END SUCTION CENTRIFUGAL PUMPS

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "END SUCTION CENTRIFUGAL PUMPS"

Transcription

1 OWNERS GUIDE TO INSTALLATION AND OPERATION FW Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump. Be sure to check the following:. Be certain the motor is connected for the correct line voltage being used (check motor nameplate).. Be certain the pump is completely primed before starting. Otherwise damage may occur to the seal. Every pump is tested before leaving the factory, and its performance depends largely on the installation. GENERAL SAFETY INFORMATION. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).. Replace damaged or worn wiring cord immediately.. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces, or chemicals.. Protect the power cable from coming in contact with sharp objects. 5. Be careful when touching the exterior of an operating motor - it may be hot enough to be painful or cause injury.. Make certain that the power source conforms to the requirements of your equipment. 7. Always disconnect power source before performing any work on or near the motor or its connected load. If the power disconnect point is out-of-sight, lock it in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock.. Do not handle the pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power before handling unit for ANY REASON! 9. Unit must be securely and adequately electrically 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved. grounded. This can be accomplished by wiring the unit to a ground metal-clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means.. WARNING: Risk of electric shock. This pump has not been investigated for use in swimming pool areas.. WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. INSPECTION AND STORAGE. Immediately upon receipt of shipment, inspect and check the shipping document and report to the Transportation Company s local agent any damage or shortage. If the unit is received sometime before it can be used, it should be inspected, recrated and stored in a dry location.. Unless otherwise specifically agreed, all capacity, head and efficiency guarantees are based on factory test when handling clear, cold, fresh water at a temperature not over 5 F. LOCATION IMPORTANT: In installations where property damage might result from an inoperative or leaking pump due to power outages, discharge line blockage or any other reason, a back-up system(s) and/or warning system(s) should be used. 9

2 DIMENSIONS in INCHES Figure C000 SERIES Catalog Number Phase Phase HP Motor Frame Size Discharge NPT Suction NPT A B C D E F G J K SINGLE STAGE 500 RPM C JM C 5JM C5 5 JM C5 5 JM TWO STAGE 500 RPM C JM C 5JM C5 5 JM C5 5 JM C7 7-/ JM Dimensions shown above are approximate maximum dimensions for standard pumps equipped with open drip proof motors.. Locate pump as close to the fluid source as greater than that required by the unit. possible. CAUTION: The unit should be placed where the motor and electrical components are protected from the weather and extremes of heat, humidity and below freezing temperatures.. Mount unit in a dry location that is easily accessible for inspection and maintenance. Allow ample clearance around the unit for free air circulation. If a dry location is not available mount it on a foundation well above the wet floor. WARNING: Do not handle the pump with wet hands or when standing in water as fatal electrical shock could occur. Disconnect main power before handling unit for ANY REASON!. Pumps incorporate a discharge port on the pump casing that can be adjusted in 90 increments. If necessary adjust the discharge port to accommodate the specific application. Pump performance will not be affected by the position of the discharge port. SUCTION LIMITATIONS. Units are non self-priming. Normally after being primed the total suction lift of the pump is 5 feet.. Where liquids at or near their boiling points are being handled, the supply must be located above the suction, so that the available NPSH will be 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

3 PIPING. Do not use the pump as support to the piping. The pipe must be independently supported near the pump so that no strains will be transmitted to the unit. Failure to do so will cause premature pump failure and will void the warranty.. Suction and discharge sizes are selected for proper performance of the pumping unit and are not intended to determine the suction and discharge pipe sizes. Pipe sizes must be determined by the user based on the system requirements.. Install both a union and a gate valve (not furnished) on the suction and discharge side of the pump for service convenience. CAUTION: Do not use a globe or other restricting type of valve at the discharge. Globe valves seriously restrict the capacity of the pump.. All joints and connections should have pipe sealing compound (male threads only) applied and drawn up tightly. CAUTION: The entire system must be air and water tight for efficient operation. SUCTION PIPING. Suction piping should be short in length, as direct as possible, and never smaller in diameter than the pump suction opening.. Use galvanized piping, rigid plastic or other suitable pipe that will not collapse under suction.. The suction pipe should slope upward to the pump inlet. A horizontal suction line must have a gradual rise to the pump. Any high point in the pipe will become filled with air and thus prevent proper operation of the pump. When reducing the piping to the suction opening diameter use an eccentric reducer with the eccentric side down to avoid air pockets. Never use a straight taper reducer in a horizontal suction line, as it tends to form an air pocket in the top of the reducer and the pipe. Valves in Suction Piping. If the pump is operating under static suction lift conditions, a foot valve may be installed in the suction line to avoid the necessity of priming each time the pump is started.. When foot valves are used, or where there are other possibilities of liquid hammer, close the discharge valve before shutting down the pump.. The pump must never be throttled by the use of a valve on the suction side of the pump. Valves should be used only to isolate the pump for maintenance purposes, and should always be installed in positions to avoid air pockets. DISCHARGE PIPING. On long horizontal runs it is desirable to maintain as even a grade as possible. Avoid high spots, such as loops, which will collect air and throttle the system or lead to erratic pumping. Valves In Discharge Piping 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.. A check valve and gate valve should be installed in the discharge. The check valve, placed between the pump and the gate valve, protects the pump from excessive pressure, and prevents liquid from running back through the pump in case of power failure. The gate valve is used in priming and starting, and when shutting the pump down. Pressure Gauges. Properly sized pressure gauges can be installed in both the suction and discharge openings in the gauge taps which are provided. The gauges will enable the operator to easily observe the operation of the pump, and also determine if the pump is operating in conformance with the performance curve. If cavitation, vapor binding or other unstable operation should occur, widely fluctuating discharge pressure will be noted. ELECTRICAL CONNECTIONS GROUNDING. To reduce the risk of electric shock. The motor must be securely and adequately grounded to a grounded metal raceway system or by using a separate grounding wire connected to bare metal on the motor frame, or to the grounding screw located inside motor terminal box, or other suitable means. Refer to National Electric Code (NEC Article 50 [Grounding]) for additional information.. All wiring should be preformed by a qualified electrician and in accordance with the National Electric Code, Local Electric Codes and the Occupational Safety and Health Act (OSHA). WARNING: Failure to connect the motor frame to equipment grounding conductor by using green screw may result in serious electrical shock. WIRING CONNECTIONS. This unit is not water proof and is not intended to be used in showers, saunas, or other potentially wet locations. The motor is designed to be used in a clean dry location with access to an adequate supply of cooling air. Ambient temperature around the motor should not exceed F (0 C). For outdoor installations motor must be protected by a cover that does not block airflow to and around the motor. This unit is not weatherproof nor is it able to be submersed in water, or any other liquid.. Motor voltages will vary depending upon the motor horsepower, phase and manufacturer. Refer to the motor nameplate for voltage and electrical data. WARNING: Make certain that the power supply conforms to the electrical specifications of the motor supplies. Failure to do so may cause premature motor failure and will void the warranty.. For proper electrical connections, refer to the connection diagram located on the nameplate or inside the terminal box of the motor. Make sure connections are correct for the voltage being

4 supplied to the motor.. Whenever possible, the pump should be powered from a separate branch circuit of adequate capacity to keep voltage drop to a minimum during starting and running. For longer runs, increase wire size in accordance with the Wire Selection Guide. (See Figures & ) Increaser Gate Valve Check Valve Figure INSTALLATION DIAGRAM Suction Pipe Installed With Gradual Rise To Pump Inlet Eccentric Reducer Center Line Of Pipe Level NOTE: Wire charts are for reference only. Consult local and state codes for approved wire sizes. WARNING: Always disconnect power source before performing any work on or near the motor or its power source. Failure to do so could result in personal injury or fatal electrical shock. Distance From Motor To Fuse Box Meter, or Electrical Outlet 0 ft. 50 ft. 00 ft. 00 ft. 500 ft. 5V 0V 5V 0V 5V 0V 5V 0V 5V 0V. SINGLE PHASE Recommended Copper Wire Size HP -/ HP HP HP 5 HP () Not economical to run at 5V, use 0V. Figure Distance From Motor To Fuse Box Meter, or Electrical Outlet 0 ft. 50 ft. 00 ft. 00 ft. 500 ft. Figure 0V 0V 0V 0V 0V 0V 0V 0V 0V 0V THREE PHASE Recommended Copper Wire Size HP -/ HP HP HP 5 HP 7-/ HP MOTOR PROTECTION WARNING: Never examine, make wiring changes or touch the motor before disconnecting the main electrical supply switch.. Motors may or may not have built-in thermal overload protection depending upon the horsepower size, phase, type and motor manufacturer. Refer to the motor nameplate for overload protection information. It is recommended that a properly sized magnetic or manual starter (both with properly sized heaters) be used with all motors. Install starters following instructions of the starter manufacturer. See Figure 5 & for magnetic starter wiring diagram.. All motors (single and three phase) should be equipped with a correctly fused disconnect switch to provide protection. Consult Local or National Electrical Codes for proper fuse protection based on motor nameplate.. Undersize wiring can cause motor failure (low voltage), frequent cut-out of motor overload protector, television interference and even fire. Make certain the wiring is adequately sized (Figure & ), well insulated and connected to a separate circuit outside the building in case of fire. Magnetic Starter Wiring Diagram - Single Phase Pressure Switch V L T L M W Fused Disconnect Switch Lightning Arrestors T X T Warning: Connect motor leads momentarily for correct rotation Figure 5 Motor # Or Heavier Copper Ground Wire, Connect To ft. Ground Rod Or Well Casing 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

5 Magnetic Starter Wiring Diagram - Three Phase Fused Disconnect Switch L L L W Lightning Arrestors Pressure Switch V M X T T T IL0 T Motor # Or Heavier Copper Ground Wire, Connect To ft. Ground Rod Or Well Casing Figure OPERATION PRIOR TO STARTING. Before the pump is started initially, make the following inspections: Check Rotation - Be sure that the pump operates in the direction indicated by the arrow on the pump casing, as serious damage can result if the pump is operated with incorrect rotation. Rotation is always counterclockwise facing the pump suction. Operating the pump in reverse rotation may cause extensive damage. Check all connections to motor and starting device with wiring diagram. Check voltage, phase and frequency on motor nameplate with line circuit. ALL PUMPS WITH PHASE MOTORS MUST BE INSTALLED WITH A MAGNETIC STARTER WHICH PROVIDES -LEG PROTECTION FOR MOTOR. FAILURE TO USE CORRECT STARTER WILL VOID THE WARRANTY North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

6 PRIMING. Before starting any centrifugal pump it is absolutely necessary that both the casing and suction pipe be completely filled with liquid. This priming can be accomplished by any of the following methods.. When the liquid supply level is above the center line of the pump, it is primed by opening the suction and discharge valves. The inflowing liquid will displace the air and fill the suction line, pump casing, and discharge line up to the level of supply.. Where the pump is operating with suction lift and the suction line is equipped with a foot valve, the system is filled with liquid by filling through the discharge piping. STARTING. Follow the steps below in the order indicated to start pump: Close gate valve in discharge line. Open gate valve in suction line. Turn on power to pump motor.. When pump is operating at full speed, immediately open the discharge gate valve slowly.. If the pump does not prime properly, or loses it PROPERTIES OF WATER Temperature ºF Absolute Vapor Pressure PSI Ft. Water Specific Gravity Altitude (Feet) Barometer Inches Mercury PSIA Atmospheric Pressure (ft. water) Boiling Point ºF North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

7 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Low or no discharge. Incorrect rotation. Refer to wiring diagram. Insufficient inlet pressure or suction head (NPSH Required). Increase inlet pressure by adding more fluid to fluid source. (See Spec s for minimum NPSH Required). Total head too high. Lower discharge head. Leak in suction line. Repair or replace 5. Impeller clogged or damaged 5. Clean or replace. Wrong size piping. Make needed adjustments 7. Casing gasket leaking 7. Replace gasket. Suction or discharge line valves closed. Open 9. Mechanical seal leaking 9. Replace Loss of suction. Insufficient inlet ressure or suction head (NPSH Required). Increase inlet pressure by adding more fluid to fluid source. (See Spec s for minimum NPSH Required). Clogged strainer. Clean or replace Pump vibrates and/or. Mounting plate or foundation not rigid. Reinforce makes excessive noise enough. Foreign material in pump. Clean. Damaged impeller. Replace. Cavitation present. Check suction line for proper size and be sure valve is open. Remove excessive loops in suction line. (See Spec s for minimum NPSH Required) Pump leaks at shaft. Damaged or worn mechanical seal. Replace. Corrosion due to character of liquid. Discontinue pumping liquid and consult factory pumped Pump will not start or. Improperly wired. Refer to wiring diagram run. Blown fuse or open circuit breaker. Replace fuse or close circuit breaker. Loose or broken wiring. Tighten connections and replace broken wiring. Impeller clogged. Clean 5. Motor shorted out 5. Replace Motor problems. Various. Consult qualified electrician. Overloading motor. Too much water. Restrict outlet by closing down valve in discharge line delivery. Liquid heavier and more viscous than. Consult factory water. Seal binding. Replace 5. Rotor binding 5. Repair or replace. Voltage and frequency lower than rating. Reconnect to rated voltage and frequency 7. Defects in motor 7. Repair or replace Pinholes in the casting. Liquid dripsp around seal area but is not seal. Cavitation caused by insufficient inlet pressure or suction head (NPSH Required). Increase inlet pressure by adding a higher level of fluid to source or increasing inlet pressure. (See Spec s for minimum NPSH Required) 7 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved.

8 CENTRIFUGAL PUMP REPAIR PARTS C000 SERIES (For Pricing Refer To Repair Parts Price List) FORM NO. FW SUPERSEDES 07 PAGE -5A REPAIR PARTS 9 5 Qty. Item No. 0 Repair Kit Kit Includes: Part No. & Description Two Stage Seal Assembly 57 O-Ring, Cap Screw 57 O-Ring, Impeller 59 O-Ring, Impeller Gasket 5 7 Single Stage IL000 Product may not be exactly as shown. ITEM HORSEPOWER / STAGE SINGLE PHASE C C5 C C5 THREE PHASE C C5 C C5 C7 DESCRIPTION PART NUMBER Motor Phase Motor Phase Mounting Ring Seal Assembly Key / x 7/ Key / x -/ Impeller O-Ring, Impeller Retainer, Impeller Cap Screw Long O-Ring, Cap Screw Lock Washer / S.S. Gasket Intermediate Stage w/clearance Ring Clearance Ring - Large Clearance Ring - Small Impeller (Front) Retainer, Impeller O-Ring, Impeller Cap Screws -/ Long O-Ring, Cap Screw Lock Washer / S.S. Suction Flange Assembly w/clearance Ring Clearance Ring Pipe Plug / NPT Hex Hd. Cap Screws / x Hex Hd. Cap Screws / x -/ Hex Hd. Cap Screws / x -/ () Standard hardware item () Not shown () () () () () () () () 95 North Oak Street Kendallville, IN 755 Copyright 009. All Rights Reserved () (5) () () () (5) () () () (5) () ()

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS FW000 0 Supersedes 009 READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump.

More information

LAWN SPRINKLER, IRRIGATION PUMP

LAWN SPRINKLER, IRRIGATION PUMP LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Sealless Centrifugal Canned Motor Pumps

Sealless Centrifugal Canned Motor Pumps Installation & Operating Manual Please read this manual carefully before attempting to install, operate or maintain the product described. Failure to comply with the information provided in this manual

More information

MODELS 125M/B, 150M/B and 200M/B

MODELS 125M/B, 150M/B and 200M/B MODELS 25M/B, 50M/B and 200M/B ½, 2, AND 7½ HP SINGLE AND THREE PHASE CENTRI-THRIFT CENTRIFUGAL PUMPS NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual 25IPCC-M 7/08 Edition PC Series C E N T R I F U G A L Congratulations On Your Choice In Purchasing This Webtrol Pump Its Quality is unsurpassed in material and workmanship

More information

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNER S MANUAL 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST MEDIUM HEAD HIGH HEAD MODELS 1 HP 1-1/2 HP 2 HP 2-1/2 HP DMMG-42L DMG-41L DMMG3-42

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

Owners Manual: - Pumps

Owners Manual: - Pumps Owners Manual: - Pumps GENERAL SAFETY RULES 1. The products mentioned in this manual are specially designed for the pre-filtering and re-circulation of water in swimming pools and spas. 2. They are designed

More information

NECO Pumping Systems

NECO Pumping Systems INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems Fuel Oil Transfer System THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED SYSTEM IS OF THE HIGHEST QUALITY AND DESIGN. TO OBTAIN

More information

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual Operating Instructions & Parts Manual EN Hazardous Location Direct-Drive Exhaust Fans Models 10D996 thru 10D999, 10E001 thru 10E007, 10E009 thru 10E020, 32ZN53 and 32ZN54 474904 PLEASE READ AND SAVE THESE

More information

60 Series End-Mount Brake Instructions Standard Housing

60 Series End-Mount Brake Instructions Standard Housing Bulletin No. BK4655 (04/18) 60 Series End-Mount Brake Instructions Standard Housing Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com JET PUMP INSTALLATION

More information

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron

Self-Priming Close-Coupled Centrifugal Pumps In 316 Stainless Steel, Bronze and Cast Iron Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting Electrical wiring

More information

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Pump Curves...2 Pump End Assembly...3 Disassembly...3 Installation...4

More information

Self-Priming Centrifugal Pumps

Self-Priming Centrifugal Pumps OWNER S MANUAL Self-Priming Centrifugal Pumps 293 Wright Street, Delavan, WI 53115 D Series 1362 1094ASBN Installation/Operation/Parts For further operating, installation, or maintenance assistance: Call

More information

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing Bulletin No. BK4775-3 (08/2016) 70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing Read carefully before attempting to assemble, install, operate or

More information

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing

70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing Bulletin No. BK4773-3 (08/2016) 70 Series 8700 End Mount Three Phase Brake Instructions IP56 (NEMA 4) Housing Read carefully before attempting to assemble, install, operate or maintain the product described.

More information

Model &

Model & PumpAgents.com - Click here for Pricing/Ordering Model 31765-0092 & 31765-0094 Dual Sensor Max VSD WATER PRESSURE SYSTEM AUTOMATIC TWO STAGE WATER SYSTEM WITH PUMPGARD STRAINERS IDEAL FOR PLEASURE AND

More information

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing

70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing Bulletin No. BK4772S-3 (6/2017) 70 Series 8700 End Mount Three Phase Brake Instructions IP43 (NEMA 2) Housing Read carefully before attempting to assemble, install, operate or maintain the product described.

More information

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

SLR / SLR-S/N. Instruction Manual. Walrus America Inc SLR / SLR-S/N Instruction Manual Walrus America Inc 1. Installation and Connection 1.1. Pump Installation The pump should be sited in a well ventilated and frost-free position. The distance between pumps-motors

More information

INTRODUCTION Please read this manual

INTRODUCTION Please read this manual 1 INTRODUCTION Please read this manual carefully to learn how to safely install and operate your pump. Failure to do so could result in personal injury or damage to the pump. If there are any questions

More information

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including

More information

Voltmaster Centrifugal Trash Pumps

Voltmaster Centrifugal Trash Pumps Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2

More information

Potable Water Convertible Jet Pumps

Potable Water Convertible Jet Pumps Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. Register your Zoeller Pump

More information

FARMMASTER. JJ & OJ Series

FARMMASTER. JJ & OJ Series OWNER`S MANUAL FARMMASTER JJ & OJ Series Farm Pumps for Stock Watering, Irrigation & Water transfer Should the installer or owner be unfamiliar with the correct installation or operation of this type of

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

STEP-BY-STEP INSTALLATION GUIDE

STEP-BY-STEP INSTALLATION GUIDE Battery Backup System STEP-BY-STEP INSTALLATION GUIDE Operating Instructions & Parts Manual ESP25 Please read and save these instructions. Read carefully before attempting to assemble, install, operate

More information

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY

PUMP PRIMING INSTALLATION CHECK MOTOR ROTATION PUMP START-UP MOTOR REPLACEMENT DISASSEMBLY ELECTRICAL HOOKUP ASSEMBLY V6 VERTICAL BOOSTER PUMP OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. C A U T I O N Mechanical shaft seals must not run dry. Fill pump with water before starting

More information

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding Installation, Operating, Maintenance & Safety Instruction for M PUMPS CM MAG-M SERIES Centrifugal light Mag-Drive pumps (CM MAG-M06/1/2/3/4) This manual presents installation, servicing, troubleshooting,

More information

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps EI-700-005 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to

More information

Six-Inch Submersible Pumps

Six-Inch Submersible Pumps FW1 87 5 thru 5 5 to GPM Supersedes Six-Inch Submersible Pumps Series 6P and 6T High capacity six-inch submersible pumps for commercial, industrial, agricultural, municipal and other deep well, large water

More information

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Horizontal Multi-Stage Jet Pumps HMS-1FL Series MODELS 3/4 HP 1 HP 1-1/2 HP HMSD-1FL HMSE-1FL HMSF-1FL STA-RITE INDUSTRIES 293 Wright

More information

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS OWNER S MANUAL Model: PFUPPP2528251M10 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump ISP No: PFUPPP25-8/01/15 General Safety Information Before installation, read the following instructions carefully.

More information

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation: Installation Vertical Pump: Gusher vertical end suction pumps with integral shaft is easily installed and put into service. With the one piece shaft design there is no couplings to align, no shims or no

More information

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , , POWERLINE XP I Swimming Pool Pump (Light Oak color model) 3 FT CORD UL/NEC Models 0-1295-206, 0-1296-206, 0-1297-206, 0-1298-206 25 FT CORD w/gfci UL Models 0-1295-200, 0-1296-200, 0-1297-200, 0-1298-200

More information

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD Models , , , FT CORD W/GFCI Models , , , POWERLINE XP II Swimming Pool Pump (Light Oak color model) With Automatic Timer 3 FT CORD Models 0-1395-226, 0-1396-226, 0-1397-226, 0-1398-226 25 FT CORD W/GFCI Models 0-1395-220, 0-1396-220, 0-1397-220,

More information

1750 RPM Centrifugal Pumps

1750 RPM Centrifugal Pumps Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery Table 6-1. and solutions with pump operations No Fluid Delivery Fluid level in the reservoir is low. Oil intake pipe or inlet filter is plugged. Air leak in the inlet line prevents priming or causes noise

More information

Operation and Maintenance Manual Magnetic Drive Sealless Pumps MAXP SERIES

Operation and Maintenance Manual Magnetic Drive Sealless Pumps MAXP SERIES Operation and Maintenance Manual Magnetic Drive Sealless Pumps MAXP SERIES Magnatex Pumps, Inc. 3575 West 12th Street Houston, TX 77008 Toll Free: 866.MAG.PUMP Phone:713.972.8666 Fax:713.972.8665 www.magnatexpumps.com

More information

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain) Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain) Pre-Installation 1. Choose a location that is easily accessible for pump servicing. Ensure adequate electrical service is available.

More information

Series Base mounted pump. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions Series 4030 Installation and File No: 40.80 Date: june 25, 2015 Supersedes: 40.80 Date: october 10, 2009 contents General 4 Inspection 4 Installation - Series 4030 base mounted Pump 4 1.0 Location 4 2.0

More information

1329R Small AC Motors

1329R Small AC Motors Installation and Operation Manual 1329R Small AC Motors 1/3 through 3 HP 56-W180T 2 1329R Small AC Motors Installation and Operation Unpacking Unpack motor carefully and inspect for possible damage during

More information

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP TM 42371 Avenida Alvarado Temecula, CA 92590 TOLL FREE (800) 454-2725 TEL (951) 296-3480 FAX (951) 296-3490 www.aquauv.com Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP Sunami Warranty

More information

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions

Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions Users Manual Professional Series Direct Drive Pump.25-2 GPM Series Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232

More information

Pump Installation & Service Manual

Pump Installation & Service Manual unc S entric TM Pump Installation & Service Manual Please record your MODEL # SERIAL # and for your application: Volts Amps Thank you for purchasing the Dankoff SunCentric water pump. This pump has been

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS OWNER S MANUAL FLO-MASTER XP2 SERIES PUMPS IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

More information

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

3 & 4 Cast Iron Self-Priming Centrifugal Pump Instruction Manual 12 3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual 333 & 444 Series Read these instructions and the instructions covering operation of the pump drive unit. Do not operate the gas engine

More information

SERIES FE MAGNETIC COUPLED PUMPS

SERIES FE MAGNETIC COUPLED PUMPS SERIES FE MAGNETIC COUPLED PUMPS Refer to Bulletin P-518 O-2804 TABLE OF CONTENTS Description Page Number Important Information...3 Chemical Reaction Disclaimer...3 Safety Precautions...3 Installation/Operation

More information

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual SAVE THESE INSTRUCTIONS M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual TABLE OF CONTENTS General Information...2 Safety Instructions...2 Installation...2

More information

Standard Power Units Start-Up and Maintenance

Standard Power Units Start-Up and Maintenance Standard Power Units Start-Up and Maintenance Value-Pak System-Pak System Pak-Plus Low-Pak System-Center System-L System-Overhead Table of Contents General Information....................................................................

More information

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This

More information

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications. MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL 2 HP Grinder Pump for Residential Applications. NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment

More information

OPERATING INSTRUCTIONS ZDX 1/12CS

OPERATING INSTRUCTIONS ZDX 1/12CS OPERATING INSTRUCTIONS ZDX 1/12CS www. sethco. com info@sethco.com INDEX Warranty 2 Safety Rules 3 Operating Instructio ns 4 General Description 4 Pre-installation 4 Pump Installation 4 Piping the Pump

More information

Diaphragm Pumps. 335 Series and 336 Series DESCRIPTION

Diaphragm Pumps. 335 Series and 336 Series DESCRIPTION Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models

Close-Coupled Centrifugal Pumps 316 Stainless Steel, Bronze and Cast Iron Models 316 Stainless Steel, Bronze Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain

More information

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation.

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation. OWNER`S MANUAL ONGA 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation. Should the installer or owner be unfamiliar with the correct installation

More information

Portable Electric/Gas Compressor Operating Instructions

Portable Electric/Gas Compressor Operating Instructions Portable Electric/Gas Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 TABLE OF CONTENTS Safety

More information

S200-G Series Centrifugal Fire Pumps Operation and Maintenance Instructions

S200-G Series Centrifugal Fire Pumps Operation and Maintenance Instructions by Waterous S200-G Series Centrifugal Fire Pumps Operation and Maintenance Instructions Table of Contents IL3771 Read through the safety information and operating instructions carefully before using your

More information

4 - Way Control 4 - Way Control 4 - Way Control with lock

4 - Way Control 4 - Way Control 4 - Way Control with lock INSTALLATION / OPERATION / MAINTENANCE 1. DESCRIPTION MODEL 0-02 (Full Internal Port) Powertrol Valve This manual contains information for installation, operation and maintenance of the Cla-Val Co. 0-02

More information

TYPE PC Propeller Condensate Pumps

TYPE PC Propeller Condensate Pumps SHIPPENSBURG PUMP CO. INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PH 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 103 Revised 8/17 TYPE PC Propeller Condensate Pumps with Cast Iron Receivers

More information

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2. Instruction Sheet 1/2 HP Portable Electric Pumps L2062 Rev. F 02/12 Index: English:...................................... 1-7 Français:.................................... 8-14 Deutsch:...................................

More information

NSR PUMPS Installation, Operation and Maintenance Manual

NSR PUMPS Installation, Operation and Maintenance Manual NSR PUMPS Installation, Operation and Maintenance Manual SAM Engineering (Pty) Ltd. 24 Duncan Road, Lilianton, Boksburg, South Africa Tel: +27 (0) 11 823-4250 Fax: +27 (0) 11 823-4943 Email: pumps@sameng.co.za

More information

Pumps and Maintenance

Pumps and Maintenance Pumps and Maintenance Questions 1) Where would you find information on when to lubricate a pump? 2) What problems can develop if too much grease is used in lubricating an electric motor? 3) Why should

More information

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 4558-153-E75 4558-153-E75 APPLICATION: Multi-fixture Marine fresh water system installation.

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL INSTALLATION, OPERATION & MAINTENANCE MANUAL XP-SK SERIES - (PUMP END ONLY) EXPLOSION PROOF SUBMERSIBLE SHREDDER PUMPS (CLASS 1, DIVISION 1, GROUPS C&D): FM APPROVED Three Phase 208V, 230V, 460V & 575V

More information

IN-LINE HYDRAULIC FLOW TESTER

IN-LINE HYDRAULIC FLOW TESTER SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031

More information

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS Model Models 4 & AURORA 0 SERIES SINGLE STAGE TURBINE TYPE PUMPS WWW.AURORAPUMP.COM AURORA 0 SERIES Single Stage Turbine Type Pumps Capacities to 0 G.P.M. Heads to 700 Ft. Temperatures to F A Pioneer in

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual Model: 5010 Hydraulic Power Unit 05/2004 - Rev. 01 Includes Illustrated Parts Lists 1740 Eber Rd Tronair, Inc. Phone: (419) 866-6301 Holland, OH 43528-9794 www.tronair.com 800-426-6301

More information

Diaphragm Pumps. 335 Series and 336 Series DESCRIPTION

Diaphragm Pumps. 335 Series and 336 Series DESCRIPTION Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

50 to 250 GPM Submersible Pumps For Six-Inch Wells. 325 & 400 GPM Submersible Pumps For Eight-Inch Wells

50 to 250 GPM Submersible Pumps For Six-Inch Wells. 325 & 400 GPM Submersible Pumps For Eight-Inch Wells FW5 39B Supersedes 39 5 to 25 GPM Submersible Pumps For Six-Inch Wells & GPM Submersible Pumps For Eight-Inch Wells Series 6P, 6T and 8T High capacity six or eight inch submersible pumps for commercial,

More information

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS I. OPERATION & DESCRIPTION The Air / Hydraulic Injection Gun is a high-pressure tool that should be used with caution and according to these instructions. IMPORTANT: The Gun is 0,000 psi rated. Do not

More information

SUBMERSIBLE MINI-PUMP

SUBMERSIBLE MINI-PUMP SUBMERSIBLE MINI-PUMP Model 41287 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from

More information

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306)

Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306) INDUSTRIES LIMITED Installation, Operation & Maintenance Instructions for MF Series Solution Feeders Axiom Industries Ltd. 2615 Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) 651-1815 Fax: (306) 242-3373

More information

MAINTENANCE GUIDELINES FOR NIBCO ¼ THROUGH 3 CLASS 125, 150, 200 & 300 BRONZE SWING CHECK VALVES FIGURE NUMBERS

MAINTENANCE GUIDELINES FOR NIBCO ¼ THROUGH 3 CLASS 125, 150, 200 & 300 BRONZE SWING CHECK VALVES FIGURE NUMBERS MAINTENANCE GUIDELINES FOR NIBCO ¼ THROUGH 3 CLASS 125, 150, 200 & 300 BRONZE SWING CHECK VALVES FIGURE NUMBERS T-413-B, Y, W S-413, B, Y, W T-433, B, Y, W S-433-B, Y T-453-B, Y T-473-B, Y S-473-B, Y T-473-B,

More information

WARNING SPECIFICATIONS MODEL # A 1-1/2 TON TRANSMISSION JACK. Manufactured to comply with the ASME PASE-2014 Safety Standard.

WARNING SPECIFICATIONS MODEL # A 1-1/2 TON TRANSMISSION JACK. Manufactured to comply with the ASME PASE-2014 Safety Standard. MODEL # 791-7180 A 1-1/2 TON TRANSMISSION JACK BEFORE USING THIS DEVICE, READ THIS MANUAL COMPLETELY AND THOROUGHLY, UNDERSTAND ITS OPERATING PROCEDURES, SAFETY S AND MAINTENANCE REQUIREMENTS. It is the

More information

REPAIR SEALS AND OPTIONS

REPAIR SEALS AND OPTIONS Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A WATTS INDUSTRIES, INC. Technical Data SD 4512A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 4512A/9806 T124/T134 PILOT FRONT VIEW 2 1 /16 F 5 7 /8 2 3

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified TPH Series MULTISTGE CENTRIFUGL PUMP Instruction Manual ISO 9001 Certified Walrus merica Inc 234867 EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. ddress: No. 83-14, Dapiantou, Sanjhih

More information

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE SUBMERSIBLE PUMP HSE RANGE OPERATION & MAINTENANCE INSTRUCTIONS 0707 SPECIFICATIONS HSE300* HSE360* Model No. HSE130* HSE200A HSE300A HSE360A HSEC400* HSE301A HSE361A Outlet Dia. (mm/inches) 32/1-1/4 38/1-1/2

More information

Electric Vibrators. Models. Operating Instructions. Single and Three Phase

Electric Vibrators. Models. Operating Instructions.  Single and Three Phase Operating Instructions Electric Vibrators Models Single and Three Phase QT-80 DEG-6 QT-60 DEG-45 QT-50 DEG-90 QT-500 DEG-0 QT-000 DEG-50 DEG-50 DEG-5000 DEG-5 www.globalmanufacturing.com Global Manufacturing

More information

PT-516 Pumping Trap Installation and Maintenance

PT-516 Pumping Trap Installation and Maintenance PT-516 Pumping Trap Installation and Maintenance IB-104-B This bulletin should be used by experienced personnel as a guide to the installation and maintenance of the PT-516 Pumping Trap or Pumping Trap

More information

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX Installation Manual 5672000E Omnivore Grinder Pump Retrofit Unit FOR E-ONE* GP200, GP2000 AND EXTREME SERIES Models to replace GP200 and GP2000: LSG202-RE 2Hp, 208/230V, 1 phase, Automatic LSGX202-RE 2Hp,

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual L-Series Vacuum Pumps Models L/H400C - L/H630C INSTALLATION & OPERATING MANUAL L/H-SERIES SINGLE STAGE ROTARY VANE VACUUM PUMPS L/H400C-L/H630C Please read the manual

More information

jegs.com. Installation Instructions for Ton Aluminum Floor Jack

jegs.com. Installation Instructions for Ton Aluminum Floor Jack Installation Instructions for 80077 3-Ton Aluminum Floor Jack Contents: Specifications Warning Information Setup and Operating Instructions Preventive Maintenance and Troubleshooting Hydraulic Maintenance

More information

Rev: Flow Max 115V AC Fluid Pump

Rev: Flow Max 115V AC Fluid Pump Flow Max 115V AC Fluid Pump by Duraself Installation and Owner s Manual (For Aftermarket Applications) Table of Contents Introduction... 2 Parts List... 2 Resources Required... 3 Installation... 3 General

More information

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions

S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions S200-P Series Centrifugal Fire Pumps Operation and Maintenance Instructions Table of Contents Read through the safety information and operating instructions carefully before using your S200-P Series Fire

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

HGS STAINLESS STEEL FLUID REGULATORS

HGS STAINLESS STEEL FLUID REGULATORS Service Bulletin SB-6-403-L Replaces SB-6-403-K HGS STAINLESS STEEL FLUID REGULATORS IMPORTANT: Read and fol low all instructions and safety precautions before using this equipment. Retain for future reference.

More information

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS TECHNICAL BROCHURE B36/3742 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS FEATURES Compact Design: Close coupled, space saving design provides easy installation. Flexible couplings and bedplates

More information

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET OEM: AFTERMARKET: 158-16-A75 158-16-E75 APPLICATION: Multi-fixture Marine fresh water pump installation. This pump

More information

Multi-stage Immersion Type

Multi-stage Immersion Type Coolant Pump Instruction Manual Multi-stage Immersion Type VKA/VKC Series WARNING Do not hold the strainer (wire net) of the pump point at the handling of this product. Doing so may cause the strainer

More information

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation.

Instruction Manual PN-Z PACKED PLUNGER PUMP. This Manual should be made available to person responsible for installation, maintenance and operation. MILTON ROY INDIA (P) LTD Metering Pumps Instruction Manual PN-Z PACKED PLUNGER PUMP This Manual should be made available to person responsible for installation, maintenance and operation. PUMP MODEL: SERIAL

More information

C T h e A d va n t a g e

C T h e A d va n t a g e C The Advantage TABLE OF CONTENTS Introduction...1 Product Numbering System...1 Safety...2 Receiving and Inspection...2 Installation...2 Electrical...3 Parts Identification...7 Lubrication...9 Start-up...10

More information

TC Series Cooling Systems

TC Series Cooling Systems TC Series Cooling Systems Table of Contents Table of Contents...1 List of Figures...1 Safety...2 Introduction...2 General Specifications...2 Types of Coolant...2 Routine Maintenance...2 Surge Tank Coolant

More information

Priming Systems Installation Instructions

Priming Systems Installation Instructions Priming Systems Installation Instructions System Components: Single Priming Pump: Single VAP Valve Systems: Control Panel Activated... 2 Auto Prime (Pressure Switch) Activated... 3 Multiple VAP Valve Systems...

More information