2 History of the company Csepel Transformer Factory was founded in 1960 as a state owned company in the location of the large industrial estate in southern Budapest situated on the island of the Danube river. The core business of the factory was to produce oil immersed MV/LV distribution transformers, in the early years for the domestic elctricity networks, and very soon for an ever increasing number of export markets. The production of a relatively new brand of transformers, the cast-resin insulated transformers was started in 1978 based on a licence acquired from the German producer, Trafo Union. In the course of the privatisation process Siemens AG acquired the shares of Csepel Transformer Factory in 1996 and it became an important branch of Siemens AG s transformer business. 2 TUNAMIC and TUNORMA Oil/Filled Distribution Transformers Following the takeover process the Company was able to obtain its first Quality Certification according to ISO 9001 within a year, in The development of new business fields e.g. coil winding for Traction Transformers together with Siemens Nürnberg was completed in The name of the company was changed to "Siemens Transformers Kft.. in The same year witnessed an important event, that is the takeover of production and responsibility of the cast resin transformers with the brand name Geafol transformers >400 kva from the German production center. In 2001 other important event happened : the production and responsibility of oil transformers < 250 kva was taken over from Portugese production center. Since then the Company has grown steadily in production capabilities, shortened its lead times and supplies distribution transformers, oil immersed and cast-resin alike, to an ever expanding number of export markets all over the Globe. TUMETIC and TUNORMA: Tailor-Made Technology TUMETIC Hermetically sealed distribution transformers completely filled with oil as cooling and insulating medium, for power ratings from 250 to 1600 kva and operating voltages up to a maximum of Um = 36 kv Cable elbow connectors on the HV side, open bushings on the LV side. TUNORMA Oil-filled distribution transformers with conservator for power ratings from 50 to 2500 kva and operating voltages up to a maximum of Um = 36 kv. Standard: DIN Rated power: kva Rated frequency: 50 Hz HV rating: up to 36 kv Taps on HV side: +-2.5% or +- 2 x 2.5% LV rating: V (special designs for up to 12 kv can be built) Connection: HV winding: delta, LV winding: star (up to 100 kva: zigzag) Impedance voltage 4% (only up to HV rating 24 kv and < 630 kva) or 6% at rated current: (with rated power > 630 kva or with HV rating > 24 kv) Cooling: ONAN Protection class: IP00 Final coating: RAL 7033 (other colours are available) Terminal compartment with cable connections on both HV and LV side. Terminal compartment with flange frame on both HV and LV side.

3 Oil/Filled Distribution Transformers TUNAMIC and TUNORMA 3 Main components and internal structure View inside a 630 kva TUMETIC oil-filled distribution transformer Truck with flat-rim wheels which can be set for forward or sideways movement. Core- and coll-assembly featuring iron core and windings held together by a clamping frame and bolted to the tank cover. It can be lifted whole from the tank. Iron core High-grade electric sheet steel (together with state-ofthe-art core design and laminations) assures low-loss, low-noise operation. Windings The design and materials selected assure a long service life. Off-load tap changer for matching the voltage to local network conditions. Adjustablefrom the outside in off-circuit state. Low-voltage bushings (standard) High-voltage bushings (standard) Thermometer pocket for temperature monitoring devices. Tank of the TUMETICmodel, hermetically sealed. The fluctuations in the cooling liquid volume occuring during operation are absorbed by the elasticity of the corrugated walls. Absolutely maintenance-free (no shortening of the service life) Conservator (on TUNORMA model) with oil-level indicator and filler nozzles in the form of air vents. Anti-corrosion: Multilayer paint finish, standard colour cement-grey (RAL 7033).Special colours or zinc coating available on request.

4 4 TUNAMIC and TUNORMA Oil/Filled Distribution Transformers Protection and monitoring devices Features and operating causes TUMETIC and TUNORMA Dimensions and accessories (see also technical Date Sheets) Dial type thermomether : For kva on request. Temperature of transformer oil. D.G.P.T. 2 Relay Complex protection device for Discharge of gases Oil pressure Oil temperature ( 2 contacts) Hermetic Protection: Vertical oil level switch R1 Gas Relay: Gas actuated relay with two contacts Double float Buchholz relay: In TUNORMA types floats (2 systems), baffle plate with contacts.for 400 and 630 kva on request. On 1000 and 1600 kva standard accessory Gas formation, oil loss, oil flow. Dehydrating breather in TUNORAMA types (on request): Desiccant filling 0,5 kg/1 kg Magnetic oil level indicator: In TUNORAMA types, float movement is transmitted to pointer via magnets. Oil level indicator. Safety valve in TUMETIC types: In case of overpressure higher than the set value it releases the excess pressure. Further accessories on request: Noise absorbing pad (4 pcs) Flexible connecting elements. 11 H N 2U 2V 2W 1U 2U 1W B1 2 Oil drain plug 3 Thermometer pocket 6 Adjustment for off-load tap changer 7 Rating plate (relocatable) 8 Grounding terminals 7 2 E 8 E 9 6 A1 9 Towing eye, 30 mm dia. 10 Lashing lug 11 Filler pipe 12 Mounting facility for protective device Fig. 24: TUMETIC distribution transformer (sealed tank) 4 H N 2U 2V 2W 1U 2U 1W B1 1 Oil level indicator 2 Oil drain plug 3 Thermometer pocket 4 Buchholz relay (optional extra) 5 Dehydrating breather (optional extra) 2 E 8 7 E 9 6 A1 6 Adjustment for off-load tap changer 7 Rating plate (relocatable) 8 Grounding terminals 9 Towing eye,30mm dia. 10 Lashing lug Notes: Tank with strong corrugated walls shown in illustration is the preferred design. With HV ratings up to 24 kv and rated power upto 250 kva (and with HV ratings > kv and rated power up to 800 kva), the conservator is fitted on the long side just above the LV bushings. Fig. 25: TUNORAMA distribution transformer (with conservator)

5 TUMETIC and TUNORMA Technical Data Technical Data Rated Power Sn(kVA) Rated Primary Voltage Um (kv) Voltage Impedance % Type Designation TUNORMA Type Designation TUMETIC Loss Combination No-load Loss Po(W) Load Loss Pk(W) Sound Pressure Level 1m LpA (db) Sound Power Level LwA (db) Total Weight kg Oil Weight kg Length A1 mm JB4736-3AA 4HB4736-3AA A-A' JB4744-3AA 4HB4744-3AA A-A' JB4767-3AA 4HB4767-3AA A-A' JB5036-3AA 4HB5036-3AA A-A' JB5044-3AA 4HB5044-3AA A-A' JB5067-3AA 4HB5067-3AA A-A' JB5236-3AA 4HB5236-3AA A-A' JB5244-3AA 4HB5244-3AA A-A' JB5267-3AA 4HB5267-3AA A-A' JB5436-3AA 4HB5436-3AA A-A' JB5444-3AA 4HB5444-3AA A-A' JB5467-3AA 4HB5467-3AA A-A' JB5636-3AA 4HB5636-3AA A-A' JB5644-3AA 4HB5644-3AA A-A' JB5667-3AA 4HB5667-3AA A-A' JB5836-3AA 4HB5836-3AA A-A' JB5844-3AA 4HB5844-3AA A-A' JB5867-3AA 4HB5867-3AA A-A' JB5836-3BA 4HB5836-3BA A-A' JB5844-3BA 4HB5844-3BA A-A' JB5867-3BA 4HB5867-3BA A-A' JB5936-3BA 4HB5936-3BA A-A' JB5944-3BA 4HB5944-3BA A-A' JB5967-3BA 4HB5967-3BA A-A' JB6036-3BA 4HB6036-3BA A-A' JB6044-3BA 4HB6044-3BA A-A' JB6067-3BA 4HB6067-3BA A-A' JB6136-3BA 4HB6136-3BA A-A' JB6144-3BA 4HB6144-3BA A-A' JB6167-3BA 4HB6167-3BA A-A' JB6236-3BA 4HB6236-3BA A-A' JB6244-3BA 4HB6244-3BA A-A' JB6267-3BA 4HB6267-3BA A-A' JB6336-3BA 4HB6336-3BA A-A' JB6344-3BA 4HB6344-3BA A-A' JB6367-3BA 4HB6367-3BA A-A' JB6436-3BA 4HB6436-3BA A-A' JB6444-3BA 4HB6444-3BA A-A' JB6467-3BA 4HB6467-3BA A-A' JB4736-3RA 4HB4736-3RA A-C' JB4744-3RA 4HB4744-3RA A-C' JB4767-3RA 4HB4767-3RA A-C' JB5036-3RA 4HB5036-3RA A-C' JB5044-3RA 4HB5044-3RA A-C' JB5067-3RA 4HB5067-3RA A-C' JB5236-3RA 4HB5236-3RA A-C' JB5244-3RA 4HB5244-3RA A-C' JB5267-3RA 4HB5267-3RA A-C' JB5436-3RA 4HB5436-3RA A-C' JB5444-3RA 4HB5444-3RA A-C' JB5467-3RA 4HB5467-3RA A-C' JB5636-3RA 4HB5636-3RA A-C' JB5644-3RA 4HB5644-3RA A-C' JB5667-3RA 4HB5667-3RA A-C' JB5836-3RA 4HB5836-3RA A-C' JB5844-3RA 4HB5844-3RA A-C' JB5867-3RA 4HB5867-3RA A-C' JB5836-3SA 4HB5836-3SA A-C' JB5844-3SA 4HB5844-3SA A-C' JB5867-3SA 4HB5867-3SA A-C' JB5936-3SA 4HB5936-3SA A-C' JB5944-3SA 4HB5944-3SA A-C' JB5967-3SA 4HB5967-3SA A-C' JB6036-3SA 4HB6036-3SA A-C' JB6044-3SA 4HB6044-3SA A-C' JB6067-3SA 4HB6067-3SA A-C' JB6136-3SA 4HB6136-3SA A-C' JB6144-3SA 4HB6144-3SA A-C' JB6167-3SA 4HB6167-3SA A-C' JB6236-3SA 4HB6236-3SA A-C' JB6244-3SA 4HB6244-3SA A-C' JB6267-3SA 4HB6267-3SA A-C' JB6336-3SA 4HB6336-3SA A-C' JB6344-3SA 4HB6344-3SA A-C' JB6367-3SA 4HB6367-3SA A-C' JB6436-3SA 4HB6436-3SA A-C' JB6444-3SA 4HB6444-3SA A-C' JB6467-3SA 4HB6467-3SA A-C' JB4736-3LA 4HB4736-3LA B-A' JB4744-3LA 4HB4744-3LA B-A' JB4767-3LA 4HB4767-3LA B-A' JB5036-3LA 4HB5036-3LA B-A' JB5044-3LA 4HB5044-3LA B-A' JB5067-3LA 4HB5067-3LA B-A' JB5236-3LA 4HB5236-3LA B-A' JB5244-3LA 4HB5244-3LA B-A' JB5267-3LA 4HB5267-3LA B-A' JB5436-3LA 4HB5436-3LA B-A' JB5444-3LA 4HB5444-3LA B-A' JB5467-3LA 4HB5467-3LA B-A' JB5636-3LA 4HB5636-3LA B-A' JB5644-3LA 4HB5644-3LA B-A' JB5667-3LA 4HB5667-3LA B-A' JB5836-3LA 4HB5836-3LA B-A' JB5844-3LA 4HB5844-3LA B-A' JB5867-3LA 4HB5867-3LA B-A' JB5836-3PA 4HB5836-3PA B-A' JB5844-3PA 4HB5844-3PA B-A' JB5867-3PA 4HB5867-3PA B-A' JB5936-3PA 4HB5936-3PA B-A' JB5944-3PA 4HB5944-3PA B-A' JB5967-3PA 4HB5967-3PA B-A' JB6036-3PA 4HB6036-3PA B-A' JB6044-3PA 4HB6044-3PA B-A' JB6067-3PA 4HB6067-3PA B-A' JB6136-3PA 4HB6136-3PA B-A' JB6144-3PA 4HB6144-3PA B-A' JB6167-3PA 4HB6167-3PA B-A' JB6236-3PA 4HB6236-3PA B-A' JB6244-3PA 4HB6244-3PA B-A' JB6267-3PA 4HB6267-3PA B-A' JB6336-3PA 4HB6336-3PA B-A' JB6344-3PA 4HB6344-3PA B-A' JB6367-3PA 4HB6367-3PA B-A' Width B1 mm Height H1 mm Distance between wheels E mm Rated Power Sn(kVA) Rated Primary Voltage Um (kv) Voltage Impedance % Type Designation TUNORMA Type Designation TUMETIC Loss Combination No-load Loss Po(W) Load Loss Pk(W) Sound Pressure Level 1m LpA (db) Sound Power Level LwA (db) Total Weight kg Oil Weight kg Length A1 mm JB4736-3MA 4HB4736-3MA B-C' JB4744-3MA 4HB4744-3MA B-C' JB4767-3MA 4HB4767-3MA B-C' JB5036-3MA 4HB5036-3MA B-C' JB5044-3MA 4HB5044-3MA B-C' JB5067-3MA 4HB5067-3MA B-C' JB5236-3MA 4HB5236-3MA B-C' JB5244-3MA 4HB5244-3MA B-C' JB5267-3MA 4HB5267-3MA B-C' JB5436-3MA 4HB5436-3MA B-C' JB5444-3MA 4HB5444-3MA B-C' JB5467-3MA 4HB5467-3MA B-C' JB5636-3MA 4HB5636-3MA B-C' JB5644-3MA 4HB5644-3MA B-C' JB5667-3MA 4HB5667-3MA B-C' JB5836-3MA 4HB5836-3MA B-C' JB5844-3MA 4HB5844-3MA B-C' JB5867-3MA 4HB5867-3MA B-C' JB5836-3NA 4HB5836-3NA B-C' JB5844-3NA 4HB5844-3NA B-C' JB5867-3NA 4HB5867-3NA B-C' JB5936-3NA 4HB5936-3NA B-C' JB5944-3NA 4HB5944-3NA B-C' JB5967-3NA 4HB5967-3NA B-C' JB6036-3NA 4HB6036-3NA B-C' JB6044-3NA 4HB6044-3NA B-C' JB6067-3NA 4HB6067-3NA B-C' JB6136-3NA 4HB6136-3NA B-C' JB6144-3NA 4HB6144-3NA B-C' JB6167-3NA 4HB6167-3NA B-C' JB6236-3NA 4HB6236-3NA B-C' JB6244-3NA 4HB6244-3NA B-C' JB6267-3NA 4HB6267-3NA B-C' JB6336-3NA 4HB6336-3NA B-C' JB6344-3NA 4HB6344-3NA B-C' JB6367-3NA 4HB6367-3NA B-C' JB4736-3TA 4HB4736-3TA C-C' JB4744-3TA 4HB4744-3TA C-C' JB4767-3TA 4HB4767-3TA C-C' JB5036-3TA 4HB5036-3TA C-C' JB5044-3TA 4HB5044-3TA C-C' JB5067-3TA 4HB5067-3TA C-C' JB5236-3TA 4HB5236-3TA C-C' JB5244-3TA 4HB5244-3TA C-C' JB5267-3TA 4HB5267-3TA C-C' JB5436-3TA 4HB5436-3TA C-C' JB5444-3TA 4HB5444-3TA C-C' JB5467-3TA 4HB5467-3TA C-C' JB5636-3TA 4HB5636-3TA C-C' JB5644-3TA 4HB5644-3TA C-C' JB5667-3TA 4HB5667-3TA C-C' JB5836-3TA 4HB5836-3TA C-C' JB5844-3TA 4HB5844-3TA C-C' JB5867-3TA 4HB5867-3TA C-C' JB5836-3UA 4HB5836-3UA C-C' JB5844-3UA 4HB5844-3UA C-C' JB5867-3UA 4HB5867-3UA C-C' JB5936-3UA 4HB5936-3UA C-C' JB5944-3UA 4HB5944-3UA C-C' JB5967-3UA 4HB5967-3UA C-C' JB6036-3UA 4HB6036-3UA C-C' JB6044-3UA 4HB6044-3UA C-C' JB6067-3UA 4HB6067-3UA C-C' JB6136-3UA 4HB6136-3UA C-C' JB6144-3UA 4HB6144-3UA C-C' JB6167-3UA 4HB6167-3UA C-C' JB6236-3UA 4HB6236-3UA C-C' JB6244-3UA 4HB6244-3UA C-C' JB6267-3UA 4HB6267-3UA C-C' JB6336-3UA 4HB6336-3UA C-C' JB6344-3UA 4HB6344-3UA C-C' JB6367-3UA 4HB6367-3UA C-C' JB6436-3UA 4HB6436-3UA C-C' JB6444-3UA 4HB6444-3UA C-C' JB6467-3UA 4HB6467-3UA C-C' JB4736-3JA 4HB4736-3JA C-C'-30% JB4744-3JA 4HB4744-3JA C-C'-30% JB4767-3JA 4HB4767-3JA C-C'-30% JB5036-3JA 4HB5036-3JA C-C'-30% JB5044-3JA 4HB5044-3JA C-C'-30% JB5067-3JA 4HB5067-3JA C-C'-30% JB5236-3JA 4HB5236-3JA C-C'-30% JB5244-3JA 4HB5244-3JA C-C'-30% JB5267-3JA 4HB5267-3JA C-C'-30% JB5436-3JA 4HB5436-3JA C-C'-30% JB5444-3JA 4HB5444-3JA C-C'-30% JB5467-3JA 4HB5467-3JA C-C'-30% JB5636-3JA 4HB5636-3JA C-C'-30% JB5644-3JA 4HB5644-3JA C-C'-30% JB5667-3JA 4HB5667-3JA C-C'-30% JB5836-3JA 4HB5836-3JA C-C'-30% JB5844-3JA 4HB5844-3JA C-C'-30% JB5867-3JA 4HB5867-3JA C-C'-30% JB5836-3KA 4HB5836-3KA C-C'-30% JB5844-3KA 4HB5844-3KA C-C'-30% JB5867-3KA 4HB5867-3KA C-C'-30% JB5936-3KA 4HB5936-3KA C-C'-30% JB5944-3KA 4HB5944-3KA C-C'-30% JB5967-3KA 4HB5967-3KA C-C'-30% JB6036-3KA 4HB6036-3KA C-C'-30% JB6044-3KA 4HB6044-3KA C-C'-30% JB6067-3KA 4HB6067-3KA C-C'-30% JB6136-3KA 4HB6136-3KA C-C'-30% JB6144-3KA 4HB6144-3KA C-C'-30% JB6167-3KA 4HB6167-3KA C-C'-30% JB6236-3KA 4HB6236-3KA C-C'-30% JB6244-3KA 4HB6244-3KA C-C'-30% JB6267-3KA 4HB6267-3KA C-C'-30% JB6336-3KA 4HB6336-3KA C-C'-30% JB6344-3KA 4HB6344-3KA C-C'-30% JB6367-3KA 4HB6367-3KA C-C'-30% JB6436-3KA 4HB6436-3KA C-C'-30% JB6444-3KA 4HB6444-3KA C-C'-30% JB6467-3KA 4HB6467-3KA C-C'-30% Width B1 mm Height H1 mm Distance between wheels E mm

6 Pictures of production steps and machinery 6 TUNAMIC and TUNORMA Oil/Filled Distribution Transformers HIGH VOLTAGE WINDING GEORG CORE CUTTING OIL TRANSFORMER TEST FIELD Examples of our Supplies to several Clients Client: DÉMÁSZ Rt., Hungary Type: TSR 100/22 three-phase oil-immersed distribution transformer Serial number: Rated voltages High Voltage: 22 kv+/-2,5%; +/-5% Low Voltage: 420 / 242,5 V Rated currents HV Winding: 2,62 A LV Winding: 137,5 A Rated power: 100 kva Rated frequency: 50 Hz Vector-group symbol: Dyn5 Guaranteed values: P0: 210 W + 3% Pk: 1475W + 3% Rated impedance voltage: 4,0% 5%; + 10% Type of insulation material: Mineral Oil

7 Oil/Filled Distribution Transformers TUNAMIC and TUNORMA 7 Client: ESAG, Germany Type: 4HB5644-RA05 oil-immersed distribution transformer Serial number: Rated voltages: High voltage: 10,5 kv+/- 2,5; +/- 5% Low voltage: 420 / 242,5 V Rated currents: HV Winding: 22 A LV Winding: 550 A Rated power: 400 kva Rated frequency: 50 Hz Vector group symbol: Dyn5 Guaranteed values: P0: 610 W + 3% Pk: 4600 W + 3% Rated impedance voltage: 4,0% +/- 10 % Type of insulation material: Mineral Oil Painting code: RAL 7033 Client: RWE-enviaM, Germany Type: 4HB5467-4RA05 oil-immersed distribution transformer Serial number: Rated voltages: High voltage : 21 kv+/- 2,5%; +/- 5% Low voltage: 420 / 242,5 V Rated currents: HV Winding: 6,87 A LV Winding: 344 A Rated power: 250 kva Rated frequency: 50 Hz Vector group symbol: Dyn5 Guaranteed values: P0: 425 W + 3% Pk: 3250 W + 3% Rated impedance voltage: 4,0% +/- 10% Type of insulation material: Mineral Oil Painting code: RAL 7033 Client: MMM CABLE, Nigeria Type: 4JB5380-9ZE05 three-phase oil-immersed distribution transformer Serial number: Rated voltages High Voltage: 33 kv+/- 2,5%; +/- 5% Low Voltage: 415 / 240 V Rated currents HV Winding: 3,5 A LV Winding: 278 A Rated power: 200 kva Rated frequency: 50 Hz Vector-group symbol: Dyn11 Guaranteed values: P0: 670 W + 15% Pk: 3570 W + 15% Rated impedance voltage: 4,0% +/- 10% Type of Insulation material: Mineral Oil Painting code: RAL 7033

8 8 TUNAMIC and TUNORMA Oil/Filled Distribution Transformers Quality Management and Environmental Management Certificates TÜV Certificate TÜV Certificate Siemens Transzformátor Kft. H-1214 Budapest II. Rákóczi Ferenc u Tel: (36-1) Fax: (36-1) Siemens Transzformátor Korlátolt Felelôsségû Társaság registered at the Municipal Court of Budapest as Court of Registration, under the registration number

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral

More information

INESING GROUP. Power System Solution

INESING GROUP. Power System Solution INESING GROUP INESING GROUP Power System Solution Power System Solution INESING Group Via Dell'Industria 18B 24040 Casirate D'Adda Italy t: +39 3388263363 f: +39 04381890521 e: info@inesing.com introduction

More information

ABB Transformers Egypt

ABB Transformers Egypt Kamel Elhamy, 2013 ABB Transformers Egypt Our transformers support the systems that keep our world running ABB January 31, 2012 Slide 1 Factory Information Key data 2012 Annual volume 40 MUSD Employees

More information

TGK Prefabricated Substation Technical Data

TGK Prefabricated Substation Technical Data TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024 Fuji Electric Oil immersed Transformer 1 FTU08A1-E-0024 History Fuji Electric (T&D Business) 1923 Established Fuji Electric Manufacturing Co.,Ltd. 1962 Started operation of Chiba factory (transformer)

More information

ABB Ltd. FACTORY IN HANOI

ABB Ltd. FACTORY IN HANOI ABB LTD. ABB Ltd. was originally a JVC between the Vietnamese Transformers Manufacture CTBT and the International Electromechanical group ABB Company was established 1st Sep. 1994 Distribution Transformers

More information

Distribution transformers Efficiency over life-cycle

Distribution transformers Efficiency over life-cycle Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications Distribution The most comprehensive range of solutions for distribution transformer applications Oil Type Single-phase and three-phase transformers for the range above 16 kva and up to 72.5 kv. These units

More information

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA

More information

COMPACT SUBSTATION GUIDE

COMPACT SUBSTATION GUIDE COMPACT SUBSTATION GUIDE Certificate Number FM35831 1 The substation is a compact enclosure consisting of MV switchgear, a transformer and an LV switchboard located in three separate compartments which

More information

Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV

Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV Power IT Liquid Filled Transformers IEC standard, small and medium, rated power 2000kVA, HV 36kV Even our standard solutions are special In almost every place where people live and work you will find at

More information

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type

More information

MEDIUM POWER TRANSFORMER

MEDIUM POWER TRANSFORMER MEDIUM POWER TRANSFORMER MEDIUM POWER TRANSFORMER FROM 3,15 TO 31,5 MVA HIGHEST VOLTAGE FOR MATERIAL 72,5kV GENERAL CHARACTERISTICS Three phase oil-immersed naturally cooled type ONAN medium power transformers.

More information

OLIVER ONLINE VOLTAGE REGULATION

OLIVER ONLINE VOLTAGE REGULATION CAST-RESIN TRANSFORMERS ACCORDING TO IEC/EN 60076, VDE 0532, DIN 42523, DIN EN 50541-1, EU NR. 548/2014 OLIVER ONLINE VOLTAGE REGULATION With Ruhstrat transformers you provide the right voltage for the

More information

Green T.HE. High efficiency Transformers. THE Global specialist in electrical and digital building infrastructures

Green T.HE. High efficiency Transformers. THE Global specialist in electrical and digital building infrastructures Green T.HE High efficiency Transformers THE Global specialist in electrical and digital building infrastructures 2-3 8-18 General features Catalogue pages 19-20 Technical information THE NEW STANDARD

More information

ÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a

ÒÌÃ TRANSFORMERS. ÒÌÃ 1250 kv.a ÒÌÃ TRNSFORMERS ÒÌÃ three-phase oil transformers are intended for transforming of electric energy in networks of power systems and in energy consumer networks. Transformers are designed for indoor or outdoor

More information

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026 TECHNICAL PERTICULAR FOR 1.6 MVA 6.6/0.433 KV SERVICE TRANSFORMER 1.00.00 GENERAL 1.01.00 Service SERVICE 1.02.00 Make ASHOK/VOLTAMP/DANKE/CGL 1.03.00 Type CORE 1.04.00 Location OUTDOOR 1.05.00 Specification

More information

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled 1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R

More information

siemens.com/energy/transformers GEAFOL Cast-Resin Transformers Operating Instructions

siemens.com/energy/transformers GEAFOL Cast-Resin Transformers Operating Instructions siemens.com/energy/transformers GEAFOL Cast-Resin Transformers Operating Instructions Contents Scope 4 Application 4 Description 6 Core 6 Windings 6 Insulation 6 Supports 6 Installing 7 Unloading, transporting,

More information

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS 1 TABLE OF CONTENTS ABOUT SVEL GROUP CAST-RESIN TRANSFORMERS ACCESSORIES AND OPTIONAL EQUIPMENT ENCLOSURE AND HOUSING TESTS AND QUALITY

More information

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS

BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS BUSHINGS AND ACCESSORIES FOR DISTRIBUTION AND POWER TRANSFORMERS COMPANY PROFILE Founded by the Giorgi family in 1967, CEDASPE has been manufacturing bushings and accessories for distribution and power

More information

Powering industry since 1947.

Powering industry since 1947. Powering industry since 1947. Need Power? Get in touch today. 2 EU Compliant, Tier 1 and Tier 2 Distribution & Power Transformers. British heritage, global reputation, world-renowned expertise. Why Bowers?

More information

A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY

A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY ABB Ltd. ABB Ltd. was originally a Joint Venture Company, ABB Transformers Ltd., between the Vietnamese transformers manufacturer CTBT, affiliated with Ministry

More information

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed. tests ( Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed. electrical tests These tests verify contractual

More information

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind

More information

DISTRIBUTION TRANSFORMERS CATALOGUE

DISTRIBUTION TRANSFORMERS CATALOGUE DISTRIBUTION TRANSFORMERS CATALOGUE COMPANY INFORMATION ARTRANS S.A. started off as a small factory in April 2, 1982 located in Mendoza, Argentina. Now, three decades later it is a globally recognized

More information

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar ZREW Transformers Perfection in Detail a company of Rauscher & Stoecklin SERW ZREW Tesar ZREW Your partner for high quality transformers A basic requirement for power transformers is a reliable and efficient

More information

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled 500 kva Pad Mount Transformer - 12470V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled Part #: MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU Page: 1 The MT-PDO-SS-3P-12.47KV-500KVA-208Y.120-FR3-CU

More information

Transformer Stations

Transformer Stations ISO 9001 99-320 Żychlin, ul. Narutowicza 70 www.ftz.com.pl Secretary s Office Tel.: +48 24 285 46 05, Fax: +48 24 285 46 31, zarzad@ftz.com.pl Marketing and Sales Department Tel.: +48 24 285 18 53, Fax:

More information

OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS

OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS (Model Year 2014) OIL LEVEL GAUGES FOR DISTRIBUTION TRANSFORMERS MAGNETIC OIL LEVEL GAUGES (without contacts) Page 5.26. Type IML 80 and IML 99. They are the two cheapest gauges of our range, with aluminium

More information

DRY TYPE TRANSFORMERS

DRY TYPE TRANSFORMERS DRY TYPE Trafotek transformers are made to meet customer requirements in demanding applications. We are specially focused on manufacturing transformers for different types of frequency converters and special

More information

TRANSFORMERS UP TO 750 kv

TRANSFORMERS UP TO 750 kv Electric Co. Ltd. TRANSFORMERS UP TO 750 kv CONTENTS General... 2 Products... 3 Construction...4 Magnetic core... 4 Windings...5 Frame structure... 6 Connections...6 Tap changer and motor drive...7 Tank...

More information

THERMOMETERS For distribution transformers

THERMOMETERS For distribution transformers THERMOMETERS For distribution transformers Page 5.15 : Thermometer MTVT 84 Oil temperature indicator, new concept, fitted with two independent microswirches, range 0...120 C, only with bottom entry rigid

More information

CAST RESIN TRANSFORMERS

CAST RESIN TRANSFORMERS MODEL TAM CAST RESIN - TAM TYPE Epoxy cast resin dry-type transformers are recommended to operate in places that require security, the materials used in its construction are hard to combust and are self-extinguishable

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions ABB a global leader ABB is a global leader in power and automation technologies that

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A Proficient. Innovative. Customer-orientated Transformers up to 8MVA AC/DC Reactors up to 3000A Power Transformers Cast Resin Transformers High-Current Transformers AC/DC Reactors Variable Transformers

More information

Compact Integrated Distribution Substation (CIDS)

Compact Integrated Distribution Substation (CIDS) Compact Integrated Distribution Substation (CIDS) 1- INTRODUCTION SAVE SPACE 2.5m 2 footprint for CIDS up to 630kVA. SAVE THE ENVIRONMENT No SF6, No PCB. SAVE MONEY Save up to 50% from conventional package

More information

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56 T *(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56 TUNISIE TRANSFORMATEUR S.A :ULWWHQE\ M. BOUMALLA Adel Checked by : Mll. LAOUINI Radhia Approved by : M.LARIBI Mohamed Kamel %XVLQHVV'HSDUWPHQW,PP(O+DELE%XUHDX1ƒ%ORF%/HV%HUJHVGXODF$RXLQD

More information

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17 GENERAL INFORMATION SECTION GUIDE SECTION 10 PAGE 1 DESCRIPTION SECTION NUMBER GENERAL INFORMATION... 10 POLE MOUNT TRANSFORMER SINGLE PHASE... 15 PAD MOUNT TRANSFORMER SINGLE PHASE..... 16 POLE MOUNT

More information

AC/DC Arc Furnace and Ladle Furnace Transformers

AC/DC Arc Furnace and Ladle Furnace Transformers AC/DC Arc Furnace and Ladle Furnace Transformers Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard

More information

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets P2 : About Us P3 : Elsewedy Transformers P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers P7 : Technical Data Sheets P8 : Transformer s Outline Drawing P9 : Accessories About Us

More information

Marcel Fortin ing. Hydro Québec Distribution 1

Marcel Fortin ing. Hydro Québec Distribution 1 1 The extrapolation to zero time of the windings average temperature after a heat run test is of prime importance in qualifying a transformer. In order to have correct extrapolation we need: Correct measurement

More information

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA CENTRAL & SOUTH AMERICA MIDDLE EAST &

More information

On-Load Tap changer Type V

On-Load Tap changer Type V Easun - MR Tap changers (P) Ltd., Chennai, India ON-LOAD TAP CHANGER TYPE V Easun - MR Tap Changers (P) Ltd., 612 (232), M.T.H. Road, Tiruninravur, Chennai - 602 024, India Phone : 91-44 - 26390863 ( Hunting

More information

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard

More information

Technical Specification of GECOL. Packaged Transformers

Technical Specification of GECOL. Packaged Transformers GES 26211 Technical Specification of GECOL Packaged Transformers (Revision history) Issued on: Jan. 01, 2007 General Electricity Company of Libya Contents 1 SCOPE AND SERVICE CONDITIONS... 6 1.1 SCOPE...

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

Buchholz Relay MBP Gas and Oil Actuated Relay

Buchholz Relay MBP Gas and Oil Actuated Relay Buchholz Relay MBP Gas and Oil Actuated Relay Reed switches for detection of gas formation and dropping oil level Flap valve to protect in case of excessive high oil flow rate Separated oil and switching

More information

Design specifications

Design specifications Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor

More information

champion series motors

champion series motors Introducing A brand new series of Super Performers Data Sheet champion series motors FRAME SIZE 63-132M TEFC 3 Phase Squirrel Cage Induction Motors Siemens CHAMPION Series Cage Motors are suitable for

More information

PRESENTATION ON STANDARDSDISTRIBUTION TRANSFORMERS BUREAU OF INDIAN STANDARDS BHOPAL

PRESENTATION ON STANDARDSDISTRIBUTION TRANSFORMERS BUREAU OF INDIAN STANDARDS BHOPAL PRESENTATION ON STANDARDSDISTRIBUTION TRANSFORMERS BUREAU OF INDIAN STANDARDS BHOPAL BIS Act WTO Principle on Standard Process for development of Indian Standard Standards on Transformers Detailed provision

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

The construction features of EdM transformers

The construction features of EdM transformers S GENERAL Thanks to the long experience of EdM and to the sophisticated calculation and design techniques, our transformers for distribution, rectifiers and distribution can be realised in a very large

More information

SECTION PADMOUNT TRANSFORMER - OIL FILLED

SECTION PADMOUNT TRANSFORMER - OIL FILLED SECTION 26 12 19.01 PADMOUNT TRANSFORMER - OIL FILLED PART 1 GENERAL 1.1 DESCRIPTION: Padmount Transformers and Insulating Oil with underground primary and secondary connections for use in distribution

More information

GEAFOL cast-resin transformer operating instructions. siemens.com/transformers

GEAFOL cast-resin transformer operating instructions. siemens.com/transformers GEAFOL cast-resin transformer operating instructions siemens.com/transformers Contents Scope 4 Application 4 Description 6 Core 6 Windings 6 Insulation 6 Supports 6 Installing 7 Unloading, transporting,

More information

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration 1TSF14000167/CD LINE ITEM 1: 37,5 KVA 1 PHASE PAD MOUNTED TRANSFORMER, ENVIROTEMP FR3 37.5 KVA, 10 Pad Mounted Transformer, AIMS! TYPE 2 SHRUBLINE insulating fluid 12470 Deita Two position ioadbreak switch

More information

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper GE Grid Solutions PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper PNO bushings are capacitance graded bushings with an oil impregnated paper core. PNO bushings are conform

More information

Transformer Components & Accessories

Transformer Components & Accessories Transformer Components & Accessories Brian Brinson Mechanical Design Manager brian.brinson@spx.com Agenda 1. Standards / Equipment Overview 2. Bushings 3. Arresters 4. Cooling Equipment 5. Instrument Transformers

More information

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

September 2008 TEC, INTELLIGENT MONITORING SYSTEM September 2008 TEC, INTELLIGENT MONITORING SYSTEM ABB BU Transformers - 1-10/9/2008 TEC, philosophy ABB BU Transformers - 2 - TEC was launched by ABB in year 2002 to improve transformers performance. More

More information

Medium voltage fuses - European Fuses

Medium voltage fuses - European Fuses HV Back-up Fuse-Links according to IEC 60 282- HV fuse-links have been used for reliable protection in medium-voltage switchgear and controlgear and systems for decades. They protect apparatus and equipment

More information

PRODUCT RANGE LIGHTING BALLOONS LIGHT TOWERS GENERATORS TRANSFORMERS

PRODUCT RANGE LIGHTING BALLOONS LIGHT TOWERS GENERATORS TRANSFORMERS PRODUCT RANGE LIGHTING BALLOONS LIGHT TOWERS GENERATORS TRANSFORMERS AB POWER MAKİNA SANAYİ VE TİCARET LİMİTED ŞİRKETİ www.abpwr.gen.tr email: ab@abpwr.gen.tr R R R LIGHTING BALLOON SYSTEM Glare Free,

More information

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles BAH-BAHS series Overwiew MGM Electric Motors was established in 1950 as a brake motors manufacturer. MGM is today a world leading manufacturer of this line of products. MGM brake motors are designed and

More information

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280

More information

High-Voltage Fuse Links according to IEC

High-Voltage Fuse Links according to IEC High-Voltage Fuse Links according to IEC 60282- Limitor Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical expertise, innovative

More information

GEMÜ 205 Electrically operated solenoid valve

GEMÜ 205 Electrically operated solenoid valve Electrically operated solenoid valve Features Hermetic separation between medium and actuator In case of power failure operation possible by manual override Standard integral optical position indicator

More information

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for

More information

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand. Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors A Regal Brand www.regalbeloit.com Specifications Range Poles Voltage : Upto 3000 KW : Upto 14 Pole : Upto 11000 Volt Frame : 450 1000

More information

Quality Reliability Flexibility. Trasformatori di potenza in olio Oil Transformers

Quality Reliability Flexibility. Trasformatori di potenza in olio Oil Transformers Quality Trasformatori di potenza in olio Oil Transformers TESAR OIL FILLED TRANSFORMERS: RELIABILITY AND QUALITY NEVER FORGETTING THE ENVIRONMENTAL ASPECTS. Trasformatori trifase a raffreddamento naturale

More information

FITformer distribution transformers

FITformer distribution transformers FITformer distribution s Liquid-immersed distribution s up to 30 MVA siemens.com/xxxxxxxxx siemens.com/lidt Distribution s are key assets at the first and the last step of power. In traditional networks,

More information

Transformers for Power Applications

Transformers for Power Applications Power Applications for Power Applications Tamini designs power transformers for the distribution, transmission and production of electricity from both conventional and renewable sources. The Company s

More information

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR MINING ELECTRIC MOTORS 3KTCR AND 4KTCR Explosion protection Certificate of Conformity: Frame size 71 and 160 Frame size 80, 90, 100, 112, 132 Frame size 180, 200, 225 Frame size 250 Frame size 280 Frame

More information

CAST RESIN TRANSFORMERS

CAST RESIN TRANSFORMERS CAST RESIN TRANSFORMERS 2 CAST RESIN TRANSFORMERS GRAVITY LINE WHO WE ARE SGB-SMIT AT A GLANCE 415 YEARS OF EXPERIENCE Combined, more than Basis for know-how and for know-why More than 2,000 EMPLOYEES

More information

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage High-Voltage Fuse-Links according to VDE 0670 T 402 Hi gh-voltage Limitor Notes 2 Ferraz Shawmut is global leader in fuse-based electrical protection solutions. Our brand is worldwide renowned for technical

More information

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1

Flameproof brake motors. Technical data subject to change without notice. BARTEC VARNOST 1 Flameproof brake motors Technical data subject to change without notice. BARTEC VARNOST 1 2 BARTEC VARNOST Technical data subject to change without notice. Flameproof brake motors 4KTC - General performance

More information

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society Guideline No.: E-07(201501) E-07 TRANSFORMERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

RDLO / RDLO V. Axially Split Volute Casing Pumps. Fields of Application. Bearings. Operating Data. Materials. Design. Shaft Seal. Designation 01 P F

RDLO / RDLO V. Axially Split Volute Casing Pumps. Fields of Application. Bearings. Operating Data. Materials. Design. Shaft Seal. Designation 01 P F Type Series Booklet 1387.5/2--10 RDLO / RDLO V Axially Split Volute Casing Pumps Fields of Application Waterworks, irrigation and drainage pumping stations, power stations, industrial water supply systems,

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Transformers Global product offering

Transformers Global product offering Distributor Line Card Transformers Global product offering ABB is a major transformer manufacturer throughout the world and offers both liquid-filled and dry-type transformers as well as services for complete

More information

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

BALL VALVE SERIES Electric actuator - El-O-matic

BALL VALVE SERIES Electric actuator - El-O-matic BALL VALVE - 715 SERIES Electric actuator - El-O-matic E D C B A L DIMENSIONS: (mm) DN Ø A L B EL C D E Kg 15 1/2" 54,0 108 21,5 EL55 61,5 316,5 95 8,45 20 3/4" 60,0 117 26 EL55 66 321 95 8,95 25 1" 65,0

More information

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society Guideline No.: E-07(201610) E-07 TRANSFORMERS Issued date: October 28,2016 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements

MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements Dehydrating Breather Technical data Product variants This technical document contains detailed information about the technical properties of the product. If you would like to place an order, please use

More information

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear Power Systems PU HYOSUNG Standard High-voltage Switchgear ProSWGR Medium Voltage Metal-clad Switchgear Power & Industrial Systems Performance Group Hyosung Power Systems has been continuously enhancing

More information

Flow Meter Terminal Boxes

Flow Meter Terminal Boxes Shutter Flow Meter Terminal Boxes Shutter Flow meter Terminal boxes 02 07 11 1 Shutter Valve DAROC Description and general specifications Production range and operating conditions Operation Installation,

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

ANSI Switchboard Meters

ANSI Switchboard Meters ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged

More information

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00 INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR469100 BR25AT REV00 I CONTENT: 1 SAFETY 1.1 Safety instructions 1 1.2 Specified applications 1 1.3 Safety notes on the equipment operation 1 2 BR 25

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION CLC/TS 50537-3 SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION February 2010 ICS 29.180; 45.060.10 English version Railway applications - Mounted parts of the traction transformer

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

PRODUCT CATALOGUE. Transformers accessories

PRODUCT CATALOGUE. Transformers accessories PRODUCT CATALOGUE Transformers accessories TR ANSFORME R S ACCESSORIES Table of contents 04 07 De-energized tap-changers 08 13 Bushings 14 23 Measurement and safety devices 24 28 Metal accessories 29 Certificates

More information

Buchholz Relays Series RR - RRF - GQ

Buchholz Relays Series RR - RRF - GQ Buchholz Relays Series RR - RRF - GQ Catalogue N : 04RRCATR03-E Revision: 03 of 29.06.2004 04RRGENR05-E Buchholz Relays "Custos" Series RR, RRF, GQ 1 of 4 Function and construction, functional and operating

More information

DRY TYPE TRANSFORMERS

DRY TYPE TRANSFORMERS DRY TYPE TRANSFORMERS Single-phase, Three-phase/Single-phase, Three-phase/Two-phase,Three-phase 1.1 kv to 7.2kV Class Dry Type Transformers Transformers meant to be installed in a dry and air conditioned

More information

HPS EnduraCoil. Cast Resin Transformer

HPS EnduraCoil. Cast Resin Transformer HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality

More information

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00 CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00 1 HISTORY INESING SRL is a dynamic and modern company, very well known in the design and production of dry type (cast resin ) transformer up to 36kV -10MVA,

More information

Product features & Overview. N1 - N4 A Rotary and part-turn actuators

Product features & Overview. N1 - N4 A Rotary and part-turn actuators Product features & Overview N1 - Rotary and part-turn actuators 20 N1 - Rotary and part-turn actuators Rotary and part-turn actuators Product features Wide torque range Wide selection of output shafts

More information

Transform. energy. Liquid immersed distribution transformers. Up to 5000 kva Up to 72,5 kv

Transform. energy. Liquid immersed distribution transformers. Up to 5000 kva Up to 72,5 kv We Transform energy Liquid immersed distribution transformers Up to 5000 kva Up to 72,5 kv Liquid immersed distribution transformers Diseño Gráfico: Departamento de Marketing y Comunicación de IMEFY S.L.