OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS
|
|
- Buck Bishop
- 5 years ago
- Views:
Transcription
1 (Model Year 2014)
2 OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS MAGNETIC OIL LEVEL GAUGES (without contacts) Page Type IML 80 and IML 99. They are the two cheapest gauges of our range, with aluminium body, suggested to be used in distribution transformers (max conservator diameter 400mm). An arrow gives the indication of the oil level inside the conservator; they cannot be fitted with electric switches and they can be supplied only in the "R" execution (float movement parallel to the dial). SIDE WALL OIL LEVEL GAUGES Page 5.34 (drg B 3190). Prismatic type. They give an optic indication of the oil level inside a transformer tank or inside a conservator. The steel frame must be bolted to the wall of an hermetic transformer or to the end of a conservator of a conventional transformer. File : ACCESSORI DISTRIBUZIONE.doc UNCONTROLLED COPY REV 05 dtd 22/03/11
3
4
5 AIR DEHYDRATING BREATHERS for distribution transformers Type TV75-6 and VE05-VE10 1. GENERAL INFORMATION Air dehydrating breathers are transparent hollow cylinder tubes which contain chemically pure silicium salt (silicagel) with coloured indicator. The air breathed inside the transformer due to the thermal contraction of the oil mass, passes through the silicagel. The silicagel absorbs the humidity, indicating the saturation degree by changing colour as follows: ORANGE silicagel completely dry. WHITE silicagel saturated with humidity. The salt contained in the breather, when saturated, may be easily removed and regenerated by heating it, inside a ventilated oven, at C, until the colour becomes orange again. The specific property of the silicagel is its high absorption power of humidity. This is total until the salt has absorbed water for about 15% of its weight, and saturation is reached when the salt has absorbed water for 30 to 40 % of its weight. 2. TECHNICAL FEATURES The upper and lower parts are made in a non-porous corrosion-proof aluminium alloy casting. The hollow cylinder is made of plexiglass and it is protected by a stainless steel cylinder, with windows which allow the visual control of the silicagel colour. In the bottom side of the breather, an hydraulic valve prevents continuous air contact with the silicagel and allows the air to pass in both direction (inlet or outlet) only when there is pressure deficiency or excess inside the transformer. Pressure values for air passage into the dehumidifier are: kg/cm 2 inlet, or kg/cm 2 outlet. The hollow container and the hydraulic valve are separated by a drilled plate with a labyrinth system, which have the double purpose of diffusing inlet air uniformly, and of avoiding that any salt dust may damage the closing system. 3. AIR DEHYDRATING BREATHER TYPE TV75 & VE05 & VE10 (Drg.3535) They are small sized dehydrating breathers, particularly fit for assembling on small distribution transformers The type VE05 follows the same manufacturing principles of the bigger sizes like the type VE10. The type TV75 (or TV74) is the cheapest model of our breathers: its top flange is made in corrosion proof aluminium alloy. The silicagel housing is made of cellulose triacetate (cellidor by Bayer), suitable for mineral oil; only upon request, this breather can be fitted with a stainless steel cylindrical protection. File : ACCESSORI DISTRIBUZIONE.doc UNCONTROLLED COPY REV 05 dtd 22/03/11
6
7
8 THERMOMETERS For distribution transformers Page 5.15 : Thermometer MTVT 84 Oil temperature indicator, new concept, fitted with two independent microswirches, range C, only with bottom entry rigid bulb. Page 5.16 : Thermometers type BM (drg 1292) Bimetallic oil temperature indicator, without contacts, range C, with radial rigid stem or back entry, stainless steel housing. Page 5.17 & 5.19 : Thermometers type TESS Oil temperature indicators, standard quality, for small distribution transformers, with two low speed contacts (low rating), stainless steel housing, range C -(page drg 1290) with radial rigid stem, suitable for cover mounting -(page drg 1365) Thermometer type TESS-B-100 with back entry stem and with two contacts (for side wall mounting on transformers without conservator with nitrogen cushion) -(page drg 1365) Vacuum-Pressure Gauge VPG-100 with two contacts (for side wall mounting on transformers without conservator with nitrogen cushion) Page 5.19.A & 5.20.A: Thermometers type TECED High performance oil temperature indicators, organic liquid filled, for distribution transformers of bigger size or for small power transformers, with low speed contacts (low rating), aluminium housing, range C TECED-R with radial rigid stem (pag A) TECED-Y with armoured flexible capillary (pag A) HOUSING: Light aluminium alloy casting with glass window locked by a bronze ring PROTECTION DEGREE: IP 55 OUTDOOR MOUNTING: Allowed BREATHING DEVICE AND DRAIN SCREW: Supplied upon request, are necessary for the use of our thermometer in tropical climate zones, in order to avoid moisturing inside the casing STANDARD RANGE: C PRECISION CLASS: +/- 1,5 MAX POINTER: Supplied upon request CAPILLARY (only for form Y pag. 5.20A). Hermetically sealed capillary tube; bottom entry Armouring: Copper tube or zinckplated flexible sheath inside a plastic tube OIL IMMERSED BULB AND CONNECTOR: On pages 5.19.A and 5.20.A are shown the most commonly used styles, but it is possible to supply tailor made executions, according to customer's specifications. ELECTRIC CONTACTS: Two independent max contacts normally open (other wiring diagrams available upon request), air insulated, slow speed action (these contacts must always work through a relay, never directly on the circuit breaker) CONTACTS CHARACTERISTICS: Insulation test at 2000 V/ 50 Hz Rated voltage [V] Rated current [ma] dc ac / R load ac / ind. load SPECIAL CONTACTS: Contacts may be fitted with two small magnets, with the scope of avoiding sparks between them, due to the increased closing speed; consequently the current rating increases slightly, at a loss of precision of the temperature indication near to the contact set point, and the contact opening The t has a small increase. ORDERING INSTRUCTIONS: TECED type R or Y, nominal dial diameter, bulb style and connection, capillary entry - length - armouring ( only for form-y ), special requirements such as max pointer, breather, ground terminal, special wiring diagrams, special range or other. File : ACCESSORI DISTRIBUZIONE.doc UNCONTROLLED COPY REV 05 dtd 22/03/11
9
10
11
12
13
14
15
16
17
18
THERMOMETERS For distribution transformers
THERMOMETERS For distribution transformers Page 5.15 : Thermometer MTVT 84 Oil temperature indicator, new concept, fitted with two independent microswirches, range 0...120 C, only with bottom entry rigid
More informationLiquid filled Thermometers
Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description
More informationTERMINAL BOXES FOR OIL IMMERSED TRANSFORMERS (Series 2009)
TERMINAL BOXES FOR OIL IMMERSED TRANSFORMERS (Series 2009) File : Power TERM BOX ing UNCONTROLLED COPY rev01 dtd 17/07/08 GENERAL FEATURES The measurement, control, check and data recording circuits for
More informationOil level gauges Series IL
Oil level gauges Series IL Cat: 11ILCATR04-E Rev: 04 08/2009 Catalogue N 11ILCATR01-E Rev. N 01 13.10.2002 11 Oil Level Gauges Series IL Page N 1 of 3 1 General Information It is necessary to measure the
More informationFlow Meter Terminal Boxes
Shutter Flow Meter Terminal Boxes Shutter Flow meter Terminal boxes 02 07 11 1 Shutter Valve DAROC Description and general specifications Production range and operating conditions Operation Installation,
More informationTHERMOMETERS FOR TRANSFORMERS
THERMOMETERS FOR TRANSFORMERS GENERAL DESCRIPTION This instrument measures the insulating oil in the transformer. They are studied for withstanding to the most adverse process conditions due to the aggressiveness
More informationGas-actuated thermometer Model 73, stainless steel version
www.materm.si tel: 02 608 90 10 Mechanical temperature measurement Gas-actuated thermometer Model 73, stainless steel version WIKA data sheet TM 73.01 Applications For aggressive media in the chemical,
More informationTHROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009
THROTTLE VALVES FOR RELAYS AND RADIATORS Series 2009 1General Features 1.1Characteristics The butterfly valves, metal to metal sealing withy thin blade(or full tightening type, with o-ring blade), are
More informationTHERMOMETERS FOR POWER TRANSFORMERS Oil temperature indicators O.T.I. Winding temperature indicators (thermal image) - W.T.I.
THERMOMETERS FOR POWER TRANSFORMERS Oil temperature indicators O.T.I. Winding temperature indicators (thermal image) - W.T.I. In power transformers it is necessary to have the control of the oil temperature
More informationBUSHINGS: GENERAL INFORMATION
BUSHINGS: GENERAL INFORMATION 1.0 Electrical characteristics (Ir = rated current; Ur = rated voltage) 1.1Standard insulation levels Rated voltage Ur kv (r.m.s.) 1 3,6 12 24 36 52 One minute power frequency
More informationSAMPLE PRODUCT SPECIFICATIONS
SAMPLE PRODUCT SPECIFICATIONS Thermometers & Gauges Product Guide Specification THERMOMETERS & GAUGES Specifier Notes: This section covers Miljoco Corporation thermometers and pressure gauges suitable
More informationGas-actuated thermometer with switch contacts Model 73, stainless steel version
Mechatronic temperature measurement Gas-actuated thermometer with switch contacts Model 73, stainless steel version WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation
More informationGas Actuated Thermometers Stainless Steel Series, Model 73
Mechanical Temperature Measurement Gas Actuated Thermometers Stainless Steel Series, Model 73 WIKA Data Sheet TM 73.01 Applications For aggressive media in the chemical, petrochemical and process engineering
More informationDial thermometers. Gas filled system and Bi-metal. dial thermometers
JJ Dial thermometers JJ Diesel engine thermometers JJ Low temperature dial thermometers JJ Remote reading dial thermometers JJ Remote reading diesel engine thermometers JJ Remote reading low temperature
More informationBuchholz Relays Series RR - RRF - GQ
Buchholz Relays Series RR - RRF - GQ Catalogue N : 04RRCATR03-E Revision: 03 of 29.06.2004 04RRGENR05-E Buchholz Relays "Custos" Series RR, RRF, GQ 1 of 4 Function and construction, functional and operating
More informationEJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...
EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)
More informationGas-actuated thermometer with switch contacts Stainless steel version Model 73
Temperature Gas-actuated thermometer with switch contacts Stainless steel version Model 73 WIKA data sheet TV 27.01 for further approvals see page 12 Applications Control and regulation of industrial processes
More informationIndustrial-Thermometer
Industrial-Thermometer Index According to Types Industrial Thermometers Details of Design Casings Aluminum, V-shaped, completely polished, gold-colored anodized (or silvercolored upon request). Numerals
More informationRemote reading dial thermometers, version for industry
Remote reading dial thermometers, version for industry Type 313 WH, 323 TA, 333 TE and 334 KL Measuring system Nitrogen filled Type 313 WH Accuracy (EN 13190) Class 1 Case Crimped-on ring, stainless steel
More informationTWM 7284 & TWM Microswitches equipped Thermostats type :
Microswitches equipped Thermostats type : TWM 7284 & TWM 7287 Introduction Description and general specifications Options Operating instructions and maintenance Finished product quality control tests 02
More informationDesign specifications
Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor
More informationPORCELAIN BUSHINGS ED Series
PORCELAIN BUSHINGS ED Series An innovative design: the most popular and most reliable 1 kv bushing on the market www.cedaspe.com LV BUSHINGS ED by CEDASPE CEDASPE is happy to present a complete new family
More informationLinear Valve Electric Actuator
Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest
More informationGAS ACTUATED RELAYS FOR OIL FILLED TRANSFORMERS EN
GAS ACTUATED RELAYS FOR OIL FILLED TRANSFORMERS EN 50216-2 Nome file : RELE EN50216 REV 04 DTD 23/04/2007 Pagina 1 di 22 1. General Features 1.1 Characteristics The gas-actuated protective relay is designed
More informationDistribution transformers Efficiency over life-cycle
Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while
More informationMSRT 150. Oil Temperature Indicator for Power Transformer type :
Oil Temperature Indicator for Power Transformer type : MSRT 150 Introduction Description and general specifications Options Operating instructions and maintenance Finished product quality control tests
More informationTRANSPORT. Take all the necessary precautions to prevent the load from knocking against the vehicle during transport. - 1/5 -
TRANSPORT The unit is arranged lengthwise in the vehicle. The rollers must be removed and can be fastened the wrong way around on the substructures or packed in a cardboard box inside the box. The unit
More informationMESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements
Dehydrating Breather Technical data Product variants This technical document contains detailed information about the technical properties of the product. If you would like to place an order, please use
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 230519 - METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 ABBREVIATIONS A. Degree
More informationHistory of the company. TUMETIC and TUNORMA: Tailor-Made Technology
History of the company Csepel Transformer Factory was founded in 1960 as a state owned company in the location of the large industrial estate in southern Budapest situated on the island of the Danube river.
More informationMODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)
1. Description: PC 252 is a Liquid-in-Metal expansion type Self powered Oil/ Winding Temperature Indicator for Power & Distribution transformers. PC 252 is Approved & Used by all reputed customers in India
More informationKey features. DESIGNS: - Conservator type - Hermetically sealed
Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the
More informationTransformer Components & Accessories
Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers
More information* T Temperature-Indicating Dial (Must be field set and calibrated to an actual thermometer)
175/153 Series Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2006 Watson McDaniel Company 175 HEATING 153 COOLING 175 / 153 Screwed Connection
More informationVALVE WITH SA ELECTRIC ACTUATOR
752-753 VALVE WITH SA ELECTRIC ACTUATOR CHARACTERISTICS The 752-753+SA ball valve is dedicated to the automatic opening/shut-off of pipes carrying unloaded industrial fluids with a 16 bar maximum pressure.
More informationSECTION METERS AND GAGES FOR PLUMBING PIPING
PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.
More informationBUCHHOLZ RELAYS EE Series
BUCHHOLZ RELAYS EE Series The newest Buchholz relay release for use in oil-immersed power transformers www.cedaspe.com 1. General Features 1.1 Characteristics The gas-actuated protective relay is designed
More informationBuchholz Relay MBP Gas and Oil Actuated Relay
Buchholz Relay MBP Gas and Oil Actuated Relay Reed switches for detection of gas formation and dropping oil level Flap valve to protect in case of excessive high oil flow rate Separated oil and switching
More informationTECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105
TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to
More informationRELAYS. Figure Relay construction.
RELAYS The RELAY is a device that acts upon the same fundamental principle as the solenoid. The difference between a relay and a solenoid is that a relay does not have a movable core (plunger) while the
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationFIRE CONTROL
48 FIRE CONTROL FIRE HOLD OPEN MAGNETS HYDRAULIC DAMPERS FOR SLIDING DOORS HYDRAULIC IMPACT SHOCK ABSORBERS SINGLE ZONE FI RE CONTROLLER FIRE AND SMOKE DETECTORS 49 50 FIRE CONTROL www.opera-italy.com
More informationA6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10
A6C A5C-B6C B5C B5H Model Power Voltages Model IP55 A6C A5C B6C B5C B5H Up to 2.400 kw Up to 11.000 V LV A6C - B6C - A5C - B5C MV B5H Frame 71 560 Pole 2, 4, 6, 8 and 10 Cooling IC 411 ( IC 416 optional)
More informationENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head
ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with Compact KNS Head Pt100 probe with compact KNS terminal head Class B, 4 wire connection Various probe available lengths
More informationNARVIK-YARWAY. High Pressure Level Gauges, Model: 17
NARVIK-YARWAY Narvik-Yarway covers requirements for level gauges and electronic water level systems with a wide range of models, sizes and materials to satisfy all the specifications of the power and process
More informationTemperature Regulators
Temperature Regulators DESIGN & OPERATION DIAL THERMOMETER (Model 91400 only) BELLOWS OVERRANGE PROTECTION SPRING CAPILLARY TUBING CONNECTION SENSING BULB RANGE ADJUSTMENT SPRING CAP ADJUSTMENT SCREW BUSHING
More informationFoxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element
Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement
More informationMESSKO MTO Oil Level Indicator
MESSKO MTO Oil Level Indicator Technical data Product variants 1 2 1 4 5 6 7 3 This technical document contains detailed information about the technical properties of the product. If you would like to
More informationScrew jacks MA Series
Screw jacks MA Series Screw jacks MA Series with travelling screw (Mod.A) STRUCTURAL ELEMENTS 1 10 11 8 7 6 1 3 13 4 9 14 8 11 10 5 6 7 1 - acme screw in steel C 43 (UNI 7847), whirled thread - worm shaft
More informationCAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00
CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00 1 HISTORY INESING SRL is a dynamic and modern company, very well known in the design and production of dry type (cast resin ) transformer up to 36kV -10MVA,
More informationGauges, Sight Glasses and Vacuum Breakers
Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure
More information1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.
1. SPECIFICATION 5 GENERAL INFORMATION Motors with parameters according to the data sheet comply with the requirements of the IEC 60034-1 standard, and IEC 60034-30 class efficiency IE2 Motor versions:
More informationTemperature Switch Gauges
Temperature Switch Gauges I MODEL DESCRIPTION MOUNTING TSG60B Bracket Mount (Standard) Surface TSG60K Back Flange Surface TSG60S Front Flange Panel TSG60X Explosion Proof (3 Switch Max.) Surface WINDOW
More informationProduct features & Overview. KA Linear actuators
Product features & Overview Linear actuators 66 Linear actuators Linear actuator Product features Wide range of force outputs Solid metal housing Large stroke range Maintenance-free gearbox Wide range
More informationDiesel engine dial thermometers
Diesel engine dial thermometers Local reading dial thermometers This range of instruments includes special precision dial thermometers optimised for marine engines, based on the nitrogen gas expansion
More informationPNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper
GE Grid Solutions PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper PNO bushings are capacitance graded bushings with an oil impregnated paper core. PNO bushings are conform
More informationIndustrial Substation Maintenance April $4,250 Abu Dhabi. UAE
Training Title INDUSTRIAL SUBSTATION MAINTENANCE Training Duration 5 days Training Venue and Dates Industrial Substation Maintenance 5 19 23 April $4,250 Abu Dhabi. UAE Training will be held at any 5 Star
More informationELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables
ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable 0.6 / 1kV XLPE Insulated Unarmoured Cables 0.6 / 1kV XLPE Insulated Armoured Cables 1.8 / 3kV XLPE Insulated Armoured Cables 3.6 / 6kV
More informationKombiTemp. Head form B / Head form J Cable socket, angle type Diesel engine dial thermometers. Temperature Sensors with local display
JJ Head form B / Head form J JJ Cable socket, angle type JJ Diesel engine dial thermometers KombiTemp Temperature Sensors with local display Including products with: DS_KombiTemp 8/5 Dual temperature control
More informationTRANSFORMERS UP TO 750 kv
Electric Co. Ltd. TRANSFORMERS UP TO 750 kv CONTENTS General... 2 Products... 3 Construction...4 Magnetic core... 4 Windings...5 Frame structure... 6 Connections...6 Tap changer and motor drive...7 Tank...
More informationMTF-E. Technical features
Technical features Power supply Threephase voltage from 220V to 690V, 50Hz or 60Hz; suitable for use with a PM inverter from 20Hz to the base frequency with constant torque load profile. Polarity 2 and
More informationWe proudly deliver a unique and
Linear 3-Way Control Valve PN 10/16/25, DN15 - DN300 BENEFITS Nominal pressure PN 16 Almost linear Two balance single seats kvs Regulating capability > 25 kvr Leakage 0.05% of kvs For regulating of process
More informationMODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC
MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................
More informationCAST RESIN TRANSFORMERS
MODEL TAM CAST RESIN - TAM TYPE Epoxy cast resin dry-type transformers are recommended to operate in places that require security, the materials used in its construction are hard to combust and are self-extinguishable
More informationVALVES WITH SA ELECTRIC ACTUATOR
505-507 VALVES WITH SA ELECTRIC ACTUATOR CHARACTERISTICS The 505+SA and 507+SA cast iron ball valves are dedicated to the automatic opening/shut-off of pipes carrying low pressure unloaded common fluids.
More informationXS-F VALVE WITH SA ELECTRIC ACTUATOR
702-703XS-F VALVE WITH SA ELECTRIC ACTUATOR CHARACTERISTICS The 702-703 XS-F + SA valve is a ball valve dedicated to the automatic opening/shut off of industrial uncharged fluids below 137 bar and 220
More informationSeries Cylinders according to standard ISO 15552
Series 131-11 General This series of pneumatic cylinders is manufactured according to ISO 31 standards adapted to MA 2 and CNOMO/AFNOR 3 that guarantee the interchangeability of the cylinders even without
More informationMTF. Technical features
Technical features Power supply Three-phase voltage from 24V to 690V, 50Hz or 60Hz or 100-130V, 60Hz and 200-240V, 50Hz ( types are supplied without capacitor); suitable for use with an inverter from 20Hz
More informationPressure Controller. Cataloge K Code Characteristics Index. K00-2 Pressure Controller Brief Introduction
K Pressure Controller Cataloge Code Characteristics Index K00-2 Pressure Controller Brief Introduction KC32 Screw Tube Differential Pressure Controller K01 KY10 Bellows Type Differential Pressure Controller
More informationBUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS
BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS COMPANY PROFILE Founded by the Giorgi family in 1967, CEDASPE has been manufacturing bushings and accessories for distribution and power
More informationELECTRIC SUBMERSIBLE PUMPS SEMISOM/80
Electric pumps for professional applications to convey sewage water, entirely designed and manufactured in our Italian facility. APPLICATION PERFORMANCE RANGE To convey waste and sewage water from septic
More informationOIL TO AIR BUSHINGS SERIES PNO. VOLTAGE FROM 52 kv TO 245 kv
Nuova Strada di Piano PPR 20099 Sesto San Giovanni (MI), Italy Tel. +39 02 24 10 50 01 www.alstom.com Page 1 of 17 OIL TO AIR BUSHINGS SERIES PNO VOLTAGE FROM 52 kv TO 245 kv INSTRUCTION FOR STORAGE, TRANSPORTATION,
More informationW91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer
Design & Operation W91 Non-Indicating W94 Dial Thermometer Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2010 Watson McDaniel Company CAPILLARY
More informationPARAMAX Series. Agitator Drives CW11
PARAMAX Agitator Drives 9000 Series CW No. G60E-.0 No. G60E- Agitator Drives Features.Easy to mount Flange mounting Compact gearbox allows simpler mounting base. Oil pump requires no electricity..compact
More informationKOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04
KOBOLD VKA FLOWMETER/SWITCH User Instructions Manual-VKA_03-04 VKA Table of Contents 1.0 General............................................. 1 Specifications..........................................
More informationVALVES WITH NA ELECTRIC ACTUATOR
505-507 VALVES WITH NA ELECTRIC ACTUATOR CHARACTERISTICS The 505+NA and 507+NA cast iron ball valves are dedicated to the automatic opening/shut-off of pipes carrying low pressure unloaded common fluids.
More informationDG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators
Clogging Indicators DG 03 DG 04 DG 05 DG 041 DG 04 For Pressure and High Pressure Filters Operating pressure up to 657 psi Response/Switching pressure up to 73 psi 60.30-4us Description Application Monitoring
More informationResistance thermometer with digital indicator Model TR75, battery operation
Electrical temperature measurement Resistance thermometer with digital indicator Model TR75, battery operation WIKA data sheet TE 60.75 Applications DiwiTherm Machine building, plant and vessel construction
More informationSize and Configurations
!!"#!""!"$%!!" &'()&('& AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent
More informationGT All SS Industrial Dial Thermometer Gas Filled system
TM ll SS Industrial Dial Thermometer Gas Filled system Special Features approved electrical contacts. Inert gas filled expansion system. Stainless steel case & stem With or without thermowell Silicon oil
More informationÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a
ÒÌÃ TRNSFORMERS ÒÌÃ three-phase oil transformers are intended for transforming of electric energy in networks of power systems and in energy consumer networks. Transformers are designed for indoor or outdoor
More informationThermal Overcurrent Circuit Breaker 3120-F...
Thermal Overcurrent Circuit Breaker 0-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of
More informationINDEX. The technical and dimensional data reported in this manual may be modified in view of any product improvement.
Ceiling-mounted fan heaters TECHNICAL MANUAL GB INDEX 1 MAIN FEATURES... 2 2 RATED TECHNICAL DATA... 3 3 HEATING CAPACITIES... 4 3.1 Heating capacity with water operation... - 11 4 STEAM OPERATION... 12
More informationGas-actuated thermometer Highly vibration resistant Model 75, stainless steel version
Mechanical temperature measurement Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version WIKA data sheet TM 75.01 for further approvals see page 5 Applications For the local
More informationSeries TNS/TNF Thermometers Installation/Operation Instructions
Precautions Please read the entire manual prior installing this product. These instructions include information on the TNS/TNF series capillary and rigid stem thermometers. Refer to the part number label
More informationSAV Electronic Valve Actuator
Document No. 155-548 Non-spring Return, 24 Vac/dc, 3-Position Control Description The SAV Non-spring Return (NSR), Electronic Valve Actuator requires a 24 Vac/dc supply to provide three-position (floating)
More informationV230T. Mould Hydraulic Systems. Hydraulic cylinders - high temperature 230 bar V230T
V230T Mould Hydraulic Systems Hydraulic cylinders - high temperature 230 bar V230T V230Tcat.GB01-2006 Hydraulic cylinders-with tie rods 1 2 3 4 5 6 7 8 9 Chrome-plated steel rod, hardened or tempered and
More informationWe uses No Cobalt (Neo-Blue) of pro-environment as dehydrator to be filled in the container of all breathers.
Product Group : T01 The dehydrating breather is connected to conservator or Gas Oil Sealing Tank as one of oil conservation systems through long pipe. The dehydrating breather is an apparatus to reduce
More informationUNIBAD. Bath water circulating pump
UNIBAD Bath water circulating pump Copyright erborner umpenfabrik J.. offmann Gmb & Co. KG Design rights reserved UNIBAD benefits that ensure operational safety and cost-effectiveness in continuous operation.
More informationWINTERS ( )
Economy Economy Test Panel Mounted Economy Spiral Tube Series New Sizes! Economy CRN Description The Winters Economy Gauge is designed for applications where cost savings are paramount. Many configurations
More informationClass 1 as per EN o C to 65o C 15 kg/cm2 ( without thermowell ) 120 % of Full Scale 8 mm ½ BSP (M) Adjustable
Special Features & tex approved electrical contacts. Inert gas filled expansion system. Stainless steel case & stem With or without thermowell Silicon oil filled (optional) Standard followed EN 90. pplication
More informationINSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03
INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment
More informationProtection against mechanical impacts IK 08 according to IEC 68, EN Insulation class Class F (155 C), class H (180 C) on request.
MVSI The MVSI series represents the line of reference products for manufacturer s of vibrating machines and plants operating in many industrial sectors and is made up of the largest range on the market,
More informationCompact temperature switch Model TCS
Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications
More informationProduct presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology
Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does
More informationBushing Insulators according to DIN and UNEL Standards
Bushing Insulators according to DIN and UNEL Standards Description and general specifications Outdoor transformer bushing DIN 42532 and UNEL 38159/74 rated current 630A Bushing EN 50180 12-24-36/630-1250-2000-3150
More informationMotors Automation Energy Transmission & Distribution Coatings. Flat-frame Motors K1F / K2F
Motors Automation Energy Transmission & Distribution Coatings Flat-frame Motors K1F / K2F WEG Group WEG is a leading global solutions provider for drive technology, energy generation and distribution,
More informationBimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version
Mechatronic temperature measurement Bimetal thermometer with Pt100 electrical output signal Model 54, stainless steel version WIKA data sheet TV 15.01 Applications Twin-Temp Machine building, plant and
More informationCX1 ProVector Explosion-Proof Heaters
Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy
More informationHow to Select the RE Industrial Actuator Part Number
How to Select the RE Industrial Actuator Part Number RE 10 T F 2 Torque (in-lb) 1.5 150 3 300 6 600 8.5 850 10 1000 15 1500 20 2000 25 2500 30 3000 Reversing Electronic Torque Maximizer (optional) Increases
More information