Ventilation Control VCM 1004

Size: px
Start display at page:

Download "Ventilation Control VCM 1004"

Transcription

1 Instruction for use Ventilation Control VCM 00 control panel groups drive groups central button rain detector/ room temperature control mains supply 0VAC / 50Hz Ventilation Control Module VCM 00 In: 0VAC / 50Hz Out: VDC / A P L P L P L P L Auto a b a b a b a b Power SET Variostat group window contact IR remote control IR receiver or control panel quadruple with integrated IR receiver Application /0/0 The ventilation control module VCM 00 is suitable for daily ventilation and can simultaneously trigger up to groups. The ventilation control is universally applicable due to its latest state of the art and very small dimensions. Window drives, louver drives or electric jalousies can be alternatively on every individual group. Special functions per group output can be allocated via a programming mode. The ventilation control module can be directly integrated in the house distributing box, or surface/ or flush mounted using housings, optional available. Different detectors can be allocated to every group (wind/ or rain detectors, thermostat switches, timer, actuator of the Building Management System). Programming is effected direct on the control. The groups are operable via remote controls, wall control panels or vent buttons as well as direct on the VCM 00. Two of the Variostat groups can be additionally with dependence on the ventilation groups. D+H Mechatronic AG GeorgSasseStr. 8 D99 Ammersbek Tel Fax

2 Content Please observe!/ Software state... Technical Data / Guarantee... Front view/ Pictograph... Accessories... Wiring plan, line lenghts, cross sections... 5 Connecting plans Adjusting of address control panels... 8 Configuration... 9 Programming functions: group allocation central inputs... 0 group allocation vent button inputs... Example for application: with one VCM with two VCM Open/ Close/ Stop via: the front panel... control panels... 5 Control 0 minutes ventilation... 6 Control Variostat... 6 Technical Data Rated voltage : 0VAC / 50Hz Power consumption : 0VA Interfering emission : DIN EN 550 DIN EN 5008, DIN EN 6000, DIN EN 6000, DIN EN Resistance to jamming : DIN EN 6000 to 6, DIN EN 500 Protective category : II Protective system : IP0 Class of rating : Shorttime Output voltage : VDC/ Residual ripple < 5% safe output current : A / ED0 working temperature : 050 C / max. 70% rel. H Dimensions (wxhxd) : 60 x 90 x 65 for top hat rail mounting Outputs are short circuit proof; with that conventional fuses are dropped. Please observe! This instruction includes descriptions and connecting plans of components, which are contained in extent of supply of the control panel. You can get these parts and many other ones separate at your D+H distributor. Further connecting plans are available there as well. VDE 000 for electric systems and regulations of EVU for electric mains have to be observed. Remove after installation / before switching on! Nach der Installation / vor Inbetriebnahme entfernen! Software revision Guarantee Do remove label on ventilation slots before mounting of the VCM 00. These instruction are valid as of software revision C60A0! Software state C60A0 Ventilation Control Module VCM 00 You will get years guarantee for all D+H products from date of verified handing over of the system up to maximal years after date of delivery, when mounting and starting has been carried out by a D+H authorized distributor. D+H guarantee is expired, with connection of D+H components with external systems or with mixing of D+H products with parts of other manufacturers. /6 VCM 00 Rev.:.

3 Front View P L P L P L P L a b a b a b a b Ventilation Control Module VCM 00 In: 0VAC / 50Hz Out: VDC / A Auto Power SET N L Power supply 0VAC / 50Hz / 0VA +5,7V SCL SDA IR C C on C on Pictograph Explanation Accessories Drives SET Auto Auto Central inputs Louver / Jalousie Window levels/ Programming mode Automatic safety function in direction Open Automatic safety function in direction Closed Control panel Electro motor drive Voltage Variostat VCD on a roof window Mounting of the drive: VCD on pivothung window opening inward You will find the mounting instructions in the instruction for use of the drive. VCM 00 Rev.:. /6

4 ( ( Accessories Room temperature control RTR 8 Room temperature control for controlling of ventilation via roomtemperature. Switching range adjustable from 5 0 C. IRreceiver IE 0B External receiver for IRremote control. Mounting on 55mm flush box or in suspended ceiling C 0 Rain detector VRS 0 Rain detector for automatic closing of windows in case of rain. Variostat VST 0 The heat valve will be automatically closed during every ventilation process through electronic triggering via window contacts, window drives, wall/ or IRremote controls. Consequently, energy costs will be saved. Vent Buttons and Control Panels LÜFTUNG LT U Vent buttons for controlling of individual drive groups. Several vent buttons can be in parallel per group. Mounting in 55 mm flush box ( included). Surface frame available as accessories. LF 0A Control panel (mounting on 55mm flush box) for window drives, heating radiator (Variostat) and shading systems LF 0B Control panel (mounting on 55mm flush box) for window drives, heating radiators (Variostat) and shading systems with integrated infrared receiver IS 0 Remote control for window drives, heating radiators (Variostat) and shading systems /6 VCM 00 Rev.:.

5 Wiring Plan (Paragon) to further ones to further ones M IY (St) Y xx0,6 Drive see line length and cross sections control panel 0VAC NYMI x,5 vent button ATTENTI! Control panel double Install and feed weak current lines separately from supply mains. IY (St) Y xx0,6 Control panel quadruple with IRreceiver IY (St) Y xx0,6 max. 50m rain detector IY (St) Y xx0,6 max. 50m IY (St) Y xx0,6 receiver VDC external control e.g. D+H vario IY (St) Y xx0,6 IY (St) Y xx0,6 room temperature control Line lengths and Cross sections: Earthed conductor must be wired! 0,5A 5 6 Antriebe / 0,5A drives A x 0,5mm² x 0,75mm² x mm² x,5mm² cross section (mm²) = simple cable length (m) x number of drives 80*** ***Applies only for drives with A drive current. Use drive current 60 for drives with 0,5A and drive current 0 for drives with 0,5A. See also page 7 to this! VCM 00 Rev.:. 5/6

6 Connection Vent Buttons, Detectors P L P L LTclosed LTopen LEDopen LTclosed LTopen LEDopen LTclosed LTopen LEDopen LTclosed LTopen LEDopen Control panel twofold LF 0A rt rt rt P L P L rt N closed open open signal closed open open signal N closed open open signal N closed open open signal L L Central button Level Level L L VCM 00 < optional > Vent button LT U L L open closed N Rain detector VRS 0 optional < > R Roomtemperaturecontrol RTR Regen +V open closed N Zz Za +V Zz Za 6/6 VCM 00 Rev.:.

7 Connection Drives Running direction of drives: Change poles of lines ( Mot.a and Mot.b ) of drive supply if running direction is wrong. Maximum number of drives: brunch box bl br bl br per group max. A: 6 drives with 0,5A each, or drives with 0,5A each, or drives with A each Mot.a Mot.b Mot.a Mot.b Mot.a Mot.b Mot.a Mot.b all groups together max. A: drives with 0,5A each, or 8 drives with 0,5A each, or drives with A each a b a b a b a b VCM 00 Connection Variostat, Window Contact, BUS, IR +5,7V SCL SDA IR VCM 00 C on C C on shield (connect only in central control) factoryset DIPswitch +5,7V SCL SDA IR 5 LF 0B Control panel quadruple heating : reduction heating : on Heating : reduction heating : on window contact window contact Variostat Variostat +5,7V IR IE 0B IRreceiver VCM 00 Rev.:. 7/6

8 Adjusting of Address Control Panels IS 0 Remote control LF 0B Control panel quadruple OPEN CLOSE = OPEN = OFF group group Variostat OFF OFF group group Variostat OFF group group Variostat OFF group group group OFF group LF 0B IS 0 group pole DILswitch group Variostat Variostat OPEN DILswitch pole 8/6 VCM 00 Rev.:.

9 Configuration Activation Central open/ closed / LED lightens Deactivation Central open/ closed / LED is extinguished Activation Variostat/ LED lightens Deactivation Variostat/ LED is extinguished Central open/ closed Central open/ closed Variostat Variostat Auto Safety function switched off * / LED lightens through briefly pressing of the running direction button the window / the louver will automatically open or close up to the stopp position Safety function switched on * / LED is extinguished when opening the window / the louver, keep running direction button pressed until the desired opening width is reached; when closing the window / the louver, keep running direction button pressed Windows/ louvers do close automatically, (in case of wind/ rain, temperature either) Activation louver/ jalousie LED lightens 0 minutes ventilation possible! Activation windows/ LED is extinguished * Auto / safety function: windows, which are within arm's reach, can only be opened or closed when the vent button is kept pressed. If the safety function is activated (LED is extinguished), the remaining functions (0 minutes ventilation, central open/closed) are activated. Several functions are programmable per group. Central open / closed has uppermost function priority. Safety function VCM 00 Rev.:. 9/6

10 Programming Function The VCM 00 has two central inputs for the function Open and Closed. Central input and/ or central input can be allocated to every single group. You can optionally connect to central inputs + a rain detector, thermostat switch, central button, timer, wind detector or an actuator of the Building Management System (e.g. EIB BUS). The central inputs are wired via floating contacts. Example for application: central input / rain detector motor groups + / window opener motor groups + / louver drives. The central input will be programmed on group + (LED lightens). The louver will be activated on group + (LED lightens). If it starts raining now, the window drives will automatically close. If you connect e.g. an external timer to central input, you will have activated central input for group + with this, and can only open and/or close the louvers via the timer. Adjusting of s Power Power Power Power Power Power * * * * SET SET SET SET SET SET Sec. x x x x * Configuration of group = = OFF 0/6 VCM 00 Rev.:.

11 Programming Function: group allocation vent button inputs Vent button inputs as well as IRremote controls (VIS 0) and D+H bus fields (LF 0B) can be freely allocated to the groups. Possibility of combining groups or of controlling two VCM 00 with a remote control. Sec. Power Power SET SET SET x Power Power Power Power * * * SET SET SET SET x x x * Configuration of vent button inputs = = OFF VCM 00 Rev.:. /6

12 Example for Application with one VCM 00 M M M M Allocation Release group Vent button x will be released M M M M /6 VCM 00 Rev.:.

13 Example for Application with two VCM 00 VCM 00 VCM 00 Gruppe Gruppe Gruppe Gruppe Control level x will be released VCM 00 VCM 00 M M LÜFTUNG M VCM 00 M LÜFTUNG M VCM 00 M LÜFTUNG M VCM 00 M M LÜFTUNG M VCM 00 VCM 00 Rev.:. /6

14 Open/ Close/ Stop via Frontfield VCM 00 Opening. Press button. Depending on configuration LED on Of the group, the electric drive will automatically open up to its stop position after a single pressing of the button or only as long as the button is pressed. Power Closing SET Press button. Depending on configuration of the group, the electric drive will automatically close up to its stop position after a single pressing of the button or only as long as the button is pressed. Stoppen For stopping of the drive in any intermediate position press either once again the same running direction button simultaneously the buttons Open and Closed 0 s. groups are stopped...s. groups run in Closeddirection or LED off < Sec. /6 VCM 00 Rev.:.

15 ( ( ( Opening/ Closing of s on VCM 00 IS 0 / LF 0A / LF 0B IS 0 / LF 0A / LF 0B Ventilation Ventilation LT U LT U STOP STOP < Sec. LÜFTUNG < Sec. STOP STOP VCM 00 Rev.:. 5/6

16 ( ( Control 0 Minutes Ventilation LÜFTUNG IS 0 / LF 0A / LF 0B LED flashes When pressing simultanously both the buttons ( + ) on control panel/ vent button, automatic ventilation will be carried out, which will be limited to 0 minutes. (Only if the safety function is deactivated). If a Variostatheating control is as well, the radiator valve will additionally close complete for 0 minutes. The yellow LED in the Variostat will lighten. Possibility of closing from this position any time with button. Control Variostat LED flashes Reduction OFF By pressing of button the reduction of heating temperature will be undone again. IS 0 / LF 0A / LF 0B Reduction By pressing of button the temperature set on heating radiator will be reduced by about 6 C. 6/6 VCM 00 Rev.:. All sizes in millimetre Rights to technical modifications reserved. Reprinting and phototechnical reproduction also in extracts has to be expressively authorized by D+H Mechatronic AG.

GVL 8301-K CNV control panel

GVL 8301-K CNV control panel GVL Series GVL 8301-K CNV control panel Performance features Compact ventilation control panel For controlling 24 V DC window drives Up to 1 A total drive current 1 ventilation group Input for external

More information

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control

Version 11 Controls for natural ventilation. NV Comfort Standard / Plus KNX control Version 11 Controls for natural ventilation NV Comfort Standard / Plus KNX control NV Comfort software card 230V 1.20 NV Comfort basis package Application central control of indoor climate with the potential

More information

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL S000 / S000 SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR MODULATING AND FLOATING CONTROL GENERAL These direct-coupled damper actuators provide modulating / floating control for:

More information

Technical Manual DICTAMAT 304 AZ. Door Drive Unit. for hinged lift landing doors. Technical Data

Technical Manual DICTAMAT 304 AZ. Door Drive Unit. for hinged lift landing doors. Technical Data Door Drive Unit The is an electrical door drive unit which automatically opens hinged lift doors up to 200 kg. As the operating arm is not directly fixed to the door, all landing doors in the lift can

More information

S1024-2POS / S POS S2024-2POS / S POS

S1024-2POS / S POS S2024-2POS / S POS GENERAL S0-POS / S00-POS S0-POS / S00-POS SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 0/0 Nm (88/77 lb-in) FOR -POSITION CONTROL These direct-coupled damper actuators provide two-position control for:

More information

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3 Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Instructions. Angle Seat Control Valve. Type 7020 Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:

More information

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Door Control Panel TS 960. instructions. (Design and functions subject to change) / Electrical operating Operating instructions Door Control Panel TS 960 GB (Design and functions subject to change) 51171098 / 10.2002 OPERATING INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 FUNCTION OVERVIEW...6

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

AeroVironment Universal Solar Pump Controllers

AeroVironment Universal Solar Pump Controllers AeroVironment Universal Solar Pump Controllers (Installer s business information to be affixed here.) User Manual Models: USPC-2000 (AV Part Number 03747-001 Rev. D) USPC-5000 (AV Part Number 03747-002

More information

AirLINE and AirLINE Quick electrical/pneumatic Automation System

AirLINE and AirLINE Quick electrical/pneumatic Automation System AirLINE and AirLINE Quick electrical/pneumatic Automation System Type 8644 can be combined with Fully compatible with Rockwell Combination of Fieldbus, pilot valves and I/O modules higher fl exibility

More information

3200NT Timer Service Manual

3200NT Timer Service Manual Service Manual Valve Serial Number Valve Position 1-LEAd 2-LAg 3-LAg 4-LAg IMPORTANT: Fill in pertinent information on page 3 for future reference. Table of Contents Job Specifications Sheet.....................................................................

More information

TECHNICAL CATALOGUE. Softstarter range. CNABB /1SFC en, May-2000R

TECHNICAL CATALOGUE. Softstarter range. CNABB /1SFC en, May-2000R TECHNICAL CATALOGUE Softstarter range CNABB /1SFC 288001-en, May-2000R 07-2000 1 8/3/00, 1:11 AM Contents Description 3 Ordering Data PS S 4 Accessories PS S 5 Ordering Data PS D 6 Ordering Data PS DH

More information

Product information. ORION-PB Poultry computer for floor keeping

Product information. ORION-PB Poultry computer for floor keeping Product information Hotraco Agri BV Stationsstraat 142 5963 AC Hegelsom Tel +31 (0)77 327 50 20 Fax +31 (0)77 327 50 21 info@hotraco.com www.hotraco.com ORION-PB Poultry computer for floor keeping Poultry

More information

Local Control Network - building controls in perfection

Local Control Network - building controls in perfection 2 1 F3,15A250V 2 1 1 2 F3,15A250V Installation guide Local Control Network - building controls in perfection Sensor/actuator module for DIN-rail mounting The is a sensor/actuator module for building installation

More information

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection MANUAL CONGRATULATIONS on the purchase of your new CTEK charger providing professional battery care. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote

More information

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

SBC V In-Car Charger Dual Input (Solar MPPT & DC) SBC-5926 12V In-Car Charger Dual Input (Solar MPPT & DC) Operation manual Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions

More information

ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX DG/S x DALI-Gateway Basic ABB i-bus KNX DG/S x.64.1.1 DALI-Gateway Basic The lamps are variably controlled via KNX per DALI output via Broadcast (all lamps jointly) 16 lighting groups 64 individual lamps 16 scenes 64 self-contained

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

Operating manual UPS - System

Operating manual UPS - System Operating manual UPS - System POWERMASTER M MIL 1000VA 7Min. BAX 3330 E UPS-Division Issued 15. August 2006 JOVYATLAS JOVYATLAS Elektrische Umformtechnik GmbH Groninger Straße 29-37 D-26789 Leer/Ostfriesland

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017 R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating

More information

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak

More information

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the : 55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V

More information

Design specifications

Design specifications Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor

More information

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0 Products Tde Macno User s Manual BRAKING UNIT Cod. MP00401E00 V_1.0 SUMMARY 1 GENERAL DESCRIPTION... 2 2 USE LIMITATIONS... 2 2.1 Climatic Class... 2 2.2 Resistance To Chemically Active Substances...

More information

Central battery system ZB-S with STAR technology

Central battery system ZB-S with STAR technology Central battery system ZB-S with STAR technology As well as providing a dependable supply of power (30V AC/0 V DC) to safety and exit luminaires, the central battery system ZB-S tests itself automatically

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC Automatic Battery Charger Switching mode with Micro-controlled Input:220-260Vac / Output: 12Volt DC User s Manual and Important Safety Information Model: OC-SW121080 / OC-SW121160 / OC-SW121210 FEATURES

More information

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire

More information

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers frost protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Heating systems protect pipes, valves, actuators and other elements vulnerable to harmful influence

More information

LINOCUR Size D02 63A 230VAC/440VAC

LINOCUR Size D02 63A 230VAC/440VAC IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL DC FREE COOLING UNIT SYSTEM AIR CONDITIONER MODELS DAPA DLPA DAPA DLPA DAPB DLPB CONTROLLER MODELS LC00 LC0 LC000 Description Page Cabinet Components Exploded View... Usage List...

More information

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft. Solenoid Coils Armature Assemblies Valve Systems Nass Controls LP Nass Magnet GmbH Precision Controls Kft. Introduction......................................... Page 4-5 Solenoid Coil Width 22 mm Connection

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS TABLE OF CONTENTS 1.0 - WARNINGS 2.0 - GENERAL DATA 2.1 - Technical characteristics 2.2 - Data on electrical

More information

ZonePlus Z322 zone valve Installation and commissioning instructions

ZonePlus Z322 zone valve Installation and commissioning instructions ZonePlus Z322 zone valve Installation and commissioning instructions The Z322 mid-position valve has been designed to control the water circulation in fully pumped systems, which employ a single pump for

More information

QUASAR Chain actuator - Force in push action 300 N - Maximum stroke 500 mm

QUASAR Chain actuator - Force in push action 300 N - Maximum stroke 500 mm QUASAR Chain actuator - Force in push action 300 N - Maximum stroke 500 mm Highest performance in minimum size: the die-cast aluminium casing has a very small section (47 x 32 mm) and can be easily built-in

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23. Pressure Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS23.100 and PGS23.160 k Applications for further approvals see page 7 WIKA data sheet PV 22.02

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

SPECIFICATIONS LOW COST 2404S CHARGER

SPECIFICATIONS LOW COST 2404S CHARGER 6033 Shawson Dr., Unit 29, Mississauga Ontario, Canada L5T 1H8, e-mail: info@soneil.com Ph.: 905 565 0360 Fax: 905 565 0352 Visit us on the web at www.soneil.com SPECIFICATIONS LOW COST 2404S CHARGER Totally

More information

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions

1 Safety instructions. 2 Device components. Blinds Management Motor control insert Universal AC 230 V ~ Art. No. 232 ME. Operating instructions Art. No. 232 ME Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC Automatic Battery Charger Switching mode with Micro-controlled Input:220-260Vac / Output: 12Volt DC User s Manual and Important Safety Information Model: OC-SW121080 / OC-SW121160 / OC-SW121210 FEATURES

More information

Type Electrically Actuated Ball Valve

Type Electrically Actuated Ball Valve Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement socket, threaded,

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants World Class Power Solutions Rectifiers For Stationary Battery Systems in Nuclear Power Plants General 2 1.1 Application Electronically controlled rectifier assemblies are used in conjunction with suitable

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions electronic Softstarter SAS 3...11 SAS 11PUST, 22PUST Assembly- and Commissioning Instructions Quality is our Drive. SAS 3...11, SAS 11PUST, 22PUST 1 Stand 03/17 10800.10002 Table of contents Page 1. Safety

More information

4 relays DIN actuator

4 relays DIN actuator TECHICA SHEET relays DI actuator Description By means of internal relays, this device executes the controls received from the central unit or from the probe. It is needed to control loads such as - -coils,

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

MF4E MF4E

MF4E MF4E MF4E-60830-100 TAC DuraDrive Non-Spring Return Floating Actuator General Instructions Application The 35 lb-in. (4 N-m) and MF4E-60830-100 70 lb-in. (8 N-m) non-spring return, direct-coupled actuators

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

Type Electrically Actuated Ball Valve

Type Electrically Actuated Ball Valve GF Piping Systems Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement

More information

RVD235. G2385en. Installation without base

RVD235. G2385en. Installation without base 2382Z04 G2385en en Installation Instructions District heating controller for one heating circuit and d.h.w. RVD235 Installation without base Place of installation Compact station front or control panel

More information

Table of Contents. For latest version, visit:

Table of Contents. For latest version, visit: Table of Contents 1.0 Introduction... 1.0 Overview... 1 3.0 Test Set Controls... 6 3.1 Power... 6 3. Time Display... 6 3.3 Timer Clear Push Button... 6 3.4 Start Push Button and LED... 6 3.5 Stop Push

More information

ELECTRIC LINEAR ACTUATOR - MAX

ELECTRIC LINEAR ACTUATOR - MAX ELECTRIC LINEAR ACTUATOR - MAX MAX VOLTAGE SUPPLY 230 Vca ±10% PARALLEL CONNECTION YES STROKE 300/500 mm LIMIT STOP Microswitches FORCE IN PUSHACTION 450 N (300 mm) / 350 N (500 mm) SAFETY STOP Thermic

More information

Controls. remotes & Accessories

Controls. remotes & Accessories Controls remotes & Accessories Telis Collection... 2-3 Remote Operation... 4 Hand Held RTS Remotes... 5-6 Wall Mounted Wireless Switches Collection...7-10 Touch Screen Control... 11 Universally Controlled

More information

Low-Voltage Motors N-compact Standardline Operation on supply system

Low-Voltage Motors N-compact Standardline Operation on supply system Low-Voltage Motors N-compact Standardline Operation on supply system 2 2/2 Overview 2/2 Benefits 2/2 Technical specifications 2/2 Selection and Ordering Data 2/ Options 2/ Dimensional drawings 2/4 More

More information

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided

More information

RVD110 RVD G2381en. Installation. Commissioning

RVD110 RVD G2381en. Installation. Commissioning 4 319 2788 0 G2381en en Installation Instructions District heating and d.h.w. controller RVD110 RVD130 Installation Place of installation In a dry room, e.g. the heat exchanger room Mounting choices: -

More information

Model Specifications Code Price FOTOSWITCH

Model Specifications Code Price FOTOSWITCH D type device (EN 12453) Flush mounted photocells FOTOSWITCH Installation: embedded or on column Absorption 90 ma Protection class: IP44 Directional photocell with alignment Obstacle detection time: 7

More information

EMO TM. Actuators High performance proportional actuator For modulating control

EMO TM. Actuators High performance proportional actuator For modulating control EMO TM Actuators High performance proportional actuator For modulating control IMI TA / Actuators / EMO TM EMO TM A proportional thermoelectric actuator which, when used together with the TA-Modulator,

More information

Original BMW Accessories. Installation Instructions.

Original BMW Accessories. Installation Instructions. Original BMW Accessories. Installation Instructions. Anti-Theft Alarm System Retrofit BMW 3 Series Saloon (E90) BMW 3 Series Coupé (E92) Retrofit kit no.: 65 2 0 399 635 Anti-theft alarm system retrofit

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels

More information

Power Supply EL

Power Supply EL General information: EL630-1203-7 has been specifically developed to meet the DC powering requirements for telecommunications, industrial and marine applications. The output is current limited, with short

More information

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S Product Manual ABB i-bus EIB EIB Power Supply Units SV/S 30.320.5 SV/S 30.640.5 SU/S 30.640. Intelligent Installation Systems Contents Page EIB Power Supply Units. Introduction.........................................

More information

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev / SSP-7080 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing USER MANUAL Rev.1.1 2007/04 7673-7080-0000 CONTENTS Warning, Cautions and Operating Conditions P.1 Introduction

More information

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , , ROBUST LED DRIVERS EasyLine INDUSTRY 186452, 186453, 186454, 186455, 186456, 186477, 186510, 186617 Typical Applications Built-in in compact luminaires for Industrial lighting EasyLine Industry ENCAPSULATED

More information

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No Document No. 155-521 (For Use with 2-1/2-Inch to 6-Inch Pressure Independent Control Valves) Features Operating voltage: AC/DC 24V Application Control signals: 3-position, DC 0 to 10V, DC 4 to 20 ma Fail-safe

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

Modular pneumatic valve unit

Modular pneumatic valve unit Modular pneumatic valve unit Compact design Modular configuration High flexibility Type 8640 can be combined with Simple exchange of valves (with option P-shut-off - also possible during operation) Type

More information

Electro-Mechanical Swing Operator. Table of Contents

Electro-Mechanical Swing Operator. Table of Contents *640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product

More information

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives Safety Interlock Switches DSL Compact -Contact uard Lock Safety-Door Switch Two types are available: a connector type that reduces wiring time and a detachable terminal block type. Robust and durable metal

More information

3SE3 1 SIGUARD Position Switches

3SE3 1 SIGUARD Position Switches 3SE3 SIGUARD Position Switches Metal-enclosed, with Moulded Cable Description Technical data Description In harsh industrial environments and in installations with limited space, the small 3SE3 6 and 3SE3

More information

24V 3A EN54 Ancillary Power Supply

24V 3A EN54 Ancillary Power Supply 24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION

More information

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11 2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation

More information

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

RVD125/109 RVD145/109

RVD125/109 RVD145/109 G2511 en Installation Instructions District heating and d.h.w. controller RVD125/109 RVD145/109 Installation without base Place of installation Compact station front or control panel front Permissible

More information

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100... 2.0 LabSystem Fume hood monitors Table of contents Section Title Page 1.1 Introduction..................................... 2 2.1 Functional description............................. 2 2.1.1 Actual value

More information

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual DIN Rail UPS Model: DIN-UPS 24-10 Installation/Operation Manual Table of Contents Section Page Section Page Quick Start 2 1) General Information 4 Materials Provided 4 Optional Equipment 4 2) Safety Information

More information

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Braking Devices BR 230/ Assembly- and Commissioning Instructions electronic Braking Devices BR 230/400-10...400 Assembly- and Commissioning Instructions Quality is our Drive. BR 230/400-10...400 1 as per 04/10 11600.10001 Table of Contents Page 1. Safety notes 3 2.

More information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- - Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head

More information

Distribution Blocks & Bus-bar Solutions

Distribution Blocks & Bus-bar Solutions Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided

More information

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

31-SDMS-02 REV. 01 SPECIFICATIONS FOR 31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P

More information

19 CLOSE RACK & WALL RACK 19 WALL MOUNT RACK. JK Dynamic Co., Ltd. Tel : Fax :

19 CLOSE RACK & WALL RACK 19 WALL MOUNT RACK. JK Dynamic Co., Ltd. Tel : Fax : 19 WALL MOUNT RACK º 19" Wall Mount Rack Design three compartment, front, middle and rear. º Material made of electro galvanized sheet steel 1.2mm.thickness, 100% rust-proof and durable. º Mounting vertical

More information

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877) By CNP INDUSTRIES, INC. P.O. Box 8645 Anaheim, Ca 987 (877) 387-67 VENTILATOR VEN50/VEN00 INSTALLATION INSTRUCTIONS Ventilator Can Be Used For Roof or Wall Mounting Recommended for use over household gas

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

PROFESSIONAL 270 o PIR MOTION DETECTOR

PROFESSIONAL 270 o PIR MOTION DETECTOR PROFESSIONAL 270 o PIR MOTION DETECTOR The unit can be installed only vertically (see the FIGURE 1A), not upside-down or horizontally (see the FIGURE 1B) as shown in the below drawing. FIGURE 1A 1. Motion

More information