Disposal declaration Frequency Converters Frame Size: D1, D2, D3, D4, D5, D6, D7 and D8 (New Generation) Production Place: USA and India

Size: px
Start display at page:

Download "Disposal declaration Frequency Converters Frame Size: D1, D2, D3, D4, D5, D6, D7 and D8 (New Generation) Production Place: USA and India"

Transcription

1 Environmental Product Information l Danfoss Drives Disposal declaration Frequency Converters Frame Size: D1, D2, D3, D4, D5, D6, D7 and D8 (New Generation) Production Place: USA and India At Danfoss, we take into account environmental considerations during the design and development of new products. We collect as much reliable data from suppliers as possible to generate lists of materials and disposal instructions. Ways of dismantling the product depend on national and/or local legislation and the capabilities of the scrapping facilities. This environmental information about the product is based on existing knowledge and available data. That Danfoss facility complies with TS including ISO 9001 and ISO 14001standards. Frequency Converters covered: VLT AutomationDrive VLT HVAC Drive VLT AQUA Drive VLT Refrigeration Drive Danfoss A/S, DK-6430 Nordborg, Denmark, CVR nr.: , Telephone: , Fax: Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation. Document ID: Revision, Sequence: A,2 File Origin Date: File Last Modified:

2 Product information build up and identification File Last Modified: PRODUCT INFORMATION BUILD UP AND IDENTIFICATION Copyright Danfoss A/S, 2016 Page 2 of 18

3 Main Material Content for D1 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D1 (NEW GENERATION) Type D1 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Copyright Danfoss A/S, 2016 Page 3 of 18

4 Drawings File Last Modified: Inductor/Transformer Rubber gaskets Other Materials: (For example Ferrit) Weight of VLT Nr of Printed Circuit Assemblies 10 (With LCP, Without option) Number of LCD s (Maximum) 1 3. DRAWINGS 3D drawing representing Frame Size D1: Copyright Danfoss A/S, 2016 Page 4 of 18

5 Main Material Content for D2 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D2 (NEW GENERATION) Type D2 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Copyright Danfoss A/S, 2016 Page 5 of 18

6 Drawings File Last Modified: Inductor/Transformer Rubber gaskets Other Materials: (For example Ferrit) Weight of VLT Nr of Printed Circuit Assemblies 10 (With LCP, Without option) Number of LCD s (Maximum) 1 5. DRAWINGS 3D drawing representing Frame Size D2: Copyright Danfoss A/S, 2016 Page 6 of 18

7 Main Material Content for D3 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D3 (NEW GENERATION) Type D3 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Copyright Danfoss A/S, 2016 Page 7 of 18

8 Drawings File Last Modified: Inductor/Transformer Rubber gaskets Other Materials: (For example Ferrit) Weight of VLT Nr of Printed Circuit Assemblies 10 (With LCP, Without option) Number of LCD s (Maximum) 1 7. DRAWINGS 3D drawing representing Frame Size D3: Copyright Danfoss A/S, 2016 Page 8 of 18

9 Main Material Content for D4 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D4 (NEW GENERATION) Type D4 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Copyright Danfoss A/S, 2016 Page 9 of 18

10 Drawings File Last Modified: Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Inductor/Transformer Rubber gaskets Other Materials: (For example Ferrit) Weight of VLT Nr of Printed Circuit Assemblies 10 (With LCP, Without option) Number of LCD s (Maximum) 1 9. DRAWINGS 3D drawing representing Frame Size D4: Copyright Danfoss A/S, 2016 Page 10 of 18

11 Main Material Content for D5 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D5 (NEW GENERATION) Type D5 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Copyright Danfoss A/S, 2016 Page 11 of 18

12 Drawings File Last Modified: Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Inductor/Transformer - - Rubber gaskets D1 Drive Weight of VLT Nr of Printed Circuit Assemblies 11 (With LCP, Without option) Number of LCD s (Maximum) DRAWINGS 3D drawing representing Frame Size D5: Copyright Danfoss A/S, 2016 Page 12 of 18

13 Main Material Content for D6 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D6 (NEW GENERATION) Type D6 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Copyright Danfoss A/S, 2016 Page 13 of 18

14 Drawings File Last Modified: Plastics various: (Enclosures) Inductor/Transformer - - Rubber gaskets D1 Drive Weight of VLT Nr of Printed Circuit Assemblies 11 (With LCP, Without option) Number of LCD s (Maximum) DRAWINGS 3D drawing representing Frame Size D6: Copyright Danfoss A/S, 2016 Page 14 of 18

15 Main Material Content for D7 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D7 (NEW GENERATION) Type D7 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Copyright Danfoss A/S, 2016 Page 15 of 18

16 Drawings File Last Modified: Inductor/Transformer - - Rubber gaskets D2 Drive Weight of VLT Nr of Printed Circuit Assemblies 11 (With LCP, Without option) Number of LCD s (Maximum) DRAWINGS 3D drawing representing Frame Size D7: Copyright Danfoss A/S, 2016 Page 16 of 18

17 Main Material Content for D8 (New Generation) File Last Modified: MAIN MATERIAL CONTENT FOR D8 (NEW GENERATION) Type D8 FC-301N FC-102N FC-302N FC-202N T4,T kw kw T kw kw Material Content [kg] (%wt) Aluminium primary (Al): Heatsink,Control unit, Front cover, Cable entry Iron/Steel primary (Fe): Terminal Plate, Side Cover, Coils/Transformers Copper primary (Cu): Coils/Transformers, Busbar Electronics: Printed Circuit Boards (PCB), Components: RFI,LCP,Terminal plate,switchmode, Rectifier, Fan,Cables Plastics various: (Enclosures) Copyright Danfoss A/S, 2016 Page 17 of 18

18 Drawings File Last Modified: Inductor/Transformer - - Rubber gaskets D2 Drive Weight of VLT Nr of Printed Circuit Assemblies 11 (With LCP, Without option) Number of LCD s (Maximum) DRAWINGS 3D drawing representing Frame Size D8: Copyright Danfoss A/S, 2016 Page 18 of 18

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive Installation Guide VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive FC 301/FC 302 Installation Guide VLT Real-time Clock MCB

More information

Control Card VLT FC Series

Control Card VLT FC Series These instructions describe the replacement of the control card in: VLT HVAC Drive FC 102. VLT Refrigeration Drive FC 103. VLT AQUA Drive FC 202. VLT AutomationDrive FC 301/FC 302. VLT Lift Drive LD 302.

More information

Marine Annex covering all VLT Drives Note

Marine Annex covering all VLT Drives Note Marine Annex covering all VLT Drives Note Document ID: 00735874 Rev., Sequence: A,1 Project/ Activity: File Origin Date: File Last Modified Creator: P400 - Platform 2017-03-28 2017-03-28 Jacobsen, Carsten

More information

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302 1.1 Description The 500 A current sensor kit is designed for F1 F4 and F8 F13 enclosure sizes in the power ranges shown in Table 1.1. To identify the power rating, see Illustration 1.1. Product group and

More information

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number. Description The bus bar kit is designed for the specific VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, and VLT AutomationDrive FC 302 D4h-size VLT Parallel Drive Modules mounted in a Rittal TS8 enclosure.

More information

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302 1.1 Description The in-bottom/out-back cooling kit fits the following E4h drives. It is compatible with drives mounted in Rittal TS8 800 mm (32 in) cabinets. VLT HVAC Drive FC 102 VLT Refrigeration Drive

More information

Brake Resistor Design Guide. How to Read this Design Guide 3 Abbreviations 4. Safety Precautions 5 CE Conformity and Labelling 5

Brake Resistor Design Guide. How to Read this Design Guide 3 Abbreviations 4. Safety Precautions 5 CE Conformity and Labelling 5 Brake Resistor Design Guide Contents Contents 1 How to Read this Design Guide 3 How to Read this Design Guide 3 Abbreviations 4 2 Safety and Conformity 5 Safety Precautions 5 CE Conformity and Labelling

More information

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302 1.1 Description The 300 A current sensor kit is designed for D1h/D3h/D5h/D6h enclosure sizes in the power ranges shown in Table 1.1. To identify the power rating, see Illustration 1.1. Product group and

More information

INSTRUCTIONS 177R0076 INSTALLATION OF TOP AND BOTTOM COVERS FOR IP00 FRAMES D3, D4 & E2 INTO RITTAL ENCLOSURES

INSTRUCTIONS 177R0076 INSTALLATION OF TOP AND BOTTOM COVERS FOR IP00 FRAMES D3, D4 & E2 INTO RITTAL ENCLOSURES INSTRUCTIONS 177R0076 INSTALLATION OF TOP AND BOTTOM COVERS FOR IP00 FRAMES D3, D4 & E2 INTO RITTAL ENCLOSURES This instruction sheet is for the installation of the top and bottom covers onto IP00 VLTs

More information

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302 Description The 500 A current sensor kit is designed for D2h/D4h/D7h/D8h enclosure sizes in the power ranges shown in Table 1.1. To identify the power rating, see Illustration 1.1. Product group and drive

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE Page 1 / 9 File number: AP 63 Product code: 2592I This certificate is not valid when presented without the full attached schedule composed of 7 sections www.veristar.com Requirements: Bureau Veritas Rules

More information

FREQUENCY CONVERTER DANFOSS FC101 NOVENCO CONFIGURATION USER GUIDE

FREQUENCY CONVERTER DANFOSS FC101 NOVENCO CONFIGURATION USER GUIDE FREQUENCY CONVERTER DANFOSS FC101 NOVENCO CONFIGURATION USER GUIDE Pure competence in air. ENGLISH 926867-0 926867-0 GB Frequency converter Danfoss FC 101 Novenco configuration user guide Contents 1.

More information

ABB drives. Recycling instructions and environmental information ACS880-11, ACS880-31, ACH and ACQ drives

ABB drives. Recycling instructions and environmental information ACS880-11, ACS880-31, ACH and ACQ drives ABB drives Recycling instructions and environmental information ACS880-11, ACS880-31, ACH580-31 and ACQ580-31 drives List of related manuals Drive manuals and guides Recycling instructions and environmental

More information

ABB industrial drives. Recycling instructions and environmental information ACS drives

ABB industrial drives. Recycling instructions and environmental information ACS drives ABB industrial drives Recycling instructions and environmental information ACS880-0 drives List of related manuals Drive hardware manuals and guides ACS880-0 drives recycling instructions and environmental

More information

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20

Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20 MAKING MODERN LIVING POSSIBLE Data sheet Electrically Operated Expansion Valve Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV

More information

Danfoss VLT Drives Product Overview

Danfoss VLT Drives Product Overview MAKING MODERN LIVING POSSIBLE Danfoss VLT Drives Product Overview Our products for your applications www.danfoss.com/drives Product overview VLT HVAC Drive FC 102 VLT Refrigeration Drive FC 103 VLT AQUA

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: E-12943 File No: 822.21 Job Id: 262.1-004066-3 This is to certify: That the Frequency Converter with type designation(s) FC30X series, Issued to Danfoss Drives

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302 In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, 1.1 Description Base plate assembly The back-channel cooling (in-back/out-back) kit is designed for the D5h/D6h

More information

CRITO Connection technology. Double and triple T and TCC section busbars

CRITO Connection technology. Double and triple T and TCC section busbars Centre feed unit 5 Centre feed unit Centre feed unit 5 Centre feed unit up to 4000 A combines the advantages of high short-circuit capacity, drill-free mounting, brace terminal technology and clearly structured

More information

5. Installation on Pedestal - IP 21 / IP 54 Units 43

5. Installation on Pedestal - IP 21 / IP 54 Units 43 Contents Contents 1. General Information 3 2. Preinstallation 7 Planning the Installation Site 7 Receiving the Frequency Converter 7 Transportation and Unpacking 7 Lifting 8 Shipping Weights and Dimensions

More information

Elcometer Payne Permeability Cup. Operating Instructions

Elcometer Payne Permeability Cup. Operating Instructions Elcometer 5100 English Payne Permeability Cup Operating Instructions English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2008. All rights

More information

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation?

A brief guide for identification of non-compliant construction machinery. Is this. Compactor / Roller compliant with European legislation? A brief guide for identification of non-compliant construction machinery Is this Compactor / Roller compliant with European legislation? Introduction Construction equipment placed on the EU market for

More information

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1 HANDBOOK Ed. 2017 1 CHAPTER 5 NORMALLY-CLOSED FOR REFRIGERATION PLANTS THAT USE HC REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter have been developed by Castel for all those refrigeration

More information

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft Certificate No: TAE000008A Revision No: 2 This is to certify: That the Frequency Converter with type designation(s) FC102 series, Issued to Danfoss Drives A/S GRAASTEN, Denmark is found to comply with

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

ABB Drives. Recycling instructions and environmental information ACS500 product family

ABB Drives. Recycling instructions and environmental information ACS500 product family ABB Drives Recycling instructions and environmental information ACS500 product family List of related manuals Drive hardware manuals and guides ACS500 recycling instructions and environmental information

More information

VLT AutomationDrive FC Pulse Instruction Manual VLT AutomationDrive FC 300

VLT AutomationDrive FC Pulse Instruction Manual VLT AutomationDrive FC 300 MAKING MODERN LIVING POSSIBLE VLT AutomationDrive FC 300 12-Pulse Instruction Manual VLT AutomationDrive FC 300 Contents Contents 1 How to Read the Instruction Manual 1-1 1.1.2 Abbreviations 1-2 2 Safety

More information

Liebert. FP 50Z kva

Liebert. FP 50Z kva Liebert FP 50Z 5 250 kva Enabling Tomorrow s CRITICAL EDGE INFRASTRUCTURE We helped some of the largest names in the industry bring new capacity online faster and at a lower cost when search and social

More information

XLPE Insulated 1100V. Grade. Aluminium & Copper, Power & Control, Armoured & Unamoured Cables. As per IS : 7098

XLPE Insulated 1100V. Grade. Aluminium & Copper, Power & Control, Armoured & Unamoured Cables. As per IS : 7098 XLPE Insulated 1100V. Grade. Aluminium & Copper, Power & Control, Armoured & Unamoured. As per IS : 7098 SINGLE CORE Armoured Aluminium (A2XWaY/A2XFaY) & Copper (2XWaY/2XFaY) 1100 V. Grade. No. Cores &

More information

ABB general purpose drives. Recycling instructions and environmental information ACS480 drives

ABB general purpose drives. Recycling instructions and environmental information ACS480 drives ABB general purpose drives Recycling instructions and environmental information ACS480 drives List of related manuals Drive manuals and guides ACS480 drives recycling instructions and environmental information

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 01/2016 Danfoss VUIGB202 1 2 Danfoss Energy Meters 2016.01 VUIGB202 Contents 1. Inside the box... 4 2. Installation..............................................................................

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Electric Expansion Valve Type AKVO 10

Electric Expansion Valve Type AKVO 10 Data sheet Electric Expansion Valve Type AKVO 10 AKVO 10 is an electrically operated expansion valve designed for refrigeration plant. AKVO 10 has an internal filter. The AKVO 10 range covers a capacity

More information

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data For more information please call 1-800-Belden1 See Put-ups and Colors Description: FiberExpress Patch Panels in rack and wall mount with Splice Tray and SUITABLE APPLICATIONS: Suitable Applications OUTLET

More information

CENTRE FEED UNIT UP TO 4000A. Safety

CENTRE FEED UNIT UP TO 4000A. Safety CENTRE FEED UNIT UP TO 000A Safety Centre feed unit New TCC section busbar: Connection options with CRITO PowerClip and CRITO ProfiClip, and terminal studs (screw in c-slot). 1-pole, side busbar support

More information

350 US$ saved for a single warranty claim that is why customers. Protect market reputation Minimise warranty costs.

350 US$ saved for a single warranty claim that is why customers. Protect market reputation Minimise warranty costs. Protect market reputation Minimise warranty costs A pressure transmitter overview 35 US$ saved for a single warranty claim that is why customers chose Danfoss pressure transmitters. www.danfoss.com/ia

More information

Manual No: Revision: F. Mag Probe Assembly Manual

Manual No: Revision: F. Mag Probe Assembly Manual Manual No: 576013-730 Revision: F Mag Probe Assembly Manual Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

3 Internal Frequency Converter Operation 43

3 Internal Frequency Converter Operation 43 High Power Service Manual for VLT FC Series Contents Contents 1 Introduction 11 Purpose 11 VLT FC Product Overview 11 For Your Safety 11 Electrostatic Discharge (ESD) 12 Frame Size Definitions 12 Tools

More information

Price List Water, Wastewater, and Irrigation Effective October 2012

Price List Water, Wastewater, and Irrigation Effective October 2012 MAKING MODERN LIVING POSSIBLE Price List Water, Wastewater, and Irrigation Effective October 2012 VLT AQUA Drive Contents VLT AQUA Drives... 3 VLT AQUA Drive Panels...16 VLT High Power Drives...20 VLT

More information

Electric expansion valves Types AKVA 10, 15 & 20

Electric expansion valves Types AKVA 10, 15 & 20 Data sheet Electric expansion valves Types AKVA 10, 15 & 20 AKVA are electric expansion valves designed for ammonia refrigerating plant. The AKVA valves are normally controlled by a controller from Danfoss

More information

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test

Report On Sequence IVB Evaluation Version. Conducted For. NR = Non-reference oil test RO = Reference oil test Report On Evaluation Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Nonreference oil) and shall not be used for multiple test acceptance

More information

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications

SonoSensor 30 Ultrasonic flow meter for heating and cooling applications Installation & User Guide SonoSensor 30 Ultrasonic flow meter for heating and cooling applications 03/2017 Danfoss VDIGK202 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please

More information

ABB MACHINERY DRIVES ACS380 drives Recycling instructions and environmental information

ABB MACHINERY DRIVES ACS380 drives Recycling instructions and environmental information ABB MACHINERY DRIVES ACS380 drives Recycling instructions and environmental information List of related manuals Drive hardware manuals and guides ACS380 drives recycling instructions and environmental

More information

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft Certificate No: TAE000008C Revision No: 2 This is to certify: That the Frequency Converter with type designation(s) FC-302 series, Issued to Danfoss Drives A/S GRAASTEN, Denmark is found to comply with

More information

ATEX instruction APP S 674 pumps APP S , APP S and APP S

ATEX instruction APP S 674 pumps APP S , APP S and APP S MAKING MODERN LIVING POSSIBLE Instruction APP S 674 2.0-3.5, APP S 674 5.1-9.0 and APP S 674 21-38 ro-solutions.com Table of Contents 1. General information....2 2. Common demands for Category 2 and 3

More information

CENTRAL ISSUING OFFICE (CIO) PROCEDURE FOR THE ACCEPTANCE OF NEW LOCAL ISSUING OFFICES

CENTRAL ISSUING OFFICE (CIO) PROCEDURE FOR THE ACCEPTANCE OF NEW LOCAL ISSUING OFFICES 1 CENTRAL ISSUING OFFICE (CIO) PROCEDURE FOR THE ACCEPTANCE OF NEW LOCAL ISSUING OFFICES 2016-06-29 VERSION 1.0 2 3 4 5 TABLE OF CONTENTS 1 INTRODUCTION... 5 2 PROCEDURE FOR THE CREATION OF A NEW LOCAL

More information

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

98% VLT High Power Drives to fit your application. energy efficiency. drives.danfoss.com. Selection Guide

98% VLT High Power Drives to fit your application. energy efficiency. drives.danfoss.com. Selection Guide Selection Guide VLT High Power Drives to fit your application 98% energy efficiency Save energy and money with >98% efficient VLT drives drives.danfoss.com 2 Contents Easy-to-own AC drives with application-specific

More information

Temperature sensors types MBT 153, MBT 120 and MBT 3260

Temperature sensors types MBT 153, MBT 120 and MBT 3260 Data sheet Temperature sensors types MBT 153, MBT 120 and MBT 3260 Universal cable temperature sensor Type MBT 153 For temperature measurement and regulation where reliable, robust and accurate equipment

More information

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems

your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems your comfort. our world. Biddle air curtains For connection to Daikin Sky Air Systems CityM-DK-F Air curtains for Sky Air Biddle City air curtains are the ideal solution for retailers and consultants to

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive

More information

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1 HANDBOOK Ed. 2017 VS-ED 01/2017 - ENG 1 2 VS-ED 01/2017 - ENG TABLE OF CONTENTS CHAPTER 1 CHAPTER 2 CHAPTER 3 CHAPTER 4 CHAPTER 5 CHAPTER 6 CHAPTER 7 CHAPTER 8 CHAPTER 9 CHAPTER 10 CHAPTER 11 CHAPTER 12

More information

standards based cylinder DNCI Operating instructions e [ ]

standards based cylinder DNCI Operating instructions e [ ] standards based cylinder DNCI en Operating instructions 8072823 2017-05e [8072825] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which

More information

SonoSelect and SonoSafe energy meters

SonoSelect and SonoSafe energy meters energy meters 03/2017 Danfoss VUIGB602 www.heating.danfoss.com 1 Note! To ensure latest version of declaration, please visit danfoss.com. 2 Danfoss Energy Meters 2017.03 VUIGB702 Contents 1. Inside the

More information

APP pumps APP(W) Disassembling and assembling

APP pumps APP(W) Disassembling and assembling Service guide APP pumps APP(W) 5.1-10.2 Disassembling and assembling hpp.danfoss.com Table of Contents Contents Introduction...2 1. Disassembling the pump...3 2. Assembling the pump...5 3. Disassembling

More information

Operating Instructions VLT AutomationDrive FC 302

Operating Instructions VLT AutomationDrive FC 302 MAKING MODERN LIVING POSSIBLE Operating Instructions VLT AutomationDrive FC 302 90 1200 kw www.danfoss.com/drives Contents Contents 1 Introduction 4 1.1 How to Read these Operating Instructions 4 1.1.1

More information

INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100

INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 TRUCKS FOOD OFFSHORE FISH SAMSON LIQUID RING VACUUM PUMPS INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 DOC3700C INDUSTRY GAMMA UNITS 2 CONTENTS 1

More information

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English Modbus Interface DIII EKMBDXA7V1 Modbus Interface DIII English 379 mm 0 C 100 mm 50 mm 50 mm 40 mm 87 mm 300 mm IP X0 50 mm 60 C 365 mm 124 mm Max. 100 mm Min. 1 2 3 1 www.daikineurope.com/support-and-manuals/product-information/

More information

Spare Parts List. Edition 10/07

Spare Parts List. Edition 10/07 Spare Parts List Edition 10/07 Spare Parts List for the following products Table of Contents PRODUCT NUMBER CATALOG NUMBER PRODUCT DESCRIPTION 103957 BP-IP300 BRADY IP PRINTER - 300DPI STANDARD 103958

More information

Post evolve Series. Installation Manual

Post evolve Series. Installation Manual Post evolve Series Installation Manual Post evolve Smart Series Installation Manual COPYRIGHT INFORMATION This document is copyrighted, 2017 by Circontrol, S.A. All rights are reserved. Circontrol, S.A.

More information

ABB Drives. Recycling instructions and environmental information ACS550 and ACH550 product family

ABB Drives. Recycling instructions and environmental information ACS550 and ACH550 product family ABB Drives Recycling instructions and environmental information ACS550 and ACH550 product family List of related manuals Drive hardware manuals and guides ACS550 and ACH550 recycling instructions and environmental

More information

ILLUSTRATED PARTS BREAKDOWN - IPB Bill of Materials - BOM

ILLUSTRATED PARTS BREAKDOWN - IPB Bill of Materials - BOM ILLUSTRATED PARTS BREAKDOWN - IPB Bill of Materials - BOM 1834 Surface Mount 1834-0 Stainless Steel, 1834-081 Gold Plated 10 2600-735 1 EA Hole Plug Blk Nylon.2 dia. 15 1814-004 1 EA Cover Plastic Light

More information

Chapter 1. Connectors & Fittings for Railways

Chapter 1. Connectors & Fittings for Railways Chapter Connectors & Fittings for Railways Current Carrying Catenary Dropper Component N Messenger Bz Cable length from L Component N 3 Component N 2 Contact Wire SNCF approved This dropper provides a

More information

Installation Guide VLT Parallel Drive Modules

Installation Guide VLT Parallel Drive Modules ENGINEERING TOMORROW Installation Guide VLT Parallel Drive Modules 50 00 kw vlt-drives.danfoss.com Contents Installation Guide Contents Introduction 4. Purpose of the Manual 4. Additional Resources 4.3

More information

Environmental Declaration Product family MNS ABB Low Voltage Systems

Environmental Declaration Product family MNS ABB Low Voltage Systems Environmental Declaration Product family MNS ABB Low Voltage Systems ABB Main manufacturers: ABB Schaltanlagentechnik GmbH DE 68526 LADENBURG, Germany Tel: +49 (0)6203 71 0 Fax: +49 (0)6203 71 2351 ABB

More information

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work Technical Data Sheet Uninterruptible Power Supply TLESM_030-180_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91

More information

Batteries shipped by Road

Batteries shipped by Road Batteries shipped by Road Lithium Batteries Extract from the Road Code ADG 7.5 See next page for special provisions and packing instructions (Note: LP = Large Packages over 400 Kg. These Packing Instructions

More information

Post evolve Series. Installation Manual

Post evolve Series. Installation Manual Post evolve Series Installation Manual Post evolve Series Installation Manual COPYRIGHT INFORMATION This document is copyrighted, 2017 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves

More information

WMVE Series Rugged Wall Mounts

WMVE Series Rugged Wall Mounts I N S T A L L A T I O N WMVE Series Rugged Wall Mounts C2253M-B (1/14) Important Notices IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow

More information

BOXES CSA 1. D BOXES CSA 1 DIMENSIONS

BOXES CSA 1. D BOXES CSA 1 DIMENSIONS STEEL ALUMINUM indoor Indoor D BOXES CSA 1. D BOXES CSA 1 DIMENSIONS Ship Wt. List DIMENSIONS Ship Wt. List CAT. NO. H W D (LBS.) Price CAT. NO. H W D (LBS.) Price D-S-060603 6 6 3 2 11.80 D-A-060603 6

More information

HFK. Balanced Port Thermo Expansion Valve Kits. Save Inventory $ and Valuable Truck Stock Space

HFK. Balanced Port Thermo Expansion Valve Kits. Save Inventory $ and Valuable Truck Stock Space HFK Balanced Port Thermo Expansion Valve Kits Save Inventory $ and Valuable Truck Stock Space Features and Benefits Features of the high performance HF valve now available with interchangeable valve bodies,

More information

Earthing Principles. Symmetra PX 250/500 kw

Earthing Principles. Symmetra PX 250/500 kw Earthing Principles Symmetra PX 250/500 kw Table of Contents Earthing Principles... 1 Decoding the Earthing Types... 1 TN Systems... 2 Characteristics... 2 Reference to IEC/EN 60364-4-41 413.1.3... 2

More information

THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT

THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT Replacement Instructions WPLLD Transducer Replacement Instructions Manual Number 577013-710, Revision A WARNING THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A

More information

Elcometer 415. Coating Thickness Gauge. Operating Instructions

Elcometer 415. Coating Thickness Gauge. Operating Instructions Elcometer 415 English Coating Thickness Gauge Operating Instructions R English Equipment described in these instructions is covered by the following Patents: FNF UK Patent No: GB2306009B, FNF US Patent

More information

ABB Drives. Recycling instructions and environmental information SAMI STAR product family

ABB Drives. Recycling instructions and environmental information SAMI STAR product family ABB Drives Recycling instructions and environmental information SAMI STAR product family List of related manuals Drive hardware manuals and guides SAMI STAR recycling instructions and environmental information

More information

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE A WATER-COOLED LIQUID CHILLERS HERMETIC SCROLL RENEWAL PARTS Supercedes: 150.7-RP1 (709) Form: 150.7-RP1 (810) MODELS YCRL0064, 0074, 0084, 0096, 0118, 016, 0156, 0177, 0198, 000, 030, 060, 0300, 0345, 0385,

More information

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for APP 0.6-10.2 / PAH 2-100 PAHT G 2-90 / PAH 25-80 Tech danfoss.high-pressurepumps.com Table of Contents 1. Common demands for Category 2 and

More information

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V1.2.1 ( ) Harmonized European Standard (Telecommunications series) EN 301 783-2 V1.2.1 (2010-07) Harmonized European Standard (Telecommunications series) Electromagnetic compatibility and Radio spectrum Matters (ERM); Land Mobile Service; Commercially available amateur

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

File In/With: N/A. Equipment Affected: TXV Standard with ETRE (old) used as an option on some units. Brine units use TXV and SOL.

File In/With: N/A. Equipment Affected: TXV Standard with ETRE (old) used as an option on some units. Brine units use TXV and SOL. Service Information File In/With: N/A Equipment Affected: Supersedes SI0273 (1216) YCAL / YLAA / YCWS / YCAS / YCWL / YCRL Where TXV's are used SI0273 Rev 417 GENERAL There has been some confusion on which

More information

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1

HANDBOOK SOLENOID VALVES. Ed SOLENOID VALVES VS-ED 01/ ENG 1 HANDBOOK Ed. 2017 VS-ED 01/2017 - ENG 1 CHAPTER 3 NORMALLY-CLOSED PULSE FOR REFRIGERATION PLANTS THAT USE HFC OR HFO REFRIGERANTS APPLICATION The solenoid valves illustrated in this chapter are designed

More information

Grundfos Home Booster

Grundfos Home Booster GRUNDFOS DATA BOOKLET Grundfos Home Booster UPA 15-9, UPA 15-12, UPA 15-16, UPA 12 5/6 Hz Grundfos Home Booster Table of contents 1. Product description 3 Applications..................................................................................

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 ISO 9001 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Run times: - SQM1...

More information

IMILV01 Carry out routine light vehicle maintenance

IMILV01 Carry out routine light vehicle maintenance IMILV01 Carry out routine light vehicle maintenance Overview This NOS is about conducting routine maintenance, adjustment and replacement activities as part of the periodic servicing of light vehicles.

More information

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011) Adam Equipment WBW & WBW-M SERIES (P.N. 3036610540, Revision A2, November 2011) Adam Equipment strives to be more environmentally focused and uses recycled materials and environmentally friendly packaging

More information

Technical Data Sheet :

Technical Data Sheet : Technical Data Sheet : Die-cast Aluminium Enclosure Material: AI Si 12, as per DIN EN 1706 Components: Fastening threads M4 / M6 in the enclosure bottom. Ingress protection: IP66 / IP67 / IP68 as per IEC

More information

Rittling Econoline Enclosures

Rittling Econoline Enclosures Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econoline Enclosures Submittal Data, English Language, IP Units Submittal data Project Job number Architect Performance

More information

National Certificate in Motor Industry (Coachbuilding) with strands in Passenger Service Vehicles, Commercial Vehicles, and Motor Homes and Caravans

National Certificate in Motor Industry (Coachbuilding) with strands in Passenger Service Vehicles, Commercial Vehicles, and Motor Homes and Caravans NZQF NQ Ref 0413 Version 6 Page 1 of 13 National Certificate in Motor Industry (Coachbuilding) with strands in Passenger Service Vehicles, Commercial Vehicles, and Motor Homes and Caravans Level 4 Credits

More information

Vane pump upgrade kit 180F4161 isave 21 ERD Disassembling and assembling

Vane pump upgrade kit 180F4161 isave 21 ERD Disassembling and assembling Service guide Vane pump upgrade kit 180F4161 isave 21 ERD Disassembling and assembling hpp.danfoss.com Table of Contents Contents 1. General Introduction...2 1.1 Parts included in the vane pump upgrade

More information

HDF3-A Type 7 HDF4-A Type 3

HDF3-A Type 7 HDF4-A Type 3 Quality System ISO 9001 Certified Environmental Management System ISO 14001 Certified See pages 16 for ATEX ratings Heavy Duty Flap Valve HDF3-A Type 7 HDF4-A Type 3 Air-Operated Double Pump ENGINEERING,

More information

FMU4X, FMC4X FMU4Z, FMC4Z

FMU4X, FMC4X FMU4Z, FMC4Z HORIZONTAL FAN COILS FMU4Z and FMC4Z 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2, 2 1/2, and 3 Tons Horizontal application only Accessory field installed electric heat kits available in 3, 5,

More information

Fitting Instructions. Jacobsen TR3 - LMAC378 Backlap Kit G-GB (rev.0)

Fitting Instructions. Jacobsen TR3 - LMAC378 Backlap Kit G-GB (rev.0) 25003G-GB (rev.0) Fitting Instructions Jacobsen TR3 - LMAC378 Backlap Kit GB United Kingdom RJL 100 July 2010 WARNING: If incorrectly used this machine can cause severe injury. Those who use and maintain

More information

NCSA 20plus Service Manual

NCSA 20plus Service Manual Adam Equipment NCSA 20plus Service Manual (P.N. 7.00.6.6.0247- Revision A - August 2012) Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS...1 1.1 KEY AND PANEL DESCRIPTION...2 2.0 OPERATION...3 2.1

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES 17 SOLENOID VALVES FO EFIGEATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC,

More information

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS ENERGY SERVICES ENGINEERING 840 Northgate Drive Telephone (509) 942-7403 Fax (509) 942-7405 P.O. Box 190 Richland, WA 99352 www.ci.richland.wa.us SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

More information

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Solenoid valves Type EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING. Technical leaflet Solenoid valves EVR 2 40 NC/ NO REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 DKRCCPDBB0A202-520H275 Danfoss A/S, 0-2006 Contents Page Introduction.......................................................................................

More information

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz Specification sheet Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz Description This Cummins Power Generation commercial generator set is a fully integrated power generation

More information

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For

Mack T-11 D EGR Engine Oil Test. Report Packet Version No. Conducted For Report Packet Version No. Conducted For V = I = N = Valid; The reference oil/non-reference oil was evaluated in accordance with the test procedure. Invalid; The reference oil/non-reference oil was not

More information