SR7 Micro-infusion Syringe Pump. Contents

Size: px
Start display at page:

Download "SR7 Micro-infusion Syringe Pump. Contents"

Transcription

1

2 Contents Introduction 2 A. About this manual.2 B. Manufacturer s Responsibility.2 C. Warranty 3 D. Unpacking and Accessories.. 3 E. General Safety Overview Operating Principle Technical Specifications Operation Stand by and charge Power ON and Self-check Syringe Installation and Settings Rate Setting Volume To Be Infused Setting Occlusion Pressure Setting Selection of syringe brands Fast Infusion Total Volume Alarms Standard RS232 port Pump Installation Troubleshooting Maintenance Packing List Warranty Terms and Conditions..18 1

3 Introduction A. About This Manual This operator s manual has been prepared to provide information on the correct use of the DIGICARE BIOMEDICAL TECHNOLOGY INC. Digipump SR7 Syringe Infusion Pump. It contains performance specifications and installation, operation and maintenance information. It is intended for trained health care professionals. Follow each chapter in the manual sequentially if the infusion pump is being used for the first time. B. Manufacturer s Responsibility The manufacturer of this equipment is responsible for the effects on safety, reliability, and performance of the equipment only if: The equipment is used in accordance with the instructions in this manual. The electrical installation complies with all applicable regulations. Assembly operations, extensions, re -adjustments, or repairs are carried out by personnel authorized by the manufacturer. It is up to the user to ensure that any applicable regulations respecting the installation and operation of the infusion pump be observed. The operator should read this manual carefully and thoroughly before attempting to use the infusion pump. Incorrect operation or failure of the user to maintain the infusion pump in accordance with proper maintenance procedures relieves the manufacturer or his agent from all consequent non -compliance, damage or injury. 2

4 C. Warranty All products manufactured by Digicare Biomedical Technology Inc. are warranted to be free from defects in material and workmanship and to operate within published specifications, under normal use, for a period of one year from date of original shipment. The warranty on accessories is ninety (90) days. If an examination by Digicare, discloses such products or component parts be been defective, then our obligation is limited to repair or replacement (at our option). D. Unpacking and Accessories Carefully remove the infusion pump and its accessories form the shipping carton. Save the packing materials in case the infusion pump must be shipped or stored. Ensure your Digipump SR7 has the items listed in the SHIPPING LIST inside the carton. E. General Safety E.1 Indications The Digipump SR7 infusion pump is a device designed for continuous operation. It is intended for use by person s trained in professional health care. The operator must be thoroughly familiar with the instructions in this manual before using the instrument. E.2 Warnings The Digipump SR7 infusion pump was designed and tested accordingly to the EMC Standard IEC However, the operator is responsible to verify if the infusion pump is been affected or affecting others electrical equipment. Equipments like electrocautery and image scanners can generate interference and cause degradation of the Digipump SR7 infusion pump performance. To avoid this situation, it should be installed as far as possible of those equipment. The Digipump SR7 infusion pump is NOT intended to be used during MRI (magnetic resonance imaging). 3

5 The Digipump SR7 infusion pump is NOT suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide. Do not operate this product in the presence of flammable anesthetics. Explosion may result. Follow the instructions on this manual. Set the parameters appropriately and use only perfusor lines specified for the DigiPump SR7. Stop the device immediately in case of any abnormal functioning of the infusion pump. Keep the DigiPump SR7 far, at least 1 meter (3.0 feet) from other generating HF equipments such as electrosurgical unit and others. Before using the infusion pump, make sure the AC voltage at your installation site is correct for the AC rating for the device. If the rating is not correct, do not use the infusion pump and contact Digicare Customer Service for help. Hold on the plug firmly when plugging in or pulling out the power cord. Do not touch the power plug with wet hand. Do not share the same power outlet with other appliances. Do not disassemble the device or modify it. Perform daily check before use. Make sure all functions perform well if the infusion pump is not being in use. The SR7 syringe pump has been calibrated for use with single -use disposable syringes. To ensure correct and accurate ope ration, only use Luer-Lock versions of the syringe brands specified on the pump or described in this manual. Use of non-specified syringes or administration sets may impair the operation of the pump and the accuracy of the infusion. Uncontrolled flow rate may result if the syringe is placed incorrectly in the pump or if it is removed from the pump before the extension line is 4

6 properly removed from the patient. When combining several apparatus and /or instruments with administration sets and other tubing, like for example a 3 way, the performance of the pump may be impacted and should be monitored closely. The pump must be mounted within 1.0m above or below the patient s heart. Do not mount the pump in a vertical position with the syringe pointing upwards as this could lead to an infusion of air which may be in the syringe. To protect against the introduction of air, the user should regularly monitor the pro gress of the infusion, syringe, extension line and patient connections and follow the priming procedure specified herein. This is a positive pressure device designed to achieve very accurate fluid administration by automatically compensating for resistance encountered in the infusion system. The pumping pressure alarm system is not designed to provide protection against, or detection of, infiltration conditions that can occur at low pressures. Several alarm conditions detected by this pump will stop the infusion and generate audible and visual alarms. Users must perform regular checks to ensure that the infusion is progressing correctly without alarms. If this instrument is dropped, subjected to excessive moisture, fluid spillage, humidity or high temperature, or otherwise suspected to have been damaged, remove it from use for inspection by a qualified service engineer. When transporting or storing the pump, use original packaging where possible, and verify temperature, humidity and pressure ranges stated in this manual. Electric shock hazard exists if the pump s case is opened o r removed. Refer all servicing to qualified service personnel. 5

7 When connected to an external power source, a three-wire (Live, Neutral, Ground) supply must be used. If the integrity of the external protective conductor in the installation or its arrangement is in doubt, the equipment should be operated only from it s internal battery. After long-term use, the keys in the front panel can become caved in. This can cause errors in the ope ration of the pump. If this happen please call Digicare for service. Use only disposable syringe designated by Digicare. Otherwise inaccurate rate and incomplete infusion may occur. When LOW-BATT alarm is triggered, the pump must be immediately plugged to AC or powered off. Operating the pump in it s internal battery until fully depleted can cause failure and damage to the battery. After pressing FAST key, observe whether flow rate returns to original flow rate programmed. If it keep the same flow rate as the FAST, stop the pump and verify correct operation. Contact Digicare for service. The pump shall be clamped or reliably fastened by the user. It cannot be laid on flat surface or rail to avoid sliding of the pump. Connect the power cable to the pump in shutdown condition. Defective batteries shall be displaced following local environmental protection authority. When connected to an external power source, a three-wire (Live, Neutral, Ground) supply must be used. If the integrity of the external protective conductor in the installation or its arrangement is in doubt, the equipment should be operated only from it s internal battery. This pump belongs to continuous operation device type I equipment with BF isolation. The symbol Indicates type BF equipment. 6

8 IP grade is IP4 and belongs to water-splashing resistant equipment 1. Overview The SR7 is a constant-volume infusion pump. The advantages of this type of pump are high accuracy, stable flow rate and small amount of liquid used. It is especially suitable for infusion of emergency drugs such as Nipride, Dopamine and antibiotics. The pump can use 13 types of 20ml, 30ml or 50ml disposable syringe. Once the syringe is clamped on the pump, the pump will automatically identify the size of the syringe. In addition, the pump provides alarm functions to guarantee security and reliability of the infusion. 2. Operating principle The SR7 syringe infusion pump is a constant-volume pump. Drug volume output in schedule time will not be influenced by resistance in infusion line. When pressure reaches certain value, an overpressure alarm system set on the pump will trigger a sound and visual alarm and stops infusion. The pump actual output volume is consistent with the programmed volume. When any of the specified syringes is clamped on the pump, an identification system automatically adjust the corresponding rate. Just s et each required parameter, press STA RT key and the pump will begin operation. When the remaining liquid in the syringe reaches approximately 1.5ml, NEA.EMPTY message lights on the pump and intermittent sound alarm is triggered (sound alarm can be turned off by pressing the mute key). When the last 1.5ml liquid is over, EMPTY message lights on the pump and intermittent sound alarm is triggered. At this point the infusion is complete and the pump enters into KVO rate. If the infusion line is obstructed, the OCCLUSION message lights on the 7

9 pump and intermittent sound alarm is triggered. The pump automatically releases the system pressure. Pressing the Mute key returns the pump to previous infusion state. During operation, if power cord is disconnected, the pump triggers an intermittent sound alarm and light the Battery indicator in the front panel (alarming sound can be eliminated by pressing the Mute key) When the battery is near depleted, the Low Battery alarm triggers an intermittent visual and sound alarm. When the battery is fully depleted, the pump stops operation and alarm sound becomes continuous. 3. Technical Specifications? Flow rate: 20ml syringe: ml/h (press, 0.1ml/h increments; press,1ml/h increments ) 30ml syringe: ml/h (press, 0.1ml/h increments; press,1ml/h increments ) 50ml syringe: ml/h (press, 0.1ml/h increments; press,1ml/h increments)? Fast rate: 1200ml/h (50ml syringe) 600ml/h (30ml syringe) 399ml/h (20ml syringe)? Total volume: ml (0.1ml increments, above 1000ml 1ml increments)? Programmed volume: ml (press, 0.1ml/h increments; press 1ml/h increments)? Accuracy: =±2% ( Drive accuracy ±1%)? OCCLUSION pressure: 40N ± 10N (L) 60N ± 10N (H) 8

10 ? Alarm: near empty (NEA.EMPTY), empty, wrong clamping of syringe, wrong clamping of syringe plunger, malfunction, missing operation after power on, occlusion, total volume equal to preset volume, Low battery, battery depleted, AC power failure.? Power: AC: 115V or 230V, 50/60HZ Internal: DC12V The pump can run continuous ly for 4 hours at the rate of 5ml/h, using internal battery after it is charged for 16 hours.? Operating conditions: temperature: +5 to +40? ; RH: 20% to 90%? Transport and storage conditions: temperature: -40 to +55? ;? Dimensions: 307(L) 135(D) 128(H)mm RH: =95%? NET Weight: 2.1kg? Syringe: total 13 syringe brands can be used (refer to sheet 1) 9

11 10

12 4. Operation 4.1 Stand by and charge After connecting AC power, the AC indicator is light and the pump battery start to be charged 4.2 Power ON and Self-check To power on, press power key for 2 seconds, the pump do a system check for 3 seconds and is on for operation. Err indication on LED display indicates Pump malfunction. 4.3 Syringe Installation and Settings Connect the extension tube to the syringe with liquid. Remove all air from the infusion liquid and place the syringe flange into pump fixed groove. Press the rocking plate and the advancing head to move and adjust the position of the advancing head. Place the syringe plunger into the advancing head groove. Set all parameters, press FAST key then press and hold the Fast key until the liquid comes out of the scalp needle point. Insert needle tip into vein (artery) of patient and press START key, the pump then start programmed infusion. 4.4 Rate Setting After Power ON the Flow Rate LED display shows and it can be set using the 4 digit keys. fast digit setting key, decimal slow digit setting key. 11

13 Only in STOP mode the flow rate setting is available. After START all rate setting keys are locked. Set the desired Flow Rate and p ress the START infuse the whole liquid in the syringe or press the SELECT key to move to the next parameter. 4.5 Volume To Be Infused Setting Set the desired Volume to Be Infused LED Display by using the 4 digit keys. fast digit setting key, decimal slow digit setting key. Press START to start the programmed infusion or press the SELECT key to move to the next parameter. 4.6 Occlusion Pressure Setting Set Occlusion Pressure limit as high(h) or low(l). Default value is L. OCCL is displayed on the main LED display and L is displayed in the OCCLU.LIMIT display. Pressing slow digit setting key you may set the occlusion pressure limit to H or L. Press START to start the programmed infusion or press the SELECT key to move to the next parameter. 12

14 4.7 Selection of syringe brands The syringe Brand number is displayed as Choose syringe brand listed in table 1 pressing the digit select keys. No. The syringe Brand set is stored and is automatically set as default. Press START to start the programmed infusion. 4.8 Fast Infusion Fast infusion has two modes : Brand -01- Yusheng -02- LD -03- Weigao -04- Xinhua -05- TERUMO (japan) -06- Suyun -07- KDL -08- Shuangge -09- LY -10- B-D -11- JMS -12- Dragon heart -13- Dispo van Fast volume will not be added into total volume: At STOP condition, press the FAST key twice and hold. The Fast infusion starts and keeps as long as you hold the Fast key pressed. For 50ml syringe, Fast rate is 1200ml/h, for 30ml syringe is 600ml/h and for 20ml syringe is 399ml/h. The Fast rate is displayed in the LED digital display Fast Volume is added into Total volume At START condition, press the FAST and TOTAL key simultaneously. The Fast infusion occurs as long as you keep pressing the keys and the display shows the added volume. 13

15 4.9 Total Volume Press the Total key in STOP or START mode to display the Total Volume injected in the patient. Press Total volume key and mute key simultaneously to reset accumulated total volume to Alarms Near empty---when the syringe liquid reaches approximately 1.5ml, near empty alarm is triggered with visual and sound indication (NEA.EMPTY). Empty---when the syringe liquid finish, Empty syringe alarm (EMPTY) is triggered with visual and sound indication. The rate automatically changes to KVO rate 0.5ml/h. Occlusion---when needle tip or extension tube is blocked, the pump triggers an audio and visual alarm. The system pressure is released. If the clamp plate has not been pressed against the syringe or if syringe has been removed during operation, the pump will trigger an audio and visual alarm and will stop. If plunger of syringe has not been inserted into groove of advancing head, after start, the pump will trigger an audio and visual and will stop. Total volume---when total infused volume reaches programmed volume to be infused, the pump will trigger an audio alarm and stop. The LED display flashes the Rate and Total Volume values. To disable the audio alarm press the Mute key. Two minutes later, if no operation happened it will sound again. AC power failure--- if the pump is turned on and it is not connected to the AC power or if the power cord falls off during operation, the pump will trigger an audio and visual alarm. Press Mute to stop the audio alarm. The Battery indicator will stay light indicating the unit is running 14

16 on battery. Low battery ---when the internal battery voltage is low, the pump will trigger an audio and visual alarm (LOW-BATT). Press Mute to disable the audio alarm. The pump can run for approximately 30 minutes more in the internal battery. Depleted Battery Alarm--- when the battery if fully depleted, the pump will stop running and trigger a continuous audio alarm. No Operation Alarm---After power, if the pump is in the STOP mode and no any operation happens within 2 minutes, the pump triggers an audio alarm. Mute key---except for malfunction, battery depleted and syringe displaced alarm sounds can be cancelled by pressing mute key. Two minutes later, if no operation happened, the alarm will sound again Standard RS232 port The pump has a standard RS232 interface and two -way communication is available. Interface connector is present in the rear panel. Other equipment connected with RS232 interface shall comply with standard IEC60950: Pump Installation The pump may be clamped vertical or horizontal on supporting pole or bed level. 15

17 5. Troubleshooting Failure Possible reasons Action Inaccurate rate Low Battery alarm triggered shortly after startup When start infusion, blood return shows in the infusion line. Unsmooth move of advancing head Syringe flange does not enter into the groove of the syringe stool. Wrong syringe selection The battery was not charged after previous use or pump has not being used for a long time after previous charge Improper use of build-in battery, the battery is damaged. Before inserting the needle tip into vein, mechanism gap was not cancelled by pressing FAST key. Syringe flange does not enter into the groove of the syringe stool. Clamp block is stuck by liquid Re-install the syringe correctly Use syringe recommended in table 1 Recharge battery Replace battery Make sure no air is present in the infusion line. Press FAST key and push the blood back into vein. Re-install the syringe correctly Clean with alcohol 6. Maintenance Two AC fuses are located inside the pump. If the AC indicator does not light when the pump is connected to the AC mains, contact Digicare for technical support. Fuse specification is FAST; 0.5A; 250VAC; (5 20mm). 16

18 Clean the pump with a lint-free cloth lightly dumped with warm water and a standard disinfectant/detergent solution, before connecting the pump to a new patient, and periodica lly. Disinfectants which are known to be corrosive to metals must not be used. If the pump will be stored for an extended period of time it should be cleaned and the battery fully charged. Store it in a clean and dry location. During storage, once every 3 months perform functional tests and recharge the internal batteries. Before cleaning, always disconnect the pump from AC main power. Do not steam autoclave, ethylene oxide sterilize or immerse the pump in any liquid. Before using the pump, after long time without use, the battery shall be submitted to a charging-discharging inspection to avoid operation with a battery that is not getting charge and will not work under AC power-off situation. If the battery is not getting charge, it needs to be replaced. Contact Digicare for service. 7. Packing list 1 DigiPump SR7 1 clamp Holder 2 Allen screws for clamp holder 1 Allen tool for attaching clamp holder 1 Power Cable 1 Operator s Manual 17

19 8.WARRANTY TERMS & CONDITIONS DIGICARE BIOMEDICAL TECHNOLOGY, INC. covers all of their infusion pumps with a 1 year warranty: Infusion Pump DigiPump SR7: 1 year parts and labor Accessories: 90 days on accessories only DIGICARE BIOMEDICAL TECHNOLOGY, INC. will provide the necessary parts and labor to maintain the monitor (s) listed on the Warranty Certificate in a usable condition during the covered period. DIGICARE BIOMEDICAL TECHNOLOGY, INC. will, at its option, repair or replace any product which proves to be defective during the warranty period, if returned to the factory with prior authorization, transportation prepaid. Not covered by this agreement are repairs necessitated by any of the following conditions: 1 - Inadequate power or power failure. 2 - Neglect, abuse or misuse of equipment. 3 - Servicing of equipment by person s other than DIGICARE INC. 4 - Any unit opened or tampered with, without prior authorization. When returning an infusion pump for warranty repair, you must first contact DIGICARE BIOMEDICAL TECHNOLOGY, INC. to receive a Returned Goods Authorization Number (RGA #) that is to be clearly marked on top of the shipping carton. Please make sure that your company name, shipping address, area code and telephone number and person to contact is located in and/or on the box. ANY UNIT THAT IS RETURNED TO THE FACTORY WITHOUT AN RGA# WILL BE REFUSED. Model # Serial # Dealer Name: Date Equip. Purch.: / / Expiration Date: / / DIGICARE BIOMEDICAL TECHNOLOGY INC. 107 Commerce Road Boynton Beach, FL 33426, USA Phone: Fax: sales@digicarebiomedical.com 18

Accumate 2300 Volumetric Infusion Pump

Accumate 2300 Volumetric Infusion Pump Accumate 2300 Volumetric Infusion Pump Operating Manual www.wooyoungmed.com Log o Important This Operating Manual is for clinician use only. Do not permit patients to have access to this Operating Manual.

More information

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual Sentinel Enteral Feeding Pump Model: S-1000-SI Operating Manual CONTENTS 1. Introduction.. 2 2. Control Panel 5 3. Operating Instructions.. 6 4. Indicators and Alarms.. 9 5. Maintenance.. 10 6. Troubleshooting

More information

Cole-Parmer Pro-Spense

Cole-Parmer Pro-Spense Cole-Parmer Pro-Spense Portable Syringe Pump User s Manual Model #74905-44 Publication 5607-006-REV-A Contents Caution...2 Application Fields...2 Specifications...3 Operation Procedures: Keypad...4 Keypad

More information

Nimbus Flex Ambulatory Infusion Pump

Nimbus Flex Ambulatory Infusion Pump Nimbus Flex Ambulatory Infusion Pump Patient Manual Continuous Mode Infusions (Software Version v5.1.1) Read this entire manual prior to operating the Nimbus Ambulatory Infusion Pump. Failure to follow

More information

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0)

Unit 2, Rivington View Business Park, Station Road, Blackrod, Bolton BL6 5BN Tel: +44(0) The P900 enteral syringe pump has been designed to deliver small s of enteral feeds, accurately and safely, using enteral syringes, but cannot be used with IV syringes Unit 2, Rivington View Business Park,

More information

Quick Reference Guide

Quick Reference Guide Quick Reference Guide 3 Spike Set Cassette Inflow Connector Cassette Outflow Connector Return Line Latch Handle Patient Line Air Trap Keypad Cassette Customer Service Toll Free: 1-866-944-9992 Office:

More information

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS

More information

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A RemRest Tiers 1-3 900 Series Service Manual CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N 22054 Rev A Table of Contents IEC Symbols 3 SIZE 4.7" H X 8.6"

More information

User s Manual. Versaflo 200 Syringe Pump. For Veterinary Use Only

User s Manual. Versaflo 200 Syringe Pump. For Veterinary Use Only User s Manual For Veterinary Use Only Versaflo 200 Syringe Pump Midmark Corporation 60 Vista Drive, Box 286 Versailles, OH 45380-0286 Customer Service and Technical Service TEL: 1-800-MIDMARK (1-800-643-6275)

More information

NIKI T34 pump. Knowing your way around the NIKI T34 pump

NIKI T34 pump. Knowing your way around the NIKI T34 pump NIKI T34 pump Knowing your way around the NIKI T34 pump 2. Display Screen 3. Barrel clamp 4. Collar & Plunger Sensors 5. LED Indicator 1. Info Key 9. Up & Down arrow keys 8. YES (START)/ NO(STOP) keys

More information

Xenon Fiberoptic Lightsource

Xenon Fiberoptic Lightsource Xenon Fiberoptic Lightsource Operating Instructions for ASB-XE-175W Lightsource 2659A Pan American Frw N.E Albuquerque, New Mexico 87107 USA (English) Page 1 of 12 TABLE OF CONTENTS PAGE 1. INTRODUCTION

More information

Bio Lion Table Top Centrifuge XC-L5

Bio Lion Table Top Centrifuge XC-L5 Bio Lion Table Top Centrifuge XC-L5 Operation Manual Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting

More information

Eickemeyer Operating Manual Syringe Pump "Advanced"

Eickemeyer Operating Manual Syringe Pump Advanced Eickemeyer Contents Operating Manual Syringe Pump "Advanced" Chapter Page No. Rev.No.0.01 This manual has been compiled to users of the Syringe Pump in Installation, operation & routine maintenance. 1.

More information

Instructions For Use VATEA. Endodontic Irrigation Device

Instructions For Use VATEA. Endodontic Irrigation Device Instructions For Use VATEA Endodontic Irrigation Device VATEA Irrigation System Instructions for use 1. Indications for use The VATEA system is intended to be attached to dental handpieces to deliver irrigation

More information

Bio Lion Table Top Centrifuge XC-H165

Bio Lion Table Top Centrifuge XC-H165 Bio Lion Table Top Centrifuge XC-H165 Operation Manual Table of contents Section Specification Page 1 Pictures Page 2-3 Starting Safety information Page 4 Set up Page 5-7 Operation Page 7-8 Troubleshooting

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-17B & AEU-17BV2 Implant / Surgery Systems TABLE OF CONTENTS: Specifications........................i Introduction.........................1 Package Contents....................1

More information

Medi-Temp III FW601 Blood/Fluid Warmer Operator s Manual/Service Manual P/N /04

Medi-Temp III FW601 Blood/Fluid Warmer Operator s Manual/Service Manual P/N /04 Medi-Temp III FW601 Blood/Fluid Warmer Operator s Manual/Service Manual P/N 12195-000 3/04 Table of Contents Sec Topic Page 1.0 Indications for Use... 1 2.0 Product Description... 2 3.0 Instructions for

More information

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:

More information

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide

BodyGuardTM 323. BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump. Patient Guide BodyGuardTM 323 BodyGuard 323 Multi-Therapy Ambulatory Infusion Pump Patient Guide How to Use This Booklet This booklet gives you information about how to use your BodyGuard 323 infusion pump. It supplements

More information

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority DCell Suction Model DM10-001 Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com

More information

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale

Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale Model 3400KL / 3401KL / 3400KG / 3400KG-C Digital Wet Diaper / Lap Sponge / Organ Scale 3400KL / 3400KG / 3400KG-C 3401KL User Instructions PELSTAR, LLC 9500 West 55 th St. McCook, IL 60525-7110 USA www.homscales.com

More information

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH OPERATING MANUAL POWER DRIVE SYSTEM Cat. No. 400005 525-1300-00 RevH System components Symbol Definitions Qty Description Catalog Number 1 Power Drive System 300106 1 Controller 300108 1 Cutter Drive

More information

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance TM ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance Scale Users Guide ISHTAA SCALES INC., INDIA www.ishtaascales.com 14 Content 1. Technical Data... 1 2. Installation... 2 3. Controls

More information

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority VX-2 Model 2310 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com techsupport@sscor.com

More information

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on User Manual Charger for LTO Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d emploi Manual

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E Digital Apex Locator ipex OPERATION MANUAL 0197 OM-E0285E The EU directive 93/42/EEC was applied in the design and production of this medical device. Thank you for purchasing the ipex. This is apex locator.

More information

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority Quickdraw Model 2400 Series Clearing The Airway Is Our #1 Priority Operating Instructions & Maintenance Manual, INC. 11064 Randall Street Sun Valley, CA 91352 USA www.sscor.com Email: marketing@sscor.com

More information

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso TIC 300 PRO High Energy Tic Tracer Non Contact AC Voltage Detector

More information

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT BT403 A Geno Technology, Inc. (USA) brand name BT-300 Power Supply Cat. No. BT403 1-800-628-7730 1-314-991-6034 info@btlabsystems.com WARNING... 3 SAFETY INFORMATION... 3 ENVIRONMENTAL CONDITIONS... 4

More information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English

More information

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems OPERATION AND MAINTENANCE INSTRUCTION MANUAL AEU-707A & AEU-707AV2 Implant / Surgery Systems TABLE OF CONTENTS: Introduction.........................1 Package Contents....................1 Setting Up the

More information

6 Bay Battery Charger Operation Manual

6 Bay Battery Charger Operation Manual 6 Bay Battery Charger Operation Manual Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216 USA Customer Service: 904 737 7611 Toll Free 877 677 2832 EC REP RMS UK, Ltd. 28 Trinity Road

More information

User Manual Rittal PMC UPS 6kVA

User Manual Rittal PMC UPS 6kVA User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...

More information

B-RAD Select USER MANUAL TABLE OF CONTENTS

B-RAD Select USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13

SURGICAL POWER & ACCESSORIES. Rx Only PM-X00-710/PM-X IR-12.13 SURGICAL POWER & ACCESSORIES Rx Only PM-X00-710/PM-X00-715-IR-12.13 Table of Contents Introduction Page 4 Intended Use Page 4 Warnings Page 5 Cautions Page 5 Notes Page 5 Explanation of Symbols Page 6

More information

portable ac/dc suction pump USER S MANUAL ITEM # 18605

portable ac/dc suction pump USER S MANUAL ITEM # 18605 portable ac/dc suction pump USER S MANUAL ITEM # 18605 index 1 1. Safety Information...2-4 2. AC Power Source...3 3. Electrical...3-4 4. Introduction...4 5. Illustration of Important Parts...5 6. Set-Up...6

More information

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance... -1- Table of Contents Introduction 3 Package Contents 4 Classifications.. 5 Designated Symbols 6 Safety Instructions 7 Instrument Components 9 Installation.,12 Focusing..14 Operating Instructions..15 Charts

More information

Language specific user manuals are available on

Language specific user manuals are available on User Manual WEB Charger for LiFePO 4 Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d

More information

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:

More information

SurePower Battery Pack Guide

SurePower Battery Pack Guide ? SurePower Battery Pack Guide 9650-0536-01 Rev. B The issue date for the SurePower Battery Pack Guide (9650-0536-01 Rev. B) is September, 2010. If more than three years have elapsed since the issue date,

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL PAGE 2 WARNING Do not install, maintain or operate this equipment without first reading and understanding

More information

Ambulatory Syringe Pump Operation Manual

Ambulatory Syringe Pump Operation Manual McKinley T34 Ambulatory Syringe Pump Operation Manual IMPORTANT NOTICE: McKinley strongly recommends that this manual is read by every user of the T34 syringe Pump and that they comprehensively understand

More information

Quick Guide. brite Advanced Retail scale

Quick Guide. brite Advanced Retail scale Quick Guide brite Advanced Retail scale 2 METTLER TOLEDO Quick Guide brite Advanced Contents 1 Your new retail scale...4 1.1 Safety instructions...4 1.2 Further documents...4 1.3 Maintenance...4 1.4 Intended

More information

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500 NANOPAC-300 & 500 Power Supply Instruction manual NANOPAC-300 & NANOPAC-500 Version 01C Feb 5th, 2014 1 Packing list NANOPAC-300 or 500-1x NANOPAC-300 Power Supply or NANOPAC-500-1x Power Cord - 1x Instruction

More information

User Manual Stealth s Power Tilt

User Manual Stealth s Power Tilt User Manual Stealth s Power Tilt Copyright 2014 Stealth Products, Inc. Copyright 2014 Stealth Products, Inc. All rights reserved. Published by Stealth Products, Inc. November 7, 2014 P45D61R1 Customer

More information

User Manual Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...

More information

5.2 PRE-OPERATION PROCEDURE WARRANTY

5.2 PRE-OPERATION PROCEDURE WARRANTY 4/02 Form #314 OPERATING INSTRUCTIONS MODELS DM-210A, 220A, 230A DIGITAL MULTIMETER PLEASE READ THESE OPERATING INSTRUCTIONS CAREFULLY Misuse and or abuse of these instruments cannot be prevented by any

More information

UTILITY INPUT MAINS OUTLET

UTILITY INPUT MAINS OUTLET THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS, KEEP THIS MANUAL HANDY FOR FUTURE REFERENCE. INSTALLATION AND OPERATION Before installation, please read and understand the following instructions: Inspect

More information

Syringe Driver Introduction. Christine Hull & Anita Webb Staff Nurses, Hospice in the Home 2015

Syringe Driver Introduction. Christine Hull & Anita Webb Staff Nurses, Hospice in the Home 2015 Syringe Driver Introduction Christine Hull & Anita Webb Staff Nurses, Hospice in the Home 2015 Aims and Objectives To gain an understanding of using the McKinleyT34 syringe driver. To review knowledge

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

18VDC ESB6 Series Cordless Screwdrivers Operation Manual 18VDC ESB6 Series Cordless Screwdrivers Screwdriver Models : ESB6-8, ESB6-12, ESB6-15, ESB6-22 CAUTION - Please read, understand, and follow all operating and safety instructions in this manual before

More information

Operating and Service Manual

Operating and Service Manual Part No.: MAN755_080214 Page 1 of 16 by S Instruments, Inc. Model SR755 / SR755L Wheelchair Scale Operating and Service Manual Serial Numbers: 1514+ Part No.: MAN755_080214 Page 2 of 16 TABLE OF CONTENTS

More information

Manual KREBS Viscometer PCE-RVI 5

Manual KREBS Viscometer PCE-RVI 5 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Model 605 Portable Aspirator

Model 605 Portable Aspirator Model 605 Portable Aspirator CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. #P1000 Rev. 11/02 Table of Contents Specifications 2 Important Parts of the VacuMax

More information

SurePower TM II Battery Pack Guide

SurePower TM II Battery Pack Guide TM SurePower TM II Battery Pack Guide? 1:00+ 2:00+ 3:00+ TM 9650-000840-01 Rev. B The issue date for the SurePower II Battery Pack Guide (REF 9650-000840-01 Rev. B) is December, 2012. If more than three

More information

FreeGo. pump. Training Manual. Freedom for life

FreeGo. pump. Training Manual. Freedom for life FreeGo pump Training Manual Freedom for life Contents Section 1 Set-up What you need Set up the FreeGo pump table top stand 2 Preparation Prepare the FreeGo pump Plug in and turn on Page 1 2 3 4 3 The

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information

Operator Manual of Guangzhou Huaxi Medical Technology Co., Ltd. JORVET INFUSION PUMP J1060 OPERATOR MANUAL

Operator Manual of Guangzhou Huaxi Medical Technology Co., Ltd. JORVET INFUSION PUMP J1060 OPERATOR MANUAL Operator Manual of Guangzhou Huaxi Medical Technology Co., Ltd. JORVET INFUSION PUMP J1060 OPERATOR MANUAL Please read manual before operating your JorVet Infusion Pump Jorgensen Laboratories 1450 N. Van

More information

User Manual. Solar Charge Controller 3KW

User Manual. Solar Charge Controller 3KW User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5

More information

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station AC Irrigation and Propagation Controllers 5004-I Four Station, 5006-I and 5006-IP Six Station I N S T R U C T I O N M A N U A L Table of contents Introduction 1 1. Specifications 1 2. Controller Mounting

More information

FLEXIFLO QUANTUM Enteral Pump

FLEXIFLO QUANTUM Enteral Pump FLEXIFLO QUANTUM Enteral Pump Operating Manual For Enteral Use Only Not for IV Use CONTENTS Pump Characteristics................................................ 3 Pediatric Use......................................................

More information

CADD -Solis VIP Ambulatory Infusion Pump Model 2120

CADD -Solis VIP Ambulatory Infusion Pump Model 2120 CADD -Solis VIP Ambulatory Infusion Pump Model 2120 Clinician Guide Contents I Description of the CADD -Solis VIP Pump... 4 Indications... 4 Pump Diagram... 5 Pump Descriptions... 5 Keypad... 6 I Pump

More information

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

OWNER'S MANUAL. Royal Sovereign International Inc.   RET Desk Series OWNER'S MANUAL RET Desk Series Read all instructions carefully before use. For any Customer Support needs please choose the Customer Support tab on www.royalsovereign.com Royal Sovereign International

More information

freedom through lightweight solutions

freedom through lightweight solutions freedom through lightweight solutions Mangar Inc. 3020 Legacy Dr. Suit 100-301 Plano, TX 75023 tel: 1-800-901-5269 www.mangarusa.com Mangar International Presteigne Powys LD8 2UF Wales, UK tel: +44(0)1544

More information

LED-HL2-CMP LED Headlight System Operation Manual

LED-HL2-CMP LED Headlight System Operation Manual LED-HL2-CMP LED Headlight System Operation Manual Manufactured for: Cardio Medical Products, Inc. 385 Franklin Avenue, Suite L Rockaway, NJ 07866 USA Customer Service: 800-227-3633 info@cardiomedicalproducts.com

More information

BodyGuard 121 Twins Infusion System Operator Manual

BodyGuard 121 Twins Infusion System Operator Manual BodyGuard 121 Twins Infusion System Operator Manual 0344 Manufacturer: Caesarea Medical Electronics GmbH. 23 Staufenburg st. 72805 Lichtenstein, Germany +800-323-575-00 E-mail: Sales@cme-infusion.com www.cme-infusion.com

More information

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL SAVE THIS MANUAL You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts

More information

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.

More information

Owner s Guide CARS & CA4B5

Owner s Guide CARS & CA4B5 PROFESSIONAL SERIES Owner s Guide For Model: CARS & CA4B5 Deluxe Vehicle Remote Start and Keyless Entry System IMPORTANT NOTE: The operation of the Security and Convenience System as described in this

More information

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080 Befour, Inc. 102 Progress Drive Saukville, WI 53080 Phone: 262-284-5150 Toll Free: 1-800-367-7109 Fax: 262-284-5966 Email: mail@befour.com www.befour.com 2014 Befour, Inc. Rev.1 HTR-202 Portable Digital

More information

Stealth Power i-tilt

Stealth Power i-tilt Power Tilts OWNERS MANUAL Stealth Power i-tilt User Manual and Maintenance Guide for Stealth s i-tilt Customer Satisfaction 1.0 Stealth Products strives for 100% customer satisfaction. Your complete satisfaction

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions. Instruction Manual ENGLISH Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions. BIBO QUICK START GUIDE Insert the bibo Mouthpiece into

More information

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9 Single and 8-channel Electronic Pipettes Operation Manual Version: 2.9 Table of Contents 1. Safety Precautions...1 1.1. Operation Safety Precautions...1 1.2. Battery Safety...1 2. General Description...3

More information

Operating instruction and technical description

Operating instruction and technical description Operating instruction and technical description EV Simulator for charging devices with charging plug / charging coupler / charging cable type 1 and type 2 as service case Photo: EV simulator/tester with

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

Triple Output Power Supply

Triple Output Power Supply Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 2831D 4 ½ Digit True RMS Digital Multimeter 1 1. PRODUCT DESCRIPTION 1-1. Introduction Thank you

More information

Language specific user manuals are available on

Language specific user manuals are available on User Manual WEB Charger for Lead Acid Batteries EN User Manual Language specific user manuals are available on www.mascot.no/downloads/usermanuals Bruksanvisning Käyttöohjeet Bedienungsanleitung Mode d

More information

BodyGuard 323 Infusion Pump System Operator Manual

BodyGuard 323 Infusion Pump System Operator Manual . BodyGuard 323 Infusion ump System Operator Manual 0344 Manufacturer: Caesarea Medical Electronics Ltd. European address: Staufenburgstr. 23 Lichtenstein.O.B. 1248 Lichtenstein 72805 Germany International

More information

Model 8000XL OPERATOR MANUAL

Model 8000XL OPERATOR MANUAL Model 8000XL OPERATOR MANUAL DORAN SCALES, INC. 1315 PARAMOUNT PKWY. BATAVIA, IL 60510 1-800-262-6844 FAX: (630) 879-0073 http://www.doranscales.com MANUAL REVISION: 1.0 MAN0191 10/3/2005 INTRODUCTION

More information

Model 1693, 1694 Switching DC Power Supply

Model 1693, 1694 Switching DC Power Supply Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases

More information

High Tension Spark Igniter (HTSI)

High Tension Spark Igniter (HTSI) High Tension Spark Igniter (HTSI) User Manual Publication INTRODUCTION This manual contains information for the High Tension Spark Igniter (HTSI) from Forney Corporation, 16479 North Dallas Parkway, Suite

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

SmartVent. Instructions for Use Version 4 (Dec 2009)

SmartVent. Instructions for Use Version 4 (Dec 2009) SmartVent Instructions for Use Version 4 (Dec 2009) SmartVent is a radioaerosol delivery system that has been developed to give unrivalled performance for lung ventilation scintigraphy. Consistent, excellent

More information

Owner s Guide. ca5354

Owner s Guide. ca5354 PROFESSIONAL SERIES Owner s Guide for models: ca5354 Deluxe Vehicle Remote Start System with 900Mhz 2 Way Confirming LED Remote Control IMPORTANT NOTE: The operation of the Security and Convenience System

More information

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual 18VDC ESB6-X Series Cordless Screwdrivers Screwdriver Models : ESB6-X3.5, ESB6-X3.5F, ESB6-X5F ESB6-X6, ESB6-X9, ESB6-X12 CAUTION - Please read, understand, and follow all operating and safety instructions

More information

Operating Instructions

Operating Instructions Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3

More information

User Manual. 3/1 10K~30K Online UPS

User Manual. 3/1 10K~30K Online UPS User Manual 3/1 10K~30K Online UPS Uninterruptible Power Supply System Version: 1.7 Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read

More information

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation

More information

Model 1672, 1673 Triple Output Power Supply

Model 1672, 1673 Triple Output Power Supply Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be observed during all phases

More information

CRONO S-PID 50 Ambulatory infusion pump

CRONO S-PID 50 Ambulatory infusion pump CRONO S-PID 50 Ambulatory infusion pump NEW MODEL USER GUIDE Canè S.p.A. Medical Technology Via Cuorgnè 42/a 10098 Rivoli (TO) Italy Tel.+39 011 9574872 - Fax +39 011 9598880 www.canespa.it - mailbox@canespa.it

More information

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual Reach ins, Freeezers & Refrigerators Installation & Operation Manual BSR23 BSF23 BSR49 BSF49 BSR72 BSF72 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Visit us on the web at www.blueairinc.com

More information

LED FLASHER GND CONTROL FPC4N

LED FLASHER GND CONTROL FPC4N LED FLASHER GND CONTROL FPC4N Installation/Operations Manual FPC4N Table of Contents Applicable Models... 2 Introduction... 2 General Warnings... 2 Unpacking &Pre-Installation Check... 3 Installation &

More information

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL SAVE THIS MANUAL You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts

More information

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual IQS300 Series Quasi-Sine Inverter Installation & Operation Manual INTRODUCTION State of the Art MOSFET technology coupled with unique Soft-Start circuitry guarantees reliable operation. The ON-OFF switch

More information

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US MV Series Motors Operation & Parts Manual Models M3V, M5V, M5V-US Introduction This manual pertains to drum pump motors MV Series. Finish Thompson, Inc. thanks you for choosing our products. We believe

More information

Instruction for Use (IFU)

Instruction for Use (IFU) Instruction for Use (IFU) QPORT1700 Rev. A5 February 2016 PROPRIETARY AND CONFIDENTIAL Copyright 2015 by Quality in Flow (QinFlow) Ltd. All rights reserved. No part of this manual may be reproduced or

More information