FHSCP-UNV-10P-L-SD SPECIFICATIONS

Size: px
Start display at page:

Download "FHSCP-UNV-10P-L-SD SPECIFICATIONS"

Transcription

1 SPECIFICATIONS Emergency LED Driver Universal Voltage: VAC, 50/60Hz Output Wattage: 1-10W Output Current: 620mA Max. Long Case and Terminal Output voltage range of 16-55VDC This Driver Will Operate The Following LED Modules: Any LED module designed to accept input voltage range of 16-55VDC and can operate up to current of 620mA. General Specifications Input Voltage Input Current Input Power Standby Input Power Driver Type Output Current Output Voltage Range Output Power Number of Output Channels RFI/EMI Output Type Battery Type Battery Capacity Available Battery Recharge Time Battery Discharge Time Ambient Operating Temperature Range Sound Rating Input Surge Protection Protections Service Life Approvals / Class VAC, 50/60Hz 0.06A Max. 6W <0.5W Constant Power 620mA Max VDC 1-10W 3000mA Battery, 1800mA Battery, 1500mA Battery) 1 Channel FCC Part 15A Non-Consumer Class 2 9.6VDC 3000mAh, 1800mAh, 1500mAh 12 Hours (Refer To Battery chart) 90 Minutes Min. 10 C to 55 C (50 F to 131 F) A Line-Neutral 2kV, Line & Neutral-Ground 2kV Over / Under Voltage Protection Output Open Circuit Protection Overload Protection 50,000 hours RoHS,, CEC Title 20 Mechanical Data Tolerance=±0.02" Page1of8

2 GENERAL INSTALLATION GUIDELINES FOR LED EMERGENCY DRIVER IMPORTANT SAFE PRACTICES When using electrical equipment and this lighting device basic safety precaution should be followed at all times including but not limited to the following: PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY IMPORTANT: Do not connect battery until fixture is installed. IMPORTANT: An un-switched AC power source of 100VAC to 277VAC is required. This device is designed for use in fixtures listed for dry and damp locations. CAUTION: Make sure all electrical connections conform to the National Electrical Code and all applicable local regulations. CAUTION: Do not let power supply cords touch hot surfaces. CAUTION: Do not mount near gas or electric heaters. CAUTION: Do not use outdoors. CAUTION: Battery is rechargeable type and must be recycled or disposed of properly. Do not use this emergency driver with accessory equipment other than recommended by manufacturer; failure to follow this may cause an unsafe condition. Servicing should only be performed by qualified service personnel. Do not use this emergency driver for other than intended use. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. IMPORTANT: Indicator (LED light) illuminated indicates battery in charge mode when AC power is applied. It is recommended and required by applicable code to test emergency function to ensure proper operation of the system; push the test switch for thirty (30) seconds every 30 days to ensure the emergency driver is functioning as LED light source illuminated. Conduct a ninety minute (90) discharge test one time (1) per year; LED light source should be illuminated for a minimum of ninety minutes (90). ASSEMBLY and FIELD INSTALLATION WIRING: WARNING: AC power must be off before proceeding with assembly or installation of emergency driver. TESTING SYSTEM: The emergency battery requires a charge minimum of one (1) hour before testing the circuit. A full charge requires twelve (12) hours. Fulham Head Quarters: Fulham Co., Inc South Van Ness Ave. Hawthorne, CA Manufacturer: North China Fulham Electronic Co. Ltd. No. 9 Xingchang Road, Nanshao Zhen Changping Science Park, Beijing, P.R. China SAVE THESE INSTRUCTIONS Page2of8

3 SELF DIAGNOSTIC INSTRUCTIONS / OPERATION: The self diagnostic feature is factory enabled. The emergency LED driver will conduct a self check for thirty (30) minutes every thirty (30) days and ninety (90) minutes every 12 months. After every self check the LED indicator light will indicate a status signal. A single self-diagnostic test can be activated by pressing the test switch three (3) times. Refer to table 1 for details. The self diagnostic feature can be disabled by using the TPSB-100 SmartSet controller or by using the Smart Set software. The output emergency power is programmable up to 10W for a minimum of 90 minutes (refer to battery chart for information on max load ratings of batteries). TABLE 1 - Self Diagnostic Indications LED Indicator Description LED Indicator Status Signal Description of Status Signal Comment Permanent Green ON System OK AC mode Slow Flashing Green 1.0s ON and 1.0s OFF Self-Diagnostic test underway Flashing Red 4.0s ON and 1.0s OFF Battery not connected Connect the battery Slow Flashing Red 1.0s ON and 1.0s OFF Battery failure Change the battery Fast Flashing Red 0.1s ON and 0.1s OFF Charge circuit is broken Change the driver Green and Red Off OFF (With LED Load ON) DC mode Battery operation (emergency mode) Note: Can take up to one minute for status to be updated when issue is corrected. TPSB-100: For detail information on using TPSB-100 Driver Programming Box, please consult user s manual of TPSB-100. Page3of8

4 Wiring Diagrams 1 TEST TO LED Driver L N GND FHSCP-UNV-10P-L-SD PRG (-) PRG (+) LED (-) LED (+) To LED Driver Output (-) To LED Driver Output (+) BATTERY LINE WALL WHITE(COMMON) GND TO LED Driver BLACK WHITE LED DRIVER RED (+) BLUE (-) Driver Must Be Grounded + - NOTE: DRILL ½ (12.7mm) DIA. HOLE IN MOUNTING PLATE TO INSERT TEST + - LED (+) LED (-) TEST Page4of8

5 Wiring Diagrams 2 LINE WALL BLACK WHITE LED DRIVER RED (+) BLUE (-) Driver Must Be Grounded NOTE: DRILL ½ (12.7mm)DIA. HOLE IN MOUNTING PLATE TO INSERT TEST TEST Page5of8

6 Wiring Diagrams 3 TEST TO LED Driver L N GND FHSCP-UNV-10P-L-SD PRG (-) PRG (+) LED (-) LED (+) BATTERY LINE WALL WHITE(COMMON) GND TO LED Driver BLACK WHITE LED DRIVER RED (+) BLUE (-) Driver Must Be Grounded + - NOTE: DRILL ½ (12.7mm) DIA. HOLE IN MOUNTING PLATE TO INSERT TEST LED (+) LED (-) TEST Battery Chart Fulham Model No. Chemistry Compliant Pack Capacity Max Load for 90 min. Battery Voltage Recharge Time FHSBATL3-1.5-SD RoHS 1500mAh 5W 9.6V 12Hrs FHSBATL3-3-SD RoHS 3000mAh 10W 9.6V 12Hrs FHSBATL9-.6-SD RoHS 1800mAh 6W 9.6V 12Hrs FHSBATL6-1.5L-SD* RoHS 3000mAh 10W 9.6V 12Hrs CAUTION: Replace battery only with corresponding part number. * Note: These batteries do not include mounting means, separate mounting brackets are available. Page6of8

7 Battery Dimensions FHSBATL3-1.5-SD 5W, 1500mAh, 9.6V FHSBATL3-3-SD 10W, 3000mAh, 9.6V FHSBATL9-.6-SD 6W, 1800mAh, 9.6V Page7of8

8 Battery Dimensions FHSBATL6-1.5L-SD 10W, 3000mAh, 9.6V Mounting Bracket Dimensions (Optional) FHSBATSC6-1.5L Page8of8

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS Emergency LED Universal Voltage: 100-277VAC, 50/60Hz Output Wattage: 1-10W Output Current: 620mA Max. Long Case and Terminal Output voltage range of 16-55VDC This Will Operate The Following LED Modules:

More information

FHS2-UNV-36L INSTALLATION INSTRUCTIONS

FHS2-UNV-36L INSTALLATION INSTRUCTIONS Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage: 1.2-20W Output Current: 700mA Max. Output voltage range of 12-55VDC This Driver Will Operate The Following LED Modules: Any LED

More information

FHS2-UNV-56S SPECIFICATIONS

FHS2-UNV-56S SPECIFICATIONS SPECIFICATIONS MECHANICAL DATA NiCd/LiFePO4 E313578 Emergency LED Driver Universal Voltage: 100-277VAC, 50/60Hz Output Wattage range of 1.2-20W Output Current range of 100mA - 700mA Output voltage range

More information

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W. FHS2-UNV-56S SPECIFICATION SHEET: This Is An Original Product From Fulham Co., Inc Description: Emergency LED Driver For Back-up Lighting. This Driver Will Operate Constant Current LED Arrays With a Working

More information

Cat# DC LED Array Emergency Driver

Cat# DC LED Array Emergency Driver Cat# 72918 DC LED Array Emergency Driver Morris DC LED Array Emergency Driver provides emergency operation of DC LED arrays during loss of AC power. In the event of AC power failure, the 72918 will operate

More information

FHEZ10A24 FHEZ10A24 - CEC 24" EZ EXIT EM T-Grid

FHEZ10A24 FHEZ10A24 - CEC 24 EZ EXIT EM T-Grid - CEC 24" EZ EXIT EM T-Grid Universal mounting allows for installation with all types of T-Grid Universal Input 20-277VAC High Lumen Output EM Solution; Powered by FHSCP EM driver Integrated Test Switch

More information

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit

TRMUNV065EC8XXA TRAUNV065EC8XXA Universal Voltage LED Canopy Retrofit Kit Universal Voltage LED Canopy Retrofit Kit General Specifications Input Voltage Input Current Input Power Input PF THD Max Lumen Output @ Full Power Dimming Type/Range Beam Angle CRI Storage Temperature

More information

MODEL : FHS2-UNV-36L

MODEL : FHS2-UNV-36L Battery Chart Fulham Model No. Chemistry Pack Capacity Max Load for 90 min. Battery Voltage Recharge Time FHSBATT8-AA.9 NiCd 900mAh 4W 9.6V 24Hrs FHSBATT8-C3 NiCd 3000mAh 16W 9.6V 32Hrs FHSABATT8-D4 NiCd

More information

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: SURE-LITES Installation Instructions For FBP-1-40X IMPTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: 1. READ AND FOLLOW ALL

More information

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine

VKMUNV018RDxxxA. UNV DC Engines Retrofit Kits with 0-10V Dimming Universal Voltage (120~277) DC Engine UNV DC Engines Retrofit Kits with 0-0V Dimming Universal Voltage (20~277) DC Engine culus Classified 598C Suitable for open or fully enclosed luminaires culus Recognized 8750 Suitable for luminaires with

More information

SPECIFICATION SHEET : FHS2-UNV-36L

SPECIFICATION SHEET : FHS2-UNV-36L SPECIFICATION SHEET : FHS2-UNV-36L This Is An Original Product From Fulham Co., Inc Description : Emergency LED Driver For Back-up Lighting This driver will operate constant current LED arrays with a working

More information

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13. Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.7WL, 17WL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

More information

Installation and Operation Instructions 10/04/13

Installation and Operation Instructions 10/04/13 ELI-S-100 With DIMMING CAPABILITIES Installation and Operation Instructions eli series emergency lighting inverters NRTL/C! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS

More information

IMPORTANT SAFEGUARDS

IMPORTANT SAFEGUARDS INSTRUCTION MANUAL NON-INTERRUPTIBLE AC INVERTER SYSTEM MODEL EAC FTM 350 FOR EMERGENCY LIGHTING POWER IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed,

More information

Installation Instructions Central Battery Units

Installation Instructions Central Battery Units Phone: 605.542.4444 concealite.com! Installation Instructions s Please Save These Instructions Important Safeguards Read and Follow All Safety Instructions When using electrical equipment, basic safety

More information

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS Crystal Recessed Edge- lit LED Exit Signs Series CRRBB & CRRAC Battery Backup & AC Models 01.18.06 Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

More information

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following: INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY

More information

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following: INSTRUCTION MANUAL IMPORTANT SAFEGUARDS SERIES D LIGHTING EQUIPMENT When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY

More information

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination APPLICATION The BAL1400 fluorescent emergency ballast works in conjunction with the AC ballast to convert

More information

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES INSTALLATION, OPERATION & MAINTENANCE DATA SHEET (EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES) EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES CAUTION:

More information

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST APPLICATION The BALT5-800 low-profile fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures

More information

SURE-LITES FBP140XLP Instruction Manual

SURE-LITES FBP140XLP Instruction Manual SURELITES Instruction Manual IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION:

More information

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits

120VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits TKMUNV0HRXXX, TET200HRXXX, TKT200HRXXX, TEMUNV0HRXXX, TKMUNV0HRXXX, 20VAC / Universal Input Half Round LED DC Engines and LED DC Engine Retrofit Kits High Density, high brightness chip array Class 2 Lighting

More information

LED Driver Selection Guide

LED Driver Selection Guide LED Driver Selection Guide Fulham is the preferred partner of over 3000 lighting manufacturers and distributors worldwide. As a pioneer in the electronic lighting industry, we have the product breadth

More information

LED Driver Selection Guide

LED Driver Selection Guide LED Driver Selection Guide Fulham is the preferred partner of over 3000 lighting manufacturers and distributors worldwide. As a pioneer in the electronic lighting industry, we have the product breadth

More information

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits

120VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits TKMUNV0RDXXX TET200RDXXX, TKT200RDXXX, TEMUNV0RDXXX,TKMUNV0RDXXX, 20VAC / Universal Input Round LED DC Engines and LED DC Engine Retrofit Kits 7" diameter x 0.945 H RD: TM2RD05XX-2X TEM/TKM: 20g RD: TM40RD05XX-2X

More information

UL AND CODE COMPLIANCE

UL AND CODE COMPLIANCE BAL500 FLUORESCENT EMERGENCY BALLAST 500 Lumens APPLICATION The BAL500 fluorescent emergency ballast works in conjunction with the AC ballast to convert new or existing fluorescent fixtures into emergency

More information

Self-Testing Industrial Series

Self-Testing Industrial Series Series: AS-I (Maint.-Free) Self-Testing Industrial Series Emergency Lighting Equipment Instructions for INSTALLATION OPERATION SERVICE SPECIFICATIONS 1300650 1300654 1300666 1300754 1300823 1300886 Hubbell

More information

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack www.osram.us/optotronic OPTOTRONIC Programmable LED Emergency Driver and Battery Pack Dual mode programmable driver that supports normal and emergency mode The OSRAM OPTOTRONIC Emergency Driver family

More information

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: SERIES E Emergency Lighting Equipment IMPTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

More information

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT Service Questions Call: 910-259-1131 IMPORTANT SAFEGUARDS CLASS I DIV 2 HAZARDOUS LOCATION GROUPS A, B, C, AND D ZONE 2 GROUPS IIC, IIB AND IIA CLASS II DIV 2

More information

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination APPLICATION The BAL3000 fluorescent emergency ballast works in conjunction with an AC

More information

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable. FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all replacement lamp types marked on the installed luminaire

More information

Spectron Industrial Series

Spectron Industrial Series 1300650 1300654 1300666 1300754 1300823 1300886 Table B Constant Value per Voltage System Wire Size (Maximum Voltage Drop 5%) System 6 Volt 12 Volt 24 Volt Wire Size #12 #10 #8 #6 #12 #10 #8 #6 #10 #12

More information

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits

TJT120034ACxxxB TJT120034ACxxxC 120V LED DirectAC Engine and Retrofit Kits 0V LED DirectAC Engine and Retrofit Kits Suitable for open or fully enclosed luminaires Full CCT Option Available (Standard CCT s: 700K,3000K,4000K) Suitable for luminaires with plastic and glass lenses

More information

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits

TJT120015ACxxxB TJT120015ACxxxC 120V LED DirectAC Engine and Retrofit Kits 0V LED DirectAC Engine and Retrofit Kits Suitable for open or fully enclosed luminaires Full CCT Option Available (Standard CCT s: 700K,3000K,4000K) Suitable for luminaires with plastic and glass lenses

More information

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards 049-289 Sure-Lites Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. WARNING Risk of Fire/Electric Shock If not qualified, consult an electrician. WARNING Risk

More information

Emergency and Exit Solutions

Emergency and Exit Solutions Emergency and Exit Solutions Product Selection Guide Emergency Backup Fluorescent Emergency Ballasts Emergency Lights & Exit Signs A Pioneer in Lighting Electronics Fulham is dedicated to clever, sustainable

More information

LED Retrofit Kits Vol. 1

LED Retrofit Kits Vol. 1 LED Retrofit Kits 2018 Vol. 1 Table of Contents 3 New Products 4 DC LED Engine Retrofit Kits 6 DirectAC LED Retrofit Kits 8 Canopy LED Retrofit Kit 9 Highbay LED Retrofit Kit 10 HotSpot1 LED Emergency

More information

Emergency and Exit Solutions Product Selection Guide. LED Emergency Backup Fluorescent Emergency Ballasts Emergency Lights & Exit Signs

Emergency and Exit Solutions Product Selection Guide. LED Emergency Backup Fluorescent Emergency Ballasts Emergency Lights & Exit Signs Emergency and Exit Solutions Product Selection Guide LED Emergency Backup Fluorescent Emergency Ballasts Emergency Lights & Exit Signs A Pioneer In Lighting Electronics North America Manufacturing California

More information

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable. FLUORESCENT EMERGENCY BALLAST WARNING: When using this lighting device, safety precautions should be followed at all times. CAUTION: Verify that all repalcment lamp types marked on the installed luminaire

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS MILLENIUM METREX METEL SERIES INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS DO NOT USE OUTDOORS. DO NOT MOUNT NEAR GAS OR ELECTRIC HEATERS. 1 APPLICATIONS EQUIPMENT

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be followed

More information

Europe Featured Products Catalogue

Europe Featured Products Catalogue Europe Featured Products Catalogue 2017 Innovative Lighting Solutions LED Drivers, Modules, LED Emergency & More A Pioneer In Lighting Electronics North America Manufacturing California Global Headquarters

More information

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by: 1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps

More information

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:

More information

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com

More information

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector

Technical specification. POW12V20A-D1 Charger. LFP/LTO + BMS connector Technical specification POW12V20A-D1 Charger LFP/LTO + BMS connector 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage frequency 47-63

More information

EMIU 720W Mini Inverter

EMIU 720W Mini Inverter THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using

More information

Technical specification. POW48V10A-D1 Charger. LFP/LTO + BMS connector

Technical specification. POW48V10A-D1 Charger. LFP/LTO + BMS connector Technical specification POW48V10A-D1 Charger LFP/LTO + BMS connector LFP/LTO + BMS CNECTOR 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage

More information

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION To prevent electrical

More information

VR22-MU-xxx-8yy-xxxxA

VR22-MU-xxx-8yy-xxxxA 22 UNIVERSAL INPUT LINEAR LED RETROFIT KITS Suitable for 2 x 2 luminaires Suitable for use in retrofit rebate programs Kitted for ease of Installation with provided harness Universal Voltage with 0-0V

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

Technical specification. POW24V20A-D1 Charger. LFP/LTO + BMS connector

Technical specification. POW24V20A-D1 Charger. LFP/LTO + BMS connector Technical specification POW24V20A-D1 Charger LFP/LTO + BMS connector LFP/LTO + BMS CNECTOR 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage

More information

15W (+/- 1W) 5.08" diameter x 0.75 H. Energy Star Luminaire CSD

15W (+/- 1W) 5.08 diameter x 0.75 H. Energy Star Luminaire CSD DirectAC UNV Retrofit Kit Engines Integrated AC Direct Drive (No DC Driver) Universal Voltage (20~277) AC Engine Suitable for open or fully enclosed luminaires Suitable for luminaires with plastic and

More information

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com CONTENTS PRM-2 & PRM-3 1. Warranty...3

More information

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using

More information

TMU040005ELXXXA TMU040005ELXXXB

TMU040005ELXXXA TMU040005ELXXXB 50 ma CONSTANT CURRENT DC S, 1.5 LINEAR, 590 LUMENS AND 5 LINEAR, 620 LUMENS High Density, high brightness chip array for use in Class 2 Linear applications Constant current for maximum efficacy Onboard

More information

TMU040010ELXXXA TMU040010ELXXXB TMU040010ELXXXC

TMU040010ELXXXA TMU040010ELXXXB TMU040010ELXXXC 50 ma CONSTANT CURRENT DC S, 5, 11, AND 17 LINEAR, 120 LUMENS High Density, high brightness chip array for use in Class 2 Linear applications Constant current for maximum efficacy Onboard connector for

More information

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS THIS UNIT CONTAINS A RECHARGEABLE VALVE-REGULATED LEAD ACID BATTERY. PLEASE RECYCLE OR DISPOSE OF PROPERLY. IMPORTANT SAFEGUARDS INTERRUPTIBLE EMERGENCY LIGHTING UNIT INVERTER INSTRUCTION MANUAL When using

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

34W (+/- 1W) 9.55" diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise

34W (+/- 1W) 9.55 diameter x 0.81 H. 2.5kV Common and Differential mode (Per ES Ring Wave Test) Sound Rating / Noise DirectAC UNV Retrofit Kit Engines Integrated AC Direct Drive (No DC Driver) culus Classified 1598C Universal Voltage (10~77) AC Engine culus Recognized 8750 Suitable for open or fully enclosed luminaires

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature

23W (+/- 1W) Leading Edge (TRIAC) or Trailing Edge (ELV) /100% ~ 10% Beam Angle CRI Operating Temperature Range (Ta) Maximum Engine Case Temperature DirectAC UNV Retrofit Kit Engines Integrated AC Direct Drive (No DC Driver) Universal Voltage (20~277) AC Engine Suitable for open or fully enclosed luminaires Suitable for luminaires with plastic and

More information

FieldView External Charger. User Guide

FieldView External Charger. User Guide FieldView External Charger User Guide D14059.02 April 2007 IMPORTANT SAFETY INFORMATION READ BEFORE USE The following precautions must be observed when operating the external charger. To reduce the risk

More information

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual EXP-EMG-2L-LE6 Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual Congratulations on the purchase of your new Explosion Proof Bug Eye Emergency LED Exit Fixture. Please read these instructions

More information

VR44-MU-xxx-8yy-xxxxA

VR44-MU-xxx-8yy-xxxxA 44 UNIVERSAL INPUT LINEAR LED RETROFIT KITS Suitable for 2 x 4 luminaires Suitable for use in retrofit rebate programs Kitted for ease of Installation with provided harness Universal Voltage with 0-0V

More information

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE imagination at work GB User Manual Digital Energy Uninterruptible Power Supply

More information

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To

More information

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. - To

More information

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS

350 ma CONSTANT CURRENT LED DC MODULE, 17 LINEAR, 1845 LUMENS 350 ma CONSTANT CURRENT DC, 17 LINEAR, 1845 LUMENS High Density, high brightness chip array for use in Class 2 Linear applications Available in standard CCT's Dimmable when used with a dimmable driver

More information

LED. High-performance streetlight. -afortable and reliable

LED. High-performance streetlight. -afortable and reliable LED High-performance streetlight -afortable and reliable DESIGNED FOR FUNCTIONAL LIGHTING OF OUTDOOR ROADS WHERE ENERGY SAVING, LOW MAINTENANCE AND PRECISE LIGHT CONTROL CONSIDERATIONS ARE IMPORTANT FACTORS.

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

MIRRORLITE RECESSED EMERGENCY LIGHTING

MIRRORLITE RECESSED EMERGENCY LIGHTING 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. MIRRORLITE RECESSED EMERGENCY LIGHTING INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should

More information

V4 Cordless Lamp System User Guide

V4 Cordless Lamp System User Guide V4 Cordless Lamp System User Guide Contents Welcome Important Notes Components + Connection Diagram Charging Status Indicator Charging the Battery Lamp Control + Operating Modes Turning Function Operating

More information

Product Installation Document

Product Installation Document Honeywell 12 Clintonville Road Northford, CT 064721610 http://www.honeywellpower.com HP1205UL4, HP1205UL8, HP12010UL8, HP1210UL16 Power Supplies/Distribution Units PN 0618131: A 07/18/13 Product Installation

More information

Uninterruptible Power Supply

Uninterruptible Power Supply AC/DC Din Rail UPS System Single Phase Input, Single Phase Output Uninterruptible Power Supply 600VA UPS System AC/DC Din Rail Mount Line Interactive (PWM): 600VA User Manual M1201_Din_Rail_AC-DC_600VA_Manual

More information

Installation Instructions

Installation Instructions When using this lighting device the safety precautions should be followed at all times. PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS F YOUR OWN SAFETY 1. This device is designed for indoor use. Do

More information

POW72V35A/BMS CHARGER SPECIFICATION

POW72V35A/BMS CHARGER SPECIFICATION POW72V35A/BMS CHARGER SPECIFICATION 1. Input characteristics 1-1 Rated input voltage 230V Vac 1-2 Input voltage range 180V 264V Vac 1-3 AC input voltage 47-63 Hz frequency 1-4 Inrush current < 100 A A

More information

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control

62.6g / 0.13lbs. RoHS Compliant Dry and Damp Location IC Over Temperature Control DirectAC UNV Retrofit Kit Engines Integrated AC Direct Drive (No DC Driver) culus Classified 1598C Universal Voltage (120~277) AC Engine culus Recognized 8750 Suitable for open or fully enclosed luminaires

More information

Lithium Power Supply

Lithium Power Supply Lithium Power Supply User Manual LPS 1200W-60Ah LPS 1500W-100Ah LPS 2500W-100Ah Compact lithium battery based power supply - for easy acces to 230V and 12V energy, everywhere! V1.1 Safety Instructions

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W ova UAC (V-UAC-M) Modified Sine Wave 650W 800W 1000W ISTRUCTIOS IMPORTAT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: 1. READ

More information

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual c-go 12V/10A 12V/20A Power supply and battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Mounting and installation... 4 4. Operation... 5 5. Problem solving...

More information

MANUAL. Single charger

MANUAL. Single charger MANUAL Single charger HST-PR-2830 & HST-PR-2830USA for HS-Technik batteries HST-PR-18xx HST-PR-14xx issue date: November 2016 Table of contents Page 1. Basic information...3 1.1. Purpose of this document...3

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

Twelve Unit Rapid Charger

Twelve Unit Rapid Charger Twelve Unit Rapid Charger FOR RECHARGEABLE LMR BATTERIES User Manual Model TWC12M ENDURA TWC12M Table of Contents Topic Page Introduction 1 Important 2 Caution 2-3 Features 4-5 Replacing A Charging Pod

More information

SMP3CTX Series Power Supply/Charger

SMP3CTX Series Power Supply/Charger SMP3CTX Series Power Supply/Charger Installation Guide Models Include: SMP3CTX SMP3PMCTX SMP3PMCTXX - Single Output. SMP3PMP4 - Four (4) Fuse Protected Outputs. SMP3PMP8 - Eight (8) Fuse Protected Outputs.

More information

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A Manual EN Appendix Lynx Ion BMS 400A / 1000A 1. SAFETY INSTRUCTIONS 1.1 In general Please read the documentation supplied with this product first, so that you are familiar with the safety signs en directions

More information

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. [2013.

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd.   [2013. Installation Manual Integrated Prepaid Keypad Meters For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. www.hxgroup.cn [2013.3] Meter Installation Manual- HXE34-KP 2 / 15 Introduction

More information

Installation Instruction

Installation Instruction T F W 604.549.9379 604.549.9555 fluxwerx.com Installation Instruction DRIVER ENCLOSURE Ceiling Type Version Grid Battery Pack GRID MOUNT INSTALL OPTIONS OPTION 1: Standard Vertical Grid drivers can be

More information

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks Project Type Model # Remarks Description: Firehorse Emergency Ballast for use with or without AC ballast designed to add emergency lighting when main AC power is interrupted for minimum of 90 minutes at

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com

More information

AWZ 110. AWZ 13,8V/1A/7Ah/LM

AWZ 110. AWZ 13,8V/1A/7Ah/LM AWZ 110 v.1.3 AWZ 13,8V/1A/7Ah/LM Linear buffer power supply unit Grade 2. EN* Edition: 9 from 02.11.2017 Supercedes the edition: 8 from 23.01.2017 GREY POWER plus Features: EN50131-6 compliance, 1 2 grades

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

Mini-Roto TM Paddle Wheel Installation & Operation Manual

Mini-Roto TM Paddle Wheel Installation & Operation Manual IOM LMR8000 Rev. F Mini-Roto TM Paddle Wheel Installation & Operation Manual Mini-Roto TM Paddle Wheel Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... Inspection and Handling Disposal

More information

Operating Instructions

Operating Instructions DuroSite & SafeSite Area Light with Adapters Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury,

More information

MaxLite LED UTILITY WRAP FIXTURES

MaxLite LED UTILITY WRAP FIXTURES General Safety Information To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions

More information