LTG Air-Water Systems
|
|
- Grant Owens
- 5 years ago
- Views:
Transcription
1 Technical Brochure LTG Air-Water Systems Active chilled beams HDF Ceiling installation
2 Active chilled beams HDF, ceiling installation LTG Comfort Air Technology Air-Water-Systems Content Page Product overview 3 Series HDF Series HDF Regulation system 25 Air Diffusers Air Distribution Notes Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Tolerances according to DIN ISO 2768-vL. For the outlet grille special tolerances stated in the drawing apply. Straightness and twist tolerances for extruded aluminium profiles according to DIN EN The surface finish is designed to meet the requirements for applications in buildings - room climate according to DIN 1946 part 2. Other requirements on request. The actual specifications are are available as a word document at your local distributor or at E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 2 of 25
3 Active chilled beams HDF, ceiling installation The Induction Principle Air flowing through a nozzle forms a free jet. It induces the surrounding air layer along at its edges and thus enlarges the flowing air volume. This induction takes place within the induction device. A special construction entrains room air (secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh air (primary air) the supply air then returns to the room for a comfortable climate. LTG induction units of the latest generation are energy-efficient and can be operated and demandcontrolled with LTG SmartFlow technology. Two-pipe system The unit has only one heat exchanger through which chilled water flows for cooling and hot water for heating. Therefore, it is only possible to either heat or cool within a single water circuit. Four-pipe system The unit has two separate water systems, one for heating, the other one for cooling. Therefore, chilled and hot water always remain separate. The four-pipe system fulfills all requirements on varying loads and small control zones. Induction Principle Product overview View of units Series HDF-300 Series HDF-600 Application Water system Options Installation Modularceiling systemforventilationusingprocessedoutsideairandindividualtemperaturecontrol of rooms based on the induction principle, i.e. without the use of a fan. Dry cooling without dehumidification and condensate drainage. 2-pipe system, 4-pipe system Low installation height Fresh air unit Blind diffuser In T-bar, grid and plasterboard ceilings Flanged, recessed Fresh air unit Blind diffuser Supply air pattern 2-way diffusion 2-way diffusion, 4-way diffusion E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 3 of 25
4 Active chilled beams series HDF-300, ceiling installation View of unit Active chilled beam series HDF-600 Application The active chilled beam type HDF has been designed as a modular ceiling unit to condition rooms with regarding humidity and temperature based on the induction principle, i.e. without the use of a fan. The active chilled beam is designed for dry cooling without dehumidification and condensate drainage. Installation, positioning Its low construction height allows installation in false ceilings with limited space. The reduced width and the selectable length allow an easy integration in 300 or 312 mm grid ceilings. Unit lengths from 1200 mm to band installation (within a 300 mm grid system) may be realized. It is designed to provide complete separation from the ceiling cavity and to suppress sound transmission from adjacent rooms (telephony sound insulation). Functional Principle Room air humidity is controlled through the centrally dehumidified supply air avoiding involuntary dehumidification in the active chilled beam. The 2-pipe systemmay be usedfor either cooling only or change-over operation with cooling/ reheating. The 4-pipe system with independent water circuits automatically switches from cooling to heating and vice versa. During operation, 100% of the primary air is pretreated fresh air from a central fresh air unit. It assures the use-dependent basic ventilation using outside air, e.g. in conformity with DIN EN or DIN EN recommendations. Through uniformly arranged nozzles over the entire unit length, the primary air is led in an injector-type diffuser which induces secondary air. Depending on the room load, this secondary air is either heated or cooled in a 2-pipe or 4-pipe heat exchanger. The supply air, a mixture of primary and secondary air, is distributed into the room in two directions via ceiling jets. Advantages Low primary air pressures between 50 and 100 Pa - Low-noise operation; sound pressure may be selected to remain below 35 db(a) - High secondary (water-side) capacity of up to 350 W/m - Easy air flow balance of the units within a single duct run - Energy-efficient operation Flexible nozzle design - Selection for fixed primary pressure possible - Primary air flow may be selected according to room use between 20 and 100 m 3 /h/m - Non combustible metal nozzles Low installation height mm standard mm type HDF-300/N Efficient heat exchanger - High heating capacity even with low warm water supply temperatures (e.g. 30 _C) - High cooling capacity with high chilled water supply temperatures (e.g. 16 _C) - Low water flow rates, designed for a temperature difference of 3 K Flexible connection of media - Primary air connection with NW 100 on the long side (standard) - Water connections on unit top surface for convenient pipe connections from left or right Designed for easy maintenance design - Easily removable secondary air inlet grille - No protective air filter required for the heat exchanger Perfect integration in false ceilings - Width 295 mm, recessed installation - Width 319 mm, flanged installation Pleasing design - Air diffuser construction of aluminium profiles - Visible surfaces powder coated e.g. similar to RAL Secondary air inlet grille out of expanded metal panel (free area > 63%) - Secondary air grille in the form of a perforated sheet metal optional (square perforation) Simplified commissioning - Measuring point to determine the air flow rate (standard) - Pressure balancing with a perforated sheet metal balancing damper E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 4 of 25
5 Active chilled beams series HDF-300, ceiling installation Design - 4-pipe system for cooling and heating - 2-pipe system for cooling or heating - Flanged installation or recessed installation - Balancing damper KLI Options - HDF-N - low installation height - HDF-L - fresh air unit - HDF-B - blind diffuser Materials and Finish Primary air duct of galvanized sheet steel, nozzle duct and induction nozzles of black coated sheet steel, 1 mm thick, longitudinal profiles of aluminium, either anodized or powder coated similar to RAL. Secondary airinlet grille of galvanized sheet metal, powder coated like the air diffuser frame. Accessories - Return air connection NW 100, integrated in the diffuser frame - Blind unit extension, to be used to match specific lengths required on site - Sheet metal console to mount valves on unit top-side or end side - Thermal control valves - Flexible water connections with 12 mm quick coupling Dimensions See drawings on the next pages. Air diffuser frame, flanged installation 295 L ,5 1, ,5 Air diffuser frame, recessed installation L , ,5 L 1 Size L 1 recessed [mm] L 2 flanged [mm] L 3 [mm] L 4 [mm] L5 [mm] Weight [kg] E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 5 of 25
6 Active chilled beams series HDF-i300, ceiling installation Dimensions Model with return air connection DN 100 Front view Top view Front view L Ø 100 Suspension points with insulating spacers for M8 threaded rods 4 x Ø L 5 L 2 Standard model Top view L Suspension points with insulating spacers for M8 threaded rods 4 x Ø L 4 L 2 Lateral view 4-pipe-unit shown: air diffuser frame flanged installation Lateral view 2-pipe-unit shown: air diffuser frame recessed installation Primary air Connection for quick coupling Primary air Connection for quick coupling xØ12 2xØ12 80 Socket DN 100 Measuring device for flow rate determination Socket DN 100 Air outlet Air outlet Air outlet Air outlet Air inlet Air inlet E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 6 of 25
7 Active chilled beams series HDF-300, ceiling installation Dimensions type HDF-300/N - low installation height Front view 67 Lateral view Ø L 3 Suspension points with insulating spacers for M8 threaded rods 4 x Ø Measuring device for flow rate determination 8 Top view DN L 1 Dimensions type HDF-300/L - fresh air unit Lateral view Front view L Suspension points with insulating spacers for M8 threaded rods 4 x Ø Measuring device for flow rate determination Dimensions type HDF-300/B - blind diffuser Top view DN 100 L 1 Lateral view Front view L 1 L 3 Suspension points with insulating spacers for M8 threaded rods 295 Top view E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 7 of 25
8 Active chilled beams series HDF-300, ceiling installation Technical data size 1200, 4-pipe system - cooling and heating p Q P / t / t w ok / p w Q h / t / Technical data size 1500, 4-pipe system - cooling and heating p Q P / t / t w ok / p w Q h / t / Technical data size 1800, 4-pipe system - cooling and heating p Q P / t / t w ok / p w Q h / t / Q h 2) Q h 2) Q h 2) w oh / p w 80 / 2.1 w oh / p w 100 / 2.5 w oh / p w 120 / 2.9 E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 8 of 25
9 Active chilled beams series HDF-300, ceiling installation Technical data size 2100, 4-pipe-system - cooling and heating p Q P / t / t w ok / p w Q h / t / Q h 2) The chart shows selection examples. Selection software is available for other flow rates, primary pressures, temperatures and water flow rates. Data are based on a unit including a secondary air inlet grille 63 % free area. Correction for other water flow rates see page 12 et sqq. Water supply temperature: 16 _C Air inlet temperature or return air temperature: 26 _C 2) Water supply temperature: 40 _C Air inlet temperature or return air temperature: 22 _C w oh / p w 130 / 3.0 Legend - primary air flow rate (± 3 %) p - static pressure at the primary air connection - sound pressure level at 18 m 2 Sabine (± 3 db) - sound power level (± 3 db) Q P - air-side cooling capacity (primary air ± 3 %) - water-side cooling capacity (secondary ± 6 %) t - temperature difference between air inlet and water supply w ok - standard water flow rate (cooling) p w - water-side pressure loss Q h - water-side heating capacity (secondary ± 6 %) w oh - standard water flow rate (heating) E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 9 of 25
10 Active chilled beams series HDF-300, ceiling installation Technical data size 1200, 2-pipe system - cooling or heating p Q P / t / t w ok / p w Q h / t / Technical data size 1500, 2-pipe system - cooling or heating p Q P / t / t w ok / p w Q h / t Q h 2) Q h 2) / Technical data size 1800, 2-pipe system - cooling or heating p Q P / t / t w ok / p w Q h / t Q h 2) / w oh / p w 80 / 2.1 w oh / p w 100 / 2.5 w oh / p w 120 / 2.9 E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 10 of 25
11 Active chilled beams series HDF-300, ceiling installation Technical data size 2100, 2-pipe system - cooling or heating p Q P / t / t w ok / p w Q h / t / Q h 2) The chart shows selection examples. Selection software is available for other flow rates, primary pressures, temperatures and water flow rates. Data are based on the unit including a secondary air inlet grille 63 % free area. Correction for other flow rates see pages 12 et sqq. Water supply temperature: 16 _C Air inlet temperature or return air temperature: 26 _C 2) Water supply temperature: 40 _C Air inlet temperature or return air temperature: 22 _C w oh / p w 130 / 3.0 Legend - primary air flow rate (± 3 %) p - static pressure at the primary air connection - sound pressure level at 18 m 2 Sabine (± 3 db) - sound power level(± 3 db) Q P - air-side cooling capacity (primary air ± 3%) - water-side cooling capacity (secondary ± 6%) t - temperature difference between air inlet and water supply w ok - standard water flow rate (cooling) p w - water-side pressure loss Q h - water-side heating capacity (secondary ± 6%) w oh - standard water flow rate (heating) E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 11 of 25
12 Active chilled beams series HDF-300, ceiling installation Cooling capacity with different water flow rates Cooling capacity in % of the nominal capacity pipe 2-pipe Water flow rate in % of the standard water flow rate Heating capacity with different water flow rates Heating capacity in % of the nominal capacity Q h pipe 2-pipe Water flow rate in % of the standard water flow rate E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 12 of 25
13 Active chilled beams series HDF-300, ceiling-installation Water-side pressure loss with different water flow rates, 4-pipe system - cooling 10 Water-side pressure loss [kpa] 1 Size 1200 Size 1500 Size 1800 Size Water flow rate w [kg/h] Water-side pressure loss with different water flow rates, 4-pipe system - heating 10 Water-side pressure loss [kpa] 1 Size 1200 Size 1500 Size 1800 Size Water flow rate w [kg/h] E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 13 of 25
14 Active chilled beams series HDF-300, ceiling installation Water-side pressure loss with different water flow rates, 2-pipe system - cooling or heating Water-side pressure loss [kpa] 10 1 Size 1200 Size 1500 Size 1800 Size Water flow rate w [kg/h] E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 14 of 25
15 Active chilled beams series HDF-300, ceiling installation Nomenclature HDF-300 / / 2 / 1200 / 45 / 80 / A / S / 600 / RAL... ( (2) (3) (4) (5) (6) (7) (8) (9) (10) ( Series HDF-300 = HDF-300 (2) Type = Standard installation height N = Low installation height L = Fresh air unit B = Blind diffuser (3) Heat exchanger 2 = 2-pipe system 4 = 4-pipe system (4) Size 1200 = = = = = 2400 (5) Primary air flow rate 45 = E.g. 45 m³/h (6) Primary air pressure 80 = E.g. 80 Pa (7) Return air spigot A = With return air spigot O = Without return air spigot (8) Secondary air grille S = Expanded metal L = Perforated sheet steel (9) Ceiling grid (diffuser) 300 = 300 (10) Surface of diffuser RAL... = Coated similar to RAL, indicate RAL-colour E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 15 of 25
16 Active chilled beams series HDF-600, ceiling installation View of unit Active chilled beam typ HDF-600/4A, 4-way diffusion Application The active chilled beam HDF is a ceiling-mounted unit for ventilation and individual temperature control based on the induction principle, i.e. without the use of a fan, using processed outside air. The active chilled beamis designed for dry cooling without dehumidification and condensate drainage. Installation, positioning The low construction height (200 mm) allows installation in false ceilings with limited space. The active chilled beam is suitable for installation in grid ceilings measuring 600 x 600 mm, 600 x 1200 mm, 625 x 625 mm or 625 x 1250 mm and may be positioned in or adjacent to T-bar profiles. With grid and plasterboard ceilings, installation may be recessed or flanged. Functional Principle During operation, the primary air is 100% pretreated outside air from a central central AHU. It assures the use-dependent basic ventilation rate using outside air, e.g. in conformity with DIN EN or DIN EN recommendations. Through uniformly arranged nozzles over the entire unit length, the primary air is led in an injector-type diffuser which induces secondary air. Depending on the room load, this secondary air is either heated or cooled in a 2-pipe or 4-pipe heat exchanger. The supply air, a mixture of primary and secondary air, is uniformly diffused to four sides into the room via preset, divergent ceiling jets covering all four room directions. Room air humidity is controlled through the centrally dehumidified primary air avoiding involuntary dehumidification inside the active chilled beam. The 2-pipe system may be used for either cooling only or change-over operation with cooling/reheating. The 4-pipe system with independent water circuits automatically switches from cooling to heating and vice versa. The design provides complete separation from the ceiling cavity and suppresses sound transmission from adjacent rooms (telephony sound insulation). Advantages Low primary air pressures between 50 and 150 Pa - Low-noise operation; sound pressure may be selected to remain below 35 db(a) - Very low SFP value for secondary air transport (< 0.04 kw/(m³/s)) possible - High secondary (water-side) output with low primary pressure - Excellent air flow balance of the units within a single duct run Flexible nozzle design - Six calibrated, well-matched nozzle combinations - Non combustible metal nozzles - Exchangeable nozzle strip, optional Low installation height (200 mm) - Installation possible in low height suspended ceilings - Facilitates the crossing of utility lines Efficient injector and heat exchanger - High specific secondary output even with low primary air flow rate (in certain areas > 1W/K/(m³/h)) - High heating capacity even with low warm water supply temperatures (e.g. 30 _C) - Lower overtemperature in the heating mode, thus better ventilating efficiency - High cooling capacity with high chilled water supply temperatures (e.g. 16 _C) - Low water flow rates designed for a temperature difference of 3 K Flexible connection of services - Primary air connection with NW 125 on the longitudinal side (standard) - Air connection left or right, as required - Eccentric air connection, if desired, not conflicting with ceiling suspension parts - Water connections outside the unit on top in order to connect from the left or right side Designed for easy maintenance - Easy removal of secondary air grille, secured by metal wires - Easy access for cleaning of heat exchanger and nozzles - No protective air filter required for the heat exchanger. Virtually draught-free indoor air flow - Optimized air distribution with steady, preset divergent, inductive ceiling jet Attractive appearance - Visible surfaces powder coated e.g. sim. to RAL Secondary air grille in the form of a perforated sheet grille (free area > 63%) Easy commissioning - Measuring point to determine the air flow rate (standard) E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 16 of 25
17 Active chilled beams type HDF-600/2A/2 and -600/2A/4, ceiling installation Design - 4-pipe-system for cooling and heating - 2-pipe-system for cooling or heating - Grid sizes 600 mm and 625 mm - Balancing damper KLI Materials and Finish Primary air duct of galvanized sheet steel, nozzle duct and induction nozzles of black coated sheet steel, 1 mm thick; secondary air grille of galvanized sheet steel, powder coated similar to RAL. Accessories - Thermal control valves - Flexible water connections with 12 mm quick coupling Installation in different ceiling systems 593 / / 623 / 1198 / / 1170 Dimensions, 2-way diffusion, 4-pipe system Isometric views Front view Lateral view, left side DN Shownwithsocketontheleft Top view Beispiel Bandmontage L Ø12 Size L A* sockets at high air volumes * only valig with 1 socket A* 2xL E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 17 of 25
18 Active chilled beam type HDF-600/2A/2, ceiling installation Technical data size 600 x 1200, 2-way diffusion, 2-pipe system p Q P / t / t w ok / p w 170 / 3 Technical data size 600 x 1800, 2-way diffusion, 2-pipe system p Q P / t / t w ok / p w 170 / 4.5 Technical data size 600 x 2400, 2-way diffusion, 2-pipe system p Q P / t / t w ok / p w 170 / 6 The chart shows selection examples. Selection software is available for other flow rates, primary pressures, temperatures and water flow rates. Measuring parameters see page 21. Legend see page 21. E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 18 of 25
19 Active chilled beam type HDF-600/2A/4, ceiling installation Technical data size 600 x 1200, 2-way diffusion, 4-pipe system, line assembly p Q P / t / t w ok / p w Q h / t / Q h 2) Technical data size 600 x 1800, 2-way diffusion, 4-pipe system, line assembly p Q P / t / t w ok / p w Q h / t Q h 2) / Technical data size 600 x 2400, 2-way diffusion, 4-pipe system, line assembly p Q P / t / t w ok / p w Q h / t Q h 2) / w oh / p w 110 / 7 w oh / p w 110 / 10 w oh / p w 110 / 13 The chart shows selection examples. Selection software is available for other flow rates, primary pressures, temperatures and water flow rates. Measuring parameters see page 21. Legend see page 21. E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 19 of 25
20 Active chilled beam type HDF-600/4A/2 and -600/4A/4, ceiling installation Dimensions, 4-way diffusion, 2-pipe system and 4-pipe system View from below Lateral view, left side, 2-pipe system 319 Ø ±1 74 Ø ±1 Lateral view, left side, 4-pipe system ca. 60 Front view A 1178 ± Ø12 Ø ± Top view 1148 ± Detail A 33 Detail B 11 B Ø12 E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 20 of 25
21 Active chilled beam type HDF-600/4A/2 and -600/4A/4, ceiling installation Technical data size 600 x 1200, 4-way diffusion, 2-pipe-system p Q P / t / t w ok / p w [kg/h] / [kpa] Q h / t Q h 2) / Technical data size 600 x 1200, 4-way diffusion, 4-pipe-system p Q P / t / t w ok / p w Q h / t / The chart shows selection examples. Selection software is available for other flow rates, primary pressures, temperatures and water flow rates. Data are based on the unit including a secondary air inlet grille 63 % free area. Correction for other flow rates see page 22. Water supply temperature: 16 _C Air inlet temperature or return air temperature: 26 _C Primary air temperature: 16 C 2) Water supply temperature: 40 _C Air inlet temperature or return air temperature: 22 _C Primary air temperature: 22 C Q h 2) w oh / p w 110 / 3 w oh / p w 110 / 1 Legend - primary air flow rate (± 3 %) p - static pressure at the primary air connection - sound pressure level at 18 m 2 Sabine (± 3 db) - sound power level (± 3 db) Q P - air-side cooling capacity (primary air ± 3 %) - water-side cooling capacity (secondary ± 6 %) t - temperature difference between air inlet and water supply w ok - standard water flow rate (cooling) p w - water-side pressure loss Q h - water-side heating capacity (secondary ± 6%) w oh - standard water flow rate (heating) E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 21 of 25
22 Active chilled beams type HDF-600/4A/2 and -600/4A/4, ceiling installation Cooling/heating capacity with different water flow rates for 2-pipe heat exchanger Cooling/heating cap. in % of nominal cap. Water flow rate [kg/h] Capacity with different water flow rates for 4-pipe heat exchanger Cooling capacity Heating capacity Cooling capacity in % of nominal cap Water flow rate [kg/h] Heating capacity in % of nominal cap Water flow rate [kg/h] Water-side pressure loss for 2-pipe heat exchanger / 4-pipe heat exchanger Water-side pressure loss [kpa] Water-side pressure loss [kpa] 16 Cooling Heating Water flow rate [kg/h] Water flow rate [kg/h] E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 22 of 25
23 Active chilled beams series HDF-600, ceiling installation Selection Induction systems are economical if operated locally using the primary air flow based on DIN EN while covering the cooling loads in the room. An occupancy rate typical for offices of 10 m² floor space/person results in a calculated specific primary air flow rate of 5m³/h/m² for a low-emission building. A non-low-emission building requires an outside air flow rate of 7.5 m³/h/m². The cooling loads of offices provided with good solar protection are usually about 40 to 60 W/m². The speciality of the HDF 600 active chilled beam is the supply air diffusion in all four directions. It requires a minimum distance between two units or between unit and wall, respectively, in order to avoid excessive downward jet deflection. 600 x 600 ceiling grid, 4x3gridlight With 8.6 m²/unit and 7.5 m³/h/m²: 65 m³/h/unitt 735 W 85 W/m² Air flow: Supply air is diffused in all four directions Location in the ceiling grid Positioning of the units in the ceiling grid should harmonize with the position of the overhead lights. Avoid being too close to protruding overhead lights. The following examples provide suggestions for a 600 mm grid ceiling with square, mirrored grid lights installed flush. Examples apply to - 10 m²/person - 26 C room temperature - 16 C water supply temperature - 16 C primary air temperature 600 x 600 ceiling grid, 4x2gridlight With 17.3 m 2 /unit and 5 m³/h/m²: 87 m³/h/unit 845 W 49 W/m² With 17,3 m 2 /unit and 7.5 m³/h/m²: 130 m³/h/unit 1120 W 65 W/m² 600 x 600 ceiling grid, 3x3gridlight With 13 m²/unit and 5 m³/h/m²: 65 m³/h/unit 735 W 56 W/m² With 13 m²/unit and 7.5 m³/h/m²: 98 m³/h/unit 1000 W 77 W/m² E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 23 of 25
24 Active chilled beams series HDF-600, ceiling installation Nomenclature HDF-600 / 4A / 2 / 1200 / 45 / 80 / A / S / 600 / RAL... ( (2) (3) (4) (5) (6) (7) (8) (9) (10) ( Series HDF-600 = HDF-600 (2) Type 2A = 2-way diffusion 4A = 4-way diffusion (3) Heat exchanger 2 = 2-pipe system 4 = 4-pipe system (4) Size 900 = = = 1800 (only as HDF-600/2A, 2-way diffusion) 2400 = 2400 (only as HDF-600/2A, 2-way diffusion) (5) Primary air flow rate 45 = E.g. 45 m³/h (6) Primary air pressure 80 = E.g. 80 Pa (7) Return air spigot A = With return air spigot O = Without return air spigot (8) Secondary air grille S = Expanded metal (only available for HDF-600/2A, 2-way diffusion) L = Perforated sheet steel (9) Ceiling gird (diffuser) 600 = 600 (diffuser length 592 mm) 625 = 625 (diffuser length 617 mm) (10) Surface of diffuser RAL... = Coated similar to RAL, indicate RAL-colour E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 24 of 25
25 Active chilled beams HDF, ceiling installation Control system with CO 2 -Sensor VREactive Valve actuator (Smart Flow Technology) Cold water valve Warm water valve Unit Room Signal for flow rate controller V or Room temperature sensor Cool. signal V Heating signal V optional Signal for CO V Window contact 24 AC Power supply Presence sensor VCO 2 V max (10 V) 1. CO 2 control circuit The set value for the flow rate controller depends on actual CO 2 value V min (2 V) SOLL = nominal value, IST = actual value 0 CO 2, SOLL -CO 2, IST Set value for flow rate controller The highest value of the 2 control circuits is decisive. The highest value of the correcting variable of the 2 circuits (CO 2 or temperature) is chosen. Heating valve V min Cooling valve V max, 2. Temperature control circuit Low cooling load ( % of cooling capacity) cooling valves open, V prim remains at V min 0 T SOLL -T IST increased cooling load ( % of cooling capacity) cooling valves are completely opened, V prim opens to V max 1.Dient zur Identifizierung der letzten Seite E Grenzstraße Stuttgart Germany HDF-eng-TP (06/13) Former editions are invalid Subject to technical modifications page 25 of 25
26
27 Product Overview LTG Air-Water Systems Induction InductionUnits Ceiling installation HFFsuite SilentSuite Sill Installation HFV/ HFVsf System SmartFlow Floor Installation HFB / HFBsf System SmartFlow LHG System Indivent HFG HDF / HDFsf System SmartFlow QHG HDC FanPower Fan Coil Units Ceiling Installation Sill Installation Floor Installation LVC System Indivent VFC VKB VKH QVC SKB VKE KFA cool wave Decentral Decentralised Ventilation Units Ceiling Installation Sill Installation Floor Installation FVS Univent FVM FVD FVPpulse System PulseVentilation Engineering Services LTG Engineering Services Comfort Air Technology
28 Comfort Air Technology Air-Water Systems Air Diffusers Air Distribution Process Air Technology Fans Filtration technology Humidification Technology Engineering Services Air flow tests Thermodynamics Acoustics / Comfort Customised solutions FI NO SE EE RU IE DK LV GB RU LT BY NL DE BE DE PL FR LU CZ SK LI CH LI AT MD HU SI HR RO UA PT ES IT BA ME RS BG AL MK GR TR Grenzstraße Stuttgart Germany Tel.: +49 ( Fax: +49 ( info@ltg-ag.com LTG Incorporated 105 Corporate Drive, Suite E Spartanburg, SC USA Tel..: +1 (864) Fax: +1 (864) info@ltg-inc.net HDF-eng-TP (06/13) E Former editions are invalid Subject to technical modifications
The Innovation Company. LTG Aktiengesellschaft. Technical Brochure. LTG Air Distribution. Highly-tight shut-off damper KLB
Technical Brochure LTG Air Distribution Highly-tight shut-off damper KLB Notes Dimensions stated in this brochure are in mm. Dimensions stated in this brochure are subject to General Tolerances according
More informationTechnical Documentation. LTG Fine Filters. Type CDF / UDF
Technical Documentation LTG Fine Filters Type CDF / UDF LTG Fine Filters Type CDF and Typ UDF Only precise adaptation of the filter parameters to the air volume to be filtered will ensure the optimum of
More informationAIR TECH SYSTEMS. Installation Instructions. LTG Air Diffusers. Linear air diffusers LDB. Installation in ceilings, walls and sills
AIR TECH SYSTEMS Installation Instructions LTG Air Diffusers Linear air diffusers LDB Installation in ceilings, walls and sills LTG Comfort Air Technology Air-Water Systems Content Page Safety instructions
More informationLTG High Performance Tangential Fans
AIR TECH SYSTEMS Technical Documentation Series TW Impeller diameter from 125 to 0 mm Content an advantage for best heating, cooling, drying, blasting... 4 Flow principle... 4 Advantages... 4 Application
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13
More informationTechnical brochure. LTG Fans. Tangential fans Type GA 25 / TA 40. Impeller diameter 25 mm / 40 mm.
Technical brochure LTG Fans Tangential fans Type GA 25 / TA 40 Impeller diameter 25 mm / 40 mm www.ltg.net LTG Process Air Technology LTG Fans LTG Filtration Technology LTG Humidification Technology Content
More informationSlot diffusers, Round duct diffusers. IMP Klima
, Round duct diffusers 04 Round duct diffusers 176 , Round duct diffusers SLOT DIFFUSERS, ROUND DUCT DIFFUSERS SWIRL DIFFUSERS, VARIABLE SWIRL DIFFUSERS CIRCULAR DIFFUSERS, SQUARE DIFFUSERS VENTILATING
More informationHomepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM
Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL
More informationCeiling induction diffuser DISA-300
Ceiling induction diffuser DISA-300 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationSwegon PACIFIC. Integrated climate beam
Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,
More informationLTG Air Distribution. Product Overview
Product Overview LTG Air Distribution High-quality air flow control components with innovative technology. Unsurpassed in control precision and energy efficiency. LTG Aktiengesellschaft 1 LTG Aktiengesellschaft
More informationTotal comfort control
Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data
More informationCornerAir. CornerAir. Active chilled beam
Active chilled beam Description The active chilled beam is a one-way induction type air-conditioning unit that is designed for exposed installation, mounted directly under the ceiling against the corner.
More informationSLOT DIFFUSERS, ROUND DUCT DIFFUSERS
SLOT DIFFUSERS, ROUND DUCT DIFFUSERS Slot diffusers LD-3, LD-4, LD-5 LD-3 LD-4 LD-5 SLOT DIFFUSERS Application: Slot diffusers are designed for air supply in rooms with floor to ceiling heights of 2.5
More informationCeiling induction diffuser DISA-601
Ceiling induction diffuser DISA-601 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Phone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationTechnical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.
Technical Brochure LTG Air Distribution Variable flow rate controllers VRFactive Rectangular, with LTG map control www.ltg.net LTG Comfort Air Air-Water-Systems Air Diffusers Air Distribution Content Page
More informationSwegon PACIFIC. Integrated climate beam QUICK FACTS KEY FIGURES
Swegon PACIFIC Integrated climate beam QUICK FACTS The PACIFIC is a high performance climate beam for installation in false ceilings. With high built-in flexibility, it is designed to meet today s needs
More informationTangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")
Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9") 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: 864-599-6340 Fax: 864-599-6344
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,
More informationSwegon PACIFIC. Integrated climate beam
Swegon Integrated climate beam www.eurovent-certification.com www.certiflash.com climate beam The is a high performance climate beam for installation in false ceilings. With high built-in flexibility,
More informationActive Chilled Beams
T 2.4/3/EN/1 Active Chilled Beams Type DID00B TROX GmbH Telephone +49/2 45/2 02-0 Telefax +49/2 45/202-25 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents Description
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,
More informationCeiling diffuser 4DE
Ceiling diffuser 4DE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationKrantz. Floor displacement outlet Q-B-DN 200. Air distribution systems
Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05. Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets
More informationActive Chilled Beams
T 2.4/2/EN/1 Active Chilled Beams Type DID300B TROX GmbH Telephone +49/2 45/2 02-0 Telefax +49/2 45/202-25 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents
More informationLTG Fine Filters Type CDF, Type UDF
LTG Fine Filters Type CDF, Type UDF Example: Type CDF-8 105 Corporate Drive, Suite E Spartanburg, SC 29303 PO Box 2889, Spartanburg, SC 29304 USA Tel: +1 (864) 599-6340 Fax: +1 (864) 599-6344 E-Mail: info@ltg-inc.net
More informationinduction Unit effective and efficient cooling, heating and ventilation
effective and efficient cooling, heating and ventilation MiniB induction Units With MiniMal energy requirements, high output and low noise. induction Unit www.minib.com 2 about us ABOUT THE COMPANY MINIB
More informationinduction Unit effective and efficient cooling, heating and ventilation
effective and efficient cooling, heating and ventilation MiniB induction Units With MiniMal energy requirements, high output and low noise. induction Unit www.minib.com 2 about us ABOUT THE COMPANY MINIB
More informationAdriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation
Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation ADRIATIC VF Climate beam Adriatic Adriatic is an enclosed climate beam with integrated
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air
More informationBRC
------------------------------------------------------------- Enclosed climate beam for cooling, heating and ventilation CLIMATE BEAM is an enclosed climate beam with integrated circulation air openings
More informationType VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL
Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the
More informationCeiling Slot Diffuser Model DSX
Ceiling Slot Diffuser Model DSX Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationType DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION
More informationVERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X
Date: 08.06.2018 Price: 13121 EUR without VAT, W Vilnius Air handling unit model: VERSO-CF-30-2.6-H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X TECHNICAL SPECIFICATION AHU size 30 Typology NRVU BVU of HRS other
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More informationOptima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:
Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-
More informationceiling swirl diffuser Model DQJA / DQJR
ceiling swirl diffuser Model DQJA / DQJR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationResolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h
Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:
More informationFloor Swirls Models BZD and SZD
July 09 Floor Swirls Floor Swirls Models BZD and SZD Features Model BZD Circular Floor Swirl Model SZD Circular Step Diffuser Grilles Diffusers Louvres Chilled Beams Ruskin Air Management Limited www.ruskinuk.co.uk
More informationCCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation
Halton CCE Adaptable active chilled beam for exposed installation Combined cooling, heating, and supply air unit for exposed installation Ideal solution for applications where good indoor environment,
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationCeiling air diffuser INDULCLIP INDUDRALL KOMBICLIP
Technical information Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP Draught-free air distribution Differences in supply air temperature of up to K 7 sizes from 0 to 800 mm, round or square Many different
More informationTechnical Documentation Flow rate controllers type VRF-W (short)
Technical Documentation Flow rate controllers type VRF-W (short) 70435 Stuttgart, Grenzstraße 7, Germany Tel. +49 711 8201-0, Fax +49 711 8201-720 info@ltg-ag.com www.ltg-ag.com LTG Incorporated 105 Corporate
More informationRedefine your comfort zone. chilled beams. energy solutions
integrated lighting u open ceiling k-12 education wood grains dual-function energy solutions Table of Contents CHILLED BEAM PRODCTS Chilled Beam Products...3 Overview...6 ACTIVE CHILLED BEAMS CBAL-24 /
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationCeiling Slot Diffuser DSC
Ceiling Slot Diffuser DSC Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationProduct Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)
Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic
More informationVentiduct nozzle ducts
Ventiduct nozzle ducts About Lindab Comfort and Design Product overview / symbols Theory Ceiling diffusers Ceiling diffusers - visible Plenum boxes Wall diffusers Nozzles Ventiduct Grilles Displacement
More informationUse. Installation. Key figures. Worth noting. linx industries chilled beams
89 Use Lindab's supply air beam can be used for cooling, heating and ventilation. Installation I-60 is installed into a false ceiling, and can be suspended by hangers or threaded rods. As standard is delivered
More informationMaximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment
Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...
More informationSwirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8
Swirl diffuser DHV Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS
Active climate beam with cooling, heating and ventilation QUICK FACTS The ADRIATIC VF is a climate beam with integrated recirculated air opening in the face plate. Air is discharged into the room along
More informationInduction terminal units
series IHK Series IHK 1 Induction terminal units IHK IHK-F IHK-V CONTENTS age eneral Features 2 Dimensions and Configurations 4 Induction terminal unit IHK-F 5 Induction terminal unit IHK-V 6 Installation
More informationPRODUCT BROCHURE. Adjustable Helical Swirl Diffuser HSC-AD HSC-AD : smartemp.com
PRODUCT BROCHURE Adjustable Helical Swirl Diffuser HSC-AD smartemp.com DESCRIPTION The SMARTEMP Adjustable Helical Swirl Diffuser, type HSC-AD, produces highly inductive swirl discharge of the supply air,
More informationfor suspended installation. Active climate beam with cooling, heating and ventilation
for suspended installation. Active climate beam with cooling, heating and ventilation www.euroventcertification.com www.certiflash.com ADRIATIC VF b ADRIATIC VF Climate beam The ADRIATIC VF is a climate
More informationIndustrial Air Diffusers Type LTB/ LTC
LTG Aktiengesellschaft Industrial Air Diffusers Type LTB/ LTC LTG Aktiengesellschaft D - 70435 Stuttgart, Grenzstraße 7 +49 (0711) 82 01-180 Fax +49 (0711) 82 01-720 Internet: http://www.ltg-ag.de E-Mail:
More informationSlot diffusers for ceiling installation
X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger
More informationCeiling diffuser 4DF
Ceiling diffuser 4DF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction...
More informationChiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial
Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single
More informationCommon Safety Indicators (CSIs) as reported by Member States Extracted on 18 October 2013 from ERAIL database (
Table 1 Fatalities by category of persons Victim types Year AT BE BG CT CZ DE DK EE EL ES FI FR HR HU IE IT LT LU LV NL NO PL PT RO SE SI SK UK EU Passengers 2006 0 4 1 4 18 0 3 9 1 12 4 0 5 0 0 1 1 9
More informationDisplacement flow diffusers. L e
Displacement flow diffusers L-08-1-04e Contents Application Safety instructions Contents Application Safety instructions 2 Construction Perforation Principle of operation Example of quick selection 3 Type
More informationRound duct diffuser DBB-RR
Round duct diffuser DBB-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationFan coil unit NBS 100/150
Fan coil unit /150 Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...3
More informationC O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S PERFORATED FACE DIFFUSERS P SERIES P SERIES PERFORATED FACE DIFFUSERS P SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application:
More informationProduct Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm
Product Data 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams 11 to 190 cfm 36CBAC Chilled beam units offer: An increase in total airflow Sensible cooling and heating options Induction
More informationPELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS
Square ceiling air diffuser for supply air and extract air QUICK FACTS Flexible distribution pattern, yet the acoustic data remains the same One K-factor regardless of distribution pattern Designed for
More informationceiling swirl diffuser DQJ
ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...
More informationWGA Long throw nozzle grille
Technical documentation WGA Long throw nozzle grille Contents Function and use... 2 Models... 2 Processing... 3 Accessories... 3 Models and dimensions... 4 Quick selection... 12 Installation situation...
More informationKrantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems
Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems DS 10 E 01.018 Preliminary remarks Where workplaces or production facilities have to be kept
More informationEP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2012/42
(19) (12) EUROPEAN PATENT APPLICATION (11) EP 2 512 002 A2 (43) Date of publication: 17.10.2012 Bulletin 2012/42 (51) Int Cl.: H02J 7/00 (2006.01) H02J 7/35 (2006.01) (21) Application number: 11250613.4
More informationFALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS
Circular ceiling air diffuser for supply air QUICK FACTS Manages large supply airflows Horizontal or vertical distribution pattern Provision for motorised adjustment of the distribution pattern Suitable
More informationCHILLED BEAM IQ STAR WEGA II
CHILLED BEAM IQ STAR WEGA II TECHNICAL CATALOGUE 2 IQ Star WEGA II Chilled beam - Technical catalogue CHILLED BEAM IQ STAR WEGA II The WEGA II chilled beam is an active chilled beam system for ventilation,
More informationEP A1 (19) (11) EP A1 (12) EUROPEAN PATENT APPLICATION. (43) Date of publication: Bulletin 2006/42
(19) Europäisches Patentamt European Patent Office Office européen des brevets (12) EUROPEAN PATENT APPLICATION (11) EP 1 712 388 A1 (43) Date of publication: 18.10.2006 Bulletin 2006/42 (51) Int Cl.:
More informationMULTIDIRECTIONAL DIFFUSERS WITH EXTRACTABLE CONES
MULTIDIRECTIONAL DIFFUSERS WITH ETRACTABLE CONES OVERVIEW AND TECHNICAL DATA 4 Multidirectional 4-ways-diffusers in aluminium - dimensions from mm. 150 x 150 to mm. 600 x 600. MODEL A B D mm mm mm 150
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationACTIVENT System. Specifications. Product code example ACTA
Activent is a ventilation system for supplying and distributing air. The system has been proven to function effectively in both small and large areas and is used in all types of premises ranging from offices
More informationCatalog Swirl diffuser DAL 359
Catalog 1.1.1 DAL 359 Restaurant, Lingen, Germany DAL 359 Model Description, area of application and product benefits............ DAL 359 1 Configuration...................................................
More informationSwirl Diffuser Model DQF
Swirl Diffuser Model DQF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationDisc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1
X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades
More informationseries Linear grilles
series 30 Linear grilles www.koolair.com Series 30 1 CONTENTS Linear grilles 2 Linear floor grilles 3 Quick selection table 4 Example of selection 5 General dimensions 7 Accessories and mounting 10 General
More informationPuri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element
Cleanroom systems Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationTEPZZ 5 59 A T EP A2 (19) (11) EP A2 (12) EUROPEAN PATENT APPLICATION
(19) TEPZZ 5 59 A T (11) EP 2 535 922 A2 (12) EUROPEAN PATENT APPLICATION (43) Date of publication: 19.12.2012 Bulletin 2012/51 (21) Application number: 12172230.0 (51) Int Cl.: H01J 61/26 (2006.01) H01J
More informationRegulation and shut-off damper SPB and SPC
SPB / SP -type multi leaf damper is a robust and reliable regulation and shut-off device to be used for different purposes in air handling systems. SPB SP.01.13 Area of application Multi leaf dampers are
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation
More informationRound duct grille Model KG-RR
Round duct grille Model KG-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...
More informationHalton Rex 600 RE6 - Adaptable active chilled beam
Halton Rex 600 RE6 - Adaptable active chilled beam Halton Rex 600 chilled beam is: Combined cooling, heating, and supply air unit for flush installation within a suspended ceiling. Well suited for spaces
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More informationHRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR
4 Lmf Clima 6 FERRARO GROUP HRS Very high efficiency heat recovery units WITH HIGH EFFICIENCY HEAT RECOUPERATOR from 3 to 4. m³/h Air-handling unit designed and manufactured for nonresidential applications,
More informationSupply air unit DYBA. Specifications. Connbox. Quick Selection DYBA, without slot, 1:3 plenum box ATTC (50 Pa)
DYBA is a quiet, ceiling-mounted supply air unit that consists of a nozzle diffuser, DYBH, and an insulated plenum box, ATTC. The nozzles of the diffuser produce a swirl pattern, which provides a highly
More information