WSAA PRODUCT APPRAISAL CERTIFICATE
|
|
- Lesley Nicholson
- 5 years ago
- Views:
Transcription
1 WSAA PRODUCT APPRAISAL CERTIFICATE Pty Ltd AWASHAFT DN 400 / DN 600 / DN 800 Polypropylene (PP) Maintenance Shafts and Chambers AWASHAFT DN 400 / DN 600 / DN 800 Polypropylene (PP) Maintenance Shafts and Chambers have been appraised for compliance with the requirements of WSA 137:2013 and WSAA Product Specifications WSA PS 341 and WSA PS 337. The scope of this appraisal applies to the AWASHAFT DN 400 / DN 600 / DN 800 Polypropylene (PP) Maintenance Shaft and Chamber units and assemblies as listed in the attached Schedules A and B. Product Category Polypropylene (PP) Maintenance Shafts and Chambers PA Number: Supplier Brand Standards PA 1508 Par1 1 Issue 4 (Certificate) Pty Ltd AWASHAFT WSA 137:2013 Industry Standard for Maintenance Shafts and Maintenance Chambers for Sewerage WSAA Product Specification WSA PS-341 Maintenance Shafts (MS) Polypropylene (PP) for Non- Pressure Applications Sewerage WSA PS-337 Maintenance Chambers (MC) Polypropylene (PP) for Non- Pressure Applications Sewerage Other Specifications Issue date 9 March 2018 Expiry date 9 March 2023 Recoendations It is recoended that WSAA members and associates, subject to any specific requirements, accept / authorise the AWASHAFT DN 400 / DN 600 / DN 800 Polypropylene (PP) Maintenance Shaft and Chamber base units and assemblies as listed in Schedule B provided in pipeline design, installation, acceptance testing and coissioning in accordance with applicable WSAA Codes and the manufacturer s requirements where specified. Disclaimer The disclaimer on Page 2 explains a number of very important limits on your ability to rely on the information in this Product Appraisal Certificate (Certificate) and the assessment criteria used to underlay it. Please read it carefully and take it into account when considering the content in this Certificate. PA 1508 Issue 3 Issue 1 Rev 0 Page 1 of 17
2 1. Disclaimer This Product Appraisal Certificate (Certificate) is issued by WSAA on the understanding that: This Certificate applies to the product(s) as submitted in Schedule A. Any changes to the product(s) either minor or major shall void this Certificate. To maintain the recoendations of this Certificate any such changes shall be detailed and notified to the Product Appraisal Manager for consideration and review of the Certificate including the product appraisal criteria underlying it and appropriate action. Appraisals and their recoendations will be the subject of continuous review dependent upon the satisfactory performance of products. WSAA reserves the right to undertake random audits of product manufacture and installation. Where products fail to maintain appraised performance requirements the appraisal and its recoendations may be modified and reissued. Certificates will be reviewed and reissued at regular intervals not exceeding five (5) years. WSAA reserves the right to withdraw this Certificate at any time in its sole and absolute discretion for any reason. The following information explains a number of very important limits on your ability to rely on the information in this Certificate. Please read it carefully and take it into account when considering the contents of this Certificate. Any enquiries regarding this Certificate should be directed to the Product Appraisal Manager Phone: carl.radford@wsaa.asn.au Issue of Certificate This Certificate has been published and/or prepared by WSAA and nominated Project Manager and peer group of technical specialists (the Publishers). The Certificate and the underlying product appraisal criteria have been prepared for use within Australia only by technical specialists that have expertise in the function of products such as those appraised in the Certificate (the Recipients). By accepting this Certificate, the Recipient acknowledges and represents to the Publisher(s) and each person involved in the preparation of the Certificate and product appraisal criteria underlying it that the Recipient has understood and accepted the terms of this Disclaimer Limits on Reliance on Information and Recoendations Disclaimer of liability Neither the Publisher(s) nor any person involved in the preparation of the Certificate and product appraisal criteria underlying it accept(s) any liability for any loss or damage suffered by any person however caused (including negligence or the omission by any person to do anything) relating in any way to the Certificate or the product appraisal criteria underlying it. This includes (without limitation) any liability for any recoendation or information in the Certificate or any errors or omissions Intellectual Property and other rights WSAA does not undertake any assessment of whether the importation, manufacture, sale or use of the Product the subject of this Certificate infringes the intellectual property rights or proprietary rights of any person. Recipients of the Certificate should undertake their own assessment of whether (as relevant) the importation, manufacture, sale or use of the relevant Products infringe the intellectual property rights or other proprietary rights of any person. If the Product infringes intellectual property rights or other proprietary rights there is potential for the supply of the Products to be interrupted. From time to time WSAA and the other Publishers may receive notice of allegations that the importation, manufacture, sale or use of the Product infringes intellectual property rights or other proprietary rights. WSAA's policy is to not refer to such allegations in its Certificate or take any other steps to put Recipients on notice of such allegations. If, however, WSAA becomes aware that the allegations have been admitted or proved in Court, then WSAA may, at its discretion, take such steps as it considers appropriate. As such, Recipients acknowledge, agree and accept that WSAA may have information in its possession about intellectual property rights infringement allegations or other infringement allegations in relation to the Product which are not referred to or disclosed in this Certificate and which are not otherwise counicated to Recipients Need for independent assessment The information and any recoendation contained (expressly or by implication) in this Certificate are provided in good faith (and subject to the limitations noted in this Certificate). However, you should treat the information as indicative only. You should not rely on that information or any such recoendation except to the extent that you reach an agreement to the contrary with the Publisher(s). This Certificate does not contain all information that a person might require for the purposes of assessing any product discussed or appraised within it. The product appraisal criteria used in preparing this Certificate may not address all relevant aspects of the Product. Recipients should seek independent evidence of any matter which is material to their decisions in connection with an assessment of the Product and consult their own advisers for any technical information required. Any decision to use the Product should take into account the reliability of that independent evidence obtained by the Recipient regarding the Product. Recipients should also independently verify and assess the appropriateness of any recoendation in the Certificate, especially given that any recoendation will not take into account a Recipient s particular needs or circumstances. WSAA has not evaluated the extent of the product liability and professional indemnify insurance that the provider of the product maintains. Recipients should ensure that they evaluate the allocation of liability for product defects and any professional advice obtained in relation to the product or its specification including the requirements for product liability and professional indemnity insurance No Updating Neither the Publisher(s) nor any person involved in the preparation of this Certificate or the product appraisal criteria underlying it [has] [have] any obligation to notify you of any change in the information contained in this Certificate or of any new information concerning the Publisher(s) or the Product or any other matter No Warranty The Publisher(s) do[es] not, in any way, warrant that steps have been taken to verify or audit the accuracy or completeness of the information in this Certificate, or the accuracy, completeness or reasonableness of any recoendation in this Certificate. PA 1508 Issue 1 Rev 0 Page 2 of 17
3 SCHEDULE A APPENDIX A - PRODUCT CERTIFICATIONS Copies of the following Quality and Product Certification Certificates are available for downloading from the WSAA Members Only project portal website. SCHEDULE A1 - QUALITY MANAGEMENT SYSTEMS Business Location: AG + Co, Rheniumhaus Otto-Hahn-Str. 2, D Rehau, GERMANY There are 30 more locations of administration offices and plants included in this certification as detailed in the attachment. Quality Systems Standard ISO 9001:2008 Certificate Registration no Certifying agency First date of certification TÜV Rheinland Cert GmbH NA Current date of certification 29 June 2015 Expiry date of certification 28 June 2018 SCHEDULE A2 - QUALITY MANAGEMENT SYSTEMS Business Location: Pty Ltd PTY LTD, Suite 1.02, Level 1, Quad 1, 8 Parkview Drive, Sydney Olympic Park NSW 2127 Water Industry Standard WSA 137:2013 Certificate Registration no. AMI Certifying agency ApprovalMark First date of certification 30/11/2017 Original Certified 30/11/2017 Expiry date of certification 30/11/2022 Current Certification 30/11/2017 PA 1508 Issue 1 Rev 0 Page 3 of 17
4 SCHEDULE A SCHEDULE A3 MFPA WEIMAR GERMANY INSPECTION AND CERTIFICATION BODIES Testing facility: MFPA Official Testing Centre located in Weimar, Germany Certification Standard Certificate Registration No. Certifying agency First date of certification Current date of certification Expiry date of certification a) Inspection body - Type A to DIN EN ISO/IEC 17020:2012 b) Laboratory Accreditation DIN EN ISO/IEC 17025:2005 c) Certification Body - DIN EN ISO/IEC 17065:2005 a) D-IS b) D-PL c) D-ZE DakkS (Deutsche Akkreditierungsstelle GmbH) a) 8 May 2012 b) NA c) 7 November 2014 a) 19 December 2016 b) 19 December 2016 c) 7 November 2014 a) 18 December 2021 b) 18 December 2021 c) 5 November 2019 PA 1508 Issue 1 Rev 0 Page 4 of 17
5 TABLE B1 AWASHAFT DN 400 PP MS PRODUCT SCHEDULE Product Supplier Picture AWASHAFT DN 400/315 PP Chamber Base GD AWASHAFT DN 400/315 PP Chamber Base RML s AWADUCT DN 400/315 or DN 315/250 Offset Reducer with lip sealing ring; Material RAU-PVC 1100, Colour RAL 8023 red brown (optional item, not included in this appraisal, but included in PA 1508 Part 2) s AWADUCT KGB PVC- U Bend SN8 with lip sealing rings from 15 to 87 ; Material RAU- PVC 1100, Colour RAL 8023 red brown (AWADUCT PVC SN8 Classic Range to EN 1401 (equivalent to AS/NZS 1260) AWADUCT PP Ball joint continuously adjustable up to +/- 7.5 o horizontally or vertically with EPDM sealing rings (Safety- Lock) (optional item, not included in this appraisal; alternative PVC-U bends locally available to AS/NZS 1260) (optional item, not included in this appraisal, but included in PA 1508 Part 2) Extension pipe or riser DN 300 or DN 225 PVC-U DWV SN8 to AS/NZS 1260 Installer PA 1508 Issue 1 Rev 0 Page 5 of 17
6 Product Supplier Picture DN 150 PVC-U push-in socket plugs to AS/NZS 1260 for unused branch of triple inlet RML base unit Injection moulded DN 300 or DN 225 PVC-U SWJ push on cap to AS/NZS 1260 Injection moulded DN 300 or DN 225 PVC-U solvent weld on cap with screw lid and RR seal to AS/NZS 1260 PE Shroud Pipe (450 dia minimum) to AS/NZS 4130, Concrete Surround and Surface Fittings (DI access cover to AS 3996 Class B or D) Installer Installer Installer Installer The DN 400 GD chamber base measures 530 in length and 360 in height (reducer not included in this appraisal, but in PA 1508 Part 2) and the DN 400 RML measures 480 in length and 360 in height (reducer not included in this appraisal, but in PA 1508 Part 2.). FIGURE B1 AWASHAFT DN 400 PP MS BASE UNIT TABLE B2 AWASHAFT DN 400 PP MS BASE Chamber base unit DN Inlet / outlet DN/OD M () Z () N () Length () 2 () AWASHAFT DN/OD 400 GD chamber base (straight connecting passage) AWASHAFT DN/OD 400 RML (3 inlets, 1 outlet) PA 1508 Issue 1 Rev 0 Page 6 of 17
7 TABLE B3: AWASHAFT DN 600 PP MC PRODUCT SCHEDULE Product Supplier Picture AWASHAFT DN 600 PP Chamber Base as per the manufacturer schedule (refer to following pages) AWASHAFT DN 600 PP riser AWADUCT PP Pipes and Fittings (optional item, not included in this appraisal, but in PA 1508 Part 2) AWADUCT PP Pipes and Fittings (optional item, not included in this appraisal, but in PA 1508 Part 2) AWADOCK PP Fittings (optional item, not included in this appraisal, but in PA 1508 Part 2) Push on caps according to water agency requirements PE Shroud Pipe (800 dia minimum) to AS/NZS 4130, Concrete Surround and Surface Fittings (DI access cover to AS 3996 Class B or D) Installer Not included in this appraisal Installer not included in this appraisal PA 1508 Issue 1 Rev 0 Page 7 of 17
8 FIGURE B2 AWASHAFT DN 600 PP MC BASE UNIT TABLE B4 AWASHAFT DN 600 PP MC BASE Chamber base unit Bend DN/OD Inlet / outlet Effective height N h ¹ h 2 AWASHAFT PP DN/OD 600 chamber bases, straight ( Refer to Figure B2) straight FIGURE B3 AWASHAFT PP DN 600 PP MC BASE - RML90º, T-PIECE 90º,AG90º PA 1508 Issue 1 Rev 0 Page 8 of 17
9 TABLE B5 AWASHAFT PP DN 600 PP MC BASE - RML90º,T-Piece 90º,AG90º Chamber base unit Bend DN/OD Inlet / outlet Effective height N h ¹ h RML90º RM 270º ML90º RML90º/270º AG90º AG270º PA 1508 Issue 1 Rev 0 Page 9 of 17
10 FIGURE B4 AWASHAFT PP DN 600 PP MC BASE -30º,60º 90º Deflection TABLE B6 AWASHAFT PP DN 600 PP MC BASE 30º,60º 90º deflection Chamber base unit Angle deflection DN/OD Inlet / outlet Effective height N h ¹ h 2 30º Standard 60º º FIGURE B5 AWASHAFT PP DN 600 PP RISER PIPE TABLE B7 AWASHAFT PP DN 600 PP RISER PIPE Riser Pipe Installation D a D i Without Inliner PA 1508 Issue 1 Rev 0 Page 10 of 17
11 Riser Pipe Installation D a D i TABLE B8: AWASHAFT DN 800 PP MC PRODUCT SCHEDULE Product Picture Supplier AWASHAFT DN 800 PP Chamber Base as per the manufacturer schedule (refer to following pages) AWASHAFT DN 800 PP riser (with and without ladder) DN 800/625 PP cone Elastomeric seals for components a) DN800 lip sealing for top of the base unit b) DN160, 200, 250, 315 and 400 lip sealing ring for inlet/outlet c) DN800 lip sealing ring MOL PA 1508 Issue 1 Rev 0 Page 11 of 17
12 Product Picture Supplier for riser rings d) DN625 lip sealing ring for top of the cone AWADUCT PP Fittings (optional item, not included in this appraisal, but in PA 1508 Part 2) AWADUCT PP Fittings (optional item, not included in this appraisal, but in PA 1508 Part 2) AWADOCK PP Fittings (optional item, not included in this appraisal, but in PA 1508 Part 2) Push on caps according to water agency requirements Ladder This item is not included in the appraisal as DN800 is being assessed as MC and there is no man entry. Installer (not included in this appraisal) (not included in this appraisal) Rehau supplies the ladders. The supports of Ladders are injection moulded into the risers. The steps are assembled PA 1508 Issue 1 Rev 0 Page 12 of 17
13 Product Picture Supplier 1000/800 polymer bearing ring DN625 to EN Material Polymer, Grey colour FIGURE B6 AWASHAFT PP DN 800 MC STANDARD BASES TABLE B9 AWASHAFT PP DN 800 MC STANDARD BASES Chamber base unit Bend DN/OD Inlet / outlet Effective height N Weight kg ºGD PA 1508 Issue 1 Rev 0 Page 13 of 17
14 Chamber base unit Bend DN/OD Inlet / outlet Effective height N Weight kg RML90º RM 270º ML90º RML90º/270º AG90º AG270º PA 1508 Issue 1 Rev 0 Page 14 of 17
15 FIGURE B7 AWASHAFT PP DN 800 PROJECT SPECIFIC BASES - STRAIGHT TABLE B10 AWASHAFT PP DN 800 PROJECT SPECIFIC BASES - STRAIGHT Chamber base unit DN/OD Inlet / outlet Effective height N weight STRAIGHT FIGURE B8 AWASHAFT PP DN 800 PROJECT SPECIFIC BASES - ANGLED PA 1508 Issue 1 Rev 0 Page 15 of 17
16 TABLE B11 AWASHAFT PP DN 800 PROJECT SPECIFIC BASES - ANGLED Chamber base unit DN/OD Inlet / outlet Effective height N weight ANGLED (Max 45º) (Max 30º) FIGURE B9 AWASHAFT PP DN 800 CONE TABLE B12 AWASHAFT PP DN 800 CONE CONE Version N max H Min weight DN800 Without ladder PA 1508 Issue 1 Rev 0 Page 16 of 17
17 FIGURE B10 AWASHAFT PP DN 800 RINGS TABLE B13 AWASHAFT PP DN 800 RINGS RINGS Version Effective Length N weight Inc Vertical latter Inc Vertical latter Inc Vertical latter DN800 Inc Vertical latter Inc Vertical latter Inc Vertical latter Inc Vertical latter PA 1508 Issue 1 Rev 0 Page 17 of 17
Tucks Industrial Packings & Seals Pty Ltd PRODUCT APPRAISAL REPORT 1425 Issue 2
WSAA Product Appraisal 1425 Issue 2 1 Tucks Industrial Packings & Seals Pty Ltd PRODUCT APPRAISAL REPORT 1425 Issue 2 Flange Gaskets WSA 109-2011 Industry Standard for Flange Gaskets and O-rings Publication
More informationGeorg Fischer Waga NV PRODUCT APPRAISAL REPORT 1428 Issue 2
WSAA Product Appraisal 1428 1 Georg Fischer Waga NV PRODUCT APPRAISAL REPORT 1428 Issue 2 Georg Fischer Waga Multi/Joint 3000 Plus Restrained Joint Couplings, End Caps, Bends and PE Adaptors EN 14525:2004
More informationClearmake Pty Ld. Product Appraisal Report TWA 0803
Clearmake Pty Ld Product Appraisal Report TWA 0803 Separator Systems for Light Liquids CB1.0 SS 720L/hr CL1.5 SS 720L/hr CL1.5 SSD 1440L/hr CL3.0 SS 1600L/hr CL3.0 SSD 1140L/hr Published - February 10
More informationNEW: RAUFILAM -E COLOUR ALWAYS THE RIGHT CHOICE. Industrial hoses, with and without fabric lining
NEW: RAUFILAM -E COLOUR ALWAYS THE RIGHT CHOICE Industrial hoses, with and without fabric lining PRESSURE-RESISTANT HOSES IN FOOD-GRADE QUALITY RAUFILAM -E fibre reinforced, design and KTW approved Proven
More informationPRE-RELEASE VERSION (FDIS)
IEC 61238-1-1 Edition 1.0 2018-02 PRE-RELEASE VERSION (FDIS) Compression and mechanical connectors for power cables Part 1-1: Test methods and requirements for compression and mechanical connectors for
More informationWELLINGTON, NEW ZEALAND. PURSUANT to section 152 of the Land Transport Act Land Transport Rule: Vehicle Standards Compliance 2002
WELLINGTON, NEW ZEALAND PURSUANT to section 152 of the Land Transport Act 1998 I, Mark Gosche, Minister of Transport, HEREBY make the following ordinary Rule: Land Transport Rule: Vehicle Standards Compliance
More informationHydroflow Distributors (AUS) Pty Ltd PRODUCT APPRAISAL REPORT PA1710
WSAA Product Appraisal 1710 1 Hydroflow Distributors (AUS) Pty Ltd PRODUCT APPRAISAL REPORT PA1710 PE100 Electrofusion and Spigot Fittings AS/NZS 4129:2008 Fittings for polyethylene (PE) pipes for pressure
More informationDublin Airport Chauffeur Code of Conduct Dublin Airport Chauffeurs Code of Conduct. Dublin Airport Parking
We Dublin Airport Chauffeurs Code of Conduct Effective 1 st June 2017 1 1 Introduction Chauffeur Permits The purpose of the chauffeur operation at Dublin Airport is to provide chauffeur services for customers
More informationPOWER SYSTEM INCIDENT REPORT NORTHERN POWER STATION STABILISER OUTAGE APRIL AND MAY 2010
POWER SYSTEM INCIDENT REPORT NORTHERN POWER STATION STABILISER OUTAGE APRIL AND MAY PREPARED BY: ESOPP VERSION:. DATE: November FINAL OUTAGE APRIL AND MAY Disclaimer (a) Purpose - This report has been
More informationHDPE PIPE SYSTEMS PRODUCT CATALOGUE.
HDPE PIPE SYSTEMS PRODUCT CATALOGUE www.acu-tech.com.au This is to certify that: The Trustee for The Morren Family Trust ABN 52 394 633 042 Trading As Acu-Tech Piping Systems 119 Kelvin Road Maddington
More informationVehicle Importer Terms and Agreement Form
Vehicle Importer Terms and Agreement Form This document outlines the Terms applicable to an Electric Vehicle Importer (the Importer ) wishing to participate in SEAI s Electric Vehicle Grant Scheme (the
More informationPressure/ Water Polyethylene (PE) Pipes - Series 1 to AS/ NZS 4130:2009 millimetres SDR 41
Pressure/ Water Polyethylene (PE) Pipes - Series 1 to AS/ NZS 4130:2009 SDR 41 SDR 33 SDR 26 Mean Maximum PN4 PE100 / PN3.2 PE80 PN4 PE80 PN6.3 PE100 out-of- Wall Mean inside Wall Mean inside Wall Mean
More informationChanging your vehicle
Information Guide G6 This Information Guide deals with the regulations and procedures involved in changing the vehicle associated with an SPSV licence. Changes of vehicle are permitted, provided the replacement
More informationPOWER SYSTEM OPERATING INCIDENT REPORT TRIPS OF YALLOURN W POWER STATION UNITS W1 AND W3 ON 14 NOVEMBER 2012
POWER SYSTEM OPERATING INCIDENT REPORT TRIPS OF YALLOURN W POWER STATION UNITS W1 AND W3 ON 14 NOVEMBER 2012 PREPARED BY: System Performance and Commercial DATE: 7 March 2013 FINAL Disclaimer Purpose This
More informationPMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks
- 1 - PMD DRIVER RELOCATION KIT For 1994-1999 Chevy 6.5L Diesel Trucks Part# 1036520 -- Installation Instructions -- PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION. - 2 - Kit Contents BD P/N#
More informationPOWER SYSTEM OPERATING INCIDENT REPORT TRIP OF 220 KV C BUSBAR AT GORDON POWER STATION ON 26 NOVEMBER 2011
POWER SYSTEM OPERATING INCIDENT REPORT TRIP OF 220 KV C BUSBAR AT GORDON POWER STATION ON 26 NOVEMBER 2011 PREPARED BY: Electricity System Operations Planning and Performance DATE: 22 March 2012 FINAL
More informationManaging Electrical Safety on Boats
Managing Electrical Safety on Boats Note Throughout this document there are several specific terms with which you should be familiar, and they are defined in the dictionary below. These terms are identified
More informationLand Transport Rule: Vehicle Standards Compliance 2002 Rule 35001/1 Rule requirements...2
Part 1 Land Transport Rule: Vehicle Standards Compliance 2002 Rule 35001/1 Rule requirements...2 Section 1 Application...2 1.1 Title...2 1.2 Scope of the rule...2 1.3 Date when rule comes into force...3
More informationPOWER SYSTEM OPERATING INCIDENT REPORT: TRIP OF 837 TARONG MT. ENGLAND 275 KV LINE AND MT. ENGLAND NO KV BUSBAR ON 30 OCTOBER 2011
POWER SYSTEM OPERATING INCIDENT REPORT: TRIP OF 837 TARONG MT. ENGLAND 275 KV LINE AND MT. ENGLAND NO.1 275 KV BUSBAR ON 30 OCTOBER 2011 PREPARED BY: Electricity System Operations Planning and Performance
More informationInstallation Guide. Installation Requirements for Rainwater Tanks
Installation Requirements for Rainwater Tanks Immediate Securing of Tank: It is the purchaser s responsibility to ensure that the tank is secured immediately following delivery, either by tying down with
More informationPOWER SYSTEM OPERATING INCIDENT REPORT SIMULTANEOUS TRIP OF 5A6 MT PIPER BANNABY 500 KV LINE AND MT PIPER NO. 2 UNIT ON 9 FEBRUARY 2012
POWER SYSTEM OPERATING INCIDENT REPORT SIMULTANEOUS TRIP OF 5A6 MT PIPER BANNABY 500 KV LINE AND MT PIPER NO. 2 PREPARED BY: Electricity System Operations Planning and Performance DATE: 5 June 2012 FINAL
More informationPolymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened
Roofing Product Data Sheet Edition 06.2013 Version no. 01 Sikaplan -20 G Polymeric membrane for roof waterproofing Product Description Sikaplan -20 G (thickness 2.0(- 5 % / + 10 %)mm) is a polyester reinforced
More informationCONTENTS. Introduction. Thank you for purchasing the AlcoSense Precision+ breathalyser.
User Manual Introduction CONTENTS Thank you for purchasing the AlcoSense Precision+ breathalyser. The AlcoSense Precision+ is certified to Australian Standard AS3547 Type 2 Quantitative Device and is one
More informationHATCHGRIP Installation Instructions/Operation and Maintenance Manual
HATCHGRIP Installation Instructions/Operation and Maintenance Manual Models: HTG-PCG Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Operation... 3 Installation
More informationCERTIFICATE. Siemens AG Siemens Certification Authority. has implemented the specification listed below for the following certification services.
CERTIFICATE This is to certify that Werner-von-Siemens-Straße 1 80333 München has implemented the specification listed below for the following certification services. Scope: / Trust Service Provider (TSP)
More informationOFFICIAL IPCO Policy Document
Policy Name: IPCO consultation process Version: 1.0 Date: August 2018 1. Context i. IPCO will always seek to engage with stakeholders where such engagement is consistent with our statutory obligations
More informationHOW TO INSTALL YOUR BOV
Product Name: Product Description: Product Number: Subaru Dual port Fits WRX 01 07, WRX STI 01 08, Forester XT 06 TS-0205-1015/TS-0205-1016 ------------------------------------------------------------------------------------------------------------------------
More informationDrain Waste & Vent (DWV) Systems SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS
Drain Waste & Vent (DWV) Systems SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS contents Drain Waste & Vent (DWV) Systems SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS product
More informationHawle Haku PE Pipe Saddle
Hawle Haku PE Pipe Saddle Scan for more information Technical Guide W9.1 Specifically designed as a PE mechanical connection solution. Suitable for PE pipes of all pressure ratings up to PN 16. DN40-360.
More informationARAI/TA(4G_RV)/HORIBA/MEXA 584L/ Dated 25 Mar 2014
CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES M/s Horiba India Pvt. Ltd. Room 1521, 15 th Floor, Eros Corporate Tower, Nehru Place New Delhi 110 019 Cert Annex Drg Total 1 7 0 8 pgs Exhaust
More informationREQUEST FOR PROPOSAL
Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF PIPES, FITTINGS AND FLANGES TO PALABORA COPPER TENDER NUMBER: RFP.PC.2015/144 PART 1 PROPOSAL INFORMATION AND CONDITIONS Page 1 Supply and Delivery
More informationTIDALFLUX 2300 F Quick Start
Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS
More informationPower System Operating Incident Report Trip of Murray Lower Tumut No kv Transmission Line at Murray End Only on 18 November 2013
Power System Operating Incident Report Trip of Murray Lower Tumut No.66 0 kv Transmission PREPARED BY: AEMO Systems Capability DATE: 1 December 201 FINAL Version Release History VERSION DATE BY CHANGES
More informationPalabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS
Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS THIS CONTRACTS IS FOR BIDDERS THAT ARE MORE THAN 26% BLACK
More informationRMS CONDITIONAL REGISTRATION SCHEME HISTORIC (CRS-H) RULES FOR MEMBERS. Mustang Owners Club Australia (N S W) Inc.
Mustang Owners Club Australia (N S W) Inc. Email: cpregistrar@nsw.mustang.org.au 1-12-16 INTRODUCTION 1. The Mustang Owners Club of Australia (NSW) Inc. (herein known as the Club ) is approved by the Roads
More informationSUPRA JZA80 TWIN TURBO BLOW-OFF VALVE ADAPTOR INSTRUCTIONS
IMPORTANT NOTES ON FITTING YOUR SUPRA TWIN TURBO ADAPTOR Turbosmart recommends that your Blow Off Valve (BOV) and Adaptor kit is fitted by an appropriately qualified technician. ADAPTOR KIT CONTENTS Please
More informationBACS APPROVED BUREAU SCHEME SUPPORT GUIDELINES
BACS APPROVED BUREAU SCHEME SUPPORT GUIDELINES VERSION 8.2 May 2017 CONTENTS 1 DOCUMENT INFORMATION 4 1.1 VERSION HISTORY 4 1.2 DOCUMENT REVIEWERS 4 1.3 COPYRIGHT STATEMENT 4 2 CONFIDENTIALITY 4 3 INTRODUCTION
More informationDEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016
Trade and Industry, Department of/ Handel en Nywerheid, Departement van 438 National Regulator for Compulsory Specifications Act (5/2008): Amendments to the Compulsory Specification for Earth Leakage Protection
More informationHyLAW. HyDrail Rail Applications Assessment. Main Author(s): [Dainis Bošs, Latvian Hydrogen association] Contributor(s):
HyLAW HyDrail Rail Applications Assessment Main Author(s): [Dainis Bošs, Latvian Hydrogen association] Contributor(s): Status: [V1] Dissemination level: [public] 1 Acknowledgments: The HyLAW project has
More informationNCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles
The UK trade body for the caravan, motorhome, caravan holiday and park home industry. NCC Leisure Battery Verification Scheme Leisure Accommodation Vehicles Page 1 of 11 1 Scope The NCC Battery Verification
More informationInformation for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN
Information for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN 15085-2 Certificate According DIN EN 15085-2 Railway applications - Welding of railway vehicles and components
More informationAmerican National Standard for Lighting Equipment Voltage Surge Requirements
American National Standard for Lighting Equipment Voltage Surge Requirements Secretariat: National Electrical Manufacturers Association Approved: December 21, 2017 American National Standards Institute,
More informationWARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN
WARRANTY POLICY Revision D 2014, Solectria Renewables, LLC DOCIN-070360 1 Product Warranty & RMA Policy 1. Warranty Policy Warranty Registration: It is important to have updated information about the inverter
More informationTOOLS REQUIRED General mechanic tools
Product Name: Product Description: Product Number: BOOST TEE Manual Boost Controller TS-0101-1001 ------------------------------------------------------------------------------------------------------------------------
More informationARAI/TA (4G)/AIRVISOR/AVG500/ Dated 17 th Apr 2017
Airvisor Technologies Pvt. Ltd. H-155, Adhyapak Nagar, Nangloi, New Delhi 110041. CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES Cert Annex Drg Total 1 7 0 8 pgs Exhaust Gas Analyzer Model
More informationARAI/TA(4G_RV)/SMS/D680/ Dated 21 st Mar 2015 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES
CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES M/s SMS Autoline Equipments Pvt. Ltd. Plot No.AP215, 6 th Street, I Block, Vallalar Colony, Anna Nagar (West) Chennai 600 040 Cert Annex Drg
More informationPrüffeld der Schaltwerke
Report No.: 16-043-MS Sheet: 2 Notes 1. The testing station of the Siemens switchgear factory (Prüffeld der Schaltwerke),, Berlin, has been approved by the DAkkS (German accreditation body) for rendering
More informationWP2 - CFD Private Network Meter Commissioning, Proving and Calibration Tests
WP2 - CFD Private Network Meter Commissioning, Proving and Calibration Tests EMRS Working Practice Public Version: 2.0 Date: 13 October 2017 Table of Contents Change Amendment Record 3 1. Introduction
More informationConstruction and Connection of Street Light Assets
Construction and Connection of Street Light Assets 1. INTRODUCTION... 2 2. FURTHER INFORMATION... 3 3. DEFINITIONS... 3 3.1 Designer... 3 3.2 Street Light Asset Owner... 3 3.3 Road Owner... 4 3.4 Developer...
More informationRig Master Power by Mobile Thermo Systems Inc.
RigMaster Power Dealer Warranty Policy The Limited Warranty This limited warranty applies to the RigMaster Auxiliary Power Unit (RigMaster APU) which consists of the following components: 1. The generator
More informationToro Sprayer Calibration Tool
Commercial Products Toro Sprayer Calibration Tool User Guide & Installation Instructions Toro Sprayer Calibration Tool 1 Table of Contents Introduction... 2 Program Instructions... 4 Toro Software End
More informationREAL WORLD DRIVING. Fuel Efficiency & Emissions Testing. Prepared for the Australian Automobile Association
REAL WORLD DRIVING Fuel Efficiency & Emissions Testing Prepared for the Australian Automobile Association - 2016 2016 ABMARC Disclaimer By accepting this report from ABMARC you acknowledge and agree to
More informationTERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT
TERMS AND CONDITIONS OF PARKING AT PALMERSTON NORTH AIRPORT 14 December 2017 Palmerston North Airport Limited ( PNAL ) provides travellers and other members of the public with multiple car parking options
More informationTank Installation Instructions
July 2018 RX PLASTICS 10,000-30,000 Litre Plastic MAX Water Tanks Tank Installation Instructions Warranty Terms and Conditions Tank Lifting Instructions RX PLASTICS LTD PO Box 360 Ashburton Phone +64 3
More informationINCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL
INCOMING INSPECTION DELEGATION GUIDELINES FOR ALENIA SUPPLIERS PROGRAM: ALL THE CONTENT OF THIS DOCUMENT IS THE PROPERTY OF ALENIA AERONAUTICA S.p.A. THIS DOCUMENT IS SUPPLIED IN CONFIDENCE AND COMMERCIAL
More information1000mA - 650mA Phase Dimmable LED Driver
Installation Guide DGLC1000C25PD 1000mA - 650mA Phase Dimmable LED Driver PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU
More informationPOWER SYSTEM OPERATING INCIDENT REPORT LIGHTNING STRIKES IN TASMANIA AND PACIFIC ALUMINIUM POTLINE LOAD REDUCTIONS 21 MARCH 2013
POWER SYSTEM OPERATING INCIDENT REPORT LIGHTNING STRIKES IN TASMANIA AND PACIFIC ALUMINIUM POTLINE LOAD REDUCTIONS MARCH 03 PREPARED Y: Systems Capability DATE: 7 June 03 FINAL Disclaimer Purpose This
More informationAS/NZS 3112:2004 AS/NZS
AS/NZS 3112:2011 Incorporating Amendment No. 1, 2, and 3 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets Superseding AS/NZS 3112:2004 AS/NZS 3112:2011 AS/NZS 3112:2011
More informationd. Note: LPG conversions are acceptable providing the relevant Vehicle Declaration is completed by the HSVOC Registrar.
Title: Historic & Classic Vehicles Registration Rules Number of Pages: 5 Reviewed By: Michael Benton Issue Date: 9 th November 2018 UNCONTROLLED IF PRINTED Replaces Issue: 12th February 2017 1. BACKGROUND
More informationK1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1
Fitting Instructions for Basic Carrier x 4 x 4 x 1 x 8 x 4 x 1 x 4 x 1 x 4 x 1 x 1 x 2 Revision No: 1A 1 MAX kgs (lbs) W/P WHD Holden Spark, 5dr Hatch 16-+ AU 50 kgs (110 lbs) 50 kgs (110 lbs) Spark, 5dr
More informationVertabelo Academy. Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms
Vertabelo Academy Terms of Service PLEASE READ ALL OF THE FOLLOWING TERMS OF SERVICE BEFORE USING THIS WEBSITE A. General Terms 1. These Terms of Service ("ToS") govern users access to and use of the Vertabelo
More informationUnderstanding BS 1363 Amendment No.4
Intertek Hilton House, Corporation Street, Rugby, Warwickshire, CV21 2DN UK info.uk@intertek.com 01788 578435 www.intertek.com Introduction A new Amendment applying to several parts of the BS 1363 standard
More informationProcess Inline Filter Protective filter PLF2-9HF
Process Inline Filter Protective filter PLF2-9HF Specifications Nominal size: DN 300 - DN 600 Q s max: 3000 m 3 /h p s max: 16 bar Filtration ratings: 1-90 µm 1. GENERAL Product description Protective
More informationDIVISION 311 MISCELLANEOUS ELECTRICAL RULES
DIVISION 311 MISCELLANEOUS ELECTRICAL RULES 918-311-0000 Design, Planning and Lay Out of Electrical Installations by Supervising Electricians A licensed supervising electrician may design, plan and lay
More informationSTC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way
STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way Ordering Part No. = (e.g., E 1/2-3-S) Indicator / Control E 1/2 - - - 3-S Model Name Electric Actuated Valves E Port Size
More informationThe breath sample was not strong enough to detect a reading. After warm up, please blow strong and steadily into the mouthpiece.
Personal mouthpiece The Zenith+ features a built-in permanent mouthpiece for personal use. Push the hook to the side to extend the mouthpiece for personal testing. To use a separate mouthpiece with the
More informationThe Road to Safety and Compliance Starts with You! ISRI DOT Self-Audit Checklist
The Road to Safety and Compliance Starts with You! ISRI DOT Self-Audit Checklist ISRI DOT Self-Audit Checklist Disclaimer: The material herein is for informational purposes on and is provided on an as-is
More informationCertification Scheme
Certification Scheme Water-based surface-embedded heating and cooling systems in accordance with DIN EN 1264 (Version: November 2009) DIN CERTCO Alboinstraße 56 12103 Berlin Tel: +49 30 7562-1131 Fax:
More informationPVI 60KW, PVI 82KW, PVI 95KW
PVI 60KW PVI 82KW PVI 95KW WARRANTY MANUAL Commercial, Grid-Tied Photovoltaic Inverters 2008, Solectria Renewables LLC Subject to Change DOC-020099 rev 024 1 1 Product Warranty & RMA Policy Warranty Policy
More informationSound-absorbing spacer Sorp10
Sponsor: Reference number: 7.3 / 27080 This document is only a translated version; not legally attested Max Frank GmbH & Co. KG Mitterweg 1 94339 Leiblfing Federal Institute for Materials Research and
More informationTERMS AND CONDITION OF USE FOR THE AUTHORISED VEHICLE AREA
TERMS AND CONDITION OF USE FOR THE AUTHORISED VEHICLE AREA INTRODUCTION These Terms and Conditions of Use apply to the Authorised Vehicle Area which is owned and operated by or on behalf of Heathrow Airport
More informationP1A Pressure Sensor. Description. Features. Applications MAIN FEATURES
P1A Pressure Sensor Description P1A family features a highly modular compact geometry. This modularity and extensive range of options offered by the P1A family make the advantages of Ceramic Capacitive
More informationNational Board Update
National Board Update Presentation to the Valve Repair Council June 2, 2016 Prepared by: Joseph F. Ball, P.E. National Board Update National Board activities Who we are and what we do National Board Inspection
More informationPS 127 Abnormal / Indivisible Loads Policy
PS 127 Abnormal / Indivisible Loads Policy June 2017 Version 1.5 Statement of legislative compliance This document has been drafted to comply with the general and specific duties in the Equality Act 2010;
More informationGemeinschaft Thermisches Spritzen
Gemeinschaft Thermisches Spritzen Quality Management for Thermal Spraying GTSPA002 GTS Certificate Guideline May 2012 Gemeinschaft Thermisches Spritzen e. V. Association of Thermal Sprayers GTSPA002 Status:
More informationA Member of the. Integrated Metering Technologies
I n s t a l l a t i o n M a n u a l A Member of the Integrated Metering Technologies 1.0 General and Safety Do not install, operate or maintain this flow meter without reading, understanding and followingthe
More informationRIA - VAC SYSTEM PROAGRIA Landbrug A/S Aggershusvej 7 Tlf: DK-5450 Otterup Fax:
RIA - VAC SYSTEM RIA - VAC ASSEMBLY-DIRECTIONS FOR DN 200-250-300 mm RIA VAC LIQUID MANURE DISCHARGE SYSTEM PLAN LONGITUDINAL SECTION (Pipeline with closure cover) PLAN LONGITUDINAL SECTION (Pipeline with
More information08-Dec-10. VCA job number: CSL Date: 08 December Dear Sirs,
VCA job number: CSL225489 Date: 08 December 2010 Dear Sirs, 1. The vehicle type / component described on the attached approval(s) has been tested and meets the requirements of the ECE Regulation / EEC
More informationHOW TO INSTALL YOUR BOV
Product Name: Product Description: Product Number: BMW Kompact BOV Kit Model specific BOV Kit TS-0203-1050/TS-0203-1250 ------------------------------------------------------------------------------------------------------------------------
More informationPOWER SYSTEM OPERATING INCIDENT REPORT TRIP OF B 220 KV BUSBAR AT GEORGE TOWN ON 27 NOVEMBER 2012.
POWER SYSTEM OPERATING INCIDENT REPORT TRIP OF B 220 KV BUSBAR AT PREPARED BY: System Performance & Commercial DATE: 1 March 2013 FINAL Disclaimer Purpose This report has been prepared by the Australian
More informationCOMPONENT HOMOLOGATION POLICY AND PROCEDURE
COMPONENT HOMOLOGATION POLICY AND PROCEDURE Policy number THS001 Version V2 Approved by Board 2 December 2014 Responsible person Status CEO Public Fees reviewed Scheduled review date 8 November 2016 31
More informationPrinciple Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK
-GB-2017-01: Defining the requirements for a GS mark approval Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act about
More informationPOWER SYSTEM INCIDENT REPORT: TRIP OF NO 1 AND 2 NEW OSBORNE 66 KV BUSBARS ON 26 SEPTEMBER 2010
POWER SYSTEM INCIDENT REPORT: TRIP OF NO 1 AND 2 NEW OSBORNE 66 KV BUSBARS ON 26 SEPTEMBER 2010 PREPARED BY: Electricity System Operations Planning and Performance FINAL Disclaimer (a) Purpose - This report
More information650mA Phase Dimmable LED Driver
Installation Guide DGLC650C18PD PATENT PENDING REGISTERED DESIGN Designed in Australia to meet Australian Standards and installation conditions DIGINET.NET.AU Diginet Control Systems Pty Ltd ABN 89 095
More informationAIRBUS EASA AD activities AD implementation
E. BLANCANEAUX A318/19/20/30 HO continued airworthiness A. PANNIER A330/A340 Cont airworthiness manager Presented by: AIRBUS EASA AD activities AD implementation 10 th EASA 3th workshop - Airbus Airbus-
More information"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.
1. Definitions "Australian Consumer Law" means the Australian Consumer Law set out in Schedule 2 to the Competition and Consumer Act 2010 (Cth) as given effect under Part XI of the Competition and Consumer
More informationInfrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)
Infrastructure & Power FP M c Cann Tel: +44(0)1455 290 780 Fax: +44(0)1455 292 189 Infrastructure & Power Infrastructure & Power Power Infrastructure Cable Trough Systems FP McCann offers a specialist
More informationPractice Note on the Sourcing of Threaded Rod Used for Foundation Bolts
MATERIALS Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts Authors: Kevin Cowie, Alistair Fussell Affiliation: Steel Construction New Zealand Inc. Date: 20 th February 2018 Ref.:
More informationSeries AA Roller Door
Series AA Roller Door Installation Instructions TAUREAN DOOR SYSTEMS Phone (03) 9721-8366 www.taureands.com.au Extreme safety warning. Safe practices must be observed when working at heights, lifting roller
More informationROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N
DESIGN GUIDE PURLINS AND GIRTS ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS S&T029N JUL 2015 CONTENTS INTRODUCTION 2 Acknowledgements 2 Disclaimer 2 Product Technical Statement 3 Producer Statement
More informationPOWER SYSTEM OPERATING INCIDENT REPORT MULTIPLE CONTINGENCY EVENT IN NORTH WEST TASMANIA ON 6 APRIL 2012
POWER SYSTEM OPERATING INCIDENT REPORT MULTIPLE CONTINGENCY EVENT IN NORT WEST TASMANIA ON 6 APRIL 2012 PREPARED BY: Systems Capability DATE: 28 September 2012 FINAL IN NORT WEST TASMANIA ON 6 APRIL 2012
More informationInstruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:
Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse
More informationCertificate of Acceptance
HILTI TE6, TE7 and TE30 36 volt hand drills Product Description Product Image TE6, TE7 and TE30 36 volt hand drills TE6 and TE7 are existing Hilti drilling units to be replaced, through continued renewals
More informationANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions
ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS Article 1 General Provisions 1. This Annex shall apply to motor vehicles in UNECE vehicle regulations' category M1 as well as parts and equipment regulated
More informationTBP SERIES PUMPS OPERATION & PARTS MANUAL
TBP SERIES PUMPS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements
More informationThis Distribution Charter explains how PLS distributes collective licensing
Distribution Charter 1 This Distribution Charter explains how PLS distributes collective licensing revenues. 1. Introduction 1.1 Collective licensing for published materials was introduced in the UK in
More informationProcedure PR D Electrical Permits. Engineering Procedure Electrical Distribution Unit. Version 1.0. Date in Force: 4 November 2015
Engineering Procedure Electrical Distribution Unit PR D 78500 Electrical s Version 1.0 Date in Force: 4 November 2015 Procedure UNCONTROLLED COPY WHEN PRINTED Approved by: Sean Budge Manager Electrical
More informationLP 087/ INTRODUCTION
1.0 INTRODUCTION 1.1 An amateur built VariEze aircraft, registration N914VE departed Lethbridge, Alberta on a VFR flight to Airdrie, Alberta. Just after take off, as the aircraft was departing the downwind
More informationMaintenance of Signal Sighting and Signals
Discipline: Engineering (Signalling) Category: Standard Maintenance of Signal Sighting and Signals SMP 31 Applicability New South Wales CRIA (NSW CRN) Primary Source RIC Standard SC 00 52 00 31 SI Version
More information