1 Commercial Refrigeration Condensed Product Catalog Technical Bulletin: CRCC_004_ Products that provide lasting solutions.

2

3 Commercial Condensed Product Catalog Table of Contents Series Unit Coolers 2 G/G Series Unit Coolers 3 KR Series Unit Coolers 5 MK/MV Series Unit Coolers 7 MS Series Unit Coolers 10 SM/SV Series Unit Coolers 13 Microchannel AirCooled Condenser 17 evitor II Series AirCooled Condenser 19 evitor II Series and Microchannel AirCooled Condensers Control Panel Nomenclature 30 CS/CD/CP Condensing Units 31 1

4 Series Unit Coolers Dual Dischargeow ite Series Standard Features n Compact design with flush ceiling mount takes up less space, allows more products to be stored on the shelf. n EC motors standard for 115/1 and 230/1. n Twoway air discharge provides smooth air movement, keeps product fresh longer with less drying and weight loss. n igh efficiency aluminum fins with staggered copper tubes for optimum heat transfer and proper system balance. n All controls are factory wired to a terminal strip for easy installation. UNIT TYPE: ow eight NUMBER OF FANS FIN SPACING: 4, 6 FPI TYPE OF DEFROST: A Air B Brine w/air Defrost E Electric w/electric Pan J Brine w/electric Defrost Coil and Pan R eat Reclaim 2 6 E 86 B A A BTU/ IN UNDREDS (00) MOTOR TYPE: B PSC Motors (Optional) E EC Motors (Standard) Use your QR reader to reference current document version on MOTOR VOTAGE: A /1/60 B 115/1/60 EATER VOTAGE: A /1/60 AIR DEFROST MEDIUM TEMPERATURE STANDARD VEOCITY CAP. AIR CARGE EC MOTOR STANDARD (BTU) FO BS OF 115/1/60 6 Fins per Inch 16A47 26A94 36A140 46A187 4 Fins per Inch 14A36 24A73 34A F TD R404A AMPS ATTS NOTE: MCA = 5 x AMP of One Motor + AMP of All Remaining Motors. PSC MOTOR OPTIONA 115/1/60 AMPS ATTS GT. (BS) EECTRIC DEFROST O TEMPERATURE 6 Fins per Inch 16E43 26E86 36E129 46E171 4 Fins per Inch 14E33 24E67 34E100 44E132 CAP. 10 F TD 20 F SST F SST AIR FO CARGE BS OF R404A EC MOTOR STANDARD PSC MOTOR OPTIONA EATERS /1/ /1/60 230/1 AMPS ATTS AMPS ATTS AMPS ATTS STANDARD VEOCITY GT. (BS)

5 G/G Series Unit Coolers Standard Features UNIT TYPE: G & G Gentle Air NUMBER OF FANS FIN SPACING: 4, 6 FPI TYPE OF DEFROST: A Air B Brine w/air Defrost C Brine w/electrical Defrost Coil D Electric w/no Pan eat F 3 Pipe ot Gas w/no Pan eat BTU/ IN UNDREDS (00) MOTOR TYPE: B PSC Motors (Optional) E EC Motors (Standard) MOTOR VOTAGE: A /1/60 B 115/1/60 G 2 6 A B A K 3 Pipe ot Gas w/electric Drain Pan M 2 Pipe Kool Gas w/no Pan eat P 2 Pipe Kool Gas w/electric Drain Pan R eat Reclaim n ow velocity. n EC motors standard for 115/1 and 230/1. n ow and high silhouette models are installed level and tight to ceiling; mounting holes and optional TEV are internal resulting in a clean appearance. n Serviceable, textured aluminum housing features hinged orifice drain pan, pitched to drain condensate at end of unit. n Plastic fan guard. EATER VOTAGE: A /1/60 B 115/1/60 Drain Pan Only &P Defrost K /3/60 6 Fins per Inch G16A60 G26A130 G36A198 G46A270 G56A340 G66A410 4 Fins per Inch G14A50 G24A100 G34A150 G44A200 G54A250 G64A300 CAPACITY 10 F TD AIR DEFROST O VEOCITY MEDIUM TEMPERATURE GENTE AIR 18" IG SIOUETTE MEDIUM TEMPERATURE EC MOTORS STANDARD PSC MOTOR OPTIONA CARGE BS OF 115/1/60 230/1/60 115/1/60 230/1/60 R404A AMPS ATTS AMPS ATTS AMPS ATTS AMPS ATTS AIR FO Use your QR reader to reference current document version on GT. (BS) Fins per Inch G16A45 G26A G36A135 G46A180 G56A225 G66A268 4 Fins per Inch G14A35 G24A70 G34A105 G44A140 G54A175 G64A210 CAPACITY 10 F TD GENTE AIR 12" O SIOUETTE MEDIUM TEMPERATURE AIR EC MOTORS STANDARD PSC MOTOR OPTIONA CARGE FO BS OF 115/1/60 230/1/60 115/1/60 230/1/60 R404A AMPS ATTS AMPS ATTS AMPS ATTS AMPS ATTS GT. (BS)

6 G/G Series Unit Coolers EECTRIC DEFROST O VEOCITY MEDIUM TEMPERATURE GENTE AIR 18" IG SIOUETTE (Operating Range +20 F and Above) 6 Fins per Inch G16D60 G26D130 G36D198 G46D270 G56D340 G66D410 4 Fins per Inch G14D50 G24D100 G34D150 G44D200 G54D250 G64D300 CAPACITY 10 F TD AIR FO CARGE BS OF R404A EC MOTORS STANDARD 115/1/60 230/1/60 A M PS ATTS A M PS ATTS PSC MOTOR OPTIONA 115/1/60 230/1/60 A M PS ATTS A M PS ATTS EATERS 230/1 A M PS ATTS SIP GT. (BS) GENTE AIR 12" O SIOUETTE (Operating Range +20 F and Above) 6 Fins per Inch G16D45 G26D G36D135 G46D180 G56D225 G66D268 4 Fins per Inch G14D35 G24D70 G34D105 G44D140 G54D175 G64D210 CAPACITY 10 F TD AIR FO CARGE BS OF R404A EC MOTORS STANDARD 115/1/60 230/1/60 A M PS ATTS A M PS ATTS PSC MOTOR OPTIONA 115/1/60 230/1/60 A M PS ATTS A M PS ATTS EATERS 230/1 A M PS ATTS SIP GT. (BS)

7 KR Series Unit Coolers Standard Features UNIT TYPE: KR Compact Series NUMBER OF FANS FIN SPACING: 4, 6 FPI BTU/ IN UNDREDS (00) MOTOR TYPE: A Shaded Pole Motors (460V only) B PSC Motors (Optional) E EC Motors (Standard) MOTOR VOTAGE: A /1/60 B 115/1/60 460/1/60 KR 2 6 E 075 B A A TYPE OF DEFROST: A Air 3 Pipe ot Gas w/electric Drain Pan B Brine J Brine w/electric Defrost (Coil & Pan) E Electric w/electric Pan K 2 Pipe Kool Gas w/kool Gas Drain Pan G 3 Pipe ot Gas w/ot Gas Drain Pan P 2 Pipe Kool Gas w/electric Drain Pan EATER VOTAGE: A /1/60 B 115/1/60 Drain Pan Only &P 460/1/60 K /3/60* * Defrost heater only n Swept ing Fan Blade Design providing low noise operation. n Plastic fan guard. n Front access to refrigeration components for serviceability. n Electrical panel located behind front access hinged aluminum cover. n New rifled tubing and enhanced fin design improve heat transfer. n Factory wired fan and defrost controls with convenient terminal strips. n EC motors standard for 115/1 and 230/1. n Superheat gauge fitting. n Flat top for flush mounting. n Plug in motor leads. n Available as /1/60 and 115/1/60. Use your QR reader to reference current document version on AIR DEFROST MEDIUM TEMPERATURE KR16A040 KR16A054 KR16A060 KR26A072 KR26A089 KR26A105 KR26A115 KR26A KR36A134 KR36A159 KR36A170 KR46A216 KR56A242 KR66A310 KR66A340 KR14A058 KR24A096 KR24A117 KR34A143 KR34A173 KR44A191 KR44A232 KR54A2 KR64A348 CAP. 10 F TD +25 F SST AIR FO EC MOTOR STANDARD 115/1/60 AMPS ATTS PSC MOTOR OPTIONA 115/1/60 AMPS ATTS GT. (BS)

8 KR Series Unit Coolers EECTRIC DEFROST O TEMPERATURE KR14E037 KR16E035 KR16E041 KR16E045 KR24E065 KR24E074 KR26E067 KR26E075 KR26E0 KR34E111 KR36E126 KR36E135 KR44E148 KR46E160 KR46E180 KR54E185 KR56E KR64E213 KR64E220 KR66E KR66E270 CAPACITY 10 F TD 20 F SST +20 F SST AIR FO EC MOTOR STANDARD PSC MOTOR OPTIONA EATERS /1/ /1/60 230/1 AMPS ATTS AMPS ATTS AMPS ATTS GT. (BS) OT GAS DEFROST O TEMPERATURE CAPACITY (BTU) AIR EC MOTOR 10 F TD FO /1/60 20 F SST +20 F SST AMPS ATTS KR14( ) KR16( ) KR16( ) KR16( ) KR24( ) KR24( ) KR26( ) KR26( ) KR26( ) KR34( ) KR36( ) KR36( ) KR44( ) KR46( ) KR46( ) KR54( ) KR56( ) KR64( ) KR64( ) KR66( ) KR66( ) NOTE: Available Types of Defrost: (P) KGE 2 Pipe Kool Gas with Electric Pan (K) KGG 2 Pipe Kool Gas with Kool Gas Pan () GE 3 Pipe ot Gas with Electric Pan (G) GG 3 Pipe ot Gas with ot Gas Pan PSC MOTOR OPTIONA /1/60 AMPS ATTS GT. (BS)

9 MK/MV Series Unit Coolers Standard Features MK 2 6 E 152 B A A UNIT TYPE: MK & MV Medium Profile NUMBER OF FANS FIN SPACING: 4, 6, 8 FPI TYPE OF DEFROST: A Air 3 Pipe ot Gas w/electric Drain Pan B Brine K 2 Pipe Kool Gas w/kool Gas Drain Pan D Electric w/no Pan eater P 2 Pipe Kool Gas w/electric Drain Pan E Electric w/electric Pan R eat Reclaim G 3 Pipe ot Gas w/ot Gas Drain Pan n ire fan guard(s). n Fin spacing 4, 6, and 8 FPI (8 FPI Air Defrost only). n Compartmented fan sections. n EC motors standard for 115/1 and 230/1. n ifetime lubricated totally enclosed PSC motor(s) are optional. n Superheat gauge fitting. n Available as /1/60, 115/1/60, 460/1/60. n Motors are Single Phase, can be wired for 3 Phase on 2 fan or more models. BTU/ IN UNDREDS (00) MOTOR TYPE: B PSC Motors (Optional) E EC Motors (Standard) MOTOR VOTAGE: A /1/60 K /3/60 B 115/1/60 M 460/3/60 460/1/60 (2 4 Fans Only) EATER VOTAGE: A /1/60 K /3/60 M 460/3/60 (2 4 Fans Only) 460/1/60 Use your QR reader to reference current document version on AIR DEFROST MEDIUM PROFIE MEDIUM TEMPERATURE MK14A68 MK14A94 MK14A121 MK16A86 MK16A118 MK16A145 MK18A98 MK18A133 MK18A160 MK24A188 MK24A242 MK26A172 MK26A236 MK26A2 MK28A196 MK28A266 MK28A320 MK34A363 MK36A354 MK36A435 MK38A393 MK38A480 MK44A484 MK46A580 MK48A640 CAP. 10 F TD +20 F SST AIR FO EC MOTOR STANDARD 115/1/60 AMPS ATTS PSC MOTOR OPTIONA 115/1/60 AMPS ATTS GT. (BS)

10 MK/MV Series Unit Coolers 8 MK14E60 MK14E82 MK14E105 MK16E76 MK16E103 MK16E127 MK24E120 MK24E164 MK24E210 MK26E152 MK26E206 MK26E254 MK34E246 MK34E315 MK36E309 MK36E381 MK44E420 MK46E508 MV14E73 MV14E100 MV14E128 MV16E93 MV16E126 MV16E155 MV24E146 MV24E200 MV24E256 MV26E186 MV26E252 MV26E310 MV34E300 MV34E384 MV36E378 MV36E465 MV44E512 MV46E620 GT. (BS) F SST F SST N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A AIR FO CAPACITY 10 F TD ow Temperature Room Temperature Below +30 F Extra igh Velocity AMPS ATTS AMPS ATTS PSC MOTOR OPTIONA EC MOTOR STANDARD /1/ /1/60 AMPS ATTS EATERS 230/1 EECTRIC DEFROST MEDIUM PROFIE O / MEDIUM TEMPERATURE

11 MK/MV Series Unit Coolers OT GAS DEFROST O / MEDIUM TEMPERATURE CAPACITY 10 F TD 20 F SST +20 F SST AIR FO EC MOTOR STANDARD /1/60 AMPS ATTS PSC MOTOR OPTIONA /1/60 AMPS ATTS GT. (BS) MK14( )60 MK14( )82 MK14( )105 MK16( )76 MK16( )103 MK16( )127 MK24( )120 MK24( )164 MK24( )210 MK26( )152 MK26( )206 MK26( )254 MK34( )246 MK34( )315 MK36( )309 MK36( )381 MK44( )420 MK46( ) (P) KGE 2 Pipe Kool Gas with Electric Pan () GE 3 Pipe ot Gas with Electric Pan *Available Types of Defrost: (K) KGG 2 Pipe Kool Gas with Kool Gas Pan (G) GG 3 Pipe ot Gas with ot Gas Pan 9

12 MS Series Unit Coolers Standard Features n Medium profile, galvanized steel cabinet. n 14 fans 20 diameter. n 15, ,200 TD. n 4, 6, or 7 fins per inch air defrost. n 4, 5, or 6 fins per inch electric or hot gas defrost. n 1/2 h.p. ballbearing motors. n 115V, 230/1, 230/3, 460/3, and 575/3. n Inverter Duty Suitable motor. Use your QR reader to reference current document version on UNIT TYPE: MS Super Cooler NUMBER OF FANS FIN SPACING: 4, 5, 6, 7 FPI MS 2 6 E 3 C K K TYPE OF DEFROST: A Air 3 Pipe ot Gas w/electric Drain Pan B Brine K 2 Pipe Kool Gas w/kool Gas Drain Pan D Electric w/no Pan eat P 2 Pipe Kool Gas w/electric Drain Pan E Electric w/electric Pan R eat Reclaim G 3 Pipe ot Gas w/ot Gas Drain Pan BTU/ IN UNDREDS (00) MOTOR TYPE: B PSC Motors (Optional) C 3 Phase Motors, Inverter Duty Suitable Motor (Standard) MOTOR VOTAGE: A /1/60 M 460/3/60 B 115/1/60 P 575/3/60 K /3/60 EATER VOTAGE: A /1/60 K /3/60 M 460/3/60 P 575/3/60 10

13 MS Series Unit Coolers 11 MS14A150 MS14A1 MS14A225 MS14A249 MS16A184 MS16A229 MS16A260 MS16A281 MS17A199 MS17A246 MS17A275 MS17A295 MS24A300 MS24A381 MS24A450 MS24A498 MS26A367 MS26A459 MS26A520 MS26A562 MS27A398 MS27A492 MS27A550 MS27A591 MS34A524 MS34A623 MS34A708 MS36A626 MS36A712 MS36A806 MS37A663 MS37A755 MS37A849 MS44A699 MS44A830 MS44A944 MS46A835 MS46A949 MS46A1075 MS47A885 MS47A1007 MS47A1132 GT. (BS) CAP. 10 F TD +20 F SST AIR FO /3 575/3 460/3 115/ / FAN MOTOR AMPS AIR DEFROST MEDIUM PROFIE MEDIUM TEMPERATURE

14 MS Series Unit Coolers EECTRIC DEFROST MED PROFIE O TEMP CAP. (BTU) EECTRIC DEFROST with EECTRICA 10 F TD FAN MOTOR AMPS DRAIN PAN (E) FO 230V/3 MS14E162 MS14E212 MS15E178 MS15E223 MS16E195 MS16E239 MS24E323 MS24E424 MS25E356 MS25E444 MS26E3 MS26E478 MS34E445 MS34E602 MS35E502 MS35E643 MS36E532 MS36E685 MS44E594 MS44E803 MS45E669 MS45E858 MS46E710 MS46E F SST F SST /3 460/3 575/3 k * * 17.4* 2* AMPS * * 43.8* 5* *Two circuits with 6k and Amps each. Amount shown in chart is total k and Amps. GT. (BS) OT GAS DEFROST MED PROFIE O TEMP MS14( )162 MS14( )212 MS15( )178 MS15( )223 MS16( )195 MS16( )239 MS24( )323 MS24( )424 MS25( )356 MS25( )444 MS26( )3 MS26( )478 MS34( )445 MS34( )602 MS35( )502 MS35( )643 MS36( )532 MS36( )685 MS44( )594 MS44( )803 MS45( )669 MS45( )858 MS46( )710 MS46( )914 CAP. 10 F TD 20 F SST F SST AIR FO 4,120 3,920 4,060 3,8 4,040 3,850 8, 7,840 8,120 7,780 8,080 7,700 12,135 11,325 12,015 11,205 11,895 10,995 16,180 15,100 16,020 14,940 15,860 14, / FAN MOTOR AMPS / /3 460/3 575/3 GT. (BS)

15 SM/SV Series Unit Coolers Standard Features n inged drain pan. n Door access to vestibules. n Galvanized housing. n Dual voltage ball bearing motors. n 1 hp 850 rpm motor SM model only. n 11/2 hp 1140 rpm motor SV model only. n 230/3/60, 460/3/60, 575/3/60, and 380/3/50. n Inverter Duty Suitable motor. Use your QR reader to reference current document version on UNIT TYPE: SM Space Master SV igh Velocity NUMBER OF FANS FIN SPACING: 4, 5, 6, 7 FPI SM 2 5 E 842 C K K TYPE OF DEFROST: A Air 3 Pipe ot Gas w/electric Drain Pan B Brine K 2 Pipe Kool Gas w/kool Gas Drain Pan D Electric w/no Pan eat P 2 Pipe Kool Gas w/electric Drain Pan E Electric w/electric Pan R eat Reclaim G 3 Pipe ot Gas w/ot Gas Drain Pan BTU/ IN UNDREDS (00) MOTOR TYPE: C 3 Phase Motors, Inverter Duty Suitable Motor (Standard) MOTOR VOTAGE: K /3/60 P 575/3/60 M 460/3/60 U 380/3/50 EATER VOTAGE: K /3/60 M 460/3/60 P 575/3/60 U 380/3/50 13

16 SM/SV Series Unit Coolers SM14A314 SM16A378 SM17A410 SM14A403 SM16A463 SM17A503 SM14A469 SM16A538 SM17A585 SM14A526 SM16A604 SM17A657 SM24A619 SM26A746 SM27A811 SM24A797 SM26A915 SM27A995 SM24A882 SM26A1063 SM27A1155 SM24A1038 SM26A1 SM27A1296 SM34A1123 SM36A1289 SM37A1402 SM34A1243 SM36A1498 SM37A1628 SM34A1463 SM36A1678 SM37A1824 SM44A1532 SM46A1846 SM47A0 SM44A1829 SM46A2204 SM47A2281 SM44A2015 SM46A2428 SM47A2581 CAP. 10 F TD AIR DEFROST IG PROFIE MEDIUM TEMPERATURE AIR FO FAN MOTOR AMPS /3 460/3 575/ GT. (BS) Capacity Ratings are based on sensible heat removal with a TEV fed, medium frosted coil when: Fan motor heat is not included in ratings add 4000 BTU per fan to room load for SM units, or 6600 BTU per fan to room load for SV units. Derate 10% for 50 ertz (8 multiplier) or increase TD to compensate for lower fan RPM. 14

17 SM/SV Series Unit Coolers EECTRIC DEFROST IG PROFIE MEDIUM TEMPERATURE CAPACITY 10 F TD AIR FO FAN MOTOR AMPS SM SM14E384 SM15E426 SM16E440 SM14E501 SM15E556 SM16E574 SM24E759 SM25E842 SM26E869 SM24E989 SM25E1097 SM26E1132 SM34E1070 SM35E1186 SM36E1225 SM34E1393 SM35E1544 SM36E1594 SM44E1465 SM45E1523 SM46E1754 SM44E1769 SM45E F SST F SST /3 460/3 575/3 CAPACITY 10 F TD AIR FO FAN MOTOR AMPS 20 F F SST /3 460/3 575/3 ow Temperature Only Room Temperature Below +30 F SV14E SV15E SV16E SV14E SV15E SV24E SV25E SV26E SV24E SV25E SV26E SV34E SV35E SV36E SV34E SV35E SV36E SV44E SV45E SV46E SV44E SV45E SV46E Capacity Ratings are based on sensible heat removal with a TEV fed, medium frosted coil when: Fan motor heat is not included in ratings add 4000 BTU per fan to room load for SM units, or 6600 BTU per fan to room load for SV units. Derate 10% for 50 ertz (8 multiplier) or increase TD to compensate for lower fan RPM. MCA (Minumin Circuit Ampacity) = 5 x FA of One Motor + FA of All Remaining Motors. MOP (Maximum Overcurrent Protection) = 2.25 x FA of One Motor + FA of All Remaining Motors Insulated drain pan standard on E models. Four fan SM/SV for low temperature requires two TEVs. GT. (BS) GT. (BS)

18 SM/SV Series Unit Coolers EECTRIC DEFROST EATERS COI AND PAN E 1 FAN 384, 426, 440, 501, 556, , 468, 550, 611, FAN 759, 842, 869, 989, 1097, , 926, 1005, 1088, 1206, FAN 1070, 1186, 1225, 1177, 1304, , 1544, 1594, 1530, 1698, FAN 1465, 1523, 1754, 1699, 1883, , 1985, 2307, 2052, 2274, 2472 CIRCUIT 1 AMPS K CIRCUIT 2 CIRCUIT 3 AMPS K AMPS K OT GAS DEFROST IG PROFIE O TEMPERATURE SM14( )384 SM15( )426 SM16( ) 440 SM14( )501 SM15( )556 SM16( )574 SM24( )759 SM25( )842 SM26( )869 SM24( )989 SM25( )1097 SM26( )1132 SM34( )1070 SM35( )1186 SM36( )1225 SM34( )1393 SM35( )1544 SM36( )1594 SM44( )1465 SM45( )1523 SM46( )1754 SM44( )1769 SM45( )1985 SM46( )2307 CAP. 10 F TD 20 F SST F SST AIR FO FAN MOTOR AMPS /3 460/3 575/ GT. (BS) NOTE: Available Types of Defrost: (P) KGE 2 Pipe Kool Gas with Electric Pan (K) KGG 2 Pipe Kool Gas with Kool Gas Pan () GE 3 Pipe ot Gas with Electric Pan (G) GG 3 Pipe ot Gas with ot Gas Pan NOTE: 4 Fans SM/SV for low temp requires 2 TEVs. 16

19 Microchannel AirCooled Condenser Standard Features Use your QR reader to reference current document version on krack.com. Standard Motors Shown without included 22 legs. Electronically Commutated Axitop Motors The Microchannel AirCooled Condenser is an exciting product that represents the commitment to GREEN solutions providing added customer value. The Microchannel Condensers offer dramatic valueadded features not available on traditional condensers. n Reduce refrigerant charge expense by as much as 75% and Be Green! igh efficiency coil with reduced internal volume. Optional coil reduction controls eliminate winter flooding charge. n Save on building construction costs. Reduced weight by as much as 40% over conventional condensers. ow profile and smaller footprint reduces screening requirements. Integral structural framing reduces curbing costs. n Ideal match for Protocol and Excel provides Green Solution. In combination with Protocol and Modular Excel coils, provides the lowest refrigerant charge DX system available. n Patented modular design. n Available in 2, 4, 6, 8, 10, 12, and 14 fan configurations. n Reduced life cycle costs to the customer. Easily replaceable coil sections. Coil sections common between all models means enhanced parts availability. Easily cleanable coil. Optional coil filter screen. n Inverterready motors are standard on A,C, and F except 575/3. n Title 24 complaint. Optional Features UNIT TYPE: MX = Microchannel FAN/MOTOR COMBINATION: A=1 P 850 RPM 30" C=11/2 P 850 RPM 30" E=1/2 P 575 RPM 30" F=11/2 P 1140 RPM 30" = P 1020 RPM EC MX F 06 M MOTOR VOTAGE: K= 208/230/3/60 M= 460/3/60 P= 575/3/60 U= 380/3/50 (Capcity Derate of Around 10%) TOTA NUMBER OF FANS: n Electrofin coated coils. n Fan cycling controls. n Extended legs. n Relay boards. n Mounted receivers. n inter flooding controls. n EC AxiTop Fan motors for 230/3/60 and 460/3/60. n Inverter Duty Suitable fan motor, not available on 575/3/60 models. 17

20 Microchannel AirCooled Condenser MICROCANNE CONDENSER TR IN MB 10 F TD R404A 1/2 P, 575 RPM MXE02 MXE04 MXE06 MXE08 MXE10 MXE12 MXE14 1 P, 850 RPM MXA02 MXA04 MXA06 MXA08 MXA10 MXA12 MXA /2 P, 850 RPM MXC MXC MXC MXC MXC MXC MXC /2 P, 1140 RPM MXF02 MXF04 MXF06 MXF08 MXF10 MXF12 MXF AIR FO FAN MOTOR TOTA FU OAD AMPS /3/60 460/3/60 575/3/ * GT. (BS) MX( )02 MX( )04 MX( )06 MX( )08 MX( )10 MX( )12 MX( )14 REFRIGERANT CARGE SUMMER R404A (BS) INTER R404A (BS) 20 F *NOTE: 1. inter Flooding charge doesn t reflect module isolation valves. 2. eight includes 22 shiploose legs. 3. Units with mounted receivers, unit height is equal to MCA (Minumum Circuit Ampacity) = 5 x FA of One Motor + FA of All Remaining Motors. 5. MOP (Maximum Overcurrent Protection) = 4.0 x FA of One Motor + FA of All Remaining Motors. 18

21 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) Standard Features Use your QR reader to reference current document version on krack.com. n evitor coil support system virtually eliminates leaks at tube sheet. n Corrosion resistant. n Direct drive sweptwing fans. n Quiet operation. n ist price includes motors wired to terminal blocks only. n Fluid Cooler models specific to job requirements (Contact Krack sales for information). n Inverterready motors are standard on A, C, E, and F except 575/3. n Title 24 complaint. Optional Features Standard Motors Electronically Commutated Axitop Motors n Coil coatings. n Extended legs. n Factorymounted receivers. n Electrofin coating. n Factory mounted controls. A V A M UNIT TYPE: = evitor Condenser TUBE DIAMETER: A=3/8 O.D. E=1/2 O.D. FAN DISCARGE DIRECTIONS: =orizontal V= Vertical X = inged Vertical E=inged orizontal FAN/MOTOR COMBINATION: A=1 P 850 RPM 30" B=1/2 P 1140 RPM 24" C = 11/2 P 850 RPM 30" E = 1/2 P 575 RPM 30" F = 11/2 P 1140 RPM 30" FANS IDE: 1, 2 VOTAGE: A = 230/1/60 (24 Fan B Model Only) K = /3/60 M = 460/3/60 P = 575/3/60 U = 380/3/50 (Capacity Derate of Around 10%) FIN SPACING: 08 = 8 FPI 10 = 10 FPI 12 = 12 FPI ROS DEEP: FANS IN INE: = 24" Fan Only (B Motor) 19

22 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVA/EVA Features 1.P. 850 RPM One Fan ide 30" AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA 18 AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA EVA EVA EVA EVA EVA EVA TR in MB 10 F TD R404A AIR FO FAN MOTOR TOTA FU OAD AMPS /3/60 460/3/60 575/3/ GT. (BS) NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of all remaining motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 20

23 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVA/EVA Features 1.P. 850 RPM Two Fans ide 30" AVA AVA AVA AVA AVA AVA AVA 28 AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA AVA EVA EVA EVA EVA EVA EVA TR in MB 10 F TD R404A AIR FO FAN MOTOR TOTA FU OAD AMPS /3/ /3/ /3/ GT. (BS) NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 21

24 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVB Features 1/2.P RPM TR in MB (000) AIR FO FAN MOTOR TOTA FU OAD AMPS One Fan ide 24" AVB AVB 10 F TD R404A /3/60 460/3/ /3/ GT. (BS) AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB 18 AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors.

25 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVB Features TR in MB 10 F TD R404A AIR FO 1/2.P RPM FAN MOTOR TOTA FU OAD AMPS /3/60 460/3/60 575/3/60 Two Fans ide AVB AVB AVB AVB AVB AVB AVB 28 AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB AVB NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. GT. (BS) 23

26 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVC/EVC Features One Fan ide 30" AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC 18 AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC EVC EVC EVC EVC EVC EVC TR in MB 10 F TD R404A AIR FO /3/ NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 11/2.P. 850 RPM FAN MOTOR TOTA FU OAD AMPS 460/3/ /3/ GT. (BS)

27 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVC/EVC Features Two Fans ide 30" AVC AVC AVC AVC AVC AVC AVC 28 AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC AVC EVC EVC EVC EVC EVC EVC TR in MB 10 F TD R404A AIR FO /2.P. 850 RPM FAN MOTOR TOTA FU OAD AMPS /3/ /3/ /3/ GT. (BS) NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 25

28 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVE/EVE Features One Fan ide 30" AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE 18 AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE EVE EVE EVE EVE EVE EVE TR in MB 10 F TD R404A AIR FO /2.P. 575 RPM FAN MOTOR TOTA FU OAD AMPS /3/ /3/ /3/ GT. (BS) NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 26

29 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVE/EVE Features 1/2.P. 575 RPM Two Fans ide 30" AVE AVE AVE AVE AVE AVE AVE 28 AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE AVE EVE EVE EVE EVE EVE EVE TR in MB 10 F TD R404A AIR FO FAN MOTOR TOTA FU OAD AMPS /3/60 460/3/60 575/3/ GT. (BS) NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 27

30 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVF/EVF Features One Fan ide 30" AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF 18 AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF EVF EVF EVF EVF EVF EVF TR in MB 10 F TD R404A AIR FO /2.P RPM /3/ NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. FAN MOTOR TOTA FU OAD AMPS 460/3/ /3/60 GT. (BS)

31 evitor II Series AirCooled Condenser (Available for Fluid Cooler Applications) AVF/EVF Features 11/2.P RPM Two Fans ide 30" AVF AVF AVF AVF AVF AVF AVF 28 AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF AVF EVF EVF EVF EVF EVF EVF TR in MB 10 F TD R404A AIR FO FAN MOTOR TOTA FU OAD AMPS /3/60 460/3/60 575/3/ GT. (BS) NOTE: Minimum Unit Circuit Amps = 5 x FA of One Motor FA of All Remaining Motors. Maximum Unit Overload Protection = 4.0 x FA of One Motor + FA of All Remaining Motors. 29

32 evitor II/Microchannel AirCooled Condensers Control Panel Nomenclature REAY BOARD (Optional) If supplied with condenser specify: Danfoss, Novar, Others CPC PT B N AMBIENT AIR SENSOR FOR SPIT T = Sensor Provided (evitor Only) N = Sensor Not Required REAY BOARD CONTROS: NC = No Controls PT = Pressure Controls TF = Temp. Controls TP = Temperature and Pressure Control PV =Pressure Control w/variable Speed ead Fans TV = Temp. Control w/variable Speed ead Fans VN = No Controls w/variable Speed ead Fans TYPE OF APPICATION: 1= Standard 2= 50% inter Reduction Relay (Split Condenser) (evitor Only) 3= 50/50 Split Dual Panel (For Two Indep. Slabs) (evitor Only) 4= No Control Operation (Terminal Blocks Only) FUSES AND BREAKERS: 1 = Individual Fuses and Contactors per Fan 2=Individual Circuit Breakers and Contactors per Fan 3 = Fuses and Contactors per Pair of Fans 4 = Terminal Blocks Only 5=Circuit Breaker and Contactor per Pair of Fans 6 = Fuses per Motor CONTRO MANUFACTURER: 1 = Johnson Mechanical 3 = Johnson Electronic 4 = No Controls CONTRO VOTAGE: A= 208/230V B= 115V C= No Control Voltage D= 24V E = 208/230V w/o Transformer F = 115V w/o Transformer = 24V w/o Transformer 30

33 CS/CD/CP Condensing Units Standard Features n Replaceable core liquid line filter drier and sight glass. n Encapsulated high pressure cutout. n Electronic oil pressure switch. n Adjustable low pressure control. n 230V control circuit with transformer (where needed). n Adjustable low ambient head pressure control valve. n ow temperature units: Suction accumulator. n Subcooling circuit. n 11/2 P 1140 RPM motors. n Inverter Duty Suitable motor. Use your QR reader to reference current document version on krack.com. Optional Features n Pressure fan cycling. n Sealed suction filter. n 115V control voltage with transformer. n Oil separator system to activate flow of oil (Recommended for room temperatures of 10 F and below). n Suction accumulator (medium/high temperature). n Replaceable core suction filter. n eated and insulated receiver. n Electrical control panel with all necessary controls to run electric defrost evaporators (includes timer, contactors). n Air defrost timer. n Shipped loose fused disconnect. n Mounted nonfused disconnect with interlock. n Cylinder unloaders for compressors. n Alternate fin materials, such as vinyl coated and copper, can be specified for adverse environmental conditions. n P 850 RPM with low noise fan blades. n Condenser access/clean out doors. n Oversized condenser (models preengineered). 31

2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax:

2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax: Expires: 4/1/2017 2017 Price List Changes since the last Price List: Correct rupture disc assembly price Corrected H unit pricing to match condenser and receivers listed. Update Danfoss nomenclature for

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPE-PDI-3 Part # 1081588 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile orator Low & Medium Temperature Electric

More information

High Profile Evaporator

High Profile Evaporator High Profile orator PRODUCT DATA & INSTALLATION Bulletin K30-KHPHG-PDI-3 Part # 1081591 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Low & Medium Hot Gas Defrost

More information

LOW HEIGHT UNIT COOLER

LOW HEIGHT UNIT COOLER Publication No. RU-CTA-0818A Replaces RU-CTA-0712A Ceiling-Temp LOW HEIGHT UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost,00 to 27,00 BTUH Electric Defrost 5,00 to 27,00

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -

More information

Low Profile Unit Coolers

Low Profile Unit Coolers Bulletin 306.0D August 2004 (Replaces 306.0C 3/04) Low Profile Unit Coolers Model ADT - Air Defrost Model LET/LLE - Electric Defrost Model HGT - Hot Gas Defrost Front access to refrigeration components.

More information

LUI / LUO. Condensing Units

LUI / LUO. Condensing Units UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component

More information

Levitor II. AIR-COOLED CONDENSER (Available for Fluid Cooler Applications) Technical Bulletin: LEVC_003_030817

Levitor II. AIR-COOLED CONDENSER (Available for Fluid Cooler Applications) Technical Bulletin: LEVC_003_030817 Levitor II IR-COOLED CONDENSER (vailable for Fluid Cooler pplications) Technical Bulletin: LEVC_003_030817 Products that provide lasting solutions. Table of Contents Benefits and Features 1 System Selection

More information

Lo-Profile Unit Coolers

Lo-Profile Unit Coolers Lo-Profile Unit Coolers Air & Electric Defrost North America www.tecumseh.com Lo-Profile Unit Coolers Air & Electric Defrost The Perfect Complement. The Lo-Profile (Air and Electric Defrost) Unit Coolers

More information

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost. CH-MPTB June 2015 Replaces CH-MPTB Nov 2010 MEDIUM PROFILE UNIT COOLERS Technical Guide s HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2

More information

Medium Profile Unit Coolers

Medium Profile Unit Coolers CH-MPTB JAN 2018 Replaces CH-MPTB AUG 2016 Medium Profile Unit Coolers Technical Guide s HMA HME/HML HMG/HMF Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...

More information

MEDIUM PROFILE UNIT COOLERS Technical Guide

MEDIUM PROFILE UNIT COOLERS Technical Guide BN-MPTB August 2016 Replaces BN-MPTB, June 2015 MEDIUM PROFILE UNIT COOLERS Technical Guide s BMA Air Defrost BME/BML Electric Defrost BMG/BMF Hot Gas Defrost heatcraftrpd.com Table of Contents Nomenclature...2

More information

CAPACITY BTU/H FAN DATA MOTORS 240V AMPS

CAPACITY BTU/H FAN DATA MOTORS 240V AMPS LP Series Cooler above 34 F AIR DEFROST CAPACITY BTU/H 10 FTD 15 FTD QTY CFM MOTORS R-404A CHARGE LPA-18-0380 3850 5775 1 940 2 0.72 32 LPA-18-0520 5200 7800 1 900 2 1.09 34 LPA-18-0610 6100 9150 1 860

More information

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER Publication No. RU-RLX-0817C Next-Gen All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost 4,100 to 45,900 BTUH Electric Defrost 2,700 to 33,000 BTUH Defrost

More information

Next-Gen All-Temp Low Profile Unit Cooler

Next-Gen All-Temp Low Profile Unit Cooler Publication No. WT-WLX-0918A Replaces WT-WLX-0618A Next-Gen All-Temp Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 4,100 to 45,900 BTUH Electric Defrost

More information

CAL / CEL / CDL / CGL / CKL

CAL / CEL / CDL / CGL / CKL CAL / CEL / CDL / CGL / CKL LOW PROFILE UNIT COOLERS > > CAPABILITIES: AIR DEFROST: 3,500-41,000 BTU/HR ELECTRIC DEFROST: 3,300-29,000 BTU/HR HOT GAS DEFROST: 3,300-29,000 BTU/HR www.coilexpert.com Partnership

More information

COMMERCIAL WALK-IN COOLERS AND FREEZERS

COMMERCIAL WALK-IN COOLERS AND FREEZERS COMMERCIAL WALK-IN COOLERS AND FREEZERS LSA Models Ideal for coolers above +34 F Low Silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 Btu/hr./10 F TD LSE, LSR and LST Models

More information

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. RU-RFH-1117A Replaces document RU-RFH-0917A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell

More information

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. RU-RFH-0117A Replaces document RU-RFH-0516A R-Series Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 1/2 TO 6 HP The Next Generation of MiniCons are Here! Russell

More information

Center Mount Unit Coolers

Center Mount Unit Coolers LK-CMTB JAN 2018 Replaces LK-CMTB JULY 2017 Center Mount Unit Coolers Technical Guide s ACM Air Defrost ECM Electric Defrost Table of Contents Nomenclature 2 Features & Benefits 3 Performance Data 4 Specifications

More information

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS Publication No. WT-WFH-1115B W-Series Next-Gen Proline 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS 2 W-Series The Next Generation of Prolines are Here! Witt s Next-Gen Proline W-Series ½

More information

Unit Cooler. Small to Medium Walk - Ins. Coolers & Freezer Applications

Unit Cooler. Small to Medium Walk - Ins. Coolers & Freezer Applications Now available with EC Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.15 November, 2008 Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot

More information

Vertical Air Discharge Condensing Units

Vertical Air Discharge Condensing Units BN-VADTB JUNE 2017 Replaces BN-VADTB AUG 2016 Vertical Air Discharge Condensing Units Technical Guide s BLV BDVS JLD JDDS Table of Contents Nomenclature........................................................................................................

More information

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER Bulletin LH-02 August 2002 (Replaces LH-98, March 1998) THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER Warehouse/Industrial Unit Coolers Larkin introduces it s latest line of warehouse/industrial

More information

Large Profile Unit Coolers

Large Profile Unit Coolers CH-LUCTB AUGUST 2018 Replaces CH-LUCTB MARCH 2018 Large Profile Unit Coolers Technical Guide s HHA HHE/HHL HHG/HHF Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...

More information

Consider The Possibilities...

Consider The Possibilities... FS/FD Air-Cooled Fluid Cooler Catalog 710.1 Consider The Possibilities... Cools most any non-corrosive fluid Closed-circuit cooling avoids contamination Cold weather economizer for interior cooling loads

More information

42HS Fan Coil Unit (High Static Pressure)

42HS Fan Coil Unit (High Static Pressure) 42S Fan Coil Unit (igh Static Pressure) Air Volume: 1360~3400m3/h Turn To The Experts Founded by the inventor of modern air conditioning, Carrier is the world s leader in high-technology heating, air-conditioning

More information

Remote Air Cooled Condenser

Remote Air Cooled Condenser Catalog KM-KDS-0313A UniCon Remote Air Cooled Condenser Kramer s Remote Air Cooled Condensers are designed to provide a wide array of solutions focusing on performance, energy efficiency, reduced sound

More information

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY TECHNICAL SPECIFICATIONS GP7RD Series Single Packaged Air Conditioner, Single Phase GP7RD 13 SEER, R-410A 2 thru 4 Ton Units Cooling: 24,000 to 47,000 Btuh The GP7 Series single packaged air conditioners

More information

Standard features. Optional features

Standard features. Optional features FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and

More information

Air-Cooled Fluid Cooler

Air-Cooled Fluid Cooler Catalog KM-FSD-0313A FS/ FD Series Air-Cooled Fluid Cooler Consider The Possibilities Cools most any non-corrosive fl uid Closed-circuit cooling avoids contamination Cold weather economizer for interior

More information

MAH. Modular Air Handling Unit

MAH. Modular Air Handling Unit MA Modular Air andling Unit 500 to 11,000 CFM @ up to 6.00 TSP 2 and 4 double wall construction, perforated or solid lined 18 gauge G0 galvanized steel cabinet 26 standard cabinet sizes available Internally

More information

Standard features. Optional features

Standard features. Optional features FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and

More information

Vertical Air Discharge Condensing Units

Vertical Air Discharge Condensing Units BN-VADTB NOVEMBER 2018 Replaces BN-VADTB JUNE 2018 Vertical Air Discharge Condensing Units Technical Guide s BLV BDVS JLD JDDS Table of Contents Nomenclature...................................................................................................

More information

Air Cooled Condensing Units - Technical Catalog. Featuring CopelandTM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring CopelandTM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring CopelandTM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com

More information

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 24CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 24,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö ^áêëçåâ=ìåáí=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö O `çåíéåíë= page Model indication................................ 2 Eurovent...................................... 2 Capacities.....................................

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3 MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model

More information

Nomenclature. Table of Contents. BH A 850 C P A Vintage

Nomenclature. Table of Contents. BH A 850 C P A Vintage bn-luctb May 2008 Replaces 430.2, August 2002 Large Unit Cooler Technical Guide s BHA Air Defrost BHE/BHL Electric Defrost BHG/BHF Hot Gas Defrost www.thecoldstandard.com Table of Contents Features & Benefits...

More information

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY TECHNICAL SPECIFICATIONS GQ5RD Series Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh Heating: 24,000 to 54,500 Btuh The GQ5 Series single packaged

More information

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH 48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position

More information

Concealed Ducted Split Series R22

Concealed Ducted Split Series R22 Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING

More information

TOTALINE REFRIGERATION CONDENSERS

TOTALINE REFRIGERATION CONDENSERS TOTALINE REFRIGERATION CONDENSERS P703 AIR-COOLED CONDENSERS AND DRY COOLERS Totaline s refrigeration condensers are used for refrigeration systems. These condensers are designed for large coolers or freezers.

More information

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

Product Data. 42D Ducted Fan Coil Air Conditioners cfm

Product Data. 42D Ducted Fan Coil Air Conditioners cfm Product Data 42D Ducted Fan Coil Air Conditioners 600-2000 cfm Carrier s 42D series ducted fan coil units offer design and equipment location flexibility Choice of 5 models, each available in 8 sizes For

More information

Complete HVAC Capability

Complete HVAC Capability Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option

More information

REMOTE AIR COOLED CONDENSERS

REMOTE AIR COOLED CONDENSERS Catalog KM-KDS-1017A Replaces document KM-KDS-0817A QUANTUM AIR REMOTE AIR COOLED CONDENSERS GOLD AWARD WINNER 2017 Best New Refrigeration Product 2 Quantum Air Efficient and Reliable Kramer s Remote Air

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH 36CWA4-HW 4-Pipe Chilled & Hot Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled & Hot Multi-Position Fan Coil 4-Pipe Nominal Size: 36,000 BTUH Multiaqua

More information

MEDIUM TEMP LOW PROFILE EVAPORATORS LB ELB Series

MEDIUM TEMP LOW PROFILE EVAPORATORS LB ELB Series MEDIUM TEMP LOW PROFILE EVAPORATORS LB ELB Series Standard Features: Low air velocity, even temperature and high humidity created by this unit makes it ideal for meat coolers, cutting and packaging, fresh

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 1½ thru 5 Ton Units Cooling: 17,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-08-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000

More information

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö fåçìëíêá~ä=~áê=åççäéêë= pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

Quantum Air REMOTE AIR COOLED CONDENSER

Quantum Air REMOTE AIR COOLED CONDENSER Publication No. RU-RDS-1017A Replaces document RU-RDS-0817A Quantum Air REMOTE AIR COOLED CONDENSER GOLD AWARD WINNER 2017 Best New Refrigeration Product 2 QUANTUM AIR Efficient and Reliable Russell s

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( ) 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (024-0) Product Data Fig. 1 - Unit 664B Single -Packaged Heat Pump Units with: S easy installation

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

TMP. Medium Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

TMP. Medium Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin T30--PDI-12 Part # 1082852 PRODUCT SUPPORT web: t-rp.com/tmp email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: Medium Profile Evaporator Air, Electric, Hot Gas

More information

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

ZEFIRO. The new dual discharge air cooler AIR HEAT EXCHANGER MANUFACTURER. stefani-online.it

ZEFIRO. The new dual discharge air cooler AIR HEAT EXCHANGER MANUFACTURER. stefani-online.it ZEFIRO AIR HEAT EXCHANGER MANUFACTURER ZEFIRO ZEFIRO is the new dual discharge air cooler for refrigeration applications, especially for processing rooms or environments that require a double flow of air.

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES

O5DMA-NRG O5DMA-NRG. Self-Contained Multi-Deck Merchandiser 4', 6', 8' & 12' (Dairy / Deli / Beverage / Produce) SHIPPING WEIGHT GENERAL NOTES GENERAL NOTES " - - -" indicates that the feature is not an option for this case model and/or the data is not yet available. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. 3rd

More information

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM

42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM 42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette

More information

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö = pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö O `çåíéåíë= page Model indication..................................2 Eurovent.......................................2 Capacities......................................2

More information

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION PRODUCT DATA & INSTALLATION Bulletin K30-KEP-PDI-2 Part # 1104191 PRODUCT SUPPORT web: k-rp.com/kep email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: KEP Extended Profile Evaporator Air, Electric,

More information

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the

More information

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

REFRIGERATION HEAT EXCHANGERS

REFRIGERATION HEAT EXCHANGERS REFRIGERATION HEAT EXCHANGERS SWEP COMPACT BRAZED HEAT EXCHANGERS (CBE s) Maximum Material Efficiency No dead zone outside gaskets because there is no need for gaskets. Up to 25% more capacity utilization

More information

Parts Price List Authorized Parts for Original Equipment

Parts Price List Authorized Parts for Original Equipment Bulletin IN-PL January 1 st 2018 Commercial Refrigeration Parts Parts Price List Authorized Parts for Original Equipment General Information 1. MINIMUM ORDER is $30.00 net billing 2. All prices are F.O.B.

More information

Parts Price List Authorized Parts for Original Equipment

Parts Price List Authorized Parts for Original Equipment Bulletin IN-PL July 1 st 2018 Commercial Refrigeration Parts Parts Price List Authorized Parts for Original Equipment General Information 1. MINIMUM ORDER is $30.00 net billing 2. All prices are F.O.B.

More information

Publication No. RU-QVX-0718A. QV-Series. 15 TO 100 HP AIR COOLED CONDENSING UNITS with Copeland Discus Compressors

Publication No. RU-QVX-0718A. QV-Series. 15 TO 100 HP AIR COOLED CONDENSING UNITS with Copeland Discus Compressors Publication No. RU-QVX-0718A QV-Series 15 TO 100 HP AIR COOLED CONDENSING UNITS with Copeland Discus Compressors 2 QV-SERIES Efficient and Accessible The design of the innovative QV-Series Condensing Units

More information

MAKING REFRIGERATION GREENER

MAKING REFRIGERATION GREENER Searle KME air cooler MAKING RERIGERATION GREENER The Searle KME cooler range from Kelvion is ideally suited to large cold rooms and small warehouses where an efficient cooling solution is required. The

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner

P7RF Series Two-Stage, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RF Series Two-Stage, Single Phase Packaged Air Conditioner 16 SEER, 12 EER 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P7 Series single packaged air conditioners are

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

1/2-6 HP Air-cooled Condensing Units

1/2-6 HP Air-cooled Condensing Units BN-HTSTB JAN 2018 Replaces BN-HTSTB OCT 2017 1/2-6 HP Air-cooled Condensing Units Technical Guide s BZ BH BS Table of Contents Nomenclature...2 Features & Benefits...3 Options...4 Hermetic s... 5-11 Performance

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

HEATING & COOLING COIL PRODUCTS

HEATING & COOLING COIL PRODUCTS HEATING & COOLING COIL PRODUCTS CC CEILING MOUNTED COOLERS Capacities 10-135k hite powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing HEATING & COOLING COIL PRODUCTS The CC range of ceiling mounted

More information

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN > > Used for small to medium Freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment

More information

Package Air Conditioners

Package Air Conditioners MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PPG2GI M1200 Product Line Single Packaged Gas/Electric Units 20 SEER, 81% AFUE 2-5 Ton Units Multi-Stage Cool / Two-Stage Heat The iq Drive gas/electric packaged system features

More information

Standard Features F N H S 01 H Product Line Vintage Model Width Fans Tube Diameter Rows Coil Model # S = Single D = Double.

Standard Features F N H S 01 H Product Line Vintage Model Width Fans Tube Diameter Rows Coil Model # S = Single D = Double. Overview Product Description Direct drive fluid coolers with vertical air flow are designed to save time on installation, provide excellent performance, long service life and a wide range of performance

More information

R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP

R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP Publication No. RU-REL-0414A Supersedes RU-REL -0413A R-Series DUAL REFRIGERANT AIR COOLED CONDENSING UNITS 1/2 TO 6-1/2 HP 1/2 to 3 HP 4 to 6 HP 2 DUAL REFRIGERANT AIR COOLED CONDENSING UNITS Description

More information

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h

GPC13H. 2- to 5-Ton Packaged Air Conditioner 13 SEER / R-410A. Cooling Capacity: 24,000-59,000 BTU/h ooling apacity: 4,000-59,000 BTU/h GP13H - to 5-Ton Packaged Air onditioner 13 SEER / R-410A Standard Features Energy-efficient compressor with internal relief valve PS blower motor; EEM blower motor on

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h DS ommercial - 5 Ton Packaged Air onditioner 4 SEE / Up to.0 EE ooling apacity: 5,000 58,000 BTU/h ontents Nomenclature... Product Specifications... 4 Expanded ooling Data... 7 Airflow Data... rankercase

More information

NH 3. Evaporator. Ammonia Applications Tons MANP

NH 3. Evaporator. Ammonia Applications Tons MANP NH 3 Evaporator Ammonia Applications 12-108 Tons > > Used for medium TO large Industrial Ammonia applications Manufactured with Stainless steel tubes. The Global Leader In Heat Exchange Technology With

More information

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES PRODUCT SPECIFICATIONS 4 SEER HEAT PUMP PACKAGED UNIT FORM NO. -00 (03/207) REFRIGERANT SYSTEM Environmentally friendly R40A refrigerant Copper tubing with enhanced fin coils Internal service gauge ports

More information

1/2-6 HP Air-cooled Condensing Units

1/2-6 HP Air-cooled Condensing Units CH-HTSTB JAN 2018 Replaces CH-HTSTB OCT 2017 1/2-6 HP Air-cooled Condensing Units Technical Guide s CZ CH CS Table of Contents Nomenclature...2 Features & Benefits...3 Options...4 Hermetic s... 5-11 Performance

More information