INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOGUE M950 FEBRUARY 2013

Size: px
Start display at page:

Download "INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOGUE M950 FEBRUARY 2013"

Transcription

1 Twin City an INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS RADIAL TIP ANS MODEL RT CATALOGUE M90 EBRUARY

2 RADIAL TIP ANS Model RT Model RT radial tip fans are of a heavy duty, rugged design, suitable for applications involving large volumes of gas streams at moderate to high pressure. Designed to handle clean or dirty airstreams, they are widely used to exhaust gases from bag-type collectors, precipitators, scrubbers, cyclones, and other industrial applications. This type of fan is also used for induced draft on boilers, incinerators, and kiln exhaust. Steel, air pollution, dryer, petrochemical, cement, furnaces and ovens, solvent recovery, sewage sludge and solid waste incineration industries have found the Model RT radial tip design particularly suitable for their applications. Model RT Arr. Capabilities Heavy-duty construction with choice of speed range: Class 8 Suitable to 9 m/s tip speed Pressures to 960 Pa Class Suitable to m/s tip speed Pressures to 890 Pa Class Impellers are equipped with wear pads on the blades. Consult factory for higher tip speed designs. Volume flow to 6 m /sec. Standard fan suitable to 48 C. eatures High efficiency, for lower operating costs. AMCA licensed air performance on sizes 0 through, pages to. Self-cleaning impeller design. Statically and dynamically balanced rotor assembly. Heavy duty, self-aligning, grease lubricated, antifriction, pillow block bearings. Heavy-gauge reinforced housing and bearings pedestal for vibration-free service. Twin City an & Blower certifies that the RT Radial Tip ans Sizes 0 through shown on pages to are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and comply with the requirements of the AMCA Certified Ratings Program. Twin City an TWIN CITY AN - CATALOGUE M90

3 ACCESSORIES Inlet Boxes Integral or detached type, generously designed to minimise pressure drop. Specify inlet box position to AMCA Standard shown on page 4. Detached inlet boxes include support legs and flanges on both inlet and outlet. ree-standing designs are also available to allow a flexible connector between box and fan. Standard detached inlet box will not support stack weight. All inlet box designs include drain and access door. Inlet Box Dampers Pre-spin design, heavy duty construction. The damper will spin the air in the direction of impeller rotation resulting in a savings in horsepower at reduced loads. Outlet Dampers Double surface airfoil blades are available in either parallel or opposed blade design. Temperature and Vibration Detectors Thermocouples or RTDs can be installed on the bearings. Various types of vibration switches are available. Evasé Usually fabricated by customer as a part of the ductwork. an outlet must be expanded to equal evasé area shown in the catalogue to obtain rated performance. Construction is of the same gauge as fan housing when purchased from the factory. High Temperature Construction 49 to 60 C: Requires addition of shaft cooler and high temperature grease bearings. 6 to : Above modifications plus high temperature aluminium paint. 6 to 46 : Above modifications plus modified pedestal design. Abrasion and Corrosion Resistant Alloys and Coatings Optional construction includes an abrasion resistant steel blade, backplate, scroll and side or cheek liners. Construction materials include Corten, stainless steel, Monel, aluminium, Hastelloy, and other alloys. Construction from heavier than standard gauges is available. Special corrosion resistant coatings of various types are available. ARRANGEMENTS Arrangement The usual choice for many V-belt drive applications. Impeller is overhung. Steel bearing pedestal to size 0. Size requires concrete pedestal. Consult factory for V-belt drive applications larger than 0 kw. Arrangement SI SWSI fan with integral inlet box and independent bearing pedestals. The impeller is supported between two bearings. Arrangement SI Direct coupled with a flexible coupling. A singlewidth, single-inlet fan with an integral inlet box and independent bearing pedestal and bearing/motor pedestal installed on a common base. The impeller is supported between two bearings. Arrangement 8 Direct coupled with a flexible coupling. The motor pedestal can be custom fabricated out of steel for up to kw. On larger kw units, use of standard Arr. fan with a concrete pedestal for the motor is advisable. Arrangement 9 loor mount. Similar to Arrangement with the fan base extended to mount motor in a horizontal position.

4 INLET BOXES Typical Inlet Box Dimensions Inlet Box Positions for Centrifugal ans A B To Suit an AN SIZE C D A B C D Dimensions are not to be used for construction. Dimensions are in mm unless otherwise noted. INLET AREA (m ) x x x x x x x x x x x x x x x x INLET BOX POSITIONS AND DESCRIPTIONS 4 Angular Down Intake 90 Horizontal Right Intake Angular Up Intake 80 Bottom Up Intake Angular Up Intake 0 Horizontal Left Intake Angular Down Intake 60 Top Down Intake Reference line is the Top Vertical Axis through center of fan shaft. Position of inlet box and air entry to inlet box is determined from drive side of fan. Position of inlet box is designated in degrees clockwise from Top Vertical Axis as shown. Positions to in some cases interfere seriously with floor structure. Arrangement fan with detached inlet box. Can be supplied in Arrangement 8. Arrangement fan with attached or integral inlet box. Can be supplied in Arrangement 8. Inlet Box an Inlet Box an Subbase Arrangement SI fan with integral inlet box, centrally supported impeller, independent bearings pedestals to be installed on concrete pedestals. Arrangement SI Similar to Arrangement SI except bearings pedestals and motor installed on a steel common base. Inlet Box an an Inlet Box Coupling Motor Concrete Subbase 4 TWIN CITY AN - CATALOGUE M90

5 ENGINEERING DATA Table. Material and Mechanical Specifications AN SIZE MAX. kw MIN. MAX. kw WHEEL WHEEL DESIGN SHAT MAX. WR V-BELT SHEAVE DIRECT RT DIA. DRIVE DIA. RPM DRIVE WT. ARR. BACK (kg-m (kg) HOUSING AN WT. BLADES SHROUD ) PLATE (kg) ¹ Minimum fan diameter when using maximum kw motor. Check with the factory on applications over kw. ² Maximum RPM shown are for C. or higher temperatures use Table on page 6 to derate RPM. ³ Size RT is not supplied with conventional bearings pedestal. Instead we supply channel sub-bases. The sub-base is to be mounted on concrete pedestal with steel sole plate in the field. an weights include weight of channel sub-base. Dimensions are in millimeters unless otherwise noted. Twin City an

6 ENGINEERING DATA Derating actors or High Temperature When elevated temperatures are encountered, the maximum RPM allowable as shown in Table on page must be derated according to the derating factors from Table. Standard steel construction is suitable for use in gas temperatures to 46 C. Aluminium impellers are suitable for temperatures to C only. Table. Temperature Derating actors TEMP. ( C) DERATING ACTOR STANDARD STEEL STAINLESS STEEL Performance Correction for Temperature and Altitude The performance curves in this catalogue are based on fans handling standard air at a density of.4 kilograms per cubic meter. This is equivalent to C at sea level (9.968 mm Hg barometric pressure). When specified performance is at a density different than standard, it must be converted to the equivalent standard conditions before entering the performance curves. The equivalent conditions can be calculated by using the Temperature and Altitude Density Ratios table below. Table. Temperature and Altitude Density Ratios AIR TEMP C ALTITUDE IN METRES ABOVE SEA LEVEL BAROMETRIC PRESSURE IN mm Hg (Torr) BAROMETRIC PRESSURE IN kpa Twin City an 6 TWIN CITY AN - CATALOGUE M90

7 PERORMANCE CURVES 0 8,000 6,000 RT RPM 80 RPM 0 RPM 0 LwA LwA, RPM 9 LwA kw 8.kW kw P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000 LwA 0 LwA 40 RPM 8 LwA.kW.kW kw.kw.kw.kw 0. 0 RPM 4% Pk. Eff. 6% Eff. 0.kW 0.kW 0.kW 0.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0.

8 PERORMANCE CURVES 0 8,000 RT 0 00 RPM LwA 6, RPM LwA 0 RPM kw 0kW 00 RPM kw P - an Total Pressure (in W.G.) P - an Total Pressure (Pa),000, RPM 8 LwA LwA.kW.kW kw.kw 8.kW kw RPM 0 LwA 9 LwA..kW.kW 0 LwA 0.kW RPM 4% Pk. Eff. 60 LwA 6 LwA % Eff. 0.kW 0.kW 0.kW 0.8kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. 8 TWIN CITY AN - CATALOGUE M90

9 PERORMANCE CURVES 6,000 RT 80 RPM 0 RPM LwA 00 RPM 0 LwA kw 0kW P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000,000 RPM 8.kW 40 RPM kw LwA 8 LwA 9 LwA kw.kw.kw.kw.kw kw 0 LwA.kW RPM 4% Pk. Eff LwA 6% Eff. 0.kW 0.kW 0.kW 0.kW low (m³ /sec) anvelocity Pressure (Pa). - low (CM) (in Thousands) an Efficiency Grade = EG. Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard

10 PERORMANCE CURVES 0 8,000 RT RPM 6,000 0 RPM LwA LwA 00 RPM 0 LwA kw P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000,000 RPM LwA 0kW 40 RPM 8 LwA 9 LwA.kW.kW kw.kw kw 8.kW kw kw 0 LwA.kW 00 RPM.kW % Pk. Eff. 6 LwA 64% Eff. 0.kW 0.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG. - low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. TWIN CITY AN - CATALOGUE M90

11 PERORMANCE CURVES 0,000 RT 0 0, RPM 0 8,000 0 RPM LwA LwA P - an Total Pressure (in W.G.) P - an Total Pressure (Pa) 6,000,000,000 RPM 00 RPM 40 RPM 8.kW kw.kw.kw kw kw 90kW kw kw kw 0kW kw 00 RPM 0 0 LwA LwA 8 LwA 9 LwA LwA 0 LwA. 0. 9% Pk. Eff. 0% Eff..kW.kW.kW 0.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0.

12 PERORMANCE CURVES,000 RT 00 0 RPM 0 8,000 LwA 6, RPM LwA kw kw 40 RPM LwA 90kW kw 0 LwA kw P - an Total Pressure (in W.G.) P - an Total Pressure (Pa),000,000 RPM 8 LwA 9 LwA kw 0kW kw 8.kW kw.kw.kw. 00 RPM 9% Pk. Eff. LwA 0% Eff. kw.kw.kw.kw low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. TWIN CITY AN - CATALOGUE M90

13 PERORMANCE CURVES,000 RT 0 0 8, RPM LwA 6,000 LwA 40 RPM kw 90kW kw P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000, RPM RPM LwA 8 LwA 9 LwA 0 LwA kw.kw.kw kw kw kw 0kW kw 8.kW 0 LwA.kW 6 LwA.kW RPM.kW % Pk. Eff. 60 LwA 0% Eff. 0.kW 0.kW 0.kW low (m³ /sec) anvelocity Pressure (Pa) 0 - low (CM) (in Thousands) an Efficiency Grade = EG 80. Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0.

14 PERORMANCE CURVES,000 RT RPM 0 8,000 LwA 6,000 LwA 40 RPM 60kW LwA kw kw 90kW 0 LwA kw P - an Total Pressure (in W.G.) P - an Total Pressure (Pa),000, RPM RPM 8 LwA LwA 9 LwA 8.kW kw.kw.kw kw kw 0kW kw. 0 LwA kw.kw 00 RPM 0 6 LwA.kW % Pk. Eff. 0.kW % Eff..kW 0.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. 4 TWIN CITY AN - CATALOGUE M90

15 PERORMANCE CURVES RT 6, RPM LwA LwA kw 0 LwA 90kW kw,000 kw 9 LwA P - an Total Pressure (in W.G.). P - an Total Pressure (Pa), RPM RPM LwA 8 LwA.kW.kW kw 0kW kw 8.kW kw 0 LwA kw RPM 6% Pk. Eff. 0% Eff..kW.kW.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0.

16 PERORMANCE CURVES 0 8,000 RT RPM 6,000 LwA LwA 60kW kw kw 0 LwA 90kW P - an Total Pressure (in W.G.) P - an Total Pressure (Pa),000, RPM RPM 8 LwA 9 LwA kw kw kw 0kW kw 8.kW kw LwA.kW..kW 00 RPM 0 LwA kw.kw.kw low (m³ /sec) % Pk. Eff. 0% Eff anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. 6 TWIN CITY AN - CATALOGUE M90

17 PERORMANCE CURVES,000 RT RPM 0 8,000 LwA 6,000 LwA LwA 60kW kw P - an Total Pressure (in W.G.) P - an Total Pressure (Pa),000, RPM kw RPM 90kW kw 8 LwA 9 LwA 0 LwA kw kw 0kW kw 8.kW kw. 00 RPM LwA.kW.kW RPM 6 LwA 0 LwA.kW kw 0. % Pk. Eff. 60 LwA.kW 0.kW.kW low (m³ /sec) % Eff anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0.

18 PERORMANCE CURVES RT 40 LwA RPM 0 LwA 60kW kw,000 9 LwA kw kw 90kW P - an Total Pressure (in W.G.). P - an Total Pressure (Pa), RPM kw 00 RPM LwA 8 LwA kw 0kW kw 8.kW kw.kw 0 LwA.kW 0 0 RPM 6 LwA kw % Pk. Eff..kW 0% Eff..kW.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. 8 TWIN CITY AN - CATALOGUE M90

19 PERORMANCE CURVES RT LwA RPM LwA 60kW P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000, RPM 90kW 00 RPM kw kw 8 LwA LwA 9 LwA 0 LwA kw 0kW kw 8.kW kw kw kw 0 LwA.kW 0 RPM.kW % Pk. Eff. 0% Eff..kW kw low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard

20 PERORMANCE CURVES 0 8,000 RT 660 6,000 RPM LwA LwA P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000, RPM LwA 60kW 00 RPM kw kw 8 LwA 9 LwA 0 LwA kw 0kW kw 8.kW kw 90kW kw kw 0 RPM 0 LwA.kW.kW RPM 6% Pk. Eff. 6 LwA kw.kw.kw low (m³ /sec) 0% Eff anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. TWIN CITY AN - CATALOGUE M90

21 PERORMANCE CURVES 0,000 8,000 RT 0 LwA 6,000 RPM LwA LwA 00 RPM 0 LwA P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000,000 0 RPM 00 RPM 8 LwA LwA 9 LwA 90kW kw kw kw 0kW kw 8.kW kw 60kW kw kw 0 LwA.kW RPM 0 % Pk. Eff. 6 LwA.kW % Eff..kW kw low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0.

22 PERORMANCE CURVES 0,000 RT 0,000 LwA 0 8,000 LwA 6,000 RPM LwA P - an Total Pressure (in W.G.). P - an Total Pressure (Pa),000,000 0 RPM 00 RPM LwA 00 RPM 8 LwA 9 LwA kw 8.kW kw 0 LwA kw 0kW LwA kw 90kW kw kw kw 60kW RPM 0 LwA 0. 0 % Pk. Eff. % Eff..kW.kW low (m³ /sec) anvelocity Pressure (Pa) an Efficiency Grade = EG low (CM) (in Thousands). Performance certified is for Installation Type B & D: ree or ducted inlet, ducted outlet.. Power rating (kw) does not include transmission losses.. Performance ratings do not include the effects of appurtenances (accessories). 4. The sound power level ratings shown are in decibels, referred to E- watts calculated per AMCA Standard 0.. Values shown are for inlet LwiA sound power levels for Installation Type B: ree inlet, ducted outlet.. The A-weighted sound ratings shown have been calculated per AMCA Standard 0. TWIN CITY AN - CATALOGUE M90

23 DIMENSIONAL DATA Inlet lange PCD AN SIZE BC C CC DH NH TH Twin City an

24 DIMENSIONAL DATA Arrangement, SWSI AN DB DD D A B BC BH C CC SIZE CC DE DG DH DX E EH EW E G H J K N G GA AN SIZE GC H HA HB HC HD HE H HG HH J K KA KB KL KS CL 8 CL 4 L M MA M NH x 6 x x 6 6 x x 6 6 x x 6 6 x x 8 6 x x 8 9 x x 8 9 x AN SD P Q SIZE CL 8 CL 4 SE BC998D NOTES:. CW rotation shown, CCW rotation is similar but opposite.. Standard accessories: bolted access door, housing drain, shaft seal, punched inlet & outlet flanges.. These holes are in Size 0, 00 & 0 Only. DIMENSIONS ARE NOT TO BE USED OR CONSTRUCTION. CERTIIED DRAWINGS AVAILABLE UPON REQUEST. 4 TWIN CITY AN - CATALOGUE M90

25 DIMENSIONAL DATA Arrangement, SWSI AN DB DD D A B BC BH C CC SIZE CC DE DG DH DX E EH EW E G H J K N G AN GA KS GC H HA HB HC HD HE H HG HH J K KA KB KL SIZE CL 8 CL 4 CL 8 CL 4 L M x x x x x x x x x x x x x x x x x 6 x AN SIZE MA MD M NH P Q SD CL 8 CL 4 SE TH BC9986G NOTES:. CW rotation shown, CCW rotation is similar but opposite.. Size will be supplied with channel sub-base to be mounted on concrete pedestal in the field.. Standard accessories: bolted access door, housing drain, pie split housing, shaft seal, punched inlet & outlet flanges. DIMENSIONS ARE NOT TO BE USED OR CONSTRUCTION. CERTIIED DRAWINGS AVAILABLE UPON REQUEST.

26 TYPICAL SPECIICATIONS Model RT ans shall be Model RT Radial Tip ans as manufactured by Twin City an & Blower, Minneapolis, Minnesota. PERORMANCE Performance ratings shall conform to AMCA Standard (fan efficiency grade) and (air performance). ans shall be tested in accordance with ANSI/AMCA Standard (air performance) and 00 (sound performance) in an AMCA accredited laboratory. ans shall be licensed to bear the AMCA certified ratings seal for air and fan efficiency grade (EG). HOUSING Housings shall be made of plate steel with continuously welded construction and braced with structural shapes to eliminate any resonant vibration and to provide smooth operation. Size 60 and larger housings shall have a pie-shaped split for easy impeller and shaft removal without disturbing inlet and outlet ductwork. The housing split must be fully gasketed and bolted together to prevent any leaks. langed inlet and outlet, inspection door, shaft seal and drain shall be provided as standard equipment. Bearing support members shall be fabricated of heavy steel shapes or made of concrete to insure maximum rigidity. IMPELLER Blade design shall be curved forward at the entering edge to meet air at the correct angle of entry for high efficiency and radial at the tip of the leaving edge to provide a self-cleaning characteristic. Blades shall be formed from high strength low alloy material for strength and accuracy of contour and continuously welded to the inlet shroud and backplate. A heavy fabricated steel hub shall be provided. Impellers shall be shrunk fit on the shafts and hubs must include puller holes for use in event of impeller removal. All impellers shall be statically and dynamically balanced on precision electronic machines, as well as trim balanced during the factory test run. SHAT Shafts shall be AISI 40 or 4 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least.4 times the maximum speed. BEARINGS ans shall be supplied with heavy duty, self-aligning, grease lubricated, anti-friction, pillow block type bearings selected for a minimum average bearing life (ABMA L-0) in excess of 0,000 hours at the maximum fan RPM. Bearings may be ball or roller with non-split pillow block or spherical roller bearings with split pillow block housing (bearing races not split). Where required, sleeve bearings may be used with appropriate cooling method for high carrying loads. DRIVE Motor sheaves shall be cast iron, variable pitch on applications kw and smaller, and fixed pitch on 8. kw and larger. Drives and belts shall be located external to the fan casing and rated for % of the required motor kw. INISH AND COATING The entire fan assembly, excluding the shaft, shall be thoroughly degreased and deburred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminium components shall be unpainted. ACCESSORIES When specified, accessories shall be provided by Twin City an & Blower to maintain one source responsibility. ACTORY RUN TEST All fans prior to shipment shall be completely assembled and test run as a unit at the specified operating speed or maximum RPM allowed for the particular construction type. Each impeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 4-96 "Balance Quality and Vibration Levels for ans" to an Application Category BV-, Balance Quality Grade G6.. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANTEE The manufacturer shall guarantee the workmanship and materials for at least one () year from start-up or eighteen (8) months from shipment, whichever occurs first. 6 TWIN CITY AN - CATALOGUE M90

27 Twin City an

28 INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CENTRIUGAL ANS UTILITY SETS PLENUM & PLUG ANS INLINE CENTRIUGAL ANS MIXED LOW ANS TUBEAXIAL & VANEAXIAL ANS PROPELLER WALL ANS PROPELLER ROO VENTILATORS CENTRIUGAL ROO & WALL EXHAUSTERS CEILING VENTILATORS GRAVITY VENTILATORS DUCT BLOWERS RADIAL BLADED ANS RADIAL TIP ANS HIGH EICIENCY INDUSTRIAL ANS PRESSURE BLOWERS LABORATORY EXHAUST ANS ILTERED SUPPLY ANS MANCOOLERS IBERGLASS ANS CUSTOM ANS Twin City an TWIN CITY AN & BLOWER 99 TRENTON LANE N MINNEAPOLIS, MN 44 PHONE: 6-- AX: Twin City an Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog illustrations cover the general appearance of Twin City an & Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF   CATALOG 950 AUGUST 2012 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012 RADIAL TIP FANS Model RTF Model RTF radial tip fans are of a heavy duty, rugged design,

More information

TURNING AIR INTO SOLUTIONS. HIGH EFFICIENCY INDUSTRIAL BACKWARD CURVED FANS MODEL HIB

TURNING AIR INTO SOLUTIONS. HIGH EFFICIENCY INDUSTRIAL BACKWARD CURVED FANS MODEL HIB TURNING AIR INTO SOLUTIONS. HIGH EICIENCY INDUSTRIAL BACKWARD CURVED ANS MODEL HIB CATALOGUE M0 August 4 HIGH EICIENCY ANS Overview Model HIB Model HIB fans from Twin City an & Blower employ a high-efficiency

More information

Defining Innovation. backward curved FANs

Defining Innovation. backward curved FANs Defining Innovation. high efficiency industrial backward curved FANs TYPE HIB BULLETIN 00-B May 20 HIB High-Efficiency Industrial Backward-Curved Fans Model HIB fans from Twin City Fan & Blower employ

More information

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009 Defining Innovation. radial tip FANS TYPE HRT BULLETIN 980 October 2009 HRT Radial Tip Fans Twin City Fan & Blower s Type HRT Industrial Duty Radial Tip Fan line is engineered for higher specific speeds.

More information

BACKWARD CURVED HIGH PRESSURE FANS

BACKWARD CURVED HIGH PRESSURE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BACKWARD CURVED HIH PRESSURE FANS MODEL BCS CATALOUE M400 DECEMBER 203 CENTRIFUAL FANS Model BCS Backward Curved - High Pressure The

More information

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011 Defining Innovation. high efficiency INDUSTRIAL airfoil FAN TYPE HAF BULLETIN 1150 May 2011 HAF High Efficiency Industrial Airfoil Fans Model HAF fans from Twin City Fan & Blower employ a high efficiency

More information

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS Turning Air Into Solutions. BACKWARD CURVED HIH PRESSURE FANS MODEL BCS CATALOUE M400 December 203 CentrifugalFans Model BCS Backward Curved - High Pressure The BCS fan from Twin City Fan & Blower is a

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW   CATALOG 1260 APRIL 2015 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS PRESSURE BLOWERS MODEL PBW CATALOG 120 APRIL WWW.TCF.COM PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information

Air Moving Solutions. AEROFOIL fans

Air Moving Solutions. AEROFOIL fans Air Moving Solutions. AEROOIL fans BAE SWSI BAE DWDI Catalogue M0 August 0 Airfoilans Models BAE SWSI & BAE DWDI eaturing the E-Series Impeller This catalogue features the new BAE aerofoil impeller design.

More information

BACKWARD INCLINED FANS

BACKWARD INCLINED FANS Twin City an INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BACKWARD INCLINED ANS BC-SW BC-DW CATALOGUE M00 AUGUST 0 BACKWARD INCLINED ANS Models BC SWSI & BC DWDI BC DWDI Arrangement Refer to Catalogue

More information

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS Model PBW CATALOG 120 April PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high static pressures, yet stable operation throughout

More information

MIXED FLOW FANS. Twin City Fan QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat)

MIXED FLOW FANS. Twin City Fan   QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) Twin City an INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS MIXED LOW ANS QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) CATALOGUE M0 APRIL 0 WWW.TC.COM MIXED LOW ANS Models QSL QSLR QSLSH

More information

Air Moving Solutions. AEROFOIL fans

Air Moving Solutions. AEROFOIL fans Air Moving Solutions. AEROOIL fans BAE SWSI BAE DWDI Catalogue M0 August 0 Airfoilans Models BAE SWSI & BAE DWDI eaturing the E-Series Impeller This catalogue features the new BAE aerofoil impeller design.

More information

BACKWARD INCLINED fans

BACKWARD INCLINED fans Air Moving Solutions. BACKWARD INCLINED fans BC SWSI BC DWDI Catalogue M00 August 0 BackwardInclinedans Models BC SWSI & BC DWDI This catalogue features Model BC non-overloading centrifugal fans in SWSI

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

DIrect drive exhaust & supply panel fans

DIrect drive exhaust & supply panel fans Air Moving Solutions. DIrect drive exhaust & supply panel fans MODEL BULLETIN 4800 March 2012 Direct DrivePanel ans Model panel fans are direct drive panel fans designed for low static pressures. They

More information

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN MODEL BCRFS CATALOG 4310 JUNE 2012 FILTERED SUPPLY VENTILATORS Model BCRFS Twin City

More information

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide

More information

FIXED PITCH PROPELLER FANS

FIXED PITCH PROPELLER FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS FIXED PITCH PROPELLER FANS MODEL TCWP CATALOG AX500 DECEMBER 2012 PROPELLER FANS Model TCWP Fixed Pitch Heavy-Duty Construction Twin

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS The Industrial Choice. TURBO PRESSURE BLOWERS Models HPBA / HPBS CATALOG 914 February Turbo Pressure Blowers Models HPBA HPBS The HPB series of fans are low volume, high-pressure blowers designed for stable

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose

More information

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS Model TCPE CATALOG 4800 February 2017 PANEL FANS Overview TCPE TCPE panel fans are direct drive panel fans designed for low static pressures.

More information

turbo pressure blowers

turbo pressure blowers efining Innovation. turbo pressure blowers TYPE TBNA TBNS BULLETIN May TBN Turbo Pressure Blowers Introduction The TBN series of fans are low volume, high-pressure blowers designed for stable operation

More information

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN TURNING AIR INTO SOLUTIONS. COMPACT PLENUM S ECLFN ECLQN CATALOG 456 July 2017 PLENUM S Overview ECLFN I ECLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated or factory-built

More information

Air Moving Solutions. MODULAR plenum fans

Air Moving Solutions. MODULAR plenum fans Air Moving Solutions. MODULAR plenum fans MPQN MPQS CATALOG 490 March 2012 PlenumFans Models MPQN MPQS The MPQN and MPQS offer many of the same advantages of the venerable EPQN plenum fan. The MPQN and

More information

TURNING AIR INTO SOLUTIONS. INDUSTRIAL FANS RBA RBO RBR RBW RBP

TURNING AIR INTO SOLUTIONS. INDUSTRIAL FANS RBA RBO RBR RBW RBP TURNING AIR INTO SOLUTIONS. INUSTRIAL S RBA RBO RBR RBW RBP CATALOG 902 November 2017 INUSTRIAL S Overview RBA I RBO I RBR I RBW I RBP The Radial Bladed Industrial Fans are designed for applications with

More information

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS CATALOGUE M1250 April 2015 TURBO PRESSURE BLOWERS Overview TBNA I TBNS The TBN series of fans are low volume, high-pressure blowers designed

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INUSTRIAL PROCESS AN COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBNA TBNS CATALOG 12 AUGUST 14 TURBO PRESSURE BLOWERS Overview TBNA I TBNS The TBN series of fans are low volume,

More information

Cyclone Custom Centrifugal Fans

Cyclone Custom Centrifugal Fans Cyclone Custom Centrifugal Fans A L P H A I R Custom Engineered Centrifugal Fans ALPHAIR s line of custom engineered centrifugal fans is ideally suited for applications that involve moving air at higher

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX510-A October 2009 ADJUSTABLE PITCH PROPELLER FANS TYPE TCWPX TCWPX Adjustable Pitch Propeller Fans Sizes 24" 48" Direct Drive Belt Driven Heavy-Duty Construction Twin

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 370 January 2007 AIRFOIL FANS TYPE BAE SWSI and DWDI BAE SWSI and DWDI Airfoil Fans Featuring the E-Series Wheel This catalog features the new BAE airfoil wheel design.

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

Air Moving Solutions. AIRFOIL fans

Air Moving Solutions. AIRFOIL fans Air Moving Solutions. AIRFOIL fans BAE SWSI BAE DWDI CATALOG 370 December 2012 AirfoilFans Models BAE SWSI & BAE DWDI Featuring the E-Series Wheel This catalog features the new BAE airfoil wheel design.

More information

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED ROOF VENTILATORS Models BSHD / BSHB CATALOG 632 November 12 Hooded Roof Ventilators Models BSHD BSHB Aerovent Low Profile Hooded Roof Ventilators

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32

Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32 efining Innovation. INUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32 BULLETIN 902 June 2011 RB Industrial Fans Class 22 & 32 Industrial Fans for Efficiency, ependability, and Versatility The Series

More information

CAST ALUMINUM PRESSURE BLOWERS

CAST ALUMINUM PRESSURE BLOWERS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CAST ALUMINUM PRESSURE BLOWERS TPD TPB CATALOG 820 JANUARY 2013 PRESSURE BLOWERS Models TPD TPB Twin City Fan & Blower s Cast Aluminum

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

Good Enough Never Is. Plug Fan SERIES 12

Good Enough Never Is. Plug Fan SERIES 12 Plug Fan SERIES 12 Good Enough Never Is The Hartzell Difference Combine Hartzell QUALITY with your PRODUCT for a BETTER CHOICE for your customers! GOOD ENOUGH NEVER IS. Hartzell Air Movement is the industrial

More information

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP The Industrial Choice. WALL S DIRECT DRIVE & BELT DRIVEN Models BSDDP / BSBP CATALOG 172 June 15 Propeller Wall Fans Models BSDDP BSBP Aerovent BSDDP and BSBP Propeller Wall Fans are specifically designed

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio Vaneaxial Fans Series 25 Series 53 Series 53C Series 54 Series 55 BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 February 2008 Index Model Code Explanation...Page

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

Defining Innovation. DIRECT DRIVE backward inclined fans TYPE TCBI

Defining Innovation. DIRECT DRIVE backward inclined fans TYPE TCBI Defining Innovation. DIRET DRIVE backward inclined fans For dust collectors TYPE TBI BUETIN 330 February 2011 Direct Drive Backward Inclined Fans Twin ity Fan & Blower offers the type TBI Backward Inclined

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 300-F January 2009 BACWARD INCLINED FANS TYPE BC SWSI & DWDI BC SWSI & DWDI Backward Inclined Fans This catalog features type BC non-overloading centrifugal fans in SWSI

More information

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB

Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB Turning Air Into Solutions. CAST ALUMINUM PRESSURE BLOWERS MODEL TPD MODEL TPB CATALOG 820 January 2013 PressureBlowers Models TPD TPB Twin City Fan & Blower s Cast Aluminum Pressure Blowers are the perfect

More information

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The Industrial Choice. INDUSTRIAL FANS MHO / MHR / MHA / MHW / MHP CLASS 22 & 32

The Industrial Choice. INDUSTRIAL FANS MHO / MHR / MHA / MHW / MHP CLASS 22 & 32 The Industrial Choice. INUSTRIAL S HO / HR / / HW / HP CLASS 22 & 32 CATALOG 710 February 2013 Industrial Fans odels - Class 22 & 32 HO I HR I I HW I HP The H Series Industrial Fans manufactured by Aerovent

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements SURGE LIMITING BULLETIN 485 APRIL, 2017 PB FANS Designed for high pressure, low flow applications with stringent job process requirements Capacities to 30,000 CFM Static pressures to 180 WG Temperatures

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

HIGH VELOCITY FUME EXHAUST FANS

HIGH VELOCITY FUME EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS HIGH VELOCITY FUME EXHAUST S TFE QFE CATALOG 1500 MAY 2012 FUME EXHAUST S Models TFE & QFE Inline Fume Exhaust Fans Twin City Fan & Blower

More information

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: HDBI BLOWERS OEM and Industrial Air Handling Specialist BACKWARD INCLINED CLASS II CLASS III CLASS IV 797 Snider Road, Mason, OH 45040-915 Telephone: 51-57-000 Visit us at www.cincinnatifan.com for more

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

Turning Air Into Solutions. CAST IRON BLOWERS MODEL CIW

Turning Air Into Solutions. CAST IRON BLOWERS MODEL CIW Turning ir Into Solutions. CST IRON BLOWERS OEL CIW CTLOG 850 ay 2012 CastIronPressureBlowers odel CIW Twin City Fan & Blower s CIW Cast Iron Pressure Blowers are the perfect choice for providing low volume,

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

Industrial Mini Vent Sets

Industrial Mini Vent Sets Industrial Mini Vent Sets FRP Construction M I N I S E R I E S and Impellers Volume Range shut off up to 4000 (1888 l/sec) Static pressures up to 19 W.G. (4719 Pa) Industrial and Commercial Applications

More information

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone:

CPAF SERIES CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III Snider Road, Mason, OH Telephone: OEM and Industrial Air Handling Specialist SERIES CPAF CENTRIFUGAL PLUG FANS CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group VERANTIS Environmental Solutions Group FRP Fans: CMHB Series 6-8-10 Performance and Technical Information Bulletin 11-6 Rev May 2013 VERANTIS Environmental Solutions Group Verantis Environmental Solutions

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 MARCH, 2014 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

ceiling & inline/cabinet ventilators

ceiling & inline/cabinet ventilators Air Moving Solutions. ceiling & inline/cabinet ventilators T-Series ( T TL ) CATALOG 4600 March 2012 Ceiling&InlineVentilators T-Series T TL Twin City Fan & Blower s T Series Ceiling and TL Series Inline/Cabinet

More information

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications... Industrial Material Handler Page Introduction.......................................... 2 Information.......................................... 3-5 Specifications MH Specifications.....................................

More information

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index www.sheldonsengineering.com AIR HANDLING-RADIAL BLADE CENTRIFUGAL FAN 9000 XB GENERAL The centrifugal fan shall be designed and manufactured

More information

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index AIR HANDLING-RADIAL BLADE CENTRIFUGAL FAN XB GENERAL The centrifugal fan shall be designed and manufactured by Sheldons Engineering to ensure

More information

CEILING & INLINE/CABINET VENTILATORS

CEILING & INLINE/CABINET VENTILATORS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 MARCH 2018 CEILING & INLINE VENTILATORS OVERVIEW T I TL T-Series

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series

TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS. T-Series TL-Series TURNING AIR INTO SOLUTIONS. CEILING & INLINE/CABINET VENTILATORS T-Series TL-Series CATALOG 4600 March 2018 CEILING & INLINE VENTILATORS Overview T I TL Twin City Fan & Blower s T-Series Ceiling and TL-Series

More information

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Bulletin 8510-4 May 2000 Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Description Index Series 8500 Centrifugal Swingout Fans The Series 8500 Centrifugal

More information

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index www.sheldonsengineering.com SQUARE BODY RADIAL BLADE CENTRIFUGAL FAN D6900 GENERAL SPECIFICATION. The centrifugal fan shall be designed and

More information

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted The Industrial Choice. Model FSWB Wall Mounted Model FSR Roof Mounted FILTERED AIR SUPPLY FANS Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF CATALOG 664 June 2013 Filtered Air Supply Fans Roof

More information

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL Fiberglass Axial Flow Fans Series 28 Series 28B Series 29 Series 29B Series 34 Series Series V BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 46 Bulletin A-39-N

More information

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC TURNING AIR INTO SOLUTIONS. AIR KITS Model FC CATALOG 150 June 2017 AIR KITS Overview FC Wheel Construction Air kit wheels are designed for speeds up to 7,000 ft/min. at 70 F. The blades are die-formed

More information

to meet the updated test procedures outlined in the 1974 AMCA test code.

to meet the updated test procedures outlined in the 1974 AMCA test code. Sheldons Engineering is a long-standing member of AMCA The Air Movement and Control Association which acts as an independent association for fan manufacturers. As you may be aware, Sheldons Engineering

More information

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK CENTRIFUGAL WALL EXHAUSTERS Direct and Belt Driven Models VWDK and VWBK DESIGNED AND ENGINEERED TO MEET INDUSTRY NEEDS The Carnes Company centrifugal wall

More information

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application

SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application CAT.NO. 120-97 SARAVEL CENTRIFUGAL FANS For Airconditioning & Industrial Application TABLE OF CONTENTS Introduction......3 Selection Examples......4-5 Correction Factors......6 Rating Tables.........7-17

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

Air Moving Solutions. axifan adjustable blade vaneaxial fans

Air Moving Solutions. axifan adjustable blade vaneaxial fans Air Moving Solutions. axifan adjustable blade vaneaxial fans MODEL TCVX CATALOG AX300 December 2012 VaneaxialFans Model TCVX The heart of the TCVX AXIFAN lies in its wheel. The manually adjustable blades

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 SEPTEMBER, 2011 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES COMEFRI USA: Manufacturing and Warehouse facilities in Hopkinsville, KY. Total facility: 125,000 sq.ft. Producing centrifugal fans

More information

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7 CONTENTS Page Adjustable Axial Pitch Flow Fans 3 Dimensions 4 AP056 Performance Curves 5 AP056 Sound Performance 6 AP063 Performance Curves 7 AP063 Sound Performance 8 AP071Performance Curves 9 AP071 Sound

More information

AIR KITS SINGLE AND DOUBLE. SINGLE AIR KITS Capacities to 84,000 CFM Pressures to 6 WG Temperatures to 1000 F.

AIR KITS SINGLE AND DOUBLE. SINGLE AIR KITS Capacities to 84,000 CFM Pressures to 6 WG Temperatures to 1000 F. ULLETIN 631 OCTOER, 2009 SINGLE AND DOULE AIR KITS DOULE AIR KITS Capacities to,000 Pressures to 6 WG Temperatures to 0. SINGLE AIR KITS Capacities to 84,000 Pressures to 6 WG Temperatures to 0. THE NEW

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information