ZB1PS Operator's Manual Copyright 2007 Tucker-Davis Technologies, Inc. (TDT). All rights reserved. No part of this manual may be reproduced or transmitted

More information

3. Operating instructions: Minor 200

3. Operating instructions: Minor 200 1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Operating Instructions. Magnetic Drive For EasyMax

Operating Instructions. Magnetic Drive For EasyMax Operating Instructions Magnetic Drive For EasyMax Table of Contents 1 Introduction 5 2 Safety 6 2.1 Definition of signal warnings and symbols 6 2.2 Product specific safety notes 6 3 Magnetic drive overview

More information

Model 1693, 1694 Switching DC Power Supply

Model 1693, 1694 Switching DC Power Supply Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Operating Instructions

Operating Instructions Tension Meter MST Series Edition MST 03.E Model MST Operating Instructions Valid as of: 01.02.2006 Please keep manual for future reference! Contents 1 Warranty and Liability... 3 1.1 Notices within Operating

More information

Manual Balanza dosificadora PCE-ABZ 200C

Manual Balanza dosificadora PCE-ABZ 200C www.pce-industrial-needs.com ursdale echnical Services Ltd Unit N12B ursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Operating Instructions (Translation)

Operating Instructions (Translation) Product Description Definition The ANTARES RCU consists of the ANTARES Head Module and the ANTARES Connection Module. The ANTARES Head Module contains a CPU, communication interface and power pack. In

More information

Date received into service; / /.

Date received into service; / /. Innovating Together RIGEL SafeTest 50 electrical safety analyzer Copyright 2016 SEAWARD GROUP Last Update: April 20th 2016 Instruction Manual 410A570 Revision 1.2 Limited Warranty & Limitation of Liability

More information

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

SolarMax S series (Australia) Maximising solar plant yields can be so easy. SolarMax S series (Australia) Maximising solar plant yields can be so easy. The convincing solution. We have been developing and producing transformerless inverters for over 20 years. Our engineers have

More information

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013) Adam Equipment DUNE DCT SERIES (P.N. 9384, Revision B2, June 2013) Adam Equipment Company 2013 Easy Reference: Model name of the scale: Serial number of the unit: Software revision number (Displayed when

More information

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x) Operating Instructions Installation Information METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x) www.mt.com/support Content 1. General information... 4 2. Safety instructions...

More information

CarePacs. Traceable Balance Testing for Secure Weighing Processes

CarePacs. Traceable Balance Testing for Secure Weighing Processes CarePacs CarePac Weight Sets Ensure valid weighing results Efficient and cost-effective Guaranteed traceability Traceable Balance Testing for Secure Weighing Processes CarePac Weight Sets Ensure Valid

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Turbocharger / VTR..0, VTR..1 Original assembly instructions English Assembly Instructions Turbocharger / VTR..0, VTR..1 Original assembly instructions English This document is valid for the VTR..0/..1 series: VTR160, VTR200, VTR250, VTR320, VTR400 VTR161, VTR201, VTR251,

More information

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit   for user manual translations USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www.extech.com for user manual translations Introduction Thank you for selecting the Extech Instruments 200A AC Mini Clamp Meter. The MA130

More information

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN 05-2018 ELECTRIC DEVICE UNDER VOLTAGE! Before any action related to the power supply (cables connection, device

More information

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive Vacuum Circuit-Breakers, Type HVX 12 24 kv, of cassette design, cassette with motor drive Operating Instructions No. 531 321, Edition 09/00 Table of Contents 1 General 4 1.1 Operating Conditions 4 2 Design,

More information

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS CONTENTS SAC SERIES TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE 1. INSTALLATION 2. SPECIFICATIONS 2.1 GENERAL SPECIFICATIONS 2.2 MINIMUM PIECES, WEIGHT APPLIED & SAMPLE SIZE WEIGHT SPECIFICATIONS OPERATION

More information

Operating Instructions Precision balance

Operating Instructions Precision balance KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com Tel: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Operating Instructions Precision balance KERN Version

More information

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of

More information

Weighing Scale IDS-802. User Manual

Weighing Scale IDS-802. User Manual Weighing Scale IDS-802 User Manual A. MAIN SPECIFICATION Model: Capacity: Accuracy: Display: IDS-802 Weighing scale 3kgx0.1g,6kgx0.2g,15kgx0.5g,30kgx1g Grade III, n=30,000 Single 6 digits LCD with Blue

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

Excellence Plus XP Precision balances from METTLER TOLEDO. Full Compliance High Productivity Amazing Solutions. That s the weigh! The Power of Color

Excellence Plus XP Precision balances from METTLER TOLEDO. Full Compliance High Productivity Amazing Solutions. That s the weigh! The Power of Color Excellence Plus XP Precision balances from METTLER TOLEDO Full Compliance High Productivity Amazing Solutions That s the weigh! The Power of Color Innovation addresses customer needs Your wishes? Our solution.

More information

Virtual Measurements & Control. VC210 Operators Manual

Virtual Measurements & Control. VC210 Operators Manual Virtual Measurements & Control VC210 Operators Manual Safety Notice 2 Technical Specification 3 Features 3 Theory of Operation 4 Operation 4 Enunciators 4 Buttons 5 Power Down Timer and Buzzer Setting

More information

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d)

CS-250 Series. CHAIR SCALE SERVICE MANUAL (v1.06d) CS-250 Series CHAIR SCALE SERVICE MANUAL (v1.06d) CONTENTS 1. PRECAUTIONS..2 2. INTRODUCTION 3 3. SPECIFICATIONS...4 3.1Specifications...4 3.2 Load Cell Specification......5 4. INSTALLATION..6 5. DESCRIPTION...8

More information

Operating Instructions CYR52

Operating Instructions CYR52 BA01300C/07/EN/02.14 71261315 Products Solutions Services Operating Instructions CYR52 Ultrasonic cleaning Document information Warnings The structure, signal words and safety colors of the signs comply

More information

Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help

Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help button in the top right corner. To view the presenter notes

More information

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Preface Overview 1 SIMATIC Industrial PC, Industrial monitor SIMATIC IPC277D/E 19" INOX PRO, SIMATIC IFP1900 INOX PRO Service Manual Safety instructions 2 Replacing the seal of the compartment cover 3

More information

CITIZEN. series. Precision Balances

CITIZEN. series. Precision Balances CITIZEN CZ series Precision Balances - 9 - CZ [NTEP ] User s Guide Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS. 2 SECTION 3 INSTALLATION....3 SECTION 4 KEY DESCRIPTIONS.. 4 SECTION 5 OPERATION.....5

More information

Megohmmeter Test Probe

Megohmmeter Test Probe Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced

More information

Arm - TX series 40 family

Arm - TX series 40 family Arm - TX series 40 family Characteristics Stäubli Faverges 2005 D18327304A - 02/2005 The specifications contained in the present document can be modified without notice. Although all necessary precautions

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents

More information

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING #61-085 #61-086 Read First: Safety Information This tester complies with UL3111-1, Cat III-600

More information

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions Emergency Power Supply for the OMEGA ACTIVE-System Operating Instructions Preface Preface These Operating Instructions will help you using the Emergency Power Supply as intended, safely, and advantageously.

More information

Analytical & Precision Balances

Analytical & Precision Balances Discovery Semi-Micro and Analytical The Professional s Choice for Analytical s up to 0.01 mg Rear mount load cell for ultimate accuracy Advanced AutoCal (2 internal calibration weights) 2 line backlit

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

CPS Energy Balancer. Version: 1.0

CPS Energy Balancer. Version: 1.0 CPS Energy Balancer Version: 1.0 CHINT POWER SYSTEMS AMERICA CO., LTD. Address: 700 International Parkway, Suite 102 Richardson, Texas Zip Code: 75081 Web: www.chintpower.com/na Email: americasales@chintpower.com

More information

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide

SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies. About the RMX Safety Information & Installation Guide SAFETY INFORMATION & INSTALLATION GUIDE RMX Programmable Power Supplies RMX-4120/4121/4122/4123/4124/4125/4126/4127 About the RMX Safety Information & Installation Guide This guide is intended for users

More information

Triple Output Power Supply

Triple Output Power Supply Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions

More information

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified OPERATIONS MANUAL Mini Centrifuge Model MCF-2360 Certified Contents 1. Safety 2 2. Introduction 7 3. Package Contents 7 4. Specifications 8 5. Features 8 6. Parts of the Mini Centrifuge 9 7. Installation

More information

SWISS MADE EXECUTIVE. Series 360 ES

SWISS MADE EXECUTIVE. Series 360 ES SWISS MADE EXECUTIVE Series Semi-micro Analytical Precision EXECUTIVE Precisa With the 360 series, Precisa is setting new standards in the demanding area of high-end laboratory balances: innovative, hightech

More information

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC

b3c OPERATING MANUAL (GB) 9260(A) (A) 9360 Compacts scales 9260 (A) Ver 2014 EN September BC b3c pesage 9260(A) 9360 Compacts scales 9260(A) 9360 OPERATING MANUAL (GB) 9260 (A) - 9360 Ver 2014 EN September BC 9260(A) - 9360 INSTRUCTION FOR USE AND MAINTENANCE Thank you for choosing the professional

More information

Turbocharger / TPS-H Original assembly instructions English

Turbocharger / TPS-H Original assembly instructions English Assembly Instructions Turbocharger / TPS-H Original assembly instructions English This document is valid for the TPS-H series: TPS44-H, TPS48-H, TPS52-H Purpose TPS-H turbocharger The assembly instructions

More information

MODEL PS-4 DIGITAL PORTION SCALE

MODEL PS-4 DIGITAL PORTION SCALE MODEL PS-4 DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG. CO. 8528-M317-O1 Rev A 203 E. Daugherty, Webb City, MO 64870 USA 07/05 Ph: 417-673-4631 Fax: 417-673-2153 www.detectoscale.com Technical

More information

Pressure Sensors. for liquid and gaseous media

Pressure Sensors. for liquid and gaseous media 1 909 1909P01 Pressure Sensors for liquid and gaseous media QBE2002-P QBE2102-P Piezo-resistive measuring system DC 0...10 V or DC 4 20 ma output signal Measurement unaffected by changes in temperature

More information

Standard Calibration Certificate

Standard Calibration Certificate Mettler Toledo Service Business Unit Laboratory 1900 Polaris Parkway Columbus, OH 43240 1-800-METTLER Customer Standard Calibration Certificate Company: ABC Pharma Incorporated Address: 1432 East 9th Street

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used.

Charder. Medical scale. User instruction. Important information. This user instruction must be read before the medical scale is used. Charder Medical scale User instruction Important information This user instruction must be read before the medical scale is used. This user instruction is intended for technicians, installers, therapists

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use. User Instruction Manual Oxford Classic Digital To avoid injury, read user manual prior to use. Oxford English Contents 1. Introduction: About Your Scale... 3 2. Assembly and Commissioning Instructions...

More information

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols Table of Contents Title Page Introduction Unpacking the Meter Safety Information International Electrical Symbols The Meter Structure Key Functions Rotary Switch Measurement Operation A. Measuring Voltages

More information

Precision Balances WEIGHING WITH EXPERIENCE

Precision Balances WEIGHING WITH EXPERIENCE Precision Balances WEIGHING WITH EXPERIENCE Analytical BL 224 Touch Touch screen Internal GLP RS-232 Density Touchscreen high definition display Automatic internal Electromagnetic sensor GLP protocol Multiple

More information

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to LM-100 LM-120 Light Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com LM-100 / LM-120 Light Meters English Users Manual LM100_Rev002 2008 Amprobe Test Tools.

More information

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales Operating instructions METTLER TOLEDO MultiRange Floor scales/pit scales KC300...x-T4 / KCS300...x-T4 KC600...x-T4 / KCS600...x-T4 KD600...x-T4 / KD1500...x-T4 KE1500...x-T4 / KE3000...x-T4 KES1500...x-T4

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

Lithium Power Supply

Lithium Power Supply Lithium Power Supply User Manual LPS 1200W-60Ah LPS 1500W-100Ah LPS 2500W-100Ah Compact lithium battery based power supply - for easy acces to 230V and 12V energy, everywhere! V1.1 Safety Instructions

More information

Operating manual. LabStation LS Flex/430

Operating manual. LabStation LS Flex/430 Operating manual LabStation LS Flex/430 ba75968edfs01 03/2012 Copyright Weilheim 2012, WTW GmbH Reproduction in whole - or even in part - is prohibited without the express written permission of WTW GmbH,

More information

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice. Digital Scale Revision 1.0 August 17, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702 Fax

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

Turbocharger / A100-L Original assembly instructions English

Turbocharger / A100-L Original assembly instructions English Assembly Instructions Turbocharger / A100-L Original assembly instructions English This document is valid for the A100-L series: A165-L, A170-L, A175-L, A180-L, A185-L, A190-L Purpose The assembly instructions

More information

photovoltaikforum.com

photovoltaikforum.com SolarMax 20C/25C/30C/35C Proven reliability. Proven reliability. Sputnik Engineering commissioned the first SolarMax PV central inverters in 1992. Since then thousands of central inverters have been put

More information

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08 USER S MANUAL G SERIES USER S MANUAL Ref.49-MG000EN08 Index USER S MANUAL 1. DESCRIPTION OF THE SERIE G SCALE... 1 1.1. KEYBOARD...1 2. INTRODUCTION... 2 2.1. GENERAL SPECIFICATIONS...2 2.2. OPERATIONAL

More information

Installation manual portable distributors

Installation manual portable distributors EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended

More information

Installation manual FS Cradle

Installation manual FS Cradle Installation manual FS Cradle Contact Priva B.V. Zijlweg 3 2678 LC P.O. Box 18 2678 ZG De Lier Nederland www.priva.nl contact.priva@priva.nl Article number 3791522 Version 1.2 Date 31-8-2017 Copyright

More information