1 Appendix B. Chapter 11. Fan Housing Vibration Caused by Resonance Application of Modal & Vibration Analysis Ken Singleton KSC Consulting LLC

2 Background Four FD fans were installed at the site to meet environmental requirements of the process. The fan design details were as follows: 1500 HP Direct Drive AMCA Arrangement 8 Inlet Guide Vane Control Spherical Roller Bearings, Grease Lubricated PLC Monitoring and Control KSC Consulting LLC 11B-1

3 Flow 363,794 ACFM Gas Temp 130 degrees F Winter 250 degrees F Summer 1888 lb f 1560 HP, 1194 RPM 8042 lb f SKF CCK/W33 SKF CCK/W33 Max. Thrust Load 3209 lb f Figure 1. Schematic of Fan with some Parameters Labeled 11B-2

4 Background The fans experienced many reliability problems during the 1 st year of operation. These problems included: Bearing failures on each fan A catastrophic bearing failure on #1 Fan resulting in a broken motor shaft and damaged fan shaft, which required replacement. High bearing operating temperatures. Several lubrication greases were tried including varying quantity and interval of greasing as well as grease removal from the bearing housings. A small oil recirculation system was installed on one fan, but only provided mixed results Component fatigue failures of discharge vane assembly, 11B-1

5 Initial Assessment The initial assessment of the fans was made in Dec Numerous deficiencies were identified: The Fan End Bearing was operating at 92% of maximum recommended speed with grease lubrication. The spherical roller bearings calculated to be marginal for grease lubrication for the fan operating speed of 1194 RPM. Fan housing high amplitude vibration (access to housing limited by insulation.) The discharge vane housings exhibited high levels of vibration and cracking of welds at the linkage/shaft interfaces. Vibration analysis indicated lubrication-related high energy vibration (CSI PeakVue data) caused by bearing roller skidding (Bearing load less than specified minimum load.) 11B-2

6 Initial Assessment Initial Recommendations included the following: Perform a modal test of one fan housing. Change bearing lubricant from grease to oil and Install an oil re-circulating system with filtering and temperature control (The fan end bearings were operating at 92% of recommended maximum speed with grease lubrication (borderline for grease; this design truly needed oil lubrication). 11B-2

7 During second visit to site Feb Bearing & fan housing vibration was measured. A single accelerometer was attached to the fan housing though a hole drilled in the insulation. Minimum 1.2 in/sec was present. Inlet Guide Vanes Closed Guide Vane settings adjusted in 10% steps. Inlet Vanes 100% Fan Startup Vibration lowest level at 30% to 70% guide vanes open. Figure 2. Overall Vibration (in/sec) of Fan #4 Housing Measured Prior to Startup of the Fan and During Inlet Guide Vane Adjustments to Full Open, Closed and Shut Down. 11B-3

8 Frequency Spectrum in February 2002 on Fan #4 Housing Broad Base, Indicator of Resonance (at Fan Speed of 1194 RPM) Figure 3. Fan #4 Housing Vibration Spectrum. Most Vibration Energy was at about 20 Hz (1200 CPM), or 1 X Fan Running Speed (2.5 in/sec). The Response Appeared to be Caused by Resonance of the Housing. 11B-4

9 Fan Inspection After Insulation Removed Recommendation to perform fan housing modal test was accepted and scheduled for Sept 11-12, Insulation was removed to provide access to the fan housing. The fan housing was inspected for cracking as well as general design and fabrication methods. 13 Feet No cracks were found. Illustration A. Overview of Scrubber Fans Evaluated 11B-4

10 Fan Inspection After Insulation Removed The housing was a three piece design to permit shipping and removal of the fan wheel. Vertical Split The two upper sections were bolted to the lower half at the centerline and to each other at a vertical flange. Horizontal Split It was learned that sections of the housing flanges (4 inch Channel) had been removed using a cutting torch to provide clearance for the shaft. The removal of these stiffeners in the center of the housing significantly reduced the rigidity of the housing. 11B-5 Figure 5. Fan Housing Showing Vertical and Horizontal Joints and Intersection Near the Fan Centerline

11 Figure 4. The Drawing by the Fan OEM Indicates the Vertical and Horizontal Flanges were Designed to be Very Close to the Shaft. Extending Lines for the Vertical and Horizontal Flanges Indicate Potential Shaft Interference. 11B-5

12 Figure 6. Groove Worn In Fan Shaft Caused by Continuous Contact With Rubber Air Seal. Note Fan Housing Structural Members of 4 Channel Cut with Torch to Provide Fan Shaft Clearance. 11B-5

13 Modal Test 195 Test measurement points (DOF) were laid out in a mesh as shown in the photos. Excitation was by impact using a PCB Instrumented 12 lb Sledge Hammer. 5 Accelerometers were roved to each DOF. Figure 7. Mitch France - Laying Out Modal Test Points on Fan Housing, Shaft Inlet Side 11B-6

14 ME scopeves Model 11B-7

15 ME scopeves Model DOF s (195 DOF Measured) DOF 45X Driving Point 6X/6X Illustration B. 11B-7

16 Driving Point Frequency Response Function (FRF) taken on the fan housing showed many Natural Frequencies. There was a very responsive natural frequency at 1290 CPM (21.5 Hz) near Fan 1X running speed, which turned out to be the primary problem. Fan 1X Fan 2X 1290 CPM 3300 CPM Figure 9. Frequency Response Function (FRF) of Housing Inertance Magnitude Plot (g/lb f ) Copyright 2005: Technical Associates of Charlotte P.C. 11B-8

17 Figure 10 shows a Spectrum taken on Driving Point 6X with the fan running. Showed high vibration of 1.10 in/sec at 1 X Fan speed on fan housing. Also showed a notable level of.384 in/sec at 3150 CPM (near the 2 nd Mode identified in Figure 9) CPM 1.1 in/sec One - OFF ROUTE MACHINE OFF ROUTE -ORP OFF ROUTE MEASUREMENT POINT DATA 3150 CPM.384 in/sec ROUTE SPECTRUM 12-Sep-02 17:11:52 OVERALL= 1.38 V-DG PK = 1.37 LOAD = 30.0 RPM = RPS = Frequency in CPM ROUTE WAVEFORM 12-Sep-02 17:11:52 PK = 1.06 PK(+) = 1.77 PK(-) = 2.08 CRESTF= 2.77 Velocity in In/Sec PK Velocity in In/Sec Time in msecs Label: Pt 6X Steel Angle Removed Freq: Ordr: Spec: Figure 10. Vibration at DOF 6X which was the Modal Test Driving Point Location. Most Vibration was Found at 1200 and 3150 CPM (20.0 and 52.5 Hz). 11B-7 11B-8

18 Fan Housing Mode Shapes M # 6 < 6 X + : 6 X + > T r a c e E E E E ( E ) H z ( E ) Figure 11. Driving Pt 6X/6X, Cursor on 1277 CPM (21.28 Hz) Mode CPM (21.28 Hz) The housing was moving in and out perpendicular to the shaft axis due to cut stiffeners. Figure 12. Mode Shape at 1277 CPM (21.28 Hz). This Circular Mode was the Primary Contributor to Fan Housing Vibration. DOF 8 1 st Circular Mode Shape (near 1194 RPM fan running speed). Max vibration. measured during the test was DOF 8X at 1.72 ips (near the fan housing cutout where the shaft passes through the housing - see Illustration B). 11B-10

19 Fan Housing Mode Shapes M # 6 < 6 X + : 6 X + > T r a c e E E E E ( E ) H z ( E ) Figure 13. Driving Pt 6X/6X, Cursor on 2449 CPM (40.8 Hz) Mode CPM (40.8 Hz) The housing motion is out of phase on each side of the housing centerline. Figure 14. Mode Shape at 2449 CPM (40.8 Hz) is near 2 X Fan Speed. DOF 45 Discharge nozzle participates in the mode fatigue failure of welds. Max vibration. measured during the test was DOF 45 at ips (see Illustration B). 11B-11

20 Fan Housing Mode Shapes M # 6 < 6 X + : 6 X + > T r a c e E E E E ( E ) H z ( E ) Figure 15. Driving Pt 6X/6X, Cursor on 3299 CPM (55.0 Hz) Mode CPM (55.0 Hz) The housing motion is out of phase each side of the centerline. Figure 16. Mode Shape at 3299 CPM (55.0 Hz). This was the 2 nd Most Responsive Mode. DOF 45 Discharge nozzle does not participate in the mode. Max vibration. measured during the test was DOF 45 at ips. 11B-12

21 Fan Housing Mode Shapes M # 6 < 6 X + : 6 X + > T r a c e E E E E ( E ) H z ( E ) Figure 17. Driving Pt 6X/6X, Cursor on 4713 CPM (78.55) Hz Mode CPM (78.65 Hz) Primarily panel circular mode left side of housing. Figure 18. Mode Shape at 4713 CPM (78.65 Hz). Note Motion on Left Side of Blower Housing. DOF 45 Max vibration measured during the test was DOF 45 at 0.10 ips. 11B-13

22 Fan Housing Mode Shapes M # 6 < 6 X + : 6 X + > T r a c e E E E E ( E ) H z ( E ) Figure 19. Driving Pt 6X/6X, Cursor on 9580 CPM (159.7 Hz) Mode CPM (159.7 Hz) Primarily panel circular modes of the fan housing. Figure 20. Mode Shape at 9580 CPM (159.7 Hz). Primarily Panel Bending Modes of Fan Housing. DOF 45 Max vibration measured during the test was DOF 45 at ips. 11B-14

23 After the Modal Test, a Temporary 4 x 4 Angle was Clamped to the Fan Housing and the Fan was Restarted. 4 X4 Angle C- Clamped to Fan Housing Channel Figure 21. Vibration was Taken With & Without the Angle Attached to the Housing. 11B-15

24 Fan Running with Temporary 4 x 4 Angle clamped to the fan housing. Vibration was predominantly at DOF 6X (Illustration B). Temporary stiffener did prove to be effective in reducing vibration One - OFF ROUTE MACHINE OFF ROUTE -ORP vs OFF ROUTE -ORP angle clamped to housing No Angle Clamped to Comparison Spectrum OFF ROUTE -ORP 12-Sep-02 17: Reference Spectrum OFF ROUTE -ORP 12-Sep-02 16:58 PK Velocity in In/Sec 1 X Fan Fan Housing (1.1 ips) 4 x 4 x ½ Angle Clamped to Fan Housing (0.45 ips) 4 X 1/2 " Angle Clamped to Housing Frequency in CPM Label: Pt 6X Steel Angle Removed Freq: Ordr: Sp 2: B-15

25 Scrubber Fan, Comparsion of Housing Vibration With/Without 4X4 Angle Stiffener Clamped To Housing 1200 CPM Frequency (September 2002) X 7X 8X 45X 43X 78X 82X 66X 9X 10X 11X 69X 85X M e a sur e me nt Loc a t i on Angle St if f ener Clamped To Housing No Angle St if f ener Clamped To Housing Chart 1. Vibration at 1200 CPM Frequency with Temporary Angle Clamped to Housing Acting as a Stiffener (Blue) and the Angle Removed (Yellow). 11B-16

26 Recommendations Stiffening the fan housing to control the primary resonant amplification at 1277 CPM (21.28 Hz) was the major focus. Structural steel stiffeners bolted and welded to the housing were proposed as follows: 1. Bolt Two 4 x 4 Angle to the housing above the bearings to control the primary mode. Use bolted attachment to permit removal of the housing section for fan wheel access. 2. Weld a 4 x 4 Angle to the housing below the centerline to help control the primary mode at 1277 CPM (21.28 Hz). 3. Weld ½ x 4 Bar stiffeners to control panel modes. 11B-17

27 4 x ½ Plate Stiffeners welded to the housing and existing angle. Figure 22. Fan Housing Stiffening Recommendations. Two 4 x 4 x 86 angle bolted to the existing vertical angle and channel. Two 4 x 4 pieces of angle welded to the housing and existing channel. 4 x ½ Plate Stiffeners welded to the housing and existing angle. 11B-17

28 A site visit in Dec 2004, two years after the modal test, provided an opportunity to recheck vibration and the structural modifications that were actually made to the fan. 4 X 4 angle Bolted to Fan Housing Figure B-18

29 Initial vibration measured 1.6 in/sec, pk at 40% inlet guide vane setting. After angle was bolted to the housing, vibration was reduced to 0.15 in/sec, Pk at 1X, showing a 10.7:1 reduction (91% decrease) One - Scrubber Fan Four Fan 4 -F2A Fan Outboard Axial After Correction Comparison Spectrum Fan 4 -F2A 07-Dec-04 11: X Fan (0.15 in/sec) Before Correction Reference Spectrum Fan 4 -F2A 27-Feb-02 10:03 PK Velocity in In/Sec 1.0 1X Fan (1.6 in/sec) Frequency in CPM Label: Fan Housing Axial Figure 24. Comparison of Before and After Vibration Spectra Measured on Fan #4 Housing, DOF 6X at Fan Housing Split Line Structural Member. 11B-18

30 Initial Fan 1X vibration measured 1.6 in/sec, pk at 40% inlet guide vane setting. After angle was bolted to the housing, vibration was reduced to 0.15 in/sec, Pk at 1X, showing a 10.7:1 reduction (91% decrease) One - Scrubber Fan Four Fan 4 -F2A Fan Outboard Axial Fan 1X Run Speed Analyze Spectrum 07-Dec-04 11:43: Housing Resonance PK =.3532 LOAD = RPM = (19.90 Hz) 0.10 PK Velocity in In/Sec 0.05 The resonance is still excited by air flow; But the amplitude was reduced to only about 0.1 in/sec, pk (was 0.32 in/sec, pk) Frequency in CPM Label: Fan Housing Axial Freq: Ordr: Spec: Figure 25. The Housing Vibration after Angle Bolted to Housing. Spectrum Shows the Housing Natural Frequency has Increased from Approximately 1277 CPM to 1462 CPM (20.0 to 24.4 Hz). 11B-19

31 The resonance is still present but is shifted 14.5% higher in frequency away from fan running speed. After modifications, the Mode measured 1462 CPM or 22.0% from Fan 1X. Prior to modifications, the Mode measured 1277 CPM or 6.5% from Fan 1X One - Scrubber Fan Four Fan 4 -F2A Fan Outboard Axial Fan 1X Run Speed Analyze Spectrum 07-Dec-04 11:43: Housing Resonance PK =.3532 LOAD = RPM = (19.90 Hz) 0.10 Housing Natural Frequency Shifted from 1277 to 1462 CPM. PK Velocity in In/Sec Frequency in CPM Label: Fan Housing Axial Freq: Ordr: Spec: Figure 25. The Housing Vibration after Angle Bolted to Housing. Spectrum Shows the Housing Natural Frequency has Shifted from Approximately 1277 CPM to 1462 CPM (21.3 to 24.4 Hz). 11B-19

32 CONCLUSIONS: 1. The vibration and modal test data confirmed the suspected structural resonances of the fan housing. 2. During original installation of the fans, the mating joint flanges at the center of the housing had been removed by a cutting torch to provide clearance for the shaft. The removal of these stiffeners significantly reduced rigidity of the shaft entry side of the fan housing. 3. Most housing vibration response was at five natural frequencies 1277, 2449, 3299, 4713 and 9600 CPM. Excitation of the 1277 CPM mode was the primary contributor to housing vibration. The 3299 CPM mode was the 2 nd most responsive. 4. During the modal test, the inability to isolate the fan from air leakage caused significant housing vibration. This background vibration made it more difficult to obtain high quality modal test data. A medium sledge modal hammer was too small to input enough force to excite the housing above the background vibration. An instrumented sledge hammer was required to input the 1500 to 2000 lb f necessary to excite the housing. 11B-20

33 CONCLUSIONS: 5. The modal test data were curve fit to determine the mode shapes of the housing natural frequencies. After reviewing the mode shapes, it was decided to attach a temporary stiffener of 4 x 4 inch angle to the vertical flanges of the housing using heavy duty C clamps. Vibration data taken with the angle stiffener clamped to the housing showed that vibration of the 1277 CPM resonant response would be lowered significantly if stiffening at the proper locations was added. 6. Recommendations were made to bolt and weld structural members to the fan housing based on review of the mode shapes (see Figure 23). 7. After the stiffeners were installed, the vibration levels were reduced from about 1.6 in/sec to 0.15 in/sec, (91% reduction). The fan housing 1 st mode shifted from about 1277 CPM to 1462 CPM providing a separation margin of 22.5% from running speed (see Figures 24 and 25). 8. This project took approximately three years from initial inspection of the fans, recommendation to perform modal testing, conducting the modal test, installing the housing stiffeners and rechecking vibration. 11B-20

34 Acknowledgement: Thanks to Mitchell France of Technical Associates of Charlotte, PC for assistance with the modal test, data reduction and formulating a solution. Copyright 2005: Technical Associates of Charlotte P.C. 11B-20

35

BY: Paul Behnke ITT Industries, Industrial Process. Juan Gamarra Mechanical Solutions, Inc.

BY: Paul Behnke ITT Industries, Industrial Process. Juan Gamarra Mechanical Solutions, Inc. DRIVE SHAFT FAILURE ANALYSIS ON A MULTISTAGE VERTICAL TURBINE PUMP IN RIVER WATER SUPPLY SERVICE IN A NICKEL AND COBALT MINE IN I MADAGASCAR -BASED ON ODS AND FEA Juan Gamarra Mechanical Solutions, Inc.

More information

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 1

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 1 11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 1 Kevin R. Guy, Delaware Analysis Services, Inc., Francisco, Indiana This two-part article covers a series of eleven machinery

More information

PERFORMANCE LOSS INVESTIGATION USING THERMAL IMAGING

PERFORMANCE LOSS INVESTIGATION USING THERMAL IMAGING 283 PERFORMANCE LOSS INVESTIGATION USING THERMAL IMAGING PRESENTER AND AUTHOR: SCOTT MCPHERSON LEAD FIELD ENGINEER SULZER PUMPS (US) INC Tel: 281 417 7109 E-MAIL: Scott.Mcpherson@Sulzer.com ABSTRACT An

More information

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY 135 CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY 6.1 INTRODUCTION Shock is often defined as a rapid transfer of energy to a mechanical system, which results in a significant increase in the stress,

More information

Continuous Journey. Regreasing of Bearings. Risk Calculation Methodology. the magazine for maintenance reliability professionals

Continuous Journey. Regreasing of Bearings. Risk Calculation Methodology. the magazine for maintenance reliability professionals the magazine for maintenance reliability professionals Continuous Journey RELIABILITY ENGINEERING Risk Calculation Methodology The seasons of Hibbing Taconite s journey to high-performance reliability

More information

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR John J. Yu, Ph.D. Nicolas Péton Sergey Drygin, Ph.D. GE Oil & Gas 1 / Abstract This case is a site vibration issue on a Gas compressor module.

More information

Root Cause Analysis of a vibration problem in a propylene turbo compressor. Pieter van Beek, Jan Smeulers

Root Cause Analysis of a vibration problem in a propylene turbo compressor. Pieter van Beek, Jan Smeulers Root Cause Analysis of a vibration problem in a propylene turbo compressor Pieter van Beek, Jan Smeulers Problem description A newly installed turbo compressor system for propylene showed vibrations in

More information

COAL MINING EQUIPMENT VIBRATION ANALYSIS RESULTS OF ELEVEN YEARS SHOP TESTING. Ken Singleton

COAL MINING EQUIPMENT VIBRATION ANALYSIS RESULTS OF ELEVEN YEARS SHOP TESTING. Ken Singleton COAL MINING EQUIPMENT VIBRATION ANALYSIS RESULTS OF ELEVEN YEARS SHOP TESTING Ken Singleton Manager KSC Consulting LLC, Bristol VA ksingleton@vibrationconsulting.com Abstract: Rotating equipment used in

More information

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION F2004F461 AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION 1 Badiola, Virginia*, 2 Pintor, Jesús María, 3 Gainza, Gorka 1 Dana Equipamientos S.A., España, 2 Universidad Pública de Navarra,

More information

VALVE-INDUCED PIPING VIBRATION

VALVE-INDUCED PIPING VIBRATION Proceedings of the ASME 2011 Pressure Vessel and Piping Division Conference PVP2011 July 17-21, 2011, Baltimore, Maryland PVP2011-57391 VALVE-INDUCED PIPING VIBRATION Michael A. Porter Porter McGuffie,

More information

ME scope Application Note 24 Choosing Reference DOFs for a Modal Test

ME scope Application Note 24 Choosing Reference DOFs for a Modal Test ME scope Application Note 24 Choosing Reference DOFs for a Modal Test The steps in this Application Note can be duplicated using any ME'scope Package that includes the VES-3600 Advanced Signal Processing

More information

Contents 1) Vibration situation for CGC Large Steam Turbine 2) Root cause analysis and evaluation method 3) Countermeasure with result

Contents 1) Vibration situation for CGC Large Steam Turbine 2) Root cause analysis and evaluation method 3) Countermeasure with result Preface A Large Steam Turbine had been in operation for several years and this turbine experienced the wear damage of governor linkage. Then, measured the vibration velocity profile on Governor side pedestal

More information

Advanced Maintenance Technologies

Advanced Maintenance Technologies Advanced Maintenance Technologies Vibration Analysis Consultants Ray W. Wonderly Certified Vibration Specialist Services: Vibration Analysis Consulting Laser Alignment Services Predictive/Planned Maintenance

More information

ACOUSTIC AND VIBRATION ANALYSIS OF FLUID INDUCED BLOWER AND PIPING UNWANTED MOTION

ACOUSTIC AND VIBRATION ANALYSIS OF FLUID INDUCED BLOWER AND PIPING UNWANTED MOTION Proceedings of the ASME 2011 Pressure Vessels and Piping Division Conference PVP2011 July 17-21, 2011, Baltimore, Maryland, USA PVP2011-57017 ACOUSTIC AND VIBRATION ANALYSIS OF FLUID INDUCED BLOWER AND

More information

Defining Innovation. backward curved FANs

Defining Innovation. backward curved FANs Defining Innovation. high efficiency industrial backward curved FANs TYPE HIB BULLETIN 00-B May 20 HIB High-Efficiency Industrial Backward-Curved Fans Model HIB fans from Twin City Fan & Blower employ

More information

Liberec,

Liberec, POWER GYROSCOPES OF STABILIZING SYSTEM Šimek, J. 1 - Šklíba, J. 2 - Sivčák, M. 2 Škoda, J. 2 Abstract: The paper deals with problems concerning power gyroscopes for stabilization of vibro-izolation system.

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

CASE STUDY ANALYSIS OF PROCESS FAN FAILURE AND BEARING HOUSING/SHAFT DESIGN. Ken Singleton

CASE STUDY ANALYSIS OF PROCESS FAN FAILURE AND BEARING HOUSING/SHAFT DESIGN. Ken Singleton CASE STDY ANALYSIS OF PROCESS FAN FAILRE AND BEARING HOSING/SHAFT DESIGN Ken Singleton Manager KSC Consulting LLC, Bristol VA ksingleton@vibrationconsulting.com Alan Barbee Reliability Engineer Fortron

More information

A Recommended Approach to Pipe Stress Analysis to Avoid Compressor Piping Integrity Risk

A Recommended Approach to Pipe Stress Analysis to Avoid Compressor Piping Integrity Risk A Recommended Approach to Pipe Stress Analysis to Avoid Compressor Piping Integrity Risk by: Kelly Eberle, P.Eng. Beta Machinery Analysis Calgary, AB Canada keberle@betamachinery.com keywords: reciprocating

More information

PROFILING OF PULSATION AND VIBRATION IN COMPLEX RECIPROCATING COMPRESSOR FACILITIES

PROFILING OF PULSATION AND VIBRATION IN COMPLEX RECIPROCATING COMPRESSOR FACILITIES PROFILING OF PULSATION AND VIBRATION IN COMPLEX RECIPROCATING COMPRESSOR FACILITIES Bryan Fofonoff, P.Eng. Beta Machinery Analysis Ltd., 300, 1615 10 th Ave. SW., Calgary, AB, Canada, T3C 0J7 ABSTRACT

More information

Artesis MCM Case Studies. March 2011

Artesis MCM Case Studies. March 2011 Artesis MCM Case Studies March 2011 Case 1 Automotive Company: Automobile Manufacturer A Equipment: Pump Stator Isolation Breakdown Decreasing current unbalance level Case 1 Automotive Company: Automobile

More information

Machinery Vibration Limits and Dynamic Structural Response

Machinery Vibration Limits and Dynamic Structural Response E:\Marketing Communications\Papers and Presentations\Technical Papers\New Technical Papers\Machinery Vibration Limits#8.doc 1 Machinery Vibration Limits and Dynamic Structural Response By Brian C. Howes,

More information

Model 550 Series Vibration Switches

Model 550 Series Vibration Switches OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...

More information

ANTI-BACKLASH GEAR TRAIN INVESTIGATION. Zengxin Gao, Jani Tähtinen

ANTI-BACKLASH GEAR TRAIN INVESTIGATION. Zengxin Gao, Jani Tähtinen Zengxin Gao, Jani Tähtinen Wärtsilä Finland Oy Järvikatu 2-4, P.O. Box 244 FI-65101 Vaasa zengxin.gao@wartsila.com jani.tahtinen@wartsila.com 1 INTRODUCTION This paper is a continuation of study on Wärtsilä

More information

Damping Loss Factor for Damping Materials for Continuous Structures

Damping Loss Factor for Damping Materials for Continuous Structures Damping Loss Factor for Damping Materials for Continuous Structures P. H. Mathuria and U. P. Kulkarni mathuria@usa.net unmeshkulkarni@mailcity.com ABSTRACT The half power bandwidth method is used for measuring

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen is an

More information

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined

More information

DYNAMIC ABSORBERS FOR SOLVING RESONANCE PROBLEMS

DYNAMIC ABSORBERS FOR SOLVING RESONANCE PROBLEMS DYNAMIC ABSORBERS FOR SOLVING RESONANCE PROBLEMS Randy Fox Senior Staff Instructor Entek IRD International Corp. Houston, TX ABSTRACT Many experts in vibration analysis will agree that resonance is one

More information

Vibration studies and on-site balancing of GT-1 assembly

Vibration studies and on-site balancing of GT-1 assembly Page 1 of 32 Fig-1 showing the bump test measurements made on exciter rear end. A predominant frequency at 220 Hz was seen in the spectrum Page 2 of 32 Fig-2 showing bump test measurements made on generator

More information

R35 GTR VR38 ALPHA DAMPER

R35 GTR VR38 ALPHA DAMPER R35 GTR VR38 ALPHA DAMPER a single piece damper moving the overhung weight of the rubber absorber behind and inside the OEM sized belt ribs. The Fluidampr design is approximately 9.75lbs., The OEM part

More information

Cyclone Custom Centrifugal Fans

Cyclone Custom Centrifugal Fans Cyclone Custom Centrifugal Fans A L P H A I R Custom Engineered Centrifugal Fans ALPHAIR s line of custom engineered centrifugal fans is ideally suited for applications that involve moving air at higher

More information

Reciprocating Compressor Installation and Validation

Reciprocating Compressor Installation and Validation Reciprocating Compressor Installation and Validation MSD II - 11452 John Blamer (ME) Team Leader Promit Bagchi (ME) Lead Engineer Elliot Kendall (ME) Hydronics Engineer Matthias Purvis (ME) Operations

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY U.P.B. Sci. Bull., Series D, Vol. 77, Iss. 3, 2015 ISSN 1454-2358 TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY Claudiu BISU 1, Florian ISTRATE 2, Marin ANICA 3 Vibration

More information

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SM / SMI Heavy Duty, Axial Split Casing, Multi-Stage, Between Bearings, Horizontal Centrifugal Pipeline Pump, API 610 latest Edition SM / SMI For more

More information

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 2

11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part 2 11 Problems 11 Solutions Case Histories of 11 Machinery Vibration Problems Part Kevin R. Guy, Delaware Analysis Services, Inc., Francisco, Indiana This two-part article covers a series of eleven machinery

More information

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD. END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 50HZ OR 60HZ PA SERIES APPLICATIONS PA Series pumps can be used for the following services in commercial, residential, agriculture, industrial,

More information

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery Machine Protection Condition Monitoring Performance Analysis Economic Evaluation WINDROCK 6400: BENEFITS OF MACHINERY

More information

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS CLASSIFICATION OF ROLLING-ELEMENT BEARINGS Ball bearings can operate at higher speed in comparison to roller bearings because they have lower friction. In particular, the balls have less viscous resistance

More information

AIRCRAFT FINISHING Assembling the Front Seat Frames

AIRCRAFT FINISHING Assembling the Front Seat Frames AIRCRAFT FINISHING Assembling the Front Seat Frames Front Seat (shown with custom leather upholstery) The front seat frame assembly is supplied without upholstery. The seat back is hinged at the bottom

More information

Vibration Fundamentals Training System Hands-On Turnkey System for Teaching Vibration Fundamentals

Vibration Fundamentals Training System Hands-On Turnkey System for Teaching Vibration Fundamentals Vibration Fundamentals Training System Hands-On Turnkey System for Teaching Vibration Fundamentals www.haopute.com email:info@haopute.com phone:02884625157 mobile:18982185717 An Ideal Tool for Optimizing

More information

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery

WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery WINDROCK 6400 PORTABLE ANALYZER Premium Portable Monitoring for Reciprocating Machinery Machine Protection Condition Monitoring Performance Analysis Economic Evaluation WINDROCK 6400: BENEFITS OF MACHINERY

More information

MC High Pressure Stage Casing Pump

MC High Pressure Stage Casing Pump MC High Pressure Stage Casing Pump Sulzer Pumps Sulzer Pumps is a leading global supplier of reliable products and innovative pumping solutions for end users. Our active research and development, detailed

More information

Vibration product training Gearbox tutorial

Vibration product training Gearbox tutorial Vibration product training May 2012 Introduction Transducers come in two basic types Contact - which measure the absolute movement of the casing Noncontact - which measure the relative movement of the

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

Testing and validation of powder metal gears in a 6 speed manual transmission

Testing and validation of powder metal gears in a 6 speed manual transmission Testing and validation of powder metal gears in a 6 speed manual transmission Anders Flodin anders.flodin@hoganas.com Höganäs AB, Sweden Abstract A 6 speed manual transmission was redesigned and optimized

More information

OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT

OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT Brian Howes Beta Machinery Analysis, Calgary, AB, Canada, T3C 0J7 ABSTRACT This paper discusses several small issues that have occurred in the last

More information

ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING

ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING R. Subbiah Siemens Energy, Inc., 4400 Alafaya trail, Orlando FL 32817 USA Abstract An approach that enables rotor dynamists

More information

TEST METHODS CONCERNING TRANSPORT EQUIPMENT

TEST METHODS CONCERNING TRANSPORT EQUIPMENT PART IV TEST METHODS CONCERNING TRANSPORT EQUIPMENT - 403 - CONTENTS OF PART IV Section Page 40. INTRODUCTION TO PART IV... 407 40.1 PURPOSE... 407 40.2 SCOPE... 407 41. DYNAMIC LONGITUDINAL IMPACT TEST

More information

MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION

MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION Technical Paper MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION Tapered Double Inner Row Bearing Vs. Spherical Roller Bearing On The Fixed Position Laurentiu Ionescu,

More information

SEMITOP2,3,4 Press-Fit

SEMITOP2,3,4 Press-Fit Mounting Instruction SEMITOP2,3,4 Press-Fit Revision: 03 Issue date: 2017-08-28 Prepared by: Roberto Agostini Approved by: Werner Obermaier Keyword: SEMITOP, mounting instructions, one screw mounting,

More information

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS ZEPHYR CABINET Single & Twin Unit Cabinet Fans Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings, Features & Benefits 3 Options & Accessories 4 Typical Applications & Belt Drive

More information

Air Oil Lubrication Bearings with Re-lubricating Hole on the Outer Ring for Machine Tool

Air Oil Lubrication Bearings with Re-lubricating Hole on the Outer Ring for Machine Tool New Product Air Oil Lubrication Bearings with Re-lubricating Hole on the Outer Ring for Machine Tool Futoshi KOSUGI Kouji NISHINO The best design specification was established for angular contact ball

More information

Hydro Stator End Winding Accelerometer System

Hydro Stator End Winding Accelerometer System Hydro Stator End Winding Accelerometer System Bently Nevada Asset Condition Monitoring Description The hydro Stator End Winding Accelerometer (SEW Accel) system provides a cost effective and reliable method

More information

MODEL 205 ce VIBRATION METER

MODEL 205 ce VIBRATION METER OPERATION MANUAL VIBRATION METER (INCLUDES MODEL 205M ce) Page 2 TABLE OF CONTENTS SECTION TITLE PAGE 1. INTRODUCTION 3 Description 3 2. FEATURES 4 Batteries 4 Controls 4 Vibration Pickup 4 3. OPERATION

More information

Sulastic Rubber Springs

Sulastic Rubber Springs Sulastic Rubber Springs 2007 Toyota Tundra Sulastic Isolator Evaluation October 13, 2007 SPECTRUM Technologies, Inc. 12245 Wormer, Redford, MI 48239 Phone: 313-387-3000, Fax: 313-387-3095 Engineering Report

More information

Chapter 4. Vehicle Testing

Chapter 4. Vehicle Testing Chapter 4 Vehicle Testing The purpose of this chapter is to describe the field testing of the controllable dampers on a Volvo VN heavy truck. The first part of this chapter describes the test vehicle used

More information

Comparison of initial accumulator design using analytical and numerical methods

Comparison of initial accumulator design using analytical and numerical methods Pumps + Systems Compressors, Compressed Air and Vacuum Technology 3 rd International Rotating Equipment Conference (IREC) Pumps, Compressors and Vacuum Technology Düsseldorf, 14 15 September 2016 Comparison

More information

Bearings. Rolling-contact Bearings

Bearings. Rolling-contact Bearings Bearings A bearing is a mechanical element that limits relative motion to only the desired motion and at the same time it reduces the frictional resistance to the desired motion. Depending on the design

More information

Crude Oil Pump Internals

Crude Oil Pump Internals PLACE FOR TITLE Solving an Acoustic Resonance in AUTHORS Crude Oil Pump Internals Southwest Research Institute : Francisco Fierro, Research Engineer Sarah Simons, Research Scientist Speaker Biographies

More information

Industrial Mini Vent Sets

Industrial Mini Vent Sets Industrial Mini Vent Sets FRP Construction M I N I S E R I E S and Impellers Volume Range shut off up to 4000 (1888 l/sec) Static pressures up to 19 W.G. (4719 Pa) Industrial and Commercial Applications

More information

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE William F. Eckert, P.Eng., Ph.D. Field Services Manager Brian C. Howes, M.Sc., P.Eng. Chief Engineer Beta Machinery Analysis Ltd., Calgary, AB, Canada,

More information

Alan R. Klembczyk, Chief Engineer Taylor Devices, Inc. North Tonawanda, NY

Alan R. Klembczyk, Chief Engineer Taylor Devices, Inc. North Tonawanda, NY SIMULATION, DEVELOPMENT, AND FIELD MEASUREMENT VALIDATION OF AN ISOLATION SYSTEM FOR A NEW ELECTRONICS CABINET IN THE SPACE SHUTTLE LAUNCH ENVIRONMENT WITHIN THE MOBILE LAUNCH PLATFORM Alan R. Klembczyk,

More information

Waterfall Pumps Manufacturing

Waterfall Pumps Manufacturing Waterfall Pumps Manufacturing Our Vision for the future to become the world s premier provider of fire protection pumps. Our ongoing mission is to be the customers first choice, a trusted provider and

More information

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone:

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone: OEM and Industrial Air Handling Specialist SERIES CPAF CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN For more than 60 years the name Ruhrpumpen has been synonymous worldwide with innovation and reliability for pumping technology Ruhrpumpen is an

More information

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: HDBI BLOWERS OEM and Industrial Air Handling Specialist BACKWARD INCLINED CLASS II CLASS III CLASS IV 797 Snider Road, Mason, OH 45040-915 Telephone: 51-57-000 Visit us at www.cincinnatifan.com for more

More information

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio Vaneaxial Fans Series 25 Series 53 Series 53C Series 54 Series 55 BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 February 2008 Index Model Code Explanation...Page

More information

FAILURE ANALYSIS & REDESIGN OF A BRAKE CALLIPER SUPPORT. Prof. A. Bracciali, Dr. F. Piccioli, T. De Cicco

FAILURE ANALYSIS & REDESIGN OF A BRAKE CALLIPER SUPPORT. Prof. A. Bracciali, Dr. F. Piccioli, T. De Cicco FAILURE ANALYSIS & REDESIGN OF A BRAKE CALLIPER SUPPORT Prof. A. Bracciali, Dr. F. Piccioli, T. De Cicco Dipartimento di Meccanica e Tecnologie Industriali Università di Firenze, via Santa Marta 3, 50139

More information

Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure

Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure Journal of Engineering and Technology of the Open University of Sri Lanka (JET-OUSL), Vol. 4, No.1, 2016 Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure N.C Tantrigoda

More information

Static and Dynamic Calibration of a Triaxial Force Gage for Monitoring the Structureborne Forces Within a Freon Compressor

Static and Dynamic Calibration of a Triaxial Force Gage for Monitoring the Structureborne Forces Within a Freon Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 1992 Static and Dynamic Calibration of a Triaxial Force Gage for Monitoring the Structureborne

More information

TITLE: EVALUATING SHEAR FORCES ALONG HIGHWAY BRIDGES DUE TO TRUCKS, USING INFLUENCE LINES

TITLE: EVALUATING SHEAR FORCES ALONG HIGHWAY BRIDGES DUE TO TRUCKS, USING INFLUENCE LINES EGS 2310 Engineering Analysis Statics Mock Term Project Report TITLE: EVALUATING SHEAR FORCES ALONG HIGHWAY RIDGES DUE TO TRUCKS, USING INFLUENCE LINES y Kwabena Ofosu Introduction The impact of trucks

More information

Noise Emissions At the Chicago Fuller Car Wash

Noise Emissions At the Chicago Fuller Car Wash Specialists in Hearing and Acoustics 12172 Route 47 - #218, Huntley, Illinois 60142 Tom Thunder, AuD, FAAA, INCE Principal Office: 847-359-1068 Fax: 847-359-1207 Greg Andorka, BSEE - Senior Field Engineer

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA MODELING SUSPENSION DAMPER MODULES USING LS-DYNA Jason J. Tao Delphi Automotive Systems Energy & Chassis Systems Division 435 Cincinnati Street Dayton, OH 4548 Telephone: (937) 455-6298 E-mail: Jason.J.Tao@Delphiauto.com

More information

IVTM Installation Manual

IVTM Installation Manual Integrated Vehicle Tire Pressure Monitoring IVTM Installation Manual 2nd edition Copyright WABCO 2006 Vehicle Control Systems An American Standard Company The right of amendment is reserved Version 002/06.06(us)

More information

AGN 076 Alternator Bearings

AGN 076 Alternator Bearings Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 076 Alternator Bearings BEARING TYPES In the design of STAMFORD and AvK alternators, the expected types of rotor

More information

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps 1.0 Purpose A. The following guidelines apply to the selection of pumps primarily for circulating water. It is the goal of NC State to purchase pumps that are selected to provide a long service life, minimal

More information

ME scope Application Note 29 FEA Model Updating of an Aluminum Plate

ME scope Application Note 29 FEA Model Updating of an Aluminum Plate ME scope Application Note 29 FEA Model Updating of an Aluminum Plate NOTE: You must have a package with the VES-4500 Multi-Reference Modal Analysis and VES-8000 FEA Model Updating options enabled to reproduce

More information

Chapter 11. Keys, Couplings and Seals. Keys. Parallel Keys

Chapter 11. Keys, Couplings and Seals. Keys. Parallel Keys Chapter 11 Keys, Couplings and Seals Material taken for Keys A key is a machinery component that provides a torque transmitting link between two power-transmitting elements. The most common types of keys

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

Static and Dynamic Strength Analysis on Rear Axle of Small Payload Off-highway Dump Trucks

Static and Dynamic Strength Analysis on Rear Axle of Small Payload Off-highway Dump Trucks Static and Dynamic Strength Analysis on Rear Axle of Small Payload Off-highway Dump Trucks Ji-xin Wang, Guo-qiang Wang, Shi-kui Luo, Dec-heng Zhou College of Mechanical Science and Engineering, Jilin University,

More information

CHAPTER 5 PARAMETRIC STUDIES AND SQUEAL REDUCTION METHODS

CHAPTER 5 PARAMETRIC STUDIES AND SQUEAL REDUCTION METHODS 17 CHAPTER 5 PARAMETRIC STUDIES AND SQUEAL REDUCTION METHODS 5.1 INTRODUCTION Generally, there are a number of methods that have been used in order to reduce squeal for the improvement of passengers comfort.

More information

Chapter 11 Rolling Contact Bearings

Chapter 11 Rolling Contact Bearings Chapter 11 Rolling Contact Bearings 1 2 Chapter Outline Bearing Types Bearing Life Bearing Load Life at Rated Reliability Bearing Survival: Reliability versus Life Relating Load, Life, and Reliability

More information

Boiler Feed Booster Pump YNK. Type Series Booklet

Boiler Feed Booster Pump YNK. Type Series Booklet YNK Type Series Booklet Legal information/copyright Type Series Booklet YNK All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

QMOT STEPPER MOTORS MOTORS

QMOT STEPPER MOTORS MOTORS QMOT STEPPER MOTORS MOTORS V 1.08 QMOT QSH6018 MANUAL + + QSH-6018-45-28-110 60mm 2.8A, 1.10 Nm -56-28-165 60mm 2.8A, 1.65 Nm -65-28-210 60mm 2.8A, 2.10 Nm + + -86-28-310 60mm 2.8A, 3.10 Nm TRINAMIC Motion

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF   CATALOG 950 AUGUST 2012 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012 RADIAL TIP FANS Model RTF Model RTF radial tip fans are of a heavy duty, rugged design,

More information

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009 Defining Innovation. radial tip FANS TYPE HRT BULLETIN 980 October 2009 HRT Radial Tip Fans Twin City Fan & Blower s Type HRT Industrial Duty Radial Tip Fan line is engineered for higher specific speeds.

More information

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers U. Bin-Nun FLIR Systems Inc. Boston, MA 01862 ABSTRACT Cryocooler self induced vibration is a major consideration in the design of IR

More information

Torsional Analysis Challenges of a Centrifugal Pump Train. Niels Peter Pauli Lloyd s Register Consulting Niklas Sehlstedt Lloyd s Register Consulting

Torsional Analysis Challenges of a Centrifugal Pump Train. Niels Peter Pauli Lloyd s Register Consulting Niklas Sehlstedt Lloyd s Register Consulting Torsional Analysis Challenges of a Centrifugal Pump Train Niels Peter Pauli Lloyd s Register Consulting Niklas Sehlstedt Lloyd s Register Consulting Presenter bios Niels Peter Pauli, M.Sc. Consultant,

More information

CONTENTS. DODGE Plummer Blocks

CONTENTS. DODGE Plummer Blocks CONTENTS DODGE Plummer Blocks Features/Benefits.......................................... B12-2 How To Order............................................. B12-4 Nomenclature.............................................

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery DATA & FACTS Unit Heaters MultiMAXX HB Quick Selection and Fast Delivery Table of Contents MultiMAXX HB Unit Type Code... 3 About this Catalogue... 4 Overview of Capacity... 5 Unit Description... 6 Unit

More information

CHAPTER 4: EXPERIMENTAL WORK 4-1

CHAPTER 4: EXPERIMENTAL WORK 4-1 CHAPTER 4: EXPERIMENTAL WORK 4-1 EXPERIMENTAL WORK 4.1 Preamble 4-2 4.2 Test setup 4-2 4.2.1 Experimental setup 4-2 4.2.2 Instrumentation, control and data acquisition 4-4 4.3 Hydro-pneumatic spring characterisation

More information

Prototyping of Radial and Thrust Air Bearing for Micro Gas Turbine

Prototyping of Radial and Thrust Air Bearing for Micro Gas Turbine Proceedings of the International Gas Turbine Congress 2003 Tokyo November 2-7, 2003 DRAFT IGTC2003Tokyo TS-019 Prototyping of Radial and Thrust Air Bearing for Micro Gas Turbine Susumu KITAZAWA, Shigehiko

More information