Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32

Size: px
Start display at page:

Download "Defining Innovation. INDUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32"

Transcription

1 efining Innovation. INUSTRIAL FANS TYPE RBO RBR RBA RBW RBP - CLASS 22 & 32 BULLETIN 902 June 2011

2 RB Industrial Fans Class 22 & 32 Industrial Fans for Efficiency, ependability, and Versatility The Series 900 Industrial Fans manufactured by Twin City Fan & Blower are well suited for installations involving exhaust, material conveying, pollution control, air circulation, and a variety of other industrial applications. The typical performance characteristics for different wheels offered in Series 900 fans are illustrated below. It should be noted that all wheels essentially have overloading characteristic type brake horsepower curves; however, type RBA wheels have this to a lesser degree than other types. While the general pressure characteristic curve is similar for all Series 900 wheels, the RBA type wheel is considerably more efficient than other Series 900 wheels. Therefore, the RBA wheel is the first choice where brake horsepower savings are important, but the RBA wheel is limited to handling relatively clean air or gases. Efficiency is critical in most applications, and it is important that the fan size is selected so that it will operate at or near its maximum efficiency point. This is particularly important with the units that have lower efficiency in general, such as the RBO and RBW wheels. Typical Performance Characteristic Curves for Industrial Wheels RBO, RBR RBA RBW % STATIC PRESSURE % BRAKE HORSEPOWER % STATIC PRESSURE % BRAKE HORSEPOWER % STATIC PRESSURE % BRAKE HORSEPOWER CFM IN % WOV CFM IN % WOV CFM IN % WOV RB Series Availability Size Wheel Type Rotatable Reversible Class 22 Class 32 housing discharge rotation Arrangements Arrangements 905 RBO YES YES 1,8,9A,9B, RBO YES YES 1,4,8,9A,9B,9F,10 RBA, RBW YES NO 1,4,8,9A,9B,9F,10 RBO YES YES 1,4,8,9A,9B,9F,10 1,4,8,9,9F RBA, RBW YES NO 1,4,8,9A,9B,9F,10 1,4,8,9,9F RBP YES NO 1,9,9F RBO*, RBA, RBW NO NO 1,8,9A,9B,9F,10 1,8,9,9F RBP NO NO 1,9,9F 929 RBO*, RBA, RBW NO NO 1,8,9A,9B,9F 1,8,9,9F RBO*, RBA, RBW NO NO 1,8,9,9F 1,8,9,9F RBO, RBA, RBW NO NO 1,8,9,9F * Note: RBR is standard on size 926 and larger Class 32 fans. Series 900 fan housings are constructed in all usual arrangements and conform to AMCA Standard (rive Arrangements for Centrifugal Fans). The fan sizes and wheel diameters conform to AMCA Standard (Sizes for Industrial Centrifugal Fans). AMCA does not have a standard for industrial fans designating class of operation. Twin City Fan & Blower offers three basic categories, based on performance, of industrial fans. Two of the categories are shown in this bulletin: 1. Class 22 suitable for applications involving performance to approximately 22" SP; and 2. Class 32 for performance to 32" SP. Performances shown in the tables on pages 11 through 29 are shown in regular face type to indicate Class 22 fans and in bold face type to indicate Class 32 fans. A separate supplemental bulletin (Bulletin 911) shows the third category: Class 45 high pressure fans capable of reaching performance of approximately 45" SP. Twin City Fan & Blower certifies that the Series 900 type RBO/RBR/RBA/ RBW fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. 2 Twin City Bulletin 902

3 Wheel esign Twin City Fan & Blower offers a complete series of wheels to meet the needs of most industrial process and material handling applications. Each wheel is statically and dynamically balanced on electronic RBW Industrial Radial Backplate Wool Wheel: The RBW wheel is constructed to prevent paper shreddings, threads from buffing system exhaust, and other similar matter from hanging up on and wrapping around the spiders and blades. Applications include long, stringy or fibrous materials. RBO Industrial Radial Paddle Wheel: The open type radial paddle wheel design is extremely rugged using heavygauge steel components which are jig assembled for accuracy and consistency. All wheels are welded with care to insure the maximum in strength and reliability. RBO wheels are suitable for general handling of coarse, sticky, heavy, and/or abrasive materials. equipment prior to being assembled in the fan. In addition, each unit is run at or near operating speed after assembly and the balance is fine-tuned as a complete assembly. RBR Industrial Radial Paddle Wheel: The RBR wheel is similar to the RBO, with the addition of end rings. RBR construction is standard on size 926 and larger Class 32 fans. RBR wheels are suitable for general handling of coarse, sticky, heavy, and/or abrasive materials. RBA Industrial Radial Air Handling Wheel: The RBA wheel is a more efficient type of wheel and is used when handling relatively clean air, fumes, vapor exhaust, and air with a light contaminant. The wheel is constructed with heavy-gauge blades welded to both backplate and front ring. RBP Industrial Radial Paper Handling Wheel: This modified RBW wheel features trapezoidal gussets for the extra rugged construction necessary when handling corrugated paper trims, fibrous material, metal trim, and other high impact loading material. A paper deflector cone over the face of the hub helps prevent wrapping of paper around the hub or leading edge of the blades. All RBP fans are supplied with bearing stop blocks and a relieved inlet transition. The relieved inlet transition smooths the flow of paper trim and similar material through the fan. Breaker tabs are offered as an option on the relieved inlet transition to assist in the breakup of material. ue to the nature of the applications, RBP Class 32 construction is limited to 22" SP and RBP Class 45 construction is limited to 32" SP. Use RBW performance tables for RBP fans. The RBP fan is not AMCA licensed. Rotatable and Reversible Configuration The table on page 2 identifies fans that are rotatable or reversible. A fan available in a rotatable configuration indicates that the fan can be rotated in the field to any of the standard discharge locations. A fan available in a reversible configuration indicates that the wheel rotation can be changed in the field from a clockwise to a counterclockwise direction or vice versa. This is possible only on rotatable housings and requires the wheel housing to be removed and reversed. Consult the factory before reversing a fan. See the chart on page 7 for specific configurations and their designations. 3 Twin City Bulletin 902

4 Accessories Access oors Bolted and quick-opening access doors are available for easy access to the fan interior for inspection or cleaning. All access doors are gasketed and are constructed with either evenly-spaced studs or heavy duty hinges and handle-type nuts which require no tools to open. Raised bolted access doors are available for use where insulation is being applied to the outside of the fan. Bolted Access oor Inlet Bell On installations with an open inlet (no ductwork at the inlet of the fan), a streamlining inlet bell is required to achieve the catalog performance. Raised Bolted Access oor Outlet ampers ue to the performance characteristics of industrial fans, a damper on the outlet of the fan is a very efficient way to control volume. An outlet damper can be used to reduce the power consumption of a fan operating at high temperatures or a fan operating in low density gas streams. uring a cold startup, the outlet damper begins in a closed position and is opened gradually as the fan reaches operating temperature. This allows for the use of a smaller motor sufficient to handle the duty at higher temperatures. Twin City Fan & Blower offers two basic styles of outlet dampers: Type 1 is made of single surface blades suitable for clean air applications, pressures to 25" SP and temperatures to 300 F; Type 2 has double surface airfoil blades for abrasive type applications, pressures to 40" SP and temperatures to 800 F. Both types of dampers are available with opposed or parallel blades and can be manually operated or set up for automatic operation. Inlet Bell Quick-Opening Access oor Inlet Vanes For reduced flow situations with relatively clean air, inlet vane type dampers are available to maintain fan efficiency. The inlet vanes are external type attached to the inlet of the fan. Standard construction inlet vanes are suitable in applications up to 300 F. High temperature inlet vanes are also available for temperatures up to 600 F. Outlet amper Inlet Vanes 4 Twin City Bulletin 902

5 Accessories Inlet Boxes An inlet box is designed to minimize pressure drop and airflow losses. Inlet boxes are recommended for applications where uniform flow is difficult to obtain due to limited space or where the air must enter the fan at an angle. Inlet boxes can be either detachable or integral to the fan. This option is available with an inlet box damper to provide increased airflow control. Inlet Box Shaft Coolers Where high temperatures are encountered, the aluminum shaft cooler is recommended for dissipating heat and protecting bearings from the high temperature atmosphere. Shaft Seals The standard shaft seal is a non-asbestos type, sandwiched between two plates and the fan housing, providing a seal for most materials being handled. A variety of special seals, including mechanical type stuffing boxes, is available for gas-tight applications requiring more positive protection. Shaft Cooler rains A pipe coupling can be welded to the lowest point in the housing scroll to allow wash water or condensation to drain. Spark Resistant Construction Three fan constructions are available for spark resistance. The materials used in the construction of these fans minimize the potential of sparks being generated by striking or rubbing components within the airstream. Type A All parts of the fan in contact with the air or gas being handled are made of nonferrous material. (Aluminum wheel construction is limited to 250 F.) Type B The fan has an entirely nonferrous wheel and nonferrous ring around the opening through which the shaft passes. (Aluminum wheel construction is limited to 250 F.) Type C The fan is constructed so that a shift of the wheel or shaft will not permit two ferrous parts of the fan to rub or strike. In applications where aluminum is not suitable, wheels constructed of monel can be furnished for temperatures up to 1000 F. Notes: 1. The user must electrically ground the fan. 2. Standard spark resistant alloy is aluminum. 3. Bearings must not be placed in the air or gas stream. Shaft Seal Other Accessories A large number of other appurtenances and accessories is available from Twin City Fan & Blower, including: Belt guards standard and OS type Split housings Shaft and bearing guards Couplings and coupling guards Wheel liners Scroll liners Weather covers Inlet and outlet screen Special material construction (stainless steel, Monel, etc.) Special coatings and finishes Insulation pins Abrasion resistant construction Common bases with and without isolation Breaker tabs are offered on Series 900 RBP fans as an option on the relieved inlet transition. These tabs assist in the breakup of material as it enters the fan. 5 Twin City Bulletin 902

6 Arrangements The Series 900 fan housings are constructed of heavy-gauge steel with side plates continuously welded to the scroll. Housings are securely braced to prevent vibration and pulsation. Wheel removal is accomplished through the large opening provided at the inlet side of the housing. Lifting lugs are standard on all units. Arrangement 1 Arrangement 1 fans are available in either direct drive (see Arrangement 8 below), or belt driven installations. The belt driven configuration allows the motor to be mounted in any of the four standard motor positions shown on page 7. The choice of a belt driven installation provides greater performance flexibility with the use of belts and sheaves of differing sizes. Arrangement 8 Arrangement 8 fans use a fan shaft and motor direct coupled via a flexible coupling. The integral motor subbase is fabricated of heavy gauge steel and securely reinforced for rigidity. Twin City Fan & Blower can supply wheels in a variety of diameters and differing widths to give the greatest efficiency for any given application. If desired, an Arrangement 1 fan can be set up for direct drive. This requires a concrete motor pedestal to be built in the field. Arrangement 9 Arrangement 9 fans include a motor slide base mounted on the side of the motor pedestal. The motor and drive can be installed at the factory or field installed. Class 22 fans up to size 929 are offered in Arrangements 9A (shorter pedestal for small motors) and 9B (longer pedestals for larger motors). Maximum motor frame sizes for Arrangement 9A and 9B are listed in the table on page 7. Unless otherwise specified, the motor will be installed on the left (L) side of the pedestal on CW fans and on the right (R) side on CCW fans. Arrangement 9F Arrangement 9F (floor mount) fans are recommended when a packaged unit is desired, but required motors are too large to be mounted on the side of the bearing pedestal. In this arrangement, the base is extended to facilitate motor mounting in a horizontal position similar to an Arrangement 1 fan. This arrangement is preferred over Arrangement 9 when larger horsepower motors are being employed. Unless otherwise specified, the motor will be installed on the left (L) side of the pedestal on CW fans and on the right (R) side on CCW fans. Arrangement 9F requires a separate subbase when vibration isolation is required. Arrangement 10 Arrangement 10 fans are suitable for roof or outdoor installations. A weather cover, as shown, provides complete weather protection for motor, shaft, bearings, and drives. This arrangement is limited to Class 22, sizes 905 through 919. Maximum motor sizes allowable in this arrangement are listed in the table on page 7. Larger fan sizes in this arrangement, or larger motor sizes for smaller fans, may be available on special request from the factory. All usual accessories are available in this arrangement. 6 Twin City Bulletin 902

7 Standard Configurations esignations for Rotation and ischarge Clockwise Clockwise Clockwise Clockwise Counterclockwise Counterclockwise Counterclockwise Counterclockwise Upblast Top Angular Up Top Horizontal Top Angular own Upblast Top Angular Up Top Horizontal Top Angular own CW 360 CW45 CW90 CW135 CCW360 CCW45 CCW90 CCW135 Clockwise Clockwise Clockwise Clockwise Counterclockwise Counterclockwise Counterclockwise Counterclockwise ownblast Bottom Angular own Bottom Horizontal Bottom Angular Up ownblast Bottom Angular own Bottom Horizontal Bottom Angular Up CW 180 CW225 CW270 CW315 CCW180 CCW225 CCW270 CCW315 irection of rotation is determined from the drive side of the fan. On single inlet fans, the drive side is always considered the side opposite the fan inlet. irection of discharge is determined in accordance with the diagrams shown above. Angle of discharge references the horizontal axis of the fan, and is designated in degrees above or below that reference axis. On fans inverted for ceiling suspension or side-wall mounting, the direction of rotation and discharge is determined when the fan is resting on the floor. Maximum Motor Frame Size Size Class 22 Class 32 9A 9B 9 9F F T T 215T 215T 184T T 256T 256T 215T T 256T 284T 256T 256T 286T T 286T 324T 256T 286T 326T T 286T 324T 286T 286T 326T T 326T 326T 286T 326T 365T T 365T 365T 326T 365T 405T T 365T 365T 365T 405T T 365T 365T 365T 445T T 405T 405T 405T 445T T 405T 444T 405T 445T T 445T 405T 445T T 445T 405T 445T T 445T 405T 445T T 445T 405T 445T T 445T 405T 445T T 445T T 445T Motor Positions The drawing above illustrates motor position standards for Arrangement 1 fans. The location of the motor is determined by facing the drive side of the fan and designating the motor position by letters W, X, Y, or Z. 7 Twin City Bulletin 902

8 Engineering ata High Temperature Construction Requirements AVAILABLE TEMPERATURE ( F) TYPE OF BEARING LUBRICATION OTR REQUIREMENTS ARRANGEMENTS Arr. 1, 4, 8, 9 & 10; 20 F To Ball or Roller Grease Standard Fan Arr. 4 limited +300 F to 180 F. Shaft Cooler, Shaft Seal, 300 F To High Temp. Arr. 1, 8, 9, Ball or Roller Expansion and 500 F Grease and 10* Non-Expansion Bearings Arr. 1, 8, 9, & 10*; High Temp. Aluminum Paint, 500 F To High Temp. (Arr. 9 & 10 limited Ball or Roller Shaft Cooler, Shaft Seal, Expansion 800 F Grease to 600 F unless and Non-Expansion Bearings fan is insulated.) 800 F To Ball or Roller High Temp. Consult Factory 1000 F Grease *Arrangement 10 includes insulated pedestal erating Factors for High Temperature erating Factor TEMP. RBO (22,32); RBA (22); (ºF) RBW (22,32) RBA (32); RBP (32) Std Steel Stainless 50 KSI Stainless When elevated temperatures are encountered, maximum RPM allowable as shown below must be derated according to the values given in the table. Standard steel construction is suitable for use in gas temperatures up to 800 F. Aluminum wheels are suitable for temperatures up to 250 F only. For higher maximum RPM or elevated temperatures consult factory. Maximum RPM, Wheel Weights, & WR 2 (Moment of Inertia) Type RBO/RBR Type RBW Type RBA Fan WEL WR 2 MAX. WEL WR 2 MAX. WEL WR 2 MAX. WT. (lb) (LB-FT 2 ) RPM WT. (lb) (LB-FT 2 ) RPM WT. (lb) (LB-FT 2 ) RPM CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL 32 CL 22 CL Twin City Bulletin 902

9 Engineering ata Material Specifications Housing Housing RBO/RBR Wheel RBW Wheel RBA Wheel Shaft BRG. COE Fan CLASS 22 CLASS 32 (NOTE 2) (NOTE 2) (NOTE 2) diameter (NOTE 1) Size Side Side CL 22 R CL 32 R Back CL 22 CL 32 Back Wheel CL 22 CL 32 CL CL CL CL Sides Scroll Sides Scroll Plates Plates Blade Rim Blade Rim Plate Blade Blade Plate Cone Blade Blade GA. 10 GA. 12 GA. 10 GA GA. 10 GA. 12 GA. 10 GA GA. 7 GA. 10 GA. 12 GA GA. 10 GA. 12 GA. 10 GA GA. 7 GA. 10 GA. 10 GA GA. 10 GA. 10 GA. 7 GA. 7 GA. 7 GA. 7 GA GA. 7 GA. 7 GA RB GA. 10 GA. 10 GA. 7 GA. 7 GA. 7 GA. 7 GA GA. 7 GA. 7 GA RB GA. 10 GA. 10 GA. 7 GA. 7 GA. 7 GA GA. 7 GA. 7 GA RB GA. 10 GA. 10 GA. 7 GA. 7 GA. 7 GA GA. 7 GA RB GA. 10 GA. 10 GA. 7 GA. 7 GA. 7 GA GA. 7 GA RB RB GA. 7 GA. 10 GA. 7 GA. 7 GA. 7 GA GA. 7 GA RB RB GA. 7 GA. 7 GA GA GA. 7 GA RB RB GA. 7 GA. 7 GA GA. 7 GA RB RB GA. 7 GA. 7 GA GA RB RB GA GA GA RB RB GA GA RB SRB GA GA SRB SRB GA SRB SRB SRB SRB SRB SRB NOTES: imensions are in inches unless otherwise noted. 1. BEARINGS COES: SB Standard-uty Ball such as odge SCAH Heavy-uty Ball such as odge SCMAH or Sealmaster MP Series RB Roller Bearing such as odge S2000 or SKF SYR Series SRB Split Roller Ball such as SKF SAF225 or Linkbelt PLB6800 Series 2. Gauges listed are for standard steel wheel; steel alloy will vary with size and class. 3. Bearing selection is made on the basis of L-10 bearing life to be in no case less than 40,000 hours minimum or L-50 life of 200,000 hours. Bare Fan Weights (lb) arrangements Fan CLASS 22 CLASS A, 9B 9F , 9F NOTE: Weights are less motor, drives and accessories 9 Twin City Bulletin 902

10 Inlet Boxes Typical Inlet Box imensions C B E A F C INLET A B CL CL E AREA F (FT 2 ) x x x x x x x x x x x x x x x x x x Wheel iameter: 8.75" Inlet Area: 0.14 ft2 Outlet Area: 0.15 ft 2 RBO 905 Tip Speed (FPM): 2.29 x RPM Inlet iameter: 5" O.. Outlet imension: 4 1 2" x 4 7 8" 0.5" SP 1" SP 1.5" SP 2" SP 2.5" SP 3" SP 3.5" SP 4" SP 4.5" SP 5" SP 5.5" SP " SP 6.5" SP 7" SP 7.5" SP 8" SP 8.5" SP 9" SP 9.5" SP 10" SP 10.5" SP 11" SP MAXIMUM RPM: 5296 Selections above 4000 RPM not recommended. Consult factory. Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

11 907 Wheel iameter: 12.25" Inlet Area: 0.26 ft2 Outlet Area: 0.27 ft 2 RBO 907 Tip Speed (FPM): 3.21 x RPM Inlet iameter: 7" O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 5296 Selections above 4000 RPM not recommended. Consult factory. RBA MAXIMUM RPM: CLASS 22 = 5273 Selections above 4000 RPM not recommended. Consult factory. RBW MAXIMUM RPM: CLASS 22 = 5457 Selections above 4000 RPM not recommended. Consult factory. Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

12 909 Wheel iameter: " Inlet Area: 0.43 ft2 Outlet Area: 0.44 ft 2 RBO 909 Tip Speed (FPM): 4.09 x RPM Inlet iameter: 9" O.. Outlet imension: " x 8 5 8" MAXIMUM RPM: CLASS 22 = 4156 Selections above 4000 RPM not recommended. Consult factory. RBA MAXIMUM RPM: CLASS 22 = 4134 Selections above 4000 RPM not recommended. Consult factory. RBW MAXIMUM RPM: CLASS 22 = 4192 Selections above 4000 RPM not recommended. Consult factory. Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

13 911 Wheel iameter: " Inlet Area: 0.64 ft2 Outlet Area: 0.66 ft 2 RBO 911 Tip Speed (FPM): 5.01 x RPM Inlet iameter: 11" O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 3283 CLASS 32 = 3844 RBA MAXIMUM RPM: CLASS 22 = 3373 CLASS 32 = 4000 RBW MAXIMUM RPM: CLASS 22 = 3495 CLASS 32 = 4016 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

14 913 Wheel iameter: " Inlet Area: 0.87 ft2 Outlet Area: 0.93 ft 2 RBO 913 Tip Speed (FPM): 5.92 x RPM Inlet iameter: 13" O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 2822 CLASS 32 = 3378 RBA MAXIMUM RPM: CLASS 22 = 2812 CLASS 32 = 3337 RBW MAXIMUM RPM: CLASS 22 = 2922 CLASS 32 = 3373 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

15 915 Wheel iameter: " Inlet Area: 1.17 ft2 Outlet Area: 1.24 ft 2 RBO 915 Tip Speed (FPM): 6.84 x RPM Inlet iameter: 15" O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 2485 CLASS 32 = 2923 RBA MAXIMUM RPM: CLASS 22 = 2521 CLASS 32 = 2910 RBW MAXIMUM RPM: CLASS 22= 2531 CLASS 32 = 2921 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

16 917 Wheel iameter: " Inlet Area: 1.58 ft2 Outlet Area: 1.59 ft 2 RBO 917 Tip Speed (FPM): 7.76 x RPM Inlet iameter: " O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 2191 CLASS 32 = 2577 RBA MAXIMUM RPM: CLASS 22 = 2147 CLASS 32 = 2566 RBW MAXIMUM RPM: CLASS 22 = 2232 CLASS 32 = 2576 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

17 919 Wheel iameter: 33" Inlet Area: 1.97 ft2 Outlet Area: 1.97 ft 2 RBO 919 Tip Speed (FPM): 8.64 x RPM Inlet iameter: " O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 1951 CLASS 32 = 2315 RBA MAXIMUM RPM: CLASS 22 = 1928 CLASS 32 = 2304 RBW MAXIMUM RPM: CLASS 22= 2004 CLASS 32 = 2313 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

18 921 Wheel iameter: 36.5" Inlet Area: 2.40 ft2 Outlet Area: 2.41 ft 2 RBO 921 Tip Speed (FPM): 9.56 x RPM Inlet iameter: " O.. Outlet imension: " x 20" MAXIMUM RPM: CLASS 22 =1778 CLASS 32 = 2092 RBA MAXIMUM RPM: CLASS 22 = 1733 CLASS 32 = 2083 RBW MAXIMUM RPM: CLASS 22 = 1791 CLASS 32 = 2091 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

19 923 Wheel iameter: 40" Inlet Area: 2.88 ft2 Outlet Area: 2.90 ft 2 RBO 923 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x 22" MAXIMUM RPM: CLASS 22 = 1623 CLASS 32 = 1910 RBA MAXIMUM RPM: CLASS 22 = 1581 CLASS 32 = 1905 RBW MAXIMUM RPM: CLASS 22 =1635 CLASS 32 = 1912 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

20 926 Wheel iameter: " Inlet Area: 3.68 ft2 Outlet Area: 3.69 ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " RBO/R 926 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 1439 CLASS 32 = 1693 RBA MAXIMUM RPM: CLASS 22 = 1402 CLASS 32 = 1689 RBW MAXIMUM RPM: CLASS 22 = 1449 CLASS 32 = 1696 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

21 929 Wheel iameter: 50.5" Inlet Area: 4.58 ft2 Outlet Area: 4.62 ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " RBO/R 929 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 1286 CLASS 32 = 1513 RBA MAXIMUM RPM: CLASS 22= 1253 CLASS 32 = 1509 RBW MAXIMUM RPM: CLASS 22 = 1295 CLASS 32 = 1515 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

22 933 Wheel iameter: 57.5" Inlet Area: 5.94 ft2 Outlet Area: 5.99 ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: 28" x " RBO/R 933 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 1129 CLASS 32 = 1329 RBA MAXIMUM RPM: CLASS 22 = 1100 CLASS 32 = 1325 RBW MAXIMUM RPM: CLASS 22 = 1137 CLASS 32 = 1330 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

23 937 Wheel iameter: " Inlet Area: 7.46 ft2 Outlet Area: 7.51 ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " RBO/R 937 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 1009 CLASS 32 = 1187 RBA MAXIMUM RPM: CLASS 22= 983 CLASS 32 = 1184 RBW MAXIMUM RPM: CLASS 22 = 1015 CLASS 32 = 1188 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

24 941 Wheel iameter: 71.25" Inlet Area: 9.16 ft2 Outlet Area: 9.20 ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " RBO/R 941 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 911 CLASS 32 = 1072 RBA MAXIMUM RPM: CLASS 22 = 888 CLASS 32 = 1070 RBW MAXIMUM RPM: CLASS 22 = 917 CLASS 32 = 1024 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

25 945 Wheel iameter: 78.25" Inlet Area: ft2 Outlet Area: ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " RBO/R 945 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 837 CLASS 32 = 976 RBA MAXIMUM RPM: CLASS 22 = 809 CLASS 32 = 974 RBW MAXIMUM RPM: CLASS 22 = 835 CLASS 32 = 978 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

26 949 Wheel iameter: 85.25" Inlet Area: ft2 Outlet Area: ft 2 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " RBO/R 949 RBO Wheel used for Class 22. RBR Wheel used for Class MAXIMUM RPM: CLASS 22 = 757 CLASS 32 = 896 RBA MAXIMUM RPM: CLASS 22 = 743 CLASS 32 = 894 RBW MAXIMUM RPM: CLASS 22 = 767 CLASS 32= 900 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

27 954 Wheel iameter: 93.75" Inlet Area: ft2 Outlet Area: ft 2 RBO 954 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x " MAXIMUM RPM: CLASS 22 = 692 RBA MAXIMUM RPM: CLASS 22= 674 RBW MAXIMUM RPM: CLASS 22 = 696 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

28 960 Wheel iameter: " Inlet Area: ft2 Outlet Area: ft 2 RBO 960 Tip Speed (FPM): x RPM Inlet iameter: " O.. Outlet imension: " x 57" MAXIMUM RPM: CLASS 22 = 622 RBA MAXIMUM RPM: CLASS 22 = 607 RBW MAXIMUM RPM: CLASS 22 = 627 Performance certified is for installation type B & : Free or ducted inlet, ducted outlet. Power ratings (BHP) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Underlined figures indicate maximum static efficiency. Regular face type = Class 22 Bold face type = Class Twin City Bulletin 902

29 imensional ata RBO, RBA, & RBW, Arr. 9A & 9B, Class 22 GA GA. SIES NOTE 4 NOTE 1 HJ ISCH Q HC HN KL SE S IA. SFT X ISCH FLANGE NOTE 1 KS KWY P GB J B OUTSIE A HOUSING ISCH GA. SCROLL C O.. INLET ISCH JA NOTE 5 GC G CW TH ROTATABLE BA BASE ANGLE H N WITH OPTIONAL FLANGE INLET HF HK H HH HC HN HK HF HJ H HK HJ HH CW TA CW TAU CW UB CW BAU CW BH FOUNATION PLAN SIX BH IA. BASE HOLES K K L M FAN HSG FAN SFT M NOTES: 1. Outlet flanges are optional. Flanges are punched per drawing AC CW rotation is shown. CCW rotation is similar but opposite. 3. For 'B' (downblast) see drawing AC Motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 5. Optional flanged inlet per drawing AC FAN FR A B BA BH C X 9A 9B 9A 9B G GA GB x T 215T x T 256T x T 256T x T 286T x T 286T x T 326T x T 365T FAN H 9A 9B HC H HF HH HJ HK HN J FAN L P WEL K KL KS M N Q S SE 9A 9B 9A 9B IAMETER x x x x x x x AC15074 imensions are not to be used for construction. Certified drawings are available upon request. 29 Twin City Bulletin 902

30 imensional ata RBO, RBA, & RBW, Arr. 1 & 9A, Class 22 MOTOR ARR 9 ONLY GA GA. SIES NOTE 3 ISCH Q HC S IA. SFT KL SE X ISCH FLANGE NOTE 1 KS KWY BA P BASE ANGLE B OUTSIE A HOUSING GB ISCH GA. SCROLL J C O.. INLET ISCH JA NOTE 4 GC G CW TH NON-ROTATABLE H N WITH OPTIONAL FLANGE INLET HP HF H HH HC HF H HH NOTE 1 CW B CW TA CW TAU CW UB CW BAU CW BH NOTE 5 KA KB L M M FAN HSG FAN SFT AH B ONLY NOTES: 1. Outlet flanges punched per drawing AC15146 except 'B' is punched per foundation plan. 'B' "punched" outlet is per drawing AC CW rotation is shown. CCW rotation is similar but opposite. 3. Arrangement 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 4. Optional flanged inlet per drawing AC Use dimension 'KB' for 'B'. SIX BH IA. BASE HOLES (EIGHT HOLES ON B ) FOUNATION PLAN FAN A AH B BA BH C X FR G GA GB x T x T x T x T FAN GC H H HF HH HP J JA FAN WEL KA KB KL KS L M N P Q S SE IAMETER x x x x AC15063 imensions are not to be used for construction. Certified drawings are available upon request. 30 Twin City Bulletin 902

31 imensional ata RBO, RBA, & RBW, Arr. 9B, Class 22 GA GA. SIES NOTE 3 ISCH Q HC KL SE S IA. SFT X P ISCH FLANGE NOTE 1 KS KWY B OUTSIE A HOUSING GB ISCH GA. SCROLL J C O.. INLET ISCH JA NOTE 4 BA BASE ANGLE GC G CW TH NON-ROTATABLE H N WITH OPTIONAL FLANGE INLET HP HF H HH HC HF H HH NOTE 1 CW B CW TA CW TAU CW UB CW BAU CW BH NOTE 5 KA KB L M M FAN HSG FAN SFT AH SIX BH IA. BASE HOLES (EIGHT HOLES ON B ) FOUNATION PLAN B ONLY NOTES: 1. Outlet flanges punched per drawing AC15146 except angles on 'B' punched per foundation plan. 2. CW rotation is shown. CCW rotation is similar but opposite. 3. Motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 4. Optional flanged inlet per drawing AC Use dimension 'KB' for 'B'. FAN A AH B BA BH C X FR G GA GB x T x T x T x T FAN GC H H HF HH HP J JA FAN WEL KA KB KL KS L M N P Q S SE IAMETER x x x x AC15075A imensions are not to be used for construction. Certified drawings are available upon request. 31 Twin City Bulletin 902

32 imensional ata RBO, RBA, & RBW, Arr. 1 & 9, Class 22 MOTOR ARR 9 ONLY GA GA. SIES NOTE 3 ISCH Q C HC S IA. SFT KL SE X ISCH FLANGE NOTE 1 KS KWY BA P BASE ANGLE B OUTSIE A HOUSING GB ISCH GA. SCROLL C L J C O.. INLET ISCH JA NOTE 4 GC G CW TH NON-ROTATABLE H N WITH OPTIONAL FLANGE INLET HP HF H HH HC HF H HH A B E F G NOTE 1 CW B CW TA CW TAU CW UB CW BAU CW BH M M AH NOTE 5 KA KB L FAN HSG FAN SFT SIX BH IA. BASE HOLES (EIGHT HOLES ON B ) FOUNATION PLAN B ONLY NOTES: 1. Outlet flanges punched per drawing AC15146 except 'B' is punched per foundation plan. 'B' "punched" outlet is per drawing AC CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 4. Optional flanged inlet per drawing AC Use dimension 'KB' for 'B'. FAN A AH B BA BH A B C E F G X x x x x x x x FAN FR G GA GB GC H HC H HF HH HP T T T T T T T FAN WEL J JA KA KB KL KS L M N P Q S SE IAMETER x x x x x x x AC15064A imensions are not to be used for construction. Certified drawings are available upon request. 32 Twin City Bulletin 902

33 imensional ata RBA, RBO, RBP, & RBW, Arr. 1 & 9, Class 32 MOTOR ARR 9 ONLY GA GA. SIES NOTE 3 NOTE 1 HJ ISCH HC HN Q KL SE S IA. SFT X P ISCH FLANGE NOTE 1 KS KWY BA BASE ANGLE B OUTSIE A HOUSING GB ISCH GA. SCROLL J C O.. INLET ISCH JA NOTE 4 GC G CW TH NON-ROTATABLE H N WITH OPTIONAL FLANGE INLET HF HK H HH HC HN HK HF HJ H HK HJ HH CW TA CW TAU CW UB CW BAU CW BH KA KB L M FAN HSG FAN SFT M NOTES: 1. Outlet flanges are optional. Flanges are punched per drawing AC CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 4. Optional flanged inlet per drawing AC For 'B' (downblast) see drawing AC SIX BH IA. BASE HOLES (EIGHT HOLES ON B ) FOUNATION PLAN FAN FR A B BA BH C X ARR. 1 ARR. 9 ARR. 9 G GA GB GC x T x T x T x T x T FAN H ARR. 1 ARR. 9 HC H HF HH HJ HK HN J JA FAN L P WEL K KL KS M N Q S SE ARR. 1 ARR. 9 ARR. 1 ARR. 9 IAMETER x x x x x AC15065 imensions are not to be used for construction. Certified drawings are available upon request. 33 Twin City Bulletin 902

34 imensional ata RBA, RBO, RBP, & RBW, Arr. 1 & 9, Class 32 MOTOR ARR 9 ONLY GA GA. SIES NOTE 3 ISCH Q HC S IA. SFT KL SE X ISCH FLANGE NOTE 1 KS KWY BA P BASE ANGLE B OUTSIE HOUSING A GB ISCH GA. SCROLL J C O.. INLET ISCH JA NOTE 4 GC G CW TH NON-ROTATABLE H N WITH OPTIONAL FLANGE INLET HP HF H HH HC HF H HH NOTE 1 CW B CW TA CW TAU CW UB CW BAU CW BH NOTE 5 M M AH KA KB L FAN HSG FAN SFT SIX BH IA. BASE HOLES (EIGHT HOLES ON B ) FOUNATION PLAN B ONLY NOTES: 1. Outlet flanges punched per drawing AC15147 except 'B' is punched per foundation plan. 'B' "punched" outlet is per drawing AC CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 4. Optional flanged inlet per drawing AC Use dimension 'KB' for 'B'. FAN FR A AH B BA BH C X ARR. 1 ARR. 9 ARR. 9 G GA GB x T x T x T x T FAN H GC ARR. 1 ARR. 9 HC H HF HH HP J JA KA FAN L P WEL KB KL KS M N Q S SE ARR. 1 ARR. 9 ARR. 1 ARR. 9 IAMETER x x x x AC15066 imensions are not to be used for construction. Certified drawings are available upon request. 34 Twin City Bulletin 902

35 imensional ata RBA, RBR, & RBW, Arr. 1 & 9, Class 32 GA GA. SIES ISCH HC X ISCH FLANGE NOTE 1 P J B OUTSIE A HOUSING ISCH JA NOTE 4 MOTOR ARR 9 ONLY NOTE 3 GC G Q C S IA. SFT CW TH NON-ROTATABLE KL SE KS KWY BA BASE ANGLE H GB ISCH GA. SCROLL N C O.. INLET WITH OPTIONAL FLANGE INLET HP HF H HH HC HF H HH A B E F G NOTE 1 CW B CW TA CW TAU CW UB CW BAU CW BH NOTE 5 KA KB L M M FAN HSG FAN SFT AH SIX BH IA. BASE HOLES (EIGHT HOLES ON B ) FOUNATION PLAN B ONLY NOTES: 1. Outlet flanges punched per drawing AC15147 except 'B' is punched per foundation plan. 'B' "punched" outlet is per drawing AC CW rotation is shown. CCW rotation is similar but opposite. 3. Arrg. 9 motor location is 'left' for 'CW' rotation and 'right' for 'CCW' rotation. imension 'FR' is Max. Motor Frame. 4. Optional flanged inlet per drawing AC Use dimension 'KB' for 'B'. FAN A AH B BA BH C A B C E F G X x x x x x FAN FR ARR. 9 G GA GB H HC H HF HH HP T T T T T FAN WEL J JA KA KB KS L M N P Q S SE IAMETER x x x x x AC15067A imensions are not to be used for construction. Certified drawings are available upon request. 35 Twin City Bulletin 902

36 LC LC imensional ata Arr. 9F, Class 32 P J JA HP HF Q HC KL SE KS KWY B OUTSIE HOUSING A ISCH. C O.. INLET ISCH. CW B H HH A H B HC CW TA C S IA. SFT TH 1 /2 G CW TH V N WITH OPTIONAL G H FLANGE INLET NOTES: 1. Clockwise (CW) rotation shown. Counterclockwise (CCW) rotation is similar but opposite. 2. Sizes 911 through 919 are rotatable. Sizes 921 through 949 are non-rotatable. 3. Optional flanged inlet is shown. See page 38 for dimensional data. 4. Punched outlet flange is optional on sizes 911 through 919 and standard on sizes 921 through 949. See page 38 for dimensional data. 5. Standard Arr. 9F motor location is on the left for CW rotation units, and on the right for CCW rotation units (unless otherwise specified.) 6. Use dimension KB in place of KA for B. S S S (ALL ISCRGES EXCEPT B) (B ONLY) (ALL ISCRGES) "BH" IA. BASE HOLES NOTE 6 MOTOR FAN SFT LC MOTOR LC FAN SFT HF K FAN HSG. KA FAN HSG. K KB LC B FAN HSG. KB ONLY LC KB L T "BH" IA. L BASE HOLES T L T "BH" IA. S M M BASE HOLES S M M AH S M M AH A AH B BH C A B C E F G G H B Others LC MOTOR CW BAU CW TAU HH F LC FAN SFT E CW UB CW BH G HC H HF HH HP J JA K KA KB KL KS x x x x x x x x x x x x x x.63 L P T V MAX. MOTOR B Others M N B Others Q S S SE B Others B Others FRAME T T T T T T T T T T T T T T AC15072F AC15136A AC15137A AC15138B IMENSIONS ARE NOT TO BE USE FOR CONSTRUCTION. CERTIFIE RAWINGS AVAILABLE ON REQUEST. 36 Twin City Bulletin 902

37 imensional ata Arrangement 10 Size 905 HC CL SFT ISCH. A CL OUTS. HSG. Q 1.75 TYP. KS KWY SE KL P B OUTS. HSG. J C O.. INLET KA FOUNATION PLAN TOP VIEW CL HSG. HC CL SFT H HH CL SFT G GC S IA. SFT H CL HSG. KB CL SFT M M 3.13 (4) BH IA. BASE HOLES CW UB CW TAU HN CL SFT CL SFT CW BH CW B Sizes HP HF GA GA. SIES NOTE 1 HJ P J JA NOTE 3 H MOTOR "FR" MAX. FRAME GC G Q HN HC OPTIONAL WEATR COVER 1.00 TYP. CW TH ROTATABLE KL SE X ISCH. FLANGE NOTE 1 KS KWY S IA. SFT B OUTSIE HOUSING A H GB GA. SCROLL N C O.. INLET BA BASE ANGLE ISCH. LC WITH OPTIONAL FLANGE INLET KA KB L M FAN HSG. LC FAN SFT LC M FOUNATION PLAN (6) "BH" IA. BASE HOLES CW B H HH CW TAU HH HC HF CW UB CW TA NOTES: CW BAU CW BH 1. Clockwise (CW) rotation shown, counterclockwise (CCW) rotation is similar but opposite. 2. All sizes are rotatable. 3. Optional flanged inlet shown on sizes 907 through 919. An optional flanged inlet is available on all Arrangement 10 sizes, including size 905. See page 38 for dimensional data. 4. Punched outlet flange is optional on all sizes. See page 38 for dimensional data. 5. Weather cover is optional. 6. All Arrangement 10 fans are available as Class 22 only. A B BH C G GC H HC H HF HH HN J JA KA KB KL KS L M N P Q S SE MAX. MTR x T x T x T x T x T x T x T x T AC15142A IMENSIONS ARE NOT TO BE USE FOR CONSTRUCTION. CERTIFIE RAWINGS AVAILABLE ON REQUEST. 37 Twin City Bulletin 902

38 imensional ata Inlet & Outlet Flanges Inlet Flange O.. C A B C E A B C E () "E" IA. HOLES EQUALLY SPACE B.C. B A I AC15143B Outlet Flange C A C A J E B "K" "L" B E (N) "M" IA. HOLES J (N) "M" IA. HOLES Class 22 C C A B C E F G H J K L M N ANGLE x x x x x x x x x x x x x x x x x x x 3.00 Class 32 A B C E F G H J K L M N ANGLE x x x x x x x x x x x x x x 3.00 IMENSIONS ARE NOT TO BE USE FOR CONSTRUCTION. CERTIFIE RAWINGS AVAILABLE UPON REQUEST. C F "G" "H" S S F C AC15146C AC Twin City Bulletin 902

39 Typical Specifications Fans shall be Type RBO/RBR/RBW/RBA/RBP Industrial Fans, as manufactured by Twin City Fan & Blower, Minneapolis, Minnesota. Performance Fans shall be tested in accordance with AMCA 210 test code for air moving devices and shall be guaranteed by the manufacturer to deliver rated published performance levels. RBO, RBR, RBW and RBA fans shall be licensed to bear the AMCA certified ratings seal for air. Housing Housings shall be continuously welded heavy gauge steel, suitably braced to prevent pulsation. Housings with lock seams or partially welded construction are not acceptable. Class 22 housings shall be constructed of a minimum 12 gauge through 0.31" steel. Class 32 housings shall be constructed of at least 7 gauge through 0.31" steel. Units having wheel diameters of 33" (size 919) and smaller shall be built with adjustable discharge housings which can be field rotated to any of the eight standard positions. Fans with wheel diameters larger than 33" shall be built with a fixed discharge housing and have a flanged type discharge to provide unit rigidity. Wheel All class 22 fan wheels shall be constructed of a minimum 10 gauge through 0.75" thick steel. Class 32 fan wheels shall be constructed of a minimum 7 gauge through 0.75" steel. The spider hubs for RBO wheels shall be fabricated steel or cast steel material. All industrial fan wheels shall be continuously welded. Shaft Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed. Bearings Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type and selected for a minimum average bearing life (AFBMA L-50) in excess of 200,000 hours at the maximum fan RPM. V-BELT rive Fan and motor sheaves shall be cast iron fixed pitched drives for service over 10 HP. Small drives may use variable pitch cast iron motor sheaves. The minimum belt service factor is 120% for drives through 25 HP and 150% over 25 HP. Finish and Coating The entire fan assembly, excluding the shaft, shall be thoroughly degreased and deburred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum components shall be unpainted. Accessories When specified, accessories such as inlet vanes, outlet dampers, companion inlet and outlet flanges, inlet bells, inlet boxes, shaft guards, and wheel and scroll liners shall be provided by Twin City Fan & Blower to maintain one source responsibility. Factory Run Test All fans prior to shipment shall be completely assembled and test run as a unit at the specified operating speed or maximum RPM allowed for the particular construction type. Each wheel shall be statically and dynamically balanced in accordance with ANSI/AMCA Balance Quality and Vibration Levels for Fans to Fan Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. Guarantee The manufacturer shall guarantee the workmanship and materials for its fans for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first. 39 Twin City Bulletin 902

40 Industrial & Commercial Fans Centrifugal Fans Utility Sets Plenum & Plug Fans Inline Centrifugal Fans Mixed Flow Fans Tubeaxial & Vaneaxial Fans Propeller Wall Fans Propeller Roof Ventilators Centrifugal Roof & Wall Exhausters Ceiling Ventilators Gravity Ventilators uct Blowers Radial Bladed Fans Radial Tip Fans High Efficiency Industrial Fans Pressure Blowers Laboratory Exhaust Fans Filtered Supply Fans Mancoolers Fiberglass Fans Custom Fans A Twin City Fan Company Twin city fan & blower Trenton Lane N Minneapolis, MN Phone: Fax: MWG12/10

The Industrial Choice. INDUSTRIAL FANS MHO / MHR / MHA / MHW / MHP CLASS 22 & 32

The Industrial Choice. INDUSTRIAL FANS MHO / MHR / MHA / MHW / MHP CLASS 22 & 32 The Industrial Choice. INUSTRIAL S HO / HR / / HW / HP CLASS 22 & 32 CATALOG 710 February 2013 Industrial Fans odels - Class 22 & 32 HO I HR I I HW I HP The H Series Industrial Fans manufactured by Aerovent

More information

TURNING AIR INTO SOLUTIONS. INDUSTRIAL FANS RBA RBO RBR RBW RBP

TURNING AIR INTO SOLUTIONS. INDUSTRIAL FANS RBA RBO RBR RBW RBP TURNING AIR INTO SOLUTIONS. INUSTRIAL S RBA RBO RBR RBW RBP CATALOG 902 November 2017 INUSTRIAL S Overview RBA I RBO I RBR I RBW I RBP The Radial Bladed Industrial Fans are designed for applications with

More information

Turning Air Into Solutions. PLUG FANS TYPE BCPL

Turning Air Into Solutions. PLUG FANS TYPE BCPL Turning Air Into Solutions. PLUG FANS TYPE BCPL CATALOG 350 December 2009 BCPL Plug Fans BCPL plug fans from Twin City Fan & Blower are compact and versatile. Their versatility allows them to be used for

More information

Defining Innovation. backward curved FANs

Defining Innovation. backward curved FANs Defining Innovation. high efficiency industrial backward curved FANs TYPE HIB BULLETIN 00-B May 20 HIB High-Efficiency Industrial Backward-Curved Fans Model HIB fans from Twin City Fan & Blower employ

More information

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications...

Industrial Material Handler Page Introduction... 2 Information Specifications MH Specifications... 6 MHR Specifications... Industrial Material Handler Page Introduction.......................................... 2 Information.......................................... 3-5 Specifications MH Specifications.....................................

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 370 January 2007 AIRFOIL FANS TYPE BAE SWSI and DWDI BAE SWSI and DWDI Airfoil Fans Featuring the E-Series Wheel This catalog features the new BAE airfoil wheel design.

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS

Bulletin BCF 103 DESIGN 10A BACKWARD INCLINED WHEELS Bulletin BCF 10 DESIGN 10A BACKWARD INCLINED WHEELS Proven Reliability in Industrial Environments and Corrosive Atmospheres Design 10A s with Backward Inclined Wheels Chicago s Design 10A is a rugged multi-purpose

More information

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009

Defining Innovation. radial tip FaNS type Hrt BULLETIN 980 October 2009 Defining Innovation. radial tip FANS TYPE HRT BULLETIN 980 October 2009 HRT Radial Tip Fans Twin City Fan & Blower s Type HRT Industrial Duty Radial Tip Fan line is engineered for higher specific speeds.

More information

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice. UTILITY BLOWERS Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB The Industrial Choice. CATALOG 760 April 2017 Utility Blowers Overview Utility Blowers Aerovent s line of utility blowers is one of the most

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 300-F January 2009 BACWARD INCLINED FANS TYPE BC SWSI & DWDI BC SWSI & DWDI Backward Inclined Fans This catalog features type BC non-overloading centrifugal fans in SWSI

More information

Air Moving Solutions. AIRFOIL fans

Air Moving Solutions. AIRFOIL fans Air Moving Solutions. AIRFOIL fans BAE SWSI BAE DWDI CATALOG 370 December 2012 AirfoilFans Models BAE SWSI & BAE DWDI Featuring the E-Series Wheel This catalog features the new BAE airfoil wheel design.

More information

Centrifugal Utility Fans - SFD/SFB

Centrifugal Utility Fans - SFD/SFB C H F D B G E A Centrifugal Utility Fans - SFD/SFB SFB STANDARD CONSTRUCTION FEATURES HOUSING: Heavy gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan RADIAL TIP FANS MODEL RTF   CATALOG 950 AUGUST 2012 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS RADIAL TIP FANS MODEL RTF CATALOG 950 AUGUST 2012 RADIAL TIP FANS Model RTF Model RTF radial tip fans are of a heavy duty, rugged design,

More information

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven Model CBD Belt Driven Model CDD Direct Drive CENTAXIAL TUBULAR CENTRIFUGAL FANS BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) CATALOG 337 February 2004 Centaxial

More information

Twin City Fan & Blower

Twin City Fan & Blower BULLETIN 600 Twin City Fan & Blower September 2009 VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE

More information

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Standard Design Features Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans Shaft AISI 1045, turned ground and polished for accuracy. Designed to provide

More information

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV CATALOG 600 March 2012 VentilatingSets Models BCV BCVU5 BCVU2 BCVSH BAV FCV Twin City Fan s line of utility ventilating sets is one

More information

BACKWARD CURVED HIGH PRESSURE FANS

BACKWARD CURVED HIGH PRESSURE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BACKWARD CURVED HIH PRESSURE FANS MODEL BCS CATALOUE M400 DECEMBER 203 CENTRIFUAL FANS Model BCS Backward Curved - High Pressure The

More information

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven BULLETIN 456 July 1997 VANEAXIAL FANS Type W Direct Drive/Belt Driven Model VW Direct Drive Model VWBD Belt Driven Aerovent certifies that the Type W Vaneaxial Fans shown herein are licensed to bear the

More information

TURBO PRESSURE BLOWERS

TURBO PRESSURE BLOWERS Twin City Fan INUSTRIAL PROCESS AN COMMERCIAL VENTILATION SYSTEMS TURBO PRESSURE BLOWERS TBNA TBNS CATALOG 12 AUGUST 14 TURBO PRESSURE BLOWERS Overview TBNA I TBNS The TBN series of fans are low volume,

More information

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV CATALOG 600 March 2017 UTILITY SETS Model DCV Overview Utility Sets Twin City Fan s line of utility ventilating sets is one of the

More information

Mixed Flow Inline Fan, Model MFSI

Mixed Flow Inline Fan, Model MFSI Mixed Flow Inline Fan, Model MFSI TABLE OF CONTENTS 3 Introduction, Certifications & Listings 4 Features & Benefits 5 Options & Accessories 6 Dimensional Data 10 Performance Data 27 Sound Data 44 Engineering

More information

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011

Defining Innovation. high efficiency industrial AiRfoiL fan TyPe haf BULLETIN 1150 May 2011 Defining Innovation. high efficiency INDUSTRIAL airfoil FAN TYPE HAF BULLETIN 1150 May 2011 HAF High Efficiency Industrial Airfoil Fans Model HAF fans from Twin City Fan & Blower employ a high efficiency

More information

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN

TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN TURNING AIR INTO SOLUTIONS. COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 June 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower VENTILATING SETS TYPE BCV (Backward Inclined) TYPE BCVU5 (UL 705 Listed) TYPE BCVU2 (UL 762 Listed) TYPE BCVSH (UL Smoke & Heat) TYPE BAV (Airfoil) TYPE FCV (Forward Curved) Ventilating

More information

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQBI BLOWERS BACKWARD INCLINED CLASS II CLASS IIP CLASS III 7697 Snider Road, Mason, OH 4040-913 Telephone: 13-73-0600 Visit us at www.cincinnatifan.com for more

More information

VANEAXIAL & TUBEAXIAL FANS

VANEAXIAL & TUBEAXIAL FANS BULLETIN 482 July 2008 VANEAXIAL & TUBEAXIAL FANS Type "S" Belt Driven Featuring Welded Steel Propellers Models VSBD & TSBD Model TSBD Belt Driven Tubeaxial Type "S" Vaneaxial & Tubeaxial Fans For applications

More information

FRP Fans: CLUB Series Performance and Technical Information

FRP Fans: CLUB Series Performance and Technical Information FRP Fans: CLUB Series 1500-7300 Performance and Technical Information Verantis Environmental Solutions Group provides solutions for most common and complex situations including repair, rebuilding, field

More information

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist

SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III. OEM and Industrial Air Handling Specialist OEM and Industrial Air Handling Specialist SQAF AIRFOIL BLOWERS CLASS IP CLASS II CLASS IIP CLASS III 69 Snider Road, Mason, OH 4040-913 Telephone: 13-3-0600 Visit us at www.cincinnatifan.com for more

More information

The Industrial Choice. Model AMX MIXED FLOW FANS. Model AMX (Standard) Model AMXR (Restaurant) Model AMXSH (Smoke & Heat)

The Industrial Choice. Model AMX MIXED FLOW FANS. Model AMX (Standard) Model AMXR (Restaurant) Model AMXSH (Smoke & Heat) The Industrial Choice. Model AMX MIXE FLOW FANS Model AMX (Standard) Model AMXR (Restaurant) Model AMXSH (Smoke & Heat) BULLETIN 330 July 2008 AMX Mixed Flow Fans Application Mixed flow fans are becoming

More information

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS

Turning Air Into Solutions. BACKWARD CURVED HIGH PRESSURE FANS MODEL BCS Turning Air Into Solutions. BACKWARD CURVED HIH PRESSURE FANS MODEL BCS CATALOUE M400 December 203 CentrifugalFans Model BCS Backward Curved - High Pressure The BCS fan from Twin City Fan & Blower is a

More information

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS

The Industrial Choice. TURBO PRESSURE BLOWERS. Models HPBA / HPBS The Industrial Choice. TURBO PRESSURE BLOWERS Models HPBA / HPBS CATALOG 914 February Turbo Pressure Blowers Models HPBA HPBS The HPB series of fans are low volume, high-pressure blowers designed for stable

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW CATALOG 1260 APRIL 2015

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan PRESSURE BLOWERS MODEL PBW   CATALOG 1260 APRIL 2015 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS PRESSURE BLOWERS MODEL PBW CATALOG 120 APRIL WWW.TCF.COM PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high

More information

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS New Energy Saving Wheel Mounted Motors to 125 HP Pre-Engineered Sizes to 60" Capacities to 156,000 CFM CHICAGO BLOWER CORPORATION GLENDALE

More information

COMMERCIAL DUTY PLENUM FANS

COMMERCIAL DUTY PLENUM FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS COMMERCIAL DUTY PLENUM FANS EPLFN EPLQN CATALOG 455 JUNE 2014 PLENUM FANS Overview EPLFN I EPLQN Plenum fans are unhoused fans designed

More information

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A

Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Bulletin ACF 103 AIRFOIL CENTRIFUGAL FANS DESIGN 10A Quieter, More Efficient Airfoil Fans for Commercial and Light Industrial Applications Design 10A Fans with Airfoil Wheels Fourteen Sizes to 80" Volumes

More information

Good Enough Never Is. Plug Fan SERIES 12

Good Enough Never Is. Plug Fan SERIES 12 Plug Fan SERIES 12 Good Enough Never Is The Hartzell Difference Combine Hartzell QUALITY with your PRODUCT for a BETTER CHOICE for your customers! GOOD ENOUGH NEVER IS. Hartzell Air Movement is the industrial

More information

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type T Belt Driven Model TTABD / VTBD The Industrial Choice. Vane Section For Model VTBD Model TTABD TUBEAXIAL & VANEAXIAL S Type "T" Belt Driven Model TTABD / VTBD BULLETIN 424-A November 1998 Model TTABD/VTBD Tubeaxial/Vaneaxial Fans Aerovent

More information

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating. Issued 2005/06/01 Section 15831 Commercial Fans Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal..2 Section 15053 Motors, Drives and Guards..3 Section 15072

More information

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07 model vp - belt drive utility set Application VENT-PAK fan wheels are the versatile, quiet, energy efficiency backward inclined

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover.

General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. General TAHVIEH HAMOON Airfoil Centrifugal Fans Utilize the latest design techniques to product a quiet highly efficient air mover. Aerodynamically designed blades and air passages allow more air to be

More information

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group

VERANTIS. FRP Fans: CMHB Series Performance and Technical Information. Environmental Solutions Group VERANTIS Environmental Solutions Group FRP Fans: CMHB Series 6-8-10 Performance and Technical Information Bulletin 11-6 Rev May 2013 VERANTIS Environmental Solutions Group Verantis Environmental Solutions

More information

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN

TURNING AIR INTO SOLUTIONS. COMPACT PLENUM FANS ECLFN ECLQN TURNING AIR INTO SOLUTIONS. COMPACT PLENUM S ECLFN ECLQN CATALOG 456 July 2017 PLENUM S Overview ECLFN I ECLQN Plenum fans are unhoused fans designed to operate inside of field-fabricated or factory-built

More information

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone:

OEM and Industrial Air Handling Specialist Snider Road, Mason, OH Telephone: HDBI BLOWERS OEM and Industrial Air Handling Specialist BACKWARD INCLINED CLASS II CLASS III CLASS IV 797 Snider Road, Mason, OH 45040-915 Telephone: 51-57-000 Visit us at www.cincinnatifan.com for more

More information

SECTION CENTRIFUGAL HVAC FANS

SECTION CENTRIFUGAL HVAC FANS SECTION 233416 - CENTRIFUGAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI

Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Bulletin 8510-4 May 2000 Series 8500 Centrifugal Swingout Fans Design 8510 Centrifugal Airfoil Design 8520 Centrifugal BI Description Index Series 8500 Centrifugal Swingout Fans The Series 8500 Centrifugal

More information

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS

TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS TURNING AIR INTO SOLUTIONS. TURBO PRESSURE BLOWERS TBNA TBNS CATALOGUE M1250 April 2015 TURBO PRESSURE BLOWERS Overview TBNA I TBNS The TBN series of fans are low volume, high-pressure blowers designed

More information

Air Moving Solutions. AEROFOIL fans

Air Moving Solutions. AEROFOIL fans Air Moving Solutions. AEROOIL fans BAE SWSI BAE DWDI Catalogue M0 August 0 Airfoilans Models BAE SWSI & BAE DWDI eaturing the E-Series Impeller This catalogue features the new BAE aerofoil impeller design.

More information

Air Moving Solutions. AEROFOIL fans

Air Moving Solutions. AEROFOIL fans Air Moving Solutions. AEROOIL fans BAE SWSI BAE DWDI Catalogue M0 August 0 Airfoilans Models BAE SWSI & BAE DWDI eaturing the E-Series Impeller This catalogue features the new BAE aerofoil impeller design.

More information

turbo pressure blowers

turbo pressure blowers efining Innovation. turbo pressure blowers TYPE TBNA TBNS BULLETIN May TBN Turbo Pressure Blowers Introduction The TBN series of fans are low volume, high-pressure blowers designed for stable operation

More information

Tubular Centrifugal Fans

Tubular Centrifugal Fans Tubular Centrifugal Fans Model TCB Inline - Horizontal or Vertical Roof Upblast and Roof Supply March 2007 Tubular Centrifugal Fans The TCB series of inline centrifugal fans is designed for ducted inline,

More information

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW

TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS. Model PBW TURNING AIR INTO SOLUTIONS. PRESSURE BLOWERS Model PBW CATALOG 120 April PRESSURE BLOWERS Overview Model PBW The PBW is designed for low flow and high static pressures, yet stable operation throughout

More information

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG

VANEAXIAL FANS. DUCT FANS Capacities to 60,000 CFM Static pressures to 2 WG. TUBEAXIAL FANS Capacities to 86,000 CFM Static pressures to 3 WG BULLETIN 671 AUGUST, 2016 VANEAXIAL FANS DUCT FANS Capacities to 60,000 Static pressures to 2 WG TUBEAXIAL FANS Capacities to 86,000 Static pressures to 3 WG Capacities to 0,000 Static pressures to 5 WG

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 MARCH, 2014 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

PEERLESS ELECTRIC INDUSTRIAL FANS

PEERLESS ELECTRIC INDUSTRIAL FANS PEERLESS ELECTRIC INDUSTRIAL FANS HIGH QUALITY HIGH EFFICIENCY VERSATILITY TYPICAL INDUSTRIES PEERLESS ELECTRIC HAS SERVED FOR MORE THAN 95 YEARS HVAC Paint Chemical Clothing Leather Steel Aviation Plastic

More information

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct Tubular Centrifugal Inline Fans Page Introduction........................................... 2 Construction Features.................................. 3 Specification and Dimension Data TCN-D (Inline Fan-

More information

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio

Vaneaxial Fans. Series 25 Series 53 Series 53C Series 54 Series 55 HARTZELL. Hartzell Fan, Inc., Piqua, Ohio Vaneaxial Fans Series 25 Series 53 Series 53C Series 54 Series 55 BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 45356 February 2008 Index Model Code Explanation...Page

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

forward curved inline duct blowers

forward curved inline duct blowers Defining Innovation. forward curved inline duct blowers TYPE DBS (Single) DBT (Twin) BULLETIN 4220 January 2011 Duct Blowers General Information Twin City Fan s belt driven DBS (single) and DBT (twin)

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX100-A October 2008 AXIFAN VANEAXIAL FANS TYPE TCVA TCVA Vaneaxial Fans The heart of the TCVA AXIFAN fan lies in its wheel. Cast of high strength aluminum alloy, the one-piece

More information

AXIFAN VANEAXIAL FANS

AXIFAN VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXIFAN VANEAXIAL FANS MODEL TCVA CATALOG AX100 JUNE 2013 VANEAXIAL FANS Model TCVA The heart of the TCVA AXIFAN fan lies in its wheel.

More information

& 12" 96" / TABD CATALOG

& 12 96 / TABD CATALOG The Industrial Choice. Model TA Direct Drive Model TABD Belt Driven TUBEAXIAL S Macheta Airfoil Design Direct Drive & Belt Driven Sizes 2" through 96" Models TA / TABD CATALOG 5 August 204 Tubeaxial Fans

More information

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements

SURGE LIMITING PB FANS. Designed for high pressure, low flow applications with stringent job process requirements SURGE LIMITING BULLETIN 485 APRIL, 2017 PB FANS Designed for high pressure, low flow applications with stringent job process requirements Capacities to 30,000 CFM Static pressures to 180 WG Temperatures

More information

Air Moving Solutions. axifan adjustable blade vaneaxial fans

Air Moving Solutions. axifan adjustable blade vaneaxial fans Air Moving Solutions. axifan adjustable blade vaneaxial fans MODEL TCVX CATALOG AX300 December 2012 VaneaxialFans Model TCVX The heart of the TCVX AXIFAN lies in its wheel. The manually adjustable blades

More information

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD The Industrial Choice. Model SCDD Direct Drive Model SCBD Belt Driven SQUARE INLINE FANS Direct Drive & Belt Driven Model SCDD / SCBD BULLETIN 40 January 007 Square Inline Centrifugal Fans General Information

More information

Fixed Pitch Vane Axial Fan

Fixed Pitch Vane Axial Fan Fixed Pitch Vane Axial Fan Page Introduction...........................................2 Construction Features...................................3 Mounting Options.......................................3

More information

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200

Defining Innovation. turbo pressure blowers. Twin City Catalog 1200 Defining Innovation. turbo pressure blowers MODEL TBA TBR 1 Twin City Catalog CATALOG -A May 11 Model TBA/TBR Turbo Pressure Blowers Model TBA and TBR fans from Twin City Fan & Blower are constant pressure,

More information

LOW PRESSURE MIXED FLOW FANS

LOW PRESSURE MIXED FLOW FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS LOW PRESSURE MIXED FLOW FANS QCLB QCLBR QCLBSH CATALOG 1070 JANUARY 2017 MIXED FLOW FANS Models QCLB QCLBR QCLBSH QCLB (Horizontal) Benefits

More information

Turbo Pressure Blowers

Turbo Pressure Blowers www.americanfan.com Bulletin VP4 Turbo Pressure Blowers Howden Industrial Fan Group American Fan / Joy Fan / Garden City Fan Features Heavy gauge continuously welded housings, reversible and rotatable

More information

Cyclone Custom Centrifugal Fans

Cyclone Custom Centrifugal Fans Cyclone Custom Centrifugal Fans A L P H A I R Custom Engineered Centrifugal Fans ALPHAIR s line of custom engineered centrifugal fans is ideally suited for applications that involve moving air at higher

More information

BACKWARD INCLINED fans

BACKWARD INCLINED fans Air Moving Solutions. BACKWARD INCLINED fans BC SWSI BC DWDI Catalogue M00 August 0 BackwardInclinedans Models BC SWSI & BC DWDI This catalogue features Model BC non-overloading centrifugal fans in SWSI

More information

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD

The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS. Direct Drive & Belt Driven Model VJ / VJBD The Industrial Choice. Model VJ Direct Drive MANUALLY ADJUSTABLE-AT-REST VANEAXIAL FANS Direct Drive & Belt Driven Model VJ / VJBD CATALOG 476 June 2015 Vaneaxial Fans Model VJ / VJBD Type "J" The heart

More information

BACKWARD INCLINED FANS

BACKWARD INCLINED FANS Twin City an INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS BACKWARD INCLINED ANS BC-SW BC-DW CATALOGUE M00 AUGUST 0 BACKWARD INCLINED ANS Models BC SWSI & BC DWDI BC DWDI Arrangement Refer to Catalogue

More information

Inline and Roof Mounted Fans

Inline and Roof Mounted Fans CV Inline and Roof Mounted Fans Page Introduction........................................... 2 Construction Features................................. 3-4 Specifications and Dimension Data CVD (Direct Drive

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust)

Defining Innovation. mixed flow fans. TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust) Defining Innovation. mixed flow fans TYPE QSL (Standard) QSLR (Restaurant) QSLSH (Smoke and Heat) QFE (Fume Hood Exhaust) BULLETIN 1060 February 2011 QSL Mixed Flow Fans Benefits of Mixed Flow Fans Twin

More information

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F.

PRESSURE BLOWERS. Capacities to 5,200 CFM Two wheel choices. Static pressures to 58 WG Temperatures to 600 F. BULLETIN 451 SEPTEMBER, 2011 PRESSURE BLOWERS Capacities to 5,200 Two wheel choices Static pressures to 58 WG Temperatures to 600 F. THE NEW YORK BLOWER COMPANY 7660 Quincy Street Willowbrook, IL 60527-55

More information

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS Macheta Airfoil Design Model BD40C BULLETIN 616 July 1997 Upblast Axial Model BD40C Roof Ventilators The Model BD40C is the most versatile

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN 4810 August 2005 PROPELLER WALL S DIRECT AND BELT DRIVE TYPE WPMD/WPMB WPMD/WPMB Propeller Wall Fans Twin City Fan & Blower WPMD and WPMB Medium Duty Propeller Wall Fans

More information

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD The Industrial Choice. Model VB Direct Drive Model VBBD Belt Driven VANEAXIAL FANS Direct Drive & Belt Driven Model VB / VBBD BULLETIN 466 November 2000 Contents Construction Features Belt Driven... 3

More information

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC

TURNING AIR INTO SOLUTIONS. AIR KITS. Model FC TURNING AIR INTO SOLUTIONS. AIR KITS Model FC CATALOG 150 June 2017 AIR KITS Overview FC Wheel Construction Air kit wheels are designed for speeds up to 7,000 ft/min. at 70 F. The blades are die-formed

More information

Inline Fans [ 14 ] * UL is optional and must be specified.

Inline Fans [ 14 ] * UL is optional and must be specified. XTIF, XIB and XID models are listed for electrical (UL/C-UL US 705) File no. E40001. Model XTIF is available with the UL 762 Listing (Power Ventilators for Restaurant Exhaust Appliances). Accurex, LLC

More information

BACKWARD INCLINED BI AND BIA INDUSTRIAL SWSI CENTRIFUGAL FANS

BACKWARD INCLINED BI AND BIA INDUSTRIAL SWSI CENTRIFUGAL FANS BLLEIN 71-D November 2004 BACKWARD INCLINED BI AND BIA INDSRIAL SWSI CENRIFGAL FANS BI Flat Blade Design BIA Airfoil Blade Design Class I, II, III, IV BI & BIA Industrial Centrifugal Fans Aerovent s BI

More information

Centrifugal Plenum Fan

Centrifugal Plenum Fan PLC Loren Cook Company is proud to be the world leader of industrial and commercial fans and blowers. With a commitment of over 60 years, Loren Cook Company believes in superior quality and phenomenal

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MIXED FLOW FANS QSL QSLR QSLSH CATALOG 1060 MARCH 2017

INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS. Twin City Fan MIXED FLOW FANS QSL QSLR QSLSH   CATALOG 1060 MARCH 2017 Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS MIXED FLOW FANS QSL QSLR QSLSH CATALOG 1060 MARCH 2017 WWW.TCF.COM MIXED FLOW FANS Overview QSL QSLR QSLSH Benefits of Mixed Flow Fans

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

to meet the updated test procedures outlined in the 1974 AMCA test code.

to meet the updated test procedures outlined in the 1974 AMCA test code. Sheldons Engineering is a long-standing member of AMCA The Air Movement and Control Association which acts as an independent association for fan manufacturers. As you may be aware, Sheldons Engineering

More information

BACKWARD INCLINED FANS

BACKWARD INCLINED FANS Twin City Fan INDUSTRIAL ROCESS AND COERCIAL VENTILATION SYSTES BACWARD INCLINED FANS BC-SW BC-DW CATALO 300 AUUST 2014 WWW.TCF.CO BACWARD INCLINED FANS odels BC-SW BC-DW BC-SW Arrangement 8 The BC is

More information

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories IRECT RIVE TUBEAXIAL FANS Model LIA Model LIA IRECT RIVE TUBEAXIAL FANS SECTION 12 Application Carnes Company tubeaxial fans offer one of the widest ranges of sizes, horsepower and performance in the industry.

More information

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tube Axial Fan Page Specifications & Dimension Data Performance Data Tube Axial Fan Page Introduction........................................... 2 Construction Features................................... 3 Information........................................... 4 Specifications

More information

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS

DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS Catalog 6131 DF / DFB / DFC DOUBLE WIDTH DOUBLE INLET FORWARD CURVED FANS FOR ORIGINAL EQUIPMENT MANUFACTURES SERIES 1600 1/98 APPLICATIONS AND AVAILABLE TYPES DF - DFB - DFC DOUBLE INLET FANS DOUBLE INLET

More information

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S MODEL TCBS CATALOG AX220 MAY 2013 TUBEAXIAL S Model TCBS The Twin City Fan & Blower model TCBS

More information

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL

Fiberglass Axial Flow Fans. Series 28 Series 28B. Series 34 Series 35 Series 35V. Series 29 Series 29B HARTZELL Fiberglass Axial Flow Fans Series 28 Series 28B Series 29 Series 29B Series 34 Series Series V BUILT WITH HONOR HARTZELL FAN, INC PIQUA, OHIO USA HARTZELL Hartzell Fan, Inc., Piqua, Ohio 46 Bulletin A-39-N

More information

INLET BOXES AND INLET-BOX DAMPERS

INLET BOXES AND INLET-BOX DAMPERS INLET BOXES AND INLET-BOX DAMPERS Available on these Arrangement 1, 4, 8, 9, 9F, and 10 fans: GENERAL PURPOSE FANS ACOUSTAFOIL/PLR FANS CLASS IV FANS AF FANS RTS FANS GI FANS HPBC FANS BC FANS BCPB FANS

More information

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index

SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index SHELDONS ENGINEERING Inc. Sheldons Engineering Product Index www.sheldonsengineering.com SQUARE BODY RADIAL BLADE CENTRIFUGAL FAN D6900 GENERAL SPECIFICATION. The centrifugal fan shall be designed and

More information

The Industrial Choice. BACKWARD INCLINED FANS. Model CB-SW / CB-DW

The Industrial Choice. BACKWARD INCLINED FANS. Model CB-SW / CB-DW The Industrial Choice. BACWARD INCLINED FANS odel CB-SW / CB-DW CATALO 720 June 2013 CATALO 300 April 2012 Backward Inclined Fans odels CB-SW CB-DW This catalog features model CB non-overloading centrifugal

More information

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall Centrifugal Exhaust s Series C Roof Upblast and Sidewall April 28 Series C - Spun Aluminum Roof Upblast and Sidewall Centrifugal Exhaust s When you buy a Greenheck Series C model, you receive a fan with

More information