USER MANUAL 2AMDI584IPDBS

Size: px
Start display at page:

Download "USER MANUAL 2AMDI584IPDBS"

Transcription

1 USER MANUAL 2AMDI584IPDBS SUBJECT INDEX: DESCRIPTION TECHNICAL SPECIFICATION DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE OPERATION MODES PUSH MODE WHITE TUNABLE + BLUETOOTH (DEFAULT) PUSH MODE 2 SEPARATED CHANNELS + BLUETOOTH DALI MODE 2 CHANNELS BLUETOOTH CONTROL PARAMETERS CONFIGURATION Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 1

2 DIMMER DUE CANALI MULTIPROTOCOLLO C.C. Bluetooth IoT Light DUAL CHANNELS MULTIPROTOCOL DIMMER C.C. Bluetooth IoT Light CARATTERISTICHE TECNICHE TECHNICAL NOTES - Dimmer due canali con Uscita in Corrente PWM. - Range di alimentazione: 8-53V DC. - Uscita in Corrente PWM con corrente da 170mA a 1050mA (54,6W a 52VDC per canale). - Controllabile tramite app Android/iOS IOT LIGHT. - Ingressi di Controllo: Pulsante isolato x2, DALI x1, Bluetooth LE x1. - Circuito Stampato UL. - Classe di protezione: IP20. - Dimensioni Standard 40x80x24.45 mm. - Dimensioni con Accessori 40x100x24.45 mm. - Protezione da inversione di polarità. - Protezione circuito aperto. - Protezione da picchi tensione. - Protezione da sovratemperatura. - Protezione corto circuito. PULSANTE N/O ISOLATO N/O insulated switch - Dual channels Dimmers with Output Current PWM. - Input Range: 8-53V DC. - Output Current PWM with current from 170mA a 1050mA (54,6W at 52VDC each channel). - Controllable with Android/iOS app IOT LIGHT. - Input Controls: Insulated Push button x2, DALI x1, Bluetooth LE x1. - Printed Circuit UL. - Protection Class: IP20. - Standard Dimension 40x80x24.45 mm. - Dimension with accessories 40x100x24.45 mm. - Reverse polarity protection. - Open circuit protection. - Surge voltage protection. - Over temperature protection. - Short circuit protection. INGRESSI DI CONTROLLO - CONTROL INPUTS DALI 0-10V;1-10V PULSANTE NO (isolato) PUSH NO (INSULATED) Bluetooth LE POTENZIOMETRO LINEARE 100K Linear Potentiometer X1 - X2 X1 - CORRENTE MAX IN USCITA (*) MAX OUTPUT CURRENT Da 170mA a 1050mA / From 170mA to 1050mA Dimmer due canali con Uscita in Corrente PWM. Range di alimentazione: 8-53V DC. Uscita in Corrente PWM con corrente da 170mA a 1050mA (54.6W a 52V DC per canale). Controllabile tramite app Android/iOS IOT LIGHT. Per impostare le correnti di uscita occorre dotarsi di interfaccia 2AMIN N venduta separatamente. Corrente di default 350mA. Per impostare il fade e la curva logaritmica/lineare di uscita occorre dotarsi di interfaccia 2AMIN N venduta separatamente, le modalità di funzionamento vengono riconosciute e impostate automaticamente dal dispositivo senza bisogno di interfaccia esterna. Vedi manuale d uso. dual channels Dimmers with Output Current PWM. Input Range: 8-53V DC. Output Current PWM with current from 170mA a 1050mA (54.6W at 52V DC each channel). Controllable with Android/iOS app IOT LIGHT. In order to set the output current you will need the 2AMIN N interface sold separately. Default current 350mA. In order to set the fade output and the logarithmic or linear output you will need the 2AMIN N interface sold separately, the other working modes are automatically detected by the device. Please refer to user manual. Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 2

3 CODICE CODE TENSIONE IN INGRESSO INPUT VOLTAGE CORRENTE USCITA (MAX) (MAX) OUTPUT CURRENT n. CANALI IN USCITA n. OUTPUT CHANNELS POTENZA MAX IN USCITA per canale MAX OUTPUT POWER each channel INGRESSI DI CONTROLLO CONTROL INPUTS SCATOLA CASE DIM. DIM. 2AMDI584IPDBS 8-53V DC da 170mA a 1050mA From 170mA to 1050mA W a 52V DC Pulsante isolato x2, DALI x1 BLUETOOTH LE x1 Push insulated x2, DALI x1 BLUETOOTH LE x1 SI 40x80 mm h 24,45 mm Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 3

4 DEVICE POWER SUPPLY AND CONNECTION TO THE LED MODULE POWER SUPPLY CONNECTION DIAGRAM AND LED 2AMDI584IPDBS - FIGURE N. 1 The 2AMDI584IPDBS dimmer has to be powered according to the polarity showed in FIG. 1 through the DC IN (+ and -) terminals. In case the power supply polarity is inverted no damage will be caused to the device. The LED (LED PWR) positioned on the circuit board indicates the presence of power supply. The LED (LED DIM) shows the dimming level of the output. The LED load connection has to be made by using the OUT (L+ CH1- e CH2- ) terminals. Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 4

5 OPERATION MODE PUSH MODE WHITE TUNABLE + BLUETOOTH (DEFAULT) PUSH WIRING DIAGRAM 2AMDI584IPDBS - FIGURE N. 2 In order to activate this mode of control/operation it is necessary connect between the DALI/PUSH1 terminals and between the PUSH2 terminals a signal in direct or alternating voltage (DC voltage range:10 265V, AC Vac 50 65Hz) interrupted by a normally open button (N.O.). No polarization is needed for the input signal The maximum current absorbed by the PUSH interface is about 2mA. PUSH1 input drive the colore temperature. PUSH2 input drive the intensity. The dimmer saves the output position in order to restore the set level in case of power failure (preset). PUSH 2 interface operation Single Click (rapid press (<1sec)) - Turns on or off the output (ON/OFF). Double Click (rapid press (<1sec)) - Sets maximum brightness (output= 100%) Long Press (long press (>1sec)) - If the dimmer is in OFF position, it sets the output to the minimum value (default= 1%) - If the dimmer is in ON position, the long press enables the output dimming (up/down). PUSH 1 interface operation Long Press (long press (>1sec)) - Change color temperature ( example Hot -> Cold e Cold -> Hot) Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 5

6 PUSH MODE 2 SEPARATED CHANNELS + BLUETOOTH PUSH WIRING DIAGRAM 2AMDI584IPDBS - FIGURE N. 3 In order to activate this mode of control/operation it is necessary connect between the DALI/PUSH1 terminals and between the PUSH2 terminals a signal in direct or alternating voltage (DC voltage range:10 265V, AC Vac 50 65Hz) interrupted by a normally open button (N.O.). No polarization is needed for the input signal. The maximum current absorbed by the PUSH interface is about 2mA. The dimmer saves the output position in order to restore the set level in case of power failure (preset). PUSH interface operation Single Click (rapid press (<1sec)) - Turns on or off the output (ON/OFF). Double Click (rapid press (<1sec)) - Sets maximum brightness (output= 100%) Long Press (long press (>1sec)) - If the dimmer is in OFF position, it sets the output to the minimum value (default= 1%) - If the dimmer is in ON position, the long press enables the output dimming (up/down). Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 6

7 DALI MODE 2 CHANNELS DALI WIRING DIAGRAM 2AMDI584IPDBS - FIGURE N. 4 In order to activate this mode of control/operation it is necessary connect the DALI bus between the DALI/PUSH1 inputs. On the first reception of a properly formatted DALI package the dimmer is configured in DALI mode. Once configured in DALI mode and disconnected from the DALI bus the dimmer switches to the POWER ON LEVEL mode set through DALI bus. The maximum current absorbed by the DALI bus is about 2mA. The device is seen by DALI bus like 2 indipendent devices. The DALI bus can control each channel dimming level separately. ATTENTION IN THIS MODE THE BLE (Bluetooth) CONTROL IS FORBIDDEN. Below you can find the implemented standard commands: DIRECT ARC POWER OFF UP DOWN STEP UP STEP DOWN RECALL MAX LEVEL RECALL MIN LEVEL STEP DOWN AND OFF ON AND STEP UP GO TO SCENE (0-15) RESET STORE ACTUAL LEVEL IN THE DTR STORE THE DTR AS MAX LEVEL STORE THE DTR AS MIN LEVEL STORE THE DTR AS SYSTEM FAILURE LEVEL STORE THE DTR AS POWER ON LEVEL STORE THE DTR AS FADE TIME STORE THE DTR AS FADE RATE STORE THE DTR AS SCENE (0-15) Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 7

8 REMOVE FROM SCENE (0-15) ADD TO GROUP (0-15) REMOVE FROM GROUP (0-15) STORE DTR AS SHORT ADDRESS QUERY STATUS QUERY BALLAST QUERY LAMP POWER ON QUERY LIMIT ERROR QUERY RESET STATE QUERY MISSING SHORT ADDRESS QUERY VERSION NUMBER QUERY DEVICE TYPE QUERY PHISICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL QUERY MIN LEVEL QUERY POWER ON LEVEL QUERY SYSTEM FAILURE LEVEL QUERY FADE TIME/FADE RATE QUERY SCENE LEVEL (0-15) QUERY GROUPS (0-7) QUERY GROUPS (8-15) QUERY RANDOM ADDRESS H QUERY RANDOM ADDRESS M QUERY RANDOM ADDRESS L Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 8

9 BLUETOOTH CONTROL In order to activate this mode of control/operation it is necessary to install the Necto Group app on the Android or ios device that you want to use for the 2AMDI584IPDBS dimmer control. The implemented features are: Switching on and off and the brightness level control of each individual light point. Ability to group together and control several light points with just a simple command. Creation and recall of your favourite lighting sceneries. The system management from a single simplified user interface. THE BLUETOOTH LE CONNECTION DOES NOT REQUIRE PAIRING PROCEDURE Necto Group App features (* depending on the device only some functions may be available) Dimmer management at 1 or 4 channels with different modes of operation: - Mono channel - 4 synchronized channels - RGB (3 channels or 3 zones) - RGB + White (4 channels or 4 zones) - Dynamic White Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 9

10 In order to install the app on your Apple or Android device you need to scan the desired QRCode to be automatically redirected to the product data sheet of the IoT Light application. As an alternative you can download the app by clicking on one of two links below: Apple: Android: Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 10

11 PARAMETERS CONFIGURATION CLICK ON THE WANTED CONFIGURATION TO VIEW 2AMIN N PROGRAMMER IMAGE Reset Configuration A B C D Reset ON ON ON ON ON ON ON ON ON ON ON ON ON ON Dimming Curve Configuration A B C D Logarithmic OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Linear OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON PWM Configuration A B C D PWM Standard OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF PWM Inverted OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON Fade Configuration A B C D Fade Off OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Fade On OFF OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON Change Mode Configuration A B C D Input PUSH (NOT ISOLATED) OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF white tunable + Bluetooth Input PUSH (NOT ISOLATED) OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON 2 independent channels + Bluetooth Input DALI 2 channels OFF ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF Current Configuration A B C D ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 182 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON 195 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF 210 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON 222 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF 235 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON 250 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF 260 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON 270 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF 290 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON 300 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF 315 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON 330 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF 345 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON 355 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 370 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON 385 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF Necto Group S.r.l Padova ma - Via Canada, 8 - ITALY OFF - T +39 ON049 OFF OFF F OFF OFF OFF OFFinfo@nectogroup.com ON OFF ON pag. 11

12 355 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF 370 ma OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON ON 385 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF 395 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON 410 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF 425 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON 438 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF 450 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON 465 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF 480 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON ON ON 490 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF 500 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON 515 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF 530 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON 545 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF 560 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF ON 575 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON OFF 585 ma OFF ON OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON 600 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF 615 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF ON 626 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON OFF 640 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF OFF ON ON 653 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF OFF 667 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON OFF ON 680 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON OFF 694 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON 707 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF 721 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF ON 734 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF 748 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON ON 761 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF OFF 775 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON OFF ON 788 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON OFF 802 ma OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON ON ON ON 815 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF OFF 829 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF OFF ON 840 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON OFF 855 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF OFF ON ON 870 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF OFF 880 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON OFF ON 895 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF 910 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON OFF ON ON ON 920 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF OFF 935 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON 950 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF ON OFF 965 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON OFF ON ON 975 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF OFF 990 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON OFF ON 1020 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON ON OFF 1050 ma OFF ON OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON Necto Group S.r.l Padova - Via Canada, 8 - ITALY - T F info@nectogroup.com pag. 12

enerbox Pannello di controllo per 2 pompe (optional) Control panel for 2 pumps (optional) Pannello di controllo standard Standard control panel

enerbox Pannello di controllo per 2 pompe (optional) Control panel for 2 pumps (optional) Pannello di controllo standard Standard control panel enerbox on on enerbox enerbox control pumps 1 11 AUT AUT 0 0 MAN MAN Pannello di controllo standard Standard control panel Pannello di controllo per 2 pompe (optional) Control panel for 2 pumps (optional)

More information

INVERTER TRIFASE HEAVY DUTY

INVERTER TRIFASE HEAVY DUTY INVERTER TRIFASE HEAVY DUTY Serie di inverter per utilizzi professionali 24h al giorno. Per attività commerciali e artigianali, utenze isolate ed ovunque si voglia ottenere l autonomia energetica anche

More information

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

RM B. Features. Drive Model Number Scheme. A RM6 Product Series Features RM6 series are suitable for constant and variable torque loads (mixer, conveyor, fan, pump, etc.) Overload capacity with 150% drive s rated output current for 1 min can sustain heavy load conditions

More information

ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX DG/S x DALI-Gateway Basic ABB i-bus KNX DG/S x.64.1.1 DALI-Gateway Basic The lamps are variably controlled via KNX per DALI output via Broadcast (all lamps jointly) 16 lighting groups 64 individual lamps 16 scenes 64 self-contained

More information

Quick Reference Guide. English EN Español ES Français FR Nederlands NL

Quick Reference Guide. English EN Español ES Français FR Nederlands NL Quick Reference Guide English EN Español ES Français FR Nederlands NL Rogue R1 FX-B QRG EN About This The Rogue R1 FX-B Quick Reference Guide (QRG) has basic product information such as connection, mounting,

More information

Incassi a parete - Recessed wall-mounted luminaires THUNDER110. arcluce.it. thunder

Incassi a parete - Recessed wall-mounted luminaires THUNDER110. arcluce.it. thunder Incassi a parete - Recessed wall-mounted luminaires arcluce.it thunder 181 Predisposto per controllo via BLE, per dettagli contattare l azienda. Suitable for BLE control device, for details consult the

More information

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323

More information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information Segment Terminal Fused, with Diagnostics 24VDC Segment Terminal module is used to create a protected partial circuit (segment circuit) within the main circuit. It is not used to supply power and has no

More information

ISTRUZIONI DI MONTAGGIO / MOUNTING INSTRUCTIONS

ISTRUZIONI DI MONTAGGIO / MOUNTING INSTRUCTIONS Energon - Regolatore Digitale per Fan Coil Energon - Fan Coil Digital Controller NR9000 ISTRUZIONI DI MONTAGGIO / MOUNTING INSTRUCTIONS APPLICAZIONE ED USO NR9000 è un regolatore digitale per unità terminali

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION Electrical Energy Storage Tester EEST-511-S Semi-Automatic Charge-Discharge Battery Bench 1 channel 50 V / 100A (Ni-CD, Pb, Ni-Mh, Li-ion...) TECHNICAL DESCRIPTION To buy, sell, rent or trade-in this product

More information

Servomotori Brushless serie BT2 tensioni 230 e 400 Vac coppie nominali da 2,2 a 7,5 Nm

Servomotori Brushless serie BT2 tensioni 230 e 400 Vac coppie nominali da 2,2 a 7,5 Nm Servomotori Brushless serie BT2 tensioni 230 e 400 Vac coppie nominali da 2,2 a 7,5 Nm ITE Industrialtecnoelettrica Srl by TEM-ELECTRIC-MOTORS DATI MOTORE Motor ratings SIMBOLI Symbols UNITÀ Units SERIE

More information

BOX A3 TEST R. Bocconi. REL. DATE R.T. Check and Approval

BOX A3 TEST R. Bocconi. REL. DATE R.T. Check and Approval BOX A3 TEST 7 20-02-2018 R. Bocconi REL. DATE R.T. Check and Approval INDEX 1 - FOREWORD...... Page 3 2 - BOX A3 TEST FOR HYDRAULIC LIFTS... Page 3 2.1 GENERAL OPERATION... Page 3 2.2 HOW THE CHECK OF

More information

Phoenix Inverter

Phoenix Inverter Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information

Application book Construction and Agricultural machines. Ultrasonic & Inductive Sensors. Ultrasonic & Proximity Sensors

Application book Construction and Agricultural machines. Ultrasonic & Inductive Sensors. Ultrasonic & Proximity Sensors Application book Construction and Agricultural machines Ultrasonic & Inductive Sensors Ultrasonic & Proximity Sensors Catalogue Cod. CAT3E001269501 Application book - Ultrasonic & Inductive Sensors - English

More information

Amperis battery regenerator

Amperis battery regenerator Amperis battery regenerator Universal Battery Charger/Discharger/Analyzer Amperis battery regenerator Quick regenerations Expanded lifespan of batteries The Most Energy Efficient technology available.

More information

GTS 15/25/40/50/60/75/90/120A

GTS 15/25/40/50/60/75/90/120A GTS 15/25/40/50/60/75/90/120A POWER SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac Main applications Plastic extrusion lines and injection presses Packing and packaging machines Polymerization and production

More information

ATTENTION. Magic Zone Bluetooth Command Remote Installation Instructions

ATTENTION. Magic Zone Bluetooth Command Remote Installation Instructions Magic Zone Bluetooth Command Remote Installation Instructions We thank you for purchasing the Custom Dynamics Magic Zone Command Remote. Our products utilize the latest technology and high quality components

More information

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) With central control inputs, front button and various operating modes and functions General purpose, user-friendly electronic pushbutton dimmer for

More information

DURATAPE TM RGB IP20 INDOOR

DURATAPE TM RGB IP20 INDOOR e Static Indoor Key Features Flexible flat conductor strip with High Output Red 625nm, Green: 520nm, Blue: 465nm LEDs, RGB colors can be used together with White LED to create different tone of White or

More information

REV lubrication systems PEGPEO Electropumps for progressive systems

REV lubrication systems PEGPEO Electropumps for progressive systems lubrication systems PEG/PEO 520-540 - 580 PEGPEO 520-540-580 Electropumps for progressive systems INDEX OF CONTENTS Applications and description 3 Technical data 4 Reservoir 5 Electric motor 6 Electropump

More information

DURATAPE TM RGB IP66 OUTDOOR

DURATAPE TM RGB IP66 OUTDOOR Key Features Flexible flat conductor strip with High Output Red 625nm, Green: 520nm, Blue: 465nm LEDs, RGB colors Ideal for exterior cove, under-counter/cabinet, lighting accents Complete with encased

More information

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives REGAL-BELOIT SpinMaster Volts/Hertz Constant Torque, Micro Inverter Applications: Constant torque or constant horsepower applications. Typical applications include conveyors, packaging machinery, machine

More information

Transformers for Low-voltage Halogen Incandescent Lamps

Transformers for Low-voltage Halogen Incandescent Lamps Transformers for Low-voltage Halogen Incandescent Lamps Independent electronic converters 10 14 With DLI interface 14 Electronic built-in converters 15 17 Potentiometer and dimmers 18 Electromagnetic safety

More information

Wind display type WSDI-2

Wind display type WSDI-2 USER s MANUAL/INSTALLATION NOTE Wind display type WSDI-2 Input and wiring Mounting Document no.: 4189350032C Table of contents 1. INTRODUCTION... 3 UNPACKING... 3 2. INPUT AND WIRING INSTRUCTION... 4 3.

More information

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:

More information

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC Inline Power Terminal With Fuse and Diagnostics Data Sheet 5569C 02/2003 # # $ ' ) The IB IL 24 PWR IN/F-D and IB IL 24 PWR IN/F-D-PAC only differ in the scope

More information

TPART 1 PRODUCT SPECIFICATIONS...1.

TPART 1 PRODUCT SPECIFICATIONS...1. 7 APPENDIX 7. MAINTENANCE 7 7 No. Item Name 4 5 6 7 8 9 0 4 5 6 7 8 9 0 4 5 6 7 8 9 0 4 5 6 Hanger Wireless Receiver Top cover Fix board of wireless Receiver. Lens. Plastic cover for fixing lens. Plastic

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

CB Type Intelligent Battery Chargers

CB Type Intelligent Battery Chargers CB Type Intelligent Battery Chargers With the CB Battery Charger Line, Altech offers a highly reliable battery management solution. Operating at single phase Input Voltages of 115230277 VAC, the devices

More information

Moduli LED LED modules

Moduli LED LED modules Moduli LED LED modules Moduli LED LED modules Moduli LED disponibili in diverse configurazioni per alimentazione e per settore di utilizzo. I moduli LED per applicazioni office sono caratterizzati da alte

More information

TWIGGY T1, TUBULAR 1" LENS TUNABLE WHITE 24VDC SYSTEM, 90+CRI

TWIGGY T1, TUBULAR 1 LENS TUNABLE WHITE 24VDC SYSTEM, 90+CRI TWIGGY T1, TUBULAR 1" LENS TUNABLE WHITE 24VDC SYSTEM, 90+CRI MADE IN THE USA 0.39" (.99cm) 1.4" (3.6cm) 4.6" (11.7cm) To Remote Power Supply 1" (2.5cm) 12" to 120" (30.5cm - 304.8cm) To Remote Power Supply

More information

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets 1 1/6 Introduction 1/7 Switches and pushbuttons 1/13 Shutter/blind controls 1/19 Socket outlets 1/25 International plug-and-socket devices 1/26 Lighting controls 1/29 Motion detectors 1/31 Room temperature

More information

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type>

MANBLAN Hybrid Powered Landscape Lights SL C-00-5 <Assembly Type> MANBLAN Hybrid Powered Landscape Lights SL03-13024C-00-5 1 MANBLAN Hybrid Powered Landscape Lights SL03-13024C-00-5 INDEX 1. Design Overview 3-4 2. Wind Turbine 5 3. Solar Panel 6 4. LED

More information

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External

T P M S. Multi Wheel Bluetooth. Tire Pressure Monitoring System. User Manual. Model: External T P M S Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External Table of Contents 1. PRODUCT INTRODUCTION... 2 2. NOTICE... 2 3. BLE TPMS SPECIFICATION... 3 4. BLE TPMS PACKAGE...

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

Please Read Over This Manual Before Operating The Light Fixture

Please Read Over This Manual Before Operating The Light Fixture USER MANUAL Please Read Over This Manual Before Operating The Light Fixture ABLE OF CONTENTS TPART PRODUCT SPECIFICATIONS... 7 APPENDIX 7. MAINTENANCE.--TECHNICAL SPECIFICATIONS....--DIMENSIONS....-- SAFETY

More information

HIGH POWER SOLENOID DRIVER 1

HIGH POWER SOLENOID DRIVER 1 Elactis SA Switzerland Phone : Fax : E-mail : Web : +41 22 364 65 85 +41 22 364 65 87 info@elactis.com http://www.elactis.com HIGH POWER SOLENOID DRIVER 1 ADRV1012K 1 This datasheet is a preliminary description.

More information

L300P Inverter Specifications

L300P Inverter Specifications L300P Inverter Specifications Tables for 200V class inverters Note that General Specifications on page 1 9 covers all L300P inverters, followed by footnotes for all specifications tables. Seven 200V models

More information

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External T P M S Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External Table of Contents 1. PRODUCT INTRODUCTION... 2 2. NOTICE... 2 3. BLE TPMS SPECIFICATION... 3 4. BLE TPMS PACKAGE...

More information

DURATAPE TM RGBW IP20 INDOOR

DURATAPE TM RGBW IP20 INDOOR e Static Indoor Key Features Flexible flat conductor strip with High Output Red 625nm, Green: 520nm, Blue: 465nm LEDs, RGB colors can be used together with White LED to create different tone of White or

More information

R 159. Duty cycle. ED 100%; ED 60%(90 C) Direzione del fluido Unidirezionale Flow direction Unidirectional Diametro di passaggio DN 8 mm.

R 159. Duty cycle. ED 100%; ED 60%(90 C) Direzione del fluido Unidirezionale Flow direction Unidirectional Diametro di passaggio DN 8 mm. Elettrovalvola Serie R R 159 Rpe s.r.l. Via S. Ambrogio, 3 22070 Carbonate (CO) Italy Tel. +39 0331832515 Fax +39 0331832501 www.rpesrl.it CLASSIFICAZIONE CLASSIFICATION Tipologia Semplice Type Single

More information

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21

Table of Contents. Product Registration 18 FAQ 19 Troubleshooting 20 Customer Support / Warranty 21 Table of Contents Product Overview 01 / 02 Introduction / Warnings 03 / 04 Battery Operation / Battery Maintenance 05 / 07 Battery Installation 05 Charging the Battery 06 Master Code Programming 08 Remote

More information

HOT MELT RESIN MOLDING TECHNOLOGIES SYSTEM'S STRUCTURE

HOT MELT RESIN MOLDING TECHNOLOGIES SYSTEM'S STRUCTURE HOT MELT RESIN MOLDING TECHNOLOGIES SYSTEM'S STRUCTURE Suitable Mold Project and Realization Molding Quality Correct Molding Equipment Raw Material in compliance with the requirements of the finished product

More information

Frequently Asked Questions

Frequently Asked Questions Decora Digital Device Questions Do all Decora Digital devices have Bluetooth Technology? DDMX1, DDS15 and DDL06-BT, DDE06, DD710 and DDF01 are all Bluetooth enabled devices with timer capabilities. DD00R-DL,

More information

MP8000 BLUETOOTH OVERLOAD RELAY FAQ

MP8000 BLUETOOTH OVERLOAD RELAY FAQ MP8000 BLUETOOTH OVERLOAD RELAY FAQ Patent Pending MP8000 SPECIFICATIONS What can I protect with the In what voltage range can the MP8000 operate? What amp range does the MP8000 have? Do I need external

More information

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp VS1MX AC Micro Drive 1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp & Controls 115 VAC 230 VAC 230 VAC 460 VAC 1 Phase - 50/60 Hz 1 Phase - 50/60 Hz 3 Phase - 50/60 Hz 3 Phase - 50/60 Hz Applications:

More information

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO.

Max Load. Max. Load. 100W 3-50VDC mA > 90% < 20% > 0.95 RFID P/N: XXXXXXXXXX CERTIFIED TO CSA STD. C22.2 NO. WIDTH DRIVEN HEIGHT MAGNITUDE LIGHTING AFLEX LINEAR DIMMABLE E465183 DIM DOWN TO 0.1% CLASS P CLASS 2 QUICK SPECS The AFlex Series of Constant Current Programmable LED Drivers offers high efficiency, smooth

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces

COOLEDGE TILE TUNABLE WHITE - SPECIFICATIONS SYSTEM OVERVIEW SPECIFICATION GENERAL FEATURES. DATE NOTE For Luminous Surfaces PROJECT REFERENCE SPECIFIED BY QUANTITY DATE NOTE For Luminous Surfaces SYSTEM OVERVIEW Replicate natural light both in scale and through dynamic changes in color temperature 1 TILE Tunable 2 TILE Tunable

More information

Air Lift Performance 3S

Air Lift Performance 3S Air Lift Performance 3S Control System P A T E N T E D AD-955 (011807) ERN 8639 USER GUIDE For maximum effectiveness and safety, please read these instructions completely before operating. Failure to read

More information

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL

GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL rev gp-a 7.0.00 GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available

More information

ASYN205B Central Synchronizing Controller

ASYN205B Central Synchronizing Controller ASYN205B Central Synchronizing Controller Function 3 phase active power transducer, one auxiliary analog Genset power control Genset voltage frequency control Multi-gensets power balance control Selectional

More information

3-phase motors Vector-Speed Synchronous motors

3-phase motors Vector-Speed Synchronous motors SQ SERIES Dati Generali/General Data Forma costruttiva / Mounting IM 2001 (B35) Protezione motore / Motor Protection type SQC IP 54 (IP 55 ) 2) Equilibratura / Balancing grado R R degree grad R Isolamento

More information

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual Model 905 IV16 DC Input Module. Page 2 Operations Manual Table of Contents Table of Contents...2 Module Installation Procedure...3

More information

Oil/Air Cooler Units Standard series - Accessories

Oil/Air Cooler Units Standard series - Accessories Oil/Air Cooler Units Standard series - Accessories In many industrial applications the Oil/Air coolers require accessories, either controlling or protecting the cooler and the hydraulic system. The accessories

More information

POW72V35A/BMS CHARGER SPECIFICATION

POW72V35A/BMS CHARGER SPECIFICATION POW72V35A/BMS CHARGER SPECIFICATION 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage 47-63 Hz frequency 1-4 Inrush current < 100 A A

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

VA R I A B L E S P E E D D RIVE NANO

VA R I A B L E S P E E D D RIVE NANO VA R I A B L E S P E E D D RIVE NANO the brothers: NEO-WIFI tutorial https://www.youtube.com/watch?v=huxj47p_qxo&feature=youtu.be NEO-COMP https://www.youtube.com/watch?v=y8yhvdyirka NEO-VENT https://www.youtube.com/watch?v=dbcvtzzgyam&feature=youtu.be

More information

D R C- 4 0 s e r i e s

D R C- 4 0 s e r i e s LPS Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 Features Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Battery low protection /

More information

J1000. Compact Inverter Series.

J1000. Compact Inverter Series. J1000 Compact Inverter Series www.yaskawa.eu.com Focus on Application Customer orientation and application focus two attributes of machine equipment YASKAWA offers with its J1000 compact inverter drive

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO DIM C 45 W Combined emergency lighting LED Driver Product description Dimmable built-in LED Driver Emergency lighting LED Driver with DALI interface and automatic test function For self-contained emergency

More information

Daymak Drive Application ios. User Guide

Daymak Drive Application ios. User Guide Daymak Drive Application ios User Guide Thank You Thank you for your purchase of our Daymak product. By choosing to utilize an electric vehicle, you are actively doing your part to reduce your carbon footprint.

More information

Digital Time Switches

Digital Time Switches Digital Time Switches Precise time programming for Daily/Weekly/Pulse switching 25 ON/OFF programs Weekend Exclusion (FRI SAT or SAT SUN) and Weekly OFF programming LED Indication of Relay status & 12/24

More information

CIRRUS CEILING SQUARE 1 WITH REMOTE POWER

CIRRUS CEILING SQUARE 1 WITH REMOTE POWER Diffused Square 1 (Actual Size) Description Cirrus Ceiling S1 is a linear LED fixture that offers direct light in a clean, contemporary style. Cirrus is available in various increments from 12" to 720"

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

Fig.306F (DN50-150) Pressure Independent Control Valve (PICV)

Fig.306F (DN50-150) Pressure Independent Control Valve (PICV) Installation, Operating and Maintenance Instructions Fig.306F (DN50-150) Pressure Independent Control Valve (PICV) GENERAL NOTES The Hattersley Fig.306F: Can be used in variable volume heating and chilled

More information

MY ENERGICA Reference guide

MY ENERGICA Reference guide MY ENERGICA Reference guide My Energica_Rev04_ENG Introduction My Energica is the application that allows you to connect through Bluetooth our Energica bikes to either Apple or Android devices. The application

More information

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications

OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications www.osram.us/optotronic OPTOTRONIC LED Power Supply OTi 30W Emergency Driver Technical Specifications Electrical Specifications Input General Information Item Number 57403 & 57404 Type Constant Current,

More information

CB Type Intelligent Battery Chargers

CB Type Intelligent Battery Chargers CB Type Intelligent Battery Chargers With the CB Battery Charger Line, Altech offers a highly reliable battery management solution. Operating at single phase Input Voltages of 11520277 VAC, the devices

More information

Continental Hydraulics Installation Manual CEM-AA-A

Continental Hydraulics Installation Manual CEM-AA-A Continental Hydraulics Installation Manual CEM-AA-A Description: This power amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to proportional

More information

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO T5 PC, 220 240 V 50/60 Hz Linear fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For T5 fluorescent lamps Low-profile casing (21 x 30 mm cross-section)

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;

More information

BT1S. DATI MOTORE Motor ratings. Cat.gen.ed.SEP12.rev.A. SERIE Series. Symbols UNITÀ SIMBOLI. Units. COPPIA Torque Nm 0,5

BT1S. DATI MOTORE Motor ratings. Cat.gen.ed.SEP12.rev.A. SERIE Series. Symbols UNITÀ SIMBOLI. Units. COPPIA Torque Nm 0,5 DATI MOTORE Motor ratings SIMBOLI Symbols UNITÀ Units SERIE BT1S COPPIA Torque Nm 0,5 TIPO DI AVVOLGIMENTO Winding type - - 3022 COPPIA CONT.ROTORE BLOC.DT65 C IN ARIA Cont. torque lock.rotor dt65 C in

More information

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation! Demand Switch NEFA20 Plus Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Protective Covers DIN Mounting Rail NEFA20 Plus Mounting Rail Spacer Warning

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps Product description oise-free precise control via signal or switchdim CELMA energy class A1 1) Interfaces switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer setting Automatically

More information

BT3M. DATI MOTORE Motor ratings. Cat.gen.ed.SEP12.rev.A. SERIE Series. Symbols UNITÀ SIMBOLI. Units. COPPIA Torque Nm 12,5

BT3M. DATI MOTORE Motor ratings. Cat.gen.ed.SEP12.rev.A. SERIE Series. Symbols UNITÀ SIMBOLI. Units. COPPIA Torque Nm 12,5 DATI MOTORE Motor ratings SIMBOLI Symbols UNITÀ Units SERIE BT3M COPPIA Torque Nm 12,5 TIPO DI AVVOLGIMENTO Winding type - - 3038 COPPIA CONT.ROTORE BLOC.DT65 C IN ARIA Cont. torque lock.rotor dt65 C in

More information

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications

OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications www.osram.us/optotronic OPTOTRONIC LED Power Supply OTi 50W Emergency Driver - Technical Specifications GENERAL INFORMATION Item Number 57405 & 57406 ELECTRICAL SPECIFICATIONS Input Input Voltage (VAC)

More information

Apparecchi da incasso a soffitto - Recessed downlights QUANTUM130. arcluce.it. quantum

Apparecchi da incasso a soffitto - Recessed downlights QUANTUM130. arcluce.it. quantum Apparecchi da incasso a soffitto - Recessed downlights QUANTUM130 arcluce.it quantum 323 Predisposto per controllo via BLE, per dettagli contattare l azienda. Suitable for BLE control device, for details

More information

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY

More information

BIDIRECTIONAL DC/DC CONVERTER

BIDIRECTIONAL DC/DC CONVERTER Features: Description: The 3,500 Watt 48S14.250BC Bidirectional non-isolated DC/DC converter provides a complete solution for invehicle power distribution in 12V/48V battery configurations for a variety

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

Installation Instructions MX LED Enhanced Color Adjustable

Installation Instructions MX LED Enhanced Color Adjustable Installation Instructions 1 of 5 MX Enhanced Color Adjustable Risk of electrical shock. Disconnect power before servicing or installing luminaire. Risk of injury or damage. will fail if not installed properly.

More information

EGT-100 Operations and Installation Manual

EGT-100 Operations and Installation Manual Page 1 of 11 All specification subject to change 2002-2005 EGT-100 Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual with any

More information

All In one uninterruptible power supply solutions

All In one uninterruptible power supply solutions All In one uninterruptible power supply solutions For the life of your systems with Battery Care concept Integrated Electronic Solution Yet another strong proposition from Adelsystem, result of the continuing

More information

Entrematic SBU-BBU20-BBU65

Entrematic SBU-BBU20-BBU65 IP2254 2017-03-31 Entrematic -BBU20-BBU65 Istruzioni kit batterie Batteries kit instructions Inclusi nel kit / included in the kit: Descrizione / Description Controllore di carica montato su staffa Charge

More information

CIRRUS SUSPENSION WITH RECTANGULAR 1 LENS WITH REMOTE POWER, END FEED

CIRRUS SUSPENSION WITH RECTANGULAR 1 LENS WITH REMOTE POWER, END FEED Diffused Rectangular 1 Lens Description Cirrus R1 Suspension with Remote Power is a linear LED fixture that offers direct light in a clean, contemporary style. Cirrus R1 is available in various increments

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

FAIL-SAFE CONTROL VALVES. Fast Electrically Actuated Control Valves

FAIL-SAFE CONTROL VALVES. Fast Electrically Actuated Control Valves Fast Electrically Actuated Control Valves FAIL-SAFE CONTROL VALVES FOR MODULATION CONTROL OF INSTANTANEOUS WATER HEATERS & HEAT EXCHANGER APPLICATIONS ARIA Overview At 2mm/sec travel speed (12 seconds/inch),

More information

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T. ALIEM USER MANUAL 2 19-04-2018 R. Bocconi REV. DATE Checked and Approved R. T. PAGE INTENTIONALLY LEFT BLANK 2 ALIEM 1000 USER'S MANUAL Version 2 dated 19-04-2018 1 INTRODUCTION ALIEM 1000 is an emergency

More information

User Manual WatchPower App

User Manual WatchPower App User Manual WatchPower App Management Software for Inverter Table of Contents 1. Introduction... 1 2. WatchPower App Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software Install... 1 2.3.

More information

VASCO. Variable Speed Controller ENGLISH

VASCO. Variable Speed Controller ENGLISH VASCO Variable Speed Controller ENGLISH Variable Speed Controller VASCO is a purpose-built family of variable frequency drives, designed to control and protect pumping systems based on changing pump speed.

More information

HomeWorks QS RF C L Hybrid seetouch Keypads

HomeWorks QS RF C L Hybrid seetouch Keypads HomeWorks QS RF C L Hybrid seetouch Keypads function as a dimmer and keypad combined into a single device. C L Hybrid Keypads are great for retro fit applications since they eliminate the need to install

More information

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions

Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester. Charge & Testing. Integrated Electronic Solutions Battery Care the new Battery Charger Philosophy Battery Charger and Battery Tester Charge & Testing Integrated Electronic Solutions Connect Multimediality The new ADELSystem platform communication ADELBus

More information

Model Number AC-50CD1.4APNZ AC-50CD1.4APBNZ

Model Number AC-50CD1.4APNZ AC-50CD1.4APBNZ ELECTRICAL SPECIFICATIONS: Programmable, Digital, Wide-Range Ajustable Current & Dimming Type TL Rated Constant Current LED Driver Model Number AC-5CD.4APNZ Input Voltage: 2-277V Input Frequency: 5/6Hz

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features Product Guide ALC-PRM-VFC Ceiling Mounted Photocell Overview The ALC-PRM-VFC photocell will turn lighting on when the ambient light falls below a preset level. The lighting will then be turned off when

More information

EcoSystemR Multiple Control Input Ballasts

EcoSystemR Multiple Control Input Ballasts EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,

More information

Safety Control HR1S-AC. Safety Relay HR1S-AC

Safety Control HR1S-AC. Safety Relay HR1S-AC HRS-AC Safety Relay HRS-AC Key features: NC or 2NC safety input type, such as E-Stops or Interlock Switches EN ISO 3849- PLe, Safety Cat 3 compliant, and EN 6206 SIL 3 Fault diagnosis function with dual

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information