1 16.0 Heat Pumps Ruud Achiever Series Heat Pumps Efficiencies up to 15.5 S/13 /10.00 Nominal Sizes 1.5 to 5 Ton [5.28 to 17.6 kw] Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your Contractor for details or visit Attractive, louvered wrap around jacket protects coil from weather extremes and yard hazards. Top grille is steel reinforced for extra strength. Cabinet is powder painted for all weather protection. Four sided outdoor coil design allows compressor operation with access panel removed. Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation. Combination Grille/Motor Mount secures the fan motor to the underside of the discharge grille. All controls are accessible by removing one service panel. Removable top grille provides access to the outdoor fan motor and outdoor coil. Compressor compartment offers additional protection from the elements and reduces operating noise. Single speed, 8-pole fan motor is designed for quieter, energysaving operation. Non-cycling reversing valve and demand defrost. All models meet or exceed a 1000-hour salt spray test per ASTM B117 Standard Practice for Operating Salt Spray Testing Apparatus. Rely on Ruud. FORM NO. P REV. 1

2 Table of Contents TABLE OF CONTENTS Model Features...3 Model Number Identification...4 Accessories...4 Scroll Compressor Electrical & Physical Data...27 Dimensions...28 Refrigerant Line Size Information...29 Limited Warranty Rely on Ruud.

3 Model Features All controls and compressor are accessible for servicing by removal of the service panel. Drawn Painted Base Pan. Model Features Series Heat Pump 1. Scroll compressor is hermetically sealed and incorporates internal high temperature motor overload protection, and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Copper Tube/Aluminum Fin CoilsBoth indoor and outdoor coils. 3. Strong, Attractive CabinetConstructed of powder painted steel. Louvered design protects the coil from damage. 4. Internal Check ValveProvides for more quiet refrigerant metering. 5. Enhanced Compressor ProtectionFeatures an enhanced defrost control, auto-reset high pressure control, and auto-reset low pressure control to provide compressor protection under abnormally high head pressure conditions (outdoor fan failure, restriction, dirty coil, etc.) or abnormally low suction pressure conditions (restrictions, TEV failure, loss of charge, indoor blower failure, etc.) while eliminating nuisance tripping sometimes experienced with conventional control systems. 6. Drawn Painted Base PanFor extra corrosion resistance and sound reduction. 7. Demand Defrost ControlProvides complete defrost when defrost is required. 8. Non-Cycling Reversing ValveEliminates discharge noises on each heating cycle. 9. Hot Gas MufflerReduces noise in heating cycle. 10. Bi-Directional Filter DrierStandard on all models (shipped not installed). 11. Service valves are standard on all models. 12. Refrigerant MeteringTEV accurately meter refrigerant into indoor and outdoor coils. 13. The has a 10 year limited compressor warranty. 14. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. 15. Coil design permits compressor operation with the access panel removed. 16. Control box is fully accessible in the upper part of the cabinet, just under the access panel. 17. Power and control wiring are kept separate. 18. Every unit is factory charged and tested. Rely on Ruud. 3

4 Model I.D./Accessories/Compressor Model Number Identification U P Q L J A Z RUUD REMOTE HEAT PUMP Q = 15 S DESIGN SERIES L = R-410A COOLING CAPACITY 018 = 1 R [5.28 kw] 024 = R [7.03 kw] 030 = R [8.79 kw] 036/037 = R [10.55 kw] 043 = 42,000 R [12.31 kw] 048/049 = 4 R [14.07 kw] 056 = 56,000 R [16.41 kw] 060 = 60,000 R [17.58 kw] ELECTRICAL DESIGNATION J = 208/230V-1-60 VARIATIONS A SERIES = FULL-FEATURED COOLING CONNECTION FITTING Z = SWEAT W/SCROLL Accessories Low Ambient Control (RXAD-A08) Crankcase Heater Heat Pump Monitor (RXPM-B01) Hard Start Components Heat Pump Thermostat Warning Light Kit Blower Time Delay Control (RXMD-C04). Fossil Fuel KitsRXPF-01 RXPF-02 Thermostats 200-Series * Programmable 300-Series * Deluxe Programmable 400-Series * Special Applications/ Programmable 500-Series * Communicating/ Programmable Ruud Heat Pump System For all season home comfort, performance and energy conser - vation, choose a Ruud Series Heat Pump and a RHSL, RHLL, or RHKL Series. More than a reverse cycle air conditioner, it s a specially designed combination Winter/Summer comfort system using a single indoor coil for heating and cooling. To choose an designed for use with the Heat Pumps, refer to the Tables and/or the air handler specification sheet. * Photos are representative. Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T Scroll Compressor The scroll compressor is the key to efficiency for this Ruud model. It s the latest in high-efficiency compressor technology. The advanced scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination. The scroll compressor also has low start torque, eliminating start problems in the field. And its unique design enables the heat pumps to perform efficiently, quietly and dependably. 4 Rely on Ruud.

5 AHRI Standard Conditions 018JAZ RHLL-HM2417(RCSL-H*2417) ➀ RCFL-H*2417 RCFL-H*2417(RGFE-06(E,N)MCKS) RCFL-H*2417(RGFE-07(E,N)MCKS) RCFL-H*2417(RGFG-06EMCKS) RCFL-H*2417(RGFG-07EMCKS) RCFL-H*2417(RGGE-06(E,N)MCKS) RCFL-H*2417(RGGE-07(E,N)MCKS) RCFL-H*2417(RGJF-06(E,N)MCKS) RCFL-H*2417(RGJF-07(E,N)MCKS) RCFL-H*2417(RGLE-07(E,N)AMKR) RCFL-H*2417(RGLT-07(E,N)AMKR) RCFL-H*2417(RGLT-07?AMK?) RCFL-H*2417(RGPE-05(E,N)BMKR) RCFL-H*2417(RGPE-07(E,N)AMKR) RCFL-H*2417(RGPT-05(E,N)BMKR) RCFL-H*2417(RGPT-05?BMK?) RCFL-H*2417(RGPT-07(E,N)AMKR) RCFL-H*2417(RGPT-07?AMK?) RCFL-H*2417(RGRM-04(E,N)MAES) RCFL-H*2417(RGRM-06(E,N)MAES) RCFL-H*2417(RGRM-07(E,N)MAES) RCFL-H*2417(RGTM-06(E,N)MAES) RCFL-H*2417(ROCA-070E03) RCFL-H*2417(ROLA-070E03) RHKL-HM2417(RCSL-H*2417) RHSL-HM1817(RCSL-H*2417) 18,700 [5.5] 1 [5.3] 18,300 18,500 18, ,700 [5.5] 18,300 18,700 [5.5] 18,300 18,500 18,700 [5.5] 18,700 [5.5] 18,300 18,700 [5.5] 18,700 [5.5] 18,700 [5.5] 18,700 [5.5] 18,700 [5.5] 18, ,600 18,700 [5.5] 18, ,700 [5.5] 18,100 [5.3] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 14,400 [4.2] 13,900 [4.1] 13,800 14,100 [4.1] 13,800 14,000 [4.1] 14,400 [4.2] 13,800 14,400 [4.2] 13,800 14,100 [4.1] 14,400 [4.2] 14,400 [4.2] 13,800 14,400 [4.2] 14,400 [4.2] 14,400 [4.2] 14,400 [4.2] 14,400 [4.2] 13,800 14,000 [4.1] 14,300 [4.2] 14,400 [4.2] 14,100 [4.1] 14,000 [4.1] 14,400 [4.2] 13,700 4,300 4,300 4,500 4,400 4,500 4,400 4,300 4,500 4,300 4,500 4,400 4,300 4,300 4,500 4,300 4,300 4,300 4,300 4,300 4,500 4,400 4,300 4,300 4,400 4,400 4,300 4,400 S [307] 650 [307] 575 [271] 600 [283] 575 [271] 600 [283] 625 [295] 575 [271] 625 [295] 575 [271] 600 [283] 675 [319] 675 [319] 575 [271] 625 [295] 650 [307] 650 [307] 625 [295] 625 [295] 575 [271] 600 [283] 625 [295] 625 [295] 600 [283] 600 [283] 650 [307] 600 [283] AHRI Heating Performance (70 F [21 C] ) Air 17,200 [5.0] 16,600 16,600 16,600 16,600 16,700 16,600 16,600 16,600 16,600 16,600 16,700 16,700 16,600 16,600 16,700 16,700 16,700 16,700 16,700 16,700 16,800 16,700 16,600 16,700 16,700 17,000 [5.0] Air 10,500 10,000 10,000 10,000 10, Rely on Ruud. 5

6 AHRI Standard Conditions (cont.) 024JAZ RHLL-HM2417(RCSL-H*2417) ➀ RCFL-H*2417 RCFL-H*2417(RGFE-06(E,N)MCKS) RCFL-H*2417(RGFE-07(E,N)MCKS) RCFL-H*2417(RGFG-06EMCKS) RCFL-H*2417(RGFG-07EMCKS) RCFL-H*2417(RGGE-06(E,N)MCKS) RCFL-H*2417(RGGE-07(E,N)MCKS) RCFL-H*2417(RGJF-06(E,N)MCKS) RCFL-H*2417(RGJF-07(E,N)MCKS) RCFL-H*2417(RGLE-07(E,N)AMKR) RCFL-H*2417(RGLT-07(E,N)AMKR) RCFL-H*2417(RGLT-07?AMK?) RCFL-H*2417(RGPE-05(E,N)BMKR) RCFL-H*2417(RGPE-07(E,N)AMKR) RCFL-H*2417(RGPT-05(E,N)BMKR) RCFL-H*2417(RGPT-05?BMK?) RCFL-H*2417(RGPT-07(E,N)AMKR) RCFL-H*2417(RGPT-07?AMK?) RCFL-H*2417(RGRM-04(E,N)MAES) RCFL-H*2417(RGRM-06(E,N)MAES) RCFL-H*2417(RGRM-07(E,N)MAES) RCFL-H*2417(RGTM-06(E,N)MAES) RCFL-H*2417(RHWB-04WMX36A) RCFL-H*2417(ROCA-070E03) RCFL-H*2417(ROCA-070E04) RCFL-H*2417(ROLA-070E03) RCFL-H*2417(ROLA-070E04) 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 17,950 [5.3] 17,300 18,300 18,300 18,300 18,300 18,300 18,300 18,100 [5.3] 6,050 6,300 5,900 [1.7] 5,900 [1.7] 5,900 [1.7] 5,900 [1.7] 5,900 [1.7] 5,900 [1.7] 5,900 [1.7] 6,200 6,300 S [378] 800 [378] 800 [378] 725 [342] 800 [378] 800 [378] 825 [389] 800 [378] 825 [389] 800 [378] 800 [378] 850 [401] 850 [401] 800 [378] 825 [389] 850 [401] 850 [401] 850 [401] 850 [401] 800 [378] 825 [389] 850 [401] 750 [354] 825 [389] 800 [378] 800 [378] 800 [378] 725 [342] AHRI Heating Performance (70 F [21 C] ) Air 23,000 [6.7] 23,000 [6.7] 22,800 [6.7] Air 13,900 [4.1] 12,900 13,400 13,300 13,400 13,400 13,300 13,300 13,300 13,300 13,300 14,000 [4.1] 14,000 [4.1] 13,300 13,300 13,500 13,500 13,400 13,400 13,400 13,400 13,600 13,200 13,500 13,300 13,300 13,300 13, Rely on Ruud.

7 AHRI Standard Conditions (cont.) 024JAZ 030JAZ RHKL-HM2417(RCSL-H*2417) RHSL-HM2417(RCSL-H*2417) RHLL-HM3617(RCSL-H*3617) ➀ RCFL-H*3617 RCFL-H*3617(RGFE-06(E,N)MCKS) RCFL-H*3617(RGFE-07(E,N)MCKS) RCFL-H*3617(RGFG-06EMCKS) RCFL-H*3617(RGFG-07EMCKS) RCFL-H*3617(RGGE-06(E,N)MCKS) RCFL-H*3617(RGGE-07(E,N)MCKS) RCFL-H*3617(RGJF-06(E,N)MCKS) RCFL-H*3617(RGJF-07(E,N)MCKS) RCFL-H*3617(RGLE-07(E,N)AMKR) RCFL-H*3617(RGLT-07(E,N)AMKR) RCFL-H*3617(RGLT-07?AMK?) RCFL-H*3617(RGPE-05(E,N)BMKR) RCFL-H*3617(RGPE-07(E,N)AMKR) RCFL-H*3617(RGPT-05(E,N)BMKR) RCFL-H*3617(RGPT-05?BMK?) RCFL-H*3617(RGPT-07(E,N)AMKR) RCFL-H*3617(RGPT-07?AMK?) RCFL-H*3617(RGRM-04(E,N)MAES) RCFL-H*3617(RGRM-06(E,N)MAES) RCFL-H*3617(RGRM-07(E,N)MAES) RCFL-H*3617(RGTM-06(E,N)MAES) RCFL-H*3617(RHWB-04WMX36A) RCFL-H*3617(RHWB-06WMX48A) RCFL-H*3617(ROCA-070E03) 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 18,300 17,700 21, ,100 22,100 22,100 22, ,300 5,900 [1.7] 8,150 7,900 7,900 7,900 7,900 8,100 8,300 S [389] 800 [378] 1,025 [484] 925 [437] 1,025 [484] 925 [437] 1,025 [484] 1,025 [484] 925 [437] 925 [437] 900 [425] 900 [425] 1,050 [495] 1,050 [495] 1,050 [495] 1,050 [495] 925 [437] 950 [448] 900 [425] 1,025 [484] 950 [448] AHRI Heating Performance (70 F [21 C] ) Air 23,000 [6.7] 29,000 27,600 [8.1] Air 13,300 13,700 1 [5.3] 17,000 [5.0] 17,800 17,800 17,700 17,800 17,800 17,800 1 [5.3] 17,700 17, Rely on Ruud. 7

8 AHRI Standard Conditions (cont.) 030JAZ RCFL-H*3617(ROCA-070E04) RCFL-H*3617(ROLA-070E03) RCFL-H*3617(ROLA-070E04) RCFL-H*3621 RCFL-H*3621(RGFE-06(E,N)MCKS) RCFL-H*3621(RGFE-07(E,N)MCKS) RCFL-H*3621(RGFE-09(E,N)ZCMS) RCFL-H*3621(RGFE-10(E,N)ZCMS) RCFL-H*3621(RGFG-06EMCKS) RCFL-H*3621(RGFG-07EMCKS) RCFL-H*3621(RGFG-09EZCMS) RCFL-H*3621(RGFG-10EZCMS) RCFL-H*3621(RGGE-06(E,N)MCKS) RCFL-H*3621(RGGE-07(E,N)MCKS) RCFL-H*3621(RGGE-09(E,N)ZCMS) RCFL-H*3621(RGGE-10(E,N)ZCMS) RCFL-H*3621(RGJF-06(E,N)MCKS) RCFL-H*3621(RGJF-07(E,N)MCKS) RCFL-H*3621(RGJF-09(E,N)ZCMS) RCFL-H*3621(RGJF-10(E,N)ZCMS) RCFL-H*3621(RGLE-07(E,N)AMKR) RCFL-H*3621(RGLE-07(E,N)BRQR) RCFL-H*3621(RGLE-07?BRQ?) RCFL-H*3621(RGLE-10(E,N)BRMR) RCFL-H*3621(RGLT-07(E,N)AMKR) RCFL-H*3621(RGLT-07?AMK?) RCFL-H*3621(RGLT-07(E,N)BRQR) RCFL-H*3621(RGLT-07?BRQ?) RCFL-H*3621(RGLT-10(E,N)BRMR) 30,400 30, F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air ,000 22,000 22,000 8,600 8,600 8,600 S [425] 900 [425] 1,025 [484] 975 [460] 975 [460] 900 [425] 925 [437] 1,025 [484] 925 [437] 1,025 [484] 1,025 [484] 925 [437] 925 [437] 1,050 [495] 925 [437] 925 [437] 975 [460] 975 [460] 975 [460] AHRI Heating Performance (70 F [21 C] ) Air ,600 [8.1] [8.2] Air 17,700 17,000 [5.0] 17,800 17,800 17,800 17,800 17,700 17,400 17, Rely on Ruud.

9 AHRI Standard Conditions (cont.) 030JAZ RCFL-H*3621(RGLT-10?BRM?) RCFL-H*3621(RGPE-05(E,N)BMKR) RCFL-H*3621(RGPE-07(E,N)AMKR) RCFL-H*3621(RGPE-07(E,N)BRQR) RCFL-H*3621(RGPE-10(E,N)BRMR) RCFL-H*3621(RGPT-07(E,N)AMKR) RCFL-H*3621(RGPT-07?AMK?) RCFL-H*3621(RGPT-07(E,N)BRQR) RCFL-H*3621(RGPT-07?BRQ?) RCFL-H*3621(RGPT-10?BRM?) RCFL-H*3621(RGRM-04(E,N)MAES) RCFL-H*3621(RGRM-06(E,N)MAES) RCFL-H*3621(RGRM-07(E,N)MAES) RCFL-H*3621(RGRM-07(E,N)YBGS) RCFL-H*3621(RGRM-09(E,N)ZAJS) RCFL-H*3621(RGRM-10(E,N)ZAJS) RCFL-H*3621(RGTM-06(E,N)MAES) RCFL-H*3621(RGTM-07(E,N)RBGS) RCFL-H*3621(RGTM-09(E,N)ZAJS) RCFL-H*3621(RHWB-04WMX36A) RCFL-H*3621(RHWB-06WMX48A) RCFL-H*3621(ROCA-070E03) RCFL-H*3621(ROCA-070E04) RCFL-H*3621(ROLA-070E03) RCFL-H*3621(ROLA-070E04) RCFL-H*3621(ROLA-115E05) RHKL-HM3617(RCSL-H*3617) RHSL-HM3017(RCSL-H*3617) 30,200 30,200 30,200 30,200 30, F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 22, ,100 22,100 22,000 22,000 22, , ,900 7,900 7,800 8,100 8,100 8,600 S [460] 900 [425] 900 [425] 900 [425] 900 [425] 1,050 [495] 1,050 [495] 975 [460] 975 [460] 975 [460] 925 [437] 950 [448] 1,050 [495] 950 [448] 1,025 [484] 900 [425] 950 [448] 975 [460] 1,025 [484] 975 [460] 900 [425] 1,025 [484] 1,050 [495] 1,025 [484] AHRI Heating Performance (70 F [21 C] ) Air [8.2] Air 17,400 17,400 17,800 17,800 17,700 1 [5.3] 17,800 17,800 17, Rely on Ruud. 9

10 AHRI Standard Conditions (cont.) 036JAZ RHLL-HM3617(RCSL-H*3617) ➀ RCFL-H*3617 RCFL-H*3617(RGFE-06(E,N)MCKS) RCFL-H*3617(RGFE-07(E,N)MCKS) RCFL-H*3617(RGFG-06EMCKS) RCFL-H*3617(RGFG-07EMCKS) RCFL-H*3617(RGGE-06(E,N)MCKS) RCFL-H*3617(RGGE-07(E,N)MCKS) RCFL-H*3617(RGJF-06(E,N)MCKS) RCFL-H*3617(RGJF-07(E,N)MCKS) RCFL-H*3617(RGLE-07(E,N)AMKR) RCFL-H*3617(RGLT-07(E,N)AMKR) RCFL-H*3617(RGLT-07?AMK?) RCFL-H*3617(RGPE-05(E,N)BMKR) RCFL-H*3617(RGPE-07(E,N)AMKR) RCFL-H*3617(RGPT-05(E,N)BMKR) RCFL-H*3617(RGPT-05?BMK?) RCFL-H*3617(RGPT-07(E,N)AMKR) RCFL-H*3617(RGPT-07?AMK?) RCFL-H*3617(RGRM-04(E,N)MAES) RCFL-H*3617(RGRM-06(E,N)MAES) RCFL-H*3617(RGTM-06(E,N)MAES) RCFL-H*3617(RHWB-04WMX36A) RCFL-H*3617(RHWB-06WMX48A) RCFL-H*3617(ROCA-070E03) RCFL-H*3617(ROCA-070E04) RCFL-H*3617(ROLA-070E03) RCFL-H*3617(ROLA-070E04) 35,200 [10.3] 36,200 [10.6] 35,200 [10.3] 36,200 [10.6] 36,200 [10.6] 35,400 35,200 [10.3] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 24,100 25,500 [7.5] 26,400 25,500 [7.5] 26, ,700 [7.5] 26, ,300 9,800 9,800 10,200 S 1,075 [507] 1,150 [543] 1,150 [543] 1,075 [507] 1,150 [543] AHRI Heating Performance (70 F [21 C] ) Air 35,200 [10.3] 36,200 [10.6] 35,200 [10.3] 36,200 [10.6] 36,200 [10.6] 35,400 35,200 [10.3] Air 22,800 [6.7] Rely on Ruud.

11 AHRI Standard Conditions (cont.) 036JAZ RCFL-H*3621 RCFL-H*3621(RGFE-06(E,N)MCKS) RCFL-H*3621(RGFE-07(E,N)MCKS) RCFL-H*3621(RGFE-09(E,N)ZCMS) RCFL-H*3621(RGFE-10(E,N)ZCMS) RCFL-H*3621(RGFG-06EMCKS) RCFL-H*3621(RGFG-07EMCKS) RCFL-H*3621(RGFG-09EZCMS) RCFL-H*3621(RGFG-10EZCMS) RCFL-H*3621(RGGE-06(E,N)MCKS) RCFL-H*3621(RGGE-07(E,N)MCKS) RCFL-H*3621(RGGE-09(E,N)ZCMS) RCFL-H*3621(RGGE-10(E,N)ZCMS) RCFL-H*3621(RGJF-06(E,N)MCKS) RCFL-H*3621(RGJF-07(E,N)MCKS) RCFL-H*3621(RGJF-09(E,N)ZCMS) RCFL-H*3621(RGJF-10(E,N)ZCMS) RCFL-H*3621(RGLE-07(E,N)AMKR) RCFL-H*3621(RGLE-07(E,N)BRQR) RCFL-H*3621(RGLE-07?BRQ?) RCFL-H*3621(RGLE-10(E,N)BRMR) RCFL-H*3621(RGLT-07(E,N)AMKR) RCFL-H*3621(RGLT-07?AMK?) RCFL-H*3621(RGLT-07(E,N)BRQR) RCFL-H*3621(RGLT-07?BRQ?) RCFL-H*3621(RGLT-10(E,N)BRMR) RCFL-H*3621(RGLT-10?BRM?) RCFL-H*3621(RGPE-05(E,N)BMKR) 35,400 36,200 [10.6] 35,400 36,200 [10.6] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 24,100 25,700 [7.5] 26, ,700 [7.5] 26, ,300 9,800 9,800 S ,075 [507] 1,150 [543] 1,150 [543] AHRI Heating Performance (70 F [21 C] ) Air 35,400 36,200 [10.6] 35,400 36,200 [10.6] Air 22,800 [6.7] Rely on Ruud. 11

12 AHRI Standard Conditions (cont.) 036JAZ RCFL-H*3621(RGPE-07(E,N)AMKR) RCFL-H*3621(RGPE-07(E,N)BRQR) RCFL-H*3621(RGPE-10(E,N)BRMR) RCFL-H*3621(RGPT-05(E,N)BMKR) RCFL-H*3621(RGPT-05?BMK?) RCFL-H*3621(RGPT-07(E,N)AMKR) RCFL-H*3621(RGPT-07?AMK?) RCFL-H*3621(RGPT-07(E,N)BRQR) RCFL-H*3621(RGPT-07?BRQ?) RCFL-H*3621(RGPT-10?BRM?) RCFL-H*3621(RGRM-04(E,N)MAES) RCFL-H*3621(RGRM-06(E,N)MAES) RCFL-H*3621(RGRM-09(E,N)ZAJS) RCFL-H*3621(RGRM-10(E,N)ZAJS) RCFL-H*3621(RGTM-06(E,N)MAES) RCFL-H*3621(RGTM-07(E,N)RBGS) RCFL-H*3621(RGTM-09(E,N)ZAJS) RCFL-H*3621(RHWB-04WMX36A) RCFL-H*3621(RHWB-06WMX48A) RCFL-H*3621(ROCA-070E03) RCFL-H*3621(ROCA-070E04) RCFL-H*3621(ROLA-070E03) RCFL-H*3621(ROLA-070E04) RCFL-H*3621(ROLA-115E05) RHKL-HM3617(RCSL-H*3617) RHSL-HM3617(RCSL-H*3617) RHSL-HM3621(RCSL-H*3621) 35,200 [10.3] 35,200 [10.3] 35,400 35,400 35,200 [10.3] 35,200 [10.3] 35, F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 25,700 [7.5] 25,700 [7.5] 25,700 [7.5] 25,600 [7.5] 25,500 [7.5] 26, ,700 [7.5] 10,200 10,200 10,200 10,200 10,000 10,000 S 1,075 [507] 1,075 [507] 1,075 [507] 1,150 [543] 1,025 [484] 1,125 [531] 1,100 [519] 1,150 [543] 1,100 [519] 1,100 [519] AHRI Heating Performance (70 F [21 C] ) Air 35,200 [10.3] 35,200 [10.3] 35,400 35,400 35,200 [10.3] 35,200 [10.3] 35, Air 23, Rely on Ruud.

13 AHRI Standard Conditions (cont.) 037JAZ RHLL-HM3617(RCSL-H*3617) ➀ RCFL-H*3617 RCFL-H*3617(RGGE-06(E,N)MCKS) RCFL-H*3617(RGGE-07(E,N)MCKS) RCFL-H*3617(RGJF-06(E,N)MCKS) RCFL-H*3617(RGJF-07(E,N)MCKS) RCFL-H*3617(RGLE-07(E,N)AMKR) RCFL-H*3617(RGLT-07(E,N)AMKR) RCFL-H*3617(RGLT-07?AMK?) RCFL-H*3617(RGPE-05(E,N)BMKR) RCFL-H*3617(RGPE-07(E,N)AMKR) RCFL-H*3617(RGPT-05(E,N)BMKR) RCFL-H*3617(RGPT-05?BMK?) RCFL-H*3617(RGPT-07(E,N)AMKR) RCFL-H*3617(RGPT-07?AMK?) RCFL-H*3617(RHWB-04WMX36A) RCFL-H*3617(RHWB-06WMX48A) RCFL-H*3617(ROCA-070E03) RCFL-H*3617(ROCA-070E04) RCFL-H*3617(ROLA-070E03) RCFL-H*3617(ROLA-070E04) RCFL-H*3617+RXMD-C04 RCFL-H*3621(RGFE-09(E,N)ZCMS) RCFL-H*3621(RGFE-10(E,N)ZCMS) RCFL-H*3621(RGFG-09EZCMS) RCFL-H*3621(RGFG-10EZCMS) RCFL-H*3621(RGGE-06(E,N)MCKS) RCFL-H*3621(RGGE-07(E,N)MCKS) 36,200 [10.6] 36,200 [10.6] 36,800 36, F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 26,450 25,300 26,700 26,800 [7.9] ,700 26,700 25,300 26,700 26,800 [7.9] 26,700 26,700 10,150 10,500 9,800 10,300 10,300 10,500 9,800 S ,150 [543] 1,075 [507] 1,150 [543] 1,150 [543] 1,150 [543] 1,150 [543] 1,075 [507] AHRI Heating Performance (70 F [21 C] ) Air 33,000 [9.7] 33,600 33,600 33,600 Air Rely on Ruud. 13

14 AHRI Standard Conditions (cont.) 037JAZ RCFL-H*3621(RGGE-09(E,N)ZCMS) RCFL-H*3621(RGGE-10(E,N)ZCMS) RCFL-H*3621(RGJF-06(E,N)MCKS) RCFL-H*3621(RGJF-07(E,N)MCKS) RCFL-H*3621(RGJF-09(E,N)ZCMS) RCFL-H*3621(RGJF-10(E,N)ZCMS) RCFL-H*3621(RGLE-07(E,N)AMKR) RCFL-H*3621(RGLE-07(E,N)BRQR) RCFL-H*3621(RGLE-07?BRQ?) RCFL-H*3621(RGLE-10(E,N)BRMR) RCFL-H*3621(RGLT-07(E,N)AMKR) RCFL-H*3621(RGLT-07?AMK?) RCFL-H*3621(RGLT-07(E,N)BRQR) RCFL-H*3621(RGLT-07?BRQ?) RCFL-H*3621(RGLT-10(E,N)BRMR) RCFL-H*3621(RGLT-10?BRM?) RCFL-H*3621(RGPE-05(E,N)BMKR) RCFL-H*3621(RGPE-07(E,N)AMKR) RCFL-H*3621(RGPE-07(E,N)BRQR) RCFL-H*3621(RGPE-10(E,N)BRMR) RCFL-H*3621(RGPT-05(E,N)BMKR) RCFL-H*3621(RGPT-05?BMK?) RCFL-H*3621(RGPT-07(E,N)AMKR) RCFL-H*3621(RGPT-07?AMK?) RCFL-H*3621(RGPT-07(E,N)BRQR) RCFL-H*3621(RGPT-07?BRQ?) RCFL-H*3621(RGPT-10?BRM?) RCFL-H*3621(RGRM-09(E,N)ZAJS) 36,800 36,800 37,000 37,000 37,000 36,800 36,800 37,000 37,000 37,200 [10.9] 37,200 [10.9] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 27,000 [7.9] 26,700 27,000 [7.9] 26,700 26,700 27,200 [8.0] 27,200 [8.0] 27,100 [7.9] 26,900 [7.9] 26,900 [7.9] 26,800 [7.9] 27,200 [8.0] 27,200 [8.0] 26,700 26,700 27,000 [7.9] 27,000 [7.9] 26,800 [7.9] 9,800 9,800 9,800 9,800 9,800 9,800 9,800 10,200 10,200 9,800 S ,150 [543] 1,150 [543] AHRI Heating Performance (70 F [21 C] ) Air 33,800 [9.9] 33,600 33,600 33,600 33,600 33,600 33,600 33,600 Air 22,000 22,000 22, Rely on Ruud.

15 AHRI Standard Conditions (cont.) 037JAZ 042JAZ RCFL-H*3621(RGRM-10(E,N)ZAJS) RCFL-H*3621(RGTM-07(E,N)RBGS) RCFL-H*3621(RGTM-09(E,N)ZAJS) RCFL-H*3621(RHWB-04WMX36A) RCFL-H*3621(RHWB-06WMX48A) RCFL-H*3621(ROCA-070E03) RCFL-H*3621(ROCA-070E04) RCFL-H*3621(ROLA-070E03) RCFL-H*3621(ROLA-070E04) RCFL-H*3621(ROLA-115E05) RCFL-H*3621+RXMD-C04 RHKL-HM3617(RCSL-H*3617) RHSL-HM3617(RCSL-H*3617) RHSL-HM3621(RCSL-H*3621) RCFL-H*4821 RCFL-H*4821(RGFG-09EZCMS) RCFL-H*4821(RGFG-10EZCMS) RCFL-H*4821(RGGE-09(E,N)ZCMS) RCFL-H*4821(RGGE-10(E,N)ZCMS) RCFL-H*4821(RGJF-09(E,N)ZCMS) RCFL-H*4821(RGJF-10(E,N)ZCMS) RCFL-H*4821(RGLE-07(E,N)BRQR) RCFL-H*4821(RGLE-07?BRQ?) RCFL-H*4821(RGLE-10(E,N)BRMR) RCFL-H*4821(RGLT-07(E,N)AMKR) RCFL-H*4821(RGLT-07?AMK?) RCFL-H*4821(RGLT-07(E,N)BRQR) RCFL-H*4821(RGLT-07?BRQ?) 36,800 37,000 37,000 36,800 37, F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 27,000 [7.9] 26,700 26,800 [7.9] 26,700 26,700 26,900 [7.9] 25,300 27,200 [8.0] 29,100 29,100 30,300 30,300 9,800 10,300 10,200 10,500 9,800 10,400 10,400 S 1,150 [543] 1,125 [531] 1,150 [543] 1,075 [507] 1,325 [625] 1,325 [625] AHRI Heating Performance (70 F [21 C] ) Air 33,600 33,600 33,000 [9.7] 3.48 Air 2 24,600 [7.2] 25,400 25,400 24, Rely on Ruud. 15

16 AHRI Standard Conditions (cont.) 042JAZ RCFL-H*4821(RGLT-10(E,N)BRMR) RCFL-H*4821(RGLT-10?BRM?) RCFL-H*4821(RGPE-07(E,N)BRQR) RCFL-H*4821(RGPE-10(E,N)BRMR) RCFL-H*4821(RGPT-07(E,N)AMKR) RCFL-H*4821(RGPT-07?AMK?) RCFL-H*4821(RGPT-07(E,N)BRQR) RCFL-H*4821(RGPT-07?BRQ?) RCFL-H*4821(RGPT-10?BRM?) RCFL-H*4821(RGTM-06(E,N)MAES) RCFL-H*4821(RGTM-07(E,N)RBGS) RCFL-H*4821(RGTM-09(E,N)ZAJS) RCFL-H*4821(RHWB-04WMX36A) RCFL-H*4821(RHWB-06WMX48A) RCFL-H*4821(ROLA-070E04) RCFL-H*4821(ROLA-115E05) RCFL-H*4821+RXMD-C04 RCFL-H*4824 RCFL-H*4824(RGFE-09(E,N)ZCMS) RCFL-H*4824(RGFE-12(E,N)RCMS) RCFL-H*4824(RGFG-09EZCMS) RCFL-H*4824(RGFG-10EZCMS) RCFL-H*4824(RGFG-12ERCMS) RCFL-H*4824(RGGE-09(E,N)ZCMS) RCFL-H*4824(RGGE-10(E,N)ZCMS) RCFL-H*4824(RGGE-12(E,N)RCMS) RCFL-H*4824(RGJF-09(E,N)ZCMS) RCFL-H*4824(RGJF-10(E,N)ZCMS) 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 28,800 28,800 30,300 30,300 27,700 [8.1] 29,100 30,300 30,300 10,200 10,200 10,800 10,400 10,400 10,400 S 1,350 [637] 1,350 [637] 1,325 [625] 1,325 [625] 1,325 [625] AHRI Heating Performance (70 F [21 C] ) Air 37,600 Air 25,400 25,400 26,200 24,600 [7.2] 25,400 25,400 25, Rely on Ruud.

17 AHRI Standard Conditions (cont.) 042JAZ RCFL-H*4824(RGJF-12(E,N)RCMS) RCFL-H*4824(RGLE-07(E,N)BRQR) RCFL-H*4824(RGLE-07?BRQ?) RCFL-H*4824(RGLE-10(E,N)BRMR) RCFL-H*4824(RGLE-12(E,N)ARMR) RCFL-H*4824(RGLT-07(E,N)BRQR) RCFL-H*4824(RGLT-07?BRQ?) RCFL-H*4824(RGLT-10(E,N)BRMR) RCFL-H*4824(RGLT-10?BRM?) RCFL-H*4824(RGLT-12(E,N)ARMR) RCFL-H*4824(RGLT-12?ARM?) RCFL-H*4824(RGPE-07(E,N)BRQR) RCFL-H*4824(RGPE-10(E,N)BRMR) RCFL-H*4824(RGPE-12(E,N)ARMR) RCFL-H*4824(RGPT-07(E,N)BRQR) RCFL-H*4824(RGPT-07?BRQ?) RCFL-H*4824(RGPT-10?BRM?) RCFL-H*4824(RGPT-12(E,N)ARMR) RCFL-H*4824(RGPT-12?ARM?) RCFL-H*4824(RGRM-12(E,N)RAJS) RCFL-H*4824(RGTM-07(E,N)RBGS) RCFL-H*4824(RGTM-09(E,N)ZAJS) RCFL-H*4824(RGTM-10(E,N)RBJS) RCFL-H*4824(RHWB-08WRX60A) RCFL-H*4824(RHWB-10WRX60A) RCFL-H*4824(ROLA-070E04) RCFL-H*4824(ROLA-115E05) RCFL-H*4824+RXMD-C04 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 30,300 30,300 29,100 30,300 10,400 10,200 S 1,325 [625] 1,350 [637] AHRI Heating Performance (70 F [21 C] ) Air 37,600 Air 24,800 24,800 24,800 24,800 24,800 24,800 24,800 24,600 [7.2] Rely on Ruud. 17

18 AHRI Standard Conditions (cont.) 042JAZ 043JAZ RHKL-HM4821(RCSL-H*4821) RHLL-HM4821(RCSL-H*4821) RHSL-HM4221(RCSL-H*4821) RHLL-HM4821(RCSL-H*4821) ➀ RCFL-H*4821(RGFE-09(E,N)ZCMS) RCFL-H*4821(RGFE-10(E,N)ZCMS) RCFL-H*4821(RGFG-09EZCMS) RCFL-H*4821(RGFG-10EZCMS) RCFL-H*4821(RGGE-09(E,N)ZCMS) RCFL-H*4821(RGGE-10(E,N)ZCMS) RCFL-H*4821(RGJF-09(E,N)ZCMS) RCFL-H*4821(RGJF-10(E,N)ZCMS) RCFL-H*4821(RGLE-07(E,N)BRQR) RCFL-H*4821(RGLE-07?BRQ?) RCFL-H*4821(RGLE-10(E,N)BRMR) RCFL-H*4821(RGLT-07(E,N)AMKR) RCFL-H*4821(RGLT-07?AMK?) RCFL-H*4821(RGLT-07(E,N)BRQR) RCFL-H*4821(RGLT-07?BRQ?) RCFL-H*4821(RGLT-10(E,N)BRMR) RCFL-H*4821(RGLT-10?BRM?) RCFL-H*4821(RGPE-07(E,N)BRQR) RCFL-H*4821(RGPE-10(E,N)BRMR) RCFL-H*4821(RGPT-07(E,N)AMKR) RCFL-H*4821(RGPT-07?AMK?) RCFL-H*4821(RGPT-07(E,N)BRQR) RCFL-H*4821(RGPT-07?BRQ?) RCFL-H*4821(RGPT-10?BRM?) F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 2 29,300 29,300 30,500 30,500 30,400 30,400 30,500 30,500 30,400 10,600 1 [3.3] 1 [3.3] 10,500 10,500 10,600 10,600 10,500 10,500 10,600 S ,325 [625] 1,325 [625] 1,350 [637] 1,350 [637] AHRI Heating Performance (70 F [21 C] ) Air Air 24,800 24,800 25,600 [7.5] 24,600 [7.2] 24,600 [7.2] 24,600 [7.2] 24,600 [7.2] Rely on Ruud.

19 AHRI Standard Conditions (cont.) 043JAZ RCFL-H*4821(RGTM-07(E,N)RBGS) RCFL-H*4821(RGTM-09(E,N)ZAJS) RCFL-H*4821(RHWB-04WMX36A) RCFL-H*4821(RHWB-06WMX48A) RCFL-H*4821(ROLA-070E04) RCFL-H*4821(ROLA-115E05) RCFL-H*4821+RXMD-C04 RCFL-H*4824(RGFE-09(E,N)ZCMS) RCFL-H*4824(RGFE-10(E,N)ZCMS) RCFL-H*4824(RGFE-12(E,N)RCMS) RCFL-H*4824(RGFG-09EZCMS) RCFL-H*4824(RGFG-10EZCMS) RCFL-H*4824(RGFG-12ERCMS) RCFL-H*4824(RGGE-09(E,N)ZCMS) RCFL-H*4824(RGGE-10(E,N)ZCMS) RCFL-H*4824(RGGE-12(E,N)RCMS) RCFL-H*4824(RGJF-09(E,N)ZCMS) RCFL-H*4824(RGJF-10(E,N)ZCMS) RCFL-H*4824(RGJF-12(E,N)RCMS) RCFL-H*4824(RGLE-07(E,N)BRQR) RCFL-H*4824(RGLE-07?BRQ?) RCFL-H*4824(RGLE-10(E,N)BRMR) RCFL-H*4824(RGLE-12(E,N)ARMR) RCFL-H*4824(RGLT-07(E,N)BRQR) RCFL-H*4824(RGLT-07?BRQ?) RCFL-H*4824(RGLT-10(E,N)BRMR) RCFL-H*4824(RGLT-10?BRM?) RCFL-H*4824(RGLT-12(E,N)ARMR) F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 29,300 29,300 29, ,500 30,500 30,400 30,500 30,500 30,400 30,400 1 [3.3] 1 [3.3] 1 [3.3] 10,600 10,500 10,500 10,600 10,500 10,500 10,600 10,600 S 1,325 [625] 1,325 [625] 1,325 [625] AHRI Heating Performance (70 F [21 C] ) Air , Air 23,000 [6.7] 24,600 [7.2] 24,600 [7.2] 24,600 [7.2] 24,600 [7.2] Rely on Ruud. 19

20 AHRI Standard Conditions (cont.) 043JAZ 048JAZ RCFL-H*4824(RGLT-12?ARM?) RCFL-H*4824(RGPE-07(E,N)BRQR) RCFL-H*4824(RGPE-10(E,N)BRMR) RCFL-H*4824(RGPE-12(E,N)ARMR) RCFL-H*4824(RGPT-07(E,N)BRQR) RCFL-H*4824(RGPT-07?BRQ?) RCFL-H*4824(RGPT-10?BRM?) RCFL-H*4824(RGPT-12(E,N)ARMR) RCFL-H*4824(RGPT-12?ARM?) RCFL-H*4824(RGRM-12(E,N)RAJS) RCFL-H*4824(RGTM-07(E,N)RBGS) RCFL-H*4824(RGTM-09(E,N)ZAJS) RCFL-H*4824(RGTM-10(E,N)RBJS) RCFL-H*4824(RHWB-08WRX60A) RCFL-H*4824(RHWB-10WRX60A) RCFL-H*4824(ROLA-070E04) RCFL-H*4824(ROLA-115E05) RCFL-H*4824+RXMD-C04 RHKL-HM4821(RCSL-H*4821) RHSL-HM4221(RCSL-H*4821) RHLL-HM4821(RCSL-H*4821) ➀ RCFL-H*4821 RCFL-H*4821(RGFE-09(E,N)ZCMS) RCFL-H*4821(RGFE-10(E,N)ZCMS) RCFL-H*4821(RGFG-09EZCMS) RCFL-H*4821(RGFG-10EZCMS) RCFL-H*4821(RGGE-09(E,N)ZCMS) RCFL-H*4821(RGGE-10(E,N)ZCMS) ,500 [13.3] 44,000 [12.9] 44,000 [12.9] 44,000 [12.9] 44,000 [12.9] 44,000 [12.9] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 30,400 30,500 30,500 30,400 30,400 29,300 30,400 34,900 [10.2] 33,200 [9.7] 32,200 [9.4] 32,400 [9.5] 32,200 [9.4] 32,200 [9.4] 33,000 [9.7] 32,200 [9.4] 10,600 10,500 10,500 10,600 10,600 1 [3.3] 10,600 10,600 11,300 [3.3] 11,600 11,500 S ,325 [625] 1,350 [637] 1,600 [755] 1,475 [696] AHRI Heating Performance (70 F [21 C] ) Air , ,500 [13.3] Air 23,000 [6.7] 24,800 27,400 [8.0] Rely on Ruud.

21 AHRI Standard Conditions (cont.) 048JAZ RCFL-H*4821(RGJF-09(E,N)ZCMS) RCFL-H*4821(RGJF-10(E,N)ZCMS) RCFL-H*4821(RGLE-07(E,N)BRQR) RCFL-H*4821(RGLE-07?BRQ?) RCFL-H*4821(RGLE-10(E,N)BRMR) RCFL-H*4821(RGLT-07(E,N)AMKR) RCFL-H*4821(RGLT-07?AMK?) RCFL-H*4821(RGLT-07(E,N)BRQR) RCFL-H*4821(RGLT-07?BRQ?) RCFL-H*4821(RGLT-10(E,N)BRMR) RCFL-H*4821(RGLT-10?BRM?) RCFL-H*4821(RGPE-07(E,N)BRQR) RCFL-H*4821(RGPE-10(E,N)BRMR) RCFL-H*4821(RGPT-07(E,N)BRQR) RCFL-H*4821(RGPT-07?BRQ?) RCFL-H*4821(RGPT-10?BRM?) RCFL-H*4821(RGRM-09(E,N)ZAJS) RCFL-H*4821(RGRM-10(E,N)ZAJS) RCFL-H*4821(RGTM-07(E,N)RBGS) RCFL-H*4821(RGTM-09(E,N)ZAJS) RCFL-H*4821(ROCA-070E04) RCFL-H*4821(ROLA-070E04) RCFL-H*4821(ROLA-115E05) RCFL-H*4824 RCFL-H*4824(RGFE-09(E,N)ZCMS) RCFL-H*4824(RGFE-10(E,N)ZCMS) RCFL-H*4824(RGFE-12(E,N)RCMS) RCFL-H*4824(RGFG-09EZCMS) 44,000 [12.9] 45,500 [13.3] 44,000 [12.9] 44,000 [12.9] 44,000 [12.9] 44,000 [12.9] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 33,000 [9.7] 32,200 [9.4] 33,500 32,900 32,900 32,800 32,800 32,800 32,800 33,300 32,200 [9.4] 33,200 [9.7] 33,000 [9.7] 33,000 [9.7] 32,500 [9.5] 32,900 32,800 33,200 [9.7] 32,200 [9.4] 32,200 [9.4] 33,000 [9.7] 32,200 [9.4] 11,500 12,000 11,600 11, ,500 11,500 12,000 12, ,300 [3.3] 11,500 S ,475 [696] 1,475 [696] AHRI Heating Performance (70 F [21 C] ) Air 45,500 [13.3] 45,500 [13.3] 45,500 [13.3] Air 29,000 29,000 28,800 28,800 27,400 [8.0] Rely on Ruud. 21

22 AHRI Standard Conditions (cont.) 048JAZ RCFL-H*4824(RGFG-10EZCMS) RCFL-H*4824(RGFG-12ERCMS) RCFL-H*4824(RGGE-09(E,N)ZCMS) RCFL-H*4824(RGGE-10(E,N)ZCMS) RCFL-H*4824(RGGE-12(E,N)RCMS) RCFL-H*4824(RGJF-09(E,N)ZCMS) RCFL-H*4824(RGJF-10(E,N)ZCMS) RCFL-H*4824(RGJF-12(E,N)RCMS) RCFL-H*4824(RGLE-07(E,N)BRQR) RCFL-H*4824(RGLE-07?BRQ?) RCFL-H*4824(RGLE-10(E,N)BRMR) RCFL-H*4824(RGLE-12(E,N)ARMR) RCFL-H*4824(RGLT-07(E,N)BRQR) RCFL-H*4824(RGLT-07?BRQ?) RCFL-H*4824(RGLT-10(E,N)BRMR) RCFL-H*4824(RGLT-10?BRM?) RCFL-H*4824(RGPE-07(E,N)BRQR) RCFL-H*4824(RGPE-10(E,N)BRMR) RCFL-H*4824(RGPE-12(E,N)ARMR) RCFL-H*4824(RGPT-07(E,N)BRQR) RCFL-H*4824(RGPT-07?BRQ?) RCFL-H*4824(RGPT-10?BRM?) RCFL-H*4824(RGRM-09(E,N)ZAJS) RCFL-H*4824(RGRM-10(E,N)ZAJS) RCFL-H*4824(RGRM-12(E,N)RAJS) RCFL-H*4824(RGTM-07(E,N)RBGS) RCFL-H*4824(RGTM-09(E,N)ZAJS) RCFL-H*4824(RGTM-10(E,N)RBJS) 44,000 [12.9] 44,000 [12.9] 44,000 [12.9] 45,500 [13.3] 44,000 [12.9] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 32,200 [9.4] 33,000 [9.7] 32,200 [9.4] 32,500 [9.5] 32,500 [9.5] 32,300 [9.5] 33,500 33,200 [9.7] 32,800 32,800 33,200 [9.7] 32,800 32,800 32,200 [9.4] 33,000 [9.7] 33,000 [9.7] 11,500 12,000 12, , ,000 11,500 S ,475 [696] AHRI Heating Performance (70 F [21 C] ) Air 45,500 [13.3] 45,500 [13.3] 45,500 [13.3] Air 29,000 29,000 28, Rely on Ruud.

23 AHRI Standard Conditions (cont.) 048JAZ 049JAZ RCFL-H*4824(RHWB-08WRX60A) RCFL-H*4824(RHWB-10WRX60A) RCFL-H*4824(ROCA-070E04) RCFL-H*4824(ROLA-070E04) RCFL-H*4824(ROLA-115E05) RHKL-HM4821(RCSL-H*4821) RHSL-HM4821(RCSL-H*4821) RHKL-HM4824(RCSL-H*4824) RHLL-HM4824(RCSL-H*4824) RHSL-HM4824(RCSL-H*4824) RHLL-HM6024(RCSL-H*6024) ➀ RCFL-H*6024(RGFE-09(E,N)ZCMS) RCFL-H*6024(RGFE-10(E,N)ZCMS) RCFL-H*6024(RGFE-12(E,N)RCMS) RCFL-H*6024(RGFG-09EZCMS) RCFL-H*6024(RGFG-10EZCMS) RCFL-H*6024(RGFG-12ERCMS) RCFL-H*6024(RGGE-09(E,N)ZCMS) RCFL-H*6024(RGGE-10(E,N)ZCMS) RCFL-H*6024(RGGE-12(E,N)RCMS) RCFL-H*6024(RGJF-09(E,N)ZCMS) RCFL-H*6024(RGJF-10(E,N)ZCMS) RCFL-H*6024(RGJF-12(E,N)RCMS) RCFL-H*6024(RGLE-07(E,N)BRQR) RCFL-H*6024(RGLE-07?BRQ?) RCFL-H*6024(RGLE-10(E,N)BRMR) RCFL-H*6024(RGLE-12(E,N)ARMR) RCFL-H*6024(RGLT-07(E,N)BRQR) 45,500 [13.3] 45,500 [13.3] 46,000 [13.5] 46,000 [13.5] 45,500 [13.3] 48,500 [14.2] 46,500 [13.6] 4 [14.1] 4 [14.1] 47,500 [13.9] 47,500 [13.9] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 32,500 [9.5] 32,500 [9.5] 33,100 [9.7] 34,500 36,700 33,900 [9.9] 33,900 [9.9] 33,400 33,900 [9.9] 33,900 [9.9] 36,200 [10.6] 33,900 [9.9] 33,900 [9.9] 36,200 [10.6] 33,900 [9.9] 33,900 [9.9] 33,900 [9.9] 34,500 34,700 [10.2] 11,500 11,500 12,000 12,000 11, ,200 10, ,000 12,800 12,800 13,000 12,800 S 1,475 [696] 1,550 [731] 1,625 [767] 1,625 [767] 1,550 [731] 1,600 [755] 1,575 [743] 1,575 [743] AHRI Heating Performance (70 F [21 C] ) Air 45,500 [13.3] 45,500 [13.3] 45,500 [13.3] 44,000 [12.9] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] Air 28,800 28, ,000 29,000 26,600 26,200 26,400 26,000 26,200 26,200 26,000 26,000 26,200 26,200 26,000 26,200 26,200 26,000 26,000 25,800 25,800 26, Rely on Ruud. 23

24 AHRI Standard Conditions (cont.) 049JAZ RCFL-H*6024(RGLT-07?BRQ?) RCFL-H*6024(RGLT-10(E,N)BRMR) RCFL-H*6024(RGLT-10?BRM?) RCFL-H*6024(RGLT-12(E,N)ARMR) RCFL-H*6024(RGLT-12?ARM?) RCFL-H*6024(RGPE-07(E,N)BRQR) RCFL-H*6024(RGPE-10(E,N)BRMR) RCFL-H*6024(RGPE-12(E,N)ARMR) RCFL-H*6024(RGPT-07(E,N)BRQR) RCFL-H*6024(RGPT-07?BRQ?) RCFL-H*6024(RGPT-10?BRM?) RCFL-H*6024(RGPT-12(E,N)ARMR) RCFL-H*6024(RGPT-12?ARM?) RCFL-H*6024(RGRM-07(E,N)YBGS) RCFL-H*6024(RGRM-09(E,N)ZAJS) RCFL-H*6024(RGRM-10(E,N)ZAJS) RCFL-H*6024(RGRM-12(E,N)RAJS) RCFL-H*6024(RGTM-07(E,N)RBGS) RCFL-H*6024(RGTM-09(E,N)ZAJS) RCFL-H*6024(RGTM-10(E,N)RBJS) RCFL-H*6024(RHWB-08WRX60A) RCFL-H*6024(RHWB-10WRX60A) RCFL-H*6024(ROCA-070E04) RCFL-H*6024(ROLA-070E04) RCFL-H*6024(ROLA-115E05) RCFL-H*6024+RXMD-C04 RHKL-HM6024(RCSL-H*6024) 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 47,500 [13.9] 46,000 [13.5] 46,500 [13.6] 46,500 [13.6] 47,500 [13.9] 47,500 [13.9] 46,500 [13.6] 47,500 [13.9] 48,500 [14.2] 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air 34,700 [10.2] 34,700 [10.2] 34,700 [10.2] 33,900 [9.9] 35,400 34,500 34,700 [10.2] 34,700 [10.2] 34,700 [10.2] 33,700 [9.9] 33,700 [9.9] 32,900 33,400 33,500 33,900 [9.9] 34,700 [10.2] 35,000 [10.3] 33,400 33,700 [9.9] 33,900 [9.9] 35,700 36,700 12,800 12,800 12,800 12,100 13,000 12,800 12,800 12,800 13,300 13,300 13,000 13,000 12,600 [3.7] 13,000 12,800 12,500 [3.7] 13,300 S ,550 [731] 1,475 [696] 1,500 [708] 1,600 [755] 1,600 [755] AHRI Heating Performance (70 F [21 C] ) Air 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 43,000 [12.6] 44,000 [12.9] 43,000 [12.6] 43,000 [12.6] 42,000 [12.3] 43,000 [12.6] Air 26,000 26,000 26,000 25,800 25,800 25,800 26,200 25,800 26,000 26,000 25,800 25,600 [7.5] 25,600 [7.5] 27,200 [8.0] 26,400 26,400 26,200 26,200 26,000 26,000 25,800 25,800 26,400 26,000 26,000 24,600 [7.2] 25,600 [7.5] Rely on Ruud.

25 AHRI Standard Conditions (cont.) 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air S AHRI Heating Performance (70 F [21 C] ) Air Air RHLL-HM6024(RCSL-H*6024) ➀ RCFL-H*6024(RGFD-12?RCM?) 52,500 [15.4] 52,000 [15.2] 37,900 37,950 14,600 [4.3] 14,050 [4.1] 1,600 [755] 1,650 [779] 5 [14.9] 51,500 [15.1] RCFL-H*6024(RGGE-12(E,N)RCMS) 52,000 [15.2] 37,400 14,600 [4.3] 1,575 [743] 50,500 [14.8] 28, RCFL-H*6024(RGJF-12(E,N)RCMS) 52,000 [15.2] 37,400 14,600 [4.3] 1,575 [743] 50,500 [14.8] 28, RCFL-H*6024(RGLE-07(E,N)BRQR) 52,000 [15.2] 37,400 14,600 [4.3] 1,600 [755] 50,500 [14.8] 28, RCFL-H*6024(RGLE-07?BRQ?) 52,000 [15.2] 37,400 14,600 [4.3] 1,600 [755] 50,500 [14.8] 28, RCFL-H*6024(RGLE-10(E,N)BRMR) 52,000 [15.2] 37,400 14,600 [4.3] 1,600 [755] 50,500 [14.8] RCFL-H*6024(RGLE-12(E,N)ARMR) 52,000 [15.2] 37,400 14,600 [4.3] 1,600 [755] 50,500 [14.8] RCFL-H*6024(RGLT-10(E,N)BRMR) 52,000 [15.2] 3 [11.2] 13,800 5 [14.9] , RCFL-H*6024(RGLT-10?BRM?) 52,000 [15.2] 3 [11.2] 13,800 5 [14.9] , RCFL-H*6024(RGLT-12(E,N)ARMR) 52,500 [15.4] 38,700 13,800 5 [14.9] 28, RCFL-H*6024(RGLT-12?ARM?) 52,500 [15.4] 38,700 13,800 5 [14.9] 28, RCFL-H*6024(RGPE-07(E,N)BRQR) 52,000 [15.2] 37,400 14,600 [4.3] 1,600 [755] 50,500 [14.8] 28, RCFL-H*6024(RGPE-10(E,N)BRMR) 51,500 [15.1] 14,900 [4.4] 1,550 [731] 50,500 [14.8] JAZ RCFL-H*6024(RGPE-12(E,N)ARMR) 51,500 [15.1] 15,100 [4.4] 1,525 [720] 50,500 [14.8] RCFL-H*6024(RGPT-07(E,N)BRQR) 52,000 [15.2] 3 [11.2] 13,800 5 [14.9] , RCFL-H*6024(RGPT-07?BRQ?) 52,000 [15.2] 3 [11.2] 13,800 5 [14.9] , RCFL-H*6024(RGPT-10?BRM?) 52,000 [15.2] 38,350 [11.2] 13,650 51,500 [15.1] RCFL-H*6024(RGPT-12(E,N)ARMR) 52,500 [15.4] 38,700 13,800 5 [14.9] 29, RCFL-H*6024(RGPT-12?ARM?) 52,500 [15.4] 38,700 13,800 5 [14.9] 29, RCFL-H*6024(RGRM-12(E,N)RAJS) 51,500 [15.1] 14,900 [4.4] 1,550 [731] 5 [14.9] 29, RCFL-H*6024(RGTM-07(E,N)RBGS) 5 [14.9] 35,700 15,300 [4.5] ,475 [696] 51,500 [15.1] RCFL-H*6024(RGTM-09(E,N)ZAJS) 51,500 [15.1] 14,900 [4.4] 1,550 [731] 5 [14.9] 28, RCFL-H*6024(RGTM-10(E,N)RBJS) 51,500 [15.1] 36,900 14,600 [4.3] 1,625 [767] 5 [14.9] 29, RCFL-H*6024(RHWB-08WRX60A) 52,000 [15.2] 37,800 14,200 [4.2] 1,650 [779] 50,500 [14.8] 28, RCFL-H*6024(RHWB-10WRX60A) 52,500 [15.4] 38,700 13,800 50,500 [14.8] RCFL-H*6024(ROLA-115E05) 51,500 [15.1] 37,100 [10.9] 14,400 [4.2] 1,600 [755] 51,500 [15.1] RCFL-H*6024+RXMD-C04 51,500 [15.1] 36,900 14,600 [4.3] 1,600 [755] 49,000 [14.4] 27,200 [8.0] RHKL-HM6024(RCSL-H*6024) 52,500 [15.4] 37,900 14,600 [4.3] ,600 [755] 50,000 [14.6] 2 [8.2] Rely on Ruud. 25

26 AHRI Standard Conditions (cont.) 80 F [26.5 C] DB/67 F [19.5 C] WB Air 95 F [35 C] DB Air S AHRI Heating Performance (70 F [21 C] ) Air Air RHLL-HM6024(RCSL-H*6024) ➀ RCFL-H* ,500 [17.4] 5 [17.0] 42,250 [12.4] 3 17,250 18, ,800 [849] 1,675 [790] 59,500 [17.4] 5 [17.0] 37, RCFL-H*6024(RGLT-07(E,N)BRQR) 18,500 37, RCFL-H*6024(RGLT-07?BRQ?) 18,500 37, RCFL-H*6024(RGLT-10(E,N)BRMR) 18,500 37, RCFL-H*6024(RGLT-10?BRM?) 18,500 37, RCFL-H*6024(RGLT-12(E,N)ARMR) 18,500 37, JAZ RCFL-H*6024(RGLT-12?ARM?) RCFL-H*6024(RGPT-07(E,N)BRQR) 18,500 18,500 37,400 37, RCFL-H*6024(RGPT-07?BRQ?) 18,500 37, RCFL-H*6024(RGPT-10?BRM?) 18,500 37, RCFL-H*6024(RGPT-12(E,N)ARMR) 18,500 37, RCFL-H*6024(RGPT-12?ARM?) 18,500 37, RCFL-H*6024(RHWB-10WRX60A) 59,500 [17.4] 4 18,500 59,500 [17.4] 37,200 [10.9] RHKL-HM6024(RCSL-H*6024) 59,500 [17.4] 42,250 [12.4] 17,250 1,800 [849] 59,500 [17.4] 37, RHSL-HM6024(RCSL-H*6024) 58,500 [17.1] 41,500 [12.2] 17,000 [5.0] ,800 [849] 58,500 [17.1] Rely on Ruud.

27 Electrical and Physical Data Electrical and Physical Data ELECTRICAL PHYSICAL Model Compressor Fan Motor Minimum Fuse or HACR Number Phase Coil Refrig. Weight Full Load Circuit Frequency (Hz) d Load Locked Rotor Circuit Breaker Per Amperes Ampacity Circuit Voltage (Volts) Amperes Amperes Minimum Maximum Face Area No. (RLA) (LRA) (FLA) Amperes Amperes Amperes Sq. Ft. [m 2 ] Rows Shipping Oz. [g] Lbs. [kg] Lbs. [kg] 1/7/13 018JAZ /230 9/ /13 15/15 20/20 11 [1.02] [908] 85 [2410] 156 [70.8] [70.8] 024JAZ / / /19 25/25 30/30 13 [1.21] [908] 98 [2778] 156 [70.8] 176 [70.8] 030JAZ / / /20 25/25 30/ [1.59] [908] 120 [3402] 175 [79.4] [79.4] 036JAZ / / /24 30/30 40/ [1.59] [1687] 194 [5500] 226 [102.5] [102.5] 037JAZ /230 17/ /22 30/30 35/35 23 [2.14] [1652] 144 [4082] 246 [111.6] 256 [111.6] 042JAZ / / /24 30/30 40/40 23 [2.14] [1687] 208 [5897] 256 [116.1] 261 [116.1] 043JAZ / / /24 30/30 40/40 23 [2.14] [1687] 208 [5897] 256 [116.1] 261 [116.1] 048JAZ / / /27 35/35 45/45 23 [2.14] [1687] 231 [6549] 258 [117] 296 [117] 049JAZ / / /27 35/35 45/45 23 [2.14] [1687] 231 [6549] 258 [117] 296 [117] 056JAZ / / /30 35/35 50/50 23 [2.14] [1463] 274 [7768] 300 [136.1] 304 [136.1] 060JAZ / / /36 45/45 60/60 23 [2.14] [1463] 277 [7853] 300 [136.1] 304 [136.1] NOTE: Factory Refrigerant Charge includes refrigerant for 15 feet of standard line set. Rely on Ruud. 27

28 Dimensions Dimensions Model Number Height H (Inches) [mm] Length L (Inches) [mm] Width W (Inches) [mm] 018JAZ 19 [482] 40 1 / 2 [1028] 27 5 / 8 [701] 024JAZ 19 [482] 44 3 / 8 [1127] 31 1 / 2 [800] 030JAZ/036JAZ/037JAZ/042JAZ/043JAZ 33 [838] 44 3 / 8 [1127] 31 1 / 2 [800] 048JAZ/049JAZ/056JAZ/060JAZ 33 [838] 44 3 / 8 [1127] 31 1 / 2 [800] AIR DISCHARGE ALLOW 60 [1524 mm] CLEARANCE LOW VOLTAGE CONNECTION 7/80 [22 mm] W L SERVICE FITTINGS H ACCESS PANEL HIGH VOLTAGE CONNECTION 1 11 /320 [34 mm] AIR INLETS (LOUVERS) ALLOW 6 [152 mm] MIN. CLEARANCE 3 SIDES A ALLOW 24 [610 mm] ACCESS CLEARANCE A HIGH PRESSURE CONTROL MANUAL RESET (FIELD INSTALLED ACCESSORY) VAPOR LINE CONNECTION 2 7 /80 [73 mm] DIA. ACCESSORY KNOCKOUTS LIQUID LINE CONNECTION SERVICE ACCESS TO ELECTRICAL & VALVES ALLOW 240 [610 mm] CLEARANCE ONE SIDE 28 Rely on Ruud.

29 Refrigerant Line Size Information Heat Pump Refrigerant Line Size Information System 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Line Size Connection Size (Inch I.D.) [mm] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] 3/8" [9.53] NOTES: *Standard line size N/A = Application not recommended. Line Size (Inch O.D.) [mm] 1/4 [6.35] 5/16 [7.94] 3/8* [9.53] 1/4 [6.35] 5/16 [7.94] 3/8* [9.53] 1/4 [6.35] 5/16 [7.94] 3/8* [9.53] 5/16 [7.94] 3/8* [9.53] 5/16 [7.94] 3/8* [9.53] 3/8* [9.53] 1/2 3/8* [9.53] 1/2 Liquid Line Sizing (R-410A) Above or Below Coil (Heat Pumps Only) Equivalent LengthFeet [m] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.10] 150 [45.72] Maximum Vertical SeparationFeet [m] 25 [7.62] 40 [12.19] 25 [7.62] 9 [2.74] N/A N/A 25 [7.62] 50 [15.24] 62 [18.90] 58 [17.68] 53 [16.15] 49 [14.94] 25 [7.62] 50 [15.24] 75 [22.86] 72 [21.95] 70 [21.34] 68 [20.73] 23 [7.01] N/A N/A N/A N/A N/A 25 [7.62] 36 [10.97] 29 [8.84] 23 [7.01] 16 [4.88] 9 [2.74] 25 [7.62] 50 [15.24] 72 [21.95] 70 [21.34] 68 [20.73] 65 [19.81] 25 [7.62] N/A N/A N/A N/A N/A 25 [7.62] 49 [14.94] 38 [11.58] 27 [8.23] 17 [5.18] 6 [1.83] 25 [7.62] 50 [15.24] 68 [20.73] 65 [19.81] 62 [18.90] 58 [17.68] 25 [7.62] 50 [15.24] 37 [11.28] 22 [6.71] 7 [2.13] N/A 25 [7.62] 50 [15.24] 68 [20.73] 63 [19.20] 58 [17.68] 53 [16.15] 25 [7.62] 23 [7.01] 4 [1.22] N/A N/A N/A 25 [7.62] 50 [15.24] 43 [13.11] 36 [10.97] 30 [9.14] 24 [7.32] 25 [7.62] 46 [14.02] 38 [11.58] 30 [9.14] 22 [6.71] 15 [4.57] 25 [7.62] 50 [15.24] 56 [17.07] 55 [16.76] 53 [16.15] 52 [15.85] 25 [7.62] 50 [15.24] 56 [17.07] 44 [13.41] 32 [9.75] 20 [6.10] 25 [7.62] 50 [15.24] 75 [22.86] 81 [24.69] 79 [24.08] 76 [23.16] Suction Line Length/Size versus Multiplier (R-410A) Size 1 1 /2 Ton 2 Ton 2 1 /2 Ton 3 Ton 3 1 /2 Ton 4 Ton 5 Ton Suction Line 3/4" [19.05] I.D. 7/8" [22.23] I.D. Connection Size Suction Line Run Feet [m] 25' [7.62] 50' [15.24] 100' [30.48] 150' [45.72] Optional Standard Optional Optional Standard Optional Optional Standard Optional Optional Standard Optional 5/8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* /8" [15.88 mm] O.D. Opt. 3/4" [19.05 mm] O.D. Std.* 7/8" [22.23 mm] O.D. Opt NOTES: *Standard line size N/A = Using suction line larger than shown in chart will result in poor oil return and is not recommended. 3/4" [19.05 mm] O.D. Opt. 7/8" [22.23 mm] O.D. Std.* /8" [22.23 mm] O.D. Opt. 1 1 /8" [28.58 mm] O.D. Std.* Rely on Ruud. 29

30 Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts (Registration Required)...Ten (10) Years 30 Rely on Ruud.

31 Notes Rely on Ruud. 31

32 In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Rely on Ruud. Ruud Heating, Cooling & Water Heating P.O. Box Fort Smith, Arkansas Ruud Canada 125 Edgeware Road, 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A 01/13 QG FORM NO. P REV. 1

Rheem Prestige Series Heat Pumps equipped with the Comfort Control System

Rheem Prestige Series Heat Pumps equipped with the Comfort Control System 15.5 Air Heat Pumps Rheem Prestige Series Heat Pumps equipped with the Comfort Control System Efficiencies up to 15.5 /13.0 /9.5 Nominal Sizes 1.5 to 5 Ton [5.28 to 17.6 kw] Proper sizing and installation

More information

Ruud Achiever Series Heat Pumps

Ruud Achiever Series Heat Pumps 16.0 Heat Pumps Series Ruud Achiever Series Heat Pumps Series Efficiencies up to 14.50 SEER/12.00 EER/9.50 HSPF Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Proper sizing and installation of equipment is

More information

HEAT PUMPS UPKB- SERIES. Seven Models

HEAT PUMPS UPKB- SERIES. Seven Models FORM NO. P22-754 REV. 1 Supersedes Form No. P11-729 Rev. 8 HEAT PUMPS UPKB- SERIES Seven Models 10 SEER with efficiencies ranging up to 10.30 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5

More information

CONDENSING UNITS UAPC- SERIES. Six Models. Cooling Capacities 23,200 to 56,500 BTU/HR [6.8 kw] to [16.6 kw]

CONDENSING UNITS UAPC- SERIES. Six Models. Cooling Capacities 23,200 to 56,500 BTU/HR [6.8 kw] to [16.6 kw] FORM NO. A22-173 REV. 9 Supersedes Form No. A22-173 Rev. 8 CONDENSING UNITS SERIES 14 SEER Models With efficiencies up to 16 SEER in certain matched systems. Nominal Sizes 2 to 5 Tons [7.03 kw] to [17.58

More information

13 SEER CONDENSING UNITS

13 SEER CONDENSING UNITS FORM NO. ATZ-218 REV. 1 Supersedes Form No. ATZ-205 Featuring Industry Standard R-410A Refrigerant 13 SEER CONDENSING UNITS Features Painted louvered steel cabinet. Easily accessible control box. Condenser

More information

HEAT PUMPS UPLB- SERIES. Seven Models

HEAT PUMPS UPLB- SERIES. Seven Models FORM NO. P22-755 Supersedes Form No. P11-732 Rev. 6 HEAT PUMPS UPLB- SERIES Seven Models 11 SEER with efficiencies ranging up to 12 SEER in certain matched systems. Nominal Sizes 1 1 /2 to 5 Tons [5.28

More information

Rheem Value Series Two-Stage Air Conditioners

Rheem Value Series Two-Stage Air Conditioners 16.0 Air Air Conditioners Rheem Value Series Two- Air Conditioners Series Efficiencies up to 16 SEER/13 EER Nominal Sizes 2-5 Ton [7.03 to 17.6 kw] Cooling Capacities 25,400 to 57,000 BTU/H [7.44 to 16.70

More information

CONDENSING UNITS RAKB- SERIES. Seven Models

CONDENSING UNITS RAKB- SERIES. Seven Models FORM NO. A11-168 REV. 2 Supersedes Form No. A11-168 Rev. 1 Supersedes Form No. A11-147 Rev. 8 CONDENSING UNITS SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.58 kw] Seven Models 10 SEER with efficiencies

More information

15 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant 15PJL SERIES

15 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant 15PJL SERIES FORM NO. P11-789 REV. 1 Supersedes Form No. P11-789 Featuring New Industry Standard R-410A Refrigerant SERIES (IN CERTAIN MATCHED SYSTEMS) Visit www.rheem.com for complete details. 15 S HEAT PUMPS Features

More information

14.5 SEER VALUE SERIES CONDENSING UNITS

14.5 SEER VALUE SERIES CONDENSING UNITS FORM NO. ATZ-215 Supersedes Form No. ATZ-201 Rev. 1 14.5 SEER VALUE SERIES CONDENSING UNITS Features Painted louvered steel cabinet Easily accessible control box Condenser coils constructed with copper

More information

Rheem Prestige Series Heat Pumps Equipped with The Comfort Control 2. System

Rheem Prestige Series Heat Pumps Equipped with The Comfort Control 2. System 16.0 Air Heat Pumps Rheem Prestige Series Heat Pumps Equipped with The Comfort Control 2 System Series Efficiencies Ranging to 17 SEER/13 EER/9.5 Nominal Sizes 2 to 5 Ton [7.03 to 17.6 kw] Proper sizing

More information

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum FORM NO. PTZ-803 Supersedes Form No. PTZ-781 Featuring Industry Standard R-410A Refrigerant TZPL SERIES Efficiencies up to 14.5 SEER/12.00 EER/8.50 HSPF Nominal Sizes 1.5 to 5 Tons [5.28 kw] to [17.6 kw]

More information

CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models

CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models FORM NO. A22-149 REV. 6 Supersedes Form No. A22-149 Rev. 5 CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 kw] to [17.58 kw] Seven Models

More information

HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]

HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw] FORM NO. P11-729 REV. 6 Supersedes Form No. P11-729 Rev. 5 HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 to 17.58 kw] The Rheem RPKA- Heat Pump Outdoor units can provide

More information

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16. FORM NO. A11-147 REV. 9 Supersedes Form No. A11-147 Rev. 8 CONDENSING UNITS CLASSIC X CONDENSING UNITS Seven Models Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.56 kw] SERIES Nominal Sizes

More information

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum FORM NO. P66-774 Supersedes Form No. P66-765 Rev. 4 Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES earth friendly refrigerant 13 SEER HEAT PUMPS Features Coils constructed with copper tubing

More information

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant TZPL SERIES FORM NO. PTZ-781 Supersedes Form No. PTZ-781 Featuring New Industry Standard R-410A Refrigerant TZPL SERIES Manufactured for Thermal Zone Philadelphia, PA (IN CERTAIN MATCHED SYSTEMS) 14.5 SEER HEAT PUMPS

More information

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum FORM NO. P22-5 REV. 7 Supersedes Form No. P22-5 Rev. 6 13PJA SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinetlouvered design

More information

AIR CONDITIONERS WA14**A SERIES

AIR CONDITIONERS WA14**A SERIES FORM NO. A66-220 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial

More information

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum FORM NO. P11-5 REV. 6 Supersedes Form No. P11-5 Rev. 5 13PJA SERIES 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum fins. Strong, attractive cabinetlouvered design

More information

HEAT PUMPS. Equipped with the Award Winning Comfort Control System RPRL- JEZ. Two-Stage Four Models

HEAT PUMPS. Equipped with the Award Winning Comfort Control System RPRL- JEZ. Two-Stage Four Models FORM NO. P-770 REV. 5 Supersedes Form No. P-770 4 HEAT PUMPS Equipped with the Award Winning Comfort Control System Increased Reliability On-Board Diagnostics Fault Recall Active Protection JEZ Two- Four

More information

AIR CONDITIONERS WA16 SERIES

AIR CONDITIONERS WA16 SERIES FORM NO. A66-222 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light commercial

More information

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity

VS6BF Series 2-4 Ton Capacity. VS4BF Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 5 Ton Capacity TECHNICAL SPECIFICATIONS VS6BF Series 2-4 Ton Capacity VS4BF Series 5 Ton Capacity The VS(4,6)BF Series now offers the choice of an air conditioner that uses a more efficient and environmentally friendly

More information

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.

DS4BD-KB Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner 13 SEER Residential System 1. TECHNICAL SPECIFICATIONS DS4BD-KB Series R-410A High Efficiency Air Conditioner 13 SEER Residential System 1.5 5 Ton Capacity The DS4BD-KB Series now offers the choice of an air conditioner that uses a

More information

Ruud High Efficiency Air Handler

Ruud High Efficiency Air Handler Air Handlers Ruud High Efficiency Air Handler RHLL- Series X-1 (ECM) Efficiencies up to 16 SEER RHLL feature an X-1 (ECM) motor which provides enhanced SEER performance with most Ruud outdoor units. Versatile

More information

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h

DZ14SA. Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF. Cooling Capacity: 18,000-60,000 BTU/h Heating Capacity: 18,000-60,000 BTU/h Cooling Capacity: 18,000-60,000 Heating Capacity: 18,000-60,000 Energy-Efficient Split System Heat Pump Up to 15 SEER & 9.0 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model MSA(4,6)BF Series M120 Product Line Extra High Efficiency Air Conditioner 16 SEER 2-5 Ton Capacity 2 The MSA(4,6)BF Series of Maytag air conditioners offers exceptional performance.

More information

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity

VT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity TECHNICAL SPECIFICATIONS VT4BF-KA/B Series Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton The VT4BF-KA/B series now offers the choice of a heat pump that uses a more efficient and environmentally

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology

More information

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h Split System Heat Pump Up to 16 SEER & 9.5 HSPF Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump TECHNICAL SPECIFICATIONS JT4BD Series 13 SEER 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump 3, 4, 5 Ton Capacities The JT4BD Series heat pump, when combined with our engineered

More information

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER

GSZ14. High-Efficiency, R-410A 1½ to 5 Tons. up to 14 SEER High-Efficiency, R-410A 1½ to 5 Tons Cooling Capacity: 18,000 to 57,600 BTU/h Split System Heat Pump up to 14 SEER Heating Capacity: 18,000 to 59,000 BTU/h Standard Features R-410A chlorine-free refrigerant

More information

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Energy-Efficient Split System Heat Pump 1½ to 5 Tons Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling

More information

HCH6. Product Specifications

HCH6. Product Specifications HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland

More information

N4A6. Product Specifications

N4A6. Product Specifications ENVIRONMENTALLY SOUND REFRIGERANT N4A6 Product Specifications EFFICIENT UP TO 16.5 SEER/12.2 13.0 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BF-K(B,C) Series M1200 Product Line Extra High Efficiency Air Conditioner 16 SEER 2-5 Ton Capacity The PSA4BF-K(B,C) Series of Maytag air conditioners offers exceptional

More information

JS4BF-K(A,B) Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

JS4BF-K(A,B) Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS JS4BF-K(A,B) Series R-410A Extra High Efficiency Air Conditioner 16 SEER Residential System 2-5 Ton The JS4BF-K(A,B) Series now offers the choice of an air conditioner that uses

More information

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Split-System heat pump Up to 14 SEER / R-410A Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data...

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSH1BF Series M1200 Product Line Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton Capacity The PSH1BF Series of Maytag heat pumps offers exceptional performance as well as

More information

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology

More information

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use

More information

VS4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner. 14 SEER Residential System 1.

VS4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Air Conditioner. 14 SEER Residential System 1. TECHNICAL SPECIFICATIONS VS4BE Series R-410A High Efficiency Air Conditioner 14 SEER Residential System 1.5 5 Ton Capacity The VS4BE Series now offers the choice of an air conditioner that uses a more

More information

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT NXA6 Performance Series Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY

JT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally

More information

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H PRODUCT SPECIFICATIONS 14 SEER / R-410A 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER The Goodman Air Conditioner uses the environmentally friendly refrigerant

More information

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor Air Handlers Rheem Air Handlers RHLP- Standard Efficiency X-13 (ECM) Motor RHLP features an X-13 (ECM) motor which provides enhanced SEER performance with most Rheem outdoor units. 1 1 /2 ton [.3 kw] through

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable

More information

TSA6. Product Specifications. SmartComfort TXC 5600

TSA6. Product Specifications. SmartComfort TXC 5600 ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230

More information

WCA4**4. Product Specifications

WCA4**4. Product Specifications WCA4**4 AIR CONDITIONER EFFICIENT 14 SEER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

FT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity

FT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS FT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity The FT4BD Series now offers the choice of a heat pump that uses a more efficient and

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BG Series M1200 Product Line Ultra High Efficiency Air Conditioner 20 SEER Residential System 2-5 Ton Capacities 2 The iq Drive air conditioner system features modulating

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

JS6BD-K Builder's Series

JS6BD-K Builder's Series TECHNICAL SPECIFICATIONS JS6BD-K Builder's Series R-410A High Efficiency Air Conditioner 13 SEER Residential System 2 5 Ton Capacity The JS6BD-K Series now offers the choice of an air conditioner that

More information

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

FORM NO. PTZ-806 REV. 1 HEAT PUMPS FORM NO. PTZ-806 REV. 1 TZPLS-14 SERIES Efficiencies: 15 SEER/12.5 EER 9 HSPF Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured for Thermal

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

COMMERCIAL H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT COMMERCIAL H4A3 DX 1300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER 3 Phase Light Commercial R-410A High Efficiency Heat Pump WARRANTY

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER 3 Phase Light Commercial R-410A High Efficiency Heat Pump WARRANTY TECHNICAL SPECIFICATIONS JT4BD Series 13 SEER 13 SEER 3 Phase Light Commercial R-410A High Efficiency Heat Pump 3, 4, 5 Ton Capacities The JT4BD Series of heat pumps offers exceptional performance with

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12. TECHNICAL SPECIFICATIONS S6BQ Series Split System 2-Stage Air Conditioner 7 1/2 and 10 Ton rated at 11.2 EER and 12.9 IEER The S6BQ Series of air conditioners offers exceptional performance. The unit,

More information

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from

More information

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz 3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator

More information

N4A4 C. Product Specifications

N4A4 C. Product Specifications COASTAL 14 SEER AIR CONDITIONER 14 SEER/11.5 12.5 EER R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Filter drier

More information

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons

GSZ16. High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ooling apacity: 18,000 to 60,000 Heating apacity: 18,000 to 60,000 High-Efficiency Split System Heat Pump Up to 16 SEER & 9.0 HSPF 1½ to 5 Tons ontents Nomenclature... 2 Product Specifications... 3 Expanded

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSH4BF-KA/B Series M1200 Product Line Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton 2 The PSH4BF-KA/B Series of Maytag heat pumps offers exceptional performance as well

More information

FSH1BE Series. High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 14 SEER Residential System 1 1/2 5 Ton Capacity

FSH1BE Series. High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 14 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS FSH1BE Series FEATURES and BENEFITS High Efficiency Heat Pump Designed Using Galvanized Steel: With a polyester urethane coat finish, it passes 9 hours of salt spray per ASTM Std.

More information

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFN- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Ruud Indoor Coils are designed for use

More information

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,

More information

FSH1BF Series. Extra High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 16 SEER Residential System 2-5 Ton Capacity

FSH1BF Series. Extra High Efficiency Heat Pump TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 16 SEER Residential System 2-5 Ton Capacity TECHNICAL SPECIFICATIONS FSH1BF Series FEATURES and BENEFITS Extra High Efficiency Heat Pump CoreSenseTM Compressor Protection: Control module actively monitors compressor conditions and will shut the

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1. TECHNICAL SPECIFICATIONS JT4BE Series High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series of heat pumps offers exceptional performance. The unit, when combined with

More information

GSC13 Split System Air Conditioner

GSC13 Split System Air Conditioner Split System Air Conditioner 13 SEER / R-22 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 AHRI Ratings... 18 Wiring Diagram... 19 Dimensions... 20 Accessories...

More information

ET4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. ET4BD Series R-410A High Efficiency Heat Pump WARRANTY

ET4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. ET4BD Series R-410A High Efficiency Heat Pump WARRANTY TECHNICAL SPECIFICATIONS ET4BD Series ET4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1 1/2 5 Ton Capacity WARRANTY FEATURES and BENEFITS R-410A Refrigerant: Earth friendly non-ozone

More information

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain

More information

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

H4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Copeland

More information

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF High-Efficiency Cooling Capacity: 18,000 to 57,600 BTU/h Heating Capacity: 18,000 to 59,000 BTU/h Split System Heat Pump Up to 15 SEER & 8.5 HSPF Contents Nomenclature... 2 Product Specifications... 3

More information

CSA6. Product Specifications. SoftSound SXC 2600

CSA6. Product Specifications. SoftSound SXC 2600 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models

More information

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz R4A3 Product Specifications REFRIGERATION CIRCUIT S Scroll compressors

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h Cooling Capacity: 18,000-60,000 BTU/h Split System Heat Pump 13 SEER / R-410A Heating Capacity: 18,000-59,000 BTU/h Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor

More information

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

Product Specifications EFFICIENT 13 SEER AIR CONDITIONER EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 1-1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scrollt compressors on all

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model MSH4BF-KA/B Series M120 Product Line R-410A Ultra High Efficiency Heat Pumps 16 SEER 2-5 Ton 2 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors

More information

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity TECHNICAL SPECIFICATIONS FS5BD-KA Series High Efficiency Air Conditioner 13+ SEER Residential System 1.5-5 Ton Capacity The FS5BD Series of air conditioners offers exceptional performance. The unit, when

More information

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER

C4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND REFRIGERANT C4A3 SoftSound SX 2300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

10+ SEER - AIR CONDITIONER

10+ SEER - AIR CONDITIONER 10+ SEER AIR CONDITIONER 1 1 / 2 THRU 5 TONS SPLIT SYSTEM FEATURES Service valves on all models with 3 1 / 2 stubs External refrigerant connections Copper tube / aluminum fin coil Prepainted condenser

More information

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz R2A3 Product Specifications For Use With R 22 Refrigerant AIR CONDITIONER COMPONENT 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model MSH4BE Series M120 Product Line R-410A High Efficiency Heat Pump 14 SEER 1.5-5 Ton Capacity 12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS 550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION

More information

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil Brass

More information

HSH5. Product Specifications. Quiet Comfort DXC 1500

HSH5. Product Specifications. Quiet Comfort DXC 1500 ENVIRONMENTALLY SOUND REFRIGERANT HSH5 Quiet Comfort DXC 1500 Product Specifications 15 SINGLE STAGE HEAT PUMP WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information