THE RIGHT SOLUTION FOR EVERY APPLICATION
|
|
- Hope Sherman
- 5 years ago
- Views:
Transcription
1 VFD ABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLIATION Products Added VFD Lean TR VFD Dual TR Servo VFD ombo DS VFD XLPE TR VFD XLPE 2KV TR Also Included! FLEXIBLE ONTROL ONTINUOUS FLEX SILIONE TORSION TRAY VFD DATA SERVO MOTOR EUROPEAN STYLE BUS/AT HALOGEN-FREE REELING SPEIAL USTOM
2 VFD Lean TR: Reduced d OD,, oil rresistant and flexible VFD cable VFD Lean TR is an extremely exible and oil resistant VFD cable. It is designed to perform in VFD applications where increases in voltage can occur due to spikes, harmonics, in-rush current and wave re tion. VFD Lean TR has a foil and tinned copper braid shield for 100% protection against EMI and RFI. (UL) T-ER 90 UL MTW 600V/1000V TEHNIAL DATA: Voltage: UL/c(UL): 600 V UR/SA AWM: 1000 V UL WTT: 1000 V Temperature: UR-AWM up to UL/(UL)/ SA AWM up to static haracteristics: UL / c(ul) FT4 olor code: black # d conductors with ONSTRUTION: onductor: lass 5 tinned copper stranding Insulation: specially formulated PV/nylon black PV Oil resistant meeting Oil Res 1 Reduced OD for easier installation Tinned copper class 5 stranding for improved exibility UL T-ER, UL MTW, UL WTT & UR AWM c(ul) I, SA AWM FT 4 RoHS & E able weight Amperage Maximum Horse Power Ra ng* AWG/ inch mm lbs/m V 460V 575V /4c /4c /4c /4c / /4c /4c /4c /4c /4c EM-2 grounding connector EM-4 grounding connector NPT PG Metric NPT PG Metric EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-16 EM2-25 EN4-1/2 EP4-16 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-1 EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM4-50 Table shows recommended cable glands. Other thread sizes may be available. Refer to EM gland pages at the end of this brochure. Allowable ampacities are based on no more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of 30 (2011 NE Table (B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recommended for based on horse power (HP) and the full load current (FL) x 125% per NE Art (A). Amperes (FL) were determined from NE Art
3 VFD VFD XLPE XLPE TR: TR: XLPE insulated, oil oil resistant and flexible VFD cable VFD XLPE TR has XLPE insulation for improved capacitance for longer installations and is extremely flexible and oil resistant. It is designed to perform in VFD applications where increases in voltage can occur, such as spikes in harmonics, in-rush current and wave reflection. VFD XLPE TR has a foil and tinned copper braid shield for 100% protection against EMI and RFI. (UL) T-ER 90 DRY/WET 600V/1000V TEHNIAL DATA: Voltage: UL/c(UL): 600 V SA AWM: 1000 V UL WTT: 1000 V Temperature: UL/c(UL)/ SA AWM up to static /105 0 haracteristics: UL / (UL) FT4 olor code: black # d conductors with ONSTRUTION: onductor: lass K tinned copper stranding Insulation: specially formulated XLPE black PV XLPE insulation for excellent capacitance values Oil resistant meeting Oil Res 1 & 2 Tinned copper class K stranding for improved exibility UL T-ER, UL MTW, UL WTT & UL Flexible Motor Supply able c(ul) I-T, SAAWM FT 4 RoHS & E able weight e Maximum Horse Power Ra ng* AWG/ inch mm lbs/ V 460V 575V /4c /4c /4c / /4c /4c /4c /4c /4c EM-2 EM connector EM-4 EM connector NPT PG Metric NPT PG Metric EP2-16 EM2-25 EN4-1/2 EP4-16 EM EN2-3/4 EP2-16 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-1 EP4-29 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-1 EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM4-50 Table shows recommended cable glands. Other thread sizes may be available. Refer to EM gland pages at the end of this brochure. Allowable ampacities are based on not more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of 30 (2011 NE Table (B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recommended for based on horse power (HP) and the full load current (FL) x 125% per NE Art (A). Amperes (FL) were determined from NE Art
4 VFD ombo DS: Flexible VFD cable with 1 or 2 pairs for brake Servo VFD ombo DS is a flexible VFD cable with 1 or 2 pairs for a brake or temperature sensor when they are part of the motor. The pairs are individually shielded with a drain wire. Servo VFD ombo DS also has a foil and tinned copper braid shield for 100% protection against EMI and RFI. (UL) T-ER 90 UL MTW 600V/1000V TEHNIAL DATA: Voltage: UL/c(UL): 600 V UR/SA AWM: 1000 V UL WTT: 1000 V Temperature: UR-AWM up to UL/c(UL)/ SA AWM up to static haracteristics: UL / c(ul) FT4 olor code: black # d conductors with pairs: numbered 5/6 & 7/8 ONSTRUTION: onductor: lass 5 tinned copper stranding Insulation: specially formulated PV/nylon black PV Shielded pair(s) for a brake or temperature sensor all in one cable Oil resistant meeting Oil Res 1 Tinned copper class 5 stranding for improved flexibility UL T-ER, UL MTW, UL WTT & UR AWM c(ul) I, SA AWM FT 4 RoHS & E able Maximum Horse Power Amperage weight Rating* AWG/ Pair inch mm lbs/mft V 460V 575V /4c 14/1pr /4c 18/2pr / /4c 18/1pr /4c 14/1pr /4c 18/2pr /4c 18/1pr /4c 14/1pr /4c 18/2pr / /4c 14/1pr / /4c 14/1pr EM-2 EM connector EM-4 EM connector NPT PG Metric NPT PG Metric EN2-3/4 EP2-16 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-32 EN4-1 EP4-29 EM EP2-16 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-3/4 EP2-21 EM2-25 EN4-1 EP4-29 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM4-32 Table shows recommended cable glands. Other thread sizes may be available. Refer to EM gland pages at the end of this brochure. Allowable ampacities are based on three current carrying conductors plus pairs in a raceway, cable, or direct buried and an ambient temperature of 30 (2011 NE Table (B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recommended for based on horse power (HP) and the full load current (FL) x 125% per NE Art (A). Amperes (FL) were determined from NE Art Other dimensions available upon request.
5 VFD ombo XLPE: XLPE insulation plus shielded pair for brake VFD ombo XLPE has XLPE insulation for improved capacitance for longer installations. It also has a shielded pair for temperature sensor or brake. VFD ombo XLPE is flexible and very oil resistant and has an overall foil and braid shield for 100% protection against EMI and RFI. (UL) T-ER 90 UL MTW 600V/1000V TEHNIAL DATA: Voltage: UL/c(UL): 600 V UR/SA AWM: 1000 V UL WTT: 1000 V Temperature: UL/c(UL)/ SA AWM up to static /105 0 haracteristics: olor code: UL / c(ul) FT4 black # d conductors with ONSTRUTION: onductor: lass K tinned copper stranding Insulation: specially formulated XLPE black PV XLPE insulation for excellent capacitance values Shielded pair for temperature sensor or brake Oil resistant meeting Oil Res 1 & 2 UL T-ER, UL MTW, UL WTT & UL Flexible Motor Supply able c(ul) I-T, SA AWM FT 4 RoHS & E able Maximum Horse Amperage weight Power Rating* AWG/ Pair inch mm lbs/mft V 460V 575V /4c 18/1pr /4c 18/1pr /4c 14/1pr /4c 18/1pr /4c 14/1pr /4c 14/1pr / /4c 14/1pr /4c 14/1pr /4c 14/1pr /4c 14/1pr EM-2 EM connector EM-4 EM connector NPT PG Metric NPT PG Metric EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-1 EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM4-50 Table shows recommended cable glands. Other thread sizes may be available. Refer to EM gland pages at the end of this brochure. Allowable ampacities are based on not more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of 30 (2011 NE Table (B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recommended for based on horse power (HP) and the full load current (FL) x 125% per NE Art (A). Amperes (FL) were determined from N E Art
6 VFD Dual TR: Rugged, oil resistant and flexible VFD cable VFD Dual TR is a flexible VFD cable with an inner jacket for more rugged applications. The inner jacket also helps impede capacitive attraction between the shield and conductors. VFD Dual TR has a foil and tinned copper braid shield for 100% protection against EMI and RFI. c(ul) I 90 FT4 SA AWM I/II A/B V TEHNIAL DATA: Voltage: UL/c(UL): 1000 V UR/SA AWM: 1000 V UL WTT: Temperature: UR-AWM up to +105 UL/(UL)/ SA AWM up to static haracteristics: UL / c(ul) FT4 olor code: black # d conductors with 0 ONSTRUTION: onductor: lass 5 tinned copper stranding Insulation: specially formulated PV/nylon black PV Oil resistant meeting Oil Res 1 Inner jacket for rugid applications Tinned copper class 5 stranding for improved flexibility UL T-ER, UL MTW, UL WTT & UR AWM c(ul) I, SA AWM FT 4 RoHS & E able weight Amperage Maximum Horse Power Rating* AWG/ inch mm lbs/mft V 460V 575V /4c /4c /4c / /4c /4c /4c /4c /4c EM-2 grounding connector EM-4 grounding connector NPT PG Metric NPT PG Metric EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-16 EM2-25 EN4-1/2 EP4-16 EM EP2-16 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-1 EP4-29 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM4-50 Table shows recommended cable glands. Other thread sizes may be available. Refer to EM gland pages at the end of this brochure. Allowable ampacities are based on no more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of 30 (2011 NE Table (B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recommended for based on horse power (HP) and the full load current (FL) x 125% per NE Art (A). Amperes (FL) were determined from NE Art
7 VFD Lean Auto TR: ontinuous flex and oil resistant VFD cable (UL) T-ER 90 UL MTW 600V/1000V TEHNIAL DATA: Voltage: UL/c(UL): UR/SA AWM: UL WTT: 1000 V Temperature: UR-AWM up to haracteristics: olor code: UL/(UL)/ SA AWM static 600 V 1000 V up to UL / c(ul) FT4 black # d conductors with ONSTRUTION: onductor: lass 6 tinned copper stranding Insulation: specially formulated PV/nylon black PV Oil resistant meeting Oil Res 1 Extra fine stranding for continuous flex applications UL T-ER, UL MTW, UL WTT & UR AWM c(ul) I, SA AWM FT 4 RoHS & E able weight Amperage Maximum Horse Power Rating* AWG/ inch mm lbs/mft V 460V 575V /4c /4c /4c / /4c /4c /4c /4c /4c VFD Symmetrical XLPE TR: Flexible VFD cable with 3 symmetrical grounds (UL) T-ER 90 UL MTW 600V/1000V TEHNIAL DATA: Voltage: UL/c(UL): UR/SA AWM: UL WTT: 600 V 1000 V 1000 V Temperature: UL/(UL)/ SA AWM up to +105 static haracteristics: UL / c(ul) FT4 olor code: black # d conductors with 0 ONSTRUTION: onductor: lass K tinned copper stranding Insulation: specially formulated XLPE black PV XLPE insulation for excellent capacitance values Oil resistant meeting Oil Res 1 & 2 3 symmetrical grounds for M Tinned lass K stranding for improved flexibilty UL T-ER, UL MTW, UL WTT and UL Flexible Motor Supply able c(ul) I-T, SA AWM FT 4 RoHS & E able weight Amperage Maximum Horse Power Rating* AWG/ Ground inch mm lbs/mft V 460V 575V /3c 3 x /3c 3 x / /3c 3 x /3c 3 x /3c 3 x /3c 3 x /3c 3 x
8 VFD XLPE 2KV TR: Shielded VFD cable rated for 2 KV with 3 symmetrical grounds VFD XLPE 2KV TR has an XLPE insulation for improved capacitance for longer installations. It has 3-symmetrical grounds to perform in VFD applications where increases in voltage such as ommon Mode urrent (M) can occur. VFD XLPE 2KV TR has a copper tape shield for 100% protection against EMI and RFI. 4/0 AWG 3 TYPE T-ER RHH OR RHW-2 DRS TEHNIAL DATA: Voltage: UL: Temperature: UL: static haracteristics: UL FT4 olor code: 2000V up to black # d conductors with ONSTRUTION: onductor: lass B bare copper stranding Insulation: specially formulated XLPE Screen: 5 mil copper tape with 50% overlap black PV XLPE insulation for excellent capacitance values 3 symmetrical grounds for better common mode current flow opper tape shield (50% overlap) for premium EMI & RFI protection UL T-ER RoHS able weight Amperage Maximum Horse Power Rating* AWG/ Ground inch mm lbs/mft V 460V 575V /3c 3 x /0-3c 3 x /0-3c 3 x /0-3c 3 x /0-3c 3 x c 3 x c 3 x c 3 x NPT EM-2 EM connector PG Metric NPT EM-2 EM connector PG Metric EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM EP2-48 EM2-63 EN4-2 EP4-48 EM EP2-48 EM2-63 EN4-2 EP4-48 EM EM EM Table shows recommended cable glands. Other thread sizes may be available. Refer to EM gland pages at the end of this brochure. Allowable ampacities are based on not more than three current carrying conductors in a raceway, cable, or direct buried and an ambient temperature of 30 (2011 NE Table (B)(16)) * Maximum Horse Power rating represents the largest HP motor the AWG is recommended for based on horse power (HP) and the full load current (FL) x 125% per NE Art (A). Amperes (FL) were determined from N E Art ord Grips available. See back page for more information.
9 VFD Termination Kits: 14 AWG to 500 kcmil VFD cables VFD Termination Kits are used to ground the shield of VFD cables to a metal enclosure and motor housing. It is an effective way to remove noise associated with VFD motors and drives. Improve the effectiveness by also using a SAB EM grounding gland where the cable enters the enclosure and motor housing. Kit VFD GRD KIT 14-1 VFD GRD KIT 1-4/0 VFD GRD KIT Kit omponents 1/4" flat Tinned copper braid 3/4" opper tape Bolt assembly (see parts below) Rubber splicing tape Low profile tie wrap 7" Metal sand paper 3" x 3" Alcohol wipes 3/4" flat Tinned copper braid 3/4" opper tape Bolt assembly (see parts below) Rubber splicing tape Low profile tie wrap 7" Metal sand paper 3" x 3" Alcohol wipes 1" flat Tinned copper braid 3/4" opper tape Bolt assembly (see parts below) Rubber splicing tape Low profile tie wrap 10" Metal sand paper 3" x 3" Alcohol wipes Quantity 2 x 3ft 2 x 1ft Installation Prep Photo 1 bag 1 roll 2 pcs 1 pc 2 pcs 2 x 3ft 2 x 2ft 1 bag 1 roll 2 pcs 1 pc 2 pcs Attach to Enclosure 2 x 3ft 2 x 2ft 1 bag Bolt assembly brass bolt 1/4"-20 x 1-1/4" 2 pcs 1 roll brass nut 1/4"-20 2 pcs 2 pcs bronze locking washer 1/4"-20 2 pcs 1 pc brass washer 1/4"-20 x 9/16" OD 2 pcs 2 pcs brass washer 1/4"-20 x 1 1/4" OD 2 pcs
10 G EM-2: EM grounding gland, Metric PG & NPT Thread EM-2 is a nickel plated brass strain relief with integral grounding springs in the gland. It has an IP 68 protection class for excellent protection against dust and water spray. EM-2 comes in metric, PG and NPT thread. Material ontact Spring lamping Insert Seal O-Ring Protection lass Temperature Range Technical Data: Brass, Nickel Plated Special opper Alloy Polyamide 6 V2 hloroprene (R) NBR IP 68-5 Bar -20 to +100 permanent -40 to +150 intermittent Flammability V2 (according to UL 94) Thread Size lamping Range Ø Shield Diameter Thread Diameter (TD) Thread Length (TL) Wrenching Flats ap (SW1) Height (H) inches mm mm mm mm (min-max) (Ø min) NPT EN2-3/8 NPT 3/ EN2-1/2 NPT 1/ EN2-3/4 NPT 3/ EN2-1 NPT PG EP2-7 PG EP2-9 PG EP2-11 PG EP2-13 PG EP2-16 PG EP2-21 PG EP2-29 PG EP2-36 PG EP2-42 PG EP2-48 PG Metric EM2-12 M12X EM2-16 M16X EM2-16 M16X EM2-20 M20X EM2-25 M25X EM2-25 M25X EM2-32 M32X EM2-32 M32X EM2-40 M40X EM2-40 M40X EM2-50 M50X EM2-50 M50X EM2-63 M63X Additional thread sizes and colors available upon request
11 G EM-4: EM grounding glandwith vibration proof grounding springs Technical Data: Material Brass, Nickel Plated ontact Spring Special opper Alloy lamping Insert Polyamide 6 V2 Seal hloroprene (R) O-Ring NBR Protection lass IP 68-5 Bar Temperature Range -20 to +100 permanent -40 to +150 intermittent Flammability V2 (according to UL 94) EM-4 is a nickel plated brass strain relief with integral grounding springs in the gland that will allow the cable to move without damage to the shield. A cable can be installed from either direction as well. It has an IP 68 protection class for excellent protection against dust and water spray. Thread Size lamping Range Ø Shield Diameter Thread Diameter (TD) Thread Length (TL) Wrenching Flats ap (SW1) Height (H) inches mm mm mm mm (min - max) (Ø min - max) NPT EN4-1/4 NPT 1/ EN4-3/8 NPT 3/ EN4-1/2 NPT 1/ EN4-1/2 NPT 1/ EN4-3/4 NPT 3/ EN4-1 NPT EN4-1 1/4 NPT 1 1/ EN4-1 1/2 NPT 1 1/ EN4-2 NPT Metric EM4-12 M12X EM4-16 M16X EM4-20 M20X EM4-20 M20X EM4-25 M25X EM4-32 M32X EM4-40 M40X EM4-50 M50X EM4-63 M63X EM4-63 M63X PG EP4-7 PG EP4-9 PG EP4-11 PG EP4-13 PG EP4-16 PG EP4-21 PG EP4-29 PG EP4-36 PG EP4-42 PG EP4-48 PG
12 Technical Information VFD Lean TR VFD XLPE TR Part Number apacitance (pf/ft) Impedance (Ohms) ord Grips Mutual Ground* Mutual Ground* EM-2 EM EP2-13 EP EP2-13 EP EP2-13 EP EP2-16 EP EP2-21 EP EP2-29 EP EP2-36 EP EP2-36 EP EP2-42 EP EP2-16 EP EP2-21 EP EP2-21 EP EP2-21 EP EP2-29 EP EP2-36 EP EP2-36 EP EP2-42 EP4-42 *for VFD Lean TR, value is conductor to screen orresponding ord Grips VFD Lean Auto TR VFD Symmetrical XLPE TR Part EM-2 grounding connector EM-4 grounding connector Number NPT PG Metric NPT PG Metric EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-13 EM2-20 EN4-1/2 EP4-13 EM EN2-1/2 EP2-16 EM2-25 EN4-1/2 EP4-16 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-1 EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM EP2-16 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-3/4 EP2-21 EM2-25 EN4-3/4 EP4-21 EM EN2-1 EP2-29 EM2-32 EN4-1 EP4-29 EM EN2-1 EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-36 EM2-40 EN4-1 1/4 EP4-36 EM EP2-42 EM2-50 EN4-1 1/2 EP4-42 EM4-50 Toll Free: Fax: co 344 Kaplan Drive, NJ c
VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS
VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS VFD Lean TR VFD Dual TR Servo VFD Combo DS VFD XLPE TR VFD XLPE 2KV TR SAB s VFD cable series has you covered from fractional to 2 HP drives suitable for industrial
More informationCable Accessories. Cord Grips QUALITY - FASTER THAN YOU THINK!
Cable Accessories Cord Grips QUALITY - FASTER THAN YOU THINK! SAB North America is an industry leader in the design and manufacturing of flexible cables and continuous flex products. For over 50 years
More informationEasier! Faster! Safer!
Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...
More informationVariable Frequency Drive (VFD) Cable Solutions
Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as
More informationTHE RIGHT SOLUTION FOR EVERY APPLICATION
CATEGORY CABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLICATION FLEXIBLE CONTROL CONTINUOUS FLEX SILICONE TORSION TRAY VFD DATA SERVO MOTOR EUROAN STYLE BUS/CAT HALOGENFREE REELING SCIAL CUSTOM
More informationÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.
Multi-listed, flexible VFD cable - screened VFD cable for fixed installation or occasional flexing with UL TC-ER. Info VFD drive and motor connections Wide application range (NFPA 70/NEC)/ compliance with
More informationGexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company
Gexol Gexol World Class World Class Mission-critical designed for safe, reliable performance in extremely hazardous operating environments Power Control Instrumentation VFD MMV Assembly Solutions The Global
More informationLUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions
USA Cable Solutions LUTZE Flexible Cable and Wire Management for Industrial Automation Control Cable Electronic Cable Actuator Sensor Cable BUS and Network Cable Motor Supply, VFD, Servo and Feedback Cable
More informationItem Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...
Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter A A 146 FRN A A 156 FRN Halogen-free wiring with improved fire performance and extended temperature range 300/500
More informationItem Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE...
Halogen-free ables E-mail: info@sab.com Web site: www.sab.com Item Description Page hapter Halogen-free single A A 146 FRN A A 156 FRN Halogen-free single conductor with improved fire performance and extended
More informationEthernet Buccaneer BUCCANEER DATA. bulgin
BUCCANEER FOR DATA bulgin Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains
More informationCABLED TWISTED PAIRS CONDUCTORS
CABLED TWISTED PAIRS CONDUCTORS NQP SERIES Twisted Pair uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete
More information0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR
TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements
PVC servo cables C-track compatible shielded Subject to technical modification 111270 Identification Type SU+M(C)P SE(4G1,0+2 (2 0,75))UL 1KV OR INK Description* INK 0653 Use/Application/Properties Application
More informationEnergy Supply Systems C-RAIL PROGRAM. KAT a-USA
Energy Supply Systems C-RAIL PROGRAM 230 KAT0230-0001a-USA C-Rails and Accessories C-Rails Catalog No. Length l Thickness s [mm] [mm] 023200-6M 6000 023200-4M 4000 023201-6M 6000 023201-4M 4000 2 1.5 6,,
More informationEthernet Buccaneer IP68 BUCCANEER FOR DATA BUCCANEER DATA
IP68 Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of Panel maintains IP68 seal to panel
More informationCABLED SINGLE CONDUCTORS
CABLED SINGLE CONDUCTORS NQ SERIES Single uctors Mil Spec, U.L. AWM Recognized Style 2464 and CSA Certified AWM II A/B GRAY PVC JACKET National Wire & Cable Corporation manufactures a complete line of
More informationVariable Frequency Drive (VFD) Cable Solutions
Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT CABLE HARNESSING made in Viersen CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT. TimSiegert-batcam / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR WIND POWER PLANT TimSiegert-batcam / Fotolia CONTENT General < Who we are......................................................................................
More informationCustomer Specification PART NO. V16110
Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. V16110 Construction Diameters (In) 1) Component 1 4 X 1 COND a)
More informationCoupling ring, screw thread provides secure cable coupling. Shielded Cat 5e coupler maintains screening. Retaining Nut
Coupling ring, screw thread provides secure cable coupling Shroud for RJ45 provides protection against damage through mis-use and positive alignment for mating of connectors Panel gasket maintains IP68
More informationItem Description Page
Cord Grips 2 Item Description Page Chapter Polyamide 6 Cord Grips CG 100 Metric Polyamide cord grip, dome cap, black or gray, metric thread.............. 3 CG 100 PG Polyamide cord grip, dome cap, black
More informationCable Glands & Accessories
Cable Glands & Accessories This catalog features ITC s extensive range of liquid-tight, strain relief cord connectors (cable glands) and accessories, including locknuts, sealing washers, plugs, etc. These
More information6000 Series Ethernet Buccaneer
Thermo-plastic version Patch Cord Flex Connector - Pur Jacket Cable PXP6037 Mates with PXP6033TP type panel mounting Overmoulded patchcords with IP rated connector Supplied with shielded RJ45 plug Single
More informationDetailed Specifications & Technical Data
Description: 20 AWG stranded (7x28).038" tinned copper conductors, polyethylene insulation, Beldfoil (100% coverage) plus a tinned copper braid shield (55% coverage), sunlight-resistant PVC jacket. Physical
More informationPROFIBUS PA Physical Media Connectivity
Cordsets Receptacles Terminating resistors Tees Field Wireables P22 P24 P30 P31 P33 Features y Cable that meets the requirements of ISA/SP 50 and PROFIBUS-PA requirements for Type A Cable y All cables
More informationTC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,
More informationIdentification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR. Part-No
PUR servo cables C-track compatible shielded Subject to technical modification 111600 Identification Type SU+M(C)P SE(4G1,5+(2 0,75)+(2 AWG22))UL 1KV OR Use/Application/Properties Application Combined
More informationCorflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3
Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation
More informationTC-RHH/RHW-2 USE-2 Copper
TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.
More informationManufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation
More information4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60
4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)
More informationOperating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.
Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series
More informationUnarmored Variable Frequency Drive (VFD) Cable Termination Guide
Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored Variable Frequency
More informationOmni Cable is a master distributor of specialty wire and cable selling
Omni Cable is a master distributor of specialty wire and cable selling company our mission is to Be the Best Vendor to our customers, to be the Best Customer to our vendors, and to be the Best Employer
More informationCF270.UL.D.
Outer jacket: Pressure extruded PUR mixture Overall shield: Bending-stable braid made of tinned copper wires Core insulation: Mechanically high-quality, especially low-capacitance TPE mixture Conductor:
More informationAutomotive Cables. The Global Cable Solutions Company
Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers
More informationMC or MV-105 Copper, TR-XLPE Insulated
MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with
More informationLoadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.
3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200
More informationOperating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.
Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series
More informationGeneral characteristics and technical data Series MCS
MOD M MC MCS VP 100 S Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and
More informationIEEE 1580 TYPE T/N CABLE
1 2 3 4 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV COMMERCIAL MARINE SHIPBOARD CABLE 90 C TEMPERATURE RATING MOISTURE, SUNLIGHT RESISTANT ABS, USCG APPROVED, UL LISTED PRODUCT CONSTRUCTION 1. CONDUCTOR
More informationIntroduction. Nexans wire and cable. Contact us for all your wire and cable needs
Introduction Nexans is one of the largest wire and cable manufacturers in the world, and in North America. In North America we manufacture in locations across the United States and Canada. We design and
More informationCable Protection Solutions for Shielding Applications CATALOG LOCK 2013 VERSION 1.0
Cable Protection Solutions for Shielding pplications LOCK CTLOG 2013 VERSION 1.0 Cable Protection Solutions for Shielding pplications Electromagnetic interference (EI) is noise that may interrupt, obstruct,
More informationCABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue
CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main
More information0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.
TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING
More informationFISCHER FREEDOM TM SERIES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More informationTC-THHN/THWN-2 Copper, PVC/Nylon Insulated
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and
More informationgrounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2
grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2 grounded in service wired to innovate www.cable.alcan.com Type XHHW-2 and Type USE-2/RHH/RHW-2 Alcan manufactures XHHW-2 and
More informationMetal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application
Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Straight, Male 45, Male 90, Male Straight, Female Straight, Cable Hose, Male Straight Swivel Fittings Ferrules for Fittings Further Accessories Applications
More informationNTC Thermistor Assemblies
FEATURES Standard and custom assemblies are available in a variety of configurations Assemblies can conveniently attach to or be an integral part of any system to monitor or control temperature No added
More informationNickel Plated Nylon Liquid Brass Liquid Tight Strain Tight Relief Strain Fittings. Features & Benefits
Features & Benefits: Nickel Plated Nylon Liquid Brass Liquid Tight Strain Tight Relief Strain Fittings Relief Fittings Features & Benefits Liquid Tight - submersible to 300 ft. - NEM 4x & 6 (IP 68 / IP
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................
More informationType MMV-WP Medium Voltage Wind Power Cable
WP Type MMVWP Medium Voltage Wind Power Cable ThreeConductor: 5kV & 5kV, % Rated 05 C Renewable Energy Cables Conductors Soft annealed flexible stranded tinned copper per IEEE 580 Table and UL 07 Insulation
More informationData sheet chainflex CF210.UL
For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic
More information14 HH EAC/CTP CE RoHS-II conform
Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand
More information127 (5) Approx (1.85) Overmold. Male Coupling Nut. Straight Micro Female 63.5 (2.5) 127 (5) Approx. Overmold Coupling Nut Straight Mini Female
KwikLink Lite Flat Drop General Quick Selection Introduction KwikLink Lite Drop Cordset with 4-wire unshielded cable. Device connection options include 5 pin mini and micro as well as flying leads. Physical
More informationBattery Cables. Wire & Cable
Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,
More informationData sheet chainflex CF886
1. Outer jacket: Pressure extruded PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Shield foil: Aluminium clad plastic foil 4. Banding: Plastic foil 5. Filling: Plastic yarns 6.
More informationCORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...
w w w. n e x a n s. u s CORFLEX Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables Introduction.... 2 Applications.... 3 CORFLEX PL 300V Instrumentation PLTC
More informationMedium Voltage Cables for PermaLife Nuclear Utility Applications
Medium Voltage Cables for PermaLife Nuclear Utility Applications The science behind our medium voltage cables. Fig. 1 Fig. 2 non-conducting stress control layer 100% production tested in accordance with
More informationK CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More informationRockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1
ontents Introduction.2 HighPower 250 A.4 4000 V 250 A 1 4 poles HighPower 550 A.10 4000 V 550 A 1 3 poles.1 Introduction Uncompromising power in clever and safe packaging. The modular high-current connector
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationOutlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.
MAX 5e Shielded Modules The shielded MAX module is the cornerstone of our category 5e screened cabling systems. This product not only meets all TIA/EIA component specifications, but also exceeds ISO/IEC
More information06. har-mik INTERFACE CONNECTORS
. INTERFACE CONNECTORS Miniature D connectors are a must in various cableto-board applications where space saving and high data transfer rates are required. For the purposes of miniaturization and speed,
More informationSection 8. Portable Cordage & Power Cable
Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene
More informationPVC motor cables unshielded
PVC motor cables unshielded LÜTZE-SILFLEX M PVC Motor connecting/energy supply cable Motor connecting cable and energy supply cable in machine and apparatus engineering, transport and conveyor technology,
More informationVariable Frequency Drive (VFD) Cable Solutions
Variable Frequency Drive (VFD) Cable Solutions Be Certain with Belden the Original Developer of High Quality Performance VFD Cable Featured Brand Belden offers the most extensive line of VFD cables, as
More informationData sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.
Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire
More informationµcom-10gb + Harsh Environment 10Gb Ethernet Micro Connectors
Harsh Environment 10Gb Ethernet Micro onnectors 15mm Description µom-series is a new range of connectors designed to address the latest trends of the industry : miniaturization and high speed, with the
More informationHigh Voltage Copper, Smooth Aluminum Shield/Sheath
High Voltage Copper, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationTHE RIGHT SOLUTION FOR EVERY APPLICATION
SAB CABLES FOR AUTOMATION THE RIGHT SOLUTION FOR EVERY APPLICATION FLEXIBLE CONTROL CONTINUOUS FLEX SILICONE TORSION TRAY VFD DATA SERVO MOTOR EUROPEAN STYLE BUS/CAT HALOGENFREE REELING SPECIAL CUSTOM
More information13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs
KRONECTION Box A 2 for up to 2 pairs Short survey of the KRONECTION Box A 2 for up to 2 pairs The KRONECTION Box A 2, which is equipped with connection contacts on the right and left, serves as a line
More informationTC-THHN/THWN-2 Copper, PVC/Nylon Insulated
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed, SR; GR; 600 V Features Standards UL Listed as TC. Jacket is rated Sunlight Resistance and Oil Resistance I. Singles meet VW-1 flame test. Meets
More informationSetting New Standards. Widest Sealing Range Maximum Strain Relief Superior Protection Rating. 94 CONTA-CLIP, Inc. (732)
Setting New Standards Widest Sealing Range Maximum Strain Relief Superior Protection Rating 94 CONTA-CLIP, Inc. (732) 564-0705 The principle benefits gland body Materials: Nickel plated brass Stainless
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................
More informationinterpower Interpower Strain Reliefs featuring products We re on the Internet! Visit our website at PANEL COMPONENTS CORPORATION
Data Sheet 148, 5/2000 Interpower Strain Reliefs new area code for our local telephone numbers will be effective July 9, 2000. The new area code is (641). Contact Panel Components Corporation at: P.O.
More informationTechnical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology
PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application
More informationcopper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)
Molded Rub ber Products 600 A 35 kv Class Separable Splices Electrical Ap pa ra tus 700-31 General Cooper Power Systems 600 A, 35 kv Class Deadbreak Separable Splices are used to splice two, three or four
More informationData sheet chainflex CF270.UL.D
For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core
More informationArt.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D
Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF280.UL.H1xx.XX.XX.D CF280.UL.H2xx.XX.XX.D 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see
More informationIndustrial, Heavy Insulated Mono-Tape. and Duo-Tape
Industrial, Heavy Insulated Mono-Tape and Duo-Tape Description: HTS/Amptek AWD and AWM Heating Tapes are Single and Double Duo-Tapes designed for use in high temperature applications. AWD and AWM Heating
More informationCables for cable carriers and reels SYSTEMS IN MOTION
Cables for cable carriers and reels SYSTEMS IN MOTION 8e/en 2016 Content PVC flatform cables (H)07VVH6-F H07VVH6-F... 4 PVC flatform cables, shielded YCFLY... 6 Neoprene flatform cables NGFLGÖU UL... 8
More informationMecklenburg County Common Code Defects
Electrical Code Defects Improper Over Current Protection Code Description 310.15 Ampacities for s Rated 0 2000 Volts. (A) General. (1) Tables or Engineering Supervision. Ampacities for conductors shall
More informationCABLE SOLUTIONS FOR MOTION CONTROL
CABLE SOLUTIONS FOR MOTION CONTROL VFD Cable Assembly Reduces Motor Failure PROBLEM: A global manufacturer of structural metal components serving automotive OEMs was experiencing problems with the cable
More informationHigh Voltage Aluminum, Smooth Aluminum Shield/Sheath
High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric
More informationD-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries
Contents Page D-Sub adapter... 40.02 Han Split Hood... 40.04 Cable entry protection with metric cable entries... 40.06 Cable entry protection with Pg cable entries... 40.08 Coding for Hoods/Housings and
More informationCONNECTIVITY SOLUTIONS. for Continuous Flex Applications. ake the right connection
CONNECTIVITY SOLUTIONS for Continuous Flex Applications ake the right connection make the right connection At Lapp Group, we understand the critical role our products play in a wide array of industries
More informationOutput Current Input Current Over Voltage. VDC VDC ma ma(typ.) ma(typ.) VDC μf % MKZI10-24S
Doc. E-92 MKZI1 SERIES D/D ONVERTER 1W, Reinforced Insulation, Railway ertified FEATURES Industrial Standard 2" 1" Package Ultra-wide Input Range 9-36VD, 18-75VD, -1VD I/O Isolation 3VA with Reinforced
More informationAccessories Cable glands
Accessories Cable glands 235 Technical data Cable glands Brass hexagon cable gland Brass sealing cable gland Material: Brass, nickel-plated Gasket: Soft rubber Protection type IP 54 Additional information:
More informationArt.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX
Overview Construction (similar to) SICK (Hiperface DSL) SEW Art.-Nr. CF220.UL.H1xx.XX.XX CF220.UL.H2xx.XX.XX 1 2 3 Example drawing L1 L2 L3 (see the chapter belonging to the cable for details) (see the
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................
More informationControl Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable
PVC Jacket (overall optional) Armor (optional) PVC Jacket Color-coded PVC/Nylon Insulation Copper ed 600/00 volts Features Maximum conductor operating temperature: 90ºC per IEEE, UL, and CSA. Meets applicable
More informationData sheet chainflex CF8821
1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Braiding made of tinned copper wires 3. Overall banding: Plastic foil 4. Core insulation: Mechanically high-quality TPE
More informationDSUBMINIATURE CONNECTOR J SERIES
D-sub J DSUMINITURE ONNETOR J SERIES Solder pot plug and receptacle SOLDER POT PLUG ND REEPTLE 01 Solder pot plug Solder pot Receptacle Features The receptacle contacts are formed by high-speed stamping
More informationDLO. Mining Cable. Mining Cable. 2 kv
11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power
More informationEPIC CIRCON M23 Series
M23 Series EPIC EPIC CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland
More information