Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring

Size: px
Start display at page:

Download "Vibration Isolators (6) Galvanized Wheel. Sealed Ball Bearing. Standard Duct Size Inlet Ring"

Transcription

1 The Lau FGP Series Blower is perfect for use in ventilating, exhausting, air conditioning, processing and general industrial applications. Cold Rolled Steel: all welded construction with painted enamel finish. Wheels: forward curved delivers high static pressure at low tip speeds. Dynamically balanced assuring smooth operation. Galvanized material. Ball Bearings: for smoother running and extended life. Shafts: solid, ground and polished. Two Motor Mounting Positions: for each of the four basic discharge angles. Belt length remains the same regardless of discharge angle (10-18 sizes). Vibration Isolators: minimizes vibration and noise. Maximum Air Temperature: up to 150 F. : ,000 applications. Sizes: Standard Rotation: available in both CW and CCW rotation. Vibration Isolators (6) Galvanized Wheel Sealed Ball Bearing Standard Duct Size Inlet Ring CW Rotation (shown) Same Belt Length for all discharge positions (10 18 sizes) Two motor adjusting screws Part Wheel Shaft Tip Speed Outlet Max. Max. Number Model Rotation Diameter Diameter () Area HP FGP 10-6A CW x Ft FGP 10-6A CCW x Ft FGP 12-6A CW x Ft FGP 12-6A CCW x Ft FGP 15-9A CW x Ft FGP 15-9A CCW x Ft FGP 18-13A CW x Ft FGP 18-13A CCW x Ft FGP 22-11K CW x Ft FGP 22-11K CCW x Ft FGP 25-12K CW x Ft FGP 25-12K CCW x Ft FGP K CW x Ft FGP K CCW x Ft FGP 30-15K CW x Ft FGP 30-15K CCW x Ft DISCHARGE POSITIONS Rotation determined from drive side of blower Performance Charts begin on Page 29. CW Bottom Horizontal Downward Top Horizontal Upward CCW Bottom Horizontal Downward Top Horizontal Upward BLOWERS SHOWN HERE ARE LICENSED 27

2 DIMENSIONAL DATA CW ROTATION SHOWN FGP 10-6A, 12-6A, 15-9A & 18-13A CW ROTATION SHOWN FGP 22-11K, 25-12K, K & 30-15K Model A B C D E F G H J K L M R S T X Y Z FGP 10-6A FGP 12-6A FGP 15-9A FGP 18-13A FGP 22-11K FGP 25-12K FGP K FGP 30-15K Blower Shaft Parts Motor Ball Bearing Number Model Rotation Wheel Size Part No. Bag Mount I.D. Number CW FGP 10-6A CCW x CW FGP 12-6A CCW x CW & FGP 15-9A CCW x * CW & FGP 18-13A CCW x * CW FGP 22-11K CCW x CW FGP 25-12K CCW x CW FGP K CCW x CW FGP 30-15K CCW x * Requires one of each. NOTE: Weather covers are no longer available. FGP REPLACEMENT PARTS BLOWERS SHOWN HERE ARE LICENSED 28

3 FGP 10-6A CW & CCW BLOWER Performance Charts BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP FGP 12-6A CW & CCW BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP FGP 15-9A CW & CCW BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP Performance Data Performance is based on standard air (.075 lbs./cu. ft.). Operation in shaded area may result in fluctuating pressure. Power rating (BHP) does not include drive losses. Performance shown is for installation Type B-Free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. BLOWERS SHOWN HERE ARE LICENSED 29

4 Performance Charts BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP FGP 18-13A CW & CCW FGP 22-11K CW & CCW BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP FGP 25-12K CW & CCW BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP Performance Data Performance is based on standard air (.075 lbs./cu. ft.). Operation in shaded area may result in fluctuating pressure. Power rating (BHP) does not include drive losses. Performance shown is for installation Type B-Free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. BLOWERS SHOWN HERE ARE LICENSED 30

5 BLOWER Performance Charts BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP FGP K CW & CCW FGP 30-15K CW & CCW BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP BHP Performance Data Performance is based on standard air (.075 lbs./cu. ft.). Operation in shaded area may result in fluctuating pressure. Power rating (BHP) does not include drive losses. Performance shown is for installation Type B-Free inlet, ducted outlet. Performance ratings do not include the effects of appurtenances in the airstream. BLOWERS SHOWN HERE ARE LICENSED 31

6 Drive Guidelines & Drive Charts Pulleys: Belts: Motors: Use Cast Iron when motor is over 1 HP. Due to variations in pulleys, actual HP and should always be checked to prevent motor overload. 4L = FHP Belts A = A Section Standard Duty B = B Section Sets must be length matched All motors over 5 HP must be floor mounted. GENERAL DRIVE GUIDELES If Belt Length is not given, motor is to be floor mounted, only. Determine belt length by using the following formula: L = Pitch Length of Belt D = Pitch Dia. of Large Pulley (D - d) 2 L = 2C (D + d) + 4C C = Center Distance d = Pitch Dia. Small Pulley DRIVE CHARTS FGP 10-6A ADJ. BLOWER L L L L L L L L L T A T A FGP 12-6A ADJ. BLOWER L L L A L L T - 145T A T - 145T A T A FGP 15-9A ADJ. BLOWER L L L L T - 145T A T - 145T A T - 145T A T - 145T A BLOWERS SHOWN HERE ARE LICENSED 32

7 FGP 18-13A BLOWER Drive Charts ADJ. BLOWER L L L L L T - 145T A T - 145T A T - 145T A T - 145T A T A T A FGP 22-11K ADJ. BLOWER A A A T - 145T A T - 145T A T - 145T A T A T A T A T A T A T A T A T B T B T A T A FGP 25-12K ADJ. BLOWER B B T - 145T B T - 145T B T - 145T B T - 145T B T - 145T B T B T B T B T B T B T B T B T B T B T B T A T A T B BLOWERS SHOWN HERE ARE LICENSED 33

8 Drive Charts FGP K ADJ. BLOWER B T - 145T B T - 145T B T - 145T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B FGP 30-15K ADJ. BLOWER T - 145T B T - 145T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B T B BLOWERS SHOWN HERE ARE LICENSED 34

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572 FEATURES Computer designed, efficient performance, forward curved blower. Blower wheel hub is secured to the shaft with a locking keyway. Blower is secured to anti-vibration mounts within the cabinet.

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

Product Specification Sheet Number: 319

Product Specification Sheet Number: 319 A Series Class I Frame Blower Product Specification Sheet Number: 319 Notes: Shaded areas indicate Lau preferred product. Selections in non -shaded areas and optional features may affect price and availability.

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R MODEL BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial

More information

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN MODEL FEATURES Rated up to 20,000 CFM in static pressure applications up to 2-1/2 w.g. Motor drives are located outside of the airstream Ideal for applications where space is limited Belt drives permit

More information

TORIN by: AIRDEX Index Page No.

TORIN by: AIRDEX Index Page No. Index Page No. N Series Fans 2 Bladed, Heavy Duty...1 N Series Fans 3 Bladed, Free Air...2-3 N Series Fans 4 Bladed, Heavy Duty...4-5 Universal Hubs...6 One Piece Fan O Series 4 & 5 Bladed...7 One Piece

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MEL FEATURES Exhaust air up to 28,000 CFM in high static pressure applications up to 1-1/4 w.g. Attractive spun aluminum exterior Belt drives permit easy performance adjustments when needed Non-overloading

More information

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER Model Features Exhaust air up to 6,817 CFM in high static pressure applications up to 3 Belt drives permit easy performance adjustments when needed Nonoverloading backward inclined wheel for efficiency

More information

Product Specification Sheet Number: 305

Product Specification Sheet Number: 305 H Series Class I & II Frame Blower Product Specification Sheet Number: 305 Notes: Shaded areas indicate Lau preferred product. Selections in non-shaded areas and optional features may affect price and

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty MODEL FEATURES Exhaust air up to 2,800 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space is limited Non-overloading

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN R BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN APPLICATION s fans are primarily used for filtered make-up air in kitchen hood applications but may also be specified for make-up air in commercial and

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

200, 9200 & 9200-VIB SERIES

200, 9200 & 9200-VIB SERIES DUCT VENTILATION 200 SERIES Indoor Applications, Insulated or Non-Insulated 9200 SERIES Heavy duty, Insulated Indoor or Outdoor Applications SUBJECT TO CHANGE WITHOUT NOTICE - 04/7 Optional motor, drive

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODELS & e DIRECT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL - DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,980 CFM in high static pressure applications up to 1-1/2

More information

BLOWER PARTS & ACCESSORIES

BLOWER PARTS & ACCESSORIES BRACKET KITS NEW! BOLT ON BEARING BRACKET Replacement Bearing Brackets for Lau Belt Drive Blower (see Page 22). 9 Blower 054866-01 10 Blower 054867-01 11 Blower 054868-01 12 Blower 054869-01 SERVICE TIP:

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODELS & e DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS MODEL DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 4,780 CFM in high static pressure applications up to 1-1/2 w.g. Attractive

More information

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: HDBI BLOWERS OEM and Industrial Air Handling Specialist BACKWARD INCLINED CLASS II CLASS III CLASS IV 797 Snider Road, Mason, OH 45040-915 Telephone: 51-57-000 Visit us at www.cincinnatifan.com for more

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating

More information

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SQUARE INLINE CENTRIFUGAL FANS

SQUARE INLINE CENTRIFUGAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS SQUARE INLINE CENTRIFUGAL FANS DSI BSI CATALOG 40 FEBRUARY 07 SQUARE INLINE CENTRIFUGAL FANS Overview DSI BSI Twin City Fan & Blower

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS COMMERCIAL KITCHEN APPLICATIONS Belt Driven Model VRBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

Air Moving Products & Accessories. air Catalog. featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC.

Air Moving Products & Accessories. air Catalog. featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC. air Air Moving Products & Accessories 2006 Catalog featuring...gates Belts FAN BLADES BLOWER WHEELS ACCESSORIES V-BELTS ADAPTER HEX HUBS ETC. IR MARS AIR MOVING COMPONENTS AIR MOVING COMPONENTS AN BLADES

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 705) File no. E40001 and for grease removal (UL/C-UL US 762) File no. MH11745. Accurex, LLC certifies model XRUB, XRUD, XSEB,

More information

K SERIES SIDEWALL PROPELLER FANS

K SERIES SIDEWALL PROPELLER FANS K SERIES S Models LWBK/LMBK and LRBK/LNBK K SERIES S The Carnes Sidewall Propeller Fan series Models LW/LM and LR/LN have been designed for quiet and efficient air flow performance with the lowest possible

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

EXHAUST FANS CUD & CUB UPBLAST FANS

EXHAUST FANS CUD & CUB UPBLAST FANS EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

DESIGN GUIDELINES FANS PAGE 1 of 7

DESIGN GUIDELINES FANS PAGE 1 of 7 DESIGN GUIDELINES FANS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification to the

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0415 April 2015 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal Upblast Power Roof Ventilators

Centrifugal Upblast Power Roof Ventilators INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Upblast Power Roof Ventilators TYPE UBCA - BELT DRIVE TYPE UDCA - DIRECT DRIVE TABLE OF CONTENTS UBCA Sizes 06 to 44 Flow rates from 229 to 29,002 CFM

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Direct and Belt Driven Models VUDK and VUBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company

More information

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN TUBEAXIAL INLINE BELT RIVEN UCT FAN Model Features Rated up to 75,490 CFM in static pressure applications up to 1-1/2 w.g. 12 sizes ranging from 12 to 60 propeller diameters Motor drives are located outside

More information

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS S CSF & LSF Model CSF Hooded Design FEATURES Supply air to over 13,000 CFM in static pressure capabilities to 2 w.g. Heavy-galvanized construction Belt drives permit easy performance adjustments when needed

More information

CONSTRUCTION FEATURES AND OPTIONS

CONSTRUCTION FEATURES AND OPTIONS MODEL SQD & esqd MODEL FEATURES Exhaust air up to 2,8 CFM in high static pressure applications up to 1 w.g. Direct drive units have low sound levels and quiet operation Ideal for applications where space

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0116 January 2016 Centrifugal Spun Aluminum Line Overview

More information

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products Centrifugal Spun Aluminum Products SDB SDBD STXB STXD Downblast & Upblast Centrifugal Roof Wall Exhausters Designed with Efficiency in Mind CSAP_0317 March 2017 Centrifugal Spun Aluminum Line Overview

More information

Filtered Kitchen Supply Packaged Ventilator

Filtered Kitchen Supply Packaged Ventilator Filtered Kitchen Supply Packaged Ventilator Page Introduction........................................... 2 Information............................................ 3 Specifications and Dimension Data KD................................................

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL CENTRIFUGAL UPBLAST ROOF EXHAUSTERS HIGH TEMPERATURE SMOKE EXHAUST APPLICATIONS Belt Driven Model VQBL DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS SECTION

More information

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS SECTION 11 OPTIONAL ACCESSORIES VXDAF filter sections are insulated and supplied with 1 framed aluminum mesh filter.

More information

CENTREX INLINER Centrifugal Inline Fans

CENTREX INLINER Centrifugal Inline Fans CENTREX INLINER Centrifugal Inline Fans TECHNICAL SPECIFICATIONS BULLETIN SX8 PennBarry Your Single Source for Commercial & Industrial Supply & Exhaust Fans www.pennbarry.com TABLE OF CONTENTS INTRODUCTION

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

Belt Drive Blowers - Double Inlet (Less Motor & Drive Package) Warranty: 1 year limited

Belt Drive Blowers - Double Inlet (Less Motor & Drive Package) Warranty: 1 year limited 30/10/15 A15 Blowers Belt Drive Blowers - Double Inlet (Less Motor & Drive Package) For specific air volume and pressure requirements Blower wheel features an exclusive centre disc which safely allows

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

Roof Upblast and Sidewall Exhaust

Roof Upblast and Sidewall Exhaust XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and

More information

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application CAT.NO. 120-97 SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application TABLE OF CONTENTS Introduction......3 Selection Examples......4-5 Correction Factors......6 Rating Tables.........7-17

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

Industry best 5 year fan housing warranty, 1 year motor warranty

Industry best 5 year fan housing warranty, 1 year motor warranty MODEL RED MODEL FEATURES Exhaust air up to 3,000 CFM in high static pressure applications up to 1 w.g. Attractive spun aluminum exterior Direct drive units have low sound levels and quiet operation Non-overloading

More information

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS

MARINE DUTY TUBEAXIAL & VANEAXIAL FANS BULLETIN 420 November 2000 MARINE DUTY TUBEAXIAL & VANEAXIAL FANS Type MD Direct Drive Model MDTM, MDVM & MDVH Marine Duty Tubeaxial and Vaneaxial Fans Aerovent s Marine Duty Fans feature medium and high

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 370 January 2007 AIRFOIL FANS TYPE BAE SWSI and DWDI BAE SWSI and DWDI Airfoil Fans Featuring the E-Series Wheel This catalog features the new BAE airfoil wheel design.

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes

More information

MIN/MAX PERFORMANCE IN INCHES WG

MIN/MAX PERFORMANCE IN INCHES WG Fans Roof Exhaust Direct Drive - G Model G Centrifugal Roof Exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL TUB MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

Centrifugal Filtered Supply Roof Blowers

Centrifugal Filtered Supply Roof Blowers CFS Centrifugal Filtered Supply Roof Blowers Page Introduction...................................... 2 Specifications and Dimension Data................... 3 Typical Installation................................

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories IRECT RIVE TUBEAXIAL FANS Model LIA Model LIA IRECT RIVE TUBEAXIAL FANS SECTION 12 Application Carnes Company tubeaxial fans offer one of the widest ranges of sizes, horsepower and performance in the industry.

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS MODEL FEATURES Exhaust air to over 40,000 CFM up to 3/4 w.g. Belt drives permit easy performance adjustments when needed Direct drive units have low sound levels and quiet operation. Reversible blades

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER MODEL MODEL FEATURES Exhaust air up to 60,116 CFM in static pressure applications up to 1 w.g. Straight-through air flow design results in maximum exhaust efficiency Motor and drives are located outside

More information

FIXED PITCH PROPELLER FANS

FIXED PITCH PROPELLER FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin

More information

Propeller Upblast Roof Fans

Propeller Upblast Roof Fans Propeller Upblast Roof Fans Models RBU, RBUMO, RDU and RGU Direct Drive, Belt Drive and Gravity April 2010 Propeller Upblast Roof Fans Greenheck upblast propeller fans are designed to discharge contaminants

More information

Your Clean Air Source!

Your Clean Air Source! Direct Drive Your Clean Air Source! HIGH QUALITY... HIGH FFICINCY... VRSATILITY stablished in 1893, Peerless Blowers has a well established record of manufacturing a complete line of heavyduty industrial

More information

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

Phoenix Manufacturing, Inc E. Roeser Rd. Phoenix, AZ phoenixmanufacturing.com

Phoenix Manufacturing, Inc E. Roeser Rd. Phoenix, AZ phoenixmanufacturing.com 3655 E. Roeser Rd. Phoenix, AZ 85040 phoenixmanufacturing.com 602-437-1034 MODELS: SPECIFICATION DATA INDUSTRIAL AEROCOOL 12 & 8 MODELS ID/IS 500 w/ WS080 or WS100 or WS144 ID/IS 601 w/ WS080 or WS100

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

CAST ALUMINUM PRESSURE BLOWERS

CAST ALUMINUM PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CAST ALUMINUM PRESSURE BLOWERS TPD TPB CATALOG 820 JANUARY 2013 PRESSURE BLOWERS Models TPD TPB Twin City Fan & Blower s Cast Aluminum

More information

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS

MODELS FF & FFC CEILING AND INLINE/CABINET VENTILATORS Model FF Model FFC Model ff Features Exhaust air up to 1500 CFM Forward curve centrifugal wheel for high static pressure capabilities to 1 w.g. Resilient mount, low RPM motor for quiet operation (except

More information

Advancing Ventilation

Advancing Ventilation Centrifugal oof Sidewall LPD CWD STXD STXDe SDBD SDBDe SDB STXB Direct Drive Belt Drive Centrifugal oof Sidewall Fans Advancing Ventilation centrifugal-roof--sidewall-0219 February 2019 MODEL LPD LOW POFILE

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

FILTERED SUPPLY CENTRIFUGAL Belt Drive

FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL Belt Drive FILTERED SUPPLY CENTRIFUGAL - BELT DRIVE SECTION 9 Carnes Models VSBB and VHBB centrifugal filtered roof supply fans are available in six sizes - 8 through 20 with

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

Axial Propeller Panel Fans, PAF-Series

Axial Propeller Panel Fans, PAF-Series Axial Propeller Panel Fans, PAF-Series TABLE OF CONTENTS 3 Introduction 4 Certifications & Listings 4 Options & Accessories 9 Motor Availability 11 Direct Drive Dimensional & Performance Data 14 Belt Drive

More information

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group VERANTIS Environmental Solutions Group FRP Fans: CMHB Series 6-8-10 Performance and Technical Information Bulletin 11-6 Rev May 2013 VERANTIS Environmental Solutions Group Verantis Environmental Solutions

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4050 November 2009 DOWNBLAST ROOF EXHAUSTERS TYPE DCRD / BCRD (Spun Aluminum Housing) TYPE BCRD-E (Endurex Polymeric Housing) Downblast Roof Exhausters Twin City Fan & Blower

More information

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER MODEL FEATURES Exhaust air up to 52,000 CFM in static pressure applications up to 3/4 w.g. Motor and drives are located outside of the exhaust

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information