Hedeager Aarhus N Denmark

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Hedeager Aarhus N Denmark"

Transcription

1 Certificate No. This certificate is issued to for the wind turbine wind turbine class (class, standard, year) Vestas Wind Systems A/S Hedeager Aarhus N Denmark Vestas V100-2 MW 60 Hz VCSS Mk 10 WT class S, IEC : 2005+Amd1: 2010 This certificate is transferred from IEC to IECRE and attests compliance with IEC Series as specified in subsequent pages. It is based on the following reference documents: Design basis evaluation conformity statement Design evaluation conformity statement Type test conformity statement Manufacturing conformity statement Final evaluation report DB-DNVGL-SE DE-DNVGL-SE TT-DNVGL-SE ME-DNVGL-SE FER-TC-DNVGL-SE The conformity evaluation was carried out in accordance with the rules and procedures of the IECRE System The wind turbine type specification begins on page 2 of this certificate. Changes in the system design or the manufacturer s quality system are to be approved by the Certification Body. Without approval, the certificate loses its validity. This certificate is valid until: Approved for issue on behalf of the IECRE Certification Body: Mark Wollenberg / Christer Eriksson Project Manager / Service Line Leader, Type Certification Hellerup Renewables Certification Brooktorkai Hamburg, Germany Issued /9

2 Machine parameters: Power regulation: Rotor orientation: Number of rotor blades: 3 Rotor tilt: 6 Cone angle: 3 pitch-controlled upwind Rated power: kw (refer to annex 1 for details) 2000 kw: derating strategy for cooler top 30 at ambient temperature above 35 C 2000 kw: derating strategy for cooler top 40 at ambient temperature above 40 C 2200 kw: derating strategies for ambient temperature above 30 C Rated wind speed Vr: 10.0 m/s (2000 kw) 10.3 m/s (2200 kw) Rotor diameter: 100 m Hub height(s): Hub height operating wind speed range Vin Vout: Design life time: 75 m, T2X m, T2X202, T2X m, T2X221 (refer to annex 1 for details) 3-22 m/s 20 years Software version: VMP Global Wind conditions: Characteristic turbulence intensity Iref at Vhub = 15 m/s: See annex 1 Annual average wind speed at hub height Vave : See annex 1 Reference wind speed Vref : See annex 1 Weibul shape factor (k) See annex 1 Mean flow inclination: 8 Hub height 50-year extreme wind speed Ve50: See annex 1 Electrical network conditions: Normal supply voltage and range: V V Normal supply frequency and range: 60 Hz Voltage imbalance: <3 % Maximum duration of electrical power network outages: Not dimensioning Number of electrical network outages 50 / year Issued /9

3 Other environmental conditions (where taken into account): Normal and extreme temperature ranges: Standard turbine -20 C to +45 C -30 C to +50 C Low temperature turbine (LT) -30 C to +45 C -40 C to +50 C Low temperature turbine (LT), turbine components and operating strategy are identical to the standard temperature turbine, but additional heating elements are installed for low temperature usage Relative humidity of the air: 100 % (max 10 % of lifetime) Air density: Standard turbine kg/m 3 Low temperature turbine kg/m 3 The -30 C minimum operating temperature has been verified for loads and structural integrity by considering an air density of kg/m 3 Solar radiation: Lightning protection system (standard and protection class): The turbine shall resist solar radiation (including UV) with 1000 W/m 2 and 8000 MJ/m 2 per year throughout the design lifetime IEC :2010, Protection Level 1 Issued /9

4 Major components: **If not otherwise stated, the certificate holder is the manufacturer. Blade: Material: Blade length: Number of blades: 3 Prepreg Vestas Glass fibre and carbon fibre reinforced epoxy 49m Vestas item number Blade bearing: 2 row 4-point contact ball bearing Rollix DD0-5 Blade bearing: 2 row 4-point contact ball bearing Liebherr 648 VO Blade bearing: 2 row 4-point contact ball bearing TMB B K Pitch System: Motor / Actuator Pitch Controller One hydraulic cylinder per blade Hydraulic LJM Issued /9

5 Pitch System: Motor / Actuator Pitch Controller One hydraulic cylinder per blade Hydraulic Glual Pitch System: Motor / Actuator Pitch Controller One hydraulic cylinder per blade Hydraulic Hine Main shaft: Forged hollow trumpet shaft Material: 42CrMo Main bearing: Two double row spherical roller bearing SKF 230/630 CA/HM2 W ECA/HM2 W33 Main bearing: Two double row spherical roller bearing KOYO 230/630 RHAW33T RHAW33 Main bearing: Two double row spherical roller bearing FAG F PRL-WPO F PRL-WPO Gearbox: 3 stage planetary gearbox Issued /9

6 Winergy Gear Ratio: 1:89.75 PEAB 4440 Gearbox: 3 stage planetary gearbox ZF Gear Ratio: 1:89.8 Atlas 1.0, 1.1, 1.2, 1.21 Yaw System: Drive Electrical motor ABB or Lafert Bearing Friction Bearing (PETP slide plate) Vestas Wind System A/S V01 Gear Planetary-/worm gear combination Bonfiglioli, Comer (left) / (right) Brake Friction brake, motor brake included in the drive unit ABB or Lafert Generator: Type Rated Power: DVSG 500/6M (Three phase Asynchronous generator with wound rotor) Vestas Wind System A/S 2060 kw or 2260 kw Issued /9

7 Rated Frequency: Rated Speed: Rated Voltage: Rated Current: Insulation Class: Degree of Protection: 60 Hz 1344 rpm 690 VAC 1558 A or 1708 A H/H IP V0 (2060 kw) V0 (2260 kw) Converter: Rated Voltage (grid side): Full quadrant IGBT Vestas Wind System A/S 480 V Nominal current (at 2.0 MW) Grid Rotor Nominal current (at 2.2 MW) 240 A 592 A Grid 256 A Rotor 655 A Degree of Protection: IP 54 Transformer: Rated Voltage: Dry type Siemens HV side: V LV side: 690 V +/-2% & 480 V +/-2% Transformer: Rated Voltage: Dry type SGB HV side: V LV side: 690 V +/-2% & 480 V +/-2% Transformer: Dry type Issued /9

8 Rated Voltage: JST HV side: V LV side: 690 V +/-2% & 480 V +/-2% Tower: Tubular steel Sections: 4 Hub height: 80 m V2 (T2X202) Tower: Tubular steel Sections: 3 Hub height: 80 m V1 (T2X203) Tower: Tubular steel Sections: 4 Hub height: 95 m V2 (T2X221) Tower: Tubular steel Sections: 4 Hub height: 75 m V0 (T2X302) Manuals: Operation & maintenance manual: Transport manual: Installation & commissioning manual: See list of manuals V01 See list of manuals V01 See list of manuals V01 Issued /9

9 Annex 1 Configuration matrix Wind turbine class Tower Rated power (kw) V ave (m/s) V ref (m/s) v e50 (m/s) I ref Weibull (k) S (2C*) T2X S T2X S (2B*) T2X S T2X S (2B*) T2X S T2X S (2B*) T2X S T2X * Only temperature levels (LT) deviate from this turbine class Issued /9