Owner s Manual. Powered by. Models: VH200-F10, VH410-F R_RevG

Size: px
Start display at page:

Download "Owner s Manual. Powered by. Models: VH200-F10, VH410-F R_RevG"

Transcription

1 Owner s Manual Models: VH00-F0, VH40-F0 Powered by 45 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) tf. (+) (US and Canada only) t. (+3) (Europe only) f. (+) info@viqua.com R_RevG

2 Congratulations on the purchase of your ultraviolet (UV) water disinfection system! This system uses the most advanced UV technology on the market and is designed to provide you with years of trouble free operation with minimal maintenance required to protect your drinking water from microbiological contaminants. To ensure ongoing disinfection of your water, UV lamps need to be replaced annually with VIQUA factory-supplied replacements. VIQUA lamps are the result of extensive development resulting in a highly efficient disinfection platform with extremely stable UV output over the entire 9000 hour lifetime. Its success has led to a proliferation of nongenuine copies in the market. The UV lamp is the heart of the disinfection system, and there should be no compromise when it's time for a replacement. Why should you insist on genuine factory supplied VIQUA replacement lamps? Use of widely available, non-genuine, replacement lamps has been shown to damage the control module of VIQUA UV disinfection equipment. An increasing number of calls to VIQUA Technical Support are connected with nongenuine lamps being used (unknowingly) as replacements. Damage arising from the use of non-genuine lamps poses a safety risk and is not covered by equipment warranty. Unless the UV equipment is equipped with a UV sensor (monitor), it is not possible to verify the UV (invisible) output of replacement lamps. Similar appearance to the original lamp and the presence of (visible) blue light does not mean equivalent disinfection performance. VIQUA replacement lamps undergo rigorous performance testing and strict quality control processes to ensure that the safety and performance certifications of the original equipment are not compromised. So, you can see that it's simply not worth the risk! Insist on genuine VIQUA replacement lamps.

3 Safety Information Section Safety Information These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment. Make sure that the protection provided by this equipment is not impaired. DO NOT use or install this equipment in any manner other than that specified in the installation manual.. Potential Hazards: Hg Read all labels and tags attached to the system. Personal injury or damage to the system could occur if not observed. Waste electrical and electronic equipment (WEEE). This symbol indicates that you should not discard wasted electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. This symbol indicates there is Mercury present. This is the safety alert symbol. Obey all safety messages that follow this symbol to avoid potential injury. When on the equipment, refer to the Operational and Maintenance manual for additional safety information. This symbol indicates a risk of electrical shock and/or electrocution exists. This symbol indicates not to store any combustible or flammable material close to the system. This symbol indicates that the contents of the transport package are fragile and the package should be handled with care. This symbol indicates safety glasses with side protection is required for protection against UV exposure. This symbol indicates gloves must be worn. This symbol indicates the marked equipment may contain a component that can eject forcibly. Obey all procedures to safely depressurize. This symbol indicates safety boots must be worn. This symbol indicates the system is under pressure. This symbol indicates the operator must read all available documentation to perform required procedures. UV This symbol indicates there is a potential UV hazard. Proper protection must be worn. Cu This symbol indicates the plumber must use copper piping. This symbol indicates the marked item could be hot and should not be touched without care. This symbol indicates that the system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI). This symbol indicates there is a potential for VERY hot water when flow is started. Warning: This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.. Safety Precautions: DANGER Failure to follow these instructions will result in serious injury or death. Electric Shock: To avoid possible electric shock, special care should be taken since water is present near the electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, DO NOT attempt repairs yourself, refer to an authorized service facility. GROUNDING: This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electrical shock. This system is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Improper connection of the equipment-grounding conductor can result in a risk of electrocution. Check with a qualified electrician or service personnel if you are in doubt as to whether the outlet is properly grounded. DO NOT modify the plug provided with this system if it does not fit in the outlet, have a proper outlet installed by a qualified electrician. DO NOT use any type of adapter with this system. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION: To comply with the National Electrical Code (NFPA 70) and to provide additional protection from the risk of electric shock, this system should only be connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI) or to a residual current device (RCD) having a rated residual operating current not exceeding 30 ma. Inspect operation of GFCI as per manufacturer s suggested maintenance schedule. DO NOT operate the disinfection system if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or damaged in any manner. DO NOT use this disinfection system for other than intended use (potable water applications). The use of attachments not recommended or sold by the manufacturer / distributor may cause an unsafe condition. DO NOT install this disinfection system where it will be exposed to the weather or to temperatures below freezing. DO NOT store this disinfection system where it will be exposed to the weather. DO NOT store this disinfection system where it will be exposed to temperatures below freezing unless all water has been drained from it and the water supply has been disconnected. 3

4 Safety Information WARNING During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 C) and potentially lead to scalding. It is recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system. This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin. Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void the manufacturer's warranty. Hg CAUTION Failure to follow these instructions could result in minor or moderate injury. Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the controller or lamp connector. Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 0" of copper pipe on the outlet of your UV chamber. Hg EXPOSURE: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste. NOTICE The UV lamp inside the disinfection system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp annually. The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, are also not to handle the UV system unless they have been given supervision or instruction. This system is intended to be permanently connected to the water lines. This system is not intended to be used in or above water or outdoors or used in swimming pools when persons are in the pool. EXTENSION CORDS: If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use damaged extension cords. Examine extension cord before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always grasp the plug and pull to disconnect. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. SYSTEM PROTECTION: To protect your Controller, a UL449 certified (or equivalent) transient voltage surge suppressor is strongly recommended. The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title, Chapter, Subchapter J, Radiological Health. Read and understand the Owner s Manual before operating and performing any maintenance on this equipment..3 Water Chemistry 4 Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation: Water Quality and Minerals Level Iron < 0.3 ppm (0.3 mg/l) Hardness* < 7 gpg (0 mg/l) Turbidity < NTU Manganese < 0.05 ppm (0.05 mg/l) Tannins < 0. ppm (0. mg/l) UV Transmittance > 75% (call factory for recommendations on applications where UVT < 75%) * Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of your UV disinfection system. These water quality parameters can be tested by your local dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the UV disinfection system to operate as intended.

5 General Information Section General Information Figure System Components Item Description Part Number UV Systems Filter Housing AWP40B-V VH00-F0 AWP4B-V VH40-F0 Sediment cartridge filter 0 High 5 micron CMB-50-HF VH00-F0 Sediment cartridge filter 0" High 5 Micron CMB-50-HF VH40-F0 SS Flexible Hose R VH00-F0 404-R VH40-F0 3 Bracket R Used on all systems. 4 Controller V/50-60HZ BA-ICE-CL Used on all systems. 5 IEC Replacement Power Cords For VIQUA ICE Controller (Sold Separately) NORTH AMERICAN (NEMA 5-5P), 3-PRONG GROUNDED CONTINENTAL EUROPEAN (CEE 7/7) -PIN WITH GROUND, SCHUKO UK VERSION (BS 363) 3-PRONG GROUNDED (5 AMP FUSE) 6003 AUSTRALIAN VERSION (AS 3) 3-PRONG GROUNDED 6009 NO CONNECTOR, 3-WIRE, BARE LEADS 6 UV lamp S00RL-HO VH00-F0 S40RL-HO VH40-F0 7 Gland Nut RN-00 Used on all systems. 8 O-ring Used on all systems. 9 Quartz Sleeve QS-00 VH00-F0 QSO-40 VH40-F0 0 Lamp Connector Base 7076-R Used on all systems. 304 Stainless Steel Chamber - - Spring SP008 Used on all systems. 5

6 Installation Section 3 Installation 3. UV Disinfection System The disinfection system is designed to be installed at point-of-entry. Drip loops in all cordage connected to the controller is highly recommended. Refer to Figure 3. The complete water system, including any pressure or hot water tanks, must be sterilized before start up by flushing with chlorine (household bleach) to destroy any residual contamination. Refer to Section 3.. For safety purposes, the disinfection system must be connected to a Ground Fault Protected Circuit (GFCI). The disinfection system is intended for indoor use only, do not install disinfection system where it may be exposed to the weather. Install the disinfection system on cold water line only. If treating the entire house, install the disinfection system before any branch lines. Procedure: CAUTION Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure the green ground wire ring terminal is securely fastened to chamber ground stud.. Figure shows the installation of a typical drinking water system and the related components that may be used for the installation. The use of a bypass assembly is recommended in case the system requires off-line maintenance. If this is the case, it must be noted that the system will require supplementary disinfection of the distribution system if any water is used during this bypass condition. In addition, during bypass, the water will NOT be disinfected and a DO NOT CONSUME THE WATER tag should be physically installed on the bypass assembly until such time as the system is sanitized and returned to service. Please refer to Section 3. for the complete disinfection procedure. If the water is to be consumed while the system is off-line, the water must be boiled for two minutes prior to consumption. VH00-F0 Figure Figure Disinfection System 6

7 Installation. Select a suitable location for the disinfection system and its related components. As it is recommended to install a ground fault protected circuit (GFCI), make sure that this is taken into consideration prior to any installation. When selecting a mounting location, enough space must be left to allow for the removal of the UV lamp sleeve, as well as enough space to change out the filter cartridges. See Figure 3 for typical clearance dimensions. Min. From Top to Unit 8 Overall Length Drip Loop Min. 4 From Bottom to Unit Figure 3 Disinfection Installation Note: The above illustration is relevant for VH00 only. 3. Mount the system to the wall with appropriate lag bolts (not supplied) through the two mounting holes located on the metal bracket. The use of a flow restrictor device is recommended when installing your system in order to maintain the manufacturers maximum rated flow. The flow restrictor should be installed on the outlet port and is designed to be installed in one direction only. Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor. Refer to Figure 4. Note: DO NOT solder connections while attached to the system as this could damage the O-ring seals. Figure 4 Flow Restrictor 7

8 Installation 4. Make sure you allow for a drip-loop on the power cord to prevent any water from potentially entering the controller. Refer to Figure Install the UV lamp. Refer to Section Install the cartridges. Refer to Section When all plumbing connections are made, slowly turn on the water supply and check for leaks. The most likely cause for leaks is from o-ring seals. In case of a leak at the chamber, shut water off, remove the retaining nut, wipe the o-ring and threads clean and re-install. In case of a leak at the filters, remove the sump, wipe the o-ring and threads clean, ensure the o-ring is properly seated, then reinstall. 8. Once it is determined that there are no leaks, plug the system into the ground fault interrupter, and check controller to ensure the system is operating properly.the controller is designed to detect both power to the system and UV lamp illumination. Note: DO NOT look directly at the glowing UV lamp. 9. Allow the water to run for a few minutes to clear any air or dust that may be in the chamber. Note: When there is no flow, the water in the cell will become warm, as the UV lamp is always on. To remedy this, run a cold water tap anywhere in the house for a minute to flush out the warm water. 3. Disinfection Procedure UV disinfection is a physical process and does not add any potentially harmful chemicals to the water. As UV does not provide a disinfection residual, it is imperative that the entire distribution system located after the UV be chemically disinfected to ensure that the water is free from any bacteriological contaminants. The disinfection process must be performed immediately after the UV unit is installed and repeated thereafter whenever the UV is shut down for service, without power, or inoperative for any reason. The procedure for sanitizing the plumbing system is readily accomplished as follows: 3 4 Ensure the controller is plugged in for entire disinfection process. Shut off the water supply. Close each faucet. Press the pressure button to release the pressure from the cartridges. Remove sump housing using sump wrench. 5 BLEACH Household 5.5% Bleach Solution x 0 30 mins Remove cartridge and pour cups of household bleach solution into the sump housing. Note: DO NOT use Hydrogen Peroxide. Connect only the sump housing to the unit. Turn on water supply. Allow water to fill the chamber. Turn on the cold water supply followed by hot water (if available) until you smell the bleach. Close all faucets and allow bleach to settle in the water lines for 30 minutes. 8

9 Installation 9 0 With all faucets closed, remove sump housing using sump wrench. Reinstall the cartridge into sump housing and connect to the unit. Flush all water outlets until bleach can no longer be smelled (at least 5 minutes). Press the pressure button to purge air and to complete the disinfection procedure. Notes: ) The addition of chlorine (bleach) to a hot water tank that has in the past been fed with untreated raw water with high levels of other contaminants (iron, manganese, hydrogen sulphide, organics, etc.) will result in oxidation of these contaminants and may require repeated flushing of the hot water tank. This contingency must be dealt with independently under the start-up procedure for any other conditioners that may form a part of the pre-treatment for the UV unit. ) The above disinfection procedure will result in a massive chlorine residual far in excess of the 0.5 to.0 mg/l typically present in municipally chlorinated water and of a magnitude consistent with the minimum 50 mg/l chlorine solution recommended for the disinfection of distribution systems known to be contaminated. Do not consume water until complete system has been flushed. 9

10 UV UV Maintenance Section 4 Maintenance WARNING Always disconnect power before performing any work on the disinfection system. Always shut-off water flow and release water pressure before servicing. Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present. Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection. Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures. 4. Replacing UV Lamp NOTICE Reset lamp life timer after lamp replacement. Refer to Section Refer to for UV lamp disposal. Do not use water during replacement of UV lamp. Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000 hours of continuous operation (approximately one year) in order to ensure adequate disinfection. Procedure: 3 4 Hg 0 0 mins Shut off the water line to chamber and release system pressure before servicing. Disconnect main power source and allow the unit to cool for 0 minutes. Remove the lamp connector by squeezing the plastic locking tabs on the side of the connector. Remove the lamp in upward direction from the chamber and lamp connector base. Always hold the lamp at the ceramic ends Hg click 3 4 Insert the new lamp fully into the chamber leaving about two inches of the lamp protruding from the chamber. Attach the connector to the lamp. Note that the connector will only allow correct installation in one position. Push the lamp connector against lamp connector base together until an audible click is heard. Hold down the timer reset button and reapply power to the controller until you see, then release timer reset button. A 5 second delay will occur until you hear an audible tone and LED display will read once again. Re-pressurize the system to check for leaks. 0

11 Maintenance 4. Cleaning and Replacing Quartz Sleeve Note: Minerals in the water slowly form a coating on the lamp sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced. Prerequisites: Shut off water supply and drain all lines. Remove the UV lamp. Refer to Section 4.. Procedure: Remove the bottom retaining nut, floating spring, and O- ring. Remove the top retaining nut and O-ring. Carefully, remove O-ring adhering to the quartz sleeve. Remove the quartz sleeve. Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild acid and then rinse with water. Note: If sleeve cannot be cleaned completely or it is scratched or cracked, then replace the sleeve click 3 Reinstall the quartz sleeve in the chamber allowing the sleeve to protrude an equal distance at both ends of the chamber. Slide supplied O-rings onto each end of the quartz sleeve. Reinstall the top and bottom retaining nuts, floating spring, and O-rings respectively. When service is complete, assemble the prerequisites in the reverse order of disassembly. Push the lamp connector against lamp connector base together until an audible click is heard. Re-pressurize the system to check for leaks. Plug in controller and verify the POWER-ON LED display is illuminated and controller power-up sequence operates Note: After replacing the UV lamp or quartz sleeve perform the disinfection procedure, refer to Section 3..

12 Maintenance 4.3 Replacing Cartridges It is recommended to change the filter cartridge every six months (or earlier). Please note that a drop in pressure may indicate that the filter cartridge requires replacement. Note: Prior to performing any work on the drinking water system, ALWAYS DISCONNECT THE CONTROLLER FIRST. As a small amount of water may leak from the cartridges during this procedure, please place a small bucket under the system to catch any water. Procedure:. Shut-off the water flow to the unit, depress pressure relief button on top of the filter head to relieve pressure in the filter. Refer to Figure 5. Figure 5 Pressure Relief Button. Place a bucket or pail under the stainless steel chamber. Remove retaining nut to drain system. 3. Remove the filter housing from the unit by turning the blue collar counter-clockwise until it falls free from the head. Pull down the white filter housing (be careful as it will be full of water and will be heavy). Refer to Figure 6. Figure 6 Removing Filter Housing

13 Maintenance 4. Discard the used cartridge and clean the sump housing as required. Make sure to thoroughly rinse the sump with water to remove any cleaning agents.before installing a new cartridge, please ensure that the o-ring seals are properly seated on the shoulders at the top of the sump (Refer to Figure 7), if there is any visible damage on the o-rings please replace them (P/N: OR40-50). 5. Ensure o-rings are liberally coated with a silicone based lubricant. 6. Install the new cartridge in the reverse procedure as stated above turning the collar clockwise until the sump is tight. Note: Do not over tighten. Figure 7 O-ring on Sump 7. Plug UV unit into the Ground Fault Circuit Interrupter (GFCI) outlet and power-up the system. 8. Slowly turn on the water supply and allow any air that may now be present to bleed off by depressing pressure relief button on top of the sump until air is purged from filter. Now you are ready to return the system to use. 3

14 Operation Section 5 Operation WARNING The advanced warning system has been installed to provide the optimum protection against microbiological contamination in water. DO NOT disregard the warning signals. The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on a regular basis. 5. Basic Systems Incorporating BA-ICE-CL Controllers 5.. Lamp Life Remaining (days) The controller tracks the number of days of operation of the UV lamp and the controller. The default screen will display the total lamp life remaining (in days). The controller will count down the number of days remaining until the UV lamp requires changing (365 days to day). At 0 days, the controller will display and sound an intermittent audible chirp ( second on, 5 seconds off), indicating the need to change the UV lamp. 5.. Understanding your A3 Code DEFERRAL - Once the A3 or end of lamp life message is shown on the LED display, the audible alarm can be deferred up to 4 separate times. The delay is designed to allow you time to address the alarm while you obtain a new UV lamp. This can be done by simply depressing the timer reset button for 5 seconds, which is located on the left side of the controller. Each time the timer reset button is pressed the controller alarm is deferred seven days. Once the final 7 day deferral has been reached the alarm can only be silenced by changing the UV lamp and manually resetting the controller timer, refer to Section Resetting Lamp Life Refer to Section 4.. Note: Even though the alarm on the system can be deferred for a period of time, it is important to address each and every alarm condition as they are indicating that there is a potential problem with the system and should be remedied Total Days of Operation The controller also displays the total running time of the controller. To obtain this reading, press the push-button once. The total running time of the controller will be numerically displayed in days. This information will remain displayed for ten seconds and will then revert back to the lamp life remaining default screen. It should be noted that this value cannot be reset Lamp Failure (Blank Screen) When the system recognizes LAMP FAILURE (no current running through the UV lamp), the display will be blank (no default LAMP LIFE REMAINING screen) and the system will sound an intermittent audible tone ( second on, second off). The system will remain in this state, until this condition is remedied. Not performance tested or certified by NSF. Figure 8 BA-ICE-CL Controllers 4

15 Troubleshooting Section 6 Troubleshooting Symptom Possible Causes Solutions Pressure Drop High Bacteria Counts Heated Product Water Water Appears Milky Chamber Leaking Water System Shutting Down Intermittently Lamp Failure Alarm on - New UV Lamp Sediment pre-filter clogged Quartz sleeve is stained or dirty Change in feed water quality Contamination in water lines after UV system (eg. due to a power failure, plumbing dead ends, etc.) Possible break-through of sediment through pre-filter Common concern caused by infrequent use of water Caused by air in the water lines Problem with O-ring seal (on retaining nut) Condensation on chamber caused by excessive humidity & cold water Inadequate inlet/outlet port connections Interrupted controller Loose connection between lamp and connector Moisture build up in connector may keep UV lamp and connector from making a solid connection Replace filter cartridge and refer to Section. Note: Check source water supply as fluctuations may occur in source pressure. Clean sleeve with scale cleaner and eliminate source of staining problem (ie. soften hard water, refer to Section 4.. Have source water tested to ensure that water quality is still within allowable limits for this system. Refer to Section 3., Disinfection Procedure to disinfect your system. Test source water for turbidity - may need stepped filtration in order to catch all sediment entering water system (0 micron filter followed by a 5 micron filter followed by UV system). Run water until it returns to ambient temperature. Install temperature management valve. Run water until air is purged. Ensure O-ring is in place, check for cuts or abrasions, clean O-ring, moisten with water/ lubricant and re-install, replace if necessary (Refer to Section for part number). Check location of disinfection system and control humidity. Check thread connections, reseal with Teflon tape and re-tighten. Ensure system has been installed on its own circuit, as other equipment may be drawing power away from UV (ie. pump or fridge). UV system should not be installed on a circuit which is incorporated into a light switch. Disconnect the UV lamp from connector and reconnect, ensuring that a tight fit is accomplished Eliminate chance of any moisture getting to the connector and/or lamp pins DISPLAY FAULT MODES LED display reads A3 Lamp life expired - countdown is at 0 days Press reset button for a deferred alarm, replace UV lamp (refer to Section 4.). Controller is in lamp failure mode LED display is blank Power system down, allowing it to reset itself; apply power in order to confirm that the controller is able to power lamp Check to see if there is sufficient power to the UV system 5

16 Manufacturer's Dose Flow Chart Section 7 Manufacturer's Dose Flow Chart 3 VH40-F0 VH00-F0 VIQUA Standard Figure 9 Dose Flow Chart Not performance tested or certified by NSF. 6

17 Specifications Section 8 Specifications 8. Standard and Validated Model VH00-F0 VH40-F0 Flow Rate US Public Health 6 mj/cm 6 GPM (60 lpm) (3.6 m 3 /hr) 34 GPM (30 lpm) (7.8 m 3 /hr) VIQUA Standard 30 mj/cm 9 GPM (34 lpm) (.0 m 3 /hr) 8 GPM (70 lpm) (4. m 3 /hr) NSF/EPA 40 mj/cm 7 GPM (6 lpm) (.6 m 3 /hr) 4 GPM (54 lpm) (3.3 m 3 /hr) Overall Dimensions (width x depth x height) 7 x 0.5 x 7.8 7" x 0" x 9" Inlet/Outlet Port Size FNPT/Combo 3/4 FNPT & MNPT 3/4 FNPT Shipping Weight 0.5 kg (3 lbs) 3. kg (9 lbs) Voltage V/ 50/60 Hz V/ 50/60 Hz Electrical Max. Current.5 Amp.5 Amp Power Consumption 35 W 60W Lamp Watts 7 W 45W Maximum Operating Pressure 00 psi (689 kpa) 00 psi (689 kpa) Minimum Operating Pressure 5 psi (03 kpa) 5 psi (03 kpa) Ambient Water Temperature -40 C (36-04 F) -40 C (36-04 F) UV Lamp Type Sterilume - HO (high output) Sterilume - HO (high output) Visual Power-On Yes Yes Audible Lamp Failure Yes Yes Lamp Replacement Reminder Yes Yes Visual Lamp Life Remaining Yes Yes Total Running Time Yes Yes 54 nm UV Monitor No No Solenoid Output (solenoid not incl.) No No Chamber Material 304 SS 304 SS Filter Housing 0 high flow 0 high flow 7

18 Manufacturer s Warranty Section 9 Manufacturer s Warranty Our Commitment VIQUA is committed to ensuring your experience with our products and organization exceeds your expectations. We have manufactured your UV disinfection system to the highest quality standards and value you as our customer. Should you need any support, or have questions about your system, please contact our Technical Support team at or technicalsupport@viqua.com and we will be happy to assist you. We sincerely hope you enjoy the benefits of clean, safe drinking water after the installation of your VIQUA disinfection system. How to Make a Warranty Claim Note: To maximise the disinfection performance and reliability of your VIQUA product, the system must be properly sized, installed and maintained. Guidance on the necessary water quality parameters and maintenance requirements can be found in your Owner s Manual. In the event that repair or replacement of parts covered by this warranty are required, the process will be handled by your dealer. If you are unsure whether an equipment problem or failure is covered by warranty, contact our Technical Support team at or technicalsupport@viqua.com. Our fully trained technicians will help you troubleshoot the problem and identify a solution. Please have available the model number (system type), the date of purchase, the name of the dealer from whom you purchased your VIQUA product ( the source dealer ), as well as a description of the problem you are experiencing. To establish proof of purchase when making a warranty claim, you will either need your original invoice, or have previously completed and returned your product registration card via mail or online. Specific Warranty Coverage Warranty coverage is specific to the VIQUA range of products. Warranty coverage is subject to the conditions and limitations outlined under General Conditions and Limitations. Ten-Year Limited Warranty for VIQUA UV Chamber VIQUA warrants the UV chamber on the VIQUA product to be free from defects in material and workmanship for a period of ten (0) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective VIQUA UV chamber. Please return the defective part to your dealer who will process your claim. Three-Year Limited Warranty for Electrical and Hardware Components VIQUA warrants the electrical (controller) and hardware components to be free from defects in material and workmanship for a period of three (3) years from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty. Please return the defective part to your dealer who will process your claim. One-Year Limited Warranty for UV lamps, Sleeves, and UV Sensors VIQUA warrants UV lamps, sleeves, and UV sensors to be free from defects in material and workmanship for a period of one () year from the date of purchase. During this time, VIQUA will repair or replace, at its option, any defective parts covered by the warranty.your dealer will process your claim and advise whether the defective item needs to be returned for failure analysis. Note: Use only genuine VIQUA replacement lamps and sleeves in your system. Failure to do so may seriously compromise disinfection performance and affect warranty coverage. General Conditions and Limitations None of the above warranties cover damage caused by improper use or maintenance, accidents, acts of God or minor scratches or imperfections that do not materially impair the operation of the product. The warranties also do not cover products that are not installed as outlined in the applicable Owner s Manual. Parts repaired or replaced under these warranties will be covered under warranty up to the end of the warranty period applicable to the original part. The above warranties do not include the cost of shipping and handling of returned items.the limited warranties described above are the only warranties applicable to the VIQUA range of products. These limited warranties outline the exclusive remedy for all claims based on a failure of or defect in any of these products, whether the claim is based on contract, tort (including negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for a particular purpose shall apply to any of these products. VIQUA does not assume any liability for personal injury or property damage caused by the use or misuse of any of the above products. VIQUA shall not in any event be liable for special, incidental, indirect or consequential damages. VIQUA s liability shall, in all instances, be limited to repair or replacement of the defective product or part and this liability will terminate upon expiration of the applicable warranty period. 8

19 45 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) tf. (+) (US and Canada only) t. (+3) (Europe only) f. (+) info@viqua.com

HQUA. UV Water Sterilizer Instruction Manual. Contents

HQUA. UV Water Sterilizer Instruction Manual. Contents UV Water Sterilizer Instruction Manual Contents Section 1 Safety Information 2-3 Section 2 General Information.4-7 Section 3 Maintenance.7-9 Section 4 Troubleshooting.10 Section 5 After-Sales Service...10

More information

Owner s Manual. Models: VT1, VT1/2, VT1/2A, VT1/2B, VT1/12 VT4, VT4/2, VT4/2A, VT4/2B, VT4/12. Powered by _RevP

Owner s Manual. Models: VT1, VT1/2, VT1/2A, VT1/2B, VT1/12 VT4, VT4/2, VT4/2A, VT4/2B, VT4/12. Powered by _RevP Owner s Manual Models: VT, VT/, VT/A, VT/B, VT/ VT4, VT4/, VT4/A, VT4/B, VT4/ Powered by 45 Clair Rd. W, Guelph, Ontario, Canada NL R t. (+) 59.76.0 tf. (+) 800.65.746 (US and Canada only) t. (+) 7 747

More information

OWNER'S MANUAL PURIFY WATER 99.99% FREE OF BACTERIA AND VIRUSES! Model IHS12-D4 and IHS12-D4/2 WHOLE HOME UV DISINFECTION SYSTEM

OWNER'S MANUAL PURIFY WATER 99.99% FREE OF BACTERIA AND VIRUSES! Model IHS12-D4 and IHS12-D4/2 WHOLE HOME UV DISINFECTION SYSTEM WHOLE HOME UV DISINFECTION SYSTEM Model IHS-D4 and IHS-D4/ OWNER'S MANUAL PURIFY WATER 99.99% FREE OF BACTERIA AND VIRUSES! Congratulations. By purchasing this system, you have taken the first step in

More information

Ultraviolet Sterilization System Installation Instructions & Owner s Manual

Ultraviolet Sterilization System Installation Instructions & Owner s Manual Your best choice in Ultraviolet Sterilization RoHS COMPLIANT Ultraviolet Sterilization System Installation Instructions & Owner s Manual For models: UV-1, UV-2, UV-6, UV-8C, UV-12C, UV-24B UV-100B Table

More information

Owner s Manual. PUV-Basic PUV-8 PUV-16. (NSF Standard 55 Class B Certified)

Owner s Manual. PUV-Basic PUV-8 PUV-16. (NSF Standard 55 Class B Certified) Owner s Manual PUV-Basic PUV-8 PUV-16 (NSF Standard 55 Class B Certified) Congratulations. By purchasing this system, you have taken the first step in ensuring safe drinking water. Designed using the most

More information

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs! Laboratory Series Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual KEEP THIS MANUAL ON HAND IT IS IMPORTANT THAT THOSE RESPONSIBLE FOR THE INSTALLATION OF THIS EQUIPMENT,

More information

Owner s Manual WARNING

Owner s Manual WARNING Filter Housing Models: AWP20C-V, AWP30C-V, AWP32B-V. Overview: Owner s Manual VIQUA offers a variety of housing sizes and styles in durable, molded polymer that defies rust and corrosion, and ensures a

More information

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL GUV-SHIELD, GUV-SHIELD-MAN SERIES UV Systems Model numbers: GUV-7 GUV-SHIELD-7 GUV-SHIELD-7-MAN GUV-SHIELD-10 GUV-SHIELD-10-MAN GUV-SHIELD-15

More information

Crystal Quest Ultraviolet Disinfection System Installation and Operation Guide

Crystal Quest Ultraviolet Disinfection System Installation and Operation Guide Crystal Quest Ultraviolet Disinfection System Installation and Operation Guide OPERATING SPECIFICATIONS Pressure Range: Temperature Range: Optimum Service Flow: 30-60 psi (2.1-4.1 bar) 40-100ºF (4.4-37.7ºC)

More information

Crystal Quest UltraViolet Disinfection System INSTALLATION AND OPERATION GUIDE

Crystal Quest UltraViolet Disinfection System INSTALLATION AND OPERATION GUIDE Crystal Quest UltraViolet Disinfection System INSTALLATION AND OPERATION GUIDE MODELS: CQE-UV-00101 1 GPM CQE-UV-00106 36 GPM CQE-UV-00102 6 GPM CQE-UV-00107 48 GPM CQE-UV-00103 8 GPM CQE-UV-00108 60 GPM

More information

gamma uv Aquarium Ultraviolet Sterilizers

gamma uv Aquarium Ultraviolet Sterilizers gamma uv Aquarium Ultraviolet Sterilizers Instructions for Models #1400 8w, 1401 15w, 1402 25w Important Safety Instructions... Page 2 Installation... Page 3 8/15/25 watt Alternate Diagrams... Page 5 25

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTColdBevMax Installation, Operation and Maintenance Manual QT TM Cold Bev Max TM Models: QTCLDBMX-1S-.5M, QTCLDBMX-2S-.5M, QTCLDBMX-3S-.5M, QTCLDBMX-4S-.5M, QTCLDBMX-5S-.5M Tested and Certified

More information

INSTALLATION INSTRUCTION & OWNER S MANUAL

INSTALLATION INSTRUCTION & OWNER S MANUAL CS-2500 & CS-2500P Water Filtration System INSTALLATION INSTRUCTION & OWNER S MANUAL Ver 1.2 All Rights Reserved APEC Water Systems Please keep this Owner s Manual for future reference. It contains useful

More information

Engineered to Higher Standards

Engineered to Higher Standards Engineered to Higher Standards G, H, J, K & Pro50 www.uvmax.com Engineered to Higher Standards The technology and care that goes into the development of our products is of the highest standards. Our UV

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1099-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter The world leader in products for a healthy and comfortable environment - bringing the Garden of Eden into your home. AQUA2000 OWNER S MANUAL INCLUDES: Restrictions Installation Operation Maintenance Changing

More information

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Dual/Triple Manifold Water Filtration Systems Instruction Manual 3M TM Water Filtration Products Dual/Triple Manifold Water Filtration Systems Instruction Manual High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator. 3M Water

More information

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS SUBMERSIBLE SUMP PUMPS Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODELS #1073-0001, 1075-0001 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual IOM-HS-QTCubeMax Installation, Operation and Maintenance Manual QT TM Cube Max TM Models: QTCBMX-1S-1M, QTCBMX-2S-1M, QTCBMX-3S-1M, QTCBMX-4S-1M, QTCBMX-1L-1M, QTCBMX-2L-1M, QTCBMX-3L-1M, QTCBMX-4L-1M,

More information

Dual Flow Manifold Systems Instruction Manual

Dual Flow Manifold Systems Instruction Manual 3M TM Water Filtration Products Dual Flow Manifold Systems Instruction Manual For DF1XX and DF2XX High Flow Series manifolds and water filtration systems Installer: Please leave this manual with owner/operator.

More information

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by: Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

SUPER PUMP OUT SYSTEM

SUPER PUMP OUT SYSTEM Congratulations on your purchase of the SUPER PUMP OUT SYSTEM. This instruction/parts manual is a guide for operating and servicing your BLUELINE SUPER PUMP OUT SYSTEM. Proper operation and service are

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

Scale Feeder Manifold Water Filtration System Instruction Manual

Scale Feeder Manifold Water Filtration System Instruction Manual 3M TM Water Filtration Products Scale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems Installer: Please leave this manual with owner/operator.

More information

AQUA2000 From O3PURE

AQUA2000 From O3PURE AQUA2000 From O3PURE OWNER S MANUAL INCLUDES: RESTRICTIONS INSTALLATION OPERATION MAINTENANNCE CHANGING THE FILTER CHANGING THE UV LAMP SPECIFICATIONS WARRANTY ADVANCED WATER TREATMENT SYSTEMS CAUTION:

More information

WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S

WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT SERIES NO'S 1 2 4 7 Sold by: Manufactured by: WEDECO Ideal Horizons, Inc. 3520 Westinghouse

More information

UVMAX Light Commercial Series Model description weight NOTES

UVMAX Light Commercial Series Model description weight NOTES UVMAX Light Commercial Series 80 GPM K - 80 gpm disinfection, with 2 MNPT inlet/outlet connections on a 316L SS reactor. System comes equipped with an LPHO amalgam UV lamp, and CoolTouch fan to reduce

More information

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit. NANO INDUCT Owner s Manual For use with models: NIND14, NIND9, NIND6 For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit. Thank You for

More information

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed

More information

OPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R

OPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R OPERATIONS AND MAINTENANCE MANUAL EcoStream Models ECS60R / ECS100R / ECS150R 2 TABLE OF CONTENTS TABLE OF CONTENTS... 3 SAFETY INSTRUCTIONS... 4 OVERVIEW... 5 Reactor Chamber... 5 Control Panel... 5 Standard

More information

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Users Manual Certified Series Direct Drive Pump 1-7 LPM Users Manual Certified Series Direct Drive Pump 1-7 LPM Safety, Operating, Installation, and Maintenance Instructions 600 S 56 th Street #9 Chandler, AZ 85226 Phone: 480-507-6478 Fax: 480-838-2232 www.fogco.com

More information

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

Full Flow Drinking Water System Model: 3MFF100

Full Flow Drinking Water System Model: 3MFF100 Installation and Operating Instructions For Full Flow Drinking Water System Model: 3MFF100 System tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of the

More information

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning

More information

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350 DFA Series Rainwater/Graywater Filtration Systems MODELS: DFM-2F-180 DFM-3F-180 DFM-3F-350 DFA-2F-180 DFA-3F-180 DFA-3F-350 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. PEDESTAL SUMP PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1084-0001 Español p. 11 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing

More information

ProFlo FatBoy

ProFlo FatBoy The Standard For Professional Grade Diaphragm Pumps. ProFlo 3300 5500 FatBoy Operational and Installation Guidelines, Repair & Parts Contents 3300 5500 Fatboy Operational and Installation Guidelines...2

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual IOM-WQ-SmartStream-A 254 Nanometer Germicidal UV Disinfection Systems Models WA002 WA006 WA008 WA012 SmartStream UV Chemical Free Disinfection of Water Read

More information

US Water ORP Booster Injection System

US Water ORP Booster Injection System US Water ORP Booster Injection System US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 info@uswatersystems.com www.uswatersystems.com REVISION 1.1, 9-14-15 Table of Contents

More information

Installation & Service Manual

Installation & Service Manual Installation & Service Manual Table of Contents Unpacking and Inspection... 3 Specifications... 3 Installation Directions... 3 Product Installation Sequence... 4 Replacing EWUV Bulb... 4 Servicing EWUV

More information

Gauge Adapter Instruction Manual

Gauge Adapter Instruction Manual Instruction Manual MODELS: CF3812, CF3812E, CF3814 & CF4514 CF3812-M1_092017! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that

More information

AUTOMATIC SUBMERSIBLE UTILITY PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP AUTOMATIC SUBMERSIBLE UTILITY PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1043-0006 Español p. 9 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

GARDEN HOSE UTILITY PUMP

GARDEN HOSE UTILITY PUMP GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before

More information

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit. NANO INDUCT Owner s Manual For use with models: NIND14, NIND9, NIND6 For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit. Thank You for

More information

Fission. Nano-Protein Skimmer. Instructions for Model#8100

Fission. Nano-Protein Skimmer. Instructions for Model#8100 Fission Nano-Protein Skimmer Instructions for Model#8100 Warning and Safety Instructions... Page 2 Skimmer Assembly... Page 3 Skimmer Installation... Page 5 Skimmer Maintenance... Page 7 Warranty... Page

More information

Hydraulic Immediate Need Power Pack

Hydraulic Immediate Need Power Pack Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read

More information

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance Power Controller Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the Power Controller from Blichmann Engineering. We are confident that it will provide

More information

Manifold w/ Needle Valve Instruction Manual

Manifold w/ Needle Valve Instruction Manual MODELS: MFC2 & MFC4 Manifold w/ Needle Valve Instruction Manual SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com

More information

Water Dispenser Owner s Manual 100 Series

Water Dispenser Owner s Manual 100 Series TM Water Dispenser Owner s Manual 100 Series IMPORTANT: This manual includes important safety material; please read all instructions before plugging power supply cord into receptacle. 1 2 3 Load water

More information

StormPro BA Series Sump Pump

StormPro BA Series Sump Pump Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:

More information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14 SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

PRE-PLUMBED SEWAGE SYSTEM

PRE-PLUMBED SEWAGE SYSTEM PRE-PLUMBED SEWAGE SYSTEM Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1910-0009 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems,

More information

Heated Bakery Merchandiser Series. Series: WBC Operation Manual

Heated Bakery Merchandiser Series. Series: WBC Operation Manual Heated Bakery Merchandiser Series Series: WBC Operation Manual WHAT IS COVERED WHO IS COVERED COVERAGE PERIOD WARRANTY COVERAGE EXCEPTIONS EXCLUSIONS INSTALLATION BKI LIMITED WARRANTY 2812 Grandview Drive

More information

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13 GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?

More information

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems The Fresh-Aire UV Airborne Duct System is designed for installation into commercial HVAC system ducts for

More information

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

RipTide. Brewing Pump. Assembly, Operation, & Maintenance RipTide Brewing Pump Assembly, Operation, & Maintenance Congratulations on your purchase, and thank you for selecting the RipTide brewing pump from Blichmann Engineering. We are confident that it will

More information

US Water Systems Magna Pre-Filter

US Water Systems Magna Pre-Filter Visit us online at www.uswatersystems.com US Water Systems Magna Pre-Filter Owners Manual 320-USP-MF-10, 320-USP-MF-20 REVISION # 1.3 REVISION DATE October 9, 2018 US Water Systems Corporate Office 1209

More information

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting. USER S GUIDE 2880 SERIES 3 Safety Instructions 4 Product View 4-5 Assembly 5 Operation 6 Maintenance and Care 7 Troubleshooting 7 Replacement Parts 8 Warranty Thanks for buying a BISSELL Perfect Sweep

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

Owner s Manual GLASSLINED PUMP TANK

Owner s Manual GLASSLINED PUMP TANK Owner s Manual GLASSLINED PUMP TANK ANSI/NSF 61 Annex G Thank You for purchasing a pump tank. Properly installed and maintained, it should give you years of trouble free service. If you should decide that

More information

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual MP7428 12V 8A Electronic Smart Charger Instruction and Information Manual In order to ensure correct and safe usage of your battery charger, you should read these instructions carefully. Please retain

More information

Dual Port Manifold Water Filtration Systems Instruction Manual

Dual Port Manifold Water Filtration Systems Instruction Manual M TM Water Filtration Products Dual Port Manifold Water Filtration Systems Instruction Manual For DP1XX, DP2XX and DPXX High Flow Series Water Filtration Systems Installer: Please leave this manual with

More information

Instruction & Owner s Manual

Instruction & Owner s Manual Instruction & Owner s Manual Table of Contents Page Installation - Plumbing of Chamber 3 Installation - Electronic Control Box 3-4 Transformer Connection 115VDC or 230VDC 4-5 Instructions for use with

More information

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System

MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System MODEL CJ-200E CoilJet Portable HVAC Coil Cleaning System OPERATING AND MAINTENANCE INSTRUCTIONS 404 West Avenue Stamford, CT 06902 (888)700-3540 www.speedclean.com COILJET is a registered trademark of

More information

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual Version 1.1 Version 2 Nature Power Inverters True Sinewave Inverter Modified Sinewave Inverter Owner s Manual!!!!!!!!!!! 38304 38204 For safe and optimum performance, the Power Inverter must be used properly.

More information

4" 4" 4 1/4" 11" TOP VIE 3 1/8" Ø1/2" 2" 10 3/8" SIDE VIE VG05002 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1/8"

4 4 4 1/4 11 TOP VIE 3 1/8 Ø1/2 2 10 3/8 SIDE VIE VG05002 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1/8 FAUCET SPECIFICATIONS all Mount Bathroom Faucet Model VG05002 MODEL VG05002 FEATURES Solid brass construction Single hole construction Ceramic disk cartridge Single lever faucet all mount installation

More information

Document No B6 Revised December Atlantic Ultraviolet Corporation

Document No B6 Revised December Atlantic Ultraviolet Corporation 375 Marcus Boulevard Hauppauge, NY 11788 USA 631.273.0500 Fax: 631.273.0771 e-mail: info@ultraviolet.com Extensive Product Information Available at: www.ultraviolet.com Document No. 98-1124B6 Revised December

More information

USER'S GUIDE 9151 SERIES V

USER'S GUIDE 9151 SERIES V USER'S GUIDE 9151 SERIES 220-240 V 2 Thank You 3 Safety Instructions 4 Product View 4-5 Assembly 5 Operations 6 Maintenance and Care 7 Troubleshooting 7 Replacement Parts 8 Warranty 8 Consumer Care Thanks

More information

Hydraulic PTO Flow Device

Hydraulic PTO Flow Device Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read

More information

INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS

INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES INTRODUCTION DESCRIPTIONS AND DEFINITIONS CONDITIONS FOR USE

More information

1/2 HP SUMP PUMP OWNER'S MANUAL

1/2 HP SUMP PUMP OWNER'S MANUAL TM 1/2 HP SUMP PUMP OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS PumpSpy Tech Support: 515.999.6935 support@pumpspy.com 34000 LEAR INDUSTRIAL PARKWAY, AVON, OH 44011 PumpSpy PS1000 12 VDC Sump Pump Power Supply Requirements

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

FAUCET SPECIFICATIONS. Wall Mount Bathroom Faucet Model VG " 10 3/8" MODEL VG05002

FAUCET SPECIFICATIONS. Wall Mount Bathroom Faucet Model VG  10 3/8 MODEL VG05002 FAUCET SPECIFICATIONS all Mount Bathroom Faucet Model VG05002 MODEL VG05002 FEATURES Solid brass construction Single hole construction Ceramic disk cartridge Single lever faucet all mount installation

More information

HARDWARE KIT INSTALLATION GLOVES

HARDWARE KIT INSTALLATION GLOVES COIL MOUNT STEEL DUCT MOUNT DUCTBOARD MOUNT CLAMP PLATE Z-BRACKET PCO BRACKET SHIELDED LAMP ASSEMBLY ALSO INCLUDED BALLAST TECH MANUAL HARDWARE KIT INSTALLATION GLOVES Rev 1 Issued: 09/03/2014 SERVICE

More information

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Installation Operation Repair Parts PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps Specifications Motor Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated Leads: 14 AWG, 12

More information

Power Inverter 400 MW Owner s Manual

Power Inverter 400 MW Owner s Manual Power Inverter 400 MW 1204 Owner s Manual For safe and optimum performance, the Power Inverter must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save Save This This Manual Keep Keep this this manual manual for for the the safety safety warnings warnings and and precautions, assembly, assembly, operating, inspection,

More information

VSP SERIES Installation, Operation and Maintenance Manual

VSP SERIES Installation, Operation and Maintenance Manual VSP SERIES Installation, Operation and Maintenance Manual VARIABLE SPEED PERISTALTIC METERING PUMPS VSP-12 and VSP-20 Models READ ALL WARNINGS CAREFULLY BEFORE INSTALLING PUMP PUMP DATA/SPECIFICATIONS

More information

Operator s Safety and Service Manual

Operator s Safety and Service Manual Operator s Safety and Service Manual Cordless Sprayer Model: H100AC ALL CHEMICALS SMK Industries, Inc. 12839 Carpenter Trail Carlisle, IA 50047 Phone: 515-202-0052 Copyright 2014, SMK Industries Inc Email:john@smksprayers.comWeb:

More information

Value Super Filter Max Installation Manual

Value Super Filter Max Installation Manual Value Super Filter Max Installation Manual Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR VALUE SUPER FILTER MAX INSTALLATION MANUAL INSTALLATION PROCEDURES: The Value Super Filter Max

More information

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference Audi R8 Ride-on Car 5F62630 OWNER S MANUAL Keep instructions for future reference 1 Safety The owner s manual contains assembly, use and maintenance instructions. The vehicle must be assembled by an adult

More information

SUBMERSIBLE MINI-PUMP

SUBMERSIBLE MINI-PUMP SUBMERSIBLE MINI-PUMP Model 41287 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from

More information

Clevis Plunger & Base Instruction Manual

Clevis Plunger & Base Instruction Manual MODELS: CED09 & CED16 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 - Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com CED09-M0_102017 Clevis

More information

WARNING Carefully Read These Instructions Before Use

WARNING Carefully Read These Instructions Before Use DO NOT RETURN THIS SPRAYER TO STORE Call: 1-800-950-4458 Backpack Sprayer Use and Care Manual Manufactured for Northern Tool + Equipment Co., Inc. WARNING Carefully Read These Instructions Before Use Model

More information

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Level One Electric Vehicle Charging Station FREE STANDING Product Guide Level One Electric Vehicle Charging Station FREE STANDING Product Guide Model # SC2-120 Shorepower Technologies 2351 NW York St. Portland, OR 98664 503-892-7345 info@shorepower.com www.shorepower.com 2

More information

Owner s Information Manual

Owner s Information Manual 50ES---A and 50VL---C Comfort 13SEERThreePhase2½---5NominalTons (Sizes 30---60) Comfort 14 SEER Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Single Packaged Air Conditioner System With Puronr

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves

More information

PURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.

PURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important. Installation, Operation and Maintenance Manual 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG IOM-WQ-PWSYS-UV-3STG PURE WATER Important Please read the entire manual before proceeding with

More information

Escort Stair Lift. Owner's Manual

Escort Stair Lift. Owner's Manual Escort Stair Lift Owner's Manual Read and understand this manual thoroughly before attempting to install or operate the lift. If you have any questions, please contact your Authorized AmeriGlide Dealer

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: 2 Please read the safety and installation instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Photo-catalytic Air Purifier. WARNING: FAILURE

More information

Swing Arm Magnifying Lamp

Swing Arm Magnifying Lamp Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Level One Electric Vehicle Charging Station Wall Mount Product Guide Level One Electric Vehicle Charging Station Wall Mount Product Guide Model # WU-120 ShorePower Technologies 2351 NW York St. Portland, OR 98664 503-892-7345 info@shorepower.com www.shorepower.com 2 Table

More information

25 GALLON PORTABLE OIL LIFT

25 GALLON PORTABLE OIL LIFT 25 GALLON PORTABLE OIL LIFT Model 92859 SET UP AND OPERATING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

18VDC ESB6 Series Cordless Screwdrivers Operation Manual 18VDC ESB6 Series Cordless Screwdrivers Screwdriver Models : ESB6-8, ESB6-12, ESB6-15, ESB6-22 CAUTION - Please read, understand, and follow all operating and safety instructions in this manual before

More information