Architectural Specifications. Division 14 Elevators Dumbwaiters

Size: px
Start display at page:

Download "Architectural Specifications. Division 14 Elevators Dumbwaiters"

Transcription

1 rchitectural Specifications ivision 14 Elevators umbwaiters

2 This page intentionally left blank

3 Waupaca Elevator Residential Elevators Residential and ommercial umbwaiters dvantages National Network of ealers In usiness For More Than 50 years Family Owned and Operated ustomer Service Orientated Index ompany Information Elevator Terminology Waupaca Elevator Warranty The products listed in the following sections are based upon our standard sizes. ustomization is available, contact us for additional information. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 1. 1

4 Waupaca Elevator ompany, Inc N. allard Road - ppleton, Wisconsin fax csr@waupacaelevator.com Website and ownloadable Product rochures Locate a ealer Near You Navigate to our website click on Locate ealer and complete the on-line questionnaire. Following submission of the questionnaire you will be given access to our on-line preferred dealer list. If you are still unsure of which dealer to choose, call us for assistance. History of the Waupaca Elevator ompany We opened our doors in 1957 in Waupaca, Wisconsin with a staff of 6 employees. fter only a couple of years the company redirected its manufacturing focus to dumbwaiters and later introduced residential elevators. emand grew, and in 1998 the company moved to a larger facility in ppleton, Wisconsin. fter only four years, the company s continued growth created the opportunity to move to its current location which has room for future expansion. Today, Waupaca Elevator employs over 70 employees who produce beautiful residential elevators and dumbwaiters. Product Introductions Year Product Name Function Weight apacities 1962 Paca-Waiter Screw rive umbwaiter 200 lbs., 300 lbs. & 500 lbs Mini-Waiter Screw riveumbwaiter 50 lbs. & 100 lbs Paca-Lift Screw rive Elevator 500 lbs ustom-lift Winding rum Elevator 500 lbs Paca-Waiter Winding rum umbwaiter 200 lbs., 300 lbs. & 500 lbs able-waiter umbwaiter 50 lbs. & 100 lbs Excelevator Hydraulic Elevator 750 lbs. & 950 lbs ustom-lift Winding rum Elevator 1,000 lbs Paca-Glide MRL Winding rum Elevator 1,000 lbs Paca-Lift Winding rum Elevator 1,000 lbs Paca-Ryde Hydraulic Elevator 1,000 lbs. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 1. 2

5 Waupaca Elevator Elevator Terminology utomatic Gate Operator n electro/mechanical device that opens and closes the car gate automatically. attery ackup n emergency power source that will allow you to lower the elevator to the next lower level in the event of a power failure. alling the Elevator or all utton Pressing the call button in the hallway will call the elevator to you, if the elevator is not in use and/or is located on a different level. ar The elevator car transports passengers from one floor to another..o.p. The ar Operating Panel (.O.P.) is the control panel inside the elevator that houses the floor buttons, the light switch, the alarm button, the emergency stop switch and optional key lock. ontroller The controller houses the electrical control circuits of the elevator. rive System The drive system is the power and strength behind lifting the elevator car and its passenger(s). Waupaca Elevator utilizes two types of drive systems, winding drum and roped hydraulic. umbwaiter Is a self contained car that is lowered and raised on a vertical path. Waupaca Elevator dumbwaiters can carry loads from 50 lbs. to 500 lbs. depending on the model chosen. Load examples may be fireplace wood, grocery bags, laundry and paperwork. Electromechanical Interlock Often referred to as EMI, is an electromechanical safety lock that prevents the hoistway door (hall door) from opening if the elevator is not at that landing. Gate The gate is a door that attaches to the outer edge of the elevator or dumbwaiter car. It prevents objects inside the car from coming into contact with objects outside of the car during travel. Gate styles include accordion and scissors for elevators and bi-part, slide-up and roll top gates for dumbwaiters. Hall Station The Hall Station refers to the panel located outside the elevator doorway in the hallway that houses the call button. Hoistway The hoistway is the enclosed space in which the elevator travels. Hoistway oor The door that allows entry or exit from the elevator car. It will be prevented from opening mechanically unless the elevator car is at that particular landing. Home Elevator - n elevator specifically designed to be installed in a single family residence. Hydraulic (Roped) This drive system utilizing a hydraulic jack and a wire rope to raise and lower the passenger car. The Waupaca elevator hydraulic elevator is known as the Excelevator. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 1. 3

6 Waupaca Elevator Elevator Terminology Jack - The piston utilizes hydraulic power to lift or lower the passenger car. Landing term used to describe each floor on which the elevator will open. Machine Room The machine room is a small adjacent room that houses the drive system and electrical controls. Machine Roomless - Waupaca Elevator s Paca-Glide is an example of a machine room-less elevator, since the drive system is located on top of the rail in the hoistway. The control box is located nearby but does not require a separate room. Muntz Muntz is the name given to the brass tone finish (without the tarnishing) on the hall stations and car operating panel. Oxide, ark or Light - dark coloring is brushed over the Muntz. - ark Oxide is almost black with a hint of the Muntz brass tone below. - Light Oxide is a blend of the dark coloring and the underlying brass toned Muntz. Pit The pit provides clearance for the support components that are below the floor of the elevator car allowing the elevator floor to level with the lowest landing floor. Rail The rail is the steel track that guides the elevator when it travels up and down the hoistway. epending on the model there may be one or two rails. Residential Elevator - same as Home Elevator. Service isconnect Located near the controller in the machine room, the service disconnect is the main power switch to the elevator. Sheave Elevator term for a pulley. Sling - The sling is a L-shaped steel support that holds the elevator car and is attached to the rail system, also referred to as the car frame. Weight apacity Is the total amount of weight that can be added to the elevator. For safety purposes, never exceed the elevator cars weight capacity. Winding rum Elevator This drive system utilizes wire ropes that wind onto a rotating drum. Waupaca Elevator s ustom-lift and Paca-Glide are winding drum elevators. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 1. 4

7 Waupaca Elevator Limited Warranty This product, the Serial Number of which is is subject to a Limited Warranty (as defined below) by Waupaca Elevator ompany, Inc. (WEO). It applies for the earlier of: 1. Two (2) years from the date of installation, up to a maximum of thirty (30) months from the date of shipment from the factory provided the warranty card has been filled out and returned; or 2. Twenty-Four (24) months from the date of shipment from the factory if the warranty card has not been filled out and returned. This Warranty is LIMITE. It covers any electrical or mechanical defects in material or workmanship, but does not cover any damage due to the following: (1) ccidents which are caused in whole or in part by someone other than WEO; (2) amage due to improper or neglected lubrication, or lack of other maintenance; (3) Improper power supply; (4) Improper installation; (5) Improper use or abuse; (6) Repairs or replacements done by someone other than an authorized representative of WEO; (7) lteration to the original design as manufactured by WEO. This Limited Warranty does not cover costs of repairs made or attempted outside of the factory unless the repairs are authorized in advance in writing by WEO. This Warranty is VOI if any alterations are made to the product outside of the factory except as provided in this Warranty. ny defective material or parts that are covered by this Warranty should be returned after first calling or writing WEO for a return shipping authorization and number, and mailing Postage Prepaid, to the following address: WUP Elevator ompany, Inc North allard Road ppleton, WI (800) The following written information must also be included with the returned parts: The authorized return material number, the product s serial number, the owner s name and address, and the dealer s name and address. Providing that an inspection by WEO shows the material or parts are defective as claimed, WEO will, at its option, either repair or replace (without charge) the material or parts. WEO is not responsible for any service or labor charges incurred in the removal and /or replacement of any parts covered by the Warranty. NEITHER THIS WRRNTY NOR NY OTHER WRRNTY, EXPRESS OR IMPLIE, INLUING NY IMPLIE WRRNTY OF MERHNTILITY OR OF FITNESS FOR PRTIULR PURPOSE, SHLL EXTEN THIS LIMITE WRRNTY. NO RESPONSIILITY IS SSUME FOR NY INIENTL OR ONSEQUENTIL MGES. SOME STTES O NOT LLOW LIMITTIONS ON HOW LONG N IMPLIE WRRNTY LSTS N SOME STTES O NOT LLOW THE EXLUSION OR LIMITTION OF INIENTL OR ONSEQUENTIL MGES, SO THE OVE LIMITTIONS OR EXLUSIONS MY NOT PPLY TO YOU. THIS WRRNTY GIVES YOU SPEIFI LEGL RIGHTS. YOU MY HVE OTHER RIGHTS, WHIH VRY, FROM STTE TO STTE. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 1. 5

8 This page intentionally left blank

9 Waupaca Elevator Residential Elevators Residential and ommercial umbwaiters dvantages WG and XF downloadable drawings Quick and easy PFs ontractor s Layout PFs Videos to share with clients ownloadable brochures and planning guides Index Marketing Materials Paca-Glide rawings Paca-Ryde rawings Paca-Lift rawings ustom-lift rawings Excelevator rawings able-waiter and Paca-Waiter rawings ontractor s Layouts contain hoistway construction dimensions only and they located on the with the regular drawings. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 1

10 General Information The marketing material found below are available for your review, print and/or . Specification sheets and Planning Guides are listed with each drive unit. Marketing Materials escription General Elevator rochure Residential umbwaiter rochure ommercial umbwaiter rochure Wall Street Journal rticle 4-05 Format PF PF PF PF Videos - escription Length Format Milwaukee Newscast minutes MPEG Videos - V escription Length Format Milwaukee Newscast minutes V Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 2

11 Paca-Glide ar onfiguration rawings on Series 015 These drawings are typical and intended for planning purposes only. Waupaca Elevator will supply job specific drawings once an order is placed. dditional layouts are available through your dealer. 48 x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF 54 x 40 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF Recommended size for wheelchair Recommended size for wheelchair and attendant Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 3

12 Paca-Glide Series x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF dditional rawings and Publications on onfiguration/subject rawing/part # rawing Type Paca Glide Specification Sheet- olored N/ PF Planning Guide -Paca-Glide PMQ0300- PF Minimum and Maximum imensions PF WG XF Notes and Specifications PF WG XF Rail Wall Reinforcement (equal to or less than 25 ) PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 4

13 Paca-Ryde ar onfiguration rawings on Series 016 These drawings are typical and intended for planning purposes only. Waupaca Elevator will supply job specific drawings once an order is placed. dditional layouts are available through your dealer. 48 x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF 54 x 40 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF Recommended size for wheelchair Recommended size for wheelchair and attendant Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 5

14 Paca-Ryde Series x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF dditional rawings and Publications on onfiguration/subject rawing/part # rawing Type Paca Glide Specification Sheet- olored N/ PF Planning Guide -Paca-Ryde PMQ0500 PF Minimum and Maximum imensions PF WG XF Notes and Specifications PF WG XF Rail Layout and Jack alculations PF WG XF Machine Room Layout PF WG XF Rail Wall Reinforcement (equal to or less than 25 ) PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 6

15 Paca-Lift ar onfiguration rawings on Series 018 These drawings are typical and intended for planning purposes only. Waupaca Elevator will supply job specific drawings once an order is placed. dditional layouts are available through your dealer. 48 x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF 54 x 40 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF Recommended size for wheelchair Recommended size for wheelchair and attendant Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 7

16 Paca-Lift Series x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF Sheave and Machine Room onfigurations onfiguration/subject rawing/part # rawing Type General Specifications PF WG XF Traveling Sheave Machine Room Layout PF WG XF Overhead Traveling Sheave Machine Room Layout PF WG XF djacent Right Machine Room Layout PF WG XF djacent Left Machine Room Layout PF WG XF Machine In Pit Traveling Sheaves Layout PF WG XF dditional rawings and Publications on onfiguration/subject rawing/part # rawing Type Paca Lift Specification Sheet- olored N/ PF Planning Guide -Paca-Lift PMQ0600 PF Minimum and Maximum imensions PF WG XF General Notes PF WG XF Rail Wall Reinforcement (equal to or less than 25 ) PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 8

17 ustom-lift ar onfiguration rawings on Series 010 & 210 These drawings are typical and intended for planning purposes only. Waupaca Elevator will supply job specific drawings once an order is placed. dditional layouts are available through your dealer. 48 x 36 Inside ar imensions onfiguration ode onfig. rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF Sheave and Machine Room onfigurations onfiguration/subject rawing/part # rawing Type General Specifications PF WG XF Traveling Sheave Machine Room Layout PF WG XF Overhead Traveling Sheave Machine Room Layout PF WG XF High Mount Sheave Machine Room Layout PF WG XF dditional rawings and Publications on onfiguration/subject rawing/part # rawing Type ustom-lift Specification Sheet- olored N/ PF Planning Guide -ustom-lift PMQ100 PF Minimum and Maximum imensions PF WG XF Sample Rail onstruction PF WG XF Notes & Specifications PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 9

18 This page intentionally left blank Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 10

19 Excelevator ar onfiguration rawings on 48 x 36 Inside ar imensions onfiguration ode rawing # rawing Type Series 014 These drawings are typical and intended for planning purposes only. Waupaca Elevator will supply job specific drawings once an order is placed. dditional layouts are available through your dealer. Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF 54 x 40 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Left Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF Recommended size for wheelchair Recommended size for wheelchair and attendant Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 11

20 Excelevator Series x 36 Inside ar imensions onfiguration ode onfiguration rawing # rawing Type Left Same Side Opening 1 R PF WG XF Left Same Side Opening 1 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Same Side Opening 2 R PF WG XF Right Front Opening PF WG XF Right Front Opening PF WG XF Opposite Openings 4 R R PF WG XF Opposite Openings 4 R R PF WG XF Right djacent 90 Openings 5 R PF WG XF Left djacent 90 Openings 6 R PF WG XF dditional rawings and Publications on onfiguration/subject rawing/part # rawing Type Excelevator Specification Sheet- olored N/ PF Planning Guide -Excelevator PMQ0200 PF Minimum and Maximum imensions PF WG XF Notes and Specifications PF WG XF Machine Room Layout PF WG XF Sheet #2 - Frame Field Installation PF WG XF Wall Reinforcement PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 12

21 umbwaiter ar onfiguration rawings on Series 007 & 011 These drawings are typical and intended for planning purposes only. Waupaca Elevator will supply job specific drawings once an order is placed. dditional layouts are available through your dealer. Wood ar with lassic Roll Top W = able-waiter PW = Paca-Waiter onfiguration ode onfig. Weight rawing # rawing Type Left Same Side Opening 1 W-50# PF WG XF Left Same Side Opening 1 W-100# PF WG XF Left Same Side Opening 1 PW-200# PF WG XF Right Same Side Opening 2 W-50# PF WG XF Right Same Side Opening 2 W-100# PF WG XF Right Same Side Opening 2 PW-200# PF WG XF Right Front Opening 3 W-50# PF WG XF Right Front Opening 3 W-100# PF WG XF Right Front Opening 3 PW-200# PF WG XF dditional rawings and Publications on onfiguration/subject rawing/part # rawing Type able-waiter Specification Sheet - olored N/ PF Paca-Waiter Specification Sheet - olored N/ PF Planning Guide -umbwaiter PMQ0400- PF Wall Reinforcement PF WG XF able-waiter Elevation Info WG XF able-waiter Elevation Info WG XF Paca- Waiter Elevation Info WG XF Paca-Waiter Elevation Info WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 13

22 umbwaiter Series 007 & 011 Steel ar with Gate W = able-waiter PW = Paca-Waiter onfiguration ode onfir. Weight rawing # rawing Type Left Same Side Opening 1 W-50# PF WG XF Left Same Side Opening 1 W-100# PF WG XF Left Same Side Opening 1 PW-200# PF WG XF Left Same Side Opening 1 PW-300# PF WG XF Left Same Side Opening 1 PW-500# PF WG XF Right Same Side Opening 2 W-50# PF WG XF Right Same Side Opening 2 W-100# PF WG XF Right Same Side Opening 2 PW-200# PF WG XF Right Same Side Opening 2 PW-300# PF WG XF Right Same Side Opening 2 PW-500# PF WG XF Right Front Opening 3 W-50# PF WG XF Right Front Opening 3 W-100# PF WG XF Right Front Opening 3 PW-200# PF WG XF Right Front Opening 3 PW-300# PF WG XF Right Front Opening 3 PW-500# PF WG XF Opposite Openings 4 W-50# PF WG XF Opposite Openings 4 W-100# PF WG XF Opposite Openings 4 PW-200# PF WG XF Opposite Openings 4 PW-300# PF WG XF Opposite Openings 4 PW-500# PF WG XF Right djacent 90 Openings 5 W-50# PF WG XF Right djacent 90 Openings 5 W-100# PF WG XF Right djacent 90 Openings 5 PW-200# PF WG XF Right djacent 90 Openings 5 PW-300# PF WG XF Right djacent 90 Openings 5 PW-500# PF WG XF Left djacent 90 Openings 6 W-50# PF WG XF Left djacent 90 Openings 6 W-100# PF WG XF Left djacent 90 Openings 6 PW-200# PF WG XF Left djacent 90 Openings 6 PW-300# PF WG XF Left djacent 90 Openings 6 PW-500# PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 14

23 umbwaiter Series 007 & 011 Steel ar with Gate and oor W = able-waiter PW = Paca-Waiter onfiguration ode onfig. Weight rawing # rawing Type Left Same Side Opening 1 W-50# PF WG XF Left Same Side Opening 1 W-100# PF WG XF Left Same Side Opening 1 PW-200# PF WG XF Left Same Side Opening 1 PW-300# PF WG XF Left Same Side Opening 1 PW-500# PF WG XF Right Same Side Opening 2 W-50# PF WG XF Right Same Side Opening 2 W-100# PF WG XF Right Same Side Opening 2 PW-200# PF WG XF Right Same Side Opening 2 PW-300# PF WG XF Right Same Side Opening 2 PW-500# PF WG XF Right Front Opening 3 W-50# PF WG XF Right Front Opening 3 W-100# PF WG XF Right Front Opening 3 PW-200# PF WG XF Right Front Opening 3 PW-300# PF WG XF Right Front Opening 3 PW-500# PF WG XF Opposite Openings 4 W-50# PF WG XF Opposite Openings 4 W-100# PF WG XF Opposite Openings 4 PW-200# PF WG XF Opposite Openings 4 PW-300# PF WG XF Opposite Openings 4 PW-500# PF WG XF Right djacent 90 Openings 5 PW-200# PF WG XF Right djacent 90 Openings 5 PW-300# PF WG XF Right djacent 90 Openings 5 PW-500# PF WG XF Left djacent 90 Openings 6 PW-200# PF WG XF Left djacent 90 Openings 6 PW-300# PF WG XF Left djacent 90 Openings 6 PW-500# PF WG XF Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 2. 15

24 This page intentionally left blank

25 Waupaca Elevator Electrical Information and odes Index Index Motor Size Voltage hart Logic Low Voltage Wiring hart National Electric ode Elevator ode uthority irectory SME Section 5.3 Private Residence Electric Elevators Section 7.0 umbwaiters Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 1

26 Waupaca Elevator Motor Wire Size Voltage hart Local supply is a factor that may require an increase of wire size. onsult your local codes and electrician. Motor H.P. Wire Size For 115 & 230 Volt Single Phase ircuits istance - Motor to Fuse or Meter ox - Feet 25 ft. 50 ft. 100 ft. 200 ft. 115V 230V 115V 230V 115V 230V 115V 230V 3/4 #12 #14 #12 #14 #10 #12 #6 #10 1 #8 #14 #6 #12 #4 #10 #4 #8 1-1/2 #8 #12 #6 #12 #4 #10 #0 #6 2 #12 #10 #8 #6 3 #10 #10 #8 #6 It is recommended that the hoistway and machine room be pre-wired during construction! Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 2

27 Waupaca Elevator Logic Low Voltage Wiring hart Wire OHMS / 100 FT. VOLTS LOSS / 100 FT. 5 MPS It must be remembered that if it takes 50 feet of wire to get to a switch, it also takes 50 feet to get back. If the voltage supplied to a device is less than 85% of the rated voltage of that device, the operation will be unreliable. For reference only, verify with multi-meter. It is recommended that the hoistway and machine room be pre-wired during construction! Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 3

28 Waupaca Elevator National Electrical ode The section in the Electrical ode book dealing specifically with elevators and other lifts is: RTILE ELEVTORS, UMWITERS, ESLTORS, MOVING WLKS, WHEELHIR LIFTS N STIRWY HIR LIFTS. For more information, a copy of the national Electrical ode or a copy of NFP s annotated National Electrical ode Handbook, contact: National Fire Prevention ssociation 1 atterymarch Park Quincy, M Fax Elevator ode uthority irectory The most current listing of Elevator ode uthorities can be found online at: Edward. onoghue sssocates, Inc ounty Rout 64 PO ox 201 Salem, NY Fax Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 4

29 Waupaca Elevator SME Section 5.3 Private Residence Elevators Synopsis Introduction This is a synopsis of the requirements most noteworthy to installers this is not a full list of all SME requirements. odes that do not apply to Waupaca designs are not included. Local codes and requirements may differ. Final interpretation and acceptance is subject to inspection by a code enforcing authority Private Residence Electric Elevators Hoistway Solid construction in conformance with local building codes Pit Guarded by the hoistway. Kept clean ar Top learance 6 inches minimum. 1 additional inch of every 3.3 FPM over 30 FPM (9 inches for 40 FPM). Refuge space with car top equipment (overhead machine?) Horizontal learance 3/4 inch minimum between car and hoistway. 1/2 inch minimum, 1 1/2 inch maximum between car and landing sill Pipes in Hoistway Pipes which present a danger when discharged are prohibited. (Most inspectors will prohibit any pipes that are not part of the elevator) Guarding of ables able passing through a floor or stairway, outside of the hoistway, must be guarded to reject a 1/2 inch ball. means of inspection must be provided. Floor openings can be no larger than required by the equipment Hoistway oors Swing or sliding doors are permitted. oors must be fire rated to conform to the local building code. oors must be strong enough to withstand 150 pounds/ force Maximum of 3 inches between the inside face of the door and the landing sill edge. Maximum of 5 inches between the inside face of the door and the car gate. No door hardware can project beyond the sill except for the interlock. oor must be equipped with a locking device. Interlocks must prevent movement of the car unless the door is closed and locked or closed only and locked within 6 inches of the landing. Interlocks must be listed by a certifying organization. It must be possible to open doors without reaching behind a car gate or wall. Sliding doors must be guarded against coming off of their track. Emergency access must be provided. Must not be accessible with common tools. ccess must not be located higher than 83 inches ar Enclosure Must be enclosed on all sides except for entrances. Must be secured to the platform. Must remain intact upon engagement of the safeties or buffer. Glass, plastic or acrylic panels must meet the applicable NSI Z97.1 standards. ll entrances must have a car gate. ar gates must be monitored by an electric contact Must be positively opened by a lever Maintained open by gravity or a spring esigned and located to not be accessible from inside the car Must prevent the car from moving unless the gate is within 2 inches of closed. light shall be provided activated by a switch or automatic means ar Frame and Platform metal car frame (sling) with a safety factor of 5 times the rated load shall be provided. Platforms shall be metal or laminated wood. If the car is provided with 2 way leveling, toe guards shall be provided (hydraulic units). Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 5

30 Section 5.3 Private Residence Elevators continued apacity, Loading, Speed and Rise Maximum net inside platform area is 15 square feet. For platforms up to and including 12 square feet, the capacity shall be a minimum of 40 pounds per square foot or 350 pounds, whichever is greater. For platforms over 12 square feet, the capacity shall be a minimum of 62.5 pounds per square foot. Rated speed shall not exceed 40 feet per minute. The rise shall not exceed 50 feet Safeties ar safeties are required Suspension Means Not less than two steel ropes. 1/4 inch minimum diameter for 500 pound units. 3/8 inch minimum diameter for units over 500 pounds capacity. Must have at least one spare rope turn on winding drums when the car is in the pit (Waupaca Elevator recommends at least 2). Rope ends must be clamped and secured from interference with equipment ounterweights Not applicable to Waupaca units uffers uffers are only required if there is occupiable space below the car Guide Rail Fastenings Mounting bolts shall be graded fasteners (Waupaca Elevator recommends grade 5) riving Machines, Sheaves and Their Supports Overhead driving machines and sheaves shall not be fastened to the underside of supporting beams. Residence elevators shall be arranged for manual operation in case of power failure. Instructions shall be posted near the manual operating device Terminal Stopping evices Upper and lower terminal stopping devices operated by the car shall be provided Upper and lower final terminal stopping devices operated by the car shall stop the car after it passes the terminal stopping device and before an obstruction is struck. slack rope switch may be used as a lower final terminal stopping device. Winding drum units require a machine operated terminal stopping device unless 2 top finals, one bottom final and a slack rope switch are provided. Final terminal stopping devices must prevent movement in both directions Operating evices Operation of the car shall be by continuous-pressure or automatic means. Exterior entrances shall be operated by a key switch. n emergency stop switch shall be provided in the car. Winding drum units require a slack rope device which must be reset manually Emergency Signaling evices telephone shall be installed in the car. n emergency signaling device, audible outside the hoistway, shall be provided Marking Plates capacity plate indicating rated load shall be inside the car. data plate shall be installed in the machinery area. The installer must complete the date installed Private Residence Hydraulic Elevators General Requirements Hoistway construction must meet the same basic standards as electric elevators riving Machines Not less than two steel ropes. Means shall be provided to prevent the ropes from leaving the sheave grooves. slack rope device which must be reset manually is required. Hydraulic piping must be of listed / certified grade. (Schedule 80 recommended by Waupaca Elevator) ccessible piping outside of the machine room or hoistway must be marked Elevator Hydraulic Line. Flexible hose shall not be installed within the hoistway or project through any walls. The pump relief valve shall be adjusted to prevent raising the pressure more than 50% above the working pressure at maximum capacity. The installer shall mark the working pressure on the pump data tag Terminal Stopping evices Upper and lower terminal stopping devices operated by the car shall be provided nticreep Leveling evice Each elevator shall be provided with an anticreep leveling device which will maintain the car within 1 inch of the landing. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 6

31 Waupaca Elevator SME Part 7 umbwaiter Synopsis Introduction This is a synopsis of the requirements most noteworthy to installers this is not a full list of all SME requirements. odes that do not apply to Waupaca designs are not included. Local codes and requirements may differ. Final interpretation and acceptance is subject to inspection by a code enforcing authority. 7.1 Power umbwaiters Hoistway Where required, fire resistive construction shall conform to the requirements of local building codes. Hoistway openings shall be protected by entrances having fire ratings in conformance to local building codes. The hoistway enclosure must be of sufficient strength to maintain true alignment of the landing doors and operating mechanisms Pits Pits are not required but shall be permitted ounterweights Not applicable to Waupaca units Vertical ar learances t the lowest limit of travel, the car shall not encounter an obstruction other then a buffer. t the highest limit of travel, the car shall not encounter an obstruction other then a mechanical stop or buffer Horizontal ar learances learance between the car and the enclosure shall be not less then 1/2 inch. learance between the car sill and landing sill shall be not less then 1/2 inch and not greater then 1 1/4 inch Protection of Spaces elow Hoistway ar safeties shall be provided. uffers shall be provided Machine Rooms and Spaces Where fire resistive construction is required by the local building code, the machine room shall be separated from the rest of the building by a fire resistive enclosure in conformance with the building code. umbwaiter equipment may be located in a room containing other equipment providing all moving parts are guarded. When the equipment is located in the bottom of the hoistway, the controller shall be outside the hoistway or on the inside face of the access door. means of access to machinery spaces shall be provided. ccess doors shall be provided with an electric contact. Permanent electric lighting shall be provided in all machine spaces Electrical Equipment Only electrical equipment for the dumbwaiter shall be permitted in the hoistway. Sprinklers shall be permitted in the hoistway. Pipes not related to the dumbwaiter operation shall not be permitted in the hoistway or machine spaces Machinery and Sheave eams Machines and sheaves shall be supported to prevent any part from becoming loose under the conditions imposed in service Guarding of Equipment In machine rooms, driving machines and sheaves shall be guarded to protect against accidental contact Hoistway Openings Landing openings shall be provided with entrances that guard the entire length and width of the opening. oors shall not open to a width or height greater than 1 inch more then the car opening. Entrances may be swing, horizontal slide, vertical slide biparting or vertical slide counterweighted. oors shall be kept closed except for the landing the car is located at. ccess doors with an electric contact, shall be permitted. Hoistway doors shall be provided with locking devices. Where vertical slide type entrances are used landing sills shall be of metal securely fastened to the building structure. Hoistway doors must withstand 250 pounds of force. Where required, rated doors shall be labeled accordingly. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 7

32 Part 7 umbwaiter continued oor Locking evices Interlocks must be listed by a certifying organization (EMI residential only). door unlocking device shall be provided at the top and bottom landing. Must not be accessible with common tools. ccess must not be located higher than 83 inches Power Operation of Hoistway oors Not applicable to Waupaca units Identification When multiple machines are located in the same machine room, they shall be so identified. 7.2 Electric umbwaiters ar Enclosures, Gates and Lighting The car shall be securely fastened to the point of suspension. The maximum inside height shall not exceed 48 inches. ar gates which guard the full width of the opening shall be provided at all entrances. Each gate shall be provided with an electric contact which will stop the car when the gate is opened more then 3/4 inches. Gate posts shall not enter into the access door area. Lighting is not required ar Frames and Platforms The car shall be guided on each guide rail by upper and lower guiding members apacity and Loading The rated load shall be not less than 13.9 pounds per cubic foot of inside car volume. metal capacity plate shall be provided. data plate shall be provided. The installer must complete the date installed. sign stating NO RIERS shall be located in the car ar Safeties ar safeties are not required unless there is accessible space below the hoistway (Waupaca Elevator requires safeties on all models) Speed Governors Not applicable to Waupaca units Suspension Means wire rope data tag shall be provided. Rope ends must be clamped and secured from interference with equipment. Must have at least one spare rope turn on winding drums when the car is in the pit ounterweights Not applicable to Waupaca units uffers and umpers ars shall be provided with buffers or bumpers. uffers shall be provided if there is accessible space below the hoistway Guide Rails and Fastenings Mounting bolts shall be graded fasteners (Waupaca Elevator recommends grade 5) riving Machines and Sheaves riving machines may be winding drum, traction, rack and pinion, screw column, belt drive, chain drive or hydraulic Terminal Stopping evices Upper and lower terminal stopping devices shall be provided. Upper and lower final terminal stopping devices operated by movement of the car shall stop the car after it passes the terminal stopping device and before an obstruction is struck. slack rope switch may be used as a lower final terminal stopping device. Final terminal stopping devices must prevent movement in both directions Operating evices Operation of the car shall be by continuous-pressure or automatic means. Winding drum units require a slack rope device which must be reset manually. ccess openings to the hoistway shall be provided with a locking device. The car sill shall stop vertically within 1/2 inches of the landing sill. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 3. 8

33 Waupaca Elevators Elevator ars Index Quick Reference Guide Standard ar Models ustom Raised Panel ars Raised Panel esigns omplete rochure... The elevators listed in the following section are based upon our standard car sizes. ustomization is possible contact, us for additional information. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 4. 1

34 Waupaca Elevator Quick Reference Guide - Elevator ars and Options esign Features esigner Heritage Estate Estate Ltd Interior Walls Standard irch Textured Loma Natural Hickory ustom Raised Panel** Oak herry See elow With standard 500 lbs. units, only the esigner ar is available: - irch - Oak - Maple Laminate (large selection) Optional N/ N/ N/ N/ Oak Optional Optional Trim Only Standard Optional Standard Maple, herry, Walnut or Mahogany Optional Optional Trim Only Optional Optional Standard Exotic woods as available N/ N/ N/ N/ Optional Interior Wall Textured Loma Unfinished/Nat. Estate Ltd. Unfinished/ Standard Unfinished Finishes * Natural Hickory Medium/ark lend Natural Lacquered (Standard unless car is unfinished) N/ Trim Only Standard Standard Standard ab Height Optional heights 6 10, 7 4 and 8 I 7 0 Std 7 0 Std 7 0 Std 7 0 Std 7 0 Std Flooring eiling Lighting Gates 1 sub floor to accomodate a 1/4 flooring provided by builder/owner 4 down lights (additional lights available) Ring olors: White, lack, hrome or rass ccordion - Solid Vinyl: halk, White, Natural Oak or Light Oak Standard Standard Standard Standard Standard irch Textured Textured Matches herry Loma Loma Walls Standard Standard Standard Optional Optional ccordion - Non Standard Vinyl, Wood or crylic Optional Optional Optional crylic Standard crylic Standard Hall Stations all with Fade Out In Use ( ar Here light is optional) Standard Standard Standard Standard Standard ar Operating Floor uttons, Light Switch, larm utton and Panel (OP) Emergency Stop Switch Standard Standard Standard Standard Standard Hall and OP #4 rushed Muntz or Stainless Steel Standard Standard Standard Optional Optional Finishes #8 Polished Muntz or Stainless Steel Optional Optional Optional Standard Standard Handrail Matching Wood Standard Standard Standard Optional Optional 1 per ar Polished or rushed, rass or hrome Optional Optional Optional Standard Standard Telephone Jack Standard Standard Standard Standard Standard Telephone ox Flush Wood over or #4 or #8 Muntz or Stainless Steel over with phone Optional Optional Optional Optional Optional Handrails #4 rushed rass Handrail w/ #8 Polished Ends & Standoffs #8 Polished rass Handrail w/ #8 Polished Ends & Standoffs #4 rushed hrome Handrail w/ #8 Polished Ends & Standoffs #8 Polished hrome Handrail w/ #8 Polished Ends & Standoffs Raised Panels hoose from Ten istinctive esigns or reate a ustom esign ** Raised Panel esigns are not available on 500 lbs. units * Interior Wall Wood Finishes esigner ar irch: Unfinished only irch, Walnut, Maple, Mahogany & Exotic Woods: Unfinished or Natural Oak: Unfinished, Natural, Medium or ark herry: Unfinished, Natural or Estate Ltd. lend Rv. 12/05/07 Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 4. 2

35 Waupaca Elevator Standard ar Models The esigner The Heritage Waupaca s basic provides quality with the opportunity to field-finish the car by painting, using wallpaper, etc. Standard features include: eiling height of 7 0 (inside dimension) Unfinished 3/4 Flush irch Walls or Melamine in Nat. Oak, Oak or White Unfinished irch eiling or White Melamine Two 4 recessed down-lights with white trim ring White, chalk, natural oak or light oak accordion gate Wood Handrail Unfinished Floor rushed Muntz or Stainless Steel ar onsole and Hall Stations Options vailable step up including the following features: eiling height of 7 0 (inside dimension) Neutral textured wall panels with natural finished hickory hardwood trim Neutral textured ceiling Two 4 recessed down-lights with white trim ring White, chalk, natural oak or light oak accordion gate Wood Handrail Unfinished Floor rushed Muntz or Stainless Steel ar onsole and Hall Stations Options vailable The Estate The Estate Ltd One of Waupaca s best selling designs; the Estate features: eiling height of 7 0 (inside dimension) Hand-Finished, eep Relief Oak Wall Panels (Walnut & herry optional) Neutral textured ceiling Two 4 recessed down-lights with white trim ring White, chalk, natural oak or light oak accordion gate Wood Handrail Unfinished Floor rushed Muntz or Stainless Steel ar onsole and Hall Stations Options vailable With a totally new elegant look, the Estate Limited includes these enhanced features: eiling height of 7 0 (inside dimension) Hand-Finished, Simulated Raised herry Wall Panels & eiling (walnut, oak or mahogany available) Four 4 recessed down-lights with brass trim ring crylic accordion gate (bronze or clear) Polished rass Handrail Polished rass Kickplate Unfinished Floor Polished Muntz ar onsole and Hall Stations Polished Stainless Steel Fixtures are available Options vailable Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 4. 3

36 Waupaca Elevator ustom Raised Panel ars herry Walnut and irds Eye Maple Walnut This sophisticated car, includes these luxurious features: eiling height of 7 0 (inside dimension) Hand-Finished, True Raised Wall and eiling Panels Four 4 recessed down-lights with brass trim rings crylic accordion gate (bronze or clear) Polished rass Handrail Polished rass Kickplate Unfinished Floor Polished Muntz ar onsole and Hall Stations Polished Stainless Steel fixtures are available Exotic woods when available are optional Raised Panel esigns hoose from one of these beautiful designs or we can customize it to your specifications. For additional information please contact your local dealer. Mix and match wood species or use only one wood species lder irch herry Hickory Mahogany Maple irds Eye Maple Oak Walnut dditional species are available please call your local dealer for prices and availability. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 4. 4

37 Waupaca Elevators rive Systems The rive System section was created to help you choose the drive system that is the best suited to your needs. dditional drive system information can be found behind each of the corresponding tabs. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 5. 1

38 Waupaca Elevator Quick Reference Guide Mechanical Features Weight apacity Travel / Stops up to.. up to... / up to... Standard 500 lbs. Winding rum PL 500 lbs. 1,000 lbs. Machine Roomless 1,000 lbs. 12 sq. ft. 12 sq. ft. 15 sq. ft. 15 sq. ft. 15 sq. ft. Hydraulic Model ustom-lift Paca-Lift Paca-Glide Paca-Ryde Excelevator Series ar Square Footage inside dimensions... up to... 1,000 lbs. 750 lbs. 950 lbs. 12 sq. ft. 15 sq. ft. 50 / 6 50 / 6 50 / 5 50 / 5 50 / 5 50 / 6 Speed Feet per Minute Pit epth Minimum depth Overhead above finished top floor w/ 6 10 I.. ab above finished top floor w/ 7 0 I.. ab above finished top floor w/ 7 4 I.. ab I..= Inside imensions above finished top floor w/ 8 I.. ab Minimum Travel Minimum travel allowed between stops Electrical 230 volts, single phase, 60 hertz Requirements (seperate 120-volt circuit required - car lighting) 30 mp 30 mp 30 mp 30 mp 30 mp 30 mp ontrols Magnetic Tape Reader and PL N/ Standard Standard Standard Standard Standard uto ar Lighting N/ Standard Standard Standard Standard Standard Homing Feature Elevator will return to a predetermined location when not in use. N/ Optional Standard Standard Standard Standard NEE FLOOR LOTION FIEL PROGRMMLE larm with Power Supply & Emergency Light Optional Optional Standard Standard Standard Standard with attery Standard Standard N/ N/ N/ N/ Easy Ryde N/ Standard Standard Standard 2 Speed Valve 2 Speed Valve Operation Manual Lowering evice On Standard Standard Standard Standard Standard Standard Gate Operator Emergency escent with attery utomatically opens & closes gate at landings N/ N/ Standard Standard Standard Standard N/ Optional Standard Standard Standard Optional Rv.02/20/08 Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page 5. 2

39 Waupaca Elevator rive Systems Winding rum Paca-Glide - Series 015-1,000 lbs. - Machine Roomless - Winding rum - igital ontrol System - dvanced Features - utomatic Gate Operator - J-Rail Paca-Lift - Series 018-1,000 lbs. - Winding rum - igital ontrol System - dvanced Features - utomatic Gate Operator -J-Rail Roped Hydraulic ustom Lift -Series 010 and lbs. - Winding rum - Very ependable - -Rail Paca-Ryde -Series 016-1,000 lbs. - Roped Hydraulic - igital ontrol System - dvanced Features - utomatic Gate Operator -J-Rail Excelevator - Series lbs., 950 lbs. - Roped Hydraulic -Smooth Ride - Quiet Ride -T-Rail These Illustrations are typical, your unit may vary. Waupaca Elevator ompany 1726 N. allard Road ppleton, WI Page /15/08

40 This page intentionally left blank

41 P - GLIE PITY - 1,000 lb. R SIZE - Maximum of 15 sq. ft. MHINE ROOMLESS WINING RUM ELETRI SUPPLY or 230 volts, single phase. separate 120-volt circuit is required for car lighting, 208 requires buck boost Series 015 TRVEL - up to 50 ft. STOPS - up to 5 stops SPEE - 40 feet per minute PIT EPTH - 6 minimum pit required, 8 recommended OVERHE - 24 minimum overhead clearance required above the car s inside dimension height (26 clearance recommended) GUIE RIL - Two 3/16 steel J-channel rails with 21 in between for a very smooth and stable ride MOTOR - inverter controlled, 3 HP GEROX - high ratio, direct mounted and coupled RUM - single drum with outboard bearing RKE - electrically released, spring applied SLK LE/ROKEN ROPE - twin instantaneous, broken and slack cable applied by retained compression spring LE - two 3/8 8 x 19 steel cables RIVE - variable speed frequency control for controlled acceleration and deceleration ONTROLS - fully automatic at car and landings, car light switch with auto light time out, emergency light, in-use indicator at landings, position indicator in car, field programmable, homing feature, modular car wiring, digitally addressed hoistway wiring SIGNL SYSTEMS - wall mount phone jack, emergency alarm MHINE LOTION - above rail in hoistway HOISTWY OOR INTERLOKS -required at each landing ONTROLLER LOTION - remote location outside of hoistway, locked control box EMERGENY LOWERING - manual hand wheel and battery powered emergency lowering R - Frameless car with power accordion gate standard ITIONL OPTIONS - are available, for details contact your local dealer. Packy T h e Wau pacader m THE WUP ELEVTOR OMPNY 06/08 Waupaca Elevator N. allard Road - ppleton, WI

42 This page intentionally left blank

43 Planning Guide Paca-Glide Elevator P-GLIE ELEVTOR PLNNING GUIE PMQ0300.1

44 P-GLIE ELEVTOR PLNNING GUIE PMQ0300.2

45 We are a proud member of the ccessibility Equipment Manufacturers ssociation. This symbol assures you of our commitment to high quality and accessibility to everyone. Waupaca Elevator Mission Statement Our company s mission is to supply and service products that meet or exceed our customers expectations of high quality, value, delivery and longevity. Our success is a direct reflection of our employees involvement and commitment to excellence. We strive to continuously improve our products to ensure meeting the future requirements of our customers and facilitate competitive growth. SI 3-Part Specifications ustomize and download SI 3-Part Specifications by logging on to: - specify Waupaca Elevator as the requested manufacturer - go to rchitect Section click on linking icon SpecWizard is a faster easier way to customize SI 3-part residential elevator specifications. Follow the above website information and choose the Spec Wizard icon. The drop down menus couldn t be any easier to use, just click on your choice of listed options and within a couple of minutes you have a completely customized specification. Table of ontents Introduction... 4 Minimum - Maximum imensions... 6 ar Opening onfigurations... 6 Hoistway Layout and imensions Hoistway Illustration Hoistway Specifications Elevation and Hoistway eiling Height ontroller/electrical Space Elevator Equipment Elevator Series 015 Illustration P-GLIE ELEVTOR PLNNING GUIE PMQ0300.3

46 Introduction This Planning Reference Guide is to be used as a guide in deciding the type of elevator to be installed, parameters of installation and steps taken to achieve a proper elevator installation. This guide may be used by the architect, contractor, dealer or home owner. The information in this guide is intended as an overview, each installation will have job specific specifications that must be followed. o not attempt to construct a hoistway on this information alone. Elevator installation is to be done by an authorized elevator contractor, and in accordance with installation instructions provided by the manufacturer. Installation must also be in compliance with requirements of the National Electric ode, merican Society of Mechanical Engineers safety code, and state and local building codes. Waupaca Elevator s products are designed to meet the requirements of SME National Elevator odes for residential elevators and are fully certified by a registered professional engineer. Waupaca Elevator ompany, Inc. elevators manufactured and installed under the proper parameters are warranted for 2 years. Manufacturer assumes no liability for equipment not installed in compliance with these codes. Planning Steps 1. - Locate local dealer and together determine the following: - Select drive system, car type and design specifications - ddress national, state and local code requirements - Hoistway size - ar size, layout and options E - Machine room location and layout (if required) F - Electrical requirements 2. - Obtain and follow site specific field drawings while building hoistway, doorways and any other construction related to the elevator oordinate with dealer to install elevator. P-GLIE ELEVTOR PLNNING GUIE PMQ0300.4

47 Paca-Glide Winding rum Elevator Machine Room Less Series 015 dvantages No Machine Room Required ecreased Installation Time dvanced Fieldbus Electrical System Reliable Quiet Operation Smooth Ride Emergency attery escent utomatic Gate Operator P-GLIE ELEVTOR PLNNING GUIE PMQ0300.5

48 Hoistway Layout - Paca-Glide Minimum and Maximum imensions Finished Hoistway 53-1/2" Minimum 2" 67" Maximum 2" Finished Hoistway 43-3/4" Minimum 61-3/4" Maximum 32" O.. Min. (50" O.. Max.) * 49-1/2" O.. Min. (** 63" O.. Max.) 7-3/4" 4-1/2" * Single Opening /4 O.. (outside dimension) minimum (rail is not centered in hoistway) ** Single Opening /2 O.. (outside dimensions) maximum NOTE: 1) Minimum dimensions reflect rail centered in hoistway 2) Minimum dimension for car without a gate recess is 36 O.. (outside dimension) 3) ar I.. (inside dimensions) can not exceed 15 sq. ft. for 1,000 lb. ar Opening onfigurations and oding Left Same Side Opening OE 1 Right Same Side Opening OE 2 Front Opening OE 3 Opposite Openings OE 4 Right djacent 90 Openings OE 5 Left djacent 90 Openings OE 6 1- The is the side on which the rail is attached. 2 - The first letter refers to the attachment location of the gate. 3 - The second letter refers to the location of the strike plate. 4 - If present, the third letter R denote a recessed gate. Opposite Openings R R Example: R R First Gate - R - gate attachment - strike plate R - recessed gate Second Gate - R - gate attachment - strike plate R - recessed gate P-GLIE ELEVTOR PLNNING GUIE PMQ0300.6

49 Hoistway Layout - Paca-Glide Use specified rail backing from architect to frame into wall. Hoistway illustrations below show finished dimensions. Finished hoistway dimensions include drywall, plaster and paint. maximum of 3 (see g below) are allowed between the closed hoistway door and the outer edge of the landing sill. etermine height of hall station by local code. Rough frame door in place with an extra inch of space on each side of the door to allow for door installation. The following examples are of a 1,000 lb. unit. Elevators are illustrated with accordion gates. The following layouts were designed for travel less than 25 feet, for distances up to 50 feet contact Waupaca Elevator o. These symbols are listed beside the car size Waupaca Elevator believes to be best suited for use by wheelchair passengers and their accompanying attendant. Recommended size for wheelchair passenger Recommended size for both wheelchair and attendant passengers R LEFT SME SIE OPENING OE 1 b c d R LEFT SME SIE OPENING OE 1 c b d e f g h i a e f g h i a ELEVTOR P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS HOISTWY FINISHE HOISTWY IMENSIONS LYOUT R SIZE a b c d e f g h i R 48" x 36" 50.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" OE 1 LEFT SME SIE OPENING OE 1 LEFT SME SIE OPENING R 54" x 40" 54.25" 60.5" 30.25" 24.5" 12.75" 36" 3" 54" 40" R 60" x 36" 50.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" R 48" x 36" R R 51.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" 54" x 40" 53.75" 60.5" 30.25" 24.5" 8.75" 36" 3" 54" 40" 60" x 36" 51.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" P-GLIE ELEVTOR PLNNING GUIE PMQ0300.7

50 Hoistway Layout - Paca-Glide R RIGHT SME SIE OPENING OE 2 b c d R RIGHT SME SIE OPENING OE 2 b c d a i h g e f a i h g e f ELEVTOR HOISTWY LYOUT OE 2 R RIGHT SME SIE OPENING R OE 2 RIGHT SME SIE OPENING R R R c b d P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS FINISHE HOISTWY IMENSIONS R SIZE a b c d e f g h i 48" x 36" 50.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" R 54" x 40" 54.25" 60.5" 30.25" 24.5" 12.75" 36" 3" 54" 40" 60" x 36" 48" x 36" 50.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" 51.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" 54" x 40" 53.75" 60.5" 30.25" 24.5" 8.75" 36" 3" 54" 40" 60" x 36" 51.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" d LEFT FRONT OPENING RIGHT FRONT OPENING OE 3 OE 3 b c a g h i i h g a ELEVTOR HOISTWY LYOUT OE 3 LEFT FRONT OPENING f e P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS R SIZE e FINISHE HOISTWY IMENSIONS a b c d e f g h i 48" x 36" 48.25" 56.5" 29.5" 24.5" 15" 36" 3" 48" 36" 54" x 40" 52.25" 62.5" 32.5" 24.5" 21" 36" 3" 54" 40" 60" x 36" 48.25" 68.5" 35.5" 24.5" 27" 36" 3" 60" 36" f OE 3 RIGHT FRONT OPENING 48" x 36" 48.25" 56.5" 29.5" 24.5" 15" 36" 3" 48" 36" 54" x 40" 52.25" 62.5" 32.5" 24.5" 21" 36" 3" 54" 40" 60" x 36" 48.25" 68.5" 35.5" 24.5" 27" 36" 3" 60" 36" P-GLIE ELEVTOR PLNNING GUIE PMQ0300.8

51 Hoistway Layout - Paca-Glide a R - R b c d h i g R - R OPPOSITE OPENING OPPOSITE OPENING OE 4 OE 4 b d e f a i h c g e f ELEVTOR HOISTWY LYOUT OE 4 OPPOSITE OPENING OE 4 a b c d e f g h i R-R 48" x 36" 50.25" 55" 27.50" 24.5" 8.75" 36" 3" 48" 36" R-R R-R R-R P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS R SIZE FINISHE HOISTWY IMENSIONS 54" x 40" 54.25" 61" 30.50" 24.5" 12.75" 36" 3" 54" 40" 60" x 36" 50.25" 67" 33.50" 24.5" 8.75" 36" 3" 60" 36" 48" x 36" 51.25" 55" 27.50" 24.5" 8.75" 36" 3" 48" 36" OPPOSITE OPENING R-R R-R 54" x 40" 53.75" 61" 30.50" 24.5" 8.75" 36" 3" 54" 40" 60" x 36" 51.25" 67" 33.50" 24.5" 8.75" 36" 3" 60" 36" b R RIGHT JENT 90 OPENINGS OE 5 d c R- LEFT JENT 90 OPENINGS OE 6 c d b a ii h g e f e f g h ii a ELEVTOR HOISTWY LYOUT OE 5 RIGHT JENT 90 OPENING OE 6 LEFT JENT 90 OPENING R- R- R- R- R- R- k j R SIZE P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS 48" x 36" 48.25" 56.5" 27.25" 24.5" 8.5" 32" 3" 48" 36" 15.5" 54" x 40" 60" x 36" 48" x 36" 48.25" 56.5" 27.25" 24.5" 8.5" 32" 3" 48" 36" 15.5" 36" 54" x 40" 60" x 36" j a b c d e f g h i j k k FINISHE HOISTWY IMENSIONS 52.25" 62.5" 30.25" 24.5" 8.5" 36" 3" 54" 40" 21.5" 36" 48.25" 68.5" 33.25" 24.5" 8.5" 32" 3" 60" 36" 27.5" 36" 52.25" 62.5" 30.25" 24.5" 8.5" 36" 3" 54" 40" 21.5" 36" 48.25" 68.5" 33.25" 24.5" 8.5" 32" 3" 60" 36" 27.5" 36" 36" P-GLIE ELEVTOR PLNNING GUIE PMQ0300.9

52 Hoistway Illustrations - Paca-Glide The typical layouts shown here may vary from your actual hoistway. The purpose of these layouts are for a general understanding. Please refer to the Waupaca Elevator drawings and specifications that will be provided by the company. This example applies to units with up to 25 of travel. ontact Waupaca Elevator for requirements on units traveling over 25. OVERHE LERNE FLOOR HEIGHT HOISTWY OPENING HOISTWY OPENING TOP PLTE TRUSS LMINTE VENEER LUMER OTTOM PLTE FLOOR JOIST HEER STU PIT FLOOR ENTER LINE Of RIL WLL 12-1/4" 12-1/4" 34" 17" 17" TOTL R TRVEL PIT EXMPLE OF ROUGH FRME HOISTWY WITHOUT RYWLL OORWY (4) 1-3/4" X 9-1/2" LMINTE VENEER LUMER (LVL) EXMPLE OF TYPIL LYOUT These drawings depict sample construction only. It is the responsibility of the installer/contractor or engineer to design and specify structural supports. ll construction to be in compliance with local codes. PIT P-GLIE ELEVTOR PLNNING GUIE PMQ

53 Hoistway Specifications - Paca-Glide Refer to Illustration on previous page TTENTION ONSTRUTION ONTRTOR: This is an example of a winding drum hoistway. Job specific documentation will be provided by Waupaca Elevator from which to construct the hoistway. Hoistway onstruction Requirements (to be completed prior to elevator installation by contractor) 1. Electrical Requirements: - edicated 230 V 30 MP ircuit Single Phase. Fuse should be a time delay 25 MP. - Power supply to be installed in a lockable fused disconnect V 15 mp ircuit Single Phase with manual disconnect & 15 MP protection. - Electrical wiring to comply with applicable codes. 2. Unfinished/Un-installed oor - Installation company may prefer a minimum of one hoistway door and associated framing be left unfinished/un-installed to accommodate elevator installation equipment and to prevent accidental damage to door and framing (preferably at grade level). 3. Plumb and Square Hoistway - Hoistway must be plumb within 1/8 inch per 10 ft. of height and square at any point within 1/4 inch based on difference in diagonal measurements. 4. Supportive Structure - Structure must be capable of supporting the appropriate loads. Local engineering support is recommended. 5. Telephone onnection - ode requires a telephone connection to the elevator car, therefore, a phone line must be installed leading to the controller. 6. SME 17.1 Part Hoistway to be constructed in accordance with SME17.1 Part 5.3 and all local codes. 7. Hoistway oor Security (Interlocks) - ll hoistway doors require interlocks as well as a door handle and a latch set. Interlocks will be installed by the elevator installers. Waupaca Elevator recommends the use of solid core doors. 8. Temperature Requirements - Hoistway and machine room temperature should be maintainable between 60 F- 110 F and should not be exposed to the elements. 9. No lterations - ny alterations to the equipment without written authorization by Waupaca Elevator will void all warranties. 10. Pit Floor Strength - pit floor must be designed to withstand a load of 4,000 lbs. When used, concrete must be a minimum of 4 thick and rated at 3500PSI. P-GLIE ELEVTOR PLNNING GUIE PMQ

54 Elevation and Hoistway eiling Heights - Paca-Glide Since the Paca-Glide Power Unit sits on top of the rail, the hoistway will need to be taller than other winding drum or hydraulic units. ccess oor Location Minimum Hoistway eiling Height Top Floor dditional Floors Structure required to support lifting drive and rail during installation. Locate near center of shaft (by others) minimum 1,000 lbs. dditional space may be required for hoisting and maneuvering equipment into place. Waupaca Elevator will provide you with the appropriate dimensions. Waupaca Elevator s Paca Glide offers a total of five stops and a total travel distance of 50 feet. Hoistway eiling Heights* Inside ab imension Inside ab imension Total Travel Recommended eiling Height Minimum eiling Height * ustom sized cabs will alter these dimensions. Waupaca Elevator will provide you with the appropriate dimensions. First floor Pit epth Recommended 8" Minimum 6" P-GLIE ELEVTOR PLNNING GUIE PMQ

55 ontroller Space - Paca-Glide Typical Layout 24"- MINIMUM OVERHE 26"- REOMMENE OVERHE 7' STNR R HEIGHT 50' MXIMUM TRVEL LENGTH 18" MINIMUM TRVEL ETWEEN FLOORS 1. The ontroller requires a clear minimum space of 36 x 30 located directly in front of the controller (refer to illustration). 2. lockable service disconnect must be placed within sight of the controller and must be easily accessible, from the latch side of the doorway (if door is present). 3. ontroller Space must be provided for the operating equipment that meets national electrical code clear space requirements and all local codes. Must provide a convenience outlet and light with switch. Temperatures must be maintained between F (with a relative humidity not to exceed 95%). 6" MINIMUM PIT EPTH 8" REOMMENE PIT EPTH ONTROLLER SIZE STNR 24" x 18" x 8" TTERY LOWERING 12" x 16" x 8" ONTROLLER - NORMLLY SURFE MOUNTE 36" 30" ISONNET P-GLIE ELEVTOR PLNNING GUIE PMQ

56 Elevator Equipment - Paca-Glide Typical Powerhead Interlocks Main Rail Motor Gear ox rum MOTOR - SINGLE SPEE, 3 HORSEPOWER, INSTNT REVERSING. RUM - SINGLE RUM WITH OUTOR ERING FOR SUPPORT. STOPPING EVIES MGNETI TPE REER FOR LEVELING URY & TOP FINL LIMIT SWITH. GER OX - HIGH RTIO, IRET MOUNTE N OUPLE L. 300 LS. MX. TENSION PER FSTENER EMI - III INTERLOK 300 LS. MX. SHER PER FSTENER RIL HOISTWY OOR INTERLOKS EMI required at each opening to prevent hoistway or elevator access while elevator is operating or at another landing. P-GLIE ELEVTOR PLNNING GUIE PMQ

57 Paca-Glide Elevator Series 015 POWERHE HN WHEEL STEEL TPE FINL LIMIT M WIRE ROPE RIL R STILIZER RKETS RIL RKET SHKLES SLING EXTENSIONS KING SLING FINL LIMITS ONTROLLER LIGHTS EMI INTERLOK ISONNET TTERY LOWERING GTE OPERTOR R TOP OX R HLL STTION ORIN GTE R OPERTING PNEL GTE TRK P-GLIE ELEVTOR PLNNING GUIE PMQ

58 PMQ0300- PRIL North allard Road ppleton, WI Phone P-GLIE ELEVTOR PLNNING GUIE PMQ

59 P - LIFT WINING RUM RESIENTIL ELEVTOR Series 018 PITY - 1,000 lb. R SIZE - Maximum of 15 sq. ft. TRVEL - up to 50 ft. STOPS - up to 5 stops SPEE - 40 feet per minute PIT EPTH - 6 minimum pit required, 8 recommended OVERHE - 12 minimum overhead clearance required above the car s inside dimension height GUIE RIL - Two 3/16 steel J-channel rails with 21 in between for a very smooth and stable ride MOTOR - inverter controlled, 3 HP GEROX - high ratio, direct mounted and coupled RUM - single drum with outboard bearing RKE - electrically released, spring applied SLK LE/ROKEN ROPE - twin instantaneous, broken and slack cable applied by retained compression spring ELETRI SUPPLY or 230 volts, single phase. separate 120-volt circuit is required for car lighting, 208 requires buck boost RIVE - variable speed frequency control for controlled acceleration and deceleration ONTROLS - fully automatic at car and landings, car light switch with auto light time out, emergency light, in-use indicator at landings, position indicator in car, field programmable, homing feature, modular car wiring, digitally addressed hoistway wiring SIGNL SYSTEMS - wall mount phone jack, emergency alarm MHINE LOTION - multiple remote locations HOISTWY OOR INTERLOKS - required at each landing ONTROLLER LOTION - remote location outside of hoistway, locked control box EMERGENY LOWERING - manual hand wheel and battery powered emergency lowering R - Frameless car with power accordion gate standard ITIONL OPTIONS - are available, for details contact your local dealer. LE - two 3/8 8 x 19 steel cables Packy T h e Wau pacader m THE WUP ELEVTOR OMPNY 01/ N. allard Road - ppleton, WI

60 This page intentionally left blank

61 Planning Guide Paca-Lift Elevator P-LIFT ELEVTOR PLNNING GUIE PMQ0600.1

62 P-LIFT ELEVTOR PLNNING GUIE PMQ0600.2

63 We are a proud member of the ccessibility Equipment Manufacturers ssociation. This symbol assures you of our commitment to high quality and accessibility to everyone. Waupaca Elevator Mission Statement Our company s mission is to supply and service products that meet or exceed our customers expectations of high quality, value, delivery and longevity. Our success is a direct reflection of our employees involvement and commitment to excellence. We strive to continuously improve our products to ensure meeting the future requirements of our customers and facilitate competitive growth. SI 3-Part Specifications ustomize and download SI 3-Part Specifications by logging on to: - specify Waupaca Elevator as the requested manufacturer - go to rchitect Section click on linking icon SpecWizard is a faster easier way to customize SI 3-part residential elevator specifications. Follow the above website information and choose the Spec Wizard icon. The drop down menus couldn t be any easier to use, just click on your choice of listed options and within a couple of minutes you have a completely customized specification. Table of ontents Introduction... 4 Minimum and Maximum imensions... 6 ar Opening onfigurations... 6 Hoistway Layout Hoistway Illustration Hoistway Specifications eiling Height and Elevation ontroller/electrical Space Elevator Equipment Elevator Series P-LIFT ELEVTOR PLNNING GUIE PMQ0600.3

64 Introduction This Planning Reference Guide is to be used as a guide to determine parameters of installation and steps taken to achieve a proper elevator installation. This guide may be used by the architect, contractor, dealer or home owner. The information in this guide is intended as an overview, each installation will have job specific specifications that must be followed. o not attempt to construct a hoistway on this information alone. Elevator installation is to be done by an authorized elevator contractor, and in accordance with installation instructions provided by the manufacturer. Installation must also be in compliance with requirements of the National Electric ode, merican Society of Mechanical Engineers safety code, and state and local building codes. Waupaca Elevator s products are designed to meet the requirements of SME National Elevator odes for residential elevators and are fully certified by a registered professional engineer. Waupaca Elevator ompany, Inc. elevators manufactured and installed under the proper parameters are warranted for 2 years. Manufacturer assumes no liability for equipment not installed in compliance with these codes. Planning Steps 1. - Locate local dealer and together determine the following: - Select drive system, car type and design specifications - ddress national, state and local code requirements - Hoistway size - ar size, layout and options E - Machine room location and layout F - Electrical requirements 2. - Obtain and follow site specific field drawings while building hoistway, doorways and any other construction related to the elevator oordinate with dealer to install elevator. P-LIFT ELEVTOR PLNNING GUIE PMQ0600.4

65 Paca-Lift Winding rum Elevator Series 018 dvantages Limited Machine Room Space ecreased Installation Time dvanced Fieldbus Electrical System Reliable Quiet Operation Smooth Ride Emergency attery escent utomatic Gate Operator P-LIFT ELEVTOR PLNNING GUIE PMQ0600.5

66 Hoistway Layout - Paca-Lift Minimum and Maximum imensions Finished Hoistway 53-1/2" Minimum 2" 67" Maximum 2" Finished Hoistway 43-3/4" Minimum 61-3/4" Maximum 32" O.. Min. (50" O.. Max.) * 49-1/2" O.. Min. (** 63" O.. Max.) 7-3/4" 4-1/2" * Single Opening /4 O.. (outside dimension) minimum (rail is not centered in hoistway) ** Single Opening /2 O.. (outside dimensions) maximum NOTE: 1) Minimum dimensions reflect rail centered in hoistway 2) Minimum dimension for car without a gate recess is 36 O.. (outside dimension) 3) ar I.. (inside dimensions) can not exceed 15 sq. ft. for 1,000 lb. ar Opening onfigurations and oding Left Same Side Opening OE 1 Right Same Side Opening OE 2 Front Opening OE 3 Opposite Openings OE 4 Right djacent 90 Openings OE 5 Left djacent 90 Openings OE 6 1- The is the side on which the rail is mounted. 2 - The first letter refers to the attachment location of the gate. 3 - The second letter refers to the location of the strike plate. 4 - If present, the third letter R denotes a recessed gate. Opposite Openings R R Example: R R First Gate - R - gate attachment - strike plate R - recessed gate Second Gate - R - gate attachment - strike plate R - recessed gate P-LIFT ELEVTOR PLNNING GUIE PMQ0600.6

67 Hoistway Layout - Paca-Lift Use specified rail backing from architect to frame into wall. Hoistways illustrations below show finished dimensions. Finished hoistway dimensions include drywall, plaster and paint. maximum of 3 (see g below) are allowed between the closed hoistway door and the outer edge of the landing sill. etermine height of hall station by local code. Rough frame door in place with an extra inch of space on each side of the door to allow for door installation. The following examples are of a 1,000 lb. unit. Elevators are illustrated with accordion gates. These symbols are listed beside the car size Waupaca Elevator believes to be best suited for use by wheelchair passengers and their accompanying attendant. Recommended size for wheelchair passenger Recommended size for both wheelchair and attendant passengers R LEFT SME SIE OPENING OE 1 b c d R LEFT SME SIE OPENING OE 1 c b d e f g h i a e f g h i a ELEVTOR P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS HOISTWY FINISHE HOISTWY IMENSIONS LYOUT R SIZE a b c d e f g h i R 48" x 36" 50.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" OE 1 LEFT SME SIE OPENING OE 1 LEFT SME SIE OPENING R 54" x 40" 54.25" 60.5" 30.25" 24.5" 12.75" 36" 3" 54" 40" R 60" x 36" 50.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" R 48" x 36" R R 51.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" 54" x 40" 53.75" 60.5" 30.25" 24.5" 8.75" 36" 3" 54" 40" 60" x 36" 51.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" P-LIFT ELEVTOR PLNNING GUIE PMQ0600.7

68 Hoistway Layout - Paca-Lift R RIGHT SME SIE OPENING OE 2 b c d R RIGHT SME SIE OPENING OE 2 b c d a i h g e f a i h g e f ELEVTOR HOISTWY LYOUT OE 2 RIGHT SME SIE OPENING OE 2 RIGHT SME SIE OPENING R R R R c b d P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS R SIZE 48" x 36" FINISHE HOISTWY IMENSIONS a b c d e f g h i R 54" x 40" 54.25" 60.5" 30.25" 24.5" 12.75" 36" 3" 54" 40" R 48" x 36" 50.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" 60" x 36" 50.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" 51.25" 54.5" 27.25" 24.5" 8.75" 36" 3" 48" 36" 54" x 40" 53.75" 60.5" 30.25" 24.5" 8.75" 36" 3" 54" 40" 60" x 36" 51.25" 66.5" 33.25" 24.5" 8.75" 36" 3" 60" 36" d LEFT FRONT OPENING RIGHT FRONT OPENING OE 3 OE 3 b c a g h i i h g a ELEVTOR HOISTWY LYOUT OE 3 LEFT FRONT OPENING f e P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS R SIZE e FINISHE HOISTWY IMENSIONS a b c d e f g h i 48" x 36" 48.25" 56.5" 29.5" 24.5" 15" 36" 3" 48" 36" 54" x 40" 52.25" 62.5" 32.5" 24.5" 21" 36" 3" 54" 40" 60" x 36" 48.25" 68.5" 35.5" 24.5" 27" 36" 3" 60" 36" f OE 3 RIGHT FRONT OPENING 48" x 36" 48.25" 56.5" 29.5" 24.5" 15" 36" 3" 48" 36" 54" x 40" 52.25" 62.5" 32.5" 24.5" 21" 36" 3" 54" 40" 60" x 36" 48.25" 68.5" 35.5" 24.5" 27" 36" 3" 60" 36" P-LIFT ELEVTOR PLNNING GUIE PMQ0600.8

69 Hoistway Layout - Paca-Lift a R - R b c d h i g R - R OPPOSITE OPENING OPPOSITE OPENING OE 4 OE 4 b d e f a i h c g e f ELEVTOR HOISTWY LYOUT OE 4 OPPOSITE OPENING OE 4 a b c d e f g h i R-R 48" x 36" 50.25" 55" 27.50" 24.5" 8.75" 36" 3" 48" 36" R-R R-R R-R P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS R SIZE FINISHE HOISTWY IMENSIONS 54" x 40" 54.25" 61" 30.50" 24.5" 12.75" 36" 3" 54" 40" 60" x 36" 50.25" 67" 33.50" 24.5" 8.75" 36" 3" 60" 36" 48" x 36" 51.25" 55" 27.50" 24.5" 8.75" 36" 3" 48" 36" OPPOSITE OPENING R-R R-R 54" x 40" 53.75" 61" 30.50" 24.5" 8.75" 36" 3" 54" 40" 60" x 36" 51.25" 67" 33.50" 24.5" 8.75" 36" 3" 60" 36" b R RIGHT JENT 90 OPENINGS OE 5 d c R- LEFT JENT 90 OPENINGS OE 6 c d b a ii h g e f e f g h ii a ELEVTOR HOISTWY LYOUT OE 5 RIGHT JENT 90 OPENING OE 6 LEFT JENT 90 OPENING R- R- R- R- R- R- k j R SIZE P GLIE/LIFT ELEVTOR HOISTWY IMENSIONS 48" x 36" 48.25" 56.5" 27.25" 24.5" 8.5" 32" 3" 48" 36" 15.5" 54" x 40" 60" x 36" 48" x 36" 48.25" 56.5" 27.25" 24.5" 8.5" 32" 3" 48" 36" 15.5" 36" 54" x 40" 60" x 36" j a b c d e f g h i j k k FINISHE HOISTWY IMENSIONS 52.25" 62.5" 30.25" 24.5" 8.5" 36" 3" 54" 40" 21.5" 36" 48.25" 68.5" 33.25" 24.5" 8.5" 32" 3" 60" 36" 27.5" 36" 52.25" 62.5" 30.25" 24.5" 8.5" 36" 3" 54" 40" 21.5" 36" 48.25" 68.5" 33.25" 24.5" 8.5" 32" 3" 60" 36" 27.5" 36" 36" P-LIFT ELEVTOR PLNNING GUIE PMQ0600.9

70 Hoistway Illustration - Paca-Lift TOP PLTE The typical layouts shown here may vary from your actual hoistway. The purpose of these layouts are for a general understanding. Please refer to the Waupaca Elevator drawings and specifications that will be provided by the company. OVERHE LERNE HOISTWY OPENING TRUSS LMINTE VENEER LUMER OTTOM PLTE FLOOR JOIST HEER FLOOR HEIGHT STU HOISTWY OPENING PIT FLOOR ENTER LINE Of RIL WLL 13-3/4" 13-3/4" 37" 18-1/2" 18-1/2" TOTL R TRVEL PIT EXMPLE OF ROUGH FRME HOISTWY WITHOUT RYWLL OORWY (4) 1-3/4" X 9-1/2" LMINTE VENEER LUMER (LVL) USE TO NHOR RIL RKETS EXMPLE OF TYPIL LYOUT These drawings depict sample construction only. It is the responsibility of the installer/contractor or engineer to design and specify structural supports. ll construction to be in compliance with local codes. PIT P-LIFT ELEVTOR PLNNING GUIE PMQ

71 Hoistway Specifications - Paca-Lift Refer to Illustration on previous page TTENTION ONSTRUTION ONTRTOR: This is an example of a winding drum hoistway. Job specific documentation will be provided by Waupaca Elevator from which to construct the hoistway. Hoistway onstruction Requirements (to be completed prior to elevator installation by contractor) 1. Electrical Requirements: - edicated 230 V 30 MP ircuit Single Phase with a 25 MP slow blow fuse. - Power supply to be installed in a lockable fused disconnect V 15 mp ircuit Single Phase with manual disconnect & 15 MP protection. - Electrical wiring to comply with applicable codes. 2. Unfinished/Un-installed oor - Installation company may prefer a minimum of one hoistway door and associated framing be left unfinished/un-installed to accommodate elevator installation equipment and to prevent accidental damage to door and framing (preferably at grade level). 3. Plumb and Square Hoistway - Hoistway must be plumb within 1/8 inch per 10 ft. of height and square at any point within 1/4 inch based on difference in diagonal measurements. 4. Supportive Structure - Structure must be capable of supporting the appropriate loads. Local engineering support is recommended. 5. Telephone onnection - ode requires a telephone connection to the elevator car, therefore, a phone line must be installed leading to the controller. 6. SME 17.1 Part Hoistway to be constructed in accordance with SME17.1 Part 5.3 and all local codes. 7. Hoistway oor Security (Interlocks) - ll hoistway doors require interlocks as well as a door handle and a latch set. Interlocks will be installed by the elevator installers. Waupaca Elevator recommends the use of solid core doors. 8. Temperature Requirements - Hoistway and machine room temperature should be maintainable between 60 F- 110 F and should not be exposed to the elements. 9. No lterations - ny alterations to the equipment without written authorization by Waupaca Elevator will void all warranties. 10. Pit Floor Strength - pit floor must be designed to withstand a load of 4,000 lbs. When used, concrete must be a minimum of 4 thick and rated at 3500PSI. P-LIFT ELEVTOR PLNNING GUIE PMQ

72 Elevation and Hoistway eiling Heights - Paca-Lift Waupaca Elevator s Paca Lift offers a total of five stops and a total travel distance of 50 feet. Minimum Hoistway eiling Height Top Floor dditional Floors Inside ab imension Minimum Hoistway eiling Height Minimum Hoistway eiling Heights* * ustom sized cabs will alter these dimensions. Waupaca Elevator will provide you with the appropriate dimensions. Inside ab imension Total Travel Pit epth When the machine is located in the pit, the minimum pit depth is 24. ll other layouts require a minimum of 6 but 8 is recommended. First Floor Pit epth Recommended 8" - Minimum 6" P-LIFT ELEVTOR PLNNING GUIE PMQ

73 ontroller Space - Paca-Lift Typical Layout 12" MINIMUM OVERHE 7'-0" STNR R HEIGHT 50' MXIMUM TRVEL LENGTH 18" MINIMUM TRVEL ETWEEN FLOORS 6" MINIMUM PIT EPTH 8" REOMMENE PIT EPTH ONTROLLER SIZE STNR 24" x 18" x 8" SURFE MOUNTE 1. The ontroller requires minimum clear space of 30 x 36 located directly in front of the controller (refer to illustration). 2. lockable service disconnect must be placed within sight of the controller and must be easily accessible, from the latch side of the doorway (if door is present). 3. ontroller Space must be provided for the operating equipment that meets national electrical code clear space requirements and all local codes. Must provide a convenience outlet and light with switch. Temperatures must be maintained between F (with a relative humidity not to exceed 95%). ISONNET 30" 36" P-LIFT ELEVTOR PLNNING GUIE PMQ

74 Elevator Equipment - Paca-Lift Typical Powerhead Interlocks Main Rail Motor Gear ox rum GER OX - HIGH RTIO, IRET MOUNTE N OUPLE. MOTOR - III Phase, 3 HORSEPOWER, INSTNT REVERSING L. STOPPING EVIES MGNETI TPE REER FOR LEVELING URY & TOP FINL LIMIT SWITHES. 300 L. RUM - SINGLE RUM WITH OUTOR ERING FOR SUPPORT. RIL 300 LS. MX. TENSION PER FSTENER EMI - III INTERLOK 300 LS. MX. SHER PER FSTENER HOISTWY OOR INTERLOKS EMI required at each opening to prevent hoistway or elevator access while elevator is operating. Travel Sheaves 2000 lb. PIT TRVELING 2000 lb lb. IVERTER 2000 lb. OVERHE TRVELING 2000 lb lb lb lb lb. (TO RIL) 2000 lb lb. TRVELING FLOOR JENT MHINE ROOM WLL SHEVE TRVELING SHEVE P-LIFT ELEVTOR PLNNING GUIE PMQ

75 Paca-Lift Elevator Series 018 HN WHEEL RIL RKET WIRE ROPE STEEL TPE POWERHE FINL LIMIT M RIL R STILIZER RKETS SLING EXTENSIONS KING SHKLES SLING GTE OPERTOR ISONNET FINL LIMITS R TOP OX LIGHTS ONTROLLER R EMI INTERLOK HLL STTION ORIN GTE GTE TRK R OPERTING PNEL P-LIFT ELEVTOR PLNNING GUIE PMQ

76 PMQ North allard Road ppleton, WI MRH 2009 Phone P-LIFT ELEVTOR PLNNING GUIE PMQ

77 P - RYE ROPE HYRULI RESIENTIL ELEVTOR S Series 016 PITY - 1,000 lbs. R SIZE - Maximum of 15 sq. ft. TRVEL - up to 50 ft. STOPS - up to 5 stops SPEE - 40 feet per minute PIT EPTH - 8 minimum pit required OVERHE - 18" above top floor with standard 7'-0" I.. car (additional overhead required with some options). GUIE RIL - Two 3/16 steel J-channel rails with 21 in between for a very smooth and stable ride PUMP UNIT -rotary screw type with submersed motor MOTOR -single speed, 2HP VLVE -2 speed SLK LE/ROKEN ROPE - twin instantaneous, broken and slack cable applied by retained compression spring LE - two 3/8 8 x 19 steel cables ELETRI SUPPLY -208/ 230 volts, single phase, 60 hertz with 3 pole disconnect switch. separate 120-volt circuit is required for car lighting ONTROLS - fully automatic at car and landings, car light switch with auto light time out, emergency light, in-use indicator at landings, position indicator in car, field programmable homing feature, modular car wiring, digitally addressed hoistway wiring SIGNL SYSTEMS - wall mount phone jack, emergency alarm HOISTWY OOR INTERLOKS -required at each landing EMERGENY LOWERING -automatic descent with back-up power supply R - Frameless car with power accordion gate standard ITIONL OPTIONS - are available, for details contact your local dealer. Packy T h e Wau pacader m THE WUP ELEVTOR OMPNY 02/ N. allard Road - ppleton, WI

78 This page intentionally left blank

79 Planning Guide Paca-Ryde Elevator P-RYE ELEVTOR PLNNING GUIE PMQ0500.1

80 P-RYE ELEVTOR PLNNING GUIE PMQ0500.2

81 We are a proud member of the ccessibility Equipment Manufacturers ssociation. This symbol assures you of our commitment to high quality and accessibility to everyone. Waupaca Elevator Mission Statement Our company s mission is to supply and service products that meet or exceed our customers expectations of high quality, value, delivery and longevity. Our success is a direct reflection of our employees involvement and commitment to excellence. We strive to continuously improve our products to ensure meeting the future requirements of our customers and facilitate competitive growth. SI 3-Part Specifications ustomize and download SI 3-Part Specifications by logging on to: - specify Waupaca Elevator as the requested manufacturer - go to rchitect Section click on linking icon Spec Wizard is a faster easier way to customize SI 3-part residential elevator specifications. Follow the above website information and choose the Spec Wizard icon. The drop down menus couldn t be any easier to use, just click on your choice of listed options and within a couple of minutes you have a completely customized spec. Table of ontents Introduction... 4 Minimum - Maximum imensions... 6 ar Opening onfigurations... 6 Hoistway Layout Hoistway Illustration Hoistway Specifications Elevation and Hoistway eiling Height ontroller/electrical Space Elevator Equipment Elevator Series 016 Illustration P-RYE ELEVTOR PLNNING GUIE PMQ0500.3

82 Introduction This Planning Reference Guide is to be used as a guide in deciding the type of elevator to be installed, parameters of installation and steps taken to achieve a proper elevator installation. This guide may be used by the architect, contractor, dealer or home owner. The information in this guide is intended as an overview, each installation will have job specific specifications that must be followed. o not attempt to construct a hoistway on this information alone. Elevator installation is to be done by an authorized elevator contractor, and in accordance with installation instructions provided by the manufacturer. Installation must also be in compliance with requirements of the National Electric ode, merican Society of Mechanical Engineers safety code, and state and local building codes. Waupaca Elevator s products are designed to meet the requirements of SME National Elevator odes for residential elevators and are fully certified by a registered professional engineer. Waupaca Elevator ompany, Inc. elevators manufactured and installed under the proper parameters are warranted for 2 years. Manufacturer assumes no liability for equipment not installed in compliance with these codes. Planning Steps 1. - Locate local dealer and together determine the following: - Select drive system, car type and design specifications - ddress national, state and local code requirements - Hoistway size - ar size, layout and options E - Machine room location and layout (if required) F - Electrical requirements 2. - Obtain and follow site specific field drawings while building hoistway, doorways and any other construction related to the elevator oordinate with dealer to install elevator. P-RYE ELEVTOR PLNNING GUIE PMQ0500.4

83 Paca-Ryde Hydraulic Elevator Series 016 dvantages Minimal Machine Room Space ecreased Installation Time dvanced Fieldbus Electrical System Reliable Quiet Operation Smooth Ride Emergency attery escent utomatic Gate Operator P-RYE ELEVTOR PLNNING GUIE PMQ0500.5

84 Hoistway Layout - Paca-Ryde Minimum and Maximum imensions Finished Hoistway 53-1/2" Minimum 2" 67" Maximum 2" Finished Hoistway 46-1/4" Minimum 64-1/4" Maximum * 49-1/2" O.. Min. (** 63" O.. Max.) 32" O.. Min. (50" O.. Max.) 9-3/4" 4-1/2" * Single Opening /4 O.. (outside dimension) minimum (rail is not centered in hoistway) ** Single Opening /2 O.. (outside dimensions) maximum NOTE: 1) Minimum dimensions reflect rail centered in hoistway 2) Minimum dimension for car without a gate recess is 36 O.. (outside dimension) 3) ar I.. (inside dimensions) can not exceed 15 sq. ft. for 1,000 lb. ar Opening onfigurations and oding Left Same Side Opening OE 1 Right Same Side Opening OE 2 Front Opening OE 3 Opposite Openings OE 4 Right djacent 90 Openings OE 5 Left djacent 90 Openings OE 6 1- The is the side on which the rail is attached. 2 - The first letter refers to the attachment location of the gate. 3 - The second letter refers to the location of the strike plate. 4 - If present, the third letter R denote a recessed gate. Opposite Openings R R Example: R R First Gate - R - gate attachment - strike plate R - recessed gate Second Gate - R - gate attachment - strike plate R - recessed gate P-RYE ELEVTOR PLNNING GUIE PMQ0500.6

85 Hoistway Layout - Paca-Ryde Use specified rail backing from architect to frame into wall. Hoistways below show finished dimensions. Finished hoistway dimensions include drywall, plaster and paint. maximum of 3 (see g below) are allowed between the closed hoistway door and the outer edge of the landing sill. etermine height of hall station by local code. Rough frame door in place with an extra inch of space on each side of the door to allow for door installation. The following examples are of a 1,000 lb. unit. Elevators are illustrated with accordion gates. These symbols are listed beside the car size Waupaca Elevator believes to be best suited for use by wheelchair passengers and their accompanying attendant. Recommended size for wheelchair passenger Recommended size for both wheelchair and attendant passengers R LEFT SME SIE OPENING OE 1 b c d R LEFT SME SIE OPENING OE 1 b c d e f g h i a e f g h i a ELEVTOR HOISTWY LYOUT OE 1 LEFT SME SIE OPENING OE 1 LEFT SME SIE OPENING R SIZE P RYE ELEVTOR HOISTWY IMENSIONS FINISHE HOISTWY IMENSIONS a b c d e f g h i R 48" x 36" 52.25" 54.5" 27.25" 27.5" 10.75" 36" 3" 48" 36" R 54" x 40" R 60" x 36" R 48" x 36" R R 54" x 40" 60" x 36" 56.25" 60.5" 30.25" 27.5" 14.75" 36" 3" 54" 40" 52.25" 66.5" 33.25" 27.5" 10.75" 36" 3" 60" 36" 53.25" 54.5" 27.25" 27.5" 10.75" 36" 3" 48" 36" 55.75" 60.5" 30.25" 27.5" 10.75" 36" 3" 54" 40" 53.25" 66.5" 33.25" 27.5" 10.75" 36" 3" 60" 36" P-RYE ELEVTOR PLNNING GUIE PMQ0500.7

86 Hoistway Layout - Paca-Ryde R LEFT SME SIE OPENING OE 2 b d c R LEFT SME SIE OPENING OE 2 b c d a i h g e f a i h g e f ELEVTOR HOISTWY LYOUT OE 2 RIGHT SME SIE OPENING R R R R SIZE OE 2 R 48" x 36" RIGHT SME R 54" x 40" SIE OPENING R 60" x 36" P RYE ELEVTOR HOISTWY IMENSIONS FINISHE HOISTWY IMENSIONS a b c d e f g h i 52.25" 54.5" 27.25" 27.5" 10.75" 36" 3" 48" 36" 48" x 36" 53.25" 54.5" 27.25" 27.5" 10.75" 36" 3" 48" 36" 54" x 40" 60" x 36" 56.25" 60.5" 30.25" 27.5" 14.75" 36" 3" 54" 40" 52.25" 66.5" 33.25" 27.5" 10.75" 36" 3" 60" 36" 55.75" 60.5" 30.25" 27.5" 10.75" 36" 3" 54" 40" 53.25" 66.5" 33.25" 27.5" 10.75" 36" 3" 60" 36" LEFT FRONT OPENING RIGHT FRONT OPENING OE 3 OE 3 c b d b c d a g h i i h g a f e e f ELEVTOR HOISTWY LYOUT OE 3 LEFT FRONT OPENING R SIZE 48" x 36" P RYE ELEVTOR HOISTWY IMENSIONS 54" x 40" 60" x 36" FINISHE HOISTWY IMENSIONS a b c d e f g h i 50.25" 56.5" 29" 27.5" 15" 36" 3" 48" 36" 54.25" 62.5" 32.5" 27.5" 21" 36" 3" 54" 40" 50.25" 68.5" 35.5" 27.5" 27" 36" 3" 60" 36" OE 3 48" x 36" 50.25" 56.5" 29" 27.5" 15" 36" 3" 48" 36" RIGHT FRONT OPENING 54" x 40" 60" x 36" 54.25" 62.5" 32" 27.5" 21" 36" 3" 54" 40" 50.25" 68.5" 35" 27.5" 27" 36" 3" 60" 36" P-RYE ELEVTOR PLNNING GUIE PMQ0500.8

87 Hoistway Layout - Paca-Ryde a R - R b d h i R - R OPPOSITE OPENING OPPOSITE OPENING OE 4 OE 4 b c d e f a i g h c g e f ELEVTOR HOISTWY LYOUT OE 4 OPPOSITE OPENING OE 4 a b c d e f g h i R-R 48" x 36" 52.25" 55" 27.5" 27.5" 10.75" 36" 3" 48" 36" R-R R-R R-R R SIZE P RYE ELEVTOR HOISTWY IMENSIONS 54" x 40" 60" x 36" FINISHE HOISTWY IMENSIONS 56.25" 61" 30.5" 27.5" 14.75" 36" 3" 54" 40" 52.25" 67" 33.5" 27.5" 10.75" 36" 3" 60" 36" 48" x 36" 53.25" 55" 27.5" 27.5" 10.75" 36" 3" 48" 36" OPPOSITE OPENING R-R R-R 54" x 40" 60" x 36" 55.75" 61" 30.5" 27.5" 10.75" 36" 3" 54" 40" 53.25" 67" 33.5" 27.5" 10.75" 36" 3" 60" 36" b R RIGHT JENT 90 OPENINGS OE 5 c d R- LEFT JENT 90 OPENINGS OE 6 c d b a i h g e f e f g h i a ELEVTOR HOISTWY LYOUT OE 5 RIGHT JENT 90 OPENING OE 6 LEFT JENT 90 OPENING R- R- R- R- R- R- k R SIZE j P RYE ELEVTOR HOISTWY IMENSIONS 48" x 36" 50.25" 57" 27.25" 27.5" 10.5" 32" 3" 48" 36" 15.5" 54" x 40" 60" x 36" 48" x 36" 50.25" 57" 27.25" 27.5" 10.5" 32" 3" 48" 36" 15.5" 54" x 40" 60" x 36" j a b c d e f g h i j k k FINISHE HOISTWY IMENSIONS 54.25" 63" 30.25" 27.5" 10.5" 36" 3" 54" 40" 21.5" 36" 50.25" 69" 33.25" 27.5" 10.5" 32" 3" 60" 36" 27.5" 36" 36" 36" 54.25" 63" 30.25" 27.5" 10.5" 36" 3" 54" 40" 21.5" 36" 50.25" 69" 33.25" 27.5" 10.5" 32" 3" 60" 36" 27.5" 36" P-RYE ELEVTOR PLNNING GUIE PMQ0500.9

88 Hoistway onstruction - Paca-Ryde The typical layouts shown here may vary from your actual hoistway. The purpose of these layouts are for a general understanding. Please refer to the Waupaca Elevator drawings and specifications that will be provided by the company. OVERHE LERNE HOISTWY OPENING TOP PLTE TRUSS LMINTE VENEER LUMER OTTOM PLTE FLOOR JOIST HEER FLOOR HEIGHT STU HOISTWY OPENING PIT FLOOR ENTER LINE OF RIL WLL 13-3/4" 13-3/4" 37" 18-1/2" 18-1/2" TOTL R TRVEL PIT EXMPLE OF ROUGH FRME HOISTWY WITHOUT RYWLL OORWY (4) 1-3/4" X 9-1/2" LMINTE VENEER LUMER (LVL) EXMPLE OF TYPIL LYOUT These drawings depict sample construction only. It is the responsibility of the installer/contractor or engineer to design and specify structural supports. ll construction to be in compliance with local codes. PIT P-RYE ELEVTOR PLNNING GUIE PMQ

89 Hoistway Specifications - Paca-Ryde Refer to Illustration on previous page TTENTION ONSTRUTION ONTRTOR: This is an example of a hydraulic hoistway. Job specific documentation will be provided by Waupaca Elevator from which to construct the hoistway. Hoistway onstruction Requirements (to be completed prior to elevator installation by contractor) 1. Electrical Requirements: - edicated 208/230 V 30 MP ircuit Single Phase, 60 Hertz. - fused disconnect switch with branch 3 pole circuit wire to suit a 30 MP service, fused for 30 MP dual element (time delay fuse) with neutral Volt, 15 MP single phase circuit for car lighting. - Electrical wiring to comply with applicable codes. 2. Unfinished/Un-installed oor - Installation company may prefer a minimum of one hoistway door and associated framing be left unfinished/un-installed to accommodate elevator installation equipment and to prevent accidental damage to door and framing (preferably at grade level). 3. Plumb and Square Hoistway - Hoistway must be plumb within 1/8 inch per 10 ft. of height and square at any point within 1/4 inch based on difference in diagonal measurements. 4. Supportive Structure - Structure must be capable of supporting the appropriate loads. Local engineering support is recommended. 5. Telephone onnection - ode requires a telephone connection to the elevator car, therefore, a phone line must be installed leading to the controller. 6. SME 17.1 Part Hoistway to be constructed in accordance with SME17.1 Part 5.3 and all local codes. 7. Hoistway oor Security (Interlocks) - ll hoistway doors require interlocks as well as a door handle and a latch set. Interlocks will be installed by the elevator installers. Waupaca Elevator recommends the use of solid core doors. 8. Temperature Requirements - Hoistway and machine room (if applicable) temperature should be maintainable between 60 F- 110 F and should not be exposed to the elements. 9. No lterations - ny alterations to the equipment without written authorization by Waupaca Elevator will void all warranties. 10. Pit Floor Strength - pit floor must be designed to withstand a load of 4,000 lbs. When used, concrete must be a minimum of 4 thick and rated at 3500PSI. P-RYE ELEVTOR PLNNING GUIE PMQ

90 Elevation and Hoistway eiling Heights Waupaca Elevator s Paca Ryde offers a total of five stops and a total travel distance of 50 feet. Minimum Hoistway eiling Heights* Inside ab imension Minimum Hoistway eiling Height * ustom sized cabs will alter these dimensions. Waupaca Elevator will provide you with the appropriate dimensions. Elevation Rail Layout and Jack alculations Minimum Hoistway eiling Height 31" ENTERLINE OF FSTENERS RIL LENGTH PISTON PROJETION Top Floor dditional Floors RIL FSTENERS SUPPLIE Y ONTRTOR 1-1/4" 9/16" 2" JK RKET YLINER LENGTH Inside ab imension Total Travel PEESTL RKET PEESTL First Floor Pit epth Recommended 8" Minimum 6" Rail alculations Rail Length = Pit epth + Travel + ar I.. Height + 10 P-RYE ELEVTOR PLNNING GUIE PMQ

91 ontroller Space - Paca-Ryde Typical Layout 12" MINIMUM OVERHE 1. The ontroller requires minimum clear space of 36 x 30 located directly in front of the controller (refer to illustration). 7' STNR R HEIGHT 2. lockable service disconnect must be placed within sight of the controller and must be easily accessible, from the latch side of the doorway (if door is present). 3. ontroller Space must be provided for the operating equipment that meets national electrical code clear space requirements and all local codes. Must provide a convenience outlet and light with switch. Temperatures must be maintained between F (with a relative humidity not to exceed 95%). 50' MXIMUM TRVEL LENGTH 14" MINIMUM TRVEL ETWEEN FLOORS ONTROLLER - NORMLLY SURFE MOUNTE 33" 6" MINIMUM PIT EPTH 8" REOMMENE PIT EPTH 14 1/2" 30 3/4" 36" 30" ONTROLLER SIZE STNR 24" x 18" x 8" UILOUT ISONNET NOTE : THE MHINE ROOM MY E PLE ON NY LEVEL OF THE HOME. P-RYE ELEVTOR PLNNING GUIE PMQ

92 Elevator Equipment - Paca-Ryde Typical Pump Unit Valve Stopping evices Interlocks Rails PUMP UNIT HS ONSTNT ISPLEMENT ROTRY SREW PUMP POWERE Y 2 1/2 HORSEPOWER, 230 SINGLE PHSE MOTOR. OIL TNK REQUIRES PPROXIMTELY 30 GLLONS OF W-32 HIGH GRE HYRULI OIL. WHEN LOTING MHINE ROOM UP TO 40 FT OF HOSE N E USE. VLVE TWO SPEES FOR SMOOTH STRTS N STOPS. WORKING PRESSURE IS 525 PSI T 5.5 GPM. 300 LS. MX. TENSION PER FSTENER RIL 300 LS. MX. TENSION PER FSTENER EMI - III INTERLOK STOPPING EVIES MGNETI TPE REER FOR LEVELING URY & TOP FINL LIMIT SWITHES. HOISTWY OOR INTERLOKS EMI Required at each opening to prevent hoistway or elevator access while elevator is operating or at another landing. P-RYE ELEVTOR PLNNING GUIE PMQ

93 Paca-Ryde Elevator Series 016 FINL LIMIT M RIL RMS HEER HYRULI JK WIRE ROPE SLING SHKLES SLING EXTENSIONS ONTROLLER ISONNET GTE OPERTOR FINL LIMITS R TOP OX LIGHTS EMI INTERLOK HYRULI PUMP R OPERTING PNEL ORIN GTE HLL STTION GTE TRK R P-RYE ELEVTOR PLNNING GUIE PMQ

94 PMQ0500- MRH North allard Road ppleton, WI Phone P-RYE ELEVTOR PLNNING GUIE PMQ

95 USTOM-LIFT PITY Lbs. R SIZE - Maximum of 12 sq. ft. STOPS -up to 6 stops TRVEL -up to 50 ft. SPEE - 30 ft. per minute WINING RUM RESIENTIL ELEVTOR TRUK - heavy gauge steel with hi-density synthetic guides and rollers LE - two 1/4" 8x19 G/S157 ELETRI SUPPLY -230 volts, single phase, 60 hertz. For 208 volts, single phase, a uck oost transformer must be added. separate 120-volt circuit is required for cab lighting Series 010 & 210 PIT EPTH -6" minimum pit required OVERHE -8' 0" above top floor with standard 7' I.. car (additional overhead required with some options) GUIE RIL -3/16" steel channel. MOTOR- single speed, 2HP, instant reversing GEROX -high- ratio, direct mounted and coupled RUM - single drum with outboard bearing RKE - electrically released, spring applied SLK LE/ROKEN ROPE - twin instantaneous, broken cable and slack cable applied by a retained compression spring. ONTROLS - fully automatic at car and landings, car light switch, emergency stop switch, in-use indicator at landings SIGNL SYSTEM - wall mount phone jack, emergency alarm HOISTWY OOR INTERLOKS - required at each landing MHINE LOTION - multiple remote locations EMERGENY LOWERING - manual hand wheel R - Frameless car with accordion gate standard ITIONL OPTIONS - are available, for details contact your local dealer. ISONNET TO E EFINE Y OE Packy T h e Wau pacader m THE WUP ELEVTOR OMPNY 02/ N. allard Road - ppleton, WI

96 This page intentionally left blank

97 Planning Guide ustom-lift Elevator USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.1

98 USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.2

99 We are a proud member of the ccessibility Equipment Manufacturers ssociation. This symbol assures you of our commitment to high quality and accessibility to everyone. Waupaca Elevator Mission Statement Our company s mission is to supply and service products that meet or exceed our customers expectations of high quality, value, delivery and longevity. Our success is a direct reflection of our employees involvement and commitment to excellence. We strive to continuously improve our products to ensure meeting the future requirements of our customers and facilitate competitive growth. SI 3-Part Specifications ustomize and download SI 3-Part Specifications by logging on to: - specify Waupaca Elevator as the requested manufacturer - go to rchitect Section click on linking icon Spec Wizard is a faster easier way to customize SI 3-part residential elevator specifications. Follow the above website information and choose the Spec Wizard icon. The drop down menus couldn t be any easier to use, just click on your choice of listed options and within a couple of minutes you have a completely customized spec. Table of ontents Introduction... 4 Minimum - Maximum imensions... 6 ar Opening onfigurations... 6 Hoistway Layout Hoistway Illustration Hoistway Specifications Elevation and Hoistway eiling Height Machine Room Elevator Equipment Elevator Series 010 & 210 Illustration USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.3

100 Introduction This Planning Reference Guide is to be used as a guide in deciding the type of elevator to be installed, parameters of installation and steps taken to achieve a proper elevator installation. This guide may be used by the architect, contractor, dealer or home owner. The information in this guide is intended as an overview, each installation will have job specific specifications that must be followed. o not attempt to construct a hoistway on this information alone. Elevator installation is to be done by an authorized elevator contractor, and in accordance with installation instructions provided by the manufacturer. Installation must also be in compliance with requirements of the National Electric ode, merican Society of Mechanical Engineers safety code, and state and local building codes. Waupaca Elevator s products are designed to meet the requirements of SME National Elevator odes for residential elevators and are fully certified by a registered professional engineer. Waupaca Elevator ompany, Inc. elevators manufactured and installed under the proper parameters are warranted for 2 years. Manufacturer assumes no liability for equipment not installed in compliance with these codes. Planning Steps 1. - Locate local dealer and together determine the following: - Select drive system, car type and design specifications - ddress national, state and local code requirements - Hoistway size - ar size, layout and options E - Machine room location and layout (if required) F - Electrical requirements 2. - Obtain and follow site specific field drawings while building hoistway, doorways and any other construction related to the elevator oordinate with dealer to install elevator. USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.4

101 ustom-lift Winding rum Elevator Series 010 (500 lbs.) Series 210 with PL (500 lbs.) dvantages Minimum Required Hoistway Space Economical Reliable The elevators listed in the following section are based upon our standard 12 sq. ft. car. USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.5

102 Hoistway Layout - ustom-lift Minimum and Maximum imensions Finished Hoistway 44-1/2" Minimum 2" 61" Maximum 2" 4-1/2" Finished Hoistway 33" minimum 51" Maximum 4-1/2" NOTE: 24" O.. Min. (42" O.. Max.) Stabilizer racket 40-1/2" O.. Min. (57" O.. Max.) * Single Opening /4 O.. (outside dimension) minimum (rail is not centered in hoistway) 1) Minimum dimensions reflect rail centered in hoistway 2) Minimum dimension for car without a gate recess is 24 O.. (outside dimension) 3) ar I.. (inside dimensions) can not exceed 12 sq. ft. ar Opening onfigurations and oding Left Same Side Opening OE 1 Right Same Side Opening OE 2 Front Opening OE 3 Opposite Openings OE 4 Right djacent 90 Openings OE 5 Left djacent 90 Openings OE 6 1- The is the side on which the rail is mounted. 2 - The first letter refers to the attachment location of the gate. 3 - The second letter refers to the location of the strike plate. 4 - If present, the third letter R denotes a recesssed gate. Opposite Openings R R Example: R R First Gate - R - gate attachment - strike plate R - recessed gate Second Gate - R - gate attachment - strike plate R - recessed gate USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.6

103 Hoistway Layout - ustom-lift Use specified rail backing from architect to frame into wall. The hoistway illustrations below show finished dimensions. Finished hoistway dimensions include drywall, plaster and paint. maximum of 3 (see f below) are allowed between the closed hoistway door and the outer edge of the landing sill. etermine height of hall station by local code. Rough frame door in place with an extra inch of space on each side of the door to allow for door installation. The following examples are of a 500 lb. unit. Elevators are illustrated with accordion gates. R LEFT SME SIE OPENING OE 1 b c R LEFT SME SIE OPENING OE 1 b c d e f g h a d e f g h a ELEVTOR USTOM-LIFT ELEVTOR HOISTWY IMENSIONS HOISTWY FINISHE HOISTWY IMENSIONS LYOUT R SIZE a b c d e f g h OE 1 R 48" x 36" 47" 54.5" 27.25" 5.5" 36" 3" 48" 36" LEFT SME SIE OPENING 54" x 40" 60" x 36" Not vailable Not vailable OE 1 LEFT SME SIE OPENING R 48" x 36" 54" x 40" 60" x 36" 48" 54.5" 27.25" 5.5" 36" 3" 48" 36" Not vailable Not vailable USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.7

104 Hoistway Layout - ustom-lift R RIGHT SME SIE OPENING OE 2 b c R RIGHT SME SIE OPENING OE 2 b c a h g f d e a h g f d e ELEVTOR HOISTWY LYOUT OE 2 RIGHT SME SIE OPENING OE 2 RIGHT SME SIE OPENING R R USTOM-LIFT ELEVTOR HOISTWY IMENSIONS R SIZE 48" x 36" 54" x 40" 60" x 36" 48" x 36" 54" x 40" 60" x 36" FINISHE HOISTWY IMENSIONS a b c d e f g h 47" 54.5" 27.25" 5.5" 36" 3" 48" 36" Not vailable Not vailable 48" 54.5" 27.25" 5.5" 36" 3" 48" 36" Not vailable Not vailable LEFT FRONT OPENING RIGHT FRONT OPENING OE 3 OE 3 b b c c a g h h g a f f d e e d ELEVTOR HOISTWY LYOUT OE 3 LEFT FRONT OPENING USTOM-LIFT ELEVTOR HOISTWY IMENSIONS FINISHE HOISTWY IMENSIONS R SIZE a b c d e f g h 48" x 36" 45" 56.5" 29.5" 5.5" 36" 3" 48" 36" 54" x 40" Not vailable 60" x 36" Not vailable OE 3 48" x 36" 45" 56.5" 29.5" 5.5" 36" 3" 48" 36" RIGHT FRONT OPENING 54" x 40" 60" x 36" Not vailable Not vailable USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.8

105 Hoistway Layout - ustom-lift d e R - R OPPOSITE OPENING OE 4 OE 4 b b c c g a a h h f g f R - R OPPOSITE OPENING d e ELEVTOR HOISTWY LYOUT OE 4 OPPOSITE OPENING OE 4 R-R 48" x 36" R-R USTOM-LIFT ELEVTOR HOISTWY IMENSIONS R SIZE 54" x 40" 60" x 36" 48" x 36" a b c d e f g h 47" 55" 27.50" 5.5" 36" 3" 48" 36" Not vailable Not vailable FINISHE HOISTWY IMENSIONS 48" 55" 27.50" 5.5" 36" 3" 48" 36" OPPOSITE OPENING 54" x 40" 60" x 36" Not vailable Not vailable R RIGHT JENT 90 OPENINGS OE 5 b c R- LEFT JENT 90 OPENINGS OE 6 b c a f g h f e d d e f h g f a j i i j ELEVTOR HOISTWY LYOUT OE 5 RIGHT JENT 90 OPENING OE 6 LEFT JENT 90 OPENING R- R- R SIZE 48" x 36" 54" x 40" 60" x 36" 48" x 36" 54" x 40" 60" x 36" USTOM-LIFT ELEVTOR HOISTWY IMENSIONS FINISHE HOISTWY IMENSIONS a b c d e f g h i j 45" 57" 27.25" 5.25" 32" 3" 48" 36" 15.5" 36" Not vailable Not vailable 45" 57" 27.25" 5.25" 32" 3" 48" 36" 15.5" 36" Not vailable Not vailable USTOM-LIFT ELEVTOR PLNNING GUIE PMQ0100.9

106 Hoistway Illustrations - ustom-lift The typical layouts shown here may vary from your actual hoistway. The purpose of these layouts are for a general understanding. Please refer to the Waupaca Elevator drawings and specifications that will be provided by the company. OVERHE LERNE HOISTWY OPENING TOP PLTE TRUSS LMINTE VENEER LUMER OTTOM PLTE FLOOR JOIST HEER FLOOR HEIGHT STU HOISTWY OPENING PIT FLOOR ENTER LINE Of RIL WLL 14" TOTL R TRVEL PIT LVL TO RUN ENTIRE HEIGHT OF HOISTWY EXMPLE OF ROUGH FRME HOISTWY WITHOUT RYWLL OORWY PIT FINISHE HOISTWY SURFE 14" LMINTE VENEER LUMER (LVL) MINIMUM 3" THIK USE TO NHOR RIL RKETS EXMPLE OF TYPIL LYOUT 10-1/2" /L RIL FSTENERS These drawings depict sample construction only. It is the responsibility of the installer/contractor or engineer to design and specify structural supports. ll construction to be in compliance with local codes. USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

107 Hoistway Specifications - utom-lift Refer to Illustration on previous page TTENTION ONSTRUTION ONTRTOR: This is an example of a winding drum hoistway. Job specific documentation will be provided by Waupaca Elevator from which to construct the hoistway. Hoistway onstruction Requirements (to be completed prior to elevator installation by contractor) 1. Electrical Requirements: - edicated 230 V 30 MP ircuit Single Phase. Fuse should be a time delay 20 MP. - Power supply to be installed in a lockable fused disconnect V 15 mp ircuit Single Phase with manual disconnect & 15 MP fuse. - Electrical wiring to comply with applicable codes. 2. Unfinished/Un-installed oor - Installation company may prefer a minimum of one hoistway door and associated framing be left unfinished/un-installed to accommodate elevator installation equipment and to prevent accidental damage to door and framing (preferably at grade level). 3. Plumb and Square Hoistway - Hoistway must be plumb within 1/8 inch per 10 ft. of height and square at any point within 1/4 inch based on difference in diagonal measurements. 4. Supportive Structure - Structure must be capable of supporting the appropriate loads. Local engineering support is recommended. 5. Machine Room - If machine room space is provided, it must meet National Electrical ode clear space requirements and all local codes. Machine room space must have a light switch and a convenience outlet at code specified location. n opening between machine room space and hoistway must be provided in specified location for sheave & wire rope arrangement. 6. Telephone onnection - ode requires a telephone connection to the elevator car therefore, a phone line must be installed in the machine room (near controller). 7. SME 17.1 Part Hoistway to be constructed in accordance with SME17.1 Part 5.3 and all local codes. 8. Hoistway oor Security (Interlocks) - ll hoistway doors require interlocks as well as a door handle and a latch set. Interlocks will be installed by the elevator installers. Waupaca Elevator recommends the use of solid core doors. 9. Temperature Requirements - Hoistway and machine room (if applicable) temperature should be maintainable between 60 F- 110 F and should not be exposed to the elements. 10. No lterations - ny alterations to the equipment without written authorization by Waupaca Elevator will void all warranties. 11. Pit Floor Strength - pit floor must be designed to withstand an impact of 1050 lbs. per sq. ft. When used, concrete must be a minimum of 4 thick rated at 3500PSI. USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

108 Hoistway eiling Heights and Elevation - ustom Lift Inside ab imension Minimum Hoistway eiling Heights* Series Inside ab imension Series Minimum Minimum * ustom sized cabs will alter these dimensions. Waupaca Elevator will provide you with the appropriate dimensions. MINIMUM HOISTWY EILING HEIGHT dditional space may be required for hoisting and maneuvering equipment into place with overhead mounted units. Waupaca Elevator s ustom-lift offers a total of six stops and a total travel distance of 50 feet. RIL LENGTH TOP FLOOR Pit epth ll other layouts require a minimum of 6 but 8 is recommended. TOTL TRVEL INSIE IMENSIONS FIRST FLOOR PIT EPTH 6" MINIMUM USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

109 Machine Room - ustom-lift Series 010 & 210 (500 lbs.) Typical Machine Room Layout (with traveling sheave and machine room behind rail) additional layouts can be found on the rchitect s inder or contact Waupaca Elevator for drawings. 1. Fleet angle distance and drum size will change per job (refer to table below). ONTROLLER 2. oncrete floor must be a minimum of 4 thick rated at 3500 psi. If a floating slab is used, it must be tied to the structure. 3. lockable service disconnect must be placed within sight of the controller and easily accessible from the latch side of the doorway. 4" MIN OF ONRETE OR 3500 PSI 4. The temperature should be maintainable between 60 F F and should not be exposed to the elements. MHINE SPE HOISTWY /L RIL /L RUM 16" MIN. MHINE SPE 12.69" /L OF RIL TYPIL TRVELING SHEVE RRNGEMENT TRVEL <14' <24' <32' <40' <50' RUM LENGTH 8" 12" 15" 18" 22" RUM /L IST. "" 8.25" 10" 12.25" 14.5" 14.5 MH. SE "E" 22" 26" 29" 34" 34" MINIMUM FOR "" 30" 30" 30" 43" 72" LLOW 26" FOR MOTOR LERNE MHINE SPE HT. "E" 2 "" "E".56" 13.5" 17" 6.75" USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

110 Elevator Equipment - ustom-lift Series 010 & 210 (500 lbs.) Typical Powerhead Interlocks Main Rail Motor Gear ox rum Sheaves FLOOR MOUNT POWERHE 2000 LS 250 LS MOTOR lbs. I or III PHSE, 2 HORSEPOWER INSTNT REVERSING. GER OX - HIGH RTIO, IRET MOUNTE N OUPLE. EMI - III INTERLOK GL TYPE "N" INTERLOK HOISTWY OOR INTERLOKS EMI or GL TYPE "N" required at each opening to prevent hoistway or elevator access while elevator is operating or at another landing. RUM - SINGLE RUM WITH OUTOR ERING FOR SUPPORT. NOTE: THE SHEVES & RRNGEMENT WILL E ETERMINE Y LOTION OF THE MHINE ROOM. MIN RIL - 3/16" thick x 8" wide precision formed steel channel with mounting bracket supports at 30" intervals. Heavy-duty splice bolts are used at all matched, ground, and numbered rail splices for installation LS TRVELING FLOOR SHEVE TOP VIEW OF RIL TRVELING PIT SHEVE 300 LS MX SHER PER FSTENER MIN RIL USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

111 ustom-lift Elevator Series 010 & 210 (500 lbs.) TOP SHEVE WIRE ROPES ISONNET ONTROLLER MIN RIL POWERHE SLING UXILIRY GUIE RKET & ROLLERS R USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

112 PMQ0100- MRH North allard Road ppleton, WI Phone USTOM-LIFT ELEVTOR PLNNING GUIE PMQ

113 EXELEVTOR PITY -950Lbs. ROPE HYRULI RESIENTIL ELEVTOR Series 014 R SIZE - Maximum of 15 sq. ft. TRVEL - up to 50 ft. STOPS - up to 6 stops SPEE - 40 feet per minute PIT EPTH - 8" minimum pit require OVERHE - 8'-0" above top floor with standard 7'-0" I.. car (additional overhead required with some options). GUIE RIL - 8# elevator T -rail. PUMP UNIT - rotary screw type with submersed motor. MOTOR - single speed, 2HP. VLVE - 2 speed. ONTROLS -fully automatic at car and landings, car light switch, emergency stop switch; emergency alarm button, in-use indicator at landings and auto light. Electronic controller is microprocessor based SIGNL SYSTEM -wall-mount phone jack, emergency alarm HOISTWY OOR INTERLOKS -required at each landing EMERGENY LOWERING -automatic descent with back-up power supply R - Frameless car with accordion gate standard ITIONL OPTIONS - are available, for details contact your local dealer. SLK LE/ROKEN ROPE - twin instantaneous, broken and slack cable applied by retained compression spring LE -two 3/8" 8x19 traction steel cables ELETRI SUPPLY -208/ 230 volts, single phase, 60 hertz with 3 pole disconnect switch, a separate 120-volt circuit is required for car lighting Packy T h e Wau pacader m 05/08 THE WUP ELEVTOR OMPNY 1726 N. allard Road - ppleton, WI

114 This page intentionally left blank

115 Planning Guide Excelevator Elevators EXELEVTOR ELEVTOR PLNNING GUIE PMQ0200.1

116 EXELEVTOR ELEVTOR PLNNING GUIE PMQ0200.2

117 We are a proud member of the ccessibility Equipment Manufacturers ssociation. This symbol assures you of our commitment to high quality and accessibility to everyone. Waupaca Elevator Mission Statement Our company s mission is to supply and service products that meet or exceed our customers expectations of high quality, value, delivery and longevity. Our success is a direct reflection of our employees involvement and commitment to excellence. We strive to continuously improve our products to ensure meeting the future requirements of our customers and facilitate competitive growth. SI 3-Part Specifications ustomize and download SI 3-Part Specifications by logging on to: - specify Waupaca Elevator as the requested manufacturer - go to rchitect Section click on linking icon SpecWizard is a faster easier way to customize SI 3-part residential elevator specifications. Follow the above website information and choose the Spec Wizard icon. The drop down menus couldn t be any easier to use, just click on your choice of listed options and within a couple of minutes you have a completely customized spec. Table of ontents Introduction... 4 Minimum - Maximum imensions... 6 ar Opening onfigurations... 6 Hoistway Layout Hoistway Illustration Hoistway Specifications Elevation and Hoistway eiling Height Rail Layout and Jack alculation ontroller/electrical Space Elevator Equipment Elevator Series 014 Illustration EXELEVTOR ELEVTOR PLNNING GUIE PMQ0200.3

Residential Elevators

Residential Elevators Residential Elevators Waupaca Elevator Since 1957, Waupaca Elevator has built safety, on roped hydraulic units, and first use of performance quality, value, and choice into the manufacture of enhancing

More information

Planning Guide. Residential Winding Drum Elevators. Series MRL RMR. Built on T Rail

Planning Guide. Residential Winding Drum Elevators. Series MRL RMR. Built on T Rail Planning Guide Residential Winding rum Elevators uilt on T Rail Series 021 - MRL 022 - RMR We are a proud member of the ccessibility Equipment Manufacturers ssociation. This symbol assures you of our

More information

ELVORON HR DESIGN AND PLANNING GUIDE

ELVORON HR DESIGN AND PLANNING GUIDE ELVORON HR DESIGN AND PLANNING GUIDE Hydraulic Home Elevator Quality Elevators by Garaventa www.garaventaelevator.com Table of Contents Elvoron HR - Hydraulic Residential Elevator... 2 Technical Reference:...

More information

Residential Elevator DESIGN GUIDE. ASME A17.1, Section 5.3. Inline Gear Drive Hydraulic Drive Winding Drum Drive. symmetryelevator.com

Residential Elevator DESIGN GUIDE. ASME A17.1, Section 5.3. Inline Gear Drive Hydraulic Drive Winding Drum Drive. symmetryelevator.com Residential Elevator ESIGN GUIE SME 7., Section 5.3 Inline Gear rive Hydraulic rive Winding rum rive symmetryelevator.com 877.375.428 Table of ontents bout Symmetry Elevating Solutions... 2 Residential

More information

Home Elevator. Specifically engineered for residential applications

Home Elevator. Specifically engineered for residential applications Home Elevator Specifically engineered for residential applications HOME ELEVATOR Why a residential elevator? 2 4 3 1 Simplify Daily Routines 1 Reduce heavy lifting when transporting storage, laundry or

More information

Elite RESIDENTIAL ELEVATOR. AmeriGlide Accessibility Solutions

Elite RESIDENTIAL ELEVATOR. AmeriGlide Accessibility Solutions Elite RESIDENTIAL ELEVATOR Accessibility Solutions We believe in providing a residential elevator that exceeds all industry standards in safety, performance and reliability. Our residential elevator package

More information

Elvoron CPL. Planning Guide

Elvoron CPL. Planning Guide Elvoron PL Planning Guide Please note: Dimensions provided in this Guide are for reference only and should not be used for site preparation or construction. 2 Table of ontents Elvoron PL... 4 omponent

More information

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator

Quality Elevators by Garaventa ELVORON HR. Hydraulic Residential Elevator Quality Elevators by Garaventa ELVORON HR Hydraulic Residential Elevator The Elvoron HR - Hydraulic Residential Elevator Once considered a luxury, residential elevators are now in common use in both newly

More information

Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer)

Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer) Residential Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Concord Dealer) Savaria Concord Lifts Inc. Part # 000626 (Rev. 24-m01-2008) IMPORTANT Ensure that only

More information

Built for every day, designed for any style.

Built for every day, designed for any style. Home Elevators Built for every day, designed for any style. Garaventa Lift has been moving people since 1928. Our products have always stood the test of time. We began by building tramways in the Swiss

More information

Manufacturer, Installation & Service Of Residential Elevators

Manufacturer, Installation & Service Of Residential Elevators Manufacturer, Installation & Service Of Residential Elevators Serving Nationwide 2210 ALLEN DRIVE, SALISBURY, MD 21801 Toll Free 800-787-0436 Phone: 410-749-3489 Fax 410-341-7505 www.delawareelevator.com

More information

Home Elevator. Planning Guide

Home Elevator. Planning Guide Home Elevator Planning Guide Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation or construction. 2 Table of Contents Elvoron Home Elevator...4

More information

Built for every day, designed for any style.

Built for every day, designed for any style. Home Elevators Built for every day, designed for any style. Garaventa Lift has been moving people since 1928. Our products have always stood the test of time. We began by building tramways in the Swiss

More information

Eclipse Gearless Residential Elevators OWNER S MANUAL

Eclipse Gearless Residential Elevators OWNER S MANUAL Eclipse Gearless Residential Elevators OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000846 22-m09-2011 2 IMPORTANT Ensure that only an Authorized Savaria

More information

savaria, Eclipse Residential Elevator OWNER'S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer)

savaria, Eclipse Residential Elevator OWNER'S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) savaria, Eclipse Residential Elevator OWNER'S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Ea JONATHAN'S sen II Sonsuol 9 Handuotiod Solutions to You( Actsssibi ond

More information

ELVORON HOME ELEVATOR

ELVORON HOME ELEVATOR Creating An Accessible World ELVORON HOME ELEVATOR PLANNING GUIDE www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation

More information

Built for every day, designed for any style.

Built for every day, designed for any style. Home Elevators Built for every day, designed for any style. Garaventa Lift has been moving people since 1928. Our products have always stood the test of time. We began by building tramways in the Swiss

More information

Elvoron Home Elevator

Elvoron Home Elevator Creating An Accessible World Elvoron Home Elevator Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site

More information

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT) Doc: ET 25(6345) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as an AMENDMENT) DRAFT AMENDMENT NO. 3 TO IS 14665 (Part 2 / Sec 1) : 2000

More information

Planning Guide. ThyssenKrupp. ThyssenKrupp Access Residential Elevator Division. for Residential Elevators ASME A17.1, Part V, Section 5.

Planning Guide. ThyssenKrupp. ThyssenKrupp Access Residential Elevator Division. for Residential Elevators ASME A17.1, Part V, Section 5. Planning Guide for Residential Elevators ASME A17.1, Part V, Section 5.3 August 1, 2008 ThyssenKrupp Access Residential Elevator Division ThyssenKrupp Introduction This Planning Guide is designed to assist

More information

A LUXURY STANDARD CREATING A LIFETIME HOME

A LUXURY STANDARD CREATING A LIFETIME HOME A LUXURY STANDARD The Savaria Eclipse home elevator delivers luxury and convenience, with less space needed than traditional elevator designs. Requiring no machine room and minimal overhead drive space,

More information

SunCoast Elevator Co. Residential elevators can be as unique as your home s interior Ph PAGE 2

SunCoast Elevator Co. Residential elevators can be as unique as your home s interior Ph PAGE 2 SunCoast Elevator Co www.suncoastelevator.com - 888 229 0940 Ph Residential elevators can be as unique as your home s interior. PAGE 2 Residential elevators provide convenience for people who shouldn t

More information

Creating An Accessible World ELVORON CPL.

Creating An Accessible World ELVORON CPL. Creating An Accessible World ELVORON CPL Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation

More information

National Reach. Local Service.

National Reach. Local Service. National Reach. Local Service. Section 144216 VERTICAL WHEELCHAIR LIFTS PART 1 GENERAL 1.01 SECTION INCLUDES: A. UL Unenclosed. B. SL Shaftway. C. EL Enclosed. D. Hybrid (Elevator Style Lift). 1.02 RELATED

More information

luxury & convenience home elevators by

luxury & convenience home elevators by luxury & convenience home elevators by slim luxury Classic at its finest. Your choice of luxury MDF or stainless steel cab, finished with stainless steel fixtures and automatic slim doors on the cab and

More information

Owner s Guide. Dumbwaiter. Series DUMBWAITER OWNER S GUIDE 1

Owner s Guide. Dumbwaiter. Series DUMBWAITER OWNER S GUIDE 1 Owner s Guide Dumbwaiter Series 007 011 DUMBWAITER OWNER S GUIDE 1 DUMBWAITER OWNER S GUIDE 2 Congratulations on your choice of a Waupaca Elevator, Company, Inc., Dumbwaiter (W.E.C.). Your dumbwaiter is

More information

Safety Code for Existing Elevators and Escalators

Safety Code for Existing Elevators and Escalators ASME A17.3-2011 (Revision of ASME A17.3-2008) Safety Code for Existing Elevators and Escalators Includes Requirements for Electric and Hydraulic Elevators and Escalators A N A M E R I C A N N A T I O N

More information

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market 1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter

More information

Planning Guide. ThyssenKrupp. ThyssenKrupp Access. for Residential Elevators ASME A Section 5.3. March 28, 2006

Planning Guide. ThyssenKrupp. ThyssenKrupp Access. for Residential Elevators ASME A Section 5.3. March 28, 2006 Planning Guide for Residential Elevators ASME A17.1-2000 Section 5.3 March 28, 2006 Also includes planning information for the new Signet custom elevators! ThyssenKrupp Access Residential Elevator Division

More information

RESIDENTIAL ELEVATORS

RESIDENTIAL ELEVATORS Premier Manufacturer of Custom Residential Elevators RESIDENTIAL ELEVATORS It s About Lifestyle Whether you ve decided to build your dream home or enjoy the freedom to access all levels of your present

More information

INCLINATOR ELEVETTE HOME ELEVATORS INDOOR & OUTDOOR VERTICAL PLATFORM LIFTS RESIDENTIAL & COMMERCIAL DUMBWAITERS

INCLINATOR ELEVETTE HOME ELEVATORS INDOOR & OUTDOOR VERTICAL PLATFORM LIFTS RESIDENTIAL & COMMERCIAL DUMBWAITERS INCLINATOR ELEVETTE HOME ELEVATORS INDOOR & OUTDOOR VERTICAL PLATFORM LIFTS RESIDENTIAL & COMMERCIAL DUMBWAITERS Elevette Home Elevators From simple accessibility to distinctive elegance. Homeowners appreciate

More information

Installation Information 2009 Model 300 Dumbwaiter

Installation Information 2009 Model 300 Dumbwaiter Installation Information 2009 Model 300 Dumbwaiter 3/17/09 Introduction This new model of Matot Dumbwaiter has several features that we hope you find are beneficial. Precision extruded rail sections provide

More information

Bruno VPL-3300B Series

Bruno VPL-3300B Series Bruno VPL-3300B Series 3-Gate Application - Design and Planning Guide www.bruno.com Bruno VPL-3300B Series 3-Gate Application Design and Planning Guide Bruno VPL-3300B Series 3-Gate Application Table of

More information

Innovation in Mobility. R1208 Six-Way Power Seat Base. Operator Manual. 03/25/02 32DSB01.A RICON CORPORATION All Rights Reserved

Innovation in Mobility. R1208 Six-Way Power Seat Base. Operator Manual. 03/25/02 32DSB01.A RICON CORPORATION All Rights Reserved Innovation in Mobility R1208 Six-Way Power Seat Base Operator Manual 03/25/02 32DSB01.A 92-2002 RICON CORPORATION All Rights Reserved Printed in the United States of America This RICON product must be

More information

Infinity & Infinity HD

Infinity & Infinity HD Infinity & Infinity HD Residential Elevators OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000784 10-m01-2011 2 IMPORTANT Ensure that only an Authorized

More information

Infinity & Infinity HD

Infinity & Infinity HD Infinity & Infinity HD Residential Elevators (with Micro-6 Controller) OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000842 30-m06-2017 2 IMPORTANT Ensure

More information

Orion LU/LA Commercial Elevator OWNER S MANUAL

Orion LU/LA Commercial Elevator OWNER S MANUAL Orion LU/LA Commercial Elevator OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000586 16-m08-2012 2 IMPORTANT Ensure that only an authorized Savaria Dealer

More information

Construction, Inspection and Maintenance of: Elevators, Dumbwaiters, Escalators, Moving Walks, Personnel and Material Hoists, Vertical Reciprocating

Construction, Inspection and Maintenance of: Elevators, Dumbwaiters, Escalators, Moving Walks, Personnel and Material Hoists, Vertical Reciprocating STATE OF RHODE ISLAND ELEVATOR SAFETY CODE ORIGINALLY PROMULGATED AND EFFECTIVE OCTOBER 12, 1947 SAFETY CODE RELATING TO: Construction, Inspection and Maintenance of: Elevators, Dumbwaiters, Escalators,

More information

MAINTENANCE EVALUATION CHECKLIST ELECTRIC ELEVATORS

MAINTENANCE EVALUATION CHECKLIST ELECTRIC ELEVATORS Manufacturer: Model: Evaluation Performed By: INTRODUCTION: This checklist will enable the user to make an objective appraisal of the condition of the equipment. Given the variety and complexity of the

More information

INCLINATOR ELEVETTE MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM. Planning Guide. MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM 1000 lb.

INCLINATOR ELEVETTE MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM. Planning Guide. MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM 1000 lb. INCLINATOR ELEVETTE MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM Planning Guide MACHINE ROOMLESS (MRL) OVERHEAD CABLE DRUM 1000 lb. (453 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR PN 67210662 Rev F This page

More information

Bruno VPL-3300B Series

Bruno VPL-3300B Series Bruno VPL-3300B Series Unenclosed Application - Design and Planning Guide MADE IN USA www.bruno.com Bruno VPL-3300B Series Unenclosed Application Design and Planning Guide Bruno VPL-3300B Series Unenclosed

More information

Guide for Inspection of Elevators, Escalators, and Moving Walks

Guide for Inspection of Elevators, Escalators, and Moving Walks ASME A17.2-2014 (Revision of ASME A17.2-2012) Guide for Inspection of Elevators, Escalators, and Moving Walks Includes Inspection Procedures for Electric Traction and Winding Drum Elevators, Hydraulic

More information

American Crescent Elevator's Lula Lift

American Crescent Elevator's Lula Lift 's Lula Lift American Crescent Elevator Mfg., Corp. 310 Stephens Street Picayune, Ms. 39466 Phone (800) 748-9711 or Fax (601) 798-9392 Introduction Congratulations... we welcome you as a new American Crescent

More information

VPL REFERENCE GUIDE & OPTION LIST

VPL REFERENCE GUIDE & OPTION LIST VPL REFERENCE GUIDE & OPTION LIST Bruno Residential Vertical Platform Lift System EFFECTIVE 2014-01-01 (262)567-4990 (866)882-4990 For order convenience please email: sales.orders@bruno.com or Fax to 1-800-676-0665

More information

Trimline Car and Sling

Trimline Car and Sling Trimline Car and Sling Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

VPL REFERENCE GUIDE & OPTION LIST

VPL REFERENCE GUIDE & OPTION LIST VPL REFERENCE GUIDE & OPTION LIST Bruno Residential Vertical Platform Lift System EFFECTIVE May 1, 2013 LIMITED WARRANTY: VERTICAL PLATFORM LIFT Any product sold by BRUNO Independent Living Aids, Inc.,

More information

V1504 Vertical Platform Lift OWNER S MANUAL

V1504 Vertical Platform Lift OWNER S MANUAL V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 30-m06-2017 2 IMPORTANT Ensure that only an authorized Savaria Dealer

More information

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER

INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER INSTALLATION INSTRUCTIONS AMBASSADOR DRUM OVERHEAD SERIES 100 DUMBWAITER The installation of Matot Drum Dumbwaiters should only be performed by qualified, experienced, and trained elevator installers.

More information

Guide for Inspection of Elevators, Escalators, and Moving Walks

Guide for Inspection of Elevators, Escalators, and Moving Walks ASME A17.2-2010 (Revision of ASME A17.2-2007) Guide for Inspection of Elevators, Escalators, and Moving Walks Includes Inspection Procedures for Electric Traction and Winding Drum Elevators, Hydraulic

More information

Health & Safety Policy and Procedures Manual SECTION 22 CRANE SUSPENDED PERSONNEL PLATFORMS

Health & Safety Policy and Procedures Manual SECTION 22 CRANE SUSPENDED PERSONNEL PLATFORMS SECTION 22 CRANE SUSPENDED PERSONNEL PLATFORMS 1. Scope: This policy and procedure applies to the design, construction testing, use, and maintenance or personnel platforms and hosting of personnel platforms

More information

Prolift SCL/Prolift HD

Prolift SCL/Prolift HD Prolift SCL/Prolift HD Accessibility Lifts OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000782 30-m06-2017 2 IMPORTANT Ensure that only an Authorized

More information

DRIVE: 1 hp motor; 1750 rpm, single phase, 120 VAC, 60 Hz, 13.4 Full Load Amps, 1.15 service factor, continuous duty

DRIVE: 1 hp motor; 1750 rpm, single phase, 120 VAC, 60 Hz, 13.4 Full Load Amps, 1.15 service factor, continuous duty Residential Vertical Platform Lift Technical Specifications rev: 4/02/2008 ISO No. 404.96 MODEL NUMBER: Series, Model VPL-3153 & VPL-3175 U.S. F.D.A. CLASSIFICATION: Class II CLASSIFICATION NUMBER: 890.3930

More information

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1 Linear Actuator Installation Manual warranty installation parts list January 2004 Linear Actuator Installation Manual Page 1 MA1221B12 Warranty Information Chore-Time Equipment ( Chore-Time ) warrants

More information

Owner s Manual and Warranty Information

Owner s Manual and Warranty Information RAVE STAIR LIFT Owner s Manual and Warranty Information IMPORTANT! YOU MUST READ AND UNDERSTAND THIS ENTIRE MANUAL BE READ AND UNDERSTOOD BEFORE ATTEMPTING TO OPERATE THIS LIFT. IF THERE IS ANYTHING IN

More information

ARTICLE SAFETY CODES FOR ELEVATORS, ESCALATORS, MANLIFTS AND HOISTS. Elevator Safety

ARTICLE SAFETY CODES FOR ELEVATORS, ESCALATORS, MANLIFTS AND HOISTS. Elevator Safety ARTICLE 21. 3 SAFETY CODES FOR ELEVATORS, ESCALATORS, MANLIFTS AND HOISTS Elevator Safety (The following Indiana Amendments are reprinted here from the Indiana government web site for your convenience.

More information

Major Code changes MESA Continuing Education

Major Code changes MESA Continuing Education Presented By: Bruce Horne - phone: (860) 676-5335 Major Code changes 2004-2013 MESA Continuing Education April 24, 2018 1 Color Code Blue is revised code language/sections Red is code additions 2 ASME

More information

Green Elevator: minimal energy consumption required during ascent and no energy necessary for descent

Green Elevator: minimal energy consumption required during ascent and no energy necessary for descent About PVE Pneumatic Vacuum Elevators, LLC is the designer and manufacturer of the vacuum elevator. PVE is an innovative, technology-based company that has revolutionized how people and goods may be vertically

More information

Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information

Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information IMPORTANT: Read and understand this entire Owner s Manual before attempting to operate this Stair Lift. If you do not

More information

OPERATIONS MANUAL LEVER CHAIN HOIST

OPERATIONS MANUAL LEVER CHAIN HOIST OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions

More information

Product Information Responsibilities of Owners Safety Instructions Warning Labels Installation Instructions...

Product Information Responsibilities of Owners Safety Instructions Warning Labels Installation Instructions... Table of Contents Product Information... 2 Responsibilities of Owners... 3 Safety Instructions... 4 Warning Labels... 5 Installation Instructions... 6 Electrical Installation... 7 Load Capacity... 8 Daily

More information

Raising Standards in Accessibility

Raising Standards in Accessibility Raising Standards in Accessibility HIGHLanDer VERTICAL PLatform Lifts Comprehensive Line of Vertical Lifts for Levels up to 14 Feet. Harmar is the leading manufacturer of innovative accessibility solutions,

More information

36" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions

36 Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual. Fan and Framing Dimensions 6" Galvanized Direct Drive Hyflo Fan Installation and Operators Instruction Manual Fan and Framing Dimensions Planning the layout of the spacing between Fans is very important. Spacing too close together

More information

MACHINE ROOM-LESS ELEVATOR

MACHINE ROOM-LESS ELEVATOR MACHINE ROOM-LESS ELEVATOR Space-saving Elevator With this Machine Room-less elevator, the space could be saved and utilized effectively, thus maximizing rentable space and reducing construction cost for

More information

HOME LIFT CATALOGUE LIFTS & COMPONENTS

HOME LIFT CATALOGUE LIFTS & COMPONENTS HOM LIFT TLOGU LIFTS & OMPONNTS This GL Home Lifts catalogue aims to give you an insight into the GL ImproLift range. GL ImproLift Plus and ImproLift lassic are environmentally conscious, technologically

More information

Opening Quality Doors Around The World. Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual)

Opening Quality Doors Around The World.  Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual) Opening Quality Doors Around The World www.couriondoors.com Installation Instructions Bi-Parting Freight Doors - Q Style (Power and Manual) Table of Contents For Immediate Help Call 1-800-533-5760 Q Style

More information

LU/LA Elevators. Value: 1 contact hour (0.1 CEU) by Jay Dickens

LU/LA Elevators. Value: 1 contact hour (0.1 CEU) by Jay Dickens CERTIFIED ELEVATOR TECHNICIAN Focus on Accessibility LU/LA Elevators by Jay Dickens Learning Objectives After reading this article, you should have learned: Why LU/LA elevators were developed Typical sites

More information

Inteli-Lift GEN II DUMBWAITER

Inteli-Lift GEN II DUMBWAITER 1 877-345-4387 530-295-4900 www.eilifts.com Inteli-Lift GEN II DUMBWAITER The Easiest Dumbwaiter system on the Market Fully UL Certified Dumbwaiter Systems UL File # SA32120 This manual will cover the

More information

Group One Roped Hydraulic. Elevators. as well as many other applications

Group One Roped Hydraulic. Elevators. as well as many other applications Group One Roped Hydraulic Elevators as well as many other applications EECO Roped Dual Holeless EECO Roped Cantilever Holeless EECO Group One Components Hydraulic Jacks EECO manufactures jack units with

More information

Garaventa Genesis OPAL

Garaventa Genesis OPAL Garaventa Genesis OPAL Vertical Wheelchair Lift Owner s Manual 15102 Revision A Table of Contents TABLE OF CONTENTS Introduction... 1 OPAL Components... 3 Operating Instructions... 5 Platform Controls...

More information

Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information

Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information Residential Platform Lifts RPL400 / RPL600 Owner s Manual and Warranty Information IMPORTANT: Read and understand this entire Owner s Manual before attempting to operate this Stair Lift. If you do not

More information

Derailment Detector Assembly

Derailment Detector Assembly Derailment Detector Assembly Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly

More information

Timber Sectional Doors

Timber Sectional Doors are available in a wide variety of sophisticated panel designs and finishes and provide a warm, cozy and welcoming impression. Typically manufactured from Western Red Cedar, these quality doors can truly

More information

Installation and Parts Manual for SPANCO PF Series Gantry Cranes

Installation and Parts Manual for SPANCO PF Series Gantry Cranes Manual No. 103-0003 REV. 08/14 Installation and Parts Manual for SPANCO PF Series Gantry Cranes ISO 9001 REGISTERED SPANCO, Inc. 2 INSTALLATION AND PARTS MANUAL FOR PF SERIES GANTRIES TABLE OF CONTENTS

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

The RICON S-Series Personal Use Wheelchair Lift provides wheelchair access to personal

The RICON S-Series Personal Use Wheelchair Lift provides wheelchair access to personal I. INTRODUCTION The RICON S-Series Personal Use Wheelchair Lift provides wheelchair access to personal vans. The patented movement provides smooth, safe entry and exit and easily lifts up to 800 pounds

More information

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual

Part Number Mini Linear Lift Assembly Installation & Operator s Instruction Manual Part Number 39644 Mini Linear Lift Assembly Installation & Operator s Instruction Manual April 1999 MV1505C Chore-Time Warranty Mini Linear Lift Assembly Manual Chore-Time Warranty Chore-Time Equipment

More information

ATTENTION. 1. Do not attempt to use the power unit to extend your cylinder. This must be done manually.

ATTENTION. 1. Do not attempt to use the power unit to extend your cylinder. This must be done manually. NSS8XLT Installation Manual ATTENTION By following the instructions in this manual you can save yourself much time, frustration and money. The installation of your lift will take 4-5 hours. Do not rush.

More information

Model 289F. Operator s Manual for Morse Model 289F. MORStak TM Forklift-Mounted Drum Racker. The Specialist In Drum Handling Equipment

Model 289F. Operator s Manual for Morse Model 289F. MORStak TM Forklift-Mounted Drum Racker. The Specialist In Drum Handling Equipment Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3 Operating Instructions....................

More information

Midwest Electric Products. AC Disconnects

Midwest Electric Products. AC Disconnects Midwest Electric Products isconnects Midwest Electric Products pplication Information rticle 440 of the National Electrical ode applies to electric motor-driven air conditioning and refrigerating equipment

More information

The Moscone Center Facility Accessibility Information

The Moscone Center Facility Accessibility Information The Moscone Center Facility Accessibility Information Introduction It is The Moscone Center s intention to provide all reasonable accommodation for persons with disabilities to assist them in attending

More information

ES-125 Inclined Platform Lift OWNER S MANUAL

ES-125 Inclined Platform Lift OWNER S MANUAL ES-125 Inclined Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000703 04-m07-2011 2 IMPORTANT Ensure that only an authorized Savaria Dealer

More information

Raising Standards in Accessibility HIG H L A N D E R VERTIC A L P L A TFORM LIFTS

Raising Standards in Accessibility HIG H L A N D E R VERTIC A L P L A TFORM LIFTS Raising Standards in Accessibility HIG H L A N D E R VERTIC A L P L A TFORM LIFTS COMPREHENSIVE LINE OF V ERTIC A L LIFTS FOR LEVEL S UP TO 14 F EET. Harmar is the leading manufacturer of innovative accessibility

More information

Product Information Responsibilities of Owners Safety Instructions Warning Labels Installation Instructions...

Product Information Responsibilities of Owners Safety Instructions Warning Labels Installation Instructions... Table of Contents Product Information... 2 Responsibilities of Owners... 3 Safety Instructions... 4 Warning Labels... 5 Installation Instructions... 6 Electrical Installation... 7 Load Capacity... 8 Daily

More information

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle

Smooth Silent Precise. The best sensation is not to notice anything. A dream lifestyle A dream home COMFORT Advanced technology and warm, sober lines for a functional day-to-day. The best sensation is not to notice anything. A dream lifestyle Smooth Silent Precise 3 ACCESSIBILITY Enjoy the

More information

About MEI. About Minnesota Elevator, Inc. Customer Focus. Installation Experience

About MEI. About Minnesota Elevator, Inc. Customer Focus. Installation Experience 2008-2009 bout MI bout Minnesota levator, Inc. Since 1971, MI has specialized in the manufacture, installation, modernization, and servicing of various types of elevators. Our manufactured equipment is

More information

GUIDELINES FOR THE USE OF SCISSOR LIFTS (ELEVATING WORK PLATFORMS) AND AERIAL BOOM LIFTS (EXTENSIBLE BOOM PLATFORMS)

GUIDELINES FOR THE USE OF SCISSOR LIFTS (ELEVATING WORK PLATFORMS) AND AERIAL BOOM LIFTS (EXTENSIBLE BOOM PLATFORMS) Building for Tomorrow s Leaders LACCD Program Management 1055 Corporate Center Drive Monterey Park, California 91754 www.build-laccd.org 323.981.7200 tel BuildSafe Safety Bulletin for April 2018 GUIDELINES

More information

Basic steps for installing the AmeriGlide Express Dumbwaiter

Basic steps for installing the AmeriGlide Express Dumbwaiter Basic steps for installing the AmeriGlide Express Dumbwaiter 1. Remove Shroud. 2. Mount lower section of Track and Unit to hoistway wall and Brackets. 3. Remove Shipping Bracket from Top of Car. 4. Install

More information

WARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure

WARNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure R & PowerBounce User s Manual ssembly, Installation, Care, Maintenance, and Use Instructions WRNING Read these materials prior to assembling and using the trampoline and Trampoline Enclosure 1) PowerBounce

More information

Provided by: Operating, Maintenance & Parts Manual

Provided by:   Operating, Maintenance & Parts Manual Provided by: www.hoistsdirect.com TB681.qxd 11/29/2004 3:04 PM Page 1 Operating, Maintenance & Parts Manual TB603 Manually Lever Operated Chain Hoist 1100 POUNDS MAXIMUM CAPACITY (500 kg) Follow all instructions

More information

Assessment of Elevator and Escalator Maintenance & Repair Program Final Elevator Audit Submission Foggy Bottom Station - Escalator C04X03 (Entrance)

Assessment of Elevator and Escalator Maintenance & Repair Program Final Elevator Audit Submission Foggy Bottom Station - Escalator C04X03 (Entrance) Foggy Bottom Station - Escalator C04X03 (Entrance) 217 Foggy Bottom Station - Escalator C04X04 (Platform) Foggy Bottom Station Escalator C04X04 (Platform) Escalator Audit Equipment Description The escalator

More information

TABLE OF CONTENTS. Contractor Notes 2. Specifications for Symmetry 3-4 Residential Elevator. Typical Hoistway Configurations 5-7

TABLE OF CONTENTS. Contractor Notes 2. Specifications for Symmetry 3-4 Residential Elevator. Typical Hoistway Configurations 5-7 TABLE OF CONTENTS Contractor Notes 2 Specifications for Symmetry 3-4 Residential Elevator Typical Hoistway Configurations 5-7 Typical Hoistway Construction 8-9 Typical Machine Room Layouts 10-13 System

More information

Read this entire manual before operation begins.

Read this entire manual before operation begins. Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............

More information

201 Series Portable Drum Rotators Operator s Manual for Morse Portable Drum Rotators

201 Series Portable Drum Rotators Operator s Manual for Morse Portable Drum Rotators Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3 Options.............................

More information

WORKBOOK/PRICE LIST JULy 2011

WORKBOOK/PRICE LIST JULy 2011 Spectr a Tables WORKOOK/PRIE LIST JULy 2011 800-873-3252 falconproducts.com Stationary SP3F SQURE x Veneer Upcharge hrome 30 x 30 51 864 1,201 2,039 100 36 x 36 66 911 1,387 2,255 100 42 x 42 81 996 1,649

More information

Piccolo. Vertical cabin platform lifts

Piccolo. Vertical cabin platform lifts Vertical cabin platform lifts These lifts are an ideal access solution for both public and private buildings. This small, low speed lift is ideal for low-rise, low-usage applications. They have the same

More information

Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes

Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes Manual No. 103-0008 REV. 6/11 Installation and Maintenance Manual for SPANCO A Series Aluminum Gantry Cranes ISO 9001 REGISTERED SPANCO, Inc. 2 TABLE OF CONTENTS Warnings... 3 Installation... 4 Maintenance...

More information

INSTRUCTION MANUAL 22K - Fifth Wheel Hitch

INSTRUCTION MANUAL 22K - Fifth Wheel Hitch You can take it with you. INSTRUCTION MANUAL 22K - Fifth Wheel Hitch Product No. 30033 DEALER/INSTALLER: (1) Provide this Manual to end user. (2) Physically demonstrate hitching and unhitching procedures

More information

AIRSCREEN 8700, 8701, 8702, 8703

AIRSCREEN 8700, 8701, 8702, 8703 IRSCRE 8700, 8701, 8702, 8703 = North merican English PRTS INCLUDED C D E F G H I J K L part description 8700 qty. 8701, 8702, 8703 qty. fairing blade 1 1 C D driveside wing non-driveside wing protective

More information

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES

OPERATING MANUAL. centrifugal fan SAFETY PRACTICES 2237 MARSHALLTOWN BLVD. MARSHALLTOWN, IOWA 50158 PHONE: (641) 753-5601 TOLL FREE: 1-800-383-5601 FAX: (641) 752-9748 WWW.SPREAD-ALLMFG.NET OPERATING MANUAL centrifugal fan SAFETY PRACTICES 1. Have a qualified

More information

2-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series

2-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 2 Operating Instructions....................

More information