Sewage ejection units

Size: px
Start display at page:

Download "Sewage ejection units"

Transcription

1 Sewage ejection units Kompaktboy Operation manual 1

2 Table of contents: Page Declaration of conformity General Introduction Enquiries and orders Technical data Range of application Accessories Safety Marking of the notes contained in the operation manual Personnel development and training Dangers in case of non-observance of the safety notes Safety-conscious way of working Safety notes for the operator/user Safety notes concerning maintenance, inspection, and assembly works Unauthorised modification of the machine and fabrication of spare parts Unauthorised modes of operation Transport and temporary storage Transport Temporary storage/conservation Description General Composition and mode of operation Installation Preparation Assembly Placement Inlet Pressure pipe Ventilation Electrical connection Commissioning Maintenance/repair Inspection- and maintenance intervals Maintenance works Collecting tank Non-return valve Miscellaneous Malfunctions; causes and elimination Warranty Technical modifications Appendix: A Example of installation B Dimensions C Sectional drawing and spare parts list

3 Declaration of conformity We, the ZEHNDER Pumpen GmbH Zwönitzer Straße Grünhain-Beierfeld, herewith declare that the sewage ejection units of the type series Kompaktboy conform to the following relevant regulations: - EC low voltage directive 2006/95/EC - EMC directive 2004/108/EC - Machinery directive 2006/42/EC Applied conform standards, particularly - EN EN EN EN EN Grünhain, 03/04/2010 Matthias Kotte Product devlopment 3

4 1. General 1.1 Introduction This operating manual is valid for the sewage ejection units of the type series Kompaktboy. If the instructions of the operation manual especially the safety instructions - are not observed, or in case of unauthorized modifications of the unit or the installation of non-original spare parts, the guarantee expires automatically. The manufacturer assumes no liability for damages resulting from such behaviour! Such as any other electrical device, this product may fail due to absence of mains voltage or a technical failure. If damage could occur, an emergency power supply, a hand diaphragm pump, a second unit (duplex unit) and/or an off-grid alarm device should be provided according to the application. We as manufacturer are at your disposal for consultation also after the purchase. In case of failures or damages, please contact your retailer. Manufacturer ZEHNDER Pumpen GmbH Zwönitzer Straße Grünhain-Beierfeld Manufactured sizes: Kompaktboy 1.1 W Kompaktboy 1.1 D Kompaktboy 1.5 D Kompaktboy 3.0 D - 2P State of the operation manual: April Enquiries and orders In case of enquiries or orders, address yourself to your specialist retailer. 1.3 Technical data Type Kompaktboy Output power P 1 (kw) Output power P 2 (kw) Voltage U (V) Power reception I max (A) Rotational speed (n /min) 1.1 W D D D-2P Pressure socket DN 100 Inlet 3 x DN 50 2 x DN 100* 1 x DN x DN 50/100 Inlet heights h (mm) * / 428 Type Kompaktboy Condenser C (µf) Gross volume V (l) Required place LxW (mxm) Mass (kg) Discharge flow Q max (m³/h) Discharge height H max (m) Cable length L (m) Running wheel shape 1.1 W x Impeller 1.1 D x Impeller 1.5 D x Impeller 3.0 D-2P x Impeller * = these inlets may not be used in Kompaktboy 3.0 D-2P Minimum diameter of the feed opening for the complete pump station: 600 mm Maximum media temperature: 55 C Materials Tank...PE-LD Running wheel...grp (impeller), Seal carrier...pp Motor shaft...stainless steel Seals...NBR 4

5 1.4 Range of application The sewage ejection units of the type series Kompaktboy are used for the disposal (collection and conveyance) of domestic and industrial wastewater, which accumulates below the backwater level of the canal in basement apartments or one-family houses. Limits of application The pump station is not designed for continuous operation! The conveyance data mentioned on the type plate apply only to periodic duty (S3 25 %). The maximum permitted inlet quantity must always be less than the discharge flow of a pump (see type plate) 1.5 Accessories The sewage ejection units of the type series Kompaktboy are completely delivered with: - Control - Fixing material - Flexible connection for ventilation - Non-return valve (integrated in tank) - Flexible connection for pressure junction 2. Safety: ( from: VDMA sheet ) The operation manual at hand provides basic notes which must be taken into account during assembly, operation and maintenance works. Therefore, before assembly and commissioning, this operation manual must be read by the assembler as well as by the responsible personnel/operator at all costs. It always must be available on site of operation of the machine/unit. The general safety notes listed under the main point safety are not the only notes to be taken into account. Please also observe the specific safety instructions, such as those for private use, listed under other main points. 2.1 Marking of the notes contained in the operation manual The safety notes contained in this operation manual which can cause danger to persons are specifically marked by the following general danger symbol Safety sign according to DIN W 9, The following symbol warns against dangers caused by voltage Safety sign according to DIN W 8. In case of safety notes the non-observance of which can cause danger to the machine and its functioning, the word ATTENTION! is inserted. Notes that are directly attached to the machine, such as. - arrow indicating the direction of rotation - marking of liquid connections must be observed and kept in completely readable condition at all costs. 5

6 2.2 Personnel development and training The personnel responsible for operation, maintenance, inspection and assembly must have the corresponding qualifications for those types of work. Area of responsibility, competence and the surveillance of the personnel must be regulated precisely by the operator. If the personnel do not possess the necessary knowledge, they must be trained and instructed. By order of the operator, the instruction and training, if necessary, can be carried out by the manufacturer/supplier. Furthermore the operator must make sure that the personnel have completely understood the content of the operation manual. 2.3 Dangers in case of non-observance of the safety notes The non-observance of the safety notes can cause dangers to persons as well as to the environment and the machine. If the safety notes are not observed, this can result in the loss of all compensation claims. In detail, non-observance can for instance result in the following damages: - Failure of important functions of the machine/unit - Failure of the prescribed methods for maintenance and repair - Endangerment of persons through electrical, mechanical and chemical influences - Endangerment of the environment through leakage of hazardous substances 2.4 Safety-conscious way of working The safety notes listed in this operation manual, the existent national regulations on accident prevention as well as possible internal working, operating, and safety instructions of the operator must be observed. 2.5 Safety notes for the operator/user - Hot or cold machine components which could cause danger must be secured against contact by the customer. - Protection against contact with moving parts (e.g. coupling) must not be removed while the machine is operating. - Leakages (e.g. of the shaft sealing) of hazardous materials to be conveyed (e.g. explosive, toxic, hot) must be discharged in such a way that no danger arises for persons or the environment. The legal requirements must be observed. - Endangerments through electric power must be eliminated (details concerning this, see e.g. the regulations of the VDE (German Association for Electrical, Electronic and Information Technology) and the local energy suppliers). 2.6 Safety notes concerning maintenance, inspection, and assembly works The operator must make sure that all maintenance, inspection, and assembly works are carried out by authorised, skilled, and qualified personnel which are adequately informed by having thoroughly studied the operation manual. Generally, works on the machine are only to be carried out when the machine is turned off. The procedure of switching off the machine, which is described in the operation manual, must be observed at all costs. Pumps or pump units which convey media that are hazardous to health must be decontaminated. Immediately after completion of the works, all safety and protection devices must be reattached or reactivated. Before restart, the points listed in the chapter commissioning must be taken into consideration. 6

7 2.7 Unauthorised modification of the machine and fabrication of spare parts Retrofitting or modifications of the machine are permitted only after having consulted the manufacturer. Original spare parts and accessories authorised by the manufacturer ensure the safety. The use of other parts can lead to the removal of liability for the resulting damages. 2.8 Unauthorised modes of operation The operational reliability is only guaranteed, if the machine is used as intended according to chapter 1 General. The limit values stated in the data sheet must not be exceeded. 3. Transport and temporary storage 3.1 Transport The sewage ejection units of the type series Kompaktboy must not be thrown or dropped. Furthermore, they should be transported in horizontal position. 3.2 Temporary storage/conservation For temporary storage and conservation, it suffices if the unit is stored in a cool, dark, dry, and frost-protected place. The unit should be stored in horizontal position. 4. Description 4.1 General The sewage ejection units of the type series Kompaktboy are simplex units ready for connection, short-time flood-proof with gas tight and odour-tight collecting tanks made of plastics. They are operated with vertical, blockage-free sewage pumps with automatic, pneumatic level control. They are delivered with all necessary connectors Composition and mode of operation Due to the lateral inlets DN 50 and DN 100 or the upper inlet DN 50 / DN 100 (high temperature plastic sewage tube) Sewage (natural incline) is guided into the collecting tank of the sewage ejection unit Kompaktboy. In the impact pipe screwed into the top side of the tank the water rises and compresses the air in the impact pipe until the pressure actuates the dynamic pressure switch in the switch box. In doing so, the pump is switched on and transports the water from the tank through the pressure pipe into the higher located channel. A non-return valve integrated into the collecting tank prevents the backflow of the water from the pressure pipe into the tank The switching device is equipped with an alarm buzzer activated in case of a failure of the pump(s) or in case of an excessive water level in the tank. Furthermore, there are alarm contacts inside of the switching device for alarm systems (bell, buzzer, etc.) to be connected external. For the location, please refer to the circuit diagram of the switching device 7

8 5. Installation 5.1 Preparations - A correct and proper montage is pivotal for the failure-free operation of the pump station. For this reason, the following points must be observed: - The place of installation should be a well ventilated, dry and rust-free room. - The place of installation must be large enough. The ceiling heights should be approx. 2 to 2.5 m. According to DIN 1986 part 3, the following applies:...all parts of the unit...(and)...all control elements...must always be safely accessible and easy to operate....these parts of the unit must not be obstructed by stored parts, furniture, cover panels or several - The foundation of the installation room must be constructed for the possible loads depending on the dimensions of the unit. - In rooms mostly located lower, ground and leakage water is accumulated. Due to this fact, a small chamber should be located in a corner of the room, where the liquids will be accumulated and can be disposed of using a cellar drainage pump. - A ceiling hook below the place of installation of the pump station facilitates the assembly as well as possible maintenance and repair works on the pump. - Before starting the assembly, all structural and cable dimensions should be controlled and compared with the dimensions of the unit. In doing to, it is important to ensure that the continuously declining inlet pipe is located not deeper than the inlet height of the collecting tank Assembly During assembly, it is essential to ensure a zero-potential and tight installation of the pipelines and valves Placement The sewage ejection units of the type series Conpactboy will be adjusted on place of installation to existing pipelines. Here, it is placed in an exactly vertical position and fixed onto the floor using the included fixation screws. DIN part 1:...The excrements pump station must be designed in such a way that the fixing devices prevent torsion and buoying upwards Inlet The inlet pipe(s) will be connected to the included inlet bend and/or to the lateral inlets. It must be constantly declining. Inclining passages within the inlet are forbidden. The necessary inlets must be opened on the provided cutting edge using a saw. Important: When using the minimum inlet height of 180 mm it must be ensured, that the level control is adjusted in such a way, that the water level of the tank in normal operation slightly increases the lower edge up to a maximum filling of ½ of the inlet pipe before the pump switches on. In case of inlet pipes, dirt depositions in the inlet line are not excluded in this area and in extreme cases, the line could be blocked. This applies in particular to the lateral DN 50, due to the fact that they are entirely filled in every case before the pump is switched on. A connected drainage object must have its inlet minimum 180 mm above the installation level of the pump station! 8

9 5.2.3 Pressure pipe DIN part 3:...After breaking the discharge flow, backflow preventers must automatically prevent the backflow of the sewage from the pressure pipe. With the activation of the discharge, the backflow preventer must open automatically... This necessary non-return valve is already integrated into the pump station. It is recommended to mount a gate valve behind the non-return valve, in order to facilitate the cleaning and/or a possible replacement of the non-return valve The included seal ring (o-ring DN 100) for the connection of pressure sire of the pump station is mounted into the groove of the pressure outlet. The gate or, if no gate shall be used, the flange piece DN 100 included in the scope of delivery shall be fixed using 4 screws M 16. Otherwise the flange piece is mounted onto the gate. The flexible hose is plugged onto the flange piece and fixed using both included hose clamps. Now, the pressure pipe is inserted into the flexible hose and fixed using the 2 nd hose clamp. The pressure pipe must be laid in a constantly inclining manner and without unnecessary steps in a bend via the level of backedup water and afterwards constantly declining to the sewer junction. If necessary, pipelines and valves must be supported using pipe clamps or consoles Ventilation The tank ventilation (DN 75) is directly connected to the breather pipe of the building or installed through the roof Electrical connection Safety regulations All used electric devices must comply with the standard IEC 364 / VDE 0100, that means, that the electrical sockets must be equipped with earthing terminals. The electrical connection may only be effected by an electrically skilled person! The relevant VDE regulations 0100 must be respected! The mains to which the unit is connected must be equipped with a highly sensitive separate earth leakage circuit breaker IA <30 ma in front of the control or, in order to prevent a failure of the control when the earth leakage circuit breaker is activated, one earth leakage circuit breaker per pump must be installed between the control and the pump. In case of an installation in bath or shower rooms, the respective DIN VDE 0100 part 701 regulations must be respected. Please respect the regulations of the EN In case of a three-phase current supply, an external protection with automatic circuit breakers of characteristic K, in general 3-terminal mechanically blocked, must be executed. In doing so, the complete disconnection from supply is ensured and a 2- phase operation is excluded. All electrical devices, such as control, alarm sensor and power socket must be installed on a flood-proof position in dry rooms. Attention! Prior to every assembly and disassembly of the pump or other works on the unit, the unit must be disconnected from the mains. Due to an overload, the motor can overheat. Never touch the heat surfaces of the motor in case of an overheating. In case of using an extension cable, it must comply with the included connector cable concerning quality. The switching box must be mounted in such a way that the blue pneumatic hose for the pneumatic level control can be laid in a constantly inclining manner. This is indispensable to ensure a proper function of the automatic control. The connector of the simplex unit (CEEand/or earthing type) is directly connected before commissioning. The wiring diagram for the wiring of the pump station is located in the switching box and should be leaved there in order to facilitate the work of maintenance and after-sales-service staff. 9

10 6. Commissioning Before commissioning the unit, all connections must be checked for correct assembly; the non-return valve must be open. Now, the connector is plugged into the power socket and, in case of three-phase units, the rotational direction of the pump is checked. This is effected with briefly adjusting the hand/0/automatic-switch to hand and immediately actuating the stop switch. During running down of the motor, the rotational direction can be compared via the inspection glass on the upper side with the right rotational direction (directional arrow). If the pump rotates in wrong direction, two of the three phases must be changed. Disconnect the power supply before carrying out any kind of work on the unit! In case of using inlets DN 100 with 180 mm inlet height, the control is already adjusted. If inlets with higher inlet heights are exclusively used, other switching points can be adjusted on the control, in order to increase the backwater volume. Minimum inlet height Switching-off point N1 Switching-on point N2 High water HW Switching capacity 180 mm 0 cm 5 cm 7 cm 19 l 250 mm 0 cm 10 cm 13 cm 26 l 428 mm 0 cm 25 cm 29 cm 45 l Now, the button automatic is actuated and a test run is effected. For this purpose, a collecting tank is filled via the normal inlet (washbowl, toilet etc.). The unit must be automatically activated, pump out the tank and deactivated. After switching off, no water shall flow back from the pressure pipe into the tank. Depending on mounting conditions and discharge height, the follow-up time must be adjusted in such a way that the pump discharges the collecting tanks as far as possible and runs dry for a short time (loud noise during pumping). After the pumping process, the impact pipe shall not dip into the liquid (indication in the control 0 cm). The follow-up time may be adjusted in control device. During test run, all pipes and valves are checked again for tightness and tightened again, if necessary. If the pump station works properly, the switch rests in automatic position. 7. Maintenance/repair 7.1 Inspection- and maintenance intervals Inspection- and maintenance intervals according to DIN 1986 part 31: Sewage ejection units shall be checked by the operator once per month for serviceability and tightness by observing a monitoring cycle... The unit shall be maintains by an expert. The time intervals shall not be greater than 1 st ¼ year in case of units in industrial companies 2 nd ½ year in case of units in apartment buildings 3 rd 1 year in case of units in single family houses 7.2 Maintenance works Disconnect the power supply before carrying out any kind of work on the unit! 10

11 7.2.1 Collecting tank Open the inspection cover and squirt the tank using a hose, in order to lose sediments from the tank walls Non-return valve Close the gate valve of the pressure pipe, if existing. For exhaustion of sewage from the non-return valve, there is a drilled hole with a 1 internal thread and equipped with a dummy plug on the right side of the tank. On this point, it is possible to install e.g. a F+E stop cock. Open the inspection cover and clean the non-return valve from the inside Miscellaneous All continuative maintenance works must be effected by the after-sales-service. The following substances must not be fed: Solid materials, fibrous materials, tar, sand, cement, ash, rough paper, paper towels, paper boards, rubbish, garbage, offal, greases, oils. All drainage objects lying above the backwater level (EN ). Sewage with dangerous substances (DIN ), e.g. fatty sewage in industrial kitchens. The inlet may only be effected through a fat separator according to DIN

12 8. Malfunctions; causes and elimination Disconnect the power supply before carrying out any kind of work on the unit! In order to disassemble the motor unit from the tank, only the 8 Allen head screws (pos. 13 of the spare parts list) must be loosed. The 4 hexagon screws (pos. 5 of the spare parts list) must not be loosed, because otherwise, the seal ring will be destroyed, oil will escape and the guarantee expires! Failure Cause Removal - Voltage too low, no voltage - Check the supply 1. No motor rotation 2. Motor rotates but does not convey 3. Motor rotates and switches off 4. Motor does not switch off - Faulty power supply - Corrective measure - Electric cable defective - Replacement/after-salesservice - Failure in the condenser only in case of a 230 V pump - Replacement/after-salesservice - Running wheel blocked - Cleaning - Motor protection is switched off due to - Check/after-sales-service overheating, blockage, voltage failure - Control failure - Check/after-sales-service - Pneumatic hose and/or connection not tight - Check/replacement - Motor defective - Replacement/after-salesservice - Running wheel blocked or worn - Cleaning/replacement - Non-return valve blocked - Cleaning - Gate valve blocked or worn - Cleaning/open - Pressure pipe blocked - Cleaning - Intake fitting blocked - Cleaning - Wrong rotational direction - Corrective measure - Water deficiency in the tank - Deactivation/after-salesservice - Tank ventilation blocked - Cleaning - Pump housing ventilation blocked - Cleaning - Faulty voltage and/or variable - Corrective measure/after-salesservice - Over current release wrongly adjusted - Adjust it correctly - Power reception too high - After-sales-service - Control failure - After-sales-service 9. Warranty As manufacturer, for this product we provide a warranty of 24 months from date of purchase. Your sales receipt passes for verification. During that warranty period, we gratuitously remedy all deficiencies which are attributed to material or fabrication defects by either repairing the unit, or by replacing the defective parts (to our choice). Defects which are attributed to misuse or wear are excluded from warranty. We will assume no responsibility for consequential damages that are caused by a breakdown of the unit. 10. Technical modifications We reserve the possibility of technical modifications for the purpose of further development. 12

13 Appendix A: Installation example Flange piece DN110 with flexible connection piece Gate Flexible connection piece DN65 for the ventilation pipe 13

14 Appendix B: Dimensios Kompaktboy Revision hole Integrated nonreturn valve 1 Exhaustion Non-return valve 1 ½ connection hand diaphr. pump Inspection cover Impact pipe Pressure outlet 14

15 Appendix C: Sectional drawing and spare parts list Pos. Qty. Designation Article no. 2 1 Motor unit 1.1 kw-230 V with impeller Motor unit 1.1 kw-400 V with impeller Motor unit 1.5 kw-400 V with impeller Motor unit 3.0 kw-400 V with impeller O-ring 190 x Seal carrier Hexagon head screw M 12x25 ZE Oil filling 0.5 l Seal ring Fitting key ZE Impeller (1.1 kw) Ø 175 mm Impeller (1.5 kw) Ø 190 mm Impeller (3.0 kw) Ø 125 mm Running wheel cover compl. incl. pos.10,11,24 ZE O-ring 190x5 ZE Allen head screw M8x25 ZE Oil filling screw M 8x10 ZE Angle nozzle R 3/ Ventilation hose 0.25 m Hose clamp ZE Switching device simplex unit Condenser 50 µf for three phase current pump 1 Impact pipe cpl. simplex unit Control hose 5.5 m Collecting tank Kompaktboy with RSK Substitution gate for non-return valve E/ Seal for inspection cover of the non-return valve Inspection cover of pump station with seal

16 2010 by Zehnder GmbH 16

Sewage ejection units

Sewage ejection units Sewage ejection units Miniboy and Boy Boy Operation manual Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders... 4 1.3 Technical data...

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Operating instructions Spray nozzle SDU

Operating instructions Spray nozzle SDU Operating instructions Spray nozzle SDU INDEX Page 1. General... 2 2. Safety... 2 4 A. Nozzles type... 5 B. Nozzles inserts... 5 C. Revision... 5 D. Monitoring... 6 E. Heating... 6 F. Accessories... 6

More information

IP 900 W/KS & IP 900 D/KS

IP 900 W/KS & IP 900 D/KS B W/KS & D/KS Installation and operating instructions We reserve the right to make modifications in the interest of technical development (4) 15975178 GB 04/05 1 pplication reas The submersible waste-water

More information

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4

More information

JUNG PUMPEN BAUFIX 200. Instruction Manual

JUNG PUMPEN BAUFIX 200. Instruction Manual JUNG PUMPEN BAUFIX 200 EN Instruction Manual B 48216-10-1705 www.jung-pumpen.de Baufix 200-32 2 3 Qualification and training of personnel All personnel involved with the operation, servicing, inspection

More information

ABS lifting station Synconta

ABS lifting station Synconta 15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...

More information

Series description: Wilo-DrainLift KH 32

Series description: Wilo-DrainLift KH 32 Series description: Wilo-DrainLift KH 32 H[m] Wilo-DrainLift KH 32 4 3 2 1 Design Small sewage lifting unit (floor-mounted installation) Application Sewage lifting unit ready for connection for limited

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information

Installation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0

Installation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0 Installation and Service Instructions (Translation of the Original Instructions) SV20 Introduction Carefully read these Installation and Service Instructions prior to the installation and start of operation

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

Wilo-Control SC-Fire Jockey

Wilo-Control SC-Fire Jockey Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften

More information

UNIPUMP. Operating Instructions. Close Coupled Sewage pump Series K, HK, QSH. Internet

UNIPUMP. Operating Instructions. Close Coupled Sewage pump Series K, HK, QSH. Internet UNIPUMP Close Coupled Sewage pump Series K, HK, QSH Operating Instructions Also on the Internet! Herborner Pumpenfabrik J.H. Hoffmann GmbH & Co. House address: Littau 3-5 D-35745 HERBORN Phone ++49 (27

More information

Exchange of rollers from the XTS-Mover

Exchange of rollers from the XTS-Mover Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue

More information

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52.

BA EN.=A. Ä.=A.ä. Operating Instructions. Gearbox. Type 12. / 52. BA 12.0028 EN.=A. Ä.=A.ä Operating Instructions Gearbox Type 12. / 52. Product key Gearboxes 1 2... Product group Product family Gearbox size Design Geared motors 1 2... Product group Product family Gearbox

More information

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA 5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Operating Instructions. VOGEL-Pit Pumps Design WTS

Operating Instructions. VOGEL-Pit Pumps Design WTS Operating Instructions VOGEL-Pit Pumps Design WTS EC-Manufacturers Declaration (only valid for pump) acc. to Machine Directive 2006/42/EG Appendix II B of European Parliament and Council of 17.05.2006.

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

Starting up hydraulic systems

Starting up hydraulic systems General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable

More information

Pneumatic Axial Fan Type Tech. Doc. No. 802

Pneumatic Axial Fan Type Tech. Doc. No. 802 Pneumatic Axial Fan Type Tech. Doc. No. 802 Illustration can differ from the original Operation and Maintenance Manual Compiled: 06.08.13 815340300_en_Version_02 Page 1 of 11 ATTENTION!!! This pneumatic

More information

OWNERS MANUAL ECODIVER

OWNERS MANUAL ECODIVER OWNERS MANUAL ECODIVER ECO-DIVER Powerful multistage submersible pumps ideal for rain water systems, operating sprinklers, pumping water from tanks, cisterns, ponds and wells and other applications that

More information

Operating Instruction for Liquid-Ring Vacuum Pumps

Operating Instruction for Liquid-Ring Vacuum Pumps Operating Instruction for Liquid-Ring Vacuum Pumps Serial No Type EDUR-Pumpenfabrik Eduard Redlien GmbH & Co. KG Postfach 1949 D-24018 Kiel Tel. (+431) 689868 Fax (+431) 6898800 E-mail: info@edur.de http://www.edur.de

More information

VEM motors Thurm GmbH

VEM motors Thurm GmbH VEM motors Thurm GmbH Installation, Operating and Maintenance Instructions Single-Phase Squirrel-Cage Induction Motors, Standard Version March 2005 1. General To avoid damage to the motors and equipment

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24

Operating Instructions Garlock Butterfly Valves DN : mm / 2-24 Operating Instructions Garlock Butterfly Valves DN : 50-600 mm / 2-24 PN : 10 / 16 Type: GAR-SEAL SAFETY-SEAL STERILE-SEAL MOBILE-SEAL Conformity declaration... 14 0 Introduction... 15 1 Proper use...

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating instructions...2 2 Intended use...3 3

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP INDRA HYDR TECH PUMPS PVT. LTD. 16, 1st Floor, th Cross, 4th Phase, Peenya Industrial Area, Bengaluru

More information

Unilift KP 150, KP 250, KP 350

Unilift KP 150, KP 250, KP 350 GRUNDFOS INSTRUCTIONS Unilift KP 150, KP 250, KP 350 Installation and operating instructions DRAINAGE PUMP 1Z28 LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted

More information

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive Installation and Operation Instructions VAG ROTOP Portable Electric Drive KAT-B 5551 Edition 1-01/2018 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transport and Storage 3 2.1 Transport 3 2.2 Storage

More information

Dry installed pump type LANDY BTP.

Dry installed pump type LANDY BTP. OPERATION & MAINTENANCE MANUAL Dry installed pump type LANDY BTP. Landustrie Sneek BV Pieter Zeemanstraat 6 Tel. 0031 515-486888 P.O. BOX 199 Fax. 0031 515-412398 NL-8600 AD Sneek info@landustrie.nl The

More information

Adjustable Speaker Mount GRAVIS 12

Adjustable Speaker Mount GRAVIS 12 Adjustable Speaker Mount GRAVIS 12 User's Manual Translation of the original instructions Version 3.3 Released: 19.01.2017 Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße

More information

Adjustable Speaker Mount GRAVIS 8

Adjustable Speaker Mount GRAVIS 8 Adjustable Speaker Mount GRAVIS 8 User's Manual Translation of the original instructions Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0)

More information

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compact System NRGS 11-2 NRGS Original Installation Instructions English Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

Instruction Manual. * We reserve the right to amend specification without prior notice.

Instruction Manual. * We reserve the right to amend specification without prior notice. An IS 9001:200 certified company by Instruction Manual SSW SERIES 0.7 KW / 0.5 HP to 11 KW / 15 HP Declaration of Conformity Company Name Indra Hydro Tech Pumps Pvt. Ltd. Address 16, 4th Phase, th Cross,

More information

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings FLENDER ZAPEX couplings Type ZWT Operating instructions FLENDER couplings FLENDER ZAPEX couplings Type ZWT Operating instructions Translation of the original operating instructions Technical data Notes

More information

Aqualift F XL Lifting Stations

Aqualift F XL Lifting Stations Aqualift F XL Lifting Stations For industrial / high volume wastewater disposal Leading in Drainage Product Information Applications For use with wastewater from commercial, public and private sources

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified TPH Series MULTISTGE CENTRIFUGL PUMP Instruction Manual ISO 9001 Certified Walrus merica Inc 234867 EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. ddress: No. 83-14, Dapiantou, Sanjhih

More information

Technical Manual Electrical Power Supply System T4002

Technical Manual Electrical Power Supply System T4002 Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg

More information

ACO Haustechnik. Installation, Operating and Maintenance Manual B As per: 07/2010. ACO Sinkamat-K

ACO Haustechnik. Installation, Operating and Maintenance Manual B As per: 07/2010. ACO Sinkamat-K Installation, Operating and Maintenance Manual ACO Haustechnik 050.7.0 B As per: 07/200 Container ACO Sinkamat-K Below ground (D=400) ACO Sinkamat-K Small below ground lifting plant (D = 400) ACO Sinkamat-K

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

Operating Instructions

Operating Instructions BA 12.0028 450 298 EN Operating Instructions K12.0549 Typ Gearboxes 12.jjj 52.jjj Product key Gearboxes ➀ ➁ ➂ ➃ Product group Product family Gearbox size Design ➀ ➁ ➂ ➃ 12. 602. 20. 11 Geared motors ➀

More information

Operating Instructions Distributor ZP-A/G

Operating Instructions Distributor ZP-A/G INDEX Page 1. General... 2 2. Safety... 2 4 A. Distributor type... 4 B. Number of segments... 4 C. Inspection... 5 D. Monitoring... 5 E. Throttle insert... 5 F. Solenoid valve... 5 G. Coding of the outlets...

More information

DELTA PR2. Operating Manual. Sampling Valve. Read and understand this manual prior to operating or servicing this product.

DELTA PR2. Operating Manual. Sampling Valve. Read and understand this manual prior to operating or servicing this product. Operating Manual DELTA PR2 Sampling Valve Read and understand this manual prior to operating or servicing this product. UK Declaration of Conformity for Valves and Valve Manifolds SPX Flow Technology

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372 TPH Series MULTISTAGE CENTRIFUGAL PUMP Instruction Manual NSF/ANSI 372 ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.8314, Dapiantou,

More information

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS

JUNG PUMPEN COMPLI 100 MC SEWAGE LIFTING STATIONS APPLICATION The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets

More information

Operating manual Separator

Operating manual Separator Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport

More information

Differential Pressure Control Valve

Differential Pressure Control Valve Differential Pressure Control Valve www.ballorex.com 2 Table of contents Chapter Ballorex Delta DHC DN 15-150 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system

More information

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS APPLICATION The compli 1500 and 2500 tank systems have been designed for large industrial and communal wastewater volumes as well as for the connection of streets or other community effluent systems. In

More information

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life! Instructions and operation manual for butterfly valves This manual is intended to support the users of Herberholz butterfly valves type HRD/HRA, RD/RA, LDKE/LDKF for installation, operation and maintenance

More information

Instruction manual and installation guide Traction sheave brake TSB TSB

Instruction manual and installation guide Traction sheave brake TSB TSB Instruction manual and installation guide Traction sheave brake TSB 2000-1 TSB 2000-2 Content Traction sheave brake Page 1. Safety 2 1.1 Explanation of symbols 2 1.2. General safety instructions 3 2. Product

More information

OPERATING INSTRUCTIONS Thread unscrewing unit Z 5410, Z5420, Z5430

OPERATING INSTRUCTIONS Thread unscrewing unit Z 5410, Z5420, Z5430 STRACK NORMA GmbH & Co. KG Postfach 16 29 58466 Lüdenscheid Königsberger Str. 11 58511 Lüdenscheid Tel.: 0 23 51 / 87 01-0 Fax: 0 23 51 / 87 01-100 E-Mail: info@strack.de http://www.strack.de D 8138E 02.2009

More information

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product 77014 / 65041 Submersible Water Pumps Automatic Users Manual Carefully read this entire Instruction Manual before using this product Please read these operating instructions carefully and ensure they are

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! NEOTECHA These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions

More information

IU0U automatic charger Read these instructions carefully before the installation and commissioning and keep them in a safe place. Pass it on to the buyer in case of the further sale of the system. Contents

More information

Installation and Operating Instructions Magnetic Vibrator MR 1

Installation and Operating Instructions Magnetic Vibrator MR 1 Installation and Operating Instructions Magnetic Vibrator MR 1 (Translation of the Original Instruction Manual) Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 999824-00

More information

KESSEL-Grease Separator Under sink

KESSEL-Grease Separator Under sink INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL-Grease Separator Under sink Order Number 93025.00/US Product advantages Compact structure fully adjustable inlet 290 to 420 260 350 release

More information

Assembly and Maintenance Manual Type AS

Assembly and Maintenance Manual Type AS Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx

More information

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Pneumatic or Electropneumatic Positioner for Rotary Actuators Type 3761 Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition June 2004 Contents Contents Page 1 Design and

More information

Operating and installation instructions

Operating and installation instructions Strainer PN6-160 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols... 2-2 2.2 Explanatory notes on safety information... 2-2 3.0 Storage

More information

Installation and Operational Instructions for ROBA -D Couplings Type 91_. _

Installation and Operational Instructions for ROBA -D Couplings Type 91_. _ Please read the Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to coupling failure, resulting in damage to other

More information

HST-BL-2830MS & HST-BL-2830MS-USA

HST-BL-2830MS & HST-BL-2830MS-USA HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Ama-Drainer N 301/302/303

Ama-Drainer N 301/302/303 Submersible Motor Pump Ama-Drainer N 301/302/303 60 Hz Installation/Operating Manual Legal information/copyright Installation/Operating Manual Ama-Drainer N 301/302/303 Original operating manual All rights

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Issue 12-2013 Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Figure 1: Coupling complete Figure 4: Coded coupling, complete Table of

More information

Operating and installation instructions

Operating and installation instructions Pneumatic actuators DP34 Tandem / DP34 Tridem DP34T Contents DP34Tri 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols...2-2 2.2 Explanatory

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

M A N U A L. Field Current Controller F2.2

M A N U A L. Field Current Controller F2.2 M A N U A L Field Current Controller F2.2 Industrie Elektronik G m b H Hans-Paul-Kaysser-Straße 1 71397 Leutenbach Nellmersbach Tel.: 07195 / 92 83 0 Fax: 07195 / 92 83 129 info@unitek-online.de www.unitek-online.de

More information

JUNG PUMPEN compli 100 MC Sewage lifting stations

JUNG PUMPEN compli 100 MC Sewage lifting stations Application The sewage lifting stations compli 100, compli 500 and compli 1000 with MultiCut cutting system are uses especially for disposal in special objects, such as weekend cottages, houseboats, toilets

More information

KeContact P20. User manual

KeContact P20. User manual KeContact P20 User manual Comments to this manual In this manual you will find warnings against possible dangerous situations. The used symbols apply to the following meanings:!! WARNING! Indicates a potentially

More information

Contamination switch VS

Contamination switch VS Contamination switch VS RE 95148 Issue: 12.2015 Replaces: 09.2015 For detecting metallic impurities in oil Inhalt Ordering code 2 Description 2 Technical data 2 Connection 3 Dimensions 3 Safety instructions

More information

Application cup for OptiFlex 2 GM03 manual powder gun

Application cup for OptiFlex 2 GM03 manual powder gun En Operating instructions and spare parts list Application cup for OptiFlex 2 GM03 manual powder gun Translation of the original operating instructions Documentation OptiFlex GM03 application cup Copyright

More information

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning. Declaration of Conformity Operating Instructions Rolli D6/5A 440209101-A 03/2004 Subject to technical alterations. Text and design copyrighted. Reprinting and copying, even if excerpts, only with written

More information

Compensation unit AGE-XY 50-80

Compensation unit AGE-XY 50-80 Translation of the origninal manual Compensation unit AGE-XY 50-80 Assembly and operating manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted property of

More information

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps UNPK04DC Pressure UNPK04DCB Pressure UNPK04DC Vacuum UNPK04DCB Vacuum KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ

More information

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List

LOG CHOP. Hydraulic Wood Guillotine. Owners Illustrated Instruction Book & Parts List LOG CHOP Hydraulic Wood Guillotine Owners Illustrated Instruction Book & Parts List Grovebury Road, Leighton Buzzard, Bedfordshire. LU7 4UX. UK. Tel:01525 375157. Fax:01525 385222. Email: enquires@brownsagricultural.co.uk

More information

Spare Parts List Return line filter RF

Spare Parts List Return line filter RF Spare Parts List Return line filter up to 15000 l/min, up to 25 bar 30 60 110 160 240 330 450 580 660 950 1300 2500 4000 5200 6500-7800 15000 1. MAINTENANCE 1.1 GENERAL Please follow the maintenance instructions!

More information

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use! Operating instructions Pneumatic Crimper AC 100 Date of issue: 05/2010 Keep for future use! SAFETY SAFETY Basic information The basic prerequisite for ensuring safe use and continuous operation of the

More information

SCOPELITE TIMING LIGHT OPERATING MANUAL

SCOPELITE TIMING LIGHT OPERATING MANUAL SCOPELITE TIMING LIGHT OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.020-EN Rev. 11/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and

More information

Operating and installation instructions

Operating and installation instructions Series 470 Series 471 Contents 1.0 General information on operating instructions...2-2 2.0 Notes on possible dangers...2-2 2.1 Significance of symbols... 2-2 2.2 Explanatory notes on safety information...

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A utomatic trailer coupling Repair instructions 5KPVM02000 Towing Hitch utomatic Rockinger RO244 5KPVM02010 Towing Hitch utomatic Rockinger foot operated RO244L Contents 1 General Validity and application

More information

Operating Manual Hot Melt Applicator. Tec 4500B / Tec 4500S

Operating Manual Hot Melt Applicator. Tec 4500B / Tec 4500S Operating Manual Hot Melt Applicator Tec 4500B / Tec 4500S Table of Contents 1 General 4 1.1 Scope of use 4 1.2 Technical data 4 2 Safety instructions 5 2.1 Potential hazards 5 2.2 Instructions for safe

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Operating instructions ErgoPack 600 E

Operating instructions ErgoPack 600 E Operating instructions ErgoPack 600 E Operation of the device is only permitted if the operating instructions have been carefully read and understood before use! Declaration of conformity EU declaration

More information

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions

BoWex FLE-PA. BoWex FLE-PAC. KTR-N Sheet: Edition: EN 1 of BoWex FLE-PA / FLE-PAC Operating/Assembly instructions 1 of 17 is a torsionally rigid flange coupling. It is able to compensate for shaft misalignment, for example caused by manufacturing inaccuracies, thermal expansion, etc. BoWex FLE-PA BoWex FLE-PAC Drawn:

More information

Analytical Diaphragm Pump Series MP MP06, MP12

Analytical Diaphragm Pump Series MP MP06, MP12 Analytical Diaphragm Pump Series MP MP06, MP12 Instruction Manual Version 1.00.01 Dear customer, we have made up this operating manual in such a way that all necessary information about the product can

More information

Original Operating Manual CVP High-Pressure Centrifugal Pump

Original Operating Manual CVP High-Pressure Centrifugal Pump Original Operating Manual CVP High-Pressure Centrifugal Pump OSNA-Pumpen GmbH Brückenstrasse 3 49090 Osnabrück, Germany Phone: +49 541 1211-0 Fax: +49 541 1211-220 Internet: http://www.osna.de E-mail:

More information

Lifting Station Type ABS Synconta 900B

Lifting Station Type ABS Synconta 900B 310.190.014.010 EN (01/2017) 1068-00 EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) 901B 902B Symbols and notices used in this

More information

Assembly Instructions

Assembly Instructions Rev.. Assembly Instructions - Hand Spray Valve SMS-6 Page of 20 Assembly Instructions Hand Spray Valve SMS-6 Article Number: S6- NOTE Please read the Assembly Instructions carefully before first using

More information