Pneumatic Axial Fan Type Tech. Doc. No. 802

Size: px
Start display at page:

Download "Pneumatic Axial Fan Type Tech. Doc. No. 802"

Transcription

1 Pneumatic Axial Fan Type Tech. Doc. No. 802 Illustration can differ from the original Operation and Maintenance Manual Compiled: _en_Version_02 Page 1 of 11

2 ATTENTION!!! This pneumatic axial fan must be operated at a maximum pressure of 4 bar only and therefore it has to be equipped with a pressure governor ref R ¾. Compiled: _en_Version_02 Page 2 of 11

3 TECHNICAL SPECIFICATION At an operation pressure of 4 bar: Nominal diametre mm 600 Unit length mm 520 Weight kg 58 Max. operating pressure Air consumption (blowing) Volume flow (unrestricted discharge) bar 4 m³/min m³/s 3.84 (135 cfm) 5.83 ( cfm) Hose diametre mm 19 ATEX Classification Group II Category 2 G c T 6 Description The pneumatic axial fans comply with the provisions of the Directive 94/9/EC (Atex 95a). Any surfaces between the rotating and fixed components which could normally be expected to come into contact during operational faults are made of materials with reduced risk of ignition due to friction or contact sparks. Compiled: _en_Version_02 Page 3 of 11

4 SAFETY INSTRUCTIONS The following symbols refer to particular dangers or give advice for save operation. Attention! Danger! Safety advice! Important information Spitznas axial fans are not ready for use products and must only be used after having been fitted to machines, ventilation devices and systems or after their safety has been ensured through the use of protection against contact (DIN EN 294) or other construction devices. Spitznas axial fans are produced in accordance with the latest technical standards. Our quality assurance programme (DIN EN ISO 9001:2000) which includes material and function tests, ensures that the final product is of a high quality and durability. Nevertheless these fans can be dangerous if they are not used and installed correctly, according to the instruction. Before installing and operating this fan read this instruction carefully! Only use the fan after it has been securely mounted and fitted with protection against contact or protective grilles to suit the application. Remove protective grilles only for cleaning. Subsequently assemble again. Before working on the fan always disconnect air hose. Earth the fan against static electrification! Compiled: _en_Version_02 Page 4 of 11

5 Use Intended use Conveying of big volume flows through pipes, as well as for ventilation and de-aeration for the following applications: - ship construction - refineries - chemical industry Conveying of gas Improper use Working without personal protective equipment. The operator is liable for defects due to improper use. Danger zones Operational condition Life phase Transport Operation Normal function Malfunction Improper use Expected use Transport of the machine in an inoperable condition Machine only works with actuated switch Drop of the machine Machine runs without actuated switch Transport of the machine in an operable condition Switch is blocked in actuated condition unknown unknown Compiled: _en_Version_02 Page 5 of 11

6 OPERATION INSTRUCTIONS Conditions of use Please ensure no foreign matter, e.g. paint particles, gets into the airflow and causes damage to the impeller, as it can generate static charging by friction, which can cause an explosion. Storage, Transport Store fan in its original package in a dry place and protect it against the weather. If stored for a long period, check the impeller bearing move freely by turning it by hand. Installation Ensure that fans are mounted by competent, trained personnel. Protective grills are mounted at the air inlet and outlet ends to avoid foreign substances falling inside or being sucked in. Do not install without proper support Be careful not to damage the casing or any moving parts Do not apply unnecessary force e.g. levering, hammering when installing For all work on the fan Assembly Operation Service Maintenance care should be taken that the gap between the fan wheel and the fixed housing components is regular. The minimum distances must be at least 1% of the greatest contact diameter, but no less than 2 mm. The gaps are already considered at production. Compiled: _en_Version_02 Page 6 of 11

7 Operation Operating pressure: 4 bar Before starting blow out the air hose and connect it to the fan. Do not lubricate the turbine. Do not fit a line oiler or inject oil into the hose. Maintenance Repair of the fan should only be performed by qualified and skilled workers in accordance with applying regulations. General checking: Bearing clearance to large? Emerged lubricant on the bearing? Unusual noise? The bearings are maintenance-free and have not to be lubricated. Spare Parts Only original spare parts may be used. There is no warranty for damages and liability is disclaimed, if non-original spare parts and accessories are used. Compiled: _en_Version_02 Page 7 of 11

8 Description: Pneumatic Axial Fan Spare Part List Part and drawing number: Item Qty. Description Part and drawing no. Remarks 1 1 Air duct sheet metal Fan housing inlet Hexagonal screw Hexagonal nut Toothed lock washer Fan housing exhaust Hexagonal screw Hexagonal nut Toothed lock washer Air duct sheet metal Hexagonal screw Hexagonal nut Toothed lock washer Toothed washer Hexagonal screw End cover Self- aligning ball bearing Shaft with pin Spacer tube Self-aligning ball bearing Bearing cover Toothed lock washer Hexagonal screw Impeller wheel, Assy Hexagonal screw Toothed lock washer Upstream hood Spring washer Socket head screw Hexagonal screw Toothed lock washer Compiled: _en_Version_02 Page 8 of 11

9 Description: Pneumatic Axial Fan Spare Part List Part and drawing number: Item Qty. Description Part and drawing no. Remarks 32 1 Downstream hood Nozzle Stop valve Pipe nut Thread piece Internal thread coupling Compiled: _en_Version_02 Page 9 of 11

10 Description: Pneumatic Axial Fan Spare Part List Part and drawing number: Compiled: _en_Version_02 Page 10 of 11

11 We, the company Installation Declaration as defined in the European Union Machine Directive 2006/42/ EC SPITZNAS Maschinenfabrik GmbH, Fellerstraße 4, Velbert Langenberg, declare, that the following product Description: Pneumatic Axial Fan Model: complies with the provisions of the European Union Machine Directive 2006/42/ EC and 94/9 EC (Atex 95 group II, category 2, G c T6) and conforms to the following standards or standardized documents: DIN EN ISO DIN EN DIN EN DIN EN VDMA 24169, Part 1 ISO 14694:2003 According to section 8 (1) ii) of the directive 94/9/EC technical documentation is deposited under reference No. 968/Ex-AB 717/05 at the following office: TÜV Rheinland Industrie Service GmbH Haumannplatz 4, Essen (Registration No for the scope of the Directive 94/9/EC) Requirement for the operation of this machine is that the complete machine, into which it is installed, corresponds to the regulations of the European Union Machines Directive, the harmonised standards, the European standards or the relevant national security standards. Name of the authorized person for documentation: Mr. Simon Witt Address of the authorized person for documentation: see manufacturer s address Velbert, Compiled: _en_Version_02 Page 11 of 11

Hydraulic Impact Wrench Type

Hydraulic Impact Wrench Type M a s c h i n e n f a b r i k G m b H Hydraulic Impact Wrench Type 6 1520 0010 Illustration can differ from the original Operation and Maintenance Manual 615200010_en_Version_03 Page 1 of 19 TECHNICAL

More information

Hydraulic Rotary Hammer Drill

Hydraulic Rotary Hammer Drill M a s c h i n e n f a b r i k G m b H Hydraulic Rotary Hammer Drill Type 2 2406 0010 Techn. Doc. No. 262 Illustration can differ from the original Repair Manual and Spare Parts List 224060010_Inst_en_Version_06.doc

More information

Hydraulic Rotary Hammer Type also for underwater application

Hydraulic Rotary Hammer Type also for underwater application M a s c h i n e n f a b r i k G m b H Hydraulic Rotary Hammer Type 2 2418 0010 also for underwater application Illustration can differ from the original Operation and Maintenance Manual 224180010_BA_en_Version_06

More information

User Instruction SUPER-PM ATEX. Note! Before installation and use in application follow the instructions

User Instruction SUPER-PM ATEX. Note! Before installation and use in application follow the instructions User Instruction SUPER-PM ATEX Note! Before installation and use in application follow the instructions PLYMOTH-PLYMEX GmbH Zilzkreuz 14 53 604 Bad Honnef Tel.: 02224/98853-0 Fax: 02224/98853-22 e-mail:

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Pneumatic Angle Grinder also for Underwater Use Type

Pneumatic Angle Grinder also for Underwater Use Type M a s c h i n e n f a b r i k G m b H Pneumatic Angle Grinder also for Underwater Use Type 1 4311 0050 Illustration can differ from the original Repair Manual and Spare Parts List Compiled: 22.06.11 143110050_Inst_en_Version_00

More information

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Specifications Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16). Housings: PP* Single block strong high density UV treated and

More information

Operation and Maintenance Manual

Operation and Maintenance Manual Hydraulic Drive Unit Type Techn. Doc. No. 362 and Accessories for Pipe Cutting Machine Illustration can differ from the original Operation and Maintenance Manual 580067000_BA_en_Version_03 Directory Signal

More information

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Powerful centrifugal fans for universal use: The product ranges TEM and REM Powerful centrifugal fans for universal use: The product ranges TEM and REM The fan ranges TEM and REM offered by Nicotra Gebhardt do present a large fan programme of single inlet centrifugal fans which

More information

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200

More information

USER MANUAL. TSK and TSK V.

USER MANUAL. TSK and TSK V. USER MANUAL TSK and TSK V www.sisteven.com Types of roof fan: TSK TSK V 1. Start All fans produced by SISTEVEN, hereinafter the manufacturer, and the full line of accessories, have been manufactured in

More information

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10. 27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use! Operating instructions Pneumatic Crimper AC 100 Date of issue: 05/2010 Keep for future use! SAFETY SAFETY Basic information The basic prerequisite for ensuring safe use and continuous operation of the

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Support T10552 T10595 T40386

Support T10552 T10595 T40386 T10552 T10595 T40386 en-gb 7 T10552 T10595... 1 General Information Product name: Product type: Product number: Weight: Max. load capacity: Static test coefficient: 3.0 Intended Use: Load holding device

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800 Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ

More information

Pneumatic Corner Drill

Pneumatic Corner Drill Mashinenfabrik GmbH Pneumati Corner Drill Type 2 1701 0000 2 1701 0010 2 1701 0030 Teh. Do. No. 202 Illustration an differ from the original Operation and Maintenane Manual Spitznas Mashinenfabrik GmbH,

More information

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA 5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page

More information

Pneumatic Circular Saw. Type Illustration can differ from the original. Spare Parts List

Pneumatic Circular Saw. Type Illustration can differ from the original. Spare Parts List Pneumatic Circular Saw Type Illustration can differ from the original Cleaning Regular cleaning is required for a continuous and proper operation. Clean the housing regularly with a soft cloth, it is important

More information

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve Series V2001 Valves Type 3321 Globe Valve Type 3321 Globe Valve with rod-type yoke and Type 3372 Electropneumatic Actuator (350 cm²) Mounting and Operating Instructions EB 8111/8112 EN Edition June 2013

More information

Instruction Manual. Sewage lifting station compli 300

Instruction Manual. Sewage lifting station compli 300 Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803

More information

Operating Instructions Inline Detonation Flame Arrester and

Operating Instructions Inline Detonation Flame Arrester and Operating Instructions Inline Detonation Flame Arrester 1002-0008 and 1002-0009 0102 PTB 04 ATEX 4003 X IIG IIB3 Issue : 27.11.2007 Page 1 of 7 1. Preface These operating instructions apply to inline detonation

More information

Operating Instructions

Operating Instructions Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2

More information

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Document number 480938 AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Use this manual when AMS and AMD series dampers were purchased prior

More information

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML

Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive. Series CNH-ML Volute Casing Centrifugal Pumps in High Temperature Design with Magnetic Drive Series CNH-ML Usage For pumping toxic, volatile, explosive or other fluids harmful to the environment which call for service

More information

c-go 24V/6A 24V/8A 24V/12A

c-go 24V/6A 24V/8A 24V/12A c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...

More information

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning. Declaration of Conformity Operating Instructions Rolli D6/5A 440209101-A 03/2004 Subject to technical alterations. Text and design copyrighted. Reprinting and copying, even if excerpts, only with written

More information

Easytork Solenoid Valve IOM

Easytork Solenoid Valve IOM Easytork Solenoid Valve IOM General This installation document is to be read in conjunction with the Easytork Vane Actuator IOM. Description The Easytork Solenoid Valve ( ESV ) series is intended for the

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

RESOL SBS 1000 * * Connection Operation

RESOL SBS 1000 * * Connection Operation RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this

More information

Pneumatic grease pump 50:1 and grease supply system

Pneumatic grease pump 50:1 and grease supply system Pneumatic grease pump 50:1 and grease supply system 03 591 A411 GB G Operating instructions for Pneumatic grease pump 50:1 Contents 1. General Information 2 1.1 Usage Stipulations 2 1.2 Construction &

More information

Storage, operating and maintenance instructions for AZ plug valves and Standard valves

Storage, operating and maintenance instructions for AZ plug valves and Standard valves ARMATUREN Plug - Valves metallic with PTFE Sleeve 2-7 way Storage, operating and maintenance instructions for AZ plug valves and Standard valves Plug - Valves FEP/PFA - lined, 2-3 way Butterfly - Valves

More information

Service - Safety Manual

Service - Safety Manual Service - Safety Manual Mounting and maintenance instructions Linear Units LT50 series Code Unit Serial number Date by Linear Units LT50 series Table of contents 1 Safety 3 1.1 Significance of the manual

More information

Installation and Operating Instructions. Vibratory hopper. Type BV. Type BVL

Installation and Operating Instructions. Vibratory hopper. Type BV. Type BVL Installation and Operating Instructions Vibratory hopper Type BV Type BVL Table of Contents 1. General... 4 1.1. Pin assignment... 4 2. Safety directives... 7 2.1. Applicable directives and standards...

More information

Operating Instruction Inline Detonation Flame Arrester

Operating Instruction Inline Detonation Flame Arrester Operating Instruction Inline Detonation Flame Arrester 1002-0008 IBExU 11 ATEX 2071 X 0102 G IIB3 Issue : 05.04.2012 Page 1 of 7 1. Preface These operating instructions apply to inline detonation flame

More information

Diaphragm-Gas Sampling Pumps

Diaphragm-Gas Sampling Pumps Diaphragm-Gas Sampling Pumps N 143 ANE N 143 ATE Operating and Installation Instructions Read and observe these Operating and Installation Instructions! N 186.1.2 ANE N 186.1.2 ATE KNF Neuberger GmbH Alter

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC ... 3... 4 3000 rpm 50 Hz / 3600 rpm 60 Hz... 4... 5... 7 Modular pump / motor systems... 7 Materials...........................................................

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11 Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the brake and any damage may be caused by not observing it. Table of contents: Page 1: Page 2: Page 3:

More information

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x) Operating Instructions Installation Information METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x) www.mt.com/support Content 1. General information... 4 2. Safety instructions...

More information

BR 31a Rack-and-pinion Actuator,

BR 31a Rack-and-pinion Actuator, Operating, assembly and maintenance instructions BR 31a Rack-and-pinion Actuator, SRP and DAP 1. General These instructions are intended to support the user in the assembly, maintenance, and repair of

More information

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin INDUSTRY PROCESS AND AUTOMATION SOLUTIONS Technical Bulletin Guidelines for selection of planetary gear units of the 300- INDUSTRIAL series for installation in hazardous areas, classified by Directive

More information

Instruction Manual. Maple 8/25 Pump. Model

Instruction Manual. Maple 8/25 Pump. Model Maple 8/25 Pump Model 10 40 42 Note: Read and follow all instructions and safety precautions before using this equipment 104042 - Maple 8/25 Pump Product Description This equipment is designed for use

More information

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 , IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7 Please read these Installation and Operational Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunction or to clutch failure, resulting in damage to other

More information

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales Operating instructions METTLER TOLEDO MultiRange Floor scales/pit scales KC300...x-T4 / KCS300...x-T4 KC600...x-T4 / KCS600...x-T4 KD600...x-T4 / KD1500...x-T4 KE1500...x-T4 / KE3000...x-T4 KES1500...x-T4

More information

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 , IECEx PTB 14.0049X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

MZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift

MZ Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift 90 D C MZ 002-099-4115 Instruction manual Mode d emploi Betriebsanleitung Istruzioni d uso Manual de instrucciones Installatie voorschrift CE Certificate of Conformity Actaris Gaszählerbau GmbH 76161 Karlsruhe

More information

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system

More information

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun

SB-E-2-CBA1 ISS.13. Operation Manual Cobra 1 Automatic Spray Gun EN SB-E-2-CBA1 ISS.13 Operation Manual Cobra 1 Automatic Spray Gun Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this equipment

More information

DECLARATION OF PERFORMANCE DoP N EN

DECLARATION OF PERFORMANCE DoP N EN CONSTRUCTION PRODUCTS REGULATION (EU) 305/2011 DECLARATION OF PERFORMANCE DoP N 006-01-EN 1. Unique identification code of the product type: panic device according to DIN EN 1125:2008-04 1309-CPD-0194

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours MIE TALK - July 2016 Compiled by Pieter H. Coetzee Introduction Far too many fires and burn injuries result from the careless or inappropriate use of petrol. Because petrol is so common in our environment,

More information

Operating Instruction

Operating Instruction Operating Instruction Drive element LEWA - ecosmart type LCA with manual stroke adjustment, motor mounted vertically Table of contents 1 General information / safety 1.1 Important preliminary information

More information

Service - Safety Manual

Service - Safety Manual Service - Safety anual ounting and maintenance instructions Linear Units LT55 and LT80 series Code Unit Serial number Date by Linear Units LT55 - LT80 series Table of contents Safety 3. Significance of

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Snow blade SRM-FB 120 CD Angle adjustment mechanical Version

More information

Declaration of Conformity as per Directive 97/23/EC

Declaration of Conformity as per Directive 97/23/EC Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear

More information

Solutions beyond products...

Solutions beyond products... ORIGINAL INSTRUCTIONS IH102C Installation, Operation & Maintenance Manual Model B177 External Automatic Bypass Valve Model B177 External Automatic Bypass Valve Warning: (1) Periodic inspection and maintenance

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

Micro Diaphragm Gas Sampling Pumps

Micro Diaphragm Gas Sampling Pumps Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP830K_DC-M HP NMP830.1.2K_DC-M HP NMP830K_DC-B HP NMP830.1.2K_DC-B HP NMP830K_DC-B4 HP NMP830.1.2K_DC-B4 HP You

More information

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL

TB SERIES PUMPS TBS OPERATION & PARTS MANUAL TB SERIES PUMPS TBS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Company Standard Mounting Instructions for Type Valves with Type AT Actuator

Company Standard Mounting Instructions for Type Valves with Type AT Actuator Mounting Instructions for Type 72 82-62 Valves with Type AT Actuator Introduction These installation instructions contain important information on the installation, functioning, maintenance and storage

More information

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal... Safety sensor 7 Disassembly and disposal 7.1 Disassembly....5 7.2 Disposal...5 8 Appendix 8.1 Wiring example...6 Operating instructions.............pages 1 to 8 Original 9 EU Declaration of conformity

More information

HST -LS Interlocking device (Translation of Original Manual)

HST -LS Interlocking device (Translation of Original Manual) Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image

More information

Operating Instruction Electro hydraulic workshop presses HPE

Operating Instruction Electro hydraulic workshop presses HPE Operating Instruction Electro hydraulic workshop presses HPE Type Serial number Date Rev. A 116967 07/2011 EC Declaration of Conformity according to EC directive 2006/42/EC on machinery Typ Hier Typenschild

More information

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content Pull-wire emergency-stop switches 1. bout this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for

More information

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50 Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50 AK-Ex with electric actuator II 2G c II TX II 2D c II T 80 C AK-Ex with pneumatic actuator II 2G c IIB TX

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N145 AN.18 N145 AT.18 N145 AV.18 N145.1.2 AN.18 N145.1.2 AT.18 N145.1.2 AV.18 KNF Neuberger

More information

Operation & Technical Manual. Model: Ground Test Motor

Operation & Technical Manual. Model: Ground Test Motor Operation & Technical Manual Model: 13-6604-6600 Ground Test Motor 05/2009 Rev. 05 Includes Illustrated Parts Lists DEVELOPED IN CONJUNCTION WITH HAMILTON-SUNDSTRAND 1740 Eber Rd Tronair, Inc. Phone: (419)

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

Hydraulic Angle Grinder for Underwater Use Type

Hydraulic Angle Grinder for Underwater Use Type M a s c h i n e n f a b r i k G m b H Hydraulic Angle Grinder for Underwater Use Type 1 1585 0010 Illustration can differ from the original Repair Manual and Spare Parts List Compiled: 18.01.13 115850010_Inst_en_Version_03

More information

2/2 Solenoid Cartridge Valve, Size 6

2/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof

More information

Multi-Mover Charger for model L25

Multi-Mover Charger for model L25 Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS

More information

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444 Operation Instructions (translation) Explosion Protection Explosion protection is one option and is marked on the ex-type plate on the solenoid drive. The actuators and the associated solenoid controllers

More information

Operation Manual Cobra 1 Automatic Spray Gun

Operation Manual Cobra 1 Automatic Spray Gun SB-E-2-CBA1 ISS.06 Operation Manual Cobra 1 Automatic Spray Gun E P 1 12 1 Operation Manual Cobra 1 Automatic Spraygun Important Read and follow all instructions and Safety Precautions before using this

More information

INSTRUCTION MANUAL IS2.003

INSTRUCTION MANUAL IS2.003 INSTRUCTION MANUAL IS2.003 INSTALLATION, USE and MAINTENANCE FOR FANS IN CONFORMITY WITH THE PROVISIONS OF DIRECTIVE 2014/34/UE II 2G c IIB IIB+H2 T3* / 2D c T 195 C * UNI EN 1127-1, UNI EN 13463-1, UNI

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC. INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL ORBINOX SPAIN PolInd s/n-20270 ANOETA Tel:+34 943 698030 Fax:+34 943 653066 e-mail:orbinox@orbinoxcom ORBINOX CANADA, ORBINOX USA,, ORBINOX BRAZIL, ORBINOX

More information

Operating manual Separator

Operating manual Separator Operating manual Separator Sheet no. AS/4.1.141.1.1 issue 20.08.2014 Contents Section Title Page 0 Introduction... 1 1 Intended use......1 2 Marking of the fitting... 1 3 Safety instructions... 2 4 Transport

More information

Installation and Operating Instructions Magnetic Vibrator MR 1

Installation and Operating Instructions Magnetic Vibrator MR 1 Installation and Operating Instructions Magnetic Vibrator MR 1 (Translation of the Original Instruction Manual) Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 999824-00

More information

Repair Manual and Spare Parts List

Repair Manual and Spare Parts List Pneumatic Drive Unit Type Techn. Doc. No. 352 and Accessories for Pipe Cutting Machine Darstellung kann vom Original abweichen Repair Manual and 580027000_Inst_en_Version_02 Repair General In general,

More information

R o L. WAFER PATTERN V-PORT BALL VALVE stainless steel 465 series SILVER LINE. Operation. Description. Edition

R o L. WAFER PATTERN V-PORT BALL VALVE stainless steel 465 series SILVER LINE. Operation. Description. Edition Operation WAFER PATTERN V-PORT BALL VALVE stainless steel C ont R o L Description Edition Högfors ball sector valve series 465 is specially designed for control applications of various medium like liquids,

More information

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY PRODUCT OVERVIEW The VADA series of self priming jet pumps combine the functional benefits of centrifugal pumps and the practical and qualitative benefits of self-priming pumps. The Venturi system the

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Centrifugal performance characteristics with axial flow pattern: RADAX VAR High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers

More information

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual SBS 2000 Filling and flushing station Manual for the specialised craftsman Connection Operation Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from

More information

HILLSTONE DC LOAD BANK

HILLSTONE DC LOAD BANK OPERATING MANUAL for HILLSTONE DC LOAD BANK Type ref. HLD 240 480 100 Serial No. M36771 ISSUE 1 1 CONTENTS Introduction page 3 Safety Considerations page 3 Connecting procedure page 4 Operating instructions

More information

Original Operating Manual

Original Operating Manual matev GmbH Nürnberger Str. 50 90579 Langenzenn T +49 (0) 9101 9087-0 F +49 (0) 9101 9087-20 info@matev.eu www.matev.eu Original Operating Manual Front Power System und Front PTO shaft FPS- JD X 950 R for

More information