ADVANCED FIRE SUPPRESSION TECHNOLOGIES STORED AFFF BULK SYSTEM 150/250/350

Size: px
Start display at page:

Download "ADVANCED FIRE SUPPRESSION TECHNOLOGIES STORED AFFF BULK SYSTEM 150/250/350"

Transcription

1 ADVANCED FIRE SUPPRESSION TECHNOLOGIES STORED AFFF BULK SYSTEM 150/250/350 S REV(30/09/2015) Page 1 of 25

2 Introduction The Advanced 150/250/350 AFFF Bulk fire suppression system is a pre-engineered, fixed nozzle system for protection of off-highway and equipment, power packs, lubrication rooms and oil storage area s. Each system application will need to be designed specifically for equipment intended for protection. Typical applications include surface mining equipment, underground mining service bays, forest harvesting equipment, land fill equipment, and construction equipment. The Advanced 150/250/350 AFFF bulk system consists of three major components; a container to store the AFFF extinguishing agent; an actuation system operated manually or automatically and an agent distribution system which delivers the agent from the tank through the hydraulic hose and fixed nozzles to the hazard area. The system described in this manual is a fire suppression system and is not designed or intended to extinguish all fires, particularly when unusual amounts of combustible materials and ample oxygen supply are present. It is extremely important that supplement firefighting equipment be available in case the system does not totally extinguish a fire. If an automatic fire detection and actuation system has not been supplied or has been disconnected, the system actuation and discharge will not occur unless the fire suppression system is manually operated. Reliance on a manual release system usually results in a slower reaction to fire. Means to automatically shut down the vehicle must be added to manual or disconnected automatic system. Ansulite 6% [per liter] P/N: FOAM S REV(30/09/2015) Page 2 of 25

3 How The System Operates Discharge of the Advanced Bulk system manually is initiated from an automatic or manual actuator. Automatic operation or manually depressing the actuator plunger punctures the seal on the cartridge. The released pressure is transmitted through the actuation line. A safety relief valve in the actuation line prevents too high an actuation pressure build up. When pressure from the actuator manual/automatic, reaches the valve head, it opens the piston situated in the valve. This in essence will allow the pre-pressurized system to discharge through the separate pipe network situated through the equipment. In Case Of Fire When a fire starts, the way the operator reacts is very important. As soon as the operator is aware of a fire, he should do the four following things: 1. Once the machine is safely stopped, Turn the machine off and set the brake. 2. Quickly actuate the AFFF 150/250/350 Bulk tank system by pulling the safety ring pin on the manual/automatic actuator and strike the red knob. 3. Evacuate the Vehicle 4. Stand by at a safe distance with a fire extinguisher. CAUTION! The system described in this manual is a fire suppression system and is not designed or intended to extinguish all fires, particularly when unusual amounts of combustible materials and ample oxygen supply are present. It is extremely important that supplement firefighting equipment be available in case the system does not totally extinguish a fire. S REV(30/09/2015) Page 3 of 25

4 Actuation Gas Cartridge( P/N:ASEX - V20) The Actuation gas cartridge, ASEX Nitrogen Cylinder - Part No. ASEX - V20 is used in the Advanced Bulk remote actuators, either manual or automatic. The cartridge is a sealed pressure vessel containing nitrogen gas under pressure. When the pin in the remote manual or pneumatic actuator punctures the cartridge seal, the gas flows to the actuator, the gas will follow the actuation line to the pneumatic control head situated on top of the cylinder, when desired pressure is met the piston will open allowing the agent to discharge through a separate discharge hydraulic hose network. Included on the cartridge is a gauge for visual inspections. Part Number:ASEX - V20 Manual Actuators(P/N: ASEX - V21) 2000PSI Nitrogen Bracket - Part No. ASEX - V21 is available for use with the right hand cartridge. Manual actuator(s) should be mounted near the vehicle operator and at a point on the vehicle that can be reached from ground level. Part Number: ASEX - V21 S REV(30/09/2015) Page 4 of 25

5 Manual Actuator Continued.. The manual actuator is designed with a red palm button (P/N: ASEX - V10) which is attached to a cartridge seal piercing pin (P/N:ASEX - V13) and a ring pin (P/N: ASEX - V08) to guard against accidentally piercing the cartridge seal. To initiate agent release, the operator must pull out the ring pin and strike the red palm button. The manual actuator must be located near the operators control station. P/N: ASEX - V13 P/N: ASEX - V08 P/N: ASEX - V10 Safety Relief Valve(P/N: ASEX - V40) A spring loaded pressure valve is used to prevent excessive pressure from building up in the actuation line. The valve is set to relieve at 290PSI(20bar). P/N: ASEX - V40 S REV(30/09/2015) Page 5 of 25

6 Nozzle(P/N: KIDDE-55211) The nozzle is a non-aspirating full cone agent discharge nozzle. A 45º barstock (P/N:KIDDE-55211) allows for a maximum area coverage of 1.5ft(0.5m) per nozzle at a range of 2ft(0.6m) or a diameter of 3ft(0.9m) per nozzle at a range of 4ft(1.2m). Nozzle(s) are available as a single nozzle with blow off cap. Blow off cap P/N: Part Number: KIDDE Nozzle Bracket(P/N: KIDDE-55210) Bracket is constructed of unpainted 1/4 (6.4mm) steel. They contain pre-punctured holes for the nozzle and pre-drilled holes for mounting.(p/n: KIDDE-55210) Part Number: KIDDE S REV(30/09/2015) Page 6 of 25

7 Check Valve(P/N: 53051) The 1/4 check valve (P/N: 53051) is installed in the actuation line between the manual/ automatic actuator and the pneumatic actuator on the connected fire suppression system. This check valve allows actuation pressure to flow to the fire suppression system, but does not allow pressure from other actuation devices to back up into the manual automatic actuator. P/N: S REV(30/09/2015) Page 7 of 25

8 Control Head The operating pressure is set between 150PSI and 2000PSI. The control head works on pressure, when pressure is applied it pushes up the piston inside the control head. Once this piston has reached the desired height, it will allow the pressure from the cylinder to make its way up the dip tube into the discharge line. After a discharge push puncture pin on pneumatic actuator(p/n:asex- V06) to maximum upward position and replace cartridge. CAUTION: Actuator may be under pressure following extinguisher discharge. Always bleed residual pressure through the vent check prior to disassembly. Control Head Continued.. Key (1) - Actuation Hose inlet (2) - Schrader Valve - Part Number : WOR-013 (3) - Bursting Disc - Part Number : (4) - Pressure Gauge- ASEX - V32 (5) - Safety relief valve Pre set to 20bar - Part Number: ASEX-V40 (6) - Pneumatic Control Head - Part Number : ASEX-V04 (7) - Discharge adaptor - Part Number : ASEX-V18 (2) P/N: ASEX-V06 (7) (6) (1) (5) (2) (3) (4) S REV(30/09/2015) Page 8 of 25

9 Design Parameters When used in conjunction with a dry chemical system (twin agent concept), the dry chemical system can be designed as either a standard discharge system or an extended system. An automatic detection system will be required. The twin agent fire suppression system should automatically perform the following functions- Engine shutdown, pressurized hydraulic tank and fuel tank if possible and a fuel shut off. As part of the total fire suppression system package, training for the personal and machine(s) operators must be conducted and documented. A maintenance contract allowing periodic service and maintenance at scheduled intervals should be included. Distribution Hose And Nozzles The distribution piping network is designed to properly distribute the AFFF agent to the foam nozzles. To survive the vibration found on mobile equipment, hose is used to distribute the agent. In the Advanced stored pressure system, hose sizes, maximum and minimum lengths, number of nozzles are all predetermined in the calculation phase. Blow off caps are supplied to be placed over the nozzle to prevent any grease and dirt that may block the nozzle or affect the nozzle spray pattern. Ring Main Ring Main Ring Main 45º Bend Ring Main Agent Tank To Agent Tank(s) S REV(30/09/2015) Page 9 of 25

10 Design Parameters Advanced Stored Bulk Tank 150 Distribution Network When installing the Advanced AFFF 150 bulk stored pressure system, it is important to only use the maximum 1/2 fire suppression hose allowed. The maximum length of 1/2 fire suppression hose calculated and tested for the 150 bulk tank is 77.28m. When installing the system it is important to remember the spacing of your nozzles. If you want an overlapping system, you will need to space your nozzles an equal distance between 700mm and 1.2m, this is a guide only, nozzle placement and aiming should protect the identified hazard inspected. Maximum numbers of nozzles that can be used on the Advanced AFFF 150 bulk system is 20. When installing your Advanced Stored 150 bulk system distribution network, be sure to install a ring main system. This allows for a balanced system. When installing the main discharge line from your tank, it is advised to not extend the maximum distance allowed for the main discharge line, The maximum length allowed for the 150 stored bulk tank is 25m, This is from the tank to the distribution tee. When installing the nozzles, it is important to remember to keep within the guidelines provided. Note: Always make sure that all system hoses are screwed in and tight, all inserts are crimped correctly, hydraulic hoses are secured using the correct form of strapping, heat shrink is used on necessary hydraulic hoses. Tanks are secure, Non-return valves are facing the correct way, cartridges are weighed and correct weight. Actuation Gas Line The Actuation gas line is the line from the manual remote actuators and/ gas cartridges on the automatic detection system to the gas cartridge actuator located on or near the last Advanced AFFF 150 stored bulk tank. The number of actuators that can be actuated from a single actuator cartridge (ASEX - V10), is eight(8). The actuation line can be a maximum of 30.5m. When using more than one (1) actuation cartridge in the system, a 1/4 check valve must be installed to prevent loss of actuation gas from an actuator that may have a cartridge removed. S REV(30/09/2015) Page 10 of 25

11 Advanced 150 Bulk Design Layout Key : N1 - Nozzle 1 N2 - Nozzle 2 (1) - Distribution TEE (2) - Distribution Hose (3) - Pneumatic Control Head (4) - Actuation Hose (5) - Manual Actuator (6) - Continues to remaining nozzles(ring Main) (7) - Continues to remaining nozzles(ring Main) (5) (4) (3) PREMIX AFFF- 9lt Water - 141lt (2) (6) N1 N2 (1) (7) 150 AFFF Bulk Tank The 150 Bulk tank can take a maximum of 20 nozzles. Discharge of the Advanced Bulk system manually is initiated from an automatic or manual actuator. Automatic operation or manually depressing the actuator plunger punctures the seal on the cartridge. The released pressure is transmitted through the actuation line. A safety relief valve in the actuation line prevents too high an actuation pressure build up. When pressure from the actuator manual/automatic, reaches the valve head, it opens the piston situated in the valve. This in essence will allow the pre-pressurized system to discharge through the separate pipe network situated through the equipment. S REV(30/09/2015) Page 11 of 25

12 Advanced Stored Bulk Tank 250 Distribution Network When installing the Advanced AFFF 250 bulk stored pressure system, it is important to only use the maximum 1/2 fire suppression hose allowed. The maximum length of 1/2 fire suppression hose calculated and tested for the 250 bulk tank is 129m. When installing the system it is important to remember the spacing of your nozzles. If you want an overlapping system, you will need to space your nozzles an equal distance between 700mm and 1.2m, this is a guide only, nozzle placement and aiming should protect the identified hazard inspected. Maximum numbers of nozzles that can be used on the Advanced AFFF 250 bulk system is 30. When installing your Advanced Stored 250 bulk system distribution network, be sure to install a ring main system. This allows for a balanced system. When installing the main discharge line from your tank, it is advised to not extend the maximum distance allowed for the main discharge line, The maximum length allowed for the 250 stored bulk tank is 45m, This is from the tank to the distribution tee. When installing the nozzles, it is important to remember to keep within the guidelines provided. Note: Always make sure that all system hoses are screwed in and tight, all inserts are crimped correctly, hydraulic hoses are secured using the correct form of strapping, heat shrink is used on necessary hydraulic hoses. Tanks are secure, Non-return valves are facing the correct way, cartridges are weighed and correct weight. Actuation Gas Line The Actuation gas line is the line from the manual remote actuators and/ gas cartridges on the automatic detection system to the gas cartridge actuator located on or near the last Advanced AFFF 250 stored bulk tank. The number of actuators that can be actuated from a single actuator cartridge (ASEX - V10), is eight(8). The actuation line can be a maximum of 30.5m. When using more than one (1) actuation cartridge in the system, a 1/4 check valve must be installed to prevent loss of actuation gas from an actuator that may have a cartridge removed. S REV(30/09/2015) Page 12 of 25

13 Advanced 250 Bulk Design Layout (5) Key : N1 - Nozzle 1 N2 - Nozzle 2 (1) - Distribution TEE (2) - Distribution Hose (3) - Pneumatic Control Head (4) - Actuation Hose (5) - Manual Actuator (6) - Continues to remaining nozzles(ring Main) (7) - Continues to remaining nozzles(ring Main) (4) (3) PREMIX AFFF- 15lt Water - 235lt (2) (1) N1 (6) N2 250 AFFF Bulk Tank (7) The 250 Bulk tank can take a maximum of 30 nozzles. Discharge of the Advanced Bulk system manually is initiated from an automatic or manual actuator. Automatic operation or manually depressing the actuator plunger punctures the seal on the cartridge. The released pressure is transmitted through the actuation line. A safety relief valve in the actuation line prevents too high an actuation pressure build up. When pressure from the actuator manual/ automatic, reaches the valve head, it opens the piston situated in the valve. This in essence will allow the pre-pressurized system to discharge through the separate pipe network situated through the equipment. S REV(30/09/2015) Page 13 of 25

14 Advanced Stored Bulk Tank 350 Distribution Network When installing the Advanced AFFF 350 bulk stored pressure system, it is important to only use the maximum 1/2 fire suppression hose allowed. The maximum length of 1/2 fire suppression hose calculated and tested for the 350 bulk tank is 170m. When installing the system it is important to remember the spacing of your nozzles. If you want an overlapping system, you will need to space your nozzles an equal distance between 700mm and 1.2m, this is a guide only, nozzle placement and aiming should protect the identified hazard inspected. Maximum numbers of nozzles that can be used on the Advanced AFFF 350 bulk system is 30. When installing your Advanced Stored 150 bulk system distribution network, be sure to install a ring main system. This allows for a balanced system. When installing the main discharge line from your tank, it is advised to not extend the maximum distance allowed for the main discharge line, The maximum length allowed for the 350 stored bulk tank is 64m, This is from the tank to the distribution tee. When installing the nozzles, it is important to remember to keep within the guidelines provided. Note: Always make sure that all system hoses are screwed in and tight, all inserts are crimped correctly, hydraulic hoses are secured using the correct form of strapping, heat shrink is used on necessary hydraulic hoses. Tanks are secure, Non-return valves are facing the correct way, cartridges are weighed and correct weight. Actuation Gas Line The Actuation gas line is the line from the manual remote actuators and/ gas cartridges on the automatic detection system to the gas cartridge actuator located on or near the last Advanced AFFF 350 stored bulk tank. The number of actuators that can be actuated from a single actuator cartridge (ASEX - V10), is Eight(8). The actuation line can be a maximum of 30.5m. When using more than one (1) actuation cartridge in the system, a 1/4 check valve must be installed to prevent loss of actuation gas from an actuator that may have a cartridge removed. S REV(30/09/2015) Page 14 of 25

15 Advanced 350 Bulk Design Layout (5) (4) (3) Key : N1 - Nozzle 1 N2 - Nozzle 2 (1) - Distribution TEE (2) - Distribution Hose (3) - Pneumatic Control Head (4) - Actuation Hose (5) - Manual Actuator (6) - Continues to remaining nozzles(ring Main) (7) - Continues to remaining nozzles(ring Main) (2) PREMIX AFFF- 21lt Water - 329lt N1 (1) (6) N2 (7) 350 AFFF Bulk Tank The 350 Bulk tank can take a maximum of 30 nozzles. Discharge of the Advanced Bulk system manually is initiated from an automatic or manual actuator. Automatic operation or manually depressing the actuator plunger punctures the seal on the cartridge. The released pressure is transmitted through the actuation line. A safety relief valve in the actuation line prevents too high an actuation pressure build up. When pressure from the actuator manual/ automatic, reaches the valve head, it opens the piston situated in the valve. This in essence will allow the pre-pressurized system to discharge through the separate pipe network situated through the equipment. S REV(30/09/2015) Page 15 of 25

16 Recharge Procedure for Stored Pressure 150lt, 250lt & 350lt In the event of a system discharge, please follow the following steps to ensure that a complete and correct recharge is done. NOTE: After recharge make certain all fittings are secure and tight. Check all all hydraulic hoses for any defects, any defects found be sure to replace hydraulic hose, make sure to note hose replaced. Make sure the old service label is removed and a new label installed with correct information shown on label. In this procedure it will be explained how to do a recharge on a general system, when doing your own service you will need to adapt this procedure to the system you currently have installed on site(s). NOTE: These are pressurized vessels, Please take care when recharging the cylinder. Make sure head and fittings are tightly screwed in. Do not over pressure the cylinder. Only trained competent person(s) should be allowed to preform this procedure. Have the correct tools for the job, make sure the tools are in good working order and risk assessments for the current task are up to date, and are relevant for the task you are about to undertake. Be sure to inform people on or around equipment of your current task at hand, be sure to advise them on the risks involved with the task at hand. Under no circumstances are you to: A. Deviate from the recharge Procedure. B. Leave the machine unprotected (unless written permission from senior site personal has been given) C. Alter/Change the system, without any permission or change management documentation. The first priority in recharging is to determine the cause of the system discharge and to have the problem corrected before recharging the fire suppression system. In the event of system discharge, the vehicle must not be returned to service until the system has been recharged. The system must be recharged immediately after use. A fire condition can result in damage to fire suppression system and detection system components, as well as hose, nozzles and possibly other mounting hardware and support. Check all components for possible damage, including hose supports, hose, nozzles and all fitting connections. Remove the nozzles and inspect for damage, corrosion or obstructions. Clean and re-install, making certain they are aimed correctly. All blow off caps must be replaced after a discharge. S REV(30/09/2015) Page 16 of 25

17 Recharge Procedure 1. Remove all additional pressure in the system, this can be achieved by opening the cap on the schrader valve, once cap removed press the schrader valve in to remove all residual pressure. When all pressure is relieved, Continue with recharge procedure. Also once enough pressure is released, SLOWLY open the valve through the pressure vent on side of valve thread. See Image Inspect all hydraulic hoses, make sure all hoses are not damaged, if hoses are damaged, replace the hose. Make sure to note the replaced hose. 3. Check that all hydraulic hoses are secured and not obstructing any other system on equipment. 4. Remove valve head and down tube, check to see if there was a total discharge. 5. Check and clean valve head, Be sure to push the piston head in the valve down. Lubricate all O rings. 6. Open all manual actuators, lubricate all O-rings. Assembly manual actuators, remove safety pin. Strike Knob, if puncture pin drops, insert safety pin and place a lock wire seal. If puncture pin does not drop, replace manual actuator and make note on report on component replaced. Test new manual Actuator, remove safety pin, strike knob. Insert safety pin and place lock wire seal, if found in working order. 7. If the system discharged, the system will need to be blown out. The system can be achieved by connecting the discharge 1/2 hose to an air supply. Before blowing the system out, Make sure all blow off caps are on. After blowing, make sure all blow off caps are off. This will make certain there is no obstruction stuck in the distribution network. 8. Once the blowing procedure is complete, Continue with filling the tank with the required water and foam levels. See table at end. 9. Once desired tank is full to specifications, close the valve hand tight. 10. SET THE NITROGEN REGULATOR TO 1620Kpa. 11. Connect regulator supply hose to Schrader valve situated on the side of the cylinder using the correct hydraulic hose and fittings. 12. Charge the tank to 1620Kpa. 13. Close the the valve on the nitrogen regulator, remove charge line hose from tank. 14. Connect all hoses to the control head. 15. Your system is now Live. 16. Remove all tools and equipment. 17. Make sure all tools and equipment are counted for. 18. Inform operator/control room machine is ready for production. 19. Get service report signed off by competent person. 20. Any additional work done needs to be charged for, information to be supplied to supervisor. 21. Replace actuation cartridge, be sure the discharge pin is fully retracted prior to installing the cartridge. 22. If linear wire is damaged or burnt, replace linear cable and make note of linear wire replaced. 23. Replace used squib. S REV(30/09/2015) Page 17 of 25

18 Specifications Chart When filling the tank(s), please be certain to use the correct measurements for the AFFF to water ratio. Model AFFF Water 150lt 9lt 141lt 250lt 15lt 235lt 350lt 21lt 329lt Image 1 S REV(30/09/2015) Page 18 of 25

19 Maintenance Manual Introduction Maintenance is a thorough check of the system. It is intended to give maximum assurance that the system will operate effectively and safely. It includes a thorough examination and any necessary repair or replacement. It will normally reveal if there is a need for hydrostatic testing of the tank. Maintenance shall be performed quarterly or sooner, depending on operating and/or environmental conditions. The fire suppression system, including alarms, shutdown and associated equipment shall be thoroughly examined and checked for proper operation by an Advanced authorized vehicle system Installer/Technician. With a Service it is important to keep all the correct tools and a service check sheet/book. Upon completion of the service the service sheet must have the following Information : - Machine Model Number - Spares replaced - Signed off by competent person from site. Only trained competent person(s) are allowed to preform this procedure. Have the correct tools for the job, make sure the tools are in good working order and risk assessments for the current task are up to date, and are relevant for the task you are about to undertake. Be sure to inform people on or around equipment of your current task at hand, be sure to advise them on the risks involved with the task at hand. Under no circumstances are you to: A. Deviate from the Service/ Maintenance procedure. B. Leave the machine unprotected (unless written permission from senior site personal has been given) C. Alter/Change the system, without any permission or change management documentation. It is recommended that maintenance be conducted every three (3) months or sooner. All agent tanks must be hydrostatically tested every 5 years, a certificate with valid certification must be supplied with the test. S REV(30/09/2015) Page 19 of 25

20 Quarterly Maintenance To provide maximum assurance that the Advanced AFFF Stored Bulk system will operate effectively and safely: 1. General - Check to see that the hazard(s) has not changed or that additional vehicle equipment has not been added since the original fire suppression system design. 2. To safely disarm the fire suppression/detection system for service, Remove the pneumatic head off the cylinder valve assembly. Once the pneumatic head is removed from the valve assembly, BE SURE TO CLOSE THE TOP OFF WITH THE SHIPPING ASSEMBLY. 3. The general appearance of the fire suppression/detection system components, check for mechanical damage or corrosion and check that components are securely fastened and all hose fittings are tight. 4. Check nameplates and additional remote labels to make certain they are clean, readable and properly attached. 5. When working on the Advanced Stored Bulk AFFF tanks, it is important to remember that the cylinder(s) will be pressurized. When conducting a service follow the steps below to release the pressure in the tank(s). Remove the pneumatic heads from the valve assembly. Make sure to fit the shipping assembly after removing the pneumatic heads. On the valve head assembly there is a schrader valve, Remove pressure by pushing in the schrader valve. 6. Inspect the threads on the valve assembly head and neck ring for any nicks, burrs or cross threading. 7. Check gasket on neck ring of Advanced Stored Bulk AFFF tank for any elasticity, cuts or any other irregularities and replace if necessary. Lightly coat the gasket with a grease. 8. Check the down-tube for any damages, replace if necessary. 9. Check to see that AFFF premix solution is correct. 10. Reinstall valve assembly. 11. With the discharge hose, disconnect from the valve assembly head, blow dry air or nitrogen gas through the agent discharge hose lines at approximately 3bar to make certain the hoses are not blocked with debris or contain moisture. Note: Before performing this procedure, ensure all blow off caps are properly installed. If there are any hoses that do not show pressure discharging from the nozzles, or that show signs of debris at the nozzles. Make certain that any blockages or debris buildup is located and cleaned out of the hose or the hose is replaced. Inspect hose and hose fittings for damage. Replace if necessary. 13. Reinstall any hoses that had to be disconnected. S REV(30/09/2015) Page 20 of 25

21 14. Check that nozzles are tightly secured in their bracket and that the nozzle openings are not obstructed and that the nozzles are properly aimed and have not rotated out of position. 15. Make certain each nozzle has a blow off cap properly installed and check that the caps are clean, pliable and undamaged, and are securely in place with enough room to easily blow off in the event of a discharge. Replace if damaged or missing.note: Blow off caps MUST be replaced annually. 16. Disconnect hydraulic hoses from Actuator(s), and inspect all threaded areas for nicks, burrs and cross threads. 17. Clean actuator(s) as follows: Using two wrenches, one positioned on the swivel nut and one positioned on the bottom portion of the actuator, loosen the swivel nut and remove the top portion of the actuator. Push pin assembly and spring out of the actuator body. Apply a small amount of grease to the puncture pin shaft. Remove the O-Rings from the pin assembly and swivel adaptor. Inspect, clean apply grease and reinstall the O-Rings. Replace if necessary. Apply a small amount of grease to the puncture pin shaft. There is a U-Cup guide inside the actuator body and when the pin is reinstalled into the body, the grease on the shaft will lubricate the U-Cup. Clean the inner surface of the actuator body and, using a small diameter wire, clean the vent hole. MAKE CERTAIN NOT TO SCRATCH THE INNER SURFACE Reinstall spring onto puncture pin shaft and insert actuator body. Push pin down several times to allow grease to coat. When positioned back in body, make certain the tip of the pin is above the detection tubing. 18. Reinstall Swivel adaptor in the correct position for the actuation hose to connect to and wrench tighten the swivel nut. Make certain all detection tubing are properly installed in the actuator. 19. Weigh the gas cartridge. It must be +- 1/2oz. from the weight stamped on the cartridge. weigh with shipping cap removed. 20. Inspect the threaded areas of the actuator for nicks, burrs or cross threading and clean them with a non-metal brush. 21. Blow the actuation hose to make sure the piston move down. S REV(30/09/2015) Page 21 of 25

22 22. Once the above mentioned is in order, proceed with recharging of the Advanced AFFF Stored Bulk system. This can be achieved by, connecting the pneumatic head to the control valve. Connect the 1/2 hydraulic hose to the output outlet. Connect the 1/4 hydraulic hose to the pneumatic actuator. Set nitrogen regulator to 1260Kpa. Connect Advanced Stored Pressure system to regulator, this is done by connecting the hose from the regulator to the schrader valve, situated on the side of the valve assembly. Charge Advanced Stored Pressure AFFF system. Once tank is pressurized, disconnect the recharge line. Turn off regulator. Your system is now LIVE. 23. Record date of maintenance on an permanent record file. 24. AFFF must be replaced Annually. NOTE: Any parts that were replaced within the service must be included on the report.!! S REV(30/09/2015) Page 22 of 25

23 Advanced Fire Suppression 5 Year Maintenance Examination Along with the required Quarterly maintenance steps, at 12 year intervals the following steps are required : 1. The advanced Loss of Pressure Bulk storage tanks must be hydro tested. 2. The AFFF foam pre-mixture must be removed from the tank and discard. Replace with clean, new pre mixture. 3. All actuation hoses must be hydrostatic tested to 1000psi (68.9bar) or replaced Contact Details S REV(30/09/2015) Cape Town Tel: mario@advancedfst.co.za Page 23 of 25

24 S REV(30/09/2015) Page 24 of 25

25 Kimberly(Kenru Fire) Tel: Mokopane (Potgietersrus) Tel: Namibia Tel: Botswana Tel: Mozambique Tel: Zambia Tel: Mauritania Tel: S REV(30/09/2015) Page 25 of 25

A /20/30, LT-A /20/30 VEHICLE SYSTEMS Installation, Recharge, Inspection, and Maintenance Manual

A /20/30, LT-A /20/30 VEHICLE SYSTEMS Installation, Recharge, Inspection, and Maintenance Manual A-101-10/20/30, LT-A-101-10/20/30 VEHICLE SYSTEMS Installation, Recharge, Inspection, and Maintenance Manual 003898 This manual is intended for use with the ANSUL A-101 Vehicle Fire Suppression System.

More information

OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING. Model SGMH 781K. Model SGMH 783K

OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING. Model SGMH 781K. Model SGMH 783K OWNERS SERVICE MANUAL INSTALLATION, OPERATING AND SERVICING Model SGMH 781K ABC (AMMONIUM PHOSPHATE BASE) Model SGMH 783K PK (Potassium Bicarbonate) RECHARGE FIRE EXTINGUISHERS IMMEDIATELY AFTER ANY USE

More information

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve a Installation, Operation, & Maintenance Manual Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve Models AP-3MI & AIP-3MI The information in this manual has

More information

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library

MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library MARINE INERGEN 150-BAR SYSTEMS Component Sheet Library One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2015 Tyco Fire Products LP. / All rights reserved.

More information

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1 Model 1504-50 15 Ton Hand Carry Axle Jack P/N: CJ67D0250-1 Operation and Maintenance Manual with Illustrated Parts List 2222 South Third Street Columbus, Ohio 43207-2402 Phone (614) 443-7492 FAX (614)

More information

Amerex Modular Dry Chemical Vehicle Fire Suppression System

Amerex Modular Dry Chemical Vehicle Fire Suppression System Amerex Modular Dry Chemical Vehicle Fire Suppression System MODELS V13 ABC & V13 PK V25 ABC & V25 PK VH25 ABC & VH25 PK VH30 ABC V50 ABC & V50 PK VS50 ABC & VS50 PK VS75 ABC V250 ABC INSTALLATION, OPERATION,

More information

Maintenance Information

Maintenance Information 16573370 Edition 2 February 2014 Air Grinder 99V Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these

More information

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA 1-1/2 (dn40) July 1, 2011 Deluge Valves 209a DESCRIPTION The Viking Model E-3 1-1/2 Deluge Valve is a quick-opening, differential type flood valve with a rolling diaphragm clapper. The deluge valve is used to control

More information

#10 Setting Tool Assembly Product Family No (10)

#10 Setting Tool Assembly Product Family No (10) BRICO Oil Tools provides a dependable line of Wireline Pressure Setting Tools for the Wireline industry worldwide. Our engineering, high quality and service provides a cost effective alternative. BT#10

More information

FITTING INSTRUCTIONS

FITTING INSTRUCTIONS FITTING INSTRUCTIONS All Zero 360 FIA Systems PLEASE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR SYSTEM Lifeline Fire & Safety Systems Ltd 008 Thank you for purchasing a FIA approved Zero 360 Lifeline

More information

PNEUMATIC SLIDING VALVE

PNEUMATIC SLIDING VALVE INSTALLATION, OPERATION, & #: MM-SV001 6-23-09 Rev. A Page 1 of 8 PNEUMATIC SLIDING VALVE PART NUMBERS (Including, but not inclusive) SV704MSTS, SV714MSTS, SV754MSTS, SV764MSTS, SV774MSTS, SV706MSTS, SV716MSTS,

More information

MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library

MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library MARINE HIGH PRESSURE CARBON DIOXIDE SYSTEMS Component Sheet Library One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2015Tyco Fire Products LP. / All rights

More information

FITTING INSTRUCTIONS

FITTING INSTRUCTIONS FITTING INSTRUCTIONS All Zero ZERO FIA Systems PLEASE READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR SYSTEM Lifeline Fire & Safety Systems Ltd 008 Inst/ZEROzero.5kg/V/Aug08 Thank you for purchasing a

More information

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m

S v S e r i e s F M f i r e e x t i n g u i s h i n g s y s t e m Clean S v S e r i e s F M - 2 0 0 f i r e e x t i n g u i s h i n g s y s t e m Advantages The Sv Series Clean Agent Fire Extinguishing System utilizes FM-200 as the extinguishing medium. FM-200 is a colorless,

More information

AUTOMATIC AIRSPRAY GUN

AUTOMATIC AIRSPRAY GUN INSTRUCTION MANUAL AUTOMATIC AIRSPRAY GUN Manual : 0407 573.011.212 Date : 19/07/04 Supersede : KREMLIN REXSON - Site de Stains : 150, avenue de Stalingrad 93 245 - STAINS CEDEX - FRANCE Téléphone : 33

More information

Welker Heated Instrument Regulator

Welker Heated Instrument Regulator Installation, Operation, and Maintenance Manual Welker Heated Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Automatic Insertion Heated Regulator High Voltage Model IHRA-4SS-220/230 100 or more inch insertion length The information in this manual has been

More information

Hydro-Sync Slide-Out System

Hydro-Sync Slide-Out System Hydro-Sync Slide-Out System SERVICE MANUAL Rev: 08.14.2018 Hydro-Sync Slide-out System Service Manual TABLE OF CONTENTS Safety Information 3 Product Information 3 Operation 4 Extending Slide-Out Room 4

More information

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM, Testing And Adjusting Introduction NOTE: For Specifications with illustrations, make reference to SPECIFICATIONS for 225 EXCAVATOR HYDRAULIC SYSTEM, Form No. SENR7734. If the Specifications are not the

More information

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM INSTALLATION AND MAINTENANCE OF TOP LOADING ARM D TABLE OF CONTENTS 1. INTRODUCTION 04 2. SPECIFICATION OF THE REDLANDS LOADING ARM 04 3. INSTALLING THE LOADING ARM 3.1. Installation Procedures 05 4.

More information

Maintenance Information

Maintenance Information 16573347 Edition 2 February 2014 Air Grinder Series 88H Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED DIAPHRAGM BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to

More information

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives

More information

Industrial Turbo Meters, Sizes 2" through 6"

Industrial Turbo Meters, Sizes 2 through 6 Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product

More information

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA. Q= C v P S 1 of 9 1. DESCRIPTION The Viking Model E-1 Deluge Valve is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction

More information

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE Page 1 of 16 CONTENTS 1.- INTRODUCTION 2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 4.- OPERATION OF A BALL VALVE 5.- PERIODICAL INSPECTION OF THE VALVE AND

More information

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure

Airless Spray Gun INSTRUCTIONS DP psi (345 bar) Maximum Working Pressure INSTRUCTIONS DP-6376 Airless Spray Gun 5000 psi (345 bar) Maximum Working Pressure INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Table of Contents Warnings......................................

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

ARGONITE Fire Protection Systems

ARGONITE Fire Protection Systems GENERAL INFORMATION The Chemetron ARGONITE Fire Protection Systems are clean agent, automatic extinguishing systems using Argonite (IG55) and consisting of four basic components and their associated accessories.

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator

More information

Disassembly and Assembly

Disassembly and Assembly SENR9973-01 September 2007 Disassembly and Assembly 400C Industrial Engine HB (Engine) HD (Engine) HH (Engine) HL (Engine) HM (Engine) HN (Engine) HP (Engine) HR (Engine) Important Safety Information Most

More information

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet) Flow Control 500a DESCRIPTION The Viking 1-1/2 is a quick opening, differential type flood valve with a spring loaded rolling diaphragm clapper. The can be used to facilitate manual or automatic on/off

More information

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

Lifting height 5.5 - 72 with adapters  Height overall 165 Width between columns 122 Drive through 109 Width overall 151. Model Number TP12KC-D Capacity 12,000 lbs. Lifting height 5.5" - 72" with adapters 79.625" Height overall 165" Width between columns 122" Drive through 109" Width overall 151.125" Arm extension 37.5" -

More information

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP PAGE 1 OF 10 OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP EFFICIENT, EASY OPERATION Air operated pump Wide range of pressures and volumes Easy to operate controls Output pressure

More information

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

Welker Automatic Insertion Diffusing Probe Model AIP-3DP Installation, Operation, and Maintenance Manual Welker Automatic Insertion Diffusing Probe Model AIP-3DP The information in this manual has been carefully checked for accuracy and is intended to be used

More information

AN ISO 9001 COMPANY. Barrel Pump BP Operation & Maintenance Guide FF - MM - 01 REV - 0. Sheet 1 of 5

AN ISO 9001 COMPANY. Barrel Pump BP Operation & Maintenance Guide FF - MM - 01 REV - 0. Sheet 1 of 5 AN ISO 9001 COMPANY Barrel Pump BP - 10 Operation & Maintenance Guide Sheet 1 of 5 Barrel Pump BP-10 Operation & Maintenance Guide OPERATION: Barrel Pump is designed to pump light viscous oil like engine

More information

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P) 1 of 9 1. DESCRIPTION The Viking 2 (DN50) is a quick-opening, differential diaphragm, flood valve with one moving part. The deluge valve is used to control water flow in deluge and preaction sprinkler

More information

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS -S INDICATES CYLINDERS ARE IN TANDEM PART NUMBER: 100121 REVISION "A" ECN

More information

ONBOARD AIR SYSTEM FOR ALL VEHICLES APPLICATIONS

ONBOARD AIR SYSTEM FOR ALL VEHICLES APPLICATIONS ONBOARD SYSTEM FOR ALL VEHICLES APPLICATIONS Thank you and congratulations on the purchase of a Pacbrake onboard air system. Please read the manual prior to starting to ensure you can complete the installation

More information

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been

More information

MODEL SCA Installation and Operation Manual Important:

MODEL SCA Installation and Operation Manual Important: MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC

Installation, Operation, and Maintenance Manual. Welker Automatic Insertion Corrosion Coupon Device Model AID-1CC Installation, Operation, and Maintenance Manual Welker Automatic Insertion Corrosion Coupon Device Model The information in this manual has been carefully checked for accuracy and is intended to be used

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

Baumann Mikroseal Control Valve

Baumann Mikroseal Control Valve Instruction Manual 81000 Valve Baumann 81000 Mikroseal Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 3 Installation... 3 Air Piping... 4 Flow Direction...

More information

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6

INSTRUCTION AND REPAIR MANUAL MODELS 341A, 342A AND 344A 6 SECTION 6 ITEM 0 DATED JUNE 1998 SUPERSEDES ITEMS 1, 2, DATED MARCH 1992 INSTRUCTION AND REPAIR MANUAL MODELS 1A, 2A AND A 6 NOTE This repair manual is applicable to pump Models 1A, 2A and A. All photos

More information

CROSBY SERIES BP OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS

CROSBY SERIES BP OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS Before installation these instructions must be read fully and understood cause misalignment of the valve parts. It is recommended that the valves be left in their original shipping containers and that

More information

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L I N S T R U C T I O N M A N U A L M E T E R I N G P U M P S LINC84T-17, 18 & 20 Series Chemical Metering Pump Pneumatic Plunger T A B L E O F C O N T E N T S Contents - 84T-17, -18 & -20 Pump Manual...

More information

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual http://www.torsionx.com Use the RUFNEX Series Ultra-Low Profile Wrenches to install and remove large bolts that have minimal wrench clearance.

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

Warning and Safety Precautions

Warning and Safety Precautions EXPRESS WARRANTY AND DISCLAIMER OF IMPLIED WARRANTIES Lily Corporation unconditionally guarantees its products to be free of defects in material or workmanship and further warrants that, for a period of

More information

PENTECH, INC. BD Spray Gun. Operating Manual Parts Manual May, 2008 Issue 1. Plural Component, Impingement Mixing, Mechanical Purge Spray Gun

PENTECH, INC. BD Spray Gun. Operating Manual Parts Manual May, 2008 Issue 1. Plural Component, Impingement Mixing, Mechanical Purge Spray Gun PENTECH, INC. Operating Manual Parts Manual May, 2008 Issue 1 Plural Component, Impingement Mixing, Mechanical Purge Spray Gun BD Spray Gun PENTECH, INC. 7256 21 st Street East Sarasota, FL 34243 Phone:

More information

Escape Cylinder and Valve

Escape Cylinder and Valve Escape Cylinder and Valve MAINTENANCE AND REPAIR TAL 1601 (L) Rev. 2 MSA 2016 Prnt. Spec. 10000005389 (I) Mat. 10064389 Doc. 10064389 CYLINDER COMPONENTS Item Part No. Description 818159 5 Minute, Aluminum

More information

DT34 and DT54 Series Rotary Sprinklers

DT34 and DT54 Series Rotary Sprinklers DT34 and DT54 Series Rotary Sprinklers Installation & Service Instructions Introduction The DT34 and DT54 series full-circle rotary sprinklers are designed specifically for golf course applications. Manufactured

More information

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company

More information

PISTON ACCUMULATOR. Installation and operation manual Revision

PISTON ACCUMULATOR. Installation and operation manual Revision PISTON ACCUMULATOR Installation and operation manual Revision 2014-4 Content 1.0 INTRODUCTION 4 2.0 GENERAL SAFETY INSTRUCTIONS 5 3.0 WARRANTY 6 3.1 Limitation of the liability 6 4.0 TECHNICAL SPECIFICATIONS,

More information

Max-Upender/Tilt Series Service Manual

Max-Upender/Tilt Series Service Manual Max-Upender/Tilt Series Service Manual LIFT PRODUCTS INC PO BOX 349 ELM GROVE WI 53122 262-521-5720 FAX 262-521-5725 Toll Free 877-543-8776 Model: Max-Upenders & Tilt Tables Manual No. 90185-B REVA 09/08

More information

Backpack Sprayer. Use and Care Manual

Backpack Sprayer. Use and Care Manual Backpack Sprayer Use and Care Manual BACKPACK SPRAYER CAUTION: Read and follow all instructions Do Not Return This Backpack To The Store For Help, Information or Parts, Call : 1-800-311-9903 The Fountainhead

More information

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual www.sameng.co.za (011) 823 4250 Proud Manufacturers of SAMCO Pumps Contents INTRODUCTION 3 LOCATION OF UNIT 3 INSTALLATION

More information

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFO pinch valve is an open frame valve without housing enclosure and fails open on loss of air. The actuator drives

More information

Model Differential Sticking Tester Instruction Manual

Model Differential Sticking Tester Instruction Manual Model 21150 Differential Sticking Tester Instruction Manual Part No. 211510001EA Rev. B TABLE OF CONTENTS 1 General Information 1 2 Safety Considerations 3 3 Timed Filtration Test Procedure 7 4 Fixed

More information

Technical Data Sheet SEVO 1230 Clean Agent Cylinders

Technical Data Sheet SEVO 1230 Clean Agent Cylinders SEVO 1230 Clean Agent Cylinders 140057, 140069, 140079, 140107, 14817, 14813 U lizing 3M TM Novec TM 1230 Fire Protec on Fluid The agent storage cylinder is a steel pressure vessel manufactured, tested

More information

STEERING SYSTEM 6 A POWER STEERING

STEERING SYSTEM 6 A POWER STEERING STEERING SYSTEM 6 A 22147 POWER STEERING Table of Contents Page Specifications............................ 6A-1 Torque Specification................... 6A-1 Special Tools............................ 6A-1

More information

Fisher 3024C Diaphragm Actuator

Fisher 3024C Diaphragm Actuator Instruction Manual 3024C Actuator Fisher 3024C Diaphragm Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 3 Installation... 5 Mounting the Actuator on the Valve...

More information

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS PART NUMBER: 102264 REVISION: "C" DATE: November 2000 Page 1 of 11 1.0 INTRODUCTION 1.1

More information

Cylinder and Valve: AirHawk II Air Mask

Cylinder and Valve: AirHawk II Air Mask Cylinder and Valve: AirHawk II Air Mask MAINTENANCE AND REPAIR MSA 011 (L) Rev. 0 MSA 2010 Prnt. Spec. 10000005389(I) Mat. 10104218 Doc. 10104218 Parts List Cylinder Replacement Kits Item P/N Description

More information

Low Profile Wrenches Operation and Maintenance Manual

Low Profile Wrenches Operation and Maintenance Manual Low Profile Wrenches Operation and Maintenance Manual http://www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install and remove large bolts that have minimal

More information

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

180 Lake Ave North Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER 180 Lake Ave North Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD-E3-009B-MM Rev 2 Dec. 2012 Note: Do not return product to the distributor/dealer

More information

SPECIAL TOOL(S) WARNING: Special Tool(s)

SPECIAL TOOL(S) WARNING: Special Tool(s) Special Tool(s) SPECIAL TOOL(S) WARNING: DO NOT MODIFY THE SYSTEM CONFIGURATION OR COMPONENTS OR REPLACE COMPONENTS WITH COMPONENTS NO SPECIFICALLY DESIGNED FOR USE WITH NATURAL GAS. FORD MOTOR COMPANY

More information

CROSBY SERIES 800 AND 900 OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

CROSBY SERIES 800 AND 900 OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS any and all liability arising out of the same. Any installation, maintenance, adjustment, repair and testing performed on pressure relief valves should be done in accordance with the requirements of all

More information

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico: MicroCoat System Operating Manual MC2 Series MC785, MC785-WF Spray Valves A NORDSON COMPANY US: 8-498-8865 UK: 8 585733 Mexico: 1-8-556-3484 Introduction The MicroCoat System provides precise lubrication

More information

Shock Absorber Rebuild Manual

Shock Absorber Rebuild Manual Shock Absorber Rebuild Manual Model PODIUM RC3 FOX RACING SHOX 130 Hangar Way, Watsonville, CA 95076 PHONE 800.369.7469 FAX 831.768.7026 Email: psservicemw@ridefox.com Website: www.ridefox.com Disclaimer

More information

ReelGreen RG20 Instruction Manual For Operation and Maintenance

ReelGreen RG20 Instruction Manual For Operation and Maintenance ReelGreen RG20 Instruction Manual For Operation and Maintenance BigSprinkler.com 15250 Sunshine Rd. Yukon, OK. 73099 800-373-9325 Introduction Thank you for purchasing a ReelGreen RG20 traveling sprinkler

More information

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)

More information

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TRUCK, FIRE FIGHTING, 4x4, MODEL 1350 PKP/200 AFFF NSN 4210-00-484-5729

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 712 Version BA-2015.10.20 EN Print-No. 300 510 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Collection System. Please read the operator s manual carefully and make sure you understand the instructions before using the machine.

Collection System. Please read the operator s manual carefully and make sure you understand the instructions before using the machine. Collection System 967004601 Please read the operator s manual carefully and make sure you understand the instructions before using the machine. 2012 All rights reserved. Swainsboro, GA. Printed in U.S.A.

More information

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge

Welker Probe Instrument Regulator with Liquid Eliminator Cartridge Installation, Operation, & Maintenance Manual Welker Probe Instrument Regulator with Liquid Eliminator Cartridge Model LEFRD-4SS The information in this manual has been carefully checked for accuracy and

More information

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L I N S T R U C T I O N M A N U A L M E T E R I N G P U M P S LINC84T-10, 11, 12, & 14 Series Chemical Metering Pump Pneumatic Plunger Contents - 84T-10, 11, 12, & 14 Pump Manual... Page General Specifications...

More information

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200} Page 1 of 75 Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200} 943, 953, 963, 973 Loaders Introduction The hydrostatic transmissions used in 943,

More information

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE HWH Online Technical School Lesson 1: Introduction to Hydraulics Chapter 3 - "BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE" (Filename: ML57000-012-CH3.DOC Revised: 22APR16) Click Here

More information

Installation Manual For ISL98, ISL03, ISL07, ISC07

Installation Manual For ISL98, ISL03, ISL07, ISC07 Installation Manual For ISL98, ISL03, ISL07, ISC07 Table of Contents Section 1: Introduction... 3 Housing Identification... 3 Engine Identification... 3 Special Tools... 3 Automatic Transmissions... 3

More information

These instructions are applicable to the following models: ARI 1108 ARI HP1108

These instructions are applicable to the following models: ARI 1108 ARI HP1108 INSPECTION & MAINTENANCE BULLETIN ARI 1108 & HP1108 Safety Relief Valve These instructions are applicable to the following models: ARI 1108 ARI HP1108 Only AAR class F facilities are certified to recondition,

More information

These instructions are applicable to the following models: ARI 1118 ARI 1148

These instructions are applicable to the following models: ARI 1118 ARI 1148 INSPECTION & MAINTENANCE BULLETIN ARI 1118 & 1148 Safety Relief Valve These instructions are applicable to the following models: ARI 1118 ARI 1148 Only AAR class F facilities are certified to recondition,

More information

WALKIE HIGH LIFT HYDRAULIC SYSTEM

WALKIE HIGH LIFT HYDRAULIC SYSTEM WALKIE HIGH LIFT HYDRAULIC SYSTEM W30-40ZA [B453]; W20-30ZR [B455]; W25-30-40ZC [B454] PART NO. 1524251 2000 SRM 1025 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure

More information

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE. IOM Supplement IOMS006 ATI SPLIT COUPLING VALVE STEM CONNECTION Scope of Supplement This supplement is intended to assist those who are involved with the installation, operation and maintenance of ATI

More information

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box

Installation and Service Manual M² Sync Room Slideout System without Room Lock Connectors on Control Box Installation & Service Manual M² Sync Room Slideout System w/o Room Locks: for Slideout Control Box# 1510000143 and 1510000198 Figure 1 01/13 Power Gear #3010002088 Rev. 0C Installation and Service Manual

More information

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR Enidine / Conoflow 105 Commerce Way Westminster, SC 29693 Tel: (864) 647-9521 Fax: (864) 647-7993 WARNING Conoflow s products are designed and manufactured using materials and workmanship required to meet

More information

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed

More information

Operating Procedures for 2 SCH 160 through 10 SCH 120 GripTight Long Radius Elbow Test Plug

Operating Procedures for 2 SCH 160 through 10 SCH 120 GripTight Long Radius Elbow Test Plug EST Group DC2545 10/15 Rev1 01/17 Page 1 of 11 Operating Procedures for 2 SCH 160 through 10 SCH 120 GripTight Long Radius Elbow Test Plug Thank you for choosing to use a GripTight Long Radius Elbow Test

More information

INSTALLATION AND OPERATING

INSTALLATION AND OPERATING Publication T5-704, Rev. 4 Dated: November 1, 2006 INSTALLATION AND OPERATING MANUAL T50-P TURBOTWIN Engine Air Starter AN 99-448 TABLE OF CONTENTS Section Subject Page 1.0 General Information. 1 2.0 Orientation

More information

Series 111 Accumulator Product Information

Series 111 Accumulator Product Information Series 111 Accumulator Product Information l Model 111.11 Model 111.12 011-553-304 B Copyright information Trademark information Contact information Publication information 2000 MTS Systems Corporation.

More information

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016 Levalarm Gold STORAGE AND HANDLING The Reliance Levalarm Gold meets or exceeds all applicable specifications when shipped from

More information

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench - Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench - ProTorc Important Safety Instructions READ ALL INSTRUCTIONS

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL WREN IBT SERIES HYDRAULIC TORQUE WRENCHES IBT SQUARE DRIVE SERIES OPERATION AND MAINTENANCE MANUAL FOR WREN Products: POINT 75, 1IBT, 3IBT, 5IBT, 8IBT, 10IBT, 20IBT, 25IBT, 35IBT, 50IBT SQUARE DRIVE HYDRAULIC

More information

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150) January 13, 2006 Deluge Valves 211 a 1. PRODUCT NAME Viking Model E-1 Deluge Valve 3 (DN80) Available since 1985 4 (DN100) Available since 1985 6 (DN150) Available since 1984 2. MANUFACTURER THE VIKING

More information

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation, and maintenance.

More information

HexPro Series Low Profile Wrenches

HexPro Series Low Profile Wrenches HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install

More information