Global Product Selection Guide

Size: px
Start display at page:

Download "Global Product Selection Guide"

Transcription

1 Global Product Selection Guide

2 SELECTION GUIDE INTRODUCTION STARLINE Track Busway, Manufactured by Universal Global, is quickly becoming the industry standard in customizable power distribution. It was designed to meet the rugged specification of the UL857, IEC60439 part 1 & 2, Busway and Associated Fittings, with the flexible features of track lighting. Systems run from 100 Amp to 800 Amp with isolated protective earth. It is the simple, versatile, fast and economical solution for supplying power to electrical loads and is unique because the busway can be instantly tapped at any location, with a variety of plug-in units. This Product Selection Guide was developed to help the design engineer understand and consider all of the options available with STARLINE Track Busway when designing a system. This guide is all-inclusive; however, UGC (Universal Global Corporation) excels at collaborating with design engineers to provide solutions for any application. If you have a need that is not found in this guide, please contact us at or us at info@uecorp.com. We will be happy to answer your questions over the telephone or schedule a visit with one of our local representatives. A CD version of this guide can also be ordered free via your local STARLINE Sales Representative or by visiting Universal Global s goal is to provide you with Flexible Power Solutions no matter what your design strategy may be. We welcome any comments regarding additional material that you feel should be included to help gain a more comprehensive understanding of STARLINE Track Busway. Please direct comments to

3 TABLE OF CONTENTS SYSTEM SUBJECT PAGES GM100 GM100G / GM100NG/GM100N Standard 100 Amp / 415 Volt 100 Amp / 100% (G) or 200% (NG) Neutral / Isolated Ground/Neutral (N) GM Amp / 415 Volt GM250T5 250 Amp / 415 Volt GM Amp / 415 Volt GM Amp/415 Volt All Plug-in Units All Current Monitoring All Application Briefs All Specifications

4 Standard GM100 Amp System to 415 Volts End Piece page 1.6 Elbow page 1.3 Coupler page pole End Cap page mm Support Hardware page 1.6 Page Power Feed page mm Installation Tool Page 1.7 Tee page 1.4 Housing Section page 1.2 Accessories Closure Strip 1.6 Weight Hook 1.7 Plug-In Units pages

5 GM100 Series 100 Amps HOUSING SECTIONS Track Busway housing sections consists of an extruded aluminium shell with channel type solid copper busbars contained in a full length PVC insulator mounted on one side on the interior wall. The aluminum extrusion acts as a 100% protective earth meeting IEC The housing has an open access slot over its entire length for the insertion of turn-nlock plug-in units. The plug-in opening features finger safety to IP2X. Standard sections are 4 pole, Volt. Each housing section has male stabs protruding at one end, which fit into the channels of the adjoining section. An installation tool GM100IT is used to force the stabs into the busbar channels for a solid springtempered electrical connection. MATERIAL: Extruded Aluminum RATINGS: IEC % Protective Earth 100 Amp, Volt IP2X, IP3X with Protective Cover LENGTH: 1, 3 or 6 Metres. Custom lengths upon request VOLTAGE DROP: Distributed Load Single Phase 16.5m (.8PF) Three Phase 19m (.8PF) Catalog Number Sequence GM100 4PG (L)-415 Spring-pressure Spring-pressure channel busbar Spring-pressure Catalog Number Selection 106mm 60mm tool force (L3) (L2) (L1) Housing sections are joined by inserting male end into open female end so that stabs are parallel to female slots. Installation tool is then rotated to force stabs into slots. Refer to installation guide for procedure. Catalog No. Description Length Weight (N) Length 1, 3 or 6 Metres or Custom Length GM100-4PG GM100-4PG GM100-4PG amp, 4 pole 100 amp, 4 pole 100 amp, 4 pole 1 m 3 m 6 m 3,5 kg 11,8 kg 23,6 kg No. of Poles System size Page 1.2

6 100 Amps ELBOW SECTIONS Elbow Section Elbows are used for making a 90 degree in a busway run. Horizontal and vertical elbows are available. Specify right or left elbow according to the orientation of the busbars in the Busway sections to be connected. Refer to Layout GM100 for detail. Elbow sections are connected to adjacent Busway sections using Installation Tool GM100IT. Coupler set GMBHC-2, (ordered separately) is used to mechanically connect top and bottom of Tee section to adjacent busway. Plug-in unit cannot be inserted in elbow section open channel. 305mm 305mm Horizontal Elbow 305mm 305mm Right Elbow Left Elbow 4 254mm Male to Male Adapter - GMAD Catalog Number Sequence GMEL100 4 (X)-415 Catalog Number Selection Catalog No. Description Weight Direction Right or Left GMEL100-4-L-415 GMEL100-4-R-415 Elbow, 4 pole, left Elbow, 4 pole, right 2,5 kg 2,5 kg Number of System Poles GMAD Male to Male Adapter, 4-pole 2,5 kg Elbow Page 1.3

7 100 Amp TEE SECTIONS Tee Section Tee sections are used for creating a 90 degree branch leg in a busway run. When laying out a system, specify the correct busbar orientation of the tee. Indicate right or left, external or internal busbars. External Tees are preferred. Refer to Layout GM100 for further detail. Tee sections are connected to adjacent busway sections using Installation Tool GM100IT. Coupler set GMBHC-2 (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in tee section open channel. External Right GMT100-4-ER mm 305mm External Left GMT100-4-EL-415 Internal Right GMT100-4-IR-415 Internal Left GMT100-4-IL-415 Catalog Number Sequence GMT100-4 (XX)-415 Catalog Number Selection Catalog No. Description Weight Direction: External or Internal Right or Left GMT100-4-ER-415 GMT100-4-EL-415 GMT100-4-IR-415 GMT100-4-IL-415 Tee, 4 pole, External Right Tee, 4 pole, External Left Tee, 4 pole, Internal Right Tee, 4 pole, Internal Left 3,6 kg 3,6 kg 3,6 kg 3,6 kg Number of System Poles Tee Page 1.4

8 GM Series Amp POWER FEED UNITS Supplying Power to Busway TOP Feed / Center Feed The Top Feed Power unit comes as a completely pre-wired steel box to the top of a 760mm section of busway. A connection lug is located inside the box for field termination of supply power cable up to 50mm 2. This unit is then connected to the male end of an adjoining busway section using Installation Tool GM100IT and Housing Coupler GMBHC-2, (ordered separately). Center Feed units are similar in construction. 127mm 460mm 289mm END Feed 760mm The standard end feed consists of a steel junction box with removable side, box lugs and shrink tubing. The power feed box slips over the male end of the first busway section and secured in place with mounting studs (supplied). Power supply cable is then terminated to each of the male busway stabs using the box lugs. 204mm 102mm 254mm Installed with Couplers (GMBHC-2) Ordered Separately BOTTOM Feed A bottom feed can be made by using a 100Amp Terminal Bock plug-in unit inserted and mounted below the busway. BOTTOM Feed Using Terminal Block 165mm 318mm 88.9mm Catalog Number Sequence GM(XX) V Catalog Number Selection Catalog No. Description Weight (kg) GMEF End Feed, 4-Pole 2,72 EF= End Feed TF =Top Feed CF =Center Feed TB =Terminal Block GMTF Top Feed, 4-Pole [F F] 5,67 GMCF Center Feed, 4-Pole [M-F] 5,67 GMTB Terminal Block, 100A, 4-Pole 2,95 Page 1.5

9 GM Series Amp CONNECTION ACCESSORIES END CAP PART NUMBER GMEC For covering the female end of 100 Busway. End Piece (EP) is used to cover male end. WEIGHT 0.2 lb HOUSING COUPLERS PART NUMBER GMBHC-2 6 Connects adjacent Busway sections and/or end piece. One pair required. BHC-1 consists of two, 2-bolt couplers per set; one for the top and one for the bottom. WEIGHT 0.8 lb 2-Bolt Coupler on top 4-Bolt Coupler on bottom END PIECE PART NUMBER GMEP-2 The end piece is a 6 in. section of Busway housing, insulator and an end cap. It is used to cover the protruding copper busbar connector blades at the male end of a Busway run. An end Cap (EC) is used to cover female end. WEIGHT 0.8 lb 6 OPTIONAL CLOSURE STRIP PART NUMBER GMCS-1 - PVC GMCS-1-AL - Aluminum CUT LENGTH = 10 ft Snaps into bottom access slot of B100 housing sections. Normally shipped in 10 ft lengths and can be Page 1.6

10 GM Series Amp INSTALLATION TOOLS Used to connect two adjacent sections of Busway. Busway sections are first offset and butted together so that male stabs line up parallel to female busbar conductors. Installation tool is then inserted into joined intersection and rotated 90º forcing stabs into m-shaped female conductors making a spring-loaded, secure electrical connection. Mechanical Couplers (BHC) are then positioned over joined sections and tightened. Female Busway section Tool Pressure Male Busway section For GM100 PART NUMBER GM100IT Weight 2.5 lbs Page 1.7

11 End Piece page 1.6 Elbow page pole with Isolated Protective Earth Standard GM100G/GM100NG 100 Amp System to 415 Volts, ISOLATED PROTECTED EARTH with 100% or 200% Neutral 106 mm Support Hardware page 1.6 End Cap page 1.6 Page mm Housing Section page 2.2 Tee page 2.4 Coupler page 1.6 Power Feed page Installation Tool page 1.7 Accessories Closure Strip 1.6 Weight Hook 1.7 Plug-In Units page

12 GM100G/GM100NG Series, 100 Amps Isolated Protective Earth HOUSING SECTIONS Track Busway housing section consists of an extruded aluminum shell with spring-pressure type copper channel busbars contained in a full length PVC insulator mounted on one side on the interior wall. Center conductor acts as 100% isolated protective earth path meeting IEC The housing has an open access slot over its entire length for the insertion of turn-n-lock, plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations are 4-pole, volt. The housing sections have male stabs protruding at one end, which fit into the channels of the adjoining section. An installation tool GM225IT is used to force the stabs into the busbar channels for a solid spring-loaded electrical connection. MATERIAL: Extruded Aluminum RATINGS: 100% Isolated Protective Earth 100 Amp, 415 Volt GM100NG: 200 Amp Neutral GM100G: 100 Amp Neutral IP2X, IP3X with cover LENGTH: 1, 3 or 6 Metres. Custom lengths upon request. VOLTAGE Distributed load DROP: Single Phase 16.5m (.8PF) Three Phase 19m (.8PF). Catalog Number Sequence GM100NG 4PG (L)-415 spring pressure Spring-pressure channel busbar spring pressure Catalog Number Selection 106mm 60mm Tool Force Catalog No. Description Length Weight (L3) (L2) ISO PE (L1) (N) Housing sections are joined by inserting the male end into the open female end so that stabs are parallel to female slots. The installation tool is then rotated to force stabs into slots. Refer to installation guide for procedure. Length 1, 3 or 6 Metres or custom length GM100G-4PG GM100G-4PG GM100G-4PG A/ISO PE, 4-pole 100A/ISO PE, 4-pole 100A/ISO PE, 4-pole 1 m 3 m 6 m 4,5 kg 13,6 kg 23,3 kg Number of System Poles System size: 100G: 100% neutral 100NG: 200% neutral GM100NG-4PG GM100NG-4PG GM100NG-4PG A/ISO PE, 200%N 100A/ISO PE, 200%N 100A/ISO PE, 200%N 1 m 3 m 6 m 5,2 kg 15,4 kg 29,5 kg Page 2.2

13 GM100G/GM100NG/100 Amp Isolated Protective Earth ELBOW SECTIONS Elbow Section Elbows are used for making a 90 degree in a busway run. Horizontal and vertical elbows are available. Specify right or left elbow according to the orientation of the busbars in the busway sections to be connected. Refer to Layout GM100 for detail. Elbow sections are connected to adjacent busway sections using Installation Tool GM100IT. Coupler set GMBHC-2, (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in elbow section open channel. 305mm 305mm Horizontal Elbow 305mm 305mm Right Elbow Left Elbow Installed with couplers (ORDERED SEPARATELY) Catalog Number Sequence GMEL100NG 4 (X)-415 Direction Right or Left Number of System Poles Catalog Number Selection Catalog No. Description Weight GMEL100NG-4-L-415 GMEL100NG-4-R-415 GMEL100G-4-L-415 GMEL100G-4-R-415 Elbow, 4-pole, ISO PE, 200%N, left Elbow, 4-pole, ISO PE, 200%N, right Elbow, 4-pole, ISO PE, 200%N, left Elbow, 4-pole, ISO PE, 200%N, right 2,5 kg 2,5 kg 2,1 kg 2,1 kg Elbow System size: 100NG or 100G Page 2.3

14 GM100G/GM100NG/100 Amps Isolated Protective Earth TEE SECTIONS Tee Section Tee sections are used for creating a 90 degree branch leg in a busway run. When laying out a system, specify the correct busbar orientation of the tee. Indicate right or left, external or internal busbars. 610mm Tee sections are connected to adjacent busway sections using an installation tool GM100IT. Housing Coupler set GMBHC-2, page 7.1 (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in tee section open channel. Plug-in unit cannot be inserted in tee section open channel. External Right -ER 305mm External Left -EL Internal Right -IR Internal Left -IL Catalog Number Sequence GMT100-4 (XX)-415 Catalog Number Selection Examples Catalog No. Description Weight Direction: External or Internal Right or Left Number of System Poles Tee System Size 100NG or 100G GMT100NG-4-IL-415 GMT100NG-4-EL-415 GMT100NG-4-IR-415 GMT100NG-4-ER-415 GMT100G-4-IL-415 GMT100G-4-EL-415 GMT100G-4-IR-415 GMT100G-4-ER-415 Tee, 4 pole, 200%N, Internal Left Tee, 4 pole, 200%N, External Left Tee, 4 pole, 200%N, Internal Right Tee, 4 pole, 200%N, External Right Tee, 4 pole, Internal Left Tee, 4 pole, ISO PE, External Left Tee, 4 pole, ISO PE, Internal Right Tee, 4 pole, ISO PE, External Right 4,2 kg 4,2 kg 4,2 kg 4,2 kg 4 kg 4 kg 4kg 4kg Page 2.4

15 GM100G/GM100NG/100 Amps Isolated Protective Earth END POWER FEED UNITS Supplying Power to End of Busway End Power Feed Units Standard end power feed units connect to the male end of the busway. Factory assembled unit consists of a 305mm X 406mm X 127mm steel junction box, with removable side, connected to a 305mm section of busway. It includes Phase, Neutral connection lugs and shrink tubing for wires up to 150mm 2. Chassis earth and isolated earth lugs allow wires up 67, 42mm² respectively. Units for connection to female busway ends are also available. 406mm Installed with couplers End power feed units are connected to adjacent busway sections using Installation Tool GMB225IT and Housing Coupler Set GMBHC-2 (ordered separately). 305mm 127mm Special need power feed units for confined spaces as found in mission critical data centers can also be designed and fabricated, minimum quantities required. 305mm Assembled with Busway Section Data Center custom units can also be fabricated with minimum quantities Catalog Number Sequence GMEF100NG 4-415V Catalog Number Selection Catalog No. Description Weight (kg) Number of System Poles EF =End Feed System Size: 100NG or 100G GMEF100NG GMEF100G GMEF100NG-4M-415 GMEF100G-4M-415 End Feed, 4-Pole, ISO PE, 200%N End Feed, 4-Pole, ISO PE End Feed, 4-Pole, ISO PS, 200%N, Male End End Feed, 4-Pole, ISO PE, Male End 7,6 kg 7,6 kg 7,6 kg 7,6 kg Page 2.5

16 GM100G/GM100NG/100 Amp Isolated Protective Earth POWER FEED UNITS Supplying Power to Busway Top Power Feed Units Standard Top Power Feed units connect to the top of the busway. Factory assembled units consists of a 460mm X 289mm X 127mm steel junction box, with removable top, mounted on top of a 762mm section of busway. 460mm 289mm Top Feed Power units can be on end of busway run by connecting to adjacent busway sections using Installation Tool GM225IT and Housing Coupler Set GMBHC mm Center Feed units can also be used as top power supply point anywhere along busway run by connecting to adjacent busway sections at both ends. 762mm Installed with Couplers (GMBHC-2) Ordered Separately Catalog Number Sequence GM(XX)100NG (P)-415V Number of System Poles TF =Top Feed CF =Center Feed Catalog Number Selection Catalog No. GMTF100NG GMTF100G GMCF100NG GMCF100G Description Top Feed, 4-Pole, 200%N, ISO PE [F-F] Top Feed, 4-Pole, ISO PE, [F-F] Center Feed, 4-Pole, 200%N, ISO PE, [M-F] Center Feed, 4-Pole, ISO PE [M-F] Weight (kg) 7,48 kg 9,07 kg Page 2.6

17 GM225, 225 Amp System, 415 Volts End Piece page 1.6 Elbow page pole 106 mm Support Hardware page 1.6 End Cap page 1.6 Housing Section page 3.2 Page 3.1a 60 mm Tee page 3.4 Coupler page 1.4 Power Feed page Installation Tool page 1.7 Accessories Closure Strip 1.6 Weight Hook 1.7 Plug-In Units page

18 Protective Earth Options FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar. GM100 GM225 T5 DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential. GM100G T5G ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others. GM100G T5G Page 3.1b l

19 GM225 Series Amp HOUSING SECTIONS Track Busway housing section consists of an extruded aluminum shell with spring -pressure type copper channel busbars contained in a full length PVC insulator mounted on one side on the interior wall. The aluminum extrusion acts as a 100% protective earth meeting IEC The housing has an open access slot over its entire length for the insertion of turn-nlock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations are 4-pole, Volt rating. Each housing section has male stabs protruding at one end, which fit into the channels of the adjoining section. An installation tool GM225IT is used to force the stabs into the busbar channels for a solid spring-tempered electrical connection. MATERIAL: Extruded Aluminum RATINGS: IEC % Protective Earth 225 Amp, Volt IP2X, IP3X with Cover LENGTH: 1, 3 or 6 Metres. Custom lengths upon request VOLTAGE DROP: Distributed Load Single Phase 12.2m (.8PF) Three Phase 14.3m (.8PF) Catalog Number Sequence GM225 4PG (L)-415 No. of Poles Length 1, 3 or 6 Metres or Custom Length Spring-pressure Spring-pressure channel busbar Spring-pressure Catalog Number Selection Catalog No. Description Length Weight GM225-4PG GM225-4PG GM225-4PG mm 225 Amp, 4-pole 225 Amp, 4-pole 225 Amp, 4-pole 60mm Tool Force Housing sections are joined by inserting male end into open female end so that stabs are parallel to female slots. Installation tool is then rotated to force stabs into slots. Refer to installation guide for procedure. 1 m 3 m 6 m (L3) (L2) (L1) (N) 5 kg 15 kg 29 kg System size Page 3.2

20 225 Amps ELBOW SECTIONS Elbow Sections Elbows are used for making a 90 degree horizontal turn in a busway run. Specify right or left elbow according to the orientation of the busbars in the busway sections to be connected. Elbow sections are connected to adjacent busway sections using Installation Tool GM225IT. Coupler set GMBHC-2, (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in elbow section open channel. Horizontal Elbow 305mm 305mm 305mm 305mm Right Elbow Left Elbow Installed with couplers (ORDERED SEPARATELY) Catalog Number Sequence GMEL225-4 (X)-415 Catalog Number Selection Catalog No. Description Weight Direction Right or Left GMEL225-4-L-415 GMEL225-4-R-415 Elbow, 4-pole, left Elbow, 4-pole, right 2,5 kg 2,5 kg Number of System Poles Elbow Page 3.3

21 225 Amp TEE SECTIONS Tee Section Tee sections are used for creating a 90 degree branch leg in a busway run. When laying out a system, specify the correct busbar orientation of the tee. Indicate right or left, external or internal busbars. 610mm Tee sections are connected to adjacent busway sections using Installation Tool GM225IT. The Coupler set GMBHC-2 (ordered separately) is used to mechanically connect top and bottom of tee section to adjacent busway. Plug-in unit cannot be inserted in tee section open channel. External Right GMT225-4-ER-415 External Left GMT225-4-EL mm Internal Right GMT225-4-IR-415 Internal Left GMT225-4-IL-415 Catalog Number Sequence GMT225-4 (XX)-415 Catalog Number Selection Catalog No. Description Weight Direction: External or Internal Right or Left GMT225-4-IL-415 GMT225-4-EL-415 GMT225-4-IR-415 GMT225-4-ER-415 Tee, 4 pole, Internal Left Tee, 4 pole, External Left Tee, 4 pole, Internal Right Tee, 4 pole, External Right 9,2 kg 9,2 kg 9,2 kg 9,2 kg Number of System Poles System Size Tee Page 3.4

22 225 Amp POWER FEED UNITS Supplying Power to End of Busway End Power Feed Units Standard End Power Feed units connect to the male end of the busway. Factory assembled unit consists of a 305mm X 406mm X 127mm steel junction box, with removable sides, connected to a 305mm section of busway. It includes connection lugs and shrink tubing for wires up to 150mm 2. Ground lug connection for wires up to 67mm 2. Units for connection to female busway ends are also available. End Power Feed units are connected to adjacent busway sections using Installation Tool GM225IT and Housing Coupler Set GMBHC-2 (ordered separately). Special need power feed units for confined spaces as found in Mission Critical Data Centers can also be designed and fabricated, minimum quantities required. 406mm 127mm 305mm 305mm Assembled with Busway Section GMEF225-4M GMEF225-4 Catalog Number Sequence GMEF V Catalog Number Selection Number of System Poles Catalog No. Description Weight (kg) GMEF GMEF225-4M-415 End Feed, 4-Pole End Feed, 4-Pole, MALE END 7,48 kg 7,48 kg EF =End Feed Page 3.5

23 225 Amp POWER FEED UNITS Supplying Power at top of Busway Top Power Feed Units Standard Top Power Feed units provide connections at the top side of the busway. Factory assembled unit consists of a 460mm X 289mm X 127mm steel junction box, with removable top, mounted on top of a 762mm section of busway. 460mm 289mm Top Feed Power units can be on the end of a busway run by connecting to the adjacent busway sections using Installation Tool GM225IT and Housing Coupler Set GMBHC mm R versions reverse position of conduit KO s for easier field wiring. Center Power Feed Center Feed units can also be used as a top power supply point anywhere along a busway run by connecting to adjacent busway sections at both ends. 762mm Installed with Couplers (GMBHC-2) Ordered Separately R versions reverse position of conduit KO s (knock outs) for easier field wiring. Contact UEC for further information. Catalog Number Sequence GM(XX) V Catalog Number Selection Catalog No. Description Weight (kg) Number of System Poles GMTF GMTF225-4R-415 Top Feed, 4-Pole Top Feed, 4-Pole, Rev KO 7,48 7,48 TF =Top Feed CF =Center Feed GMCF GMCF225-4R-415 Center Feed, 4-Pole Center Feed, 4-Pole, Rev KO 9,07 9,07 Page 3.6

24 225 Amp DUAL NEUTRAL CENTER POWER FEED Dual Neutral Center Feed Standard Dual Neutral Center Feed units connect power at the top of the busway at any point along a busway run. These are used where excess neutral currents are a concern. Factory assembled units consists of a 460mm x 289mm x 127mm steel junction box, with a removable top, mounted on top of a 762mm section of busway. Dual Neutral Center Feed units can be connected between adjacent busway sections using the GM225IT Installation Tool and Coupler Set GMBHC-2. Optional Dual Lug Terminal Blocks available which facilitates daisy-chaining power supplies. R versions reverse position of conduit KO s (Knock Outs) for easier field wiring. 127mm 460mm 762mm 289mm Refer to Application Briefs for further information on Dual Neutral Center Feeds. Catalog Number Sequence GM(CF) N-(DL)-415V Catalog Number Selection System Center Feed Dual Lug (Option) Dual Neutral Number of Poles Catalog No. GMCF N-415 GMCF225-4R-2N-415 GMCF N-DL-415 GMCF225-4R-2N-DL415 Description Ctr. Feed / DBL Neutral Ctr. Feed / DBL Neutral / Rev KO Ctr. Feed / DBL Neutral / Dual Lug Ctr. Feed / DBL Neutral / Dual Lug / Rev KO Page 3.7

25 Housing Coupler page 5.8 Elbow page mm GM250T5 GM250T5NG 128 mm Standard GM250T5, GM250T5N, GM250T5NG, GM250T5G 250 Amp System, 415 Volts GM250T5NG shown 250 Amp System, 415 Volt (OVERSIZED NEUTRAL & ISOLATED PROTECTIVE EARTH) End Cap page mm 108 mm Page Power Feed page Housing Section page 4.2 Bus Connector page 4.8 Tee Page 4.4 Support Hardware page 4.7 Installation Tool page 4.8 Accessories Closure Strip 4.7 Plug-In Units page

26 Protective Earth Options FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar. GM100 GM225 T5 DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential. GM100G T5G ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others. GM100G T5G Page 4.1b l

27 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems HOUSING SECTIONS Track Busway housing sections consist of an extruded Aluminium shell with spring-pressure type copper channel busbars contained in a full length halogen-free insulator mounted on the interior walls. The Aluminium extrusion acts as a 100% protective earth meeting IEC Each housing has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations include 3 or 4-pole varieties V, optional isolated protective earth, and optional oversize (200%) neutral. The housing sections join together using Bus Connectors which fit into the channels of the adjoining section. An Installation Tool is used to force the blades into the busbar channels for a solid spring-pressure electrical connection. MATERIAL: Extruded Aluminium RATINGS: 100% Protective Earth 250 Amps GM250T5/GM250T5G 415 Volt GM250T5N/GM250T5NG 415 Volt LENGTH: 3 m OR 6 m VOLTAGE DROP: Distributed load,.8pf Single Phase 14.9 m per Volt Three Phase 17.6 m per Volt Spring pressure Spring pressure Spring-pressure channel busbar US Pat. # 6,039, mm GM250T5NG shown (L2) (L1) (PE) 108mm (L3) (N) Tool Force Housing sections are joined by inserting the Bus Connector which fits into the channels of the adjoining section. The installation tool is then rotated to force blades into slots. Catalog Number Sequence GM250T5 (X)PG (L) Length 3 or 6 Metres or custom length No. of Poles System size = 250 Amps G - Isolated PE NG - ISO PE & 200% Neutral Catalog No. Description Length Weight GM250T5-4PG A, 4-pole 3 m 18.5 kg GM250T5-4PG A, 4-pole 6 m 37 kg GM250T5G-4PG A, 4P/Iso PE 3 m 20.8 kg GM250T5G-4PG A, 4P/Iso PE 6 m 41.7 kg GM250T5N-4PG A, 4P/200%N 3 m 21.3 kg GM250T5N-4PG A, 4P/200%N 6 m 42.6 kg GM250T5NG-4PG A, 4P/ISO PE/200%N 3 m 23.1 kg GM250T5NG-4PG A, 4P/ISO PE/200%N 6 m 46.2 kg Page 5.2 l Page 4.2

28 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems ELBOW SECTION Elbow Section An Elbow is used for making a horizontal 90 degree change of direction in a Busway run. Specify right or left elbow according to the orientation of the polarizing stripe in the Busway sections to be connected. Plug-in unit cannot be inserted in elbow section open channel. CONNECTION ACCESSORIES: (Ordered Separately) Joint Kit (GMJK250T5 series) is used to make mechanical and electrical connections to adjacent Busway sections. Horizontal Elbow -R Version Shown Top View Shown Polarizing Stripe GMEL250T5-4-L Internal Elbow GMEL250T5-4-R External Elbow Elbow shown with Joint Kits installed Catalog Number Sequence GMEL250T5-(P) (X)-415 Direction (Right, Left) Number of Poles System size = 250 Amps G Isolated PE NG ISO PE & 200% Neutral Elbow Catalog No. Description Weight GMEL250T5-4-L-415 Elbow, 4-pole, left 5.9 kg GMEL250T5-4-R-415 Elbow, 4-pole, right 5.9 kg GMEL250T5G-4-L-415 Elbow, 4-pole/ISO PE, left 6.1 kg GMEL250T5G-4-R-415 Elbow, 4-pole/ISO PE, right 6.1 kg GMEL250T5N-4-L-415 Elbow, 4-pole/200%N, left 6.4 kg GMEL250T5N-4-R-415 Elbow, 4-pole/200%N, right 6.4 kg GMEL250T5NG-4-L-415 GMEL250T5NG-4-R-415 Elbow, 4-pole/ISO PE/200%N, left Elbow, 4-pole/ISO PE/200%N, right 6.6 kg 6.6 kg Page 4.3

29 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems TEE SECTION Elbow Section A Tee is used for making a horizontal 90 degree branch leg in a Busway run. Specify either internal or external, and either right or left tee according to the orientation of the polarizing stripe in the Busway sections to be connected. Plug-in unit cannot be inserted in tee section open channel. CONNECTION ACCESSORIES: (Ordered Separately) A Joint Kit (GMJK250T5 series) is used to make mechanical and electrical connections to adjacent Busway sections. Internal Right -IR Internal Left -IL Top View Shown External Right -ER External Left -EL Polarizing Stripe Catalog Number Sequence GMT250T5-(P)-(XX) Tee Direction External or Internal Right or Left No. of Poles System size = 250 Amps G Isolated PE NG ISO PE & 200% Neutral Catalog No. Description Weight GMT250T5-4-IL Tee, 4-pole, Internal Left 8.9 kg GMT250T5-4-EL Tee, 4-pole, External Left 8.9 kg GMT250T5-4-IR Tee, 4-pole, Internal Right 8.9 kg GMT250T5-4-ER Tee, 4-pole, External Right 8.9 kg Page 4.4

30 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems END POWER FEED UNITS Supplying Power to End of Busway End Power Feed Units Standard End Power Feed units connect to the end of any busway section. Factory assembled unit consists of a 305 X 406 X 165mm steel junction box with removable sides connected to a 305mm section of busway. The assembly includes connection lugs for wires up to 152mm 2. Chassis earth isolated earth allow wires up to 67mm 2 and 42mm 2 respectively. Reverse End feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from junction box end of unit). End Power Feed units are connected to adjacent Busway sections using Housing Coupler and Bus Connector which are sold separately. (Joint Kit T5 Series) Special need Power Feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 5.1b for dedicated ground application. Contact UEC representative for further information. As shown on layout dwg Assembled with 305mm of Busway Standard Reversed Catalog Number Sequence GMEF250T5 (P)(R) Reverse System Poles System size = 250 Amps G Isolated PE NG-ISO PE & 200% Neutral DG Dedicated Earth End Feed Catalog No. Description Weight GMEF250T End Feed, 4-Pole 8.0 kg GMEF250T5-4R-415 End Feed, 4-Pole/Rev 8.0 kg GMEF250T5G End Feed, 4-Pole/Iso PE 8.2 kg GMEF250T5G-4R-415 End Feed, 4-Pole/Iso PE/Rev 8.2 kg GMEF250T5N End Feed, 4-Pole/200% N 8.6 kg GMEF250T5N-4R-415 End Feed, 4-Pole/200% N/Rev 8.6 kg GMEF250T5NG End Feed, 4-Pole/ISO PE/200% N 8.9 kg GMEF250T5NG-4R-415 End Feed, 4-Pole/ISO PE/200% N/Rev 8.9 kg Page 4.5

31 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems TOP POWER FEED Supplying Power to TOP of Busway Top Power Feed Units Standard Top Power Feed units supply power from the topside of the Busway. Factory assembled unit consists of a 508 X 305 X 203 mm steel junction box, with hinged cover, mounted on top of a 914mm section of Busway. Top Feed Power units can be positioned at end or anywhere along a busway run. Connections to adjoining busway sections are made by the standard means, requiring housing couplers and bus connectors which are sold separately. (Joint Kit T5 Series) Busway Section Standard (R) Reversed Hinged side Hinged side Catalog Number Sequence GMTF250T5 (P)-415 System Poles System size = 250Amps G Isolated PE NG ISO PE & 200% Neutral Catalog No. Description Weight GMTF250T Top Feed, 4-Pole 19.1 kg GMTF250T5-4R-415 Top Feed, 4-Pole/Rev 19.1 kg GMTF250T5G Top Feed, 4-Pole/ISO PE 19.8 kg GMTF250T5G-4R-415 Top Feed, 4-Pole/ISO PE/Rev 19.8 kg GMTF250T5N Top Feed, 4-Pole/200% N 20.0 kg GMTF250T5N-4R-415 Top Feed, 4-Pole/200% N/Rev 20.0 kg GMTF250T5NG Top Feed, 4-Pole/ISO PE/200% N 20.7 kg GMTF250T5NG-4R-415 Top Feed, 4-Pole/ISO PE/200% N/Rev 20.7 kg Top Feed Page 4.6

32 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems CONNECTION ACCESSORIES END CAP For covering the end of GM250T5 Busway run. PART NUMBER GMEC250T5 WEIGHT 0.2 kg HANGER BOLTS Threaded Rod (GMBRHT5-1) For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m. Standard (GMBHT5-1) For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m. PART NUMBER GMBRHT5-1 GMBHT5-1 WEIGHT 0.5 kg. GMBRHT5-1 GMBHT5-1 ALUMINIUM /PVC CLOSURE STRIP Affixes with an adhesive backing to access slot of GM250T5 housing sections. Normally shipped in 3m lengths. PART NUMBER GMCST5-AL GMCST5-1 WEIGHT 0.67 kg/m kg/m. Page 4.7

33 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems Systems JOINT KIT/INSTALLATION TOOL JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration. 229mm HOUSING COUPLER: Consists of two, 12-screw couplers one for the top of the housing and one for the bottom. Housing Couplers are polarized with a stripe corresponding to the polarization of the housing. BUS CONNECTOR: Copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections. PART NUMBER GMJK250T5-1 GMJK250T5G-1 GMJK250T5N-1 GMJK250T5NG-1 WEIGHT 1.8 kg INSTALLATION TOOL: Used to install bus connector between two adjacent sections of Busway. Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered, and seated in the slot of the Busway joint. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into female conductors making a springpressure, secure electrical connection. Bottom housing coupler is then centered and installed. Busway Section INSTALLATION TOOL Busway section For Standard T5 Series Installation Tool Part Number Weight GMT5IT 1.4 kg Tool Pressure Page 4.8

34 Standard GM400T5, GM400T5N, GM400T5G, GM400T5NG, Amp System, 415 Volts End Cap page 5.7 Coupler page 5.7 Elbow page 5.3 GM400T5 GM400T5NG 3 or 4 pole with/without Isolated ground 128mm 128mm GM400T5NG, 400 Amp System, 415 Volt (OVERSIZED NEUTRAL & ISOLATED GROUND) 145mm 145mm Page Power Feed page Housing Section page 5.2 Tee page 5.4 Support Hardware page 5.7 Bus Connector page 5.8 Installation Tool page 5.8 Accessories Closure Strip 5.7 Plug-In Units

35 Protective Earth Options FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar. GM100 GM225 T5 DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential. GM100G T5G ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others. GM100G T5G Page 5.1b l

36 GM400T5, GM400T5N, GM400T5G, GM400T5NG System Systems HOUSING SECTION Track Busway housing sections consist of an extruded aluminium shell with spring-pressure type copper channel busbars contained in a full length Halogen Free insulator mounted on the interior walls. The aluminium extrusion acts as a 100% protective earth meeting IEC Each housing has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. The plug-in opening features finger safety to IP2X. Housing configurations include 3 or 4-pole varieties V, optional isolated protective earth, optional oversize neutral. The housing sections join together using Bus Connectors, which fit into the channels of the adjoining section. An Installation Tool is used to force the blades into the busbar channels for a solid springpressure electrical connection. MATERIAL: Extruded Aluminium RATINGS: 100% Protective Earth 400 Amps GM400T5/GM400T5G 415 Volt GM400T5N/ GM400T5NG 415 Volt LENGTH: VOLTAGE DROP: 3 or 4.5 metres Distributed load,.8pf Single Phase 14.9m per volt Three Phase 17.6m per volt Catalog Number Sequence GM400T5 (X)PG (L) spring pressure spring pressure Spring-pressure channel busbar US Pat. # 6,039,584 Catalog Number Selection 128mm Catalog No. Description Length Weight (L2) (L1) 145mm ISO PE Tool Force (L3) (N) Housing sections are joined by inserting the Bus Connector, which fits into the channels of the adjoining section. The Installation Tool is then rotated to force blades into slots. No. of Poles Length 3 or 4.5 Metres or custom length System size = 400 Amps G isolated PE NG ISO PE & 200% Neutral GM400T5-4PG GM400T5-4PG GM400T5G-4PG GM400T5G-4PG GM400T5N-4PG GM400T5N-4PG GM400T5NG-4PG GM400T5NG-4PG A, 4-pole 400A, 4-pole 400A, 4P/iso. PE 400A, 4P/iso. PE 400A, 4P/ 200%N 400A, 4P/ 200%N 400A, 4P/ISO PE/200%N 400A, 4P/ISO PE/200%N 3 m 4.5 m 3 m 4.5 m 3 m 4.5 m 3 m 4.5 m 43 kg 64.5 kg 45 kg 68 kg 50 kg 75 kg 54 kg 81.5 kg Page 5.2

37 GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems ELBOW SECTION Elbow Section An Elbow is used for making a horizontal 90 degree change of direction in a busway run. Specify right or left elbow, according to the orientation of the polarizing stripe in the busway sections to be connected. Plug-in unit cannot be inserted in elbow section open channel. CONNECTION ACCESSORIES: (Ordered Separately) Joint Kit (GMJK400 series) is used to make mechanical and electrical connections to adjacent busway sections. Horizontal Elbow GMEL400-4-L Internal Elbow GMEL400-4-R External Elbow Installed with couplers Catalog Number Sequence GMELT5400T5-(P) (X) Direction Right, Left Number of Poles System size = 400 Amps G Isolated PE NG ISO PE & 200% Neutral Elbow Catalog Number Selection Catalog No. Description Weight GMEL400T5-4-L-415 GMEL400T5-4-R-415 GMEL400T5G-4-L-415 GMEL400T5G-4-R-415 GMEL400T5N-4-L-415 GMEL400T5N-4-R-415 GMEL400T5NG-4-L-415 GMEL400T5NG-4-R-415 Elbow, 4-pole, left Elbow, 4-pole, right Elbow, 4-pole/ISO PE, left Elbow, 4-pole/ISO PE, right Elbow, 4-pole/200% N, left Elbow, 4-pole/200% N, right Elbow, 4-pole/ISO PE/200% N, left Elbow, 4-pole/ISO PE/200% N, right 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg 12,7 kg Page 5.3

38 GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems TEE SECTION Elbow Section A tee is used for making a horizontal 90 degree branch leg in a busway run. Specify internal, external, right, or left tee, according to the orientation of the polarizing stripe in the busway sections to be connected. Plug-in unit cannot be inserted in tee section open channel. CONNECTION ACCESSORIES: (Ordered Separately) A Joint Kit (GMJK400 series) is used to make mechanical and electrical connections to adjacent busway sections. 457mm 762mm Internal Right -IR Internal Left -IL Polarizing Stripe External Right -ER External Left -EL Catalog Number Sequence GMT400T5-(P) (X) Direction External or Internal Right or Left Catalog Number Selection (standard GM400 shown) Catalog No. Description Weight Number of Poles System size = 400 Amps G isolated PE NG ISO PE & 200% Neutral GMT400T5-4-IL-415 GMT400T5-4-EL-415 GMT400T5-4-IR-415 GMT400T5-4-ER-415 Tee, 4-pole, Internal Left Tee, 4-pole, External Left Tee, 4-pole, Internal Right Tee, 4-pole, External Right 19,0 kg 19,0 kg 19,0 kg 19,0 kg Tee Page 5.4

39 GM400T5, GM400T5N, GM400T5G, GM400NG Systems Disconnect Switch Power Feed Supply Power via Disconnect Switch to Busway Run Disconnect Switch Power Feed Units Standard Non-Fused Disconnect Switch Power Feed units supply power from the underside of the Busway. Busway circuit protection is provided upstream by third party switchgear. Factory assembled unit consists of a 565mm X 361mm X 205mm steel junction box, with screw mounted steel cover. Assembled disconnect switch unit is mounted underneath of a 914mm section of Busway. 914mm 205mm Disconnect Switch End Feed Power units can be positioned at end of a busway run. Connections to adjoining busway sections are made by the standard means, requiring couplers and bus connectors, which are sold separately. 400amp, 415V, 35kA 361mm 565mm Catalog Number Sequence DS400T5G Catalog Number Selection System Volts System Poles System size = 400 G isolated PE NG ISO PE & 200% Neutral Catalog No. Description Weight DS400T5G IN-LINE SWITCH 4 POLE 27.5 kg Disconnect Switch Page 5.5a

40 GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems END POWER FEED UNITS Supplying Power to End of Busway Standard End Power Feed units connect to the end of any busway section. Factory assembled units consist of a 305mm X 432mm X 254mm steel junction box, with removable sides, connected to a 305mm section of busway. The assembly includes connection lugs for wires up to 300mm 2. Chassis earth and isolated earth allow wires up to 185 mm 2 and 152 mm 2 respectively. Reverse end feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from end of unit). Junction box is sized such that one or two 103mm conduits can be installed in end of box. End Power Feed units are connected to adjacent busway sections using Housing Coupler and Bus Connector (sold separately). Special need Power Feed Units for confined spaces found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 5.1b for dedicated ground application. Contact UEC representative for further information. Assembled with 305mm of Busway As shown on layout dwg Standard Reversed Catalog Number Sequence GMEF400T5 (P)(R) Reverse System Poles Catalog Number Selection Catalog No. Description Weight System size = 400 Amps G isolated PE NG ISO PE & 150% Neutral DG Dedicated Earth End Feed GMEF400T GMEF400T5-4R-415 GMEF400T5G GMEF400T5G-4R-415 GMEF400T5N GMEF400T5N-4R-415 GMEF400T5NG GMEF400T5NG-4R-415 End Feed, 4-Pole End Feed, 4-Pole End Feed, 4-Pole/ISO PE End Feed, 4-Pole/ISO PE End Feed, 4-Pole/200% N End Feed, 4-Pole/200% N End Feed, 4-Pole/ISO PE/200% N End Feed, 4-Pole/ISO PE/200% N 14,3 kg 14,3 kg 14,5 kg 14,5 kg 15,0 kg 15,0 kg 15,2 kg 15,2 kg Page 5.5b

41 GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems TOP POWER FEED Supplying Power to TOP of Busway Top Power Feed Units Standard Top Power Feed units supply power from the topside of the Busway. Factory assembled unit consists of a 508mm X 305mm X 203mm steel junction box, with hinged cover, mounted on top of a 914mm section of Busway. 508mm 305mm Top Feed Power units can be positioned at end or anywhere along a busway run. Connections to adjoining busway sections are made by the standard means, requiring couplers and bus connectors, which are sold separately. 203mm Top Feed unit can also be used as top power supply point anywhere along Busway run by connecting to adjacent Busway sections at both ends. 914mm Busway Section Standard (R) Reversed Hinged side Hinged side Catalog Number Sequence GMTF400T5 (P)-415 System Poles Catalog Number Selection Catalog No. Description Weight System size = 400 Amps G isolated PE NG ISO PE & 200% Neutral Top Feed GMTF400T GMTF400T5-4R-415 GMTF400T5G GMTF400T5G-4R-415 GMTF400T5N GMTF400T5N-4R-415 GMTF400T5NG GMTF400T5NG-4R-415 Top Feed, 4-Pole Top Feed, 4-Pole Top Feed, 4-Pole/ISO PE Top Feed, 4-Pole/ISO PE Top Feed, 4-Pole/200% N Top Feed, 4-Pole/200% N Top Feed, 4-Pole/ISO PE/200% N Top Feed, 4-Pole/ISO PE/200% N 21 kg 21 kg 21 kg 21 kg 23,6 kg 23,6 kg 23,6 kg 23,6 kg Page 5.6

42 GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems CONNECTION ACCESSORIES END CAP For covering the end of GM400T5 busway run. PART NUMBER GMEC400T5 Weight 0,18 kg 107mm 145mm HANGER BOLTS Threaded Rod (GMBRH400T5-M12) For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the busway. Maximum hanger support spacing is every 3m. Standard (GMBH400T5-12) For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3m. PART NUMBER GMBRH400T5- M12 GMBH400T5- M12 Weight 0,45 kg GMBRH400T5-M12 GMBH400T5-M12 OPTIONAL CLOSURE STRIP (Aluminium/PVC) PART NUMBER GMCST5-AL GMCST5-1 Snaps into bottom access slot of GM400T5 housing sections. Normally shipped in 3m lengths. Weight 0,67 kg/m 0,44 kg/m Page 5.7

43 GM400T5, GM400T5N, GM400T5G, GM400T5NG Systems Accessories JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration. HOUSING COUPLER: Consists of two, 12-screw couplers- one for the top and one for the bottom. BUS CONNECTOR: Copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections. Part Number GMJK400T5-1 GMJK400T5G-1 GMJK400T5N-1 GMJK400T5NG-1 WEIGHT 1.81 Kgs Used to install the bus connector electrical joint between two adjacent sections of Busway. A Joint Kit, comprised of two housing couplers and a bus connector set are required at every joint. Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into u-shaped female conductors making a springloaded, secure electrical connection. Housing Coupler is positioned over the bottom joint and tightened. Busway Section INSTALLATION TOOL Busway section For Standard T5 Series PART NUMBER Installation Tool GMT5IT Weight 1.40 Kgs. Tool Pressure Page 5.8

44 Standard GM800T5, GM800T5G, 800 Amp System, 415 Volts Coupler page 6.8 Support Hardware page 6.6 Plug-In Units page mm Elbow page 6.4 End Cap page mm Page B800T5GCA, 800 Amp System, 600 Volt w/ Isolated Ground Power Feed page 6.5 Housing Section page Accessories Access Shutter, Closure Strip,Weight Hook Bus Connector page 6.8 Installation Tool page 6.8

45 Protective Earth Options FAQ CHASSIS EARTH, DEDICATED EARTH, ISOLATED EARTH CHASSIS EARTH Uses aluminium housing as 100% rated earth path, and no extra copper bar. GM100 GM225 T5 DEDICATED EARTH Extra bar in busway for earth. Everything tied together inside plugs. Chassis and dedicated earth bar at same potential. GM100G T5G ISOLATED EARTH 6hr receptacles position in plugs. Chassis earth isolated from copper earth bar. Isolated earth carried back to panel by others. GM100G T5G Page 6.1b l

46 GM800T5CA, GM800T5CAG Systems HOUSING SECTIONS Track Busway housing section consists of an extruded aluminium shell with a composite copperaluminum spring-pressure busbar channels contained in a full length halogen free insulator mounted on the interior walls. The enclosure provides a 100% ground path meeting IEC Standard and Section 250 of the NEC. Continuous Plug-In version has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. Plug-In Versions designated type S provide access shutters on 254 (mm) centers its entire length for the insertion of plug-in units. Housing configurations include 3 or 4 pole varieties V, optional isolated ground. The housing sections join together using Bus connectors, which fit into the channels of the adjoining section for a solid spring- pressure electrical connection. MATERIAL: Extruded Aluminium 163mm CONDUCTOR: Composite Cu/Al RATINGS: LENGTH: 100% Protective Earth (IEC ) 800 Amps 415 Volt 1.5 mtrs, 3 mtrs. 128 mm Catalog Number Sequence GM800T5CA(G)(S) (X)PG (L) 1.5 or 3 or Custom Length No. of Poles Catalog Number Selection Catalog No. GM800T5CA-4PG GM800T5CA-4PG GM800T5CAG-4PG GM800T5CAG-4PG Description 800A, Continuous Access 4P 800A, Continuous Access 4P 800A, Continuous Access 4P/ISO PE 800A, Continuous Access 4P/ISO PE Length/ Weight 1.5mtr,24kg 3mtr,47.6kg 1.5mtr,28.5kg 3mtr,57kgs Access Shutter Length 1.5 or 3 or Custom Length GM800T5CAS-4PG GM800T5CAS-4PG A, Shutter Access 4P 800A, Shutter Access 4P 1.5mtr,26.3kg 3mtr,52.1kg System Size=800Amps /CuAL G Isolated PE GM800T5CAGS-4PG GM800T5CAGS-4PG A, Shutter Access 4P/ISO PE 800A, Shutter Access 4P/ISO PE 1.5mtr,30.8kg 3mtr,61.6kg *Shutter varies depending on plug-in type/model Page 6.2

47 GM800T5CC, GM800T5CCG, GM800T5CCS, GM800T5CCGS Systems HOUSING SECTIONS Track Busway housing section consists of an extruded aluminium shell with copper spring-pressure busbar channels contained in a full length halogen free insulator mounted on the interior walls. The enclosure provides a 100% ground path meeting IEC Standard and Section 250 of the NEC. Continuous Plug- In version has a continuous access slot over its entire length for the insertion of turn-n-lock plug-in units. Plug-In Versions designated type S provide access shutters on 254 (mm) centers its entire length for the insertion of plug-in units. Housing configurations include 3 or 4 pole varieties V, optional isolated ground. The housing sections join together using Bus Connectors which fit into the channels of the adjoining section for a solid springpressure electrical connection. MATERIAL: Extruded Aluminium CONDUCTOR: Copper RATINGS: 100% Protective Earth (IEC ) 800 Amps 415 Volt LENGTH: 1.5 Mtrs, 3 mtrs. Catalog Number Selection Catalog Number Sequence GM800T5CC(G)(S) (X)PG (L)-415 No. of Poles System Size = 800/CU G Isolated PE 1.5 or 3 or Custom Length Catalog No. GM800T5CCG-4PG GM800T5CCG-4PG GM800T5CCS-4PG GM800T5CCS-4PG GM800T5CCGS-4PG GM800T5CCGS-4PG GM800T5CCGS-4PG GM800T5CCGS-4PG Description 800A, Continuous Access 4P 800A, Continuous Access 4P 800A, Continuous Access 4P/ISO PE 800A, Continuous Access 4P/ISO PE 800A, Shutter Access 4P 800A, Shutter Access 4P 800A, Shutter Access 4P/ISO PE 800A, Shutter Access 4P/ISO PE Length/ Weight 1.5mtr,43kg 3mtr,86Kg 1.5mtr,45.3kg 3mtr,90.7kg 1.5mtr,44.5kg 3mtr,89kg 1.5mtr,46.7kg 3mtr,92.8kg *Shutter varies depending on plug-in type/modle. Page 6.3

48 GM800T5 Systems HORIZONTAL ELBOW SECTIONS Elbow Section An Elbow is used for making a horizontal 90 degree change of direction in a Busway run. Specify right or left elbow, according to the orientation of the polarizing stripe in the Busway sections to be connected. Suitable for both CA and CC type busway. Plug-in unit cannot be inserted in elbow section open channel CONNECTION ACCESSORIES: (Ordered Separately) Joint Kit (GMJK800 series) is used to make mechanical and electrical connections to adjacent Busway sections. GMEL800T5-4-L Internal Elbow GMEL800T5-4-R External Elbow Catalog Number Sequence GMEL800-(P) (X) Number of Poles Direction Right, Left System size = 800 Amps G Isolated PE Catalog Number Selection Catalog No. Description Weight GMEL800T5-4-L-415 Elbow, 4-pole, left 12.7 Kgs GMEL800T5-4-R-415 Elbow, 4-pole, right 12.7 Kgs GMEL800T5G-4-L-415 Elbow, 4-pole/ISO PE, left 13.6 Kgs GMEL800T5G-4-R-415 Elbow, 4-pole/ISO PE, right 13.6 Kgs Elbow Page 6.4

49 GM800T5 Series Systems END POWER FEED UNITS Supplying power to end of Busway Standard End Power Feed units connect to the end of any busway section. Factory assembled unit consists of a 610 X 508 X 508 mm. steel junction box, with removable sides, connected to a 305mm section of busway. The assembly includes connection lugs that can handle up to (2) 300mm2 wires (CU) or (3) 300mm 2 wires (AL). Chassis earth and isolated earth allow wires up to 185mm 2. Reverse End feed units for connection to opposite end of busway section (polarizing stripe faces to right as viewed from end of unit) Junction box is sized such that one or two 100mm conduits can be installed in end of box. 508 End Power Feed units are connected to adjacent Busway sections using Housing Coupler and bus connector (sold separately). 305mm SECTION OF BUSWAY Special need power feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. Reference page 6.1b for dedicated earth application. Contact UEC representative for further information. Catalog Number Sequence GMEF800T5 (P)(R) Reverse System Poles System size = 800 amp G Isolated Ground DG Dedicated Ground Catalog Number Selection Catalog No. Description Weight GMEF800T End Feed, 4-Pole 14.2 Kgs GMEF800T5-4R-415 End Feed, 4-Pole / Rev 14.2 Kgs GMEF800T5G End Feed, 4-Pole / ISO PE 14.5 Kgs GMEF800T5G-4R-415 End Feed, 4-Pole / ISO / Rev 14.5 Kgs End Feed Page 6.5

50 GM800T5 Series Systems CENTER POWER FEED UNITS Supplying power to center of Busway Center Power Feed unit connects between adjacent busway sections to provide power in the center of a busway run. Factory assembled unit consists of a 610 X 508 X 762mm. steel junction box, with removable sides, connected to two 305 mm sections of busway. The assembly includes connection lugs that can handle up to (2) 300mm 2 MCM wires (CU) or (3) 300mm 2 wires (AL). Chassis earth and isolated earth allow wires up to 185mm mm 762mm Junction box is sized such that one or two 100mm conduits can be installed in end of box. Center Power Feed units are connected to adjacent Busway sections using Housing Coupler and bus connector (sold separately). 508mm 610mm Special need power feed units for confined spaces as might be found in Mission Critical Data Centers can also be designed and fabricated, requiring minimum quantities. POLARIZED STRIPE Catalog Number Sequence GMCF800T5(X) (P) System Poles Catalog Number Selection Catalog No. Description Weight GMCF800T Ctr Feed, 4-Pole 14.2 Kgs GMCF800T5G Ctr Feed, 4-Pole/ISO PE 14.5 Kgs System size = 800 amps G ISO Protective Earth Center Feed Page 6.6

51 GM800T5 Systems CONNECTION ACCESSORIES END CAP For covering the end of GM800T5 Busway run. PART NUMBER GMEC800T5 WEIGHT Kgs. HANGER BOLTS Threaded Rod (GMBRHT5- M12) For mounting to M12 threaded rod. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3 meters. Standard (GMBHT5-M12) For mounting to strut or other flat surfaces. Twist-in design. Can be inserted anywhere along the full access slot on the top of the Busway. Maximum hanger support spacing is every 3 meters. PART NUMBER GMBRHT5-M12 GMBHT5-M12 WEIGHT.453 Kgs. BRHT5-1 BHT5-1 OPTIONAL CLOSURE STRIP (Aluminium/PVC) Snaps into bottom access slot of GM800T5 housing sections. Normally shipped in 3 meters lengths. PART NUMBER GMCST5-AL GMCST5-1 WEIGHT 0.67 kg/m 0.44 kg/m Page 6.7

52 GM800T5 Systems Systems JOINT KIT/INSTALLATION TOOL JOINT KIT For connection of adjacent Busway sections. One Kit required at each joint. Each Kit is comprised of a housing coupler pair and bus connector set. Specify configuration to match busway configuration. HOUSING COUPLER: Consists of two, 12-screw couplers- one for the top and one for the bottom. BUS CONNECTOR: Silver plated copper blades secured to insulating mounting plate. Left and Right set, makes electrical connection between sections. PART NUMBER GMJK800T5-1 GMJK800T5G-1 WEIGHT 1.81 Kgs. INSTALLATION TOOL Used to install the bus connector electrical joint between two adjacent sections of Busway. A Joint Kit, comprised of two housing couplers and a bus connector set are required at every joint. Busway sections are butted together and the top housing coupler is installed. The Bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90º forcing stabs into u-shaped female conductors making a springloaded, secure electrical connection. Housing Coupler is positioned over the bottom joint and tightened. Installation Tool For T5 Series PART NUMBER INSTALLATION TOOL GMT5IT Weight 1.40 Kgs. Page 6.8

53 PLUG-IN UNITS Table of Contents GM100/GM100G/GM100NG/GM225/ GM400/GM400G/GM400N/GM400NG/GM800 E28 Circuit Breaker Unit Page 7.2 E28 Socket Units Page 7.3 E28 Drop Cord Units Page 7.4 E25 Socket Units Page 7.5 E25 Hybrid Units Page 7.6 E40 Circuit Breaker Drop Cord Page 7.7 E40 Circuit Breaker Page 7.8 E40 Circuit Breaker Socket Page 7.9 E50 Circuit Breaker Drop Cord Page 7.10 E70 Circuit Breaker Page 7.11 E90 Circuit Breaker Page 7.12 Monitoring Page 8.1 Page 7.1

54 100, 225, 400 Amp GM100, GM100G, GM100NG, GM225, GMT5, GMT5G, GMT5N, GMT5NG E28 CIRCUIT BREAKER PLUG-IN Basic MCB unit used to tap off power from the busway. Plug head is reversible to face in opposite direction. Capable to 7 MCB pole positions. 100/225 Plughead MCB s are factory installed to internal DIN rail. D-curve MCBs supplied unless trip curve is specified. Consult factory for possible combinations. Maximum ratings of 100 total amps, V, Hz, 10K Ipk (Higher Ipk upon request). IP3X GMT5 Series plug-head Requires 235mm slot space Locks into position with a single bolt on mounting tab. Normal position, breaker faces busway conductor side Catalog Number Sequence GMCB***E28-aa-y-xxx Voltage Enclosure conductor stab assembly can be rotated (in the field) to face opposite side. Circuit breaker(s), and (p/aa-y) Single MCB aa=amps y=mcb poles, 1-4 Enclosure Multiple MCB s p=mcb poles, 1-4 aa=amps y=total poles, 1-7 System Size, 100, 100G, 100NG, 225, Circuit Breaker GMT5, GMT5G, GMT5N, GMT5NG Page 7.2

55 100, 225 T5 Series Amp GM100, GM100G, GM100NG, GM225, GMT5, GMT5G, GMT5N, GMT5NG E28 CIRCUIT BREAKER SOCKET PLUG-IN MCB unit with sockets or receptacles, used to tap off power from the Busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible to face in opposite direction. Capable to 7 MCB pole positions. Capable to 2 or more sockets. (Consult factory for possible combinations.) D-curve MCBs supplied unless trip curve is specified Maximum ratings of 100 total amps, V, Hz, 10K Ipk (Higher Ipk upon request) IP3X Requires 235mm slot space. Locks into position with a single bolt on mounting tab. Normal position, breaker faces busway conductor side Catalog Number Sequence GMCB***E28-(SOCKET) Enclosure conductor stab assembly can be rotated (in the field) to face opposite side. Wiring Device, ref. via IEC page 9.6 Enclosure System Size, 100,100G,100NG, 225, GMT5, GMT5G, GMT5N, GMT5NG Circuit Breaker Page 7.3

56 100, 225, T5 Series Amp GM100, GM100G, GM100NG, GM225, GMT5, GMT5G, GMT5N, GMT5NG E28 CIRCUIT BREAKER DROP CORD PLUG-IN MCB unit with drop cords used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully-assembled. Plug head is reversible to face in opposite direction. Capable to 7 MCB pole positions. Capable to 3 drop cords. Consult factory for possible combinations and cord lengths D-curve MCBs supplied unless trip curve is specified. Maximum ratings of 100 total amps, V, 50 60Hz, 10K Ipk (Higher Ipk upon request). IP3X Requires 235mm slot space. Locks into position with a single bolt on mounting tab. Normal position, breaker faces busway conductor side Catalog Number Sequence GMCBDC***E28-X-(CONNECTOR) Enclosure conductor stab assembly can be rotated (in the field) to face opposite side. Wiring Device Cord Length in meters Enclosure System Size, 100,100G,100NG, 225, GMT5, GMT5G, GMT5N, GMT5NG Circuit Breaker/Drop Cord Page 7.4

57 100, 225, T5 Series Amp GM100, GM100G, GM100NG, GM225, GMT5, GMT5G, GMT5N, GMT5NG E25 CIRCUIT BREAKER PLUG-IN Versatile MCB unit with sockets or receptacles, used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible to face in opposite direction. Capable to 8 MCB pole positions. Capable to 3 or more sockets. (Consult factory for possible combinations.) D-curve MCBs supplied unless trip curve is specified Maximum ratings of 100 total amps, V, Hz, 10K Ipk (Higher Ipk upon request). IP3X Requires 450mm slot space. Locks into position with two bolts. Catalog Number Sequence GMCB(sys)E25-(socket) Socket Configuration Ref. page 9.6 System Size 100, 100G, 100NG, 225, 225G Circuit Breaker Catalog Number Selection Catalog No. Description Weight GMCB225E25-(2)W26424-(2)332A6S GMCB225E25-(3)332A6S/2P GMCB400E25-(2)532A6S-4 (2)32A/3wire/230V Socket w/ 1P MCB & (2)W26424 (3) 32A/3wire/230V Sockets, (3)2P MCB s (2) 32A/5wire/415V, Sockets, (2)3P MCB s 5,44 kg 5,44 kg 5,44 kg Page 7.5

58 100, 225, T5 Series Amp GM100, GM100G, GM100NG, GM225, GMT5, GMT5G, GMT5N, GMT5NG E25 HYBRID PLUG-IN Versatile MCB unit can be customized by factory with sockets or receptacles, and drop cords. A wide variety of device combinations are possible. Units are shipped fully assembled. Plug head is reversible to face in opposite direction. Capable to 8 MCB pole positions. Capable to 3 or more sockets and up to 3 drop cords. (Consult factory for possible combinations.) D-curve MCBs supplied unless trip curve is specified. Maximum ratings of 100 total amps, V, Hz, 10K Ipk (Higher Ipk upon request). IP3X Requires 450 mm slot space. Locks into position with two bolts. Consult factory to specify devices, configuration and ordering information. Page 7.6

59 T5 System Plugs E40 CIRCUIT BREAKER DROP CORD PLUG-IN Premium engineered MCB unit with drop cords used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully-assembled. Plug head is reversible to face in opposite direction. Compatible with all T5 busway systems. Provides multiple MCB pole positions by adjusting unit length. Capable to 3 or more drop cords. Consult factory for possible combinations and cord lengths D-curve MCBs supplied unless trip curve is specified. Maximum ratings of 125 total amps, V, 50 60Hz, 10K Ipk (Higher Ipk upon request). IP3X Locks into position with a single bolt on mounting tab. Normal position, breaker faces busway conductor side Enclosure conductor stab assembly can be rotated (in the field) to face opposite side. Catalog Number Sequence GMCBDCT5E28-X-(CONNECTOR) Wiring Device Cord Length in metres Enclosure System Size: T5. Add G or NG as required Circuit Breaker/Drop Cord Page 7.7

60 T5 System Plugs E40 CIRCUIT BREAKER PLUG-IN Premium engineered unit that combines style with versatility. Designed to tap off power from the busway. Compatible with all T5 busway systems. Plug head is reversible to face in opposite direction. Provides multiple MCB pole positions by adjusting unit length. 178 MCB s are factory installed to internal DIN rail. D-curve MCBs supplied unless trip curve is specified. 356 Consult factory for possible combinations. 127 Maximum ratings of 125 total amps, V, Hz, 10K Ipk (Higher Ipk upon request). IP3X GMT5 Series plug-head Locks into position with a single bolt on mounting tab. Normal position, breaker faces busway conductor side Enclosure conductor stab assembly can be rotated (in the field) to Catalog Number Sequence GMCBT5E48-aa-y-xxx Voltage Circuit breaker(s), and (p/aa-y) Single MCB aa=amps y=mcb poles, 1-4 Enclosure Multiple MCB s p=mcb poles, 1-4 aa=amps y=total poles, 1-7 System Size: T5. Add G or NG as required Circuit Breaker Page 7.8

61 T5 System Plugs E40 CIRCUIT BREAKER SOCKET PLUG-IN Premium engineered MCB unit with sockets or receptacles, used to tap off power from the Busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible to face in opposite direction. Compatible with all T5 busway systems. Provides multiple MCB pole positions by adjusting unit length. Capable to 2 or more sockets. (Consult factory for possible combinations.) D-curve MCBs supplied unless trip curve is specified 178 Maximum ratings of 125 total amps, V, Hz, 10K Ipk (Higher Ipk upon request) IP3X 356 Locks into position with a single bolt on mounting tab. Normal position, breaker faces busway conductor side Enclosure conductor stab assembly can be rotated (in the field) to face opposite side. Catalog Number Sequence GMCBT5E40-(SOCKET) Enclosure Wiring Device, ref. page 9.6 System Size: T5 or T5G Circuit Breaker Page 7.9

62 Next-generation, custom engineered enclosure that features a stylish exterior combined with a spacious interior and customizable body length to accommodate a wide variety of applications. The E50-Series enclosure is designed to tap off power from the busway and is compatible with all T5 systems. The option is available to have a reverse T5 Paddle such that the enclosure faces in the opposite direction when in the busway. T5 Series Plug-Ins GM250T5, GM400T5, GM800T5 SYSTEMS E50 ENCLOSURE Circuit Breaker Applications Configurable unit length for multiple circuit breaker pole positions. Locks easily and quickly into position using a no tooling latching mechanism Model Shown: GMCBT5GE56-(4)332A6S/2P Maximum rating of 35kA at 480V Consult factory for possible combinations* T5 Paddle (Standard Orientation, Reverse option available) Enclosure Lengths (Please consult factory for proper sizing) E51 156mm (6.14 ) E52 207mm (8.14 ) E53 258mm (10.14 ) E54 309mm (12.14 ) E55 334mm (13.14 ) E56 386mm (15.14 ) E57 461mm (18.14 ) Latching Mechanism (No tooling install) Catalog Number Sequence GM CB [DC] T5 (G) (H) E 5 x [L] - (X)(Wiring Device) Global Metric (Circuit Breaker) (Drop Cord) Isolated Earth High- Interrupt Rating Enclosure* 1 through 7 (Device qty) Length of Drop Cord (Meters) e.g IEC309 Single/Three Phase Device Amps Angled / Straight Receptacle / Connector Splashproof /Watertight Page

63 100, 225, T5 System Plugs E70 CICUIT BREAKER PLUG-IN Premium engineered MCB unit, ideally suited where physical space is limited whilst providing high density power distribution. Used to tap off power from the busway with a wide variety of device configurations. Units are shipped fully assembled. Plug head is reversible. Available for both single & three phase. Available options for drop cord connector termination, surface mount receptacles or a combination of both. (Consult factory for possible combinations.) D-curve MCBs supplied unless trip curve is specified. Maximum ratings of 125 total amps, V, Hz, 10KA Ipk (Higher Ipk upon request). Metering options available. Consult factory for metering options. IP3X GM225 Requires 195mm slot, GMT5 requires 220mm width space within busway bolt. Drop Cord Catalog Number Sequence GMCBDC(sys)E70-X-(CONNECTOR) Connector Configuration Cord Length in meters Enclosure System Size 100, 225amp, T5 series. Add G as required. Circuit Breaker/Drop Cord Receptacle Catalog Number Sequence GMCB(sys)E70-(SOCKET) Socket Configuration Enclosure System Size 100, 225amp, T5 series. Add G as required. Circuit Breaker Page

64 100, 225 Amp Plug-Ins GM100, GM225 SYSTEMS Next-generation, custom engineered enclosure that features a stylish exterior combined with a spacious interior and customizable body length to accommodate a wide variety of applications. The E90-Series enclosure is designed to tap off power from the busway. The option is available to have a reverse paddle such that the enclosure faces in the opposite direction when in the busway. E90 ENCLOSURE Circuit Breaker Applications Configurable unit length for multiple circuit breaker pole positions. Locks into position using a single, easy access bolt Maximum rating of 22kA at 480V for GM100, 22kA at 240V for GM225 Model Shown: GMCB225E93-332A6S/2P-FS Consult factory for possible combinations* Enclosure Lengths (Please consult factory for proper sizing) 225 Paddle (Standard Orientation, Reverse option available) E91 152mm (6.00 ) E92 203mm (8.00 ) E93 254mm (10.00 ) E94 305mm (12.00 ) E95 330mm (13.00 ) E96 381mm (15.00 ) E97 457mm (18.00 ) Catalog Number Sequence GM CB [DC] 225 (G) (H) E 9 x [L] (X)(Wiring Device) Easy Access Bolt Global Metric Circuit Breaker (Drop Cord) Isolated Earth High- Interrupt Rating Enclosure* 1 through 7 (Device qty) e.g IEC309 Single/Three Phase Device Amps Length of Drop Cord (Meters) Angled / Straight Receptacle / Connector Splashproof /Watertight Page

65 RECEPTACLE DESIGNATION CATALOG NUMBER SYSTEM MONITORING Catalog Number Selection Socket units and drop cord units GMCBDCT5E28G-X-(2)532C6W IP Type (Ingress Protection) Ground (Earth) position Connector Body First & second wiring device Number of cord sets for first wiring device Cord length metric Isolated Protective earth Enclosure (240V) T5 System Drop cord Circuit breaker protection Global Metric GMCBT5E36-532A6S IP Type (Ingress protection) Receptacle Body Wiring device Enclosure (415V) T5 System Circuit breaker protection Global Metric Page 8.6

66 CIRCUIT BREAKER UNIT FOR BRANCH CIRCUIT MONITORING Circuit Breaker Unit with Installed Critical Power Monitor The Branch Circuit Current Monitoring Unit has the capability of monitoring a maximum of 4 single phase receptacles or a one 3-phase receptacle. The monitor has 4 channels available. Solid core current transformers (CT) are installed around the phase wires in the plug-in unit. R versions provide remote communication functions and DR provide remote display and remote communications. Communications Ethernet and Modbus RTU ports are standard. Ethernet port provides an Embedded Web (html) Interface & supports SNMP. See Power Monitoring pages for more details. Catalog No. GMCB225E28-(2)316A6S-M20R16/2 GMCBT5GE28-532A6S-M20R32/3 GMCBT5GE28-332A6S-M20R32/2 GMCBT5GE25-(2)520A6S-(2)M20R20/3 GMCBDC225GE25-X-(2)516C6S-(2)M20R16/3 Description CKT. BKR. UNIT W/RECEPTS (2)316A6S CKT. BKR. UNIT W/RECEPTS 532A6S CKT. BKR. UNIT W/RECEPTS 332A6S CKT. BKR. UNIT W/RECEPTS (2)520A6S CKT. BKR. DROP CORD UNIT W/CONN BODY- (2)516C6S Page 8.5

67 CRITICAL POWER MONITORING M41/M43/M45/M47 DETAILS The Starline Critical Power Monitor (CPM) is a distributed data acquisition system that enables current and power monitoring in busway systems. Each phase and neutral can be monitored independently. The CPM may be incorporated at a power feed point or directly into a plug-in unit. CURRENT TRANSFORMERS: Current transformers (CT s) are supplied with the unit for installation onto the customersupplied feeder cables. Sense leads from the CT s connect to the Meter. METER MODULES: Each unit is calibrated for accuracy and is within 0.5% to meet ANSI Revenue Grade Standards. CPM ENHANCED PACKAGE (M41/M43/M45/M47): Provides current and voltage inputs, monitoring current, voltage, power, power factor, frequency, apparent power, energy kwh, reactive power, neutral current, power min. and max. DISPLAY: The bright, 4.9 LCD reports basic power measurements and alarms. Display buttons provide configuration and direct control to the active display screen. Large format display is easily readable at a distance and wide viewing angle. COMMUNICATION: Ethernet and Modbus RTU ports are standard. Ethernet port provides an embedded web (HTTP) Interface & supports SNMP. Wi-Fi interface is optional, providing true versatility in the busway environment. ALARMS: When the defined alarm threshold is exceeded, a warning corresponding to that channel will turn ON and send an SNMP trap or an to the user. Critical Power Monitor with the (optional) 4.9 Display Critical Power Monitor (No Display) The Critical Power Monitor can be used to manage and maximize power distribution within a three phase power system. It can be employed as a component to help balance three phase power distribution between each phase. This increases efficiency by reducing the power factor and enables a user to fully analyze the power supplied to them. POWER FEED MONITORING The CPM, incorporated in or near the power feed unit, provides load monitoring of the entire run of busway. These are used in conjunction with BMS systems to ensure busway is not overloaded as well as for general power management. Typically uses the CPM unit with display. BRANCH CIRCUIT MONITORING The CPM, incorporated into a plug-in unit, monitors individual branch circuits. These units are used in conjunction with BMS system for power management and revenue purposes at the rack or circuit level. The CPM is capable of monitoring the entire unit or monitoring up to 4 individual devices, limited to 6 solid core Current Transformers (CTs). BUILDING MANAGEMENT INTERFACE The Starline CPM is easily interfaced with BMS/BCIM systems. Many BMS/BCIM systems offer drivers for use with the Starline CPM. Contact your BMS/BCIM supplier or Starline Engineering for more information. Page 8.6 l

68 Application Briefs FREQUENTLY ASKED QUESTIONS 1. Can you have isolated ground? Yes On our 100A, 225A, 250A, 400A and 800A versions we can add a fifth copper bar rated at 100% capacity ground. The product types are GM100G, GM100NG, GM225G, GM250T5G, GM400T5G, GM400T5NG and GM800T5G. 2. How do you keep people from adding too many drops and overloading the circuit? STARLINE Track Busway is no different from any other busway or panelboard. Anyone could mount 14-3 pole 100A circuit breakers in a 225A main panel if they wanted to. It is typical that the addition of a circuit to STARLINE is done by a qualified person who is familiar with the electrical system at the facility. They are expected to know the load on the bus through routine sampling over time. However, for those who want protection against this issue, we have developed a product called Bus Run Monitor. This product installs in the busway slot and includes 3 CTs that are installed in an end feed unit. Bus Run Monitor has an optional warning light, warning buzzer, or form C contacts to notify facility personnel of a current draw over the preset limit. The preset can be selected at 60-90% of the bus capacity. We believe this is a valid concern but in practice STARLINE Track Busway trips have been extremely rare. 3. How do you identify Phase L1, L2, or L3 device on the power drop boxes? Each drop box carries a number label either L1, L2, or L3. The color code is determined by the customer s request. If the customer has no preference, we typically ship 1/3 of the drop boxes wired to each individual phase. 4. How do you know what phase you are plugged into, and how do you allocate the drops so they are balanced across all three phases? Answer 3 addresses the first half of this question. The answer to the second half is the same as any power distribution system. The electrical designer does the balancing. Page 9.1

69 Application Briefs WALL MOUNTING GM100/GM100NG/GM225 SYSTEMS Wall A To properly position busway at the minimum distance from wall, first select the largest plug-in unit to be used with the system. Using the provided table as a reference, find the distance (A) to position the busway from the wall. Position the busway and secure into place by tightening the BH- M10 hanger. ENCLOSURE A WIDTH 101 mm to 203 mm 101 mm 215 Top mm view to of large 241 Circuit mm Breaker 127 mm Plug-In shown 266 mm & Up 203 mm Busway Conductor side GMBH-1 Standard Hanger initial insert position If a plug-in unit does interfere with the wall, loosen all hanger bolts and move the Busway slightly to allow the plug-in unit to rotate into its final resting position. Ensure that the Busway sections are adjusted evenly to avoid any kinking of Busway section joints. Minimum distance from mounting edge surface to enclosure occurs as enclosure edge is in line with rotation center-line of paddle Loosed GMBH-1 & reposition Busway if enclosure is too close to wall as needed. 3 M. Max. Equal Busway Rotate to install Equal Page 9.2

70 Application Briefs WALL MOUNTING GM100/GM100N/GM100NG, & GM225 SYSTEMS Busway plug-in units face toward the conductor side (with the exception of the E9 or S enclosure). When installing the busway along a wall, care should be taken to make sure the busway conductor side faces away from the wall. Power End Feed Wall Busway NOTE: Be careful when ordering plug-in units with the busway conductors facing the wall, some plug-in units will have receptacles or breakers facing the wall. Consult the Product Selection Guide to ensure plug-in units selected will face the desired direction. Top view of Circuit Breaker Plug-In shown Profile of GM225 Busway (GM100,GM100NG are similar profiles) Loosen THB-3 & position Busway if enclosure is too close initial to insert wall, as needed. position Conductor side Polarizing Lip Minimum distance from mounting surface to enclosure occurs as enclosure edge is in line with rotation centerline of paddle. Wall Mounting bolts Using MO bolts, mount the short leg of the mounting bracket to your wall/surface (Note: use appropriate bolt type for type of wall/surface. Ensure that the bracket is mounted securely enough to support the weight of the busway and any anticipated plug-in units (maximum allowable weight is 45kg between mounting supports). Space the brackets no more than 3 meters on center. BH-1 Standard Hanger Busway 3 m Max. Page 9.3

71 Application Briefs 225 AMP WITH 200% NEUTRAL In certain applications, it is necessary to have a 200% rated neutral. Harmonic currents generated by electronic loads create a neutral current that may approach twice that of the phase currents. For 100 amp applications, STARLINE Track Busway offers a 100 Amp rated busway with a 200% rated neutral for this purpose. For 225 Amp applications, STARLINE Track Busway offers a power feed unit with a dual neutral connection for achieving a 225 Amp rated system with two, independent 225 Amp rated neutrals. In essence, the busway system provides 225 Amps per phase with 200% neutral capacity. Dual Neutral Center Feed Power feeds to a busway system are typically located at the end of the busway system runs, but may be located at any point on the run. A power feed at some intermediate point on the run is called a Center Feed. In many cases, the center feed is used so that the power tap to the busway can be located at a point convenient for the feeder cable home run. The dual neutral center feed is located at the center of a run and takes advantage of the distributed loads typical in busway applications. Figure 1 shows a traditional busway application in a data center. An end power feed provides power to a series of racks. Racks are evenly spaced, and the load is more or less evenly distributed along the length of the busway. The busway phase and neutral ratings are 225 Amps maximum. Page 9.4

72 Application Briefs Figure 2 shows the same busway application with the dual neutral center feed. The dual neutral center feed electrically separates the neutral busbar into two circuits. The dual neutral circuits feed the busway in opposite directions. Figure 3 shows the electrical schematic for the dual neutral power feed unit. As can be seen, the neutral busbar is divided in two, and electrically isolated in the center, thereby provided two, independent neutral circuits. Separate terminal block connections are provided for each neutral feed. Three phase connections and an isolated ground (optional) connection are provided in the normal manner. Page 9.5

73 Application Briefs 225 AMP WITH 200% NEUTRAL Refer again to Figure 2. The system is capable of a total of 225 Amps per phase across the entire system length. More importantly, the system is capable of 225 Amps neutral current to the left of the power feed, and another 225 Amps neutral current to the right of the power feed. The end result is that with a single power feed point and therefore a single conduit home run, the busway system provides 225 Amps per phase and 450 Amps neutral capacity. Features Single power feed point System rated for 225 Amps per phase System rated for 450 Amps neutral current Compatible with all STARLINE GM225 and GM100NG (isolated ground) plug-in units. Cost efficient double neutral system Page 9.6

74 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems COMPONENT RELATIONSHIP When ordering material it is important to understand the relationship between various components. Examples: GM250T5 uses the T5 series of plug-in units. These plugs are interchangeable with GM400T5 plugs and compatible with other Starline T5series busway systems. ALL COMPONENTS except Housing, Tee, Elbow Sections and Power Feeds are the same and are interchangeable for GM250T5, GM250T5N (double neutral), GM250T5G and GM250T5NG Amp Systems. Substitute either GM250T5 or GM250T5N or GM250T5G or GM250T5NG for all Housing, Tee, Elbow Sections and Power Feed units. Each housing section requires a joint kit. Determine the total number of housing sections (regardless of length) as this becomes the number of Joint Kits (GMJK250T5 series) that will be needed. o o Add one extra Joint Kit for each Tee Section. No need to add extra Joint Kits for Elbow Sections, as they are already part of your housing count. If this is your first installation for either GM250T5, GM250T5N, GM250T5G or GM250T5NG systems, you will need to order Installation Tool GMT5IT. General support hardware rule to follow: Total System Length (10%) = Support Hardware Qty equal 3 m spacing and 10% extra is recommended for job site changes. Total Power Feeds and End Caps can be determined by counting the total number of unconnected runs. Before specifying or ordering elbow or tee sections, it is important to understand polarity and the relationship to direction of outlets. Please refer to POLARITY CONCERNS for more detail. Page 9.7

75 GM250T5, GM250T5N, GM250T5G, GM250T5NG Systems POLARITY CONCERNS STARLINE utilizes a unique polarizing method to prevent mismatched components from being inadvertently connected to each other. The system is designed to prevent cross phasing during installation. It is particularly important to understand this design concept prior to ordering and/or installing some components. For example, if the face direction of a STARLINE plug-in unit is important in your installation consider that they will always face the conductor side. Certain plug-in units are reversible, designated by R, to face devices away from the conductor side. Top View Outlet Box always faces polarizing stripe Stripe side Outlet Box always faces polarizing stripe Polarizing Stripe Tee s and Elbow Sections are specified according to desired polarity Power Feed Outlets Facing Outlets Facing Outlets Facing Outlets Facing Outlets Facing Outlets Facing Page 9.8

76 Application Briefs NEUTRAL SIZING-400 AMP SYSTEMS In certain applications, a customer may want the safeguard of a neutral conductor rated at more than 100% of the phase conductors. For 400 amp applications, STARLINE Track Busway offers a busway system with an oversized neutral busbar. The rating of the oversized neutral is 150% of a 400 Amp phase that is protected by an 80% rated circuit breaker. Thereby a neutral capacity of 480 Amps is achieved. This supplies the customer with 160 Amps of additional capacity on the neutral conductor compared to the maximum phase current. Why Oversized Neutral? There is a concern that with a 3-phase, 4-wire, wye-connected system with nonlinear loads, the neutral may need to carry more than the system s rated full-load current. According to a IEC report on nonlinear loads, in certain instances the neutral conductor current will exceed 100% but will rarely exceed 125% of the rated full-load current. This report can be seen in the 2005 IEC Handbook, IEC article (B) 4. To cover the majority of applications, the GM400N system was tested and certified with a neutral rating of 150% of the phase current, with the assumption that the phases are protected with an 80% circuit breaker. 400 Amps (Phase) x 80% (System Protection Breaker) = 320 Amps (Full Load Phase Current) 320 Amps (Full Load Phase Current) x 150% (Oversized Neutral Rating) = 480 Amps (Full Load Neutral Current) The System GM400N and GM400NG System contain all of the features of the standard B400 and B400G systems plus an oversized neutral busbar. This busbar doubles the amount of copper for the neutral in a Busway section. Oversized neutral end feeds are supplied with a double lug for the neutral. The customer will be able to connect to the neutral with two 120 mm2 wires. All other connections have a single wire entry. The maximum voltage rating for the GM400N/GM400NG system is 277Y / 415 volts. The oversized neutral Busway system uses all of the same hardware, plug in units and accessories as the standard GM400 system uses. Nomenclature GM400N GM400NG GMEF400N GMEF400NG GMJK400N-1 GMJK400NG-1 400A Busway Section with oversized neutral 400A Busway Section with oversized neutral and protected Earth 400A End Feed with oversized neutral 400A End Feed with oversized neutral and protected Earth 400A Jointer Kit with oversized neutral 400A Jointer Kit with oversized neutral and protected Earth Page 9.9

77 SECTION TRACK BUSWAY SYSTEM 1.01 SUMMARY A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway STANDARDS AND CERTIFICATION A. The Track Busway shall be designed and manufactured to the following standards. 1. Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 2. Low Voltage Switchgear and Control gear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC : Low Voltage Switchgear and Control gear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC : Underwriters Laboratories Standard, UL 857 The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelve edition of UL 857, and the second edition of NMX-J ANCE. 5. CUL Listing 6. National Electric Code (NEC) Article 364 Busways 7. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 8. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC) SYSTEM DESCRIPTION A. Electrical Requirements STARLINE TRACK BUSWAY Manufactured by Universal Electric Corp. 168 Georgetown Road Canonsburg, PA Phone # (724) Voltage 240/415V Frequency: Ampacity: Neutral Ampacity: Conductors: and Neutral). Earth: System Designation: 50/60 Hz 100A /225 A 225 A Qty 4 (Phases L1, L2, L3 Aluminum Casing System Amperage Neutral Iso Ground GM No GM100N No GM100NG Yes GM No B. Environmental Indoor, Low Impedance System Ambient Operating Temperature: 40C / 104F 60C / 140F (0.8 Amp Rating Multiplier) Page

78 SECTION TRACK BUSWAY SYSTEM GM100G, GM100NG, GM100N, GM SUBMITTALS A. Submittals shall be in accordance with specified procedures. Submit shop drawing and product data for record purposes prior to shipment. B. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. C. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. D. Indicate special receiving and handling procedures. E. Provide electrical characteristics and connection requirements for the system and accessories WARRANTY A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment COMPONENTS A. Frame and Enclosure: 1. Extruded Aluminum housing designed to act as a 100% ground. Housings to be 3 or 6 Metres standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. This opening shall pass UL s hypothetical finger probe test. 2. All conductors shall be made of copper and sized to handle 100% of it s rating continuously with ambient temperatures below 40C / 104F. The conductors shall be electrically isolated from the housing. B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings INSTALLATION A. Track Busway Sections The runs will consist of lengths as shown on the drawings. B. Hanging of the Track Busway Using supplied Rod Mount Hangers the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3 m on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u-shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together. D. End of Runs End caps will be provided to install at the ends of each run. E. Closure Strip The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation; 168 Georgetown Rd; Canonsburg, PA 15317; USA ; fax Page

79 SECTION TRACK BUSWAY SYSTEM GM250T5, GM250T5G, GM250T5N, GM250T5NG 1.01 SUMMARY A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway. Voltage: Frequency: Ampacity: Neutral Ampacity: Conductors: Earth: System Designation: 415 V AC/DC 50/60 Hz 250A 250 or 500A 3 Phase conductors, 1 Neutral Conductor Solid Copper, Tin Plated Aluminum Casing 1.02 STANDARDS AND CERTIFICATION A. The Track Busway shall be designed and manufactured to the following standards: 1. Underwriters Laboratories Standard, UL 857 The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelfth edition of UL 857, and the second edition of NMX-J ANCE. 2. Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC : Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC : 2000.Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 4. ETL Certified (US/Canada) to UL National Electric Code (NEC) Article 368 Busways 6. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 7. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC) SYSTEM DESCRIPTION A. Electrical Requirements STARLINE Track Busway - Manufactured by: Universal Electric Corp. 168 Georgetown Rd. Canonsburg, PA (724) System Amperage Neutral Iso Ground GM250T No GM250T Yes G GM250T5N No GM250T5N Yes B. Environmental Indoor, Low Impedance System Ambient Operating Temperature: 40 C / 104 F 60 C / 140 F (0.8 Amp Rating Multiplier) 1.04 SUBMITTALS A. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. B. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. C. Indicate special receiving and handling procedures. D. Provide electrical characteristics and connection requirements for the system and accessories WARRANTY A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment. Page

80 SECTION TRACK BUSWAY SYSTEM GM250T5, GM250T5N, GM250T5G, GM250T5NG 1.06 COMPONENTS A. Frame and Enclosure 1. Extruded Aluminum housing designed to act as a 100% ground. Housings to be 3 or 4.5 M standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. This opening shall pass UL s hypothetical finger probe test. 2. All conductors shall be made of copper and sized to handle 100% of its rating continuously with ambient temperatures below 40 C / 104 F. The conductors shall be electrically isolated from the housing. E. Closure Strip The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation 168 Georgetown Rd Canonsburg, PA (800) ; (724) ; fax (724) No known equal. END OF SECTION B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings INSTALLATION A. Track Busway Sections The runs will consist of lengths as shown on the drawings. B. Hanging of the Track Busway Using supplied Rod Mount Hangers the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3M on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u- shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together. D. End of Runs End caps will be provided to install at the ends of each run. Page

81 SECTION TRACK BUSWAY SYSTEM GM400, GM400N, GM400G, GM400NG 1.01 SUMMARY A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway STANDARDS AND CERTIFICATION A. The Track Busway shall be designed and manufactured to the following standards: 1. Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 2. Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC : Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC : Underwriters Laboratories Standard, UL 857 The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelvth edition of UL 857, and the second edition of NMX-J ANCE. 5. ETL Classified (US/Canada) to UL National Electric Code (NEC) Article 368 Busways 7. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 8. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC) SYSTEM DESCRIPTION A. Electrical Requirements STARLINE Track Busway Manufactured by: Universal Electric Corp. 168 Georgetown Rd. Canonsburg, PA (724) Voltage: Frequency: Ampacity: Neutral Ampacity: Conductors: Earth: System Designation: 415 V AC/DC 50 Hz 400A 400A or 800A Qty 4 (Phases L1, L2, L3 and Neutral) Aluminum Casing System Amperage Neutral Iso Ground GM No GM400N No GM400G Yes GM400NG Yes B. Environmental Indoor, Low Impedance System Ambient Operating Temperature: 40 C / 104 F 60 C / 140 F (0.8 Amp Rating Multiplier) 1.04 SUBMITTALS A. Submittals shall be in accordance with specified procedures. Submit shop drawing and product data for record purposes prior to shipment. B. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. C. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. D. Indicate special receiving and handling procedures. E. Provide electrical characteristics and connection requirements for the system and accessories WARRANTY A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment. Page

82 SECTION TRACK BUSWAY SYSTEM GM400, GM400N, GM400G, GM400NG 1.06 COMPONENTS A. Frame and Enclosure 1. Extruded Aluminum housing designed to act as a 100% ground. Housings to be 1.5 or 3m standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. This opening shall pass UL s hypothetical finger probe test. 2. All conductors shall be made of copper and sized to handle 100% of it s rating continuously with ambient temperatures below 40 C / 104 F. The conductors shall be electrically isolated from the housing. B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings. D. End of Runs End caps will be provided to install at the ends of each run. E. Closure Strip The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation 168 Georgetown Rd Canonsburg, PA (800) ; (724) ; fax (724) No known equal. END OF SECTION 1.07 INSTALLATION A. Track Busway Sections The runs will consist of lengths as shown on the drawings. B. Hanging of the Track Busway Using supplied Rod Mount Hangers the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3m on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u- shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together. Page

83 SECTION TRACK BUSWAY SYSTEM GM800T5CG, GM800T5GCC, GM800T5CA, GM800T5GCA 1.01 SUMMARY A. This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred to as (Track Busway). The system shall be designed primarily for overhead distribution of electrical power. Supporting designated work areas and equipment. Once installed the Busway will provide a simple, versatile, fast and economic means of distributing power. Loads fed from a variety of plug-in units can be easily added or removed without shutting power down to the busway. Voltage: Frequency: Ampacity: Neutral Ampacity: Conductors: Copper: Composite: Earth: System Designation: 415 V AC/DC 50/60 Hz 800A 800A 3 Phase conductors, 1 Neutral Conductor Solid Copper, Nickel Plated Continuous nickel plated Copper contact surface within nickel plated aluminum busbar Aluminum Casing 1.02 STANDARDS AND CERTIFICATION A. The Track Busway shall be designed and manufactured to the following standards: 1. Underwriters Laboratories Standard, UL 857 The common UL, CSA, and ANCE Standard for Busways that is derived from the fifth edition of CSA Standard C22.2 No. 27, the twelfth edition of UL 857, and the second edition of NMX-J ANCE. 2. Low Voltage Switchgear and Controlgear Assemblies, Part 1: Type Tested and partially type tested Assemblies, IEC : Low Voltage Switchgear and Controlgear Assemblies, Part 2: Particular Requirements for Busbar Trunking systems (Busways), IEC : 2000.Low Voltage Directive (73/23/EEC) including Amendment (93/68/EEC). 4. ETL Certified (US/Canada) to UL National Electric Code (NEC) Article 368 Busways 6. NEMA AB1, Molded Case Circuit Breakers and Molded Case Switches 7. NEMA KS-1, Enclosed and Miscellaneous Distribution Equipment Switches (600VAC). 8. NFPA 70 National Fire Protection Agency 1.03 SYSTEM DESCRIPTION A. Electrical Requirements STARLINE Track Busway Manufactured by: Universal Electric Corp. 168 Georgetown Rd. Canonsburg, PA (724) System Amperage Neutral Iso Ground GM800T5C No C GM800T5G Yes CC GM800T5CA No GM800T5G CA Yes B. Environmental Indoor, Low Impedance System Ambient Operating Temperature: 40 C / 104 F 60 C / 140 F (0.8 Amp Rating Multiplier) 1.04 SUBMITTALS A. Submittals shall be in accordance with specified procedures. Submit shop drawing and product data for record purposes prior to shipment. B. Indicate construction details, including dimensions, weights, clearances, major component layout, power details. Include circuit breaker, fused plug-in, and cable schedule (if applicable), including cable lengths and plug-in schedules. C. Include connection diagram for external wiring, and details of conduit and wiring connections and terminations. D. Indicate special receiving and handling procedures. E. Provide electrical characteristics and connection requirements for the system and accessories WARRANTY A. The Track Busway manufacturer shall guarantee the entire system against defective material and workmanship for a period of one (1) year from date of shipment. Page

84 SECTION TRACK BUSWAY SYSTEM GM800T5CG, GM800T5GCC, GM800T5CA, GM800T5GCA 1.06 COMPONENTS A. Frame and Enclosure 1. Extruded Aluminum housing certified to serve as a 100% ground. Housings to be 1.5 3m standard length. This housing should be properly extruded with slots to receive rod mount hangers to hang from a ceiling. This housing should be open on the bottom to accept plug-in units anywhere along its length. 2. All conductors shall be made of copper or composite copper/aluminum and sized to handle 100% of it s rating continuously with ambient temperatures below 40 C / 104 F. The conductors shall be electrically isolated from the housing. B. Plug-in Units 1. Plug-in units shall be polarized to avoid incorrect installation. 2. Plug-in units shall use [{circuit breakers} {fuses}] for branch circuit protection. 3. Plug-in units shall have locking clips or bolt-on tabs to secure units to the busway. 4. Plug-in units that include drop cords shall be manufactured with cord grips and receptacles as specified in the drawings. D. End of Runs End caps will be provided to install at the ends of each run. E. Closure Strip The closure strip can be cut and fitted to cover the bottom opening of the Track Busway housing to prevent dust and debris from gathering in the Track Busway (if applicable). Supply as manufactured by Universal Electric Corporation 168 Georgetown Rd Canonsburg, PA (800) ; (724) ; fax (724) No known equal. END OF SECTION 1.07 INSTALLATION A. Track Busway Sections The runs will consist of lengths as shown on the drawings. B. Hanging of the Track Busway Using supplied Rod Mount Hangers the busway will be hung from the ceiling using all thread. The installing contractor shall be responsible for the connections on the ceiling end. The supplied Rod Mount Hangers will connect the track busway to the all thread. The maximum spacing is 3m on center for the hangers. The height of the track busway shall be coordinated with the Architect. C. Connecting Sections of Track Busway At a junction of Track Busway sections, the installer will install the top housing coupler; the bus connector is inserted, centered and seated in the slot of the Busway. The installation tool is inserted into jointed intersection and rotated 90 deg. Forcing stabs into u- shaped female conductors. Housing coupler is positioned over the bottom joint and tightened. A manufacturer supplied tool will assist in joining sections together. Page

85 Universal Electric Corporation (UEC), the manufacturer of STARLINE, has been a leader in power distribution since The company s founders led the way for many new technologies in the power distribution equipment industry. Today, this family tradition of innovation continues to pave the way for safer, more innovative and more reliable electrical power distribution systems. Visit for your Flexible Power Solutions. For installation details, Electrical Estimating cost comparisons, and actual case histories of projects where savings with STARLINE have been documented, contact UEC s Customer Service Department at the locations listed below. info@uecorp.com UK & Northern Europe City Point, 1 Ropemaker Street London EC2Y 9HT Asia Pacific Region Office Level 8 Samsung Hub 3 Church Street Singapore S.W Asia Region Office Ground Floor, E-1 Block, Beech Building Manyata Embassy Business Park Outer Ring Road Bangalore, India United States 168 Georgetown Road Canonsburg, PA Most STARLINE systems and most standard components are UL, CE or ETL listed. IEC Edition Low-voltage switchgear and controlgear assemblies Part 6: Busbar trunking systems (busways) F /13 F /2014

Product Selection Guide: T5 Series- 250, 400 & 800 Amps

Product Selection Guide: T5 Series- 250, 400 & 800 Amps Selection Guide: T5 Series- 250, 400 & 800 Amps T5 Series INTRODUCTION & SPECS Specs This specification covers the electrical characteristics and general requirements for a track busway system, hereafter

More information

Product Selection Guide

Product Selection Guide Selection Guide Selection Guide TABLE OF CONTENTS T1 Series: 40, 50 & 60 Amps...1.1-1.29 T2 Series: 60, 100 Amps...2.1-2.44 T3 Series: 100 & 225 Amps...3.1-3.37 T5 Series: 250, 400 & 800 Amps...4.1-4.51

More information

COMPACT BUSWAY 40 & 60 AMP HOUSING

COMPACT BUSWAY 40 & 60 AMP HOUSING 40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum

More information

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax:

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax: 168 Georgetown Road Canonsburg, PA 15317 USA Phone: 724-597-7800 Toll Free: 800-245-6378 Fax: 724-916-2221 www.uecorp.com info@uecorp.com A DIVISION OF Introduction Plug-In Accessories Application Briefs

More information

Product Selection Guide: T3 Series- 100 & 225 Amps

Product Selection Guide: T3 Series- 100 & 225 Amps Selection Guide: T3 Series- 100 & 225 Amps T3 Series INTRODUCTION & SPECS Specs This specification covers the electrical characteristics and general requirements for a track busway system, hereafter referred

More information

PDI PowerWave 2 Bus System

PDI PowerWave 2 Bus System 1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening, low voltage, vertical or horizontal power busway distribution system. System

More information

Plug-In Raceway - Power

Plug-In Raceway - Power Plug-In Raceway - Power End Caps Vertical Elbow Page PR.1 Power Feeds Wall Clip Horizontal Elbows Plug-In Units Joiner Kit Plug-In Raceway - Power HOUSING SECTION Each Plug-In Raceway housing section consists

More information

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION PowerWave Bus System tm For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION PDI PowerWave Bus System tm : designed specifically for the Critical Power Market The

More information

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems Conduit and Wire Must be scrapped whenever reconfiguration of the electrical layout is needed. Many runs may be needed for applications with a high volume or high density of electrical loads. It is labor

More information

Put the Power in Your Hands

Put the Power in Your Hands Put the Power in Your Hands StarlineTrack Busway... STARLINE Track Busway is quickly becoming the industry standard for power distribution systems. Introduced in 1988, this innovative system is a modular,

More information

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E 100-Ampere Busway Technical Data TD01701002E Effective November 2005 New Information Elbow, Busway and Cable Tap Box Contents General Information.............................. 2 Connections...............................

More information

PowerWave 2 TM Bus System

PowerWave 2 TM Bus System PowerWave 2 TM Bus System 250A 800A Installation and Operation Ctrl Nr: PM375106 Revision: 001 PowerWave 2 Bus System Installation and Operation Thank you for your recent purchase of a PowerWave 2 Bus

More information

Flexible, Customizable Power Solutions for Mission Critical Success

Flexible, Customizable Power Solutions for Mission Critical Success Flexible, Customizable Power Solutions for Mission Critical Success The most critical decision, for mission critical facilities. By their very nature, mission critical and data center facilities are extremely

More information

Pow-R-Flex low ampere busway

Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway Commercial Industrial Telecommunications Data centers Research Light manufacturing Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway Pow-R-Flex low ampere busway provides

More information

Flexible, Customizable Power Solutions for Mission Critical Success

Flexible, Customizable Power Solutions for Mission Critical Success Flexible, Customizable Power Solutions for Mission Critical Success The most critical decision, for mission critical facilities. By their very nature, mission critical and data center facilities are extremely

More information

BUSWAY Low Voltage (Pow-R-Flex)

BUSWAY Low Voltage (Pow-R-Flex) BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and

More information

SURFACE TRACK (120/250V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS SURFACE TRACK (120/250V) SPECIFICATIONS GENERAL Lighting Track shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized and removed

More information

INTELLIGENT MEDIUM POWERBAR

INTELLIGENT MEDIUM POWERBAR INTELLIGENT MEDIUM POWERBAR POWERBAR INTRODUCTION TECHNICAL FEATURES Intelligent Medium Powerbar is a patented range of busbar trunking that is utilized within Data Centers and various industrial applications

More information

INTELLIGENT MEDIUM POWERBAR impb

INTELLIGENT MEDIUM POWERBAR impb INTELLIGENT MEDIUM POWERBAR impb INTELLIGENT MEDIUM POWERBAR impb E+I Engineering s Intelligent Medium Powerbar (impb) is a 600 Volt encased track busduct. The range is available in two bar configurations

More information

Underfloor to desk 231

Underfloor to desk 231 Technical information Underfloor to desk 231 Series 507 Powertrack Series 507 Powertrack is an underfloor busbar system rated at 63Amp maximum. It is available in Standard or CE (Clean Earth) versions.

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

POWERBUS 225 Busway and Plug-In Units

POWERBUS 225 Busway and Plug-In Units Busway and Plug-In Units Class 5600 CONTENTS Schneider Electric Brands Description Page Product Descriptions.................................................. 3 POWERBUS 225 Busway System.....................................

More information

Product Selection Guide

Product Selection Guide Selection Guide INTRODUCTION At A Glance Designed to meet the ever-changing power distribution and datacom needs of research, pharmaceutical, university, hospital, and data labs. Add or relocate plug-in

More information

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Reduced-profile, single-circuit trac sections for surface or pendant mounting. Compatible with a full range of feed, connector

More information

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single

More information

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System 25-32 A Lighting Busbar System 4-63 A Plug-in Busbar Distribution System / CONTENTS E-LINE / General 2-3 System 4 Technical Characteristics 5 Standard Busbars 6 Standard Elements 7 Tap Off Plugs 8 Standard

More information

INTEGRID TRACK (120V) SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to

More information

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: This Product is Listed by UNDERWRITERS LABORATORIES INC. and Bears the Mark: This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark: SLATER SCD Installation Instructions For Self-Contained

More information

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, two-circuit trac sections for surface or pendant mounting. Provides two separate 20-amp circuits from a single

More information

Busway Construction. Bus Bars

Busway Construction. Bus Bars Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars

More information

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and

More information

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design Selection and Application Guide busway system XJ-L Cost-effective Power Distribution Compact Design Specifications New for 2007..400A XJ-L Busway XJ-L Busway is available up to 400A. First introduced in

More information

Battery Cables. Wire & Cable

Battery Cables. Wire & Cable Battery Cables Why Use Larger Cable? Low-voltage power systems with inverters can have very high current through the cables that connect the inverter to the batteries. Large AC loads like microwave ovens,

More information

Flexible, Customizable Power Solutions for Mission Critical Success

Flexible, Customizable Power Solutions for Mission Critical Success Flexible, Customizable Power Solutions for Mission Critical Success The most critical decision, for mission critical facilities. By their very nature, mission critical and data center facilities are extremely

More information

HIGH POWERBAR COPPER UL857

HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 HIGH POWERBAR COPPER UL857 E+I Engineering s High Powerbar (HPB) UL857 range is a 600 Volt totally encased, non-ventilated, low impedance busduct. The range is available from

More information

Sunwize Power Ready Express Quick Start

Sunwize Power Ready Express Quick Start Document # 310002 Sunwize Power Ready Express Quick Start The purpose of this guide is to assist you in setting up your system quickly and efficiently. Important! Prior to field installation Determine

More information

SURFACE CONTROLTrack SPECIFICATIONS

SURFACE CONTROLTrack SPECIFICATIONS CONTROLTrack SURFACE CONTROLTrack SPECIFICATIONS GENERAL CONTROLTrack shall allow fixtures to be located anywhere along the track length. Fixtures shall be easily focused, switched, dimmed, accessorized

More information

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS.

CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS. CABLE MANAGEMENT SOLUTIONS CATALOGUE2003/04 A COMPLETE CABLE MANAGEMENT SOLUTION FOR COMMERCIAL AND INDUSTRIAL APPLICATIONS www.legrand.co.uk POWER TRACK THE QUICK-FIT VERSATILE SOLUTION Arena-Walsall

More information

LSI 20 Series 30A, 120V Surface Busway Components 1

LSI 20 Series 30A, 120V Surface Busway Components 1 LSI Busway System LSI 20 Series 30A, 120V Surface Busway Components 1 IBEW union made at LSI plant in USA Specification grade heavy duty.075 (1.8mm) extruded aluminum busway 8 foot (2.4m) and 12 foot (3.7m)

More information

RECESSED TRACK (120V) SPECIFICATIONS

RECESSED TRACK (120V) SPECIFICATIONS RECESSED TRACK (120V) SPECIFICATIONS GENERAL Recessed track shall be approved by the NEC for flush-mounting into ceiling or any flat surface. Recessed Track shall allow fixtures to be easily focused, switched,

More information

Congratulations on purchasing the epump solar pumping solution.

Congratulations on purchasing the epump solar pumping solution. Congratulations on purchasing the epump solar pumping solution. Please follow the easy step by step assembly instructions below. We also have an assembly video which can be viewed via our website Assembly

More information

Snake Bus Power Distribution

Snake Bus Power Distribution Snake Bus Power Distribution ELECTRICAL CHARACTERISTICS Rated Current 50 Amps Rated Voltage 208Y/120 or 480Y/277 Volts Frequency 50/60 Hz Conditional Short Circuit Rating (Protection device) 16 KA Conductor

More information

NT-300 Series Single Circuit Track System & Accessories

NT-300 Series Single Circuit Track System & Accessories NT-300 Series Single Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral copper conductors.

More information

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions .1 Features, Benefits and Functions Pow-R-Way III Offers a Full Line of to Meet the Needs of the Global Marketplace Eaton Corporation has combined the requirements of NEMA, UL, CSA and IEC into one design

More information

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series Project: Fixture Type: Location: Contact/Phone: PRODUCT DESCRIPTION DIMENSIONS Low-Profile, single-circuit trac sections for surface or pendant mounting. I-beam cross section provides added strength and

More information

Low voltage busway Pow-R-Flex low ampere busway

Low voltage busway Pow-R-Flex low ampere busway Contents Description Page Description Page General information........................ 2 General description........................ 2 Standards................................ 2 Conductor details..........................

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

Zucchini Low-Medium Power

Zucchini Low-Medium Power Zucchini Low-Medium Power High Power CATALOGUE 2010 CATALOGUE 2010-2011 ZHP08C/GB Coordination table with Legrand DPX MCCBs SL, MS, SB, MR Switch-Busbar coordination table. Contingent short circuit ka

More information

Accessories. Accessories. Meter Mounting Equipment

Accessories. Accessories. Meter Mounting Equipment Covers & Sealing Rings..................................................................... 119 AW & H-Base Hubs.......................................................................... 119 Flush Trim

More information

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications New Product Bulletin NP 307 PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications NFPA-79-2002 Standard Compliance Eliminates the need for Conduit or

More information

Power Distribution Blocks

Power Distribution Blocks ower istribution Blocks A OWERFUL WAY TO MANAGE YOUR OWER ISTRIBUTION CHALLENGES Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or the compatibility

More information

Steel Conduits Conduit Fittings Flexible Conduits

Steel Conduits Conduit Fittings Flexible Conduits Conduits Conduit Fittings Flexible Conduits CONTENT 1. INTRODUCTION VOLTECX products introduction and selecting VOLTECX 2. STEEL CONDUITS VOLTECX BS4568: Part 1: 1970 (Class 4) Conduit IEC 61386-21:2004;

More information

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems Juno Trac-Master Trac Lighting Systems Comprehensive line and low voltage track systems Juno Trac-Master System Safe and simple installation is what you can expect from Juno one-circuit and two-circuit

More information

A powerful way to manage your power distribution challenges. I Power Distribution Blocks

A powerful way to manage your power distribution challenges. I Power Distribution Blocks I Power Distribution Blocks A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

General Specifications for Lighthouse Power Pedestal

General Specifications for Lighthouse Power Pedestal Dimensions Height: 44.00 11 (1117.60 mm) Width: 13.67" (347.22 mm) Depth: 13.75" (349.25 mm) Lighthou98 Base Diagram ---13,75 1 --- Approximate Weight: 30 lbs. (13.6 kg) Multiply base dimensions by 25.4

More information

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs... Power Distribution Blocks I A powerful way to manage your power distribution challenges. Your problem: You re facing the enormously complex wiring requirements of an automated manufacturing facility. Or

More information

MR - MEDIUM RATING A

MR - MEDIUM RATING A 88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

Open-Style Power Distribution Blocks

Open-Style Power Distribution Blocks MPDB Series Open-Style Power Distribution Blocks Power distribution The Next Generation Power Distribution Block (PDB) Ratings: Volts: 000VAC/DC Amps: 65 to 2260A based on NEC table 30.5(B)(6) 75ºC ampacities

More information

KAP A Plug-in Busbar Distribution System IEC ME 04

KAP A Plug-in Busbar Distribution System IEC ME 04 EAE Elektrik A.Ş. Akcaburgaz Mahallesi, 119. Sokak, No:1 341 Esenyurt-Istanbul-TURKEY Tel: +9 (212) 866 2 Fax: +9 (212) 886 24 2 www.eae.com.tr 2-32 A Lighting Busbar System Y A N D EN V E IT AL s ISO

More information

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500 Installation Instructions CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns Catalog Number 2500 Topic Page Important User Information 2 Location Planning 3 Environment 3 Removal

More information

Electrical Wiring Practices

Electrical Wiring Practices Chapter 2 Electrical Wiring Practices and Diagrams MElec-Ch2-1 Overview Safety Standards Wiring Considerations Wire Terminations Coaxial Cable Wiring Installations Wiring Diagrams MElec-Ch2-2 Safety Lethal

More information

INTERWORKS EQ. Table of Contents. Panel System. Interworks EQ Kimball Legacy. Price List Effective Dates: Pricing Revision

INTERWORKS EQ. Table of Contents. Panel System. Interworks EQ Kimball Legacy. Price List Effective Dates: Pricing Revision INTERWORKS EQ Table of Contents Price List Effective Dates: 07.02.18 Revision 06.15.18 See page Statement of Line page 14.2 Panels, Connectors, Trim page 14.2 Power and Data page 14.3 Overview page 14.4

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

NFPA 70E 68! & CSA Z462

NFPA 70E 68! & CSA Z462 DB Switch-Rated plug and receptacle Main Advantages u Switch & Hp rated u 100 ka short circuit rated* u IP67 environmental ratings u Up to 4 auxiliary contacts u Durable metal construction * See note under

More information

Charging Battery Based Power Supply Systems Remote Terminal Units (RTU) Power Conditioning for Controls & Instrumentation Switchgear

Charging Battery Based Power Supply Systems Remote Terminal Units (RTU) Power Conditioning for Controls & Instrumentation Switchgear Features: TECHNICAL DATASHEET #TDAX080000 48V-24V DC/DC Converter 240 Watts (24VDC) Isolated, Rugged P/N: AX080000K 48V-24V DC/DC Converter Input operating voltage range from 35 to 75VDC Conditioned output

More information

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B

Electrical Applications. Metal Framing & Cable Tray Superstrut Metal Framing System. Column A. Design Data: Materials: Column B Electrical Raceway Series 800 Surface Raceway and Lighting Systems Superstrut channel together with snap-in closure strip is listed by Underwriters Laboratories as a surface metal raceway. Other accessories

More information

MNBRATKIT MidNite Brat Solar Charging Kit

MNBRATKIT MidNite Brat Solar Charging Kit 1 pc MNBRAT 20/30-amp PWM Charge Controller 1 pc MNBIGBABY Breaker Box 3 pcs 1-10A 1-20A 1-30A MNEPV- PV, Battery and Load Breakers 2 pcs 2 pcs 9-161-1 Strain Relief 9-162-1 Lock Nut 2-4 Hole Strain Reliefs

More information

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED 2 CIRCUIT TRACK SURFACE TRACK COLOR INSTALLATION PROFILE WHITE POWDER COAT SILVER ANODIZED PLASTER FLANGE RECESSED VISIBLE FLANGE RECESSED BLACK ANODIZED Page 1/9 SURFACE TRACK SYSTEM : compose your system

More information

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL SAFETY INSTRUCTION Read all of these instructions before installing the track system. Turn off power at main switch before installing or modifying

More information

EASY CONNECT CRANE KIT Festoon Conductor Systems

EASY CONNECT CRANE KIT Festoon Conductor Systems ASSEMBLY INSTRUCTION MANUAL EASY CONNECT CRANE KIT Festoon Conductor Systems October, 2005 Copyright 2005, Yale Lift-Tech, division of Columbus McKinnon Corporation Part No. 117463-05 Mounting Instructions

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals Lighthouse-SS Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 9.565" (242.95 mm) Depth: 9.875" (250.83 mm) Lighthouse-SS Base Diagram Ø0.50" MOUNTING HOLE (TYP.) 9.5625" 8.0625" 7.3125" C:\Documents

More information

2-row and All-row systems included.

2-row and All-row systems included. Ag Leader Technology Cotton Picker Installation Installation Instructions for John Deere cotton picker models: 2-row and All-row systems included. IMPORTANT: Ensure the model numbers shown above correspond

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

RAPIER DSB Disconnectors

RAPIER DSB Disconnectors RAPIER DSB Disconnectors and Copper and Aluminium Substation Connectors ENGINEERING BRILLIANT SOLUTIONS Rapier DSB disconnector The Rapier Double Side Break 'DSB' range provides a powerful and cost effective

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals Hatteras Light Power Pedestal Dimensions Height: 31.00" (787.40 mm) Width: (190.50 mm) Depth: (190.50 mm) Hatteras Light Base Diagram Approximate Weight: 14 lbs. (6.4 kg) 1.73" UL FILE # E133781 Ø0.41

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

Recreational Vehicle Park Electrical Products & Accessories

Recreational Vehicle Park Electrical Products & Accessories Recreational Vehicle Park Electrical Products & Accessories 2 MILBANK OVERVIEW Milbank Overview Energy At Work since 1927 Milbank designs and manufactures electrical solutions that move and manage power

More information

Open-Style Power Distribution Blocks

Open-Style Power Distribution Blocks I MPDB Series Open-Style Power Distribution Blocks The Next Generation Power Distribution Block (PDB) Ratings: Volts: 1000Vac/DC Amps: 65 to 2260A based on NEC table 310.15(B)(16) 75ºC ampacities Mersen

More information

circuit protection & wiring accessories

circuit protection & wiring accessories circuit protection & wiring accessories J J1 circuit breakers Circuit breakers and fuses are a cost-effective solution to protecting wiring, equipment and subsystems. While fuses are a one-time, disposable

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

Series 3 & 4 Stainless Steel - Accessories

Series 3 & 4 Stainless Steel - Accessories - Accessories Splice Plates Standard 8-hole pattern for all steel splice plates. One pair including hardware provided with straight section. (Expansion splice quantity subtracted) Boxed in pairs with hardware.

More information

Hot and Cold Plumbing Manifold Systems

Hot and Cold Plumbing Manifold Systems Hot and Cold Plumbing Manifold Systems Hot and Cold Manifold Overview By using an Emmeti manifold system in a point to point plumbing configuration you can greatly reduce the number of joints in your system,

More information

WavePro LT Busway Cost effective solution for electrical distribution

WavePro LT Busway Cost effective solution for electrical distribution Busway Cost effective solution for electrical distribution 1/ Busway 20 year life Mylar wrap insulation Up to 5000A for both Feeder and Plug-In IP 40/42/55/65 protections 50% AL housing ground with internal

More information

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions GS-IOB-230VAC Input/Output/Bypass Assembly Installation Instructions Purpose This document provides information on how to install the Input/Output/Bypass Assembly needed for a single-phase configuration

More information

Series 2, 3, 4, & 5 Aluminum - Accessories

Series 2, 3, 4, & 5 Aluminum - Accessories The following is a list of accessories and fittings that can be provided with S8 tray. For more information on these items, contact our Engineering Department. Fittings Horizontal Bends 30 Bends with 24,

More information

VOLKSWAGEN AMAROK 1 & 3 PIECE HARD TONNEAU REMOTE LOCKING KIT INSTALLATION INSTRUCTIONS

VOLKSWAGEN AMAROK 1 & 3 PIECE HARD TONNEAU REMOTE LOCKING KIT INSTALLATION INSTRUCTIONS VOLKSWAGEN AMAROK & PIECE HARD REMOTE LOCKING KIT INSTALLATION INSTRUCTIONS Care Instructions: Clean Tonneau Cover with a mild detergent and water solution. Do not use abrasive cleaners or solvents. Place

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

Flame-retardant PVC offers the protection you need.

Flame-retardant PVC offers the protection you need. Solid wall wiring duct Flame-retardant PVC offers the protection you need. Solid wall duct PVC Engineered to restrict wire access Constructed of flame-retardant PVC Improved flush sidewall and cover style

More information

XL Distribution enclosures WORKSHOP SPECIFICATIONS

XL Distribution enclosures WORKSHOP SPECIFICATIONS 800 Distribution enclosures WORKSHOP SPECIFICATIONS With its extensive ranges, the Legrand offer meets your quality standards and provides real freedom and simplicity of installation together with acknowledged

More information

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount 1 2 Writing for light point/ fan point/ exhaust fan point /call bell point with 1.5 sq.mm FR PVC insulated

More information

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) Supersedes April 2014 UL Class CC, CF (CUBEFuse ), Midget and IEC 10x38mm DIN-Rail Contents Description Page Description Page 1-, 2- and 3-Pole Class CC, Midget, 10x38mm Description & Specifications....

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals

Terminal Blocks Product Catalog Terminal Block Supplement. Introduction. 8WH6 ipo Plug-In Terminals. 8WH6 ipo Installation Terminals Terminal Blocks 2013 Product Catalog Terminal Block Supplement Introduction 8WH6 ipo Plug-In Terminals 8WH6 ipo Installation Terminals 8WH2 Spring-Loaded Terminals 1 2 3 4 8WH 8WH5 Combination Plug-In

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information