Self-Priming Horizontal Three and Four Stage Pumps

Size: px
Start display at page:

Download "Self-Priming Horizontal Three and Four Stage Pumps"

Transcription

1 OWNER S MANUAL Self-Priming Horizontal Three and Four Stage Pumps 293 Wright Street, Delavan, WI Phone: Fax: Web Site: BerkeleyPumps.com SSHM-2 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call BE682 (02/27/12)

2 Safety 2 Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product. Save this manual for future reference. This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury! indicates a hazard which, if not avoided, will result in death or serious injury. indicates a hazard which, if not avoided, could result in death or serious injury. indicates a hazard which, if not avoided, could result in minor or moderate injury. NOTICE addresses practices not related to personal injury. Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. Electrical Safety Hazardous voltage. Follow these rules to avoid potential harm: Wire motor for correct voltage. See Electri cal section of this manual and motor nameplate. Ground motor before connecting to power supply. Meet National Electri cal Code, Canadian Elec tri cal Code, and local codes for all wiring. Follow wiring instructions in this manual when connecting motor to power lines. Make workshops childproof; use padlocks and master switches; remove starter keys. Risk of burns. Do not touch an operating motor. Motors can operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling. WARNING Hazardous voltage. Can shock, burn, or cause death. Ground pump before connecting to power supply. WARNING Hazardous pressure! Do not run pump against closed discharge. Release all pressure on system before working on any component. General Safety To avoid heat built-up in pump, over pressure hazard and possible injury, do not use in a pressure tank (domestic water) system. Do not use as a booster pump; pressurized suction may cause pump body to explode. Do not allow pump or piping system to freeze. Freezing can damage pump and pipe, may lead to injury from equipment failure and will void warranty. Pump water only with this pump. Periodically inspect pump and system components. Wear safety glasses at all times when working on pumps. Keep work area clean, uncluttered and properly lighted; store properly all unused tools and equipment. Keep visitors at a safe distance from the work areas. Maximum inlet pressure...30 psi Maximum operating pressure psi Maximum liquid temperature F Maximum motor starts per hour...15

3 Warranty 3 Limited Warranty BERKELEY warrants to the original consumer purchaser ( Purchaser or You ) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Water Systems: Water Systems Products jet pumps, small centrifugal pumps, submersible pumps and related accessories Pro-Source Composite Tanks Pro-Source Steel Pressure Tanks Pro-Source Epoxy-Lined Tanks Sump/Sewage/Effluent Products Agricultural/Commercial: Centrifugals close-coupled motor drive, frame mount, SAE mount, engine drive, VMS, SSCX, SSHM, solids handling, submersible solids handling Submersible Turbines, 6 diameter and larger Warranty Period whichever occurs first: 12 months from date of original installation, or 18 months from date of manufacture 5 years from date of original installation 5 years from date of original installation 3 years from date of original installation 12 months from date of original installation, or 18 months from date of manufacture 12 months from date of original installation, or 24 months from date of manufacture 12 months from date of original installation, or 24 months from date of manufacture Our limited warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void. Your only remedy, and BERKELEY s only duty, is that BERKELEY repair or replace defective products (at BERKELEY s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable. BERKELEY SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, In the U.S.: BERKELEY, 293 Wright St., Delavan, WI In Canada: 269 Trillium Dr., Kitchener, Ontario N2G 4W5

4 Installation 4 Pump Body Dirt and Scale Plug Pump and Pipes Use New Pipe for Best Results. Clean Flow! Figure 1 No Dirt or Scale in Suction Pipe Before you install your pump NOTICE: Well must not be more than 20 depth to water. 1. Long runs and many fittings increase friction and reduce flow. Locate pump as close to well as possible: use as few elbows and fittings as possible. 2. Be sure well is clear of sand. Sand will plug the pump and void the warranty. 3. Protect pump and all piping from freezing. Freezing will split pipe, damage pump and void the warranty. Check locally for frost protection requirements (usually pipe must be 12 below frost line and pump must be insulated). 4. Be sure all pipes and foot valve are clean and in good shape. 5. No air pockets in suction pipe. 6. No leaks in suction pipe. Use PTFE pipe thread sealant tape to seal pipe joints. 7. Unions installed near pump and well will aid in servicing. Leave room to use wrenches. 8 Risk of explosion. Pump body may explode if used as a booster pump. DO NOT use in a booster appli cation. NOTICE: Use the installation method which matches your well type. 9. Install a check valve in the pump suction port. Be sure that the flow arrow points toward the pump. Failure to install a check valve on the inlet side of the pump may allow the pump body to drain between pump cycles, causing dry running, seal or internal failure, and voiding the warranty. No Sags No air leaks In Suction pipe. Use PTFE pipe thread sealant tape or pipe joint compound approved for use on PVC. If air flows water won t Sags Allow Air Pockets If Air Pockets Form, Water Won t Flow. Keep Pipe Straight and Angled up to Pump. Figure 2 Foot Valve Must Work Freely Figure 3 No Air Pockets in Suction Pipe Use PTFE tape. Figure 4 Suction Pipe Must Not Leak

5 Installation 5 Suction pipe 20' (6 m) max. Foot Valve Priming plug Priming tee 10-20' (3-6 m) Standing water level (pump off) Drawdown water level (pump on) At least 5 feet (1.5 m) Figure 5 Cased/Dug Well Installation Check valve Steel drive pipe Drive coupling Driven point Figure 6 Driven Point Installation Gate Valve To Service Priming Plug To Service Check Valve Gate Valve Cased Well Installation 1. Inspect foot valve to be sure it works freely. Inspect strainer to be sure it is clean. 2. Connect foot valve and strainer to the first length of suction pipe and lower pipe into well. Add sections of pipe as needed, using PTFE tape on male threads. Be sure that all suction pipe is leakproof or pump will lose prime and fail to pump. Install foot valve 10 to 20 feet below the lowest level to which water will drop while pump is operating (pumping water level). Your well driller can furnish this in formation. 3. To prevent sand and sediment from entering the pumping system, the foot valve/strainer should be at least 5 feet above the bottom of the well. 4. When the proper depth is reached, install a sanitary well seal over the pipe and in the well casing. Tighten the bolts to seal the casing. 5. When using a foot valve, a priming tee and plug as shown in Figure 5 are recommended. Dug Well Installation Same as cased well installation. Driven Point Installation 1. Connect the suction pipe to the drive point as illustrated in Figure 6. Keep horizontal pipe run as short as possible. Use PTFE pipe thread sealant tape on male pipe threads. Multiple well points may be necessary to provide sufficient water to pump. 2. Install a check valve in horizontal pipe. Flow arrow on check valve must point toward pump. Horizontal Piping From Well To Pump 1. Never install a suction pipe that is smaller than the suction port of the pump. 2. To aid priming on well point installations, install a line check valve as shown in Figure 6. Be sure check valve flow arrow points toward pump. Discharge Pipe Sizes 1. If increasing discharge pipe size, install reducer in pump discharge port. Do not increase pipe size by stages. 2. When the pump is set away from the points of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction. Up to 100 run: Same size as pump discharge port. 100 to 300 run: Increase one pipe size. 300 to 600 run: Increase two pipe sizes. Sprinkling Application This pump is de signed to deliver plenty of water at full sprinkler pres sure. It can pump from a pond, cistern or well points. Pump discharge can be divided to supply two (2) or more sprinkler systems. A suggested multiple dis charge to service is shown in Figure 7. Do not use in a pressure tank or booster pump application. Pump Installation Make sure that all pipe joints in the suction pipe are air tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well. Figure 7 Multiple Discharge

6 Installation 6 Figure 8 Bolt Pump Down Figure 9 Independently Support All Piping Attached to Pump 1 Bolt pump to solid, level foundation. 2. Support all piping connected to the pump. 3. Wrap 1-1/2 to two layers of PTFE tape clockwise (as you face end of pipe) on all male threads being attached to pump. 4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten. NOTICE : Install pump as close to well head as poss ible. Long piping runs and many fittings create friction and reduce flow. NOTICE: For long horizontal pipe runs, install a priming tee between check valve and well head as shown in Figure 6. For driven point installations, install a check valve as shown in Figure 6. Be sure check valve flow arrow points toward pump. Use schedule 80 or iron pipe. See Well Pipe Installation for more information. Wiring Hazardous voltage. Follow these rules to avoid potential harm: Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard. Do not ground to a gas supply line. To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections. Supply voltage must be within ±10% of nameplate voltage. Incorrect voltage can cause fire or damage motor and voids warranty. If in doubt consult a licensed electrician. Use wire size specified in Wiring Chart. If possible, connect pump to a separate branch circuit with no other appliances on it. Wire motor as shown (Figure 12B). If motor nameplate diagram does not match either Figure 12A or 12B, follow nameplate diagram. No air leaks In Suction pipe. If air flows water won t Use PTFE pipe thread sealant tape or pipe joint compound approved for use on PVC. From Well Don t Hit Thread Stops Pump Body Don t Overtighten Hand Tight Plus 1-1/2 Turns With Wrench. Use PTFE tape. Figure 10 Use PTFE pipe thread sealant tape on pipe joints and connections to pump. Figure 11 Don t overtighten.

7 Electrical 7 Green Ground Screw A L2 L1 230 Volts Figure 12A 230V Single Phase Wiring Diagram 3-Phase Low Voltage 4-Brown 5-Orange 6-Black 1-Red LINE 1 7-Purple 2-White LINE 2 8-Gray 3-Blue LINE 3 9-Pink To reverse 3-Phase High Voltage rotation, 4-Brown interchange 7-Purple any two line 5-Orange leads. 8-Gray 6-Black 9-Pink 1-Red LINE 1 2-White LINE 2 3-Blue LINE 3 Figure 12B 3-Phase Wiring Diagram Wiring Chart Recommended Wire and Fuse Sizes Model Motor HP Volts/Hz/Phase Service Factor Amp Connection Diagram for Single-Phase Motors Your motor s terminal board (under the motor end cover) should match the diagram in Figure 12A or 12B. For single-phase motors, follow Figure 12A. For 3-phase motors, follow Figure 12B. If motor does not match this picture, follow the connection diagram on the motor nameplate or in the motor connection box. Hazardous voltage. Can shock, burn, or cause death. Disconnect power to motor before working on pump or motor. Ground motor before con necting to power supply. 1. Install, ground, wire and maintain this pump in accordance with electrical code requirements. Consult your local building inspector for information about codes. 2. Provide a correctly fused disconnect switch for protection while working on motor. Consult local or national electrical codes for switch requirements. 3. Disconnect power before servicing motor or pump. If the disconnect switch is out of sight of pump, lock it open and tag it to prevent unexpected power appli cation. 4. Ground the pump permanently using a wire of the same size as that specified in wiring chart (below). Make ground connection to green grounding term inal under motor canopy marked GRD. or. 5. Connect ground wire to a grounded lead in the service panel or to a metal underground water pipe or well casing at least 10 feet long. Do not connect to plastic pipe or insulated fittings. 6. Protect current carrying and grounding conductors from cuts, grease, heat, oil, and chemicals. 7. Connect current carrying conductors to terminals L1 and L2 under motor canopy (single phase) or in motor connection box (3-phase). When replacing motor, check wiring diagram on motor nameplate against Figures 12A and 12B. If the motor wiring diagram does not match one of the diagrams in Figures 12A and 12B, follow the dia gram on the motor. 8. Motor has automatic internal thermal overload protection. If motor has stopped for unknown reasons, thermal overload may restart it unexpectedly, which could cause injury or property damage. Disconnect power before servicing motor. 9. If this procedure or the wiring diagram is con fusing, consult a licensed electrician. Branch Fuse* Rating Amp (0-30) Distance In Feet(Meters) From Motor To Supply (31-61) (62-91) AWG Wire Size (mm²) (92-122) ( ) B /60/ (3) 12 (3) 10 (5.5) 10 (5.5) 8 (8.4) B /460/60/3 10.2/5.1 15/15 14 (2)/14 (2) 14 (2)/14 (2) 12 (3)/14 (2) 10 (5.5)/14 (2) 10 (5.5)/14 (2) B /60/ (2) 14 (2) 12 (3) 10 (5.5) 10 (5.5) B /460/60/3 9.2/4.6 15/15 14 (2)/14 (2) 14 (2)/14 (2) 12 (3)/14 (2) 10 (5.5)/14 (2) 10 (5.5)/12 (3) * Dual element time delay fuse

8 Operation 8 Figure 13 Remove Priming Plugs Figure 14 Fill Pump Before Starting 3 Figure 15 Do Not Run Pump with Discharge Shut-off. Priming The Pump NOTICE: The term priming refers to the process of pumping all the air out of the system, filling the pump and suction piping with water, and beginning to move water through the pump and out into the system. A selfpriming pump generally will repeat this process without attention once the pump and system are full of water. If the water drains out of the pump (back into the well, for example), then the whole priming process must be repeated before operating the pump again. To make sure that the pump will retain its prime (that is, that the pump and its piping will stay full of water), BE SURE to install a check valve in the pump inlet port with the flow arrow pointing towards the pump. The check valve will prevent water from siphoning out of the pump body and back down into the well, which will keep the pump full and allow it to restart on its own. DO NOT remove the recirculation valve cover (there are spring-loaded parts inside the recirculation valve see Figure 16) when priming or draining the pump. The drain is a hex-head pipe plug underneath the pump body. To drain the pump, remove the hex plug (Ref. No. 17, Repair Parts diagram). Do not disturb the recirculation valve (Ref. No. 19). If the pump or the suction pipe have been drained for any reason, BE SURE to reprime the pump before starting it. NOTICE: NEVER run the pump dry. Running the pump with out water in it will damage the seals, can melt the impellers and diffusers, and voids the warranty. To prevent damage, fill the pump with water before starting. 1. Remove priming plug (Figure 13). 2. Make sure suction and discharge valves and any hoses on discharge side of pump are open. 3. Fill pump and suction pipe with water. 4. Replace priming plug, using PTFE tape on thread; tighten plug. NOTICE: If a priming tee and plug have been provided for a long horizontal run, be sure to fill suction pipe through this tee and replace plug. (Don t forget to PTFE tape the plug.) 5. Start pump: water should be produced in 5 minutes or less, the time depending on depth to water (not more than 20 ) and length of horizontal run (10 of horizontal suction pipe = 1 of vertical lift due to friction losses in the pipe). If no water is produced within 5 minutes, stop pump, release all pressure, remove priming plug, refill and try again. Hazardous pressure and risk of ex plo sion and scalding. If pump is run con ti nu ously at no flow (that is, with discharge shut off or without priming), water may boil in pump and piping system. Under steam pressure, pipes may rupture, blow off of fittings or blow out of pump ports and scald anyone near. To prevent explosion, do the following: A. Be sure discharge (valve, pistol grip hose nozzle, etc.) is open whenever pump is running. B. If pump fails to produce water when attempting to prime, release all pressure, drain pump and refill with cold water after every two attempts. C. When priming, monitor pump and piping tempera ture. If pump or piping begin to feel warm to the touch, shut off pump and allow system to cool off. Release all pressure in system and refill pump and piping with cold water.

9 Maintenance 9 Recirculation Valve: Do not disturb when draining pump! Figure 16 Figure 17 Figure 18 Figure 19 Vent Plug Drain Plug Recirculation Valve Do not disturb! Maintenance If motor is replaced, replace the shaft seal and O-Rings. Keep a seal and O-Rings on hand for future use. Be sure to prime pump before starting. NOTICE: The mechanical shaft seal in the pump is water lubricated and self-adjusting. NOTICE: Drain pump (see Figure 16) when disconnecting from service or when it might freeze. You can fill the pump with RV anti-freeze (propylene glycol) to prevent it from freezing. DO NOT remove the Recirculation Valve to drain the pump (Figure 16). Remove the hex head plug on the bottom of the Pump Suction Body to drain the pump. Pump Disassembly See Repair Parts for Ref. No. references. NOTICE: Do not disturb the recirculation valve (see Figure 16). It is NOT a drain plug! 1. Shut off power to the pump before working on it. 2. Close all suction and discharge valves to isolate the pump before proceeding further. 3. Remove the hex head drain plug (Ref. No. 17) from the suction body and drain the pump. 4. Disconnect the suction line. 5. Remove four capscrews (Ref. No. 18) from the pump (see Figure 17). 6. Pull the pump suction body forward (see Figure 18). Remove the sleeve (Ref. No. 9) by pulling it straight forward. Be careful not to damage the O-rings on the bracket and suction body. 7. Remove the motor canopy, hold the motor shaft with a 7/16 open end wrench, and remove the nut and two washers (Ref. Nos. 14, 13, 12) from the end of the shaft. See Figure Slide the impellers and diffusers (Ref. Nos. 11, 10) off of the shaft (Figure 19). 9. Slide the spacer (Ref. No. 7) off of the shaft, then pull the rotating half of the seal (Ref. No. 6) forward on the shaft and remove it. 10. Block up the motor (so that the shaft will not take the weight of the motor when you loosen the capscrews holding the motor to the bracket), remove four capscrews (Ref. No. 2), and slide the motor and shaft back out of the bracket (see Figure 20). NOTICE: To avoid springing the shaft, be sure that the shaft does not take the weight of the motor as you remove it. Figure 20

10 Maintenance 10 Figure 21 Figure 22 Figure 23 Figure 24 Pipe Correct orientation Figure 25 Cardboard Washer Seal Half Metal ring Slinger Incorrect orientation Seal Removal 1. Follow the instructions under Pump Disassembly, above. 2. Remove the discharge pipe from the bracket (Ref. No. 4). 3. Remove the hold down bolts from the bracket. 4. Turn the bracket motor side up on the bench and use a screwdriver to carefully tap the stationary seal half out of the bracket (see Figure 21). 5. Clean the seal seat cavity in the bracket. Seal Installation 1. Turn the bracket pump side up on the bench. You will need to block it up to do this (See Figure 22). 2. Clean the seal cavity in the bracket. 3. Wet the outer edge of the rubber cup on the ceramic seat with liquid soap. Be sparing! 4. Put a clean cardboard washer on the seal face. With thumb pressure, press the ceramic seal half firmly and squarely into the seal cavity. The polished face of the ceramic seat is up. If the seal will not seat correctly, remove it, placing the seal face up on the bench. Reclean the cavity. The seal should now seat correctly. 5. If the seal does not seat correctly after recleaning the cavity, place a clean cardboard washer over the polished seal face and carefully press it into place using a piece of standard 3/4 pipe as a press. NOTICE: Be sure you do not scratch the seal face. 6. Dispose of the cardboard washer and recheck the seal face to be sure it is free of dirt, foreign particles, scratches and grease. 7. Inspect the shaft to be sure it is free of nicks and scratches. Pump Reassembly 1. Bolt the bracket down to the foundation (see Figure 23). 2. Slide the motor shaft through the seal and bolt up the motor (see Figure 23). Make sure that the slinger is on the shaft between the bracket and the motor flange. Make sure that you don t chip the seal face with the shaft shoulders and that the shaft does not take the weight of the motor at any time. 2. CAREFULLY slide the rotating seal half onto the shaft, seal face first. Make sure that you don t chip the seal face on the shaft shoulders. 3. Follow the seal half with the spacer (Ref. No. 7). Slide the washer up against the seal. 4. Slide a diffuser onto the shaft (open face out) until it seats on the bracket (see Figure 24). Follow the diffuser with an impeller on a fourstage pump or with the stainless steel spacer if a three-stage pump. Engage the molded impeller key in the slot in the shaft. Don t force it! Be sure that the impeller eye, with metal ring, faces out (forward - see Figure 25). 5. Repeat step 4 with the remaining impellers and diffusers. 6. Reinstall the toothed washer, the flat washer, and the impeller nut (in that order Ref. Nos. 12,13,14) onto the motor shaft (see Figure 26). Hold the shaft and tighten the impeller nut to 10 ft.-lbs. torque. 7. Check the sleeve O-Rings; if they show any damage or wear, replace them. Reinstall the sleeve O-Rings (Ref. No. 8) on the bracket and the suction body.

11 Maintenance Troubleshooting 11 Figure 26 Recirculation Valve Do not disturb! Figure Reinstall the sleeve on the bracket and the pump suction body in the sleeve. Be sure that you do not pinch or damage the O-Ring. See Figure Install four capscrews (Ref. No. 18) through the pump head and into the bracket. Tighten the capscrews to 22 ft.-lbs. torque. 10. Reinstall the drain plug and washer (Ref. Nos. 17 and 16) in the suction body. NOTICE: Do not disturb the recirculation valve. 11. Reinstall the suction and discharge piping and open all valves. Check for leaks. 12. Prime the pump according to the instructions on Page 8. Troubleshooting Symptom Possible Cause(s) Corrective Action(s) Disconnect switch is off Be sure switch is on. Fuse is blown or circuit breaker tripped. Replace fuse or reset circuit breaker. Motor will not run Starting switch is defective. DISCONNECT POWER; Replace starting switch. Refer to instructions on wiring. DISCONNECT POWER; check and tighten all wiring. Risk of electrical shock. Capacitor voltage may be hazardous. To Wires at motor are loose, discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short disconnected, or wired incorrectly. capacitor terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician. Motor is wired incorrectly. Refer to instructions on wiring. Motor runs hot and overload kicks off. Check with power company. Install heavier wiring if wire size is too small (See Voltage is too low Electrical / Wiring Chart). 1. Improper priming 1. Re-prime according to instructions. Motor runs but no water is delivered 2. Air leaks 2. Check all connections on suction line, with soapy water or shaving cream. in new installation:* 3. Leaking foot valve or check valve 3. Replace foot valve or check valve. * Stop pump; then check prime before looking for other causes. Unscrew priming plug and see if water is in priming hole. Pump has lost prime in installation already in use: Pump does not deliver water to full capacity. 1. Air leaks 1. Check all connections on suction line and shaft seal. 2. Water level below suction pipe inlet Foot valve or strainer is plugged Impeller is plugged Check valve or foot valve is stuck shut Pipes are frozen Foot valve and/or strainer are buried in sand or mud. Water level is too low for shallow well setup to deliver water. Water level in well is lower than estimated. Steel piping (if used) is corroded or limed, causing excess friction. Piping is too small in size Packed well point 2. Lower suction line into water and re-prime. If receding water level in well exceeds 20 (6.1M), a deep well pump is needed. Clean foot valvye or strainer. Clean impeller. Replace check valve or foot valve. Thaw pipes. Bury pipes below frost line. Heat pit or pump house. Raise foot valve and/or strainer above bottom of water source. Clean foot valve and strainer. Pump will not lift water more than 20 (6.1M). A deep well jet will be needed if depth to water in your well is more than 20 (6.1m). Replace with plastic pipe where possible, otherwise with new steel pipe. Use larger piping. Backflush well point or sink new point.

12 Repair Parts Exploded View 1 ø 3 ø 3 Stage B86073 B Stage B82456 B A Ref. Part Description Qty. B82456 B82639 B86073 B Motor 1 B85740 B86076 B86075 B Socket Head Capscrew 4 U30-104ZP 3 Slinger Bracket 1 M Impeller Repair Kit (Includes Ref. Nos. 6 8 and 10 14) 1 B85604 B Shaft Seal 1 U Spacer 1 121P O-Ring 2 111P Sleeve 1 251A Diffuser 4 101P Impeller 3 or 4 101P A Spacer (3 Stg pump only) 1 M Washer, Flat 1 121P Washer, Toothed 5 M Impeller Nut 1 U36-204SSW 15 Pump Body (Suction) 1 751S Washer 2 121P Pipe Plug 2 171P Capscrew 4 121P Recirculation Valve Complete (Includes O-Ring) 1 ZBR05820

Call DS3 Series. Installation/Operation/Parts For further operating, installation, or maintenance assistance:

Call DS3 Series. Installation/Operation/Parts For further operating, installation, or maintenance assistance: OWNER S MANUAL Self-Priming Centrifugal Pump DS3 Series 3621 0714 ASB Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 888-782-7483 293 WRIGHT STREET, DELAVAN,

More information

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE CORROSION RESISTANT SELF-PRIMING CENTRIFUGAL PUMP MODELS - PD2 SERIES 3/4 HP 1 HP 1-1/2 HP PD2HD-L PD2HE-L PD2HF-L MODELS

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST owner's Manual LTH Series 60 Cycle Self-Priming Centrifugal Pump INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 1 HP 1-1/2 HP 2 HP 2-1/2 HP LTH-1 LTH-1 1 2 LTH-2 LTH-2 1 2 10LTH11C 15LTH11C

More information

Self-Priming Centrifugal Pumps

Self-Priming Centrifugal Pumps OWNER S MANUAL Self-Priming Centrifugal Pumps 293 Wright Street, Delavan, WI 53115 D Series 1362 1094ASBN Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call

More information

Flotec Pumps FP Click here for Pricing/Ordering for Pumps and Parts MOD. FP5230. Installation/Fonctionnement/Pièces

Flotec Pumps FP Click here for Pricing/Ordering for Pumps and Parts MOD. FP5230. Installation/Fonctionnement/Pièces P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Fax: 1-800-526-3757 E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com OWNER S MANUAL Cast Iron Centrifugal Lawn Sprinkler Pump NOTICE

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST MEDIUM HEAD HIGH HEAD MODELS 1 HP 1-1/2 HP 2 HP 2-1/2 HP DMMG-42L DMG-41L DMMG3-42

More information

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS 1 HP 1-1/2 HP 2 HP 2-1/2 HP DMG-41L DMMG-42L MEDIUM HEAD DMG3-41 DMMG3-42

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Horizontal Multi-Stage Jet Pumps HMS-1FL Series MODELS 3/4 HP 1 HP 1-1/2 HP HMSD-1FL HMSE-1FL HMSF-1FL STA-RITE INDUSTRIES 293 Wright

More information

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26 OWNER S MANUAL Engine Driven High Pressure Pump Model B1-1/2XQBS-11 Model B1-1/2XQBS-18 Model B1-1/2XQBS-26 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM PH: 888-237-5353 269 Trillium Drive,

More information

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP MODELS Medium Head Noryl Impellers Medium Head Brass Impellers High Head Noryl Impellers High Head Brass Impellers 1/3 through 2-1/2 H.P.: 115/230 Volt Single

More information

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL

Vertical Jet Pumps. SSJ Series. Call OWNER S MANUAL OWNER S MANUAL Vertical Jet Pumps 293 Wright Street, Delavan, WI 53115 SSJ Series Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-262-728-5551 2005,

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL 60 Cycle CT Series Centrifugal Pump INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST HP MODELS 1/2 CTJ05B CTJ05B3 CTJ05 CTJ053 3/4 CTJ07B CTJ07B3 CTJ07 CTJ073 1 CTJ10B CTJ10B3 CTJ10

More information

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends. Page 1 Selection For Pumping Application Pump End When delivering the required capacity (GPM) to the system piping, the pump must add the amount of Head required by the system at that capacity. The operating

More information

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK OWNER S MANUAL 6 Submersible Motors PENTEK XE-6 232852 DRINKING WATER SYSTEM COMPONENT ANSI/NSF 61-G 3RZE 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.PUMPS.COM PH: 1-866-9 PENTEK 2015 Pentair Ltd. All Rights

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

MS Series. Call Multi-Stage Deep Well Jet Pumps. For further operating, installation, or maintenance assistance:

MS Series. Call Multi-Stage Deep Well Jet Pumps. For further operating, installation, or maintenance assistance: OWNER S MANUAL Multi-Stage Deep Well Jet Pumps 293 Wright Street, Delavan, WI 53115 40 80 MS Series Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-262-728-5551

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

6TSP Series Radial Flow

6TSP Series Radial Flow OWNER S MANUAL Submersible Turbine Pumps 293 Wright Street, Delavan, WI 53115 Phone: 888-237-5353 Fax: 800-321-8793 Web Site: berkeleypumps.com 6TSP Series Radial Flow Installation/Operation/Parts For

More information

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS Models 125M/B, 150M/B and 200M/B ENGLISH: PAGES 2-8 Installation and Service Manual NOTE! To the installer: Please make sure you provide

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNERS MNUL INSTLLTION ND OPERTING INSTRUCTIONS REPIR PRTS LIST Horizontal Multi-Stage Jet Pumps HMS-1FL Series MODELS 3/4 HP 1 HP 1-1/2 HP HMSD-1FL HMSE-1FL HMSF-1FL ST-RITE INDUSTRIES, INC. 293 Wright

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Centrifugal Pump Primer 383 0893 MODEL 6D, HAN-DEE PRIMER IMPORTANT For best possible performance continuous, satisfactory operation,

More information

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1 Pump Installation and Service Manual W/D/V-A1 Submersible Sump Pump W-A1 D-A1 V-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

SHALLOW WELL JET PUMP

SHALLOW WELL JET PUMP SHALLOW WELL JET PUMP MODEL FJ05S 1/2 HP flintandwalling.com ATTACH YOUR RECEIPT HERE Serial Number Purchase Date 1 FW1642 B TABLE OF CONTENTS Product Specifications...2 Safety Information...2 Package

More information

5PNP15H. Call Installation/Operation/Parts For further operating, installation, or maintenance assistance:

5PNP15H. Call Installation/Operation/Parts For further operating, installation, or maintenance assistance: OWNER S MANUAL Shallow Well Water System 5PNP15H 3869 0101 Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call 1-888-782-7483 2014 BE586 (02/28/14) Safety

More information

STAR STOP SHALLOW WELL JET PUMP

STAR STOP SHALLOW WELL JET PUMP SHALLOW WELL JET PUMP MODEL SJ0S / HP STAR starwatersystems.com STOP Questions, problems, missing parts? Before returning to your retailer, call our customer service department at -800-7-0, 7:0 a.m. -

More information

Models 3305P, 3307P, 3310P

Models 3305P, 3307P, 3310P OWNER S MANUAL Convertible Deep Well Jet umps 293 Wright St., Delavan, WI 53115 hone: 1-800-468-7867 1-800-546-7867 Fax: 1-800-390-5351 5301 0206 Models 3305, 3307, 3310 Installation/Operation For further

More information

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English... P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Fax: 1-800-526-3757 E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com OWNER S MANUAL Submersible Waterfall/Utility Pumps 3384 0399

More information

LAWN SPRINKLER, IRRIGATION PUMP

LAWN SPRINKLER, IRRIGATION PUMP LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

More information

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

SHEF30 Submersible Sump/ Effluent Pump

SHEF30 Submersible Sump/ Effluent Pump Installation and Service Manual SHEF30 Submersible Sump/ Effluent Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party

More information

Series FP4100. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

Series FP4100. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, P.O. Box 342, Delavan, WI 53115 Phone: 1-800-365-6832 Fax: 1-800-526-3757 E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com OWNER S MANUAL Shallow Well Jet Pumps/ Tank Systems NOTICE D

More information

SN Series / Série SN / Serie SN HN Series / Série HN / Serie HN

SN Series / Série SN / Serie SN HN Series / Série HN / Serie HN OWNER S MANUAL Shallow Well Jet Pumps NOTICE D UTILISATION Pompes à éjecteur pour puits peu profonds MANUAL DEL PROPIETARIO Bombas tipo Jet para pozos poco profundos 2400 0496 NF SN Series / Série SN /

More information

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation.

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation. OWNER`S MANUAL ONGA 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation. Should the installer or owner be unfamiliar with the correct installation

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter... Installation, Operation & Parts Manual ME45 Submersible Effluent Pump SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

SUBMERSIBLE SWIMMING POOL DRAINER

SUBMERSIBLE SWIMMING POOL DRAINER SUBMERSIBLE SWIMMING POOL DRAINER O W N E R S M A N U A L INSTALLATION, OPERATION & PARTS MODEL PCD-10B Sta-Rite Pool/Spa Group 293 Wright Street, Delavan, WI 53115 Use of electrical appliances around

More information

OWNER S MANUAL CONVERTIBLE JET PUMP

OWNER S MANUAL CONVERTIBLE JET PUMP OWNER S MANUAL Model 64011/64023/64033/ 64026/64036 CONVERTIBLE JET PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800) OWNER S MANUAL Statuary and Pumps P.O. Box 4, Delavan, WI 55 Phone: -800-65-68 Fax: -800-56-757 E-Mail: flotec@flotecpump.com Web Site: http://www.flotecwater.com Water is Our Business NOTICE D UTILISATION

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1 Unit Installation and Service Manual A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

Close Coupled Motor Drive Self Priming Centrifugal Pump

Close Coupled Motor Drive Self Priming Centrifugal Pump 293 Wright Street, Delavan, WI 53115 Phone: 888-782-7483 Fax: 800-426-9446 Web Site: BerkeleyPumps.com OWNER S MANUAL Close Coupled Motor Drive Self Priming Centrifugal Pump B2X, B3T, B4T, B4Z Important

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

GeyserMax-Flow Series

GeyserMax-Flow Series GeyserMax-Flow Series 115V/60Hz Waterfall Pump GM-3900 1/5HP 150W / Discharge 1-1/2 GM-4700 1/3HP 250W / Discharge 2 GM-5400 1/2HP 400W / Discharge 2 GM-6200 3/4HP 750W / Discharge 2 230V/50Hz GM-3800

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

SP40 Submersible Sewage Ejector Pump

SP40 Submersible Sewage Ejector Pump Pump Installation and Service Manual SP40 Submersible Sewage Ejector Pump 6096 1009 NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 100WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps USER S MANUAL FOR F & Q Submersible Sewage Pumps 50WQ Series The F&Q pumps are carefully inspected and tested to ensure operating performance and safety. However, failure to follow the instructions and

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST owner's manual Hydraulic-Motor Frame Mounted Centrifugal Pump Direct Coupling Drive INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 3949 0401 IMPORTANT For best possible performance and continuous,

More information

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2 Pump Installation and Service Manual SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2 NOTE! To the installer: Please make sure you provide this manual to the owner

More information

Submersible Sewage Ejector Pump

Submersible Sewage Ejector Pump SKV40 740 East 9th Street, Ashland, OH 44805 Phone: 1-888-957-8677 Fax: 1-419-281-4087 Web Site: http://www.hydromatic.com Submersible Sewage Ejector Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

MH Series - Horizontal Multistage Pump OWNER'S MANUAL

MH Series - Horizontal Multistage Pump OWNER'S MANUAL MH Series - Horizontal Multistage Pump OWNER'S MANUAL BEFORE YOU START BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. REFER TO PRODUCT DATA PLATE(S) FOR ADDITIONAL OPERATING INSTRUCTIONS

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol.

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

6 and 8 HAIR AND LINT STRAINERS

6 and 8 HAIR AND LINT STRAINERS 6 and 8 HAIR AND LINT STRAINERS O W N E R S M A N U A L INSTALLATION, OPERATION & PARTS MODELS Pkg. 51 6 Cast Iron Pkg. 98 8 Cast Iron Pkg. 56 6 Bronze Pkg. 99 8 Bronze This manual should be furnished

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

Submersible Solids Handling Pumps

Submersible Solids Handling Pumps EC3/EC4/SC4/HT3/HTX3/SC5/SC Series 293 Wright Street Delavan, WI 53115 Submersible Solids Handling Pumps INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS VERTICAL MULTISTAGE PUMPS Single and Three Phase 60 Cycle Record the following information from the motor and pump nameplates for future reference:

More information

Installation Operation Parts

Installation Operation Parts OWNER S MANUAL BATTERY BACKUP SUMP Installation Operation Parts For further operating, installation or maintenance assistance, Call 98-8-05 PRINTED IN U.S.A. M-8 (/9) RULES FOR SAFE INSTALLATION AND OPERATION

More information

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY V6 VERTICAL BOOSTER PUMP OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. C A U T I O N Mechanical shaft seals must not run dry. Fill pump with water before starting

More information

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps INSTALLATION MANUAL Series: 1/12HP, 5000 RPM, 60 Hz ISP No: - 6/09 General Safety Information Before installation, read the following instructions carefully. Failure to follow instruction and Safety information

More information

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM245 RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL SAFETY INSTRUCTIONS TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR

More information

Artesian Owners Manual

Artesian Owners Manual Artesian Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source. OWNER S MANUAL RK2 Systems Pro Pump Energy-Efficient, Self Priming Centrifugal Pumps Important Safety Instructions Please read all instructions completely before you install or operate your new pump. Save

More information

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800) OWNER S MANUAL Plumber s Classic 1/2 HP Cast Iron Submersible Sump Pump 293 Wright St., Delavan, WI 53115 Phone: 1-800-468-7867 Fax: 1-800-390-5351 Web Site: SimerPump.com NOTICE D UTILISATION Pompe de

More information

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump Installation and Service Manual SKV50 Submersible Sewage Ejector NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains

More information

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps Now Includes OSP50AB Parts List NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment

More information

D SERIES CENTRIFUGAL PUMPS WITH TRAP FOR SWIMMING POOL USE

D SERIES CENTRIFUGAL PUMPS WITH TRAP FOR SWIMMING POOL USE D SERIES CENTRIFUGAL PUMPS WITH TRAP FOR SWIMMING POOL USE O W N E R S M A N U A L INSTALLATION, OPERATION & PARTS MODELS Medium Head High Head Medium Head High Head H.P. Phase Models Models Models Models

More information

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

GARDEN HOSE UTILITY PUMP

GARDEN HOSE UTILITY PUMP GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before

More information

MODEL SS INSTALLATION INSTRUCTIONS

MODEL SS INSTALLATION INSTRUCTIONS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

ArtesianPro Owners Manual

ArtesianPro Owners Manual ArtesianPro Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

Submersible Effluent Pump

Submersible Effluent Pump ME45 Submersible Effluent Pump INSTALLATION, OPERATION, & PARTS MANUAL SAFETY INFORMATION Carefully read and follow all safety instructions in this manual or on pump. This is the safety alert symbol. When

More information

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115 Heater Manifold REPLACEMENT INSTRUCTIONS Sta-Rite Pool/Spa Group 293 Wright Street, Delavan, WI 53115 International: 262-728-5551, FAX: 262-728-7550 www.starite.com Union City, TN Delavan, WI Mississauga,

More information

Artesian2 Owners Manual

Artesian2 Owners Manual Artesian2 Owners Manual Energy-Efficient, Self Priming Centrifugal Pumps Discharge Inlet Important Safety Instructions Please read all instructions completely before you install or operate your new pump.

More information

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com JET PUMP INSTALLATION

More information

Material required for drilled well application (indoor use only)

Material required for drilled well application (indoor use only) SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C

More information

StormPro BCV400 Sewage Ejector Pump

StormPro BCV400 Sewage Ejector Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION FW000 009 Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your

More information

Specifications Information and Repair Parts Manual , , , &

Specifications Information and Repair Parts Manual , , , & Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS

INSTALLATION INSTRUCTIONS MODELS S S S S SSN S SSW SSN SPRINKLER PUMPS WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping.

More information

Submersible Solids Handling Pump

Submersible Solids Handling Pump Installation and Operator s Manual Submersible Solids Handling Pump 293 Wright St., Delavan, WI 53115 Phone: 1-800-642-5930 Fax: 1-800-426-9446 Web Site: jungpumpen-us.com 6267 0910 Installation/Operation/Parts

More information

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS Model T033 CONVERTIBLE JET PUMP /HP 900 GPH Suction lift Head of 5 (7.5m) in shallow well mode Professional Series YEAR WARRANTY Suction: /4 Discharge: NPT Maximum pressure: 85 PSI US GPH LPH 5 900 3400

More information

Tri-Clover Manual and Air Actuated Fractional Valves

Tri-Clover Manual and Air Actuated Fractional Valves FVSM-99 Tri-Clover Manual and Air Actuated Fractional Valves Series 650 655 660 CONTENTS Thank you for purchasing an Alfa Laval Product! This manual contains disassembly and assembly instructions, maintenance

More information

Hydraulic Transmission Jack, Telescopic

Hydraulic Transmission Jack, Telescopic Operating Instructions & Parts Manual Hydraulic Transmission Jack, Telescopic Model 4000 400 (Air Operated) Capacity 000 lbs. 000 lbs. Model 4000 Model 400 U.S. Patent No. 6,02,377! This is the safety

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Submersible Grinder Pumps

Submersible Grinder Pumps Installation and Operator s Manual Submersible Grinder Pumps 293 Wright St., Delavan, WI 53115 Phone: 1-800-642-5930 Fax: 1-800-426-9446 Web Site: jungpumpen-us.com Installation/Operation/Parts For further

More information

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B MODELS 25M/B, 50M/B and 200M/B CENTRI-THRIFT CENTRIFUGAL PUMPS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains

More information