(A.Z.KHAN) CHIEF MANAGER

Size: px
Start display at page:

Download "(A.Z.KHAN) CHIEF MANAGER"

Transcription

1 GRAMIN BANK OF ARYAVART HEAD OFFICE, A /46, VIJAYKHAND, GOMTINAGAR LUCKNOW (U.P.) 600 Phone No /76/88/90-98, Fax No Id rrb.com HO/A&S/VKS/ 348 DATE..04 TENDER NOTICE (ONLY EMPANELLED ELECTRIAL CONTRACTORS CAN APPLY) Quotation for electrical, data cabling, ups wiring earthing work, Solar wiring etc in new / renovated Branches Garmin Bank of Aryavart a leading Gramin Bank having 65 branches, Regional offices and Head office having its operation in Hardoi,Unnao, Lucknow, Barabanki,Faizabad, Kannauj, Farrukhabad, Mainpuri, Aligarh, Mathura, Hathras, Agra,Ferozabad, Etah and Kasganj districts invites competitive rates for electrical work, data cabling, ups wiring, earthing work and solar wiring ( wherever required) at the proposed/ existing furnished / renovated branches/offices and new branches proposed to be opened. Separate offices tenders are to be submitted for maximum 3 sets (consisting or 3 districts) of districts. There are 6 sets which are marked as Annexure I, II, III, IV, V & VI. S.NO. SET OF DISTRICTS TENDER FORM NUMBER Hardoi + Unnao Annexure - I Lucknow + Barabanki +Faizabad Annexure - II 3 Kannauj +Farrukhabad +Mainpuri Annexure III 4 Aligarh +Mathura +Hathras Annexure IV 5 Agra + Ferozabad Annexure V 6 Etah + Kasganj Annexure VI TERMS AND CONDITIONS Competitive rates are to be submitted in closed envelope for 3 sets only (any three sets Annexure I to Annexure VI) of District under following terms and conditions: - Firms having minimum experience of at least 5 years in electrical, data cabling, UPS wiring and earthing work etc are eligible to quote. Firms are required to have experience of working for minimum 3 years with commercial Banks / Gramin Banks and must be registered / approved contractor for electrical work. Rates quoted should be inclusive of all type of charges, expenses, and Taxes FOR within the districts for which the rates are given. 3 Quote your competitive rate on enclosed formats (Annexure I to Annexure VI) separately for each set (MAXIMUM 3) in 3 closed separate envelopes. 4 Incomplete and conditional quotation will be treated as cancelled. 5 If it is found that the material used is not same as mentioned in quotation then the bank has the right to reject the work and for this Bank will not make any payment as well as the said firm may be removed from the Bank s empanelled list. 6 If any type of change is required in electrical work it should be duly approved by the Chief Manager, administration and services department Head office and the Regional Manager of that Region where the branch is located. 7 If rates quoted are accepted to Bank then the electrical work is to be completed in given time, please note that if the work is not completed within stipulated time then the bank has the right to impose the penalty at the rate of 3.00% for every week delay. 8 Rates quoted will be valid upto Bank reserves the right to place the order for each branch separately as the furnishing work at the premises is completed. 9 Note that the measurement, quantity of different items are tentative and may increase or decrease as per the requirement of the bank. The normal variation may be upto 0% or even more. 0 After the allotted work is completed the Regional Manager and the Chief Manager of A&S department, Head office or any officer authorised by the Chief Manager may verify the work. Bank will not provide any advance against the work order. Bank will retain 5.00% cost of bill for 80 days while making the payment to cover the defect liability. 3 Note that before starting the electrical work, the material which is to be used should be duly certified by the Regional Manager or by any other officer deputed from the Head office / Regional office. 4 Quotation in a closed envelope (separate envelope for any 3 sets ) must reach at head office positively on or before All these envelopes should be placed in big a sealed envelope. These quotations will be opened on on 3.30 PM at Head office in presence of committee members. All empanelled firms (who quoted the rates) are requested to remain present at the time of opening of tenders. Please note that no separate invitation will be sent. 5 Note that merely quoting the lowest rate is not the eligibility, bank may allot the work to more than vendor and in this regard the bank has the full right to accept or reject the one and all tenders without any notice. 6. Note carefully that Bank shall be under no obligation to accept the lowest or any other offer received in response to this tender. Order will be placed keeping in view all the norms, features, quality, performance, services, brand name and certification etc. The decision of the Bank in this regard will be final and binding. 7 Firms have to submit their details as per enclosed Annexure X along with required photocopy of papers required for verifications. 8 There are 6 set of 5 districts as mentioned from Annexure I to Annexure VI.Every vendor will be restricted to forward / send tenders upto a maximum of 3 sets in 3 separate sealed envelopes. Submission of tender / quotation for more than 3 (any) will not be entertained. 9 All vendors are required to doubly check calculations, rates etc.in case of any arithmetical mistake, (mentioned amount in the column of total cost or actual amount) the lowest between these two will be considered. 0 L of each category will also be ascertained whereas TL- ( Total lowest ) for all the 5 jobs viz A,B,C,D & E ( Bundle) will also be ascertained to place the order.on the basis of TL-,Bank may place the order either for all the 5 jobs or may confined to 4/3// job out of 5 jobs. There are 5 different jobs e.g. (A) Electrical work & UPS wiring,(b) Voltage stabilizer for power voltage control, (C) Wiring for power supply by solar power pack, (D) Data cabling and (E) Earthing work mentioned on the Annexure I tovi.bank may place order for any of these jobs stated as (A),(B), (C),(D) or (E).There will be no compulsion on the Bank to place order for more than one job however there may be a combination of,3 or 4 jobs. There will a sole discretion of the Bank to allot stated work of one branch to different vendors. To clarify more it is mentioned that stabilizer may be purchased from a first vendor whereas earthling may be allotted to second vendor and wiring may be assigned to third vendor. The Annexure :- ( I to VI) tender forms are enclosed herewith. : - Format -X (A.Z.KHAN) CHIEF MANAGER

2 ANNEXURE I GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED BRANCHES / PROPOSED NEW BRANCHES FOR HARDOI & UNNAO DISTRICTS ( A) ELECTRICAL WORK AND UPS WIRING S.NO MATERIALS DETAILS WITH LABOUR CHARGES QUANTITY UNIT COST( Rs) TOTAL COST (a) (b) (c ) ( d ) ( c ) x ( d ) = ( e ) 3 Nos. 00 Amps Kit Kat set link type with neutral link Havells make with wooden board of size ft x ft.( one for Kit Kat and one for power meter) 0 No. Havells make 6 sqr mm armound 4core Cable ( from main power supply point to main meter) 5 mts 3 Havells make 0 sqr mm unarmound 4core Cable ( from supply point to main meter) 5 mtr 4 Havells make 0 sqr mm unarmound single core Cable ( from power power point to Generator ) 5 mts 5 Supply 4' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG 44EB) with fitting charges. 8 No. 6 Supply of angle holder for bulbs including cost of 5 Watt CFL of Crompton greaves. 7 Supply of Wall mounted Fan 400 mm High Flow Wave Crompton greaves make with 8 Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with 9 S/F of Fresh air/ exhaust fan " Transair make Crompton with 0No. 0 S/F of fresh air fan 50 mm Briskair Compton greaves make with 0 No. 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 0 No. 63 Amp SP change over for Incomer main Line and Generator Havells make 0 No 3 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 4 Way SPN D.B Box Double Door of Havells 0 No. 5 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet 6 6 Amp MCBs of Havells 7 40 Amp Isolator Double Pole with way MCB BOX of Havells. 0 No Amp MCB Double Pole with way MCB BOX of Havells. 0 No. 9 5 Amp Combined Switch & Socket (Gang Box) Anchor make 0 No. 0 6 Amp Plug Top, Anchor. 0 No. 6 Amp Plug Top, Anchor. 0 No. TOTAL XXXXXX *

3 (B) VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION REMARK STABLIZER VOLTAGE RANGE AVERAGE OF ( e) & ( f ) v V ( e ) + ( f ) / (a) ( b) ( c) ( d ) ( e ) ( f ) (g) 7.50 KVA Output Voltage = 0v+/- % per phase AUTO OF Max Temp rise = 45 degree C above ambient. QUALITY ISI Make (Mention Cooling = Air cooled Operation mode = Auto 0.00 KVA ISI Make Output Voltage = 0v+/- % per phase Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mod = Auto AUTO OF QUALITY (Mention 3 TOTAL XXXXX XXXXX * ( C ) WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES S.NO MATERIAL DETAIL WITH LABOUR CHARGES QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( c ) x ( d )=( e) Wiring from output supply from solar power pack to four CFL of 5 watts and four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm for face and.5 sq.mm for neutral of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line modem/switch etc. Wiring is to be done in casing.( Havells wire) 00 meter 3 Change over (Havells) for solar power supply and Grid power supply. 4 TOTAL XXXXXX * (D) DATA CABLING S.NO. DISCRIPTIONS MAKE QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( e ) ( d ) x ( e) =( f ) G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 installation charges. 3 Patch panel Cat 6 ( port), with installation charges. D Link / Digi link 4 Patch cord mts. D Link / Digi link 06 5 Patch cord mts. D Link / Digi link 06 6 Steel rack (9U) wall mounted with 4-point power DB, one Valrack/ Digi link fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 7 Casing 9/9 mm, inch, AKG ( ISI) 75 mts 8 Casing 9/9 mm,.5 inch, AKG ( ISI) 75 mts 9 Structuring of data cabling. 50 mts 0 LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. Fixing of lease line / V-SAT Line in with clamps. XXXXXX TOTAL XXXXXX *

4 (E) EARTHING WORK S.NO. PARTICULARS RATE Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 46 mm to 50 mm, CPRI & RDSO tested :987 with two bag compound, electrodes (wire to be in PVC pipe duly clamped with wall) inclusive of all expances (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. Cost of 0.00 mm copper wire of good quality TOTAL * Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract every block (each block consist of 7 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. * This amount will be considered for L and TL

5 ANNEXURE II GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED BRANCHES / PROPOSED NEW BRANCHES FOR LUCKNOW, BARABANKI AND FAIZABAD DISTRICTS (A) ELECTRICAL WORK AND UPS WIRING S.NO MATERIALS DETAILS WITH LABOUR CHARGES QUANTITY UNIT COST ( Rs) TOTAL COST (a) (b) (c ) ( d ) ( c ) x ( d ) = ( e ) 3 Nos. 00 Amps Kit Kat set link type with neutral link Havells make with wooden board of size ft x ft.( one for Kit Kat and one for power meter) 0 No. Havells make 6 sqr mm armound 4core Cable ( from main power supply point to main meter) 5 mts 3 Havells make 0 sqr mm unarmound 4core Cable ( from supply point to main meter) 5 mtr 4 Havells make 0 sqr mm unarmound single core Cable ( from power power point to Generator ) 5 mts 5 Supply 4' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG 44EB) with fitting charges. 8 No. 6 Supply of angle holder for bulbs including cost of 5 Watt CFL of Crompton greaves. 7 Supply of Wall mounted Fan 400 mm High Flow Wave Crompton greaves make with 8 Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with 9 S/F of Fresh air/ exhaust fan " Transair make Crompton with 0No. 0 S/F of fresh air fan 50 mm Briskair Compton greaves make with 0 No. 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 0 No. 63 Amp SP change over for Incomer main Line and Generator Havells make 0 No 3 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 4 Way SPN D.B Box Double Door of Havells 0 No. 5 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet 6 6 Amp MCBs of Havells 7 40 Amp Isolator Double Pole with way MCB BOX of Havells. 0 No Amp MCB Double Pole with way MCB BOX of Havells. 0 No. 9 5 Amp Combined Switch & Socket (Gang Box) Anchor make 0 No. 0 6 Amp Plug Top, Anchor. 0 No. 6 Amp Plug Top, Anchor. 0 No. TOTAL XXXXXX *

6 ( B ) VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION REMARK STABLIZER VOLTAGE RANGE AVERAGE OF ( e) & ( f ) v V ( e ) + ( f ) / (a) ( b) ( c) ( d ) ( e ) ( f ) ( g) 7.50 KVA Output Voltag = 0v+/- % per phase AUTO OF Max Temp rise = 45 degree C above ambient. QUALITY ISI Make (mention Cooling = Air cooled Operation mode = Auto 0.00 KVA ISI Make Output Voltage = 0v+/- % per phase Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mod = Auto AUTO OF QUALITY ( mention 3 TOTAL XXXXX XXXXX * ( C ) WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES S.NO MATERIAL DETAIL WITH LABOUR CHARGES QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( c ) x ( d )=( e) Wiring from output supply from solar power pack to four CFL of 5 watts and four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm for face and.5 sq.mm for neutral of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line modem/switch etc. Wiring is to be done in casing ( Havells make) 00 meter 3 Change over (Havells) for solar power supply and Grid power supply. 4 TOTAL XXXXXX * (D) DATA CABLING S.NO. DISCRIPTIONS MAKE QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( e ) ( d ) x ( e) =( f ) G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 installation charges. 3 Patch panel Cat 6 ( port), with installation charges. D Link / Digi link 4 Patch cord mts. D Link / Digi link 06 5 Patch cord mts. D Link / Digi link 06 6 Steel rack (9U) wall mounted with 4-point power DB, one Valrack/ Digi link fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 7 Casing 9/9 mm, inch, AKG ( ISI) 75 mts 8 Casing 9/9 mm,.5 inch, AKG ( ISI) 75 mts 9 Structuring of data cabling. 50 mts 0 LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. Fixing of lease line / V-SAT Line in with clamps. XXXXXX TOTAL XXXXXX *

7 (E) EARTHING WORK S.NO. PARTICULARS RATE Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 46 mm to 50 mm, CPRI & RDSO tested :987 with two bag compound, electrodes (wire to be in PVC pipe duly clamped with wall) inclusive of all expances (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. Cost of 0.00 mm copper wire of good quality. TOTAL * Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract every block (each block consist of 7 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. *This amount will be considered for L and TLI ANNEXURE III

8 GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED BRANCHES / PROPOSED NEW BRANCHES FOR KANNAUJ, FARRUKHABAD AND MAINPURI DISTRICTS ( A ) ELECTRICAL WORK AND UPS WIRING S.NO MATERIALS DETAILS WITH LABOUR CHARGES QUANTITY UNIT COST(Rs) TOTAL COST (a) (b) (c ) ( d ) ( c ) x ( d ) = ( e ) 3 Nos. 00 Amps Kit Kat set link type with neutral link Havells make with wooden board of size ft x ft.( one for Kit Kat and one for power meter) 0 No. Havells make 6 sqr mm armound 4core Cable ( from main power supply point to main meter) 5 mts 3 Havells make 0 sqr mm unarmound 4core Cable ( from supply point to main meter) 5 mtr 4 Havells make 0 sqr mm unarmound single core Cable ( from power power point to Generator ) 5 mts 5 Supply 4' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG 44EB) with fitting charges. 8 No. 6 Supply of angle holder for bulbs including cost of 5 Watt CFL of Crompton greaves. 7 Supply of Wall mounted Fan 400 mm High Flow Wave Crompton greaves make with 8 Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with 9 S/F of Fresh air/ exhaust fan " Transair make Crompton with 0No. 0 S/F of fresh air fan 50 mm Briskair Compton greaves make with 0 No. 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 0 No. 63 Amp SP change over for Incomer main Line and Generator Havells make 0 No 3 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 4 Way SPN D.B Box Double Door of Havells 0 No. 5 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet 6 6 Amp MCBs of Havells 7 40 Amp Isolator Double Pole with way MCB BOX of Havells. 0 No Amp MCB Double Pole with way MCB BOX of Havells. 0 No. 9 5 Amp Combined Switch & Socket (Gang Box) Anchor make 0 No. 0 6 Amp Plug Top, Anchor. 0 No. 6 Amp Plug Top, Anchor. 0 No. TOTAL XXXXXX (x) ( B ) VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION REMARK STABLIZER VOLTAGE AVERAGE OF ( e) & ( f )

9 RANGE v V ( e ) + ( f ) / (a) ( b) ( c) ( d ) ( e ) ( f ) (g) 7.50 KVA Output Voltag = 0v+/- % per phase AUTO OF Max Temp rise = 45 degree C above ambient. QUALITY ISI Make Cooling = Air cooled (mention Operation mode = Auto 0.00 KVA ISI Make Output Voltage = 0v+/- % per phase Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mod = Auto AUTO OF QUALITY (mention 3 TOTAL XXXXX XXXXX * ( C ) WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES S.NO MATERIAL DETAIL WITH LABOUR CHARGES QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( c ) x ( d )=( e) Wiring from output supply from solar power pack to four CFL of 5 watts and four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm for face and.5 sq.mm for neutral of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line modem/switch etc. Wiring is to be done in casing ( Havells make) 00 meter 3 Change over (Havells) for solar power supply and Grid power supply. 4 TOTAL XXXXXX * (D) DATA CABLING S.NO. DISCRIPTIONS MAKE QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( e ) ( d ) x ( e) =( f ) G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 installation charges. 3 Patch panel Cat 6 ( port), with installation charges. D Link / Digi link 4 Patch cord mts. D Link / Digi link 06 5 Patch cord mts. D Link / Digi link 06 6 Steel rack (9U) wall mounted with 4-point power DB, one Valrack/ Digi link fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 7 Casing 9/9 mm, inch, AKG ( ISI) 75 mts 8 Casing 9/9 mm,.5 inch, AKG ( ISI) 75 mts 9 Structuring of data cabling 50 mts 0 LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. Fixing of lease line / V-SAT Line in with clamps. XXXXXX TOTAL XXXXXX * (E) EARTHING WORK S.NO. PARTICULARS RATE

10 Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 46 mm to 50 mm, CPRI & RDSO tested :987 with two bag compound, electrodes (wire to be in PVC pipe duly clamped with wall) inclusive of all expances (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. Cost of 0.00 mm copper wire of good quality TOTAL * Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract every block (each block consist of 7 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. *This amount will be considered for L and TL ANNEXURE IV

11 GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED BRANCHES / PROPOSED NEW BRANCHES FOR ALIGARH,MATHURA AND HATHRAS DISTRICTS ( A ) ELECTRICAL WORK AND UPS WIRING S.NO MATERIALS DETAILS WITH LABOUR CHARGES QUANTITY UNIT COST( Rs) TOTAL COST (a) (b) (c ) ( d ) ( c ) x ( d ) = ( e ) 3 Nos. 00 Amps Kit Kat set link type with neutral link Havells make with wooden board of size ft x ft.( one for Kit Kat and one for power meter) 0 No. Havells make 6 sqr mm armound 4core Cable ( from main power supply point to main meter) 5 mts 3 Havells make 0 sqr mm unarmound 4core Cable ( from supply point to main meter) 5 mtr 4 Havells make 0 sqr mm unarmound single core Cable ( from power power point to Generator ) 5 mts 5 Supply 4' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG 44EB) with fitting charges. 8 No. 6 Supply of angle holder for bulbs including cost of 5 Watt CFL of Crompton greaves. 7 Supply of Wall mounted Fan 400 mm High Flow Wave Crompton greaves make with 8 Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with 9 S/F of Fresh air/ exhaust fan " Transair make Crompton with 0No. 0 S/F of fresh air fan 50 mm Briskair Compton greaves make with 0 No. 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 0 No. 63 Amp SP change over for Incomer main Line and Generator Havells make 0 No 3 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 4 Way SPN D.B Box Double Door of Havells 0 No. 5 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet 6 6 Amp MCBs of Havells 7 40 Amp Isolator Double Pole with way MCB BOX of Havells. 0 No Amp MCB Double Pole with way MCB BOX of Havells. 0 No. 9 5 Amp Combined Switch & Socket (Gang Box) Anchor make 0 No. 0 6 Amp Plug Top, Anchor. 0 No. 6 Amp Plug Top, Anchor. 0 No. TOTAL XXXXXX * ( B ) VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION REMARK STABLIZER VOLTAGE RANGE AVERAGE OF ( e) & ( f ) v V ( e ) + ( f ) /

12 (a) ( b) ( c) ( d ) ( e ) ( f ) (g) 7.50 KVA Output Voltag = 0v+/- % per phase AUTO OF Max Temp rise = 45 degree C above ambient. QUALITY ISI Make Cooling = Air cooled (mention Operation mode = Auto 0.00 KVA ISI Make Output Voltage = 0v+/- % per phase Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mod = Auto AUTO OF QUALITY ( mention 3 TOTAL XXXXX XXXXX * ( C ) WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES S.NO MATERIAL DETAIL WITH LABOUR CHARGES QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( c ) x ( d )=( e) Wiring from output supply from solar power pack to four CFL of 5 watts and four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm for face and.5 sq.mm for neutral of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line modem/switch etc. Wiring is to be done in casing (Havells wire) 00 meter 3 Change over (Havells) for solar power supply and Grid power supply. 4 TOTAL XXXXXX * (D) DATA CABLING S.NO. DISCRIPTIONS MAKE QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( e ) ( d ) x ( e) =( f ) G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 installation charges. 3 Patch panel Cat 6 ( port), with installation charges. D Link / Digi link 4 Patch cord mts. D Link / Digi link 06 5 Patch cord mts. D Link / Digi link 06 6 Steel rack (9U) wall mounted with 4-point power DB, one Valrack/ Digi link fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 7 Casing 9/9 mm, inch, AKG ( ISI) 75 mts 8 Casing 9/9 mm,.5 inch, AKG ( ISI) 75 mts 9 Structuring of data cabling 50 mts 0 LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. Fixing of lease line / V-SAT Line in with clamps. XXXXXX TOTAL XXXXXX * (E) EARTHING WORK S.NO. PARTICULARS RATE

13 Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 46 mm to 50 mm, CPRI & RDSO tested :987 with two bag compound, electrodes (wire to be in PVC pipe duly clamped with wall) inclusive of all expances (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. Cost of 0.00 mm copper wire of good quality. TOTAL * Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract every block (each block consist of 7 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. *This amount will be considered for LI and TL ANNEXURE V

14 GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED BRANCHES / PROPOSED NEW BRANCHES FOR AGRA AND FEROZABAD DISTRICTS ( A ) ELECTRICAL WORK AND UPS WIRING S.NO MATERIALS DETAILS WITH LABOUR CHARGES QUANTITY UNIT COST(Rs) TOTAL COST (a) (b) (c ) ( d ) ( c ) x ( d ) = ( e ) 3 Nos. 00 Amps Kit Kat set link type with neutral link Havells make with wooden board of size ft x ft.( one for Kit Kat and one for power meter) 0 No. Havells make 6 sqr mm armound 4core Cable ( from main power supply point to main meter) 5 mts 3 Havells make 0 sqr mm unarmound 4core Cable ( from supply point to main meter) 5 mtr 4 Havells make 0 sqr mm unarmound single core Cable ( from power power point to Generator ) 5 mts 5 Supply 4' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG 44EB) with fitting charges. 8 No. 6 Supply of angle holder for bulbs including cost of 5 Watt CFL of Crompton greaves. 7 Supply of Wall mounted Fan 400 mm High Flow Wave Crompton greaves make with 8 Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with 9 S/F of Fresh air/ exhaust fan " Transair make Crompton with 0No. 0 S/F of fresh air fan 50 mm Briskair Compton greaves make with 0 No. 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 0 No. 63 Amp SP change over for Incomer main Line and Generator Havells make 0 No 3 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 4 Way SPN D.B Box Double Door of Havells 0 No. 5 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet 6 6 Amp MCBs of Havells 7 40 Amp Isolator Double Pole with way MCB BOX of Havells. 0 No Amp MCB Double Pole with way MCB BOX of Havells. 0 No. 9 5 Amp Combined Switch & Socket (Gang Box) Anchor make 0 No. 0 6 Amp Plug Top, Anchor. 0 No. 6 Amp Plug Top, Anchor. 0 No. TOTAL XXXXXX * ( B ) VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION REMARK STABLIZER VOLTAGE RANGE AVERAGE OF ( e) & ( f ) v V ( e ) + ( f ) /

15 (a) ( b) ( c) ( d ) ( e ) ( f ) ( g) 7.50 KVA Output Voltag = 0v+/- % per phase AUTO OF Max Temp rise = 45 degree C above ambient. QUALITY ( mention ISI Make Cooling = Air cooled Operation mode = Auto 0.00 KVA ISI Make Output Voltage = 0v+/- % per phase Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mod = Auto AUTO OF QUALITY ( mention 3 TOTAL XXXXX XXXXX * ( C ) WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES S.NO MATERIAL DETAIL WITH LABOUR CHARGES QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( c ) x ( d )=( e) Wiring from output supply from solar power pack to four CFL of 5 watts and four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm for face and.5 sq.mm for neutral of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line modem/switch etc. Wiring is to be done in casing ( Havells make) 00 meter 3 Change over (Havells) for solar power supply and Grid power supply. 4 TOTAL XXXXXX ( X ) (D) DATA CABLING S.NO. DISCRIPTIONS MAKE QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( e ) ( d ) x ( e) =( f ) G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 installation charges. 3 Patch panel Cat 6 ( port), with installation charges. D Link / Digi link 4 Patch cord mts. D Link / Digi link 06 5 Patch cord mts. D Link / Digi link 06 6 Steel rack (9U) wall mounted with 4-point power DB, one Valrack/ Digi link fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 7 Casing 9/9 mm, inch, AKG ( ISI) 75 mts 8 Casing 9/9 mm,.5 inch, AKG ( ISI) 75 mts 9 Structuring of data cabling. 50 mts 0 LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. Fixing of lease line / V-SAT Line in with clamps. XXXXXX TOTAL XXXXXX * (E) EARTHING WORK S.NO. PARTICULARS RATE

16 Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 46 mm to 50 mm, CPRI & RDSO tested :987 with two bag compound, electrodes (wire to be in PVC pipe duly clamped with wall) inclusive of all expances (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. Cost of 0.00 mm copper wire of good quality. TOTAL * Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract every block (each block consist of 7 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. *This amount will be considering for L and TL ANNEXURE VI

17 GRAMIN BANK OF ARYAVART QUOTATION FOR DATA CABLING, UPS WIRING, EARTHING, ELECTRICAL WORK FOR PROPOSED NEWLY FURNISHED BRANCHES / PROPOSED NEW BRANCHES FOR ETAH AND KASGANJ DISTRICTS (A) ELECTRICAL WORK AND UPS WIRING S.NO MATERIALS DETAILS WITH LABOUR CHARGES QUANTITY UNIT COST (Rs ) TOTAL COST (a) (b) (c ) ( d ) ( c ) x ( d ) = ( e ) 3 Nos. 00 Amps Kit Kat set link type with neutral link Havells make with wooden board of size ft x ft.( one for Kit Kat and one for power meter) 0 No. Havells make 6 sqr mm armound 4core Cable ( from main power supply point to main meter) 5 mts 3 Havells make 0 sqr mm unarmound 4core Cable ( from supply point to main meter) 5 mtr 4 Havells make 0 sqr mm unarmound single core Cable ( from power power point to Generator ) 5 mts 5 Supply 4' Long Surface Electronic Tube light fitting *36w Crompton Greaves make planet model (DSG 44EB) with fitting charges. 8 No. 6 Supply of angle holder for bulbs including cost of 5 Watt CFL of Crompton greaves. 7 Supply of Wall mounted Fan 400 mm High Flow Wave Crompton greaves make with 8 Supply of ceiling Fan 00 mm Sweep Winger Crompton greaves make (white colour) with 9 S/F of Fresh air/ exhaust fan " Transair make Crompton with 0No. 0 S/F of fresh air fan 50 mm Briskair Compton greaves make with 0 No. 63 Amp TP Rotary Switch for UPS Incomer main Line Havells make 0 No. 63 Amp SP change over for Incomer main Line and Generator Havells make 0 No 3 Industrial Cable 00v(Coil).5 Sqr mm (P+N+E) with AKG make casing n Capping & laying UPS Wiring with Havells/Anchor 50 meter 4 Way SPN D.B Box Double Door of Havells 0 No. 5 5 Amp 3 No. Way Switch & 5 Amp 3 No. Socket, No. Indicator Anchor make with 8*0 good quality Wooden Box & Sheet 6 6 Amp MCBs of Havells 7 40 Amp Isolator Double Pole with way MCB BOX of Havells. 0 No Amp MCB Double Pole with way MCB BOX of Havells. 0 No. 9 5 Amp Combined Switch & Socket (Gang Box) Anchor make 0 No. 0 6 Amp Plug Top, Anchor. 0 No. 6 Amp Plug Top, Anchor. 0 No. TOTAL XXXXXX * ( B ) VOLTAGE STABILIZER FOR POWER VOLTAGE CONTROL WITH 3 YEARS REPLACEMENT WARRANTY S.NO. STABILIZER KVA SPACIFICATION REMARK STABLIZER VOLTAGE RANGE AVERAGE OF ( e) & ( f ) v V ( e ) + ( f ) / (a) ( b) ( c) ( d ) ( e ) ( f ) (g) 7.50 KVA Output Voltag = 0v+/- % per phase AUTO OF

18 ISI Make Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mode = Auto QUALITY (mentioned 0.00 KVA ISI Make Output Voltage = 0v+/- % per phase Max Temp rise = 45 degree C above ambient. Cooling = Air cooled Operation mod = Auto AUTO OF QUALITY ( mentioned 3 TOTAL XXXXX XXXXX * ( C ) WIRING FOR POWER SUPPLY BY SOLAR POWER PACK IN SELECTED BRANCHES S.NO MATERIAL DETAIL WITH LABOUR CHARGES QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( c ) x ( d )=( e) Wiring from output supply from solar power pack to four CFL of 5 watts and four ceiling fans. Wiring is to be done in casing. Wire to be used 0f.5 sq.mm for face and.5 sq.mm for neutral of Havells make. 00 meter Wiring from output power supply from solar power pack to four computers with TFT monitor, one pass book printer, one dot matrix printers, one scanner and power supply to V-SAT / Lease line modem/switch etc. Wiring is to be done in casing ( Havells make) 00 meter 3 Change over (Havells) for solar power supply and Grid power supply. 4 TOTAL XXXXXX ( X ) (D) DATA CABLING S.NO. DISCRIPTIONS MAKE QUANTITY UNIT COST TOTAL COST ( a ) ( b ) ( c ) ( d ) ( e ) ( d ) x ( e) =( f ) G 600 Cable Cat 6(copper UTP) D Link / Digi link 50 mts Information outlet Cat 6 (with single SMB), with D Link / Digi link 6 installation charges. 3 Patch panel Cat 6 ( port), with installation charges. D Link / Digi link 4 Patch cord mts. D Link / Digi link 06 5 Patch cord mts. D Link / Digi link 06 6 Steel rack (9U) wall mounted with 4-point power DB, one Valrack/ Digi link fan along with cable manager, with installation charges, setting of switch and router in rack with systemic manner. 7 Casing 9/9 mm, inch, AKG ( ISI) 75 mts 8 Casing 9/9 mm,.5 inch, AKG ( ISI) 75 mts 9 Structuring of data cabling. 50 mts 0 LAN Diagram (map) in 3 copies, one for branch, one for Regional office, One for IT department at Head office. Fixing of lease line / V-SAT Line in with clamps. XXXXXX TOTAL XXXXXX * (E) EARTHING WORK S.NO. PARTICULARS RATE

19 Ash safe earthing electrode, Mainntance free earthing with electrodes of 3.00 mts, diameter 46 mm to 50 mm, CPRI & RDSO tested :987 with two bag compound, electrodes (wire to be in PVC pipe duly clamped with wall) inclusive of all expances (EARTHING WORK WITH 3 YEAR WARRENTY) EARTH NUTRAL VOLTAGE IS ALWAYS REQUIRED TO BE LESS THAN VOLTS. Cost of 0.00 mm wire. TOTAL ( x ) Note: - All Quantities / Measurements are subject to final measurement on site in the presence of Branch Manager/ Regional Manager/ any Bank official from A&S department, Head office and are subjected to variation upto 0%.( + or - ) Terms and conditions:- A. All the materials which are to be used must be of specified brand / quality as narrated above. All the items must be of first quality, no second / commercial material are to be used having any type of defect. B. Before installation/ fitting, all the material must be inspected and approved by the Branch Manager/ Regional Manager/ any Bank official from A&S department, use of defective / sub standard / non approved / non specified items will not be accepted under any circumstances and the entire work will be rejected for such type of discrepancies. C. The work if ordered is required to be completed in stipulated time, delay will attract every block (each block consist of 7 days). D. Please quote your rates separately for each sets of districts (Annexure I to Annexure VI) for existing renovated branches/ proposed new branches to be opened.( Sets A to F) E. The quoted rates will be valid upto F. The wires to be used of Havells / Anchor/ Finolex make and of proper thickness as stipulated by the Bank. G. Bank reserves the right to reject one or all quotations without giving any notice, Bank may also call fresh tenders at a short notice. (FORMAT X) GRAMIN BANK OF ARYAVART HEAD OFFICE, A /46, VIJAYKHAND, GOMTINAGAR

20 LUCKNOW (U.P.) 600 Phone No /76/88/90-98, Fax No Id rrb.com Electrical, data cabling, ups wiring earthing work in existing /renovated branches / new Branches. Name of Firm / Organization. Address with Telephone No (I) Residence (ii)office/shop/godown. (iii) Website (iv) 3. Nature of Constitution of office/shop/ workshop 4. Date and year of Establishment 5. Name of the Proprietor/Partners/Directors with Residential address and Telephone No. (i) (ii) (iii) 6. Whether as S.S.I. unit if so, Reg. No. And Date. Also enclose copy of Certificate 7. Whether Registered with the Registrar of the Companies/Registrar of Firms. If so mention number and date. 8. Whether the premises (Press/Office/ Shop/ Factory) is/are owned or hired. 9. Name and address of the Banker's (Please enclose solvency certificate from the Banker's) 0. Whether registered for Trade-Tax Purposes. If so, mention No. And Date. Please also furnish Trade-Tax Clearance Certificate.. Whether an assessee of Income Tax if so, mention permanent account number. Please also furnish photocopy of income Tax return for the last three years.. Copies of Audited Balance Sheets and Profit & Loss Account Statement for the last 3 years to be furnished. 3. If registered in the panel of other Organizations. Statutory bodies furnish their names, category and date of registration. (i) (ii)

21 4. What are your lines of activities? Mention the fields on preference basis. (i) (ii) (iii) 5. Whether willing to work in GRAMIN BANK OF ARYAVART having its branches in Hardoi, Unnao, Lucknow, Barabanki,Faizabad, Kannauj, Farrukhabad, Mainpuri Ferozabad, Aligarh, Agra, Etah,Mathura, Hathras and Kasganj Districts. 6. (i) Detailed description and value of works done For others in the past.( Please photocopy of work orders) (ii) Detailed description and value of works done for the banks..( Please photocopy of work orders) 7. Specify the maximum value of works executed in a year. 8. Furnish the names of three responsible persons/bodies who will be in a position to certify about the quality as well as past performance of your organization. (i) (ii) (iii) 9. Names and addresses of the principal customers (Enclose certified copies of the latest orders). Note: Where copies are required to be furnished these are to be certified preferably by the concerned agencies or a Government Officer. PROFORMA I PARTICULARS IN RESPECT OF THE WORK EXECUTED DURING LAST THREE YEARS Name of Work/Project with address Short Name and description Address of work owner executed Value of work executed Stipulated time of completion Actual time of completion OTHER RELEVANT INFORMATION. Whether worked for the Comercial Banks / Gramin banks, if yes, since when & for which Commercial Banks / Gramin Bank.

22 . Capacity to execute one time order (Please mentioned the total amount and delivery period required) 3. Any other information. WORK FORCE KEY PERSONNEL PERMANENTLY EMPLOYED Permanently Employed No. Since when in the Employment Others OFFICE/ WORKSHOP/STORAGE FACILITIES Location Land Area Owned /Rented Type of Structure Type of Facility( Brief particulars of machines/ equipments) I/We declare that the particulars furnished above are true and correct and I shall abide by all the terms and conditions of the empanelment. And fully agree with the conditions / norms of the Bank,In case any information/particular is found incorrect at a later date, the application/empanelment is liable to be cancelled. Date: Place: Signature of the Applicant. (With Rubber Stamp)

GRAMIN BANK OF ARYAVART

GRAMIN BANK OF ARYAVART GRAMIN BANK OF ARYAVART HEAD OFFICE, A /6, VIJAYKHAND, GOMTINAGAR LUCKNOW ( U.P.) 600 Phone No- 7388800775/76/88/90-98, Fax No. 05-39986 Email Id www.aryavart rrb.com HO/A&S/VKS/ 66 DATE 8.07.03 TENDER

More information

Supply of Batteries

Supply of Batteries Supply of Batteries 207-8 SUPPLY OF BATTERIES OF VARIOUS RATINGS E-PROCUREMENT (REVERSE AUCTION) NIT No: 07/ 207-8 Name of the work Supply of Batteries to our Branches / Offices /ATM Completion Time EMD

More information

PART B: FINANCIAL BID

PART B: FINANCIAL BID Relationship beyond Bankjng TENDER DOCUMENT FOR ELECTRICAL (ELECTRICAL & DATA CABELING WORK ONLY) IN BANK OF INDIA BRANCH AT SECTOR 25 PANCHKULA BANK OF INDIA, ZONAL OFFICE, S.C.O. NO. 76-82, SECTOR 31-A,

More information

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm TENDER Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm On behalf of INDIAN INSTITUTE OF INFORMATION TECHNOLOGY & MANAGEMENT KERALA (IIITMK), the Registrar invites offers for supply and laying

More information

REGIONAL MANAGER (VADODARA REGION)

REGIONAL MANAGER (VADODARA REGION) Tenders Quotation are invited to conduct electric audit of branches in Vadodara Region, Gujarat State Dena Bank intends to conduct electrical audit in our all 74 branches including Regional Office, Vadodara,

More information

Section VI: List of Requirements (REVISED)

Section VI: List of Requirements (REVISED) As per Technical Specifications attached in Section VII Date: 18/06/2018 of Electrical Items With reference to the above tender, the following Corrigendum may kindly be noted against the Section VI, Section

More information

Hkkjrh; izca/k lalfkku dksf"kddksm

Hkkjrh; izca/k lalfkku dksfkddksm Hkkjrh; izca/k lalfkku dksf"kddksm vkbz- vkbz-,e- dksf"kddksm dseil (ih-vk-s), dksf"kddksm 673 570, dsjy INDIAN INSTITUTE OF MANAGEMENT, KOZHIKODE IIM Kozhikode Campus P.O. Kozhikode- 673 570 Phone: 0495

More information

NOTICE INVITING QUOTATIONS

NOTICE INVITING QUOTATIONS MALAVIYA NATIONAL INSTITUTE OF TECHNOLOGY JAIPUR No. F5(4020)ST/MNIT/Estate/2017 Phone : 0141-2713312,2713352 M/s......... NOTICE INVITING QUOTATIONS 1 Fax No. : 0141-2529078 1. Registrar, MNIT, Jaipur

More information

Ref. No: 01/Electric/KC/Pc/17 Date: 24/11/2017

Ref. No: 01/Electric/KC/Pc/17 Date: 24/11/2017 KATWA COLLEGE (Affiliated to the UNIVERSITY OF BURDWAN) Principal s Office KATWA 713 130 BURDWAN Tel.: (03453) 255049 E-mail: katcoll2009@gmail.com Website: www.katwacollege.ac.in Ref. No: 01/Electric/KC/Pc/17

More information

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB / Bill of Quantity for Electrical & Computer wiring works for Shifting of RACPC Jamshedpur to new location of Jamshedpur Branch Premises S.No. Item Description Qty. Rate Amount 1 UPS DB / COMPUTER DB Supply

More information

SPECIFICATIONS OF ITEMS ANNEXURE-1A Sr. No. Item specification Qty. (in nos.) 1 Computer chair with armrest Approximate Size: Width 64 cm Depth 64cm Height 81.0-93.5 cm Seat Height 42-54.5 as Godrej Model

More information

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. TENDER SCHEDULE -1-1 2 3 4 5 6 7 1 208 Point Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

(LAST DATE OF SUBMISSION: ) QUOTATION FOR ANNUAL MAINTENANCE CONTRACT OF SERVERS, COMPUTERS, PRINTERS, NETWORKING AND LAN

(LAST DATE OF SUBMISSION: ) QUOTATION FOR ANNUAL MAINTENANCE CONTRACT OF SERVERS, COMPUTERS, PRINTERS, NETWORKING AND LAN Government of India Ministry of Communications and IT Department of Telecommunications O/o Controller of Communication Accounts Room No. : A-403, 3 rd Floor, ARTTC Building, Near Jumar River Bridge, NH-33,

More information

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells

M. C. B. / D. B./MCCB : MDS/Schneider/Siemens/havells Material Specification for Electrical Work Tube Light : Phillips, GE Switches : / Legrand (Artiar )/Anchor roma Wire/Cable : Anchor/Finolex/National /Havells/ CCI Fan : Crompton Greaves ( high Breeze )/USHA

More information

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore -452003 (M.P.) ANNEXURE -III REQUIREMENT OICL intends to procure reputed brand Exide or Amara Raja or

More information

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises S.No. Item Description Qty. Rate Amount 1 Removing and Reinstallation of Main Incoming

More information

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH S.NO. PARTICULARS QTY. UNIT RATE AMOUNT ELECTRICAL WORKS 1 LIGHT AND FAN POINT WIRING Suppling receving, storing, handling, fixing,

More information

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana -504107 Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated. 17.12.2018 NOTICE INVITING QUOTATIONS Description : Supply of Electrical

More information

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes. PRICE FORMAT FOR SUPPLY OF ELECTRICAL ITEMS PART B PRICE BID TITLE: PROCUREMENT OF ELECTRICAL ITEMS IN BHEL TOWNSHIP, SECTOR 17, NOIDA NIT NO: 08:AA:NOI:ADMN:Electrical Items :112:2013 14 Dated 02/08/2013

More information

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Tender Schedule. Sl. No. Particulars Quantity Unit Rate ` Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

PART A: FINANCIAL BID

PART A: FINANCIAL BID TENDER DOCUMENT FOR INTERIOR FURNISHING WORKS (excluding ELECTRICAL & DATA CABELING WORK) IN BANK OF INDIA BRANCH AT FARIDABAD,(SME BRANCH), HARYANA BANK OF INDIA, ZONAL OFFICE, STAR HOUSE, S.C.O. NO.

More information

ZONAL OFFICE KEONJHAR ZONE

ZONAL OFFICE KEONJHAR ZONE ZONAL OFFICE KEONJHAR ZONE Labanya Square, Mining Road, Keonjhar-758001 ELECTRICAL & DATA CABLING WORK OF BANK OF INDIA, Hatadihi BRANCH AT Hatadihi, Po: Hatadihi, DIST- Keonjhar NOTICE INVITING TENDER

More information

University of Peradeniya INVITATION FOR BIDS

University of Peradeniya INVITATION FOR BIDS University of Peradeniya INVITATION FOR BIDS 1) The Chairman of University Procurement Committee, invites sealed bids from authorized local lessors to procure following vehicles through operational lease

More information

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING To, Ref No: IIT/ EE/SMART CITY/INVERTER AND BATTERY SET/2015/02 INVITATION FOR QUOTATIONS FOR SUPPLY OF THE FOLLOWING ITEMS REQUIRED FOR SMART CITY PILOT PROJECT AT IIT KANPUR S.No. Brief Description of

More information

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH 1. WIRING TO POINTS 1 Recess conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper FRLS wire

More information

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI

GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI GUWAHATI MUNICIPAL CORPORATION WATER WORKS :: PANBAZAR GUWAHATI-781001 DETAILED QUOTATION NOTICE & DOCUMENTS NAME OF WORK:- Annual quotation for supply of spare parts for machineries for the year 2017-2018.

More information

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing

More information

SCHEDULE OF QUANTITY

SCHEDULE OF QUANTITY SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red

More information

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station.

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station. ORISSA POWER GENERATION CORPORATION LIMITED IB THERMAL POWER STATION AT/P.O: BANHARPALI, DIST: JHARSUGUDA, PIN: 768234 (ORISSA), INDIA GRAM: IB THERMAL, TEL: 06645-222209/222210, FAX: 06645-222209/54/30

More information

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura - 586109 Diesel Generator Required on Rental Basis Bank desires to hire diesel generator on rental basis for the following

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

Solar Energy Corporation of India Limited New Delhi Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India

Solar Energy Corporation of India Limited New Delhi Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India SECI/SD/EoI/20000 MW Mfg./I/2017 18.12.2017 Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India 1. Objective of EOI: SECI intends to invite Expression of Interest from the

More information

FORMAT B (Annexure-III)

FORMAT B (Annexure-III) FORMAT B (Annexure-III) Bill of Quantities AR&M works (Electrical) Residential buildings Part-I (Schedule items) Sl. No. Description of Items Unit Qnty. Rate in figure 01 Point Wiring in PVC Conduit with

More information

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1 Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM SCOOTERS INDIA LIMITED Page 1 THIS PAGE INTENTIONALLY LEFT BLANK SCOOTERS INDIA LIMITED Page 2 SCOOTERS INDIA

More information

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR Unique No.* Name of Work Name of Department Tender No.* Complete Mechanical works, Electrical works, Body works,

More information

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD Soubhagya Nayak Associates Plot No-736,Sector-3,Niladrivihar,Chandrasekharpur,Bhubaneswar.21

More information

FORMAT-III B - ANNEXURE-III

FORMAT-III B - ANNEXURE-III FORMAT-III B - ANNEXURE-III Bill of Quantities AR&M works (Electrical)Residential buildings Part-I (Schedule items) Sl. Description of item Unit Qty No. In Figure Point Wiring in PVC Conduit with piano

More information

ANNEXURE-I CHECK LIST FOR APPLICATION FORM

ANNEXURE-I CHECK LIST FOR APPLICATION FORM ANNEXURE-I CHECK LIST FOR APPLICATION FORM S.No. DOCUMENTS REQUIRED SUBMITTED 1 Application Form must be signed by Registered Consumer on each page with stamp 2 Occupancy Proof along with roof rights (Registered

More information

APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES. Disclaimer

APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES. Disclaimer APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES Disclaimer SHCIL Services Limited (SSL) makes no representation or warranty and shall incur no liability under any law, statute, rules

More information

Appendix I 1. Name of the Agency: HANDLOOM EXPORT PROMOTION COUNCIL TECHNICAL BID 2. Address: 3. Name of the authorised person 4. Telephone No: Office: Mobile: Residence: Fax: 5. Documents to be enclosed:

More information

TENDER DOCUMENT PART-II

TENDER DOCUMENT PART-II 1 NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT TAMILNADU REGIONAL OFFICE TENDER DOCUMENT PART-II (PRICE BID) Supply, Installation, Testing and Commissioning of 25 kva DG Sets with Acoustic Enclosure

More information

FORMAT-III B - ANNEXURE-IV

FORMAT-III B - ANNEXURE-IV FORMAT-III B - ANNEXURE-IV Bill of Quantities AR&M works (Electrical) Non-Residential buildings Part-I (Schedule items) Sl. No. 1 Description of item Unit Qty Point Wiring in PVC Conduit with piano type

More information

Amount (Rs) 1.5 sq. mm ISI marked, FR

Amount (Rs) 1.5 sq. mm ISI marked, FR BILL OF QUANTITY FOR ELECTRICAL WORK AT ESI REGIONAL OFFICE, STAFF QUARTERS, SEC-16 AND ASSOCIATED BRANCH OFFICE AND DISPENSARY. Part-II Sr. no SOR No. Details of Items Unit Quantity Rate (Rs) Amount (Rs)

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the

More information

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. S.No Particulars Qty Unit Rate Rs Amount Rs Service Connection

More information

Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED

Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED Annexure- II (Price Bid) SCHEDULE B LIST OF ELECTRICAL ITEMS TO BE SUPPLIED A BULBS Philips/wipro/osram/Havells Nos. 1 10 W 2 Pin (Zero) Night Lamp 300 Nos. (B-22) 2 40W Small Screw Type Candle 300 Nos.

More information

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount 1 2 Writing for light point/ fan point/ exhaust fan point /call bell point with 1.5 sq.mm FR PVC insulated

More information

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia. Supply, Installation and Commissioning of 1 No 50 Watt LED based SPV SLS at Nadia District Library, Krishna Nagar, Nadia. TENDER DOCUMENT. (A Govt. of West Bengal Company) Bikalpa Shakti Bhavan, Plot J1/10,

More information

Section II -Technical Specification

Section II -Technical Specification Page 1 of 9 1 Place where equipment to be CPRI campus Bengaluru supplied 2 Scope (supply / supply & Installation / suply, installation & training) Periodical inspection and service of the unit once in

More information

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website: TENDER DOCUMENTS FOR

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website:  TENDER DOCUMENTS FOR Cost of the Tender Form - Rs.500/- (Rupees Five Hundred only) Tender Form No.MCI/TENDER DGSET/2018 Tender for DG SET MEDICAL COUNCIL OF INDIA POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI 110 077 Website:

More information

SAVE ENERGY FOR BENEFIT OF SELF AND NATION

SAVE ENERGY FOR BENEFIT OF SELF AND NATION Taluka: Thasra Dist : Kheda Pin: 388 239 Telephone No. 02699-235 522 Fax No. 02699-235 607 CHIEF ENGINEER (C&O), GSECL,, INVITES TENDERS FROM INTERESTED BIDDERS, FOR SUPPLY OF ABOVE MATERIAL. THE DETAILS

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

LIPA Plug In Electric Vehicle Rebate

LIPA Plug In Electric Vehicle Rebate This does not constitute tax advice. All persons considering use of available incentives should consult with their own tax professional to determine eligibility, specific amount of benefit available, if

More information

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

Supply of 63 kva DIESEL GENERATOR SET WITH AMF No. NIQ/INKEL/2015-16/162 24 TH Nov 2015 NOTICE INVITING QUOTATION Sealed Quotations are invited for and on behalf of INKEL Limited, having its registered office at INKEL Centre, Off Vallathol junction,

More information

FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH

FINANCIAL BID NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH FINANCIAL BID S. No. 1 2 3 4 5 6 7 8 9 10 11 12 NAME OF WORK : ELECTRIFICATION WORK AT THE NEW OFFICE PREMISES OF SBI EXCLUSIF KOZHIKODE BRANCH DESCRIPTION QTY UNITS RATE AMOUNT SETC of a KSEB Metering

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48 INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/48 29-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES. Disclaimer

APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES. Disclaimer APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES Disclaimer Stock Holding Corporation of India Limited SHCIL makes no representation or warranty and shall incur no liability under

More information

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517 HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517 Website: www.hpgcl.org.in E-mail- ceplg@hpgcl.org.in EXPRESSION

More information

Guidelines for Registration of Private / Transport Vehicles

Guidelines for Registration of Private / Transport Vehicles Guidelines for Registration of Private / Transport Vehicles A vehicle Registration Certificate is an official document providing proof of registration of a motor vehicle. It is used primarily by the government

More information

TECHNICAL BID T 3627

TECHNICAL BID T 3627 TECHNICAL BID T 3627 Supply of Mechanical Measuring Instruments for TMD-II OF UKAI TPS. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly

More information

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet. SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH B.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH SL.N 1. WIRING TO POINTS 1.0 Concealed conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description

More information

APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES Disclaimer

APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES Disclaimer APPLICATION FORM FOR EMPANELMENT OF VENDOR FOR IT PRODUCTS & SERVICES Disclaimer Stock Holding Corporation of India Limited SHCIL makes no representation or warranty and shall incur no liability under

More information

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV.CAPACITOR BANK 1.0 SCOPE: This specification covers

More information

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE:

More information

Note: it is a criminal offence to give false information in this application.

Note: it is a criminal offence to give false information in this application. Note: it is a criminal offence to give false information in this application. Section 1 - Your contact details (Please read Guidance Note 1) 1a) Please give full details of the person that can be contacted

More information

Municipality Generator Interconnection Application Single Meter Application Part I

Municipality Generator Interconnection Application Single Meter Application Part I Municipality Generator Interconnection Application Single Meter Application Part I New Application Revised Application A single customer interconnecting to a single meter at a single premise makes a new

More information

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02 Tender No:- MTL/PUR/213/Elect/2015-16 (K)/9 Date:-26/10/2016 Type Of Bid Bidding type Bid closing On Bid Opening On EMD : LIMITED TENDER : Single Bid : 18/11/2016 at 14.00 hrs.(ist) : : As per Annexure

More information

2017 Commercial & Industrial Program K-12 Schools Program Rebate Application

2017 Commercial & Industrial Program K-12 Schools Program Rebate Application MEMBER INFORMATION Member Name Company Name Mailing Address City State ZIP Phone Email Electric Cooperative/REMC Name (MUST be completed) Electric Cooperative/REMC Account Number (MUST be completed) Check

More information

(URL: F /KV Damoh/ / Date:

(URL:    F /KV Damoh/ / Date: क न द र य व द य लय दम ह KENDRIYA VIDYALAYA DAMOH ककल ल ई न क ब ल क ट र ड, दम ह-(म.प र.) 470661 KILLAI NAKA BALAKOT ROAD DAMOH (M.P) 470661 (URL:www.kvdamoh.edu.in, e-mail: damohkv@gmail.com,phone-223224

More information

Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad.

Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad. Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad. Amendment to Tender Reference No. BL/LI/CC/HYD/22 Date

More information

REQUEST FOR PRICE QUOTATION FOR Laser Toner Cartridges. DATE BIDS REQUESTED: June 24, 2009 WEDNESDAY 10:30 A.M BID # RETURN TO:

REQUEST FOR PRICE QUOTATION FOR Laser Toner Cartridges. DATE BIDS REQUESTED: June 24, 2009 WEDNESDAY 10:30 A.M BID # RETURN TO: REQUEST FOR PRICE QUOTATION FOR Laser Toner Cartridges DATE BIDS REQUESTED: June 24, 2009 WEDNESDAY 10:30 A.M BID #09-003 RETURN TO: DR. PAM BEST, INTERIM SUPERINTENDENT LOUISBURG UNIFIED SCHOOL DISTRICT

More information

Tender Enquiry No: BCL / PUR / ARC / AC&DC Motors/ CW / 2019 Dated: Due on:

Tender Enquiry No: BCL / PUR / ARC / AC&DC Motors/ CW / 2019 Dated: Due on: MINISTRY OF RAILWAYS HEAD OFF. & REGD. OFF. : 5, HIDE ROAD, KOLKATA 700 043 TEL: +91 33 2439-7415, 2439-4114, 2439-6613, 2439-7413, FAX: +9133 2439 7632/ 5607 E-mail: purchase@braithwaiteindia.com Website:

More information

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / 2005-06 SR.NO ITEM PAGE 1. SCOPE 2 2. WEATHER CONDITIONS 2 3. RATED VOLTAGE & FREQUENCY 2 4. GENERAL REQUIREMENT

More information

A summary of the vehicle to be purchased: Department Type of Vehicle Quantity Stormwater Department One Ton Dual Rear Wheel Dump Truck w/ Bed 1

A summary of the vehicle to be purchased: Department Type of Vehicle Quantity Stormwater Department One Ton Dual Rear Wheel Dump Truck w/ Bed 1 City of Cartersville P.O. Box 1390 1 North Erwin Street Cartersville, GA 30120 DATE: January 24, 2018 TO: FROM: RE: Automobile Dealers Fleet Sales Personnel Tom Rhinehart, Finance Director Vehicle Bids

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED GUIDELINES FOR EMPANELMENT OF GRID TIED INVERTER MANUFACTURERS FOR IMPLEMENTATION OF SRTPV PROGRAM IN BESCOM. I. NEW EMPANELMENT 1. The grid tied inverter manufacturer shall register their application

More information

Technical Specifications

Technical Specifications LT Distribution Box Technical Specifications 1. SCOPE 1.1 This specification covers design, manufacture, testing at manufacturer works before dispatch and supply of L.T. Distribution Cabinet suitable for

More information

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ)

STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA. ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ) FINANCIAL BID STATE BANK OF INDIA ADMINISTRATIVE OFFICE -7 : HUBBALLI KUDRIGE BRANCH - REGION 5, KARNATAKA ELECTRICAL WORKS : SCHEDULE OF ITEMS(BOQ) PART A SL No DESCRIPTION OF WORK QTY UNIT SUPPLY ERECTION

More information

INVITATION TO BID SPECIFICATIONS & INSTRUCTIONS FOR:

INVITATION TO BID SPECIFICATIONS & INSTRUCTIONS FOR: INVITATION TO BID SPECIFICATIONS & INSTRUCTIONS FOR: HOMEWOOD-FLOSSMOOR PARK DISTRICT Golf Car Lease/Purchase Coyote Run Golf Course Flossmoor, IL 60422 BID OPENING ON: Thursday, October 25, 2018 TIME:

More information

REVISED REQUEST FOR QUOTATIONS FOR PRINTING SERVICES Food and Nutrition Technical Assistance Project III (FANTA)

REVISED REQUEST FOR QUOTATIONS FOR PRINTING SERVICES Food and Nutrition Technical Assistance Project III (FANTA) November 02, 2017 REVISED REQUEST FOR QUOTATIONS FOR PRINTING SERVICES Food and Nutrition Technical Assistance Project III (FANTA) Issue date: Nov 2, 2017 Submit Questions by: Submission Deadline: Contact

More information

/ Telefax : No: 1(2)2015-E/ Battery& Charger TVH/ Dated:

/ Telefax : No: 1(2)2015-E/ Battery& Charger TVH/ Dated: प रस र भ रत / PRASAR BHARATI (भ रत य ल क स व प रस रक / INDIA S PUBLIC SERVICE BROADCASTER) द रदर शन क न द र / DOORDARSHAN KENDRA ह दर ब द / HYDERABAD 500 013.. Email : sgeddh@yahoo.com / sgeddh@gmail.com

More information

COMMERCIAL MOTORS & VARIABLE SPEED DRIVES REBATE APPLICATION

COMMERCIAL MOTORS & VARIABLE SPEED DRIVES REBATE APPLICATION COMMERCIAL MOTORS & VARIABLE SPEED DRIVES REBATE APPLICATION 1. CUSTOMER INFORMATION (please print) Business Name Location Name or DBA (if different from Business Name) Installation Address City State

More information

RMS CONDITIONAL REGISTRATION SCHEME HISTORIC (CRS-H) RULES FOR MEMBERS. Mustang Owners Club Australia (N S W) Inc.

RMS CONDITIONAL REGISTRATION SCHEME HISTORIC (CRS-H) RULES FOR MEMBERS. Mustang Owners Club Australia (N S W) Inc. Mustang Owners Club Australia (N S W) Inc. Email: cpregistrar@nsw.mustang.org.au 1-12-16 INTRODUCTION 1. The Mustang Owners Club of Australia (NSW) Inc. (herein known as the Club ) is approved by the Roads

More information

Construction and Connection of Street Light Assets

Construction and Connection of Street Light Assets Construction and Connection of Street Light Assets 1. INTRODUCTION... 2 2. FURTHER INFORMATION... 3 3. DEFINITIONS... 3 3.1 Designer... 3 3.2 Street Light Asset Owner... 3 3.3 Road Owner... 4 3.4 Developer...

More information

TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR LAST DATE OF RECEIVED OF TENDER DOCUMENTS :

TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR LAST DATE OF RECEIVED OF TENDER DOCUMENTS : TENDER DOCUMENTS SUPPLY OF ELECTRICAL EQUIPMENT FOR BHADRAK MUNICIPALITY FOR THE YEAR 2016 17 PERIOD OF SALE OF TENDER DOCUMENTS : 27.05.2016 LAST DATE OF RECEIVED OF TENDER DOCUMENTS : 10.06.2016 DATE

More information

Town of Centreville Automated Speed Enforcement Program

Town of Centreville Automated Speed Enforcement Program Frequently Asked Questions: Town of Centreville Automated Speed Enforcement Program What is Automated Speed Enforcement In October 2009 the State of Maryland authorized the use of Automated Speed Monitoring

More information

Supply & Installation of Latest Version NX CAD Academic Software (NX9)

Supply & Installation of Latest Version NX CAD Academic Software (NX9) ISO 9001:2008 TENDER FOR Supply & Installation of Latest Version NX CAD Academic Software (NX9) Tender Inquiry No. NSIC/NTSC/CAD/CAM/CNC/UG- NX Software/051/15-16 NSIC- Technical Services Centre (A Government

More information

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number:

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number: Please print the following information. Interconnect Customer Information Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone

More information

THE CORPORATON OF THE TOWN OF MIDLAND VEHICLE TOWING AND POUND SERVICES 2018/2019 TENDER L

THE CORPORATON OF THE TOWN OF MIDLAND VEHICLE TOWING AND POUND SERVICES 2018/2019 TENDER L THE CORPORATON OF THE TOWN OF MIDLAND VEHICLE TOWING AND POUND SERVICES 2018/2019 TENDER L04-54474 MAY, 2018 TOWN OF MIDLAND TENDER VEHICLE TOWING AND POUND SERVICES SEALED TENDERS will be received until

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

FORM 20 [See Rule 47] APPLICATION FOR REGISTRATION OF A MOTOR VEHICLE

FORM 20 [See Rule 47] APPLICATION FOR REGISTRATION OF A MOTOR VEHICLE FORM 20 [See Rule 47] APPLICATION FOR REGISTRATION OF A MOTOR VEHICLE (To be made in duplicate if the vehicle is held under an agreement of Hire-Purchase/Lease/Hypothecation and duplicate copy with the

More information

TECHNICAL BID T 3610

TECHNICAL BID T 3610 TECHNICAL BID T 3610 Supply of Various Rubber Items at GSECL TPS Ukai. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly Notarized : YES

More information

SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT

SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT 1 SPECIFICATIONS OF SINGLE GIRDER UNDER SLUNG E.O.T. CRANE CAPACITY: 5 MT QUALIFICATION CRITERIA Vendor has to compulsorily meet the following requirements to get qualified for consideration of the technical

More information

Dakshin Gujarat Vij Company Limited

Dakshin Gujarat Vij Company Limited Dakshin Gujarat Vij Company Limited CIN U40102GJ2003SGCO42909 Regd. & Corporate Office: Urja Sadan, Nana Varachha Road, Kapodara Char Rasta,Surat 395 006 C & R DEPARTMENT Phone No.: 0261 2506100-200-175

More information

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY

THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY THE CONNECTICUT LIGHT AND POWER COMPANY dba EVERSOURCE ENERGY AND THE UNITED ILLUMINATING COMPANY Virtual Net Metering Application Effective November 18, 2016 This application form addresses virtual net

More information

HALIFAX REGIONAL MUNICIPALITY (HRM) One (1) Loader Mounted Snow Blower TENDER # T Page 1

HALIFAX REGIONAL MUNICIPALITY (HRM) One (1) Loader Mounted Snow Blower TENDER # T Page 1 Page 1 TENDER OF: ADDRESS: CONTACT NAME: TELEPHONE: FAX #: GST REGISTRATION #: To furnish and deliver equipment in accordance with specifications annexed hereto. The undersigned bidder has carefully examined

More information

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read Tender for procurement of Passive Components of LAN & Wi-Fi and their installation Corrigenda Sl. No. Annexure/Clause For Read Item Specifications Item Specifications 1. Annexure-I, Point No. 1.3 24 Port

More information