@Perkins. Technical Data. 1106D-E66TAG3 159, rev/min. 1100D Series. ElectropaK

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "@Perkins. Technical Data. 1106D-E66TAG3 159, rev/min. 1100D Series. ElectropaK"

Transcription

1 Technical Data 1100D Series ElectropaK Basic technical data Number of cylinders Cylinder arrangement In-Line Cycle Strokes Induction system Turbocharged and Air Charge Cooled Combustion system Direct Injection Diesel Compression ratio ,2:1 Bore mm (4.1 in) Stroke mm (5.0 in) Cubic capacity ,6 litres (402.8 in³) Direction of rotation Clockwise Firing order Estimated total weight -dry kg (1737 lb) -wet kg (1812 lb) Overall dimensions -height ,4 mm (44.9 in) -length (air cleaner fitted) ,3 mm (68.0 in) -width ,8 mm (30.7 in) Moments of inertia Engine rotational components ,27 kg m² Flywheel ,31 kg 1106D-E66TAG3 159, rev/min Centre of gravity (wet) Forward from rear of block ,3 mm (18.8 in) Above crankshaft centre line ,3 mm (6.9 in) Offset to RHS of crankshaft centre line ,0 mm (0.66 in) Performance Note: All data based on operation to ISO and ISO 3046/1 standard reference conditions. Speed variation at constant load ± 3% Cyclic irregularity at 110% stand-by power rev/min ,023 Test conditions -air temperature C (77 F) -barometric pressure kpa (29.5 in hg) -relative humidity ,5 % Sound level Average sound pressure level 100% Prime Power load for -ElectropaK at 1 metre ,2 db(a) All ratings certified to within ± 3% If the engine is to operate in ambient conditions other than those of the test conditions, suitable adjustments must be made for these changes. For full details, contact Perkins Technical Service Department. General installation Type of operation and application Designation Units Prime Standby 60Hz Gross engine power kwb (bhp) 154,4 (207.1) 171,4 (229.9) Brake mean effective pressure kpa (lbf/in²) 1560,0 (226.3) 1731,0 (251.1) Mean piston speed m/s (ft/s) 7,62 (25.0) ElectropaK net engine power kwm (bhp) (191.0) 159,4 (213.8) Engine coolant flow (against 35 kpa restriction) l/min (UK gal/min) 170,0 (37.4) Combustion air flow (at STP) m³/min (ft³/min) 12,4 (437.9) 12,7 (448.5) Exhaust gas flow (max) m³/min (ft³/min) 29,5 (1041.8) 30,7 (1084.2) Exhaust gas temperature (max) in manifold (after turbocharger) C ( F) 455,2 (851.4) 469,0 (876.2) Net engine thermal efficiency % 36,0 37,0 kwe 135,0 150,0 Typical genset electrical output (0.8pf 25 C) kva 169,0 188,0 Regenerative Power (estimated) kw (bhp) 14,9 (20.0) Assumed alternator efficiency % 92,2 91,8 Energy balance kwt (bhp) 400,9 (537.6) 435,9 (584.6) Power in fuel (fuel heat of combustion) Btu/min 22819, ,3 kwm (bhp) 12,0 (16.1) Power to cooling fan Btu/min 683,0 kwt (bhp) 74,2 (99.5) 80,1 (107.4) Power to coolant and lubricating oil Btu/min 4223,4 4559,3 kwt (bhp) 127,3 (170.7) 135,9 (182.2) Power to exhaust Btu/min 7245,9 7735,4 kwt (bhp) 32,5 (43.6) 35,0 (46.9) Energy to charge coolers Btu/min 1849,9 1992,2 kwt (bhp) 12,4 (16.6) 13,5 (18.1) Power to radiation Btu/min 705,8 768,4

2 225,5 250,4 233, ,2 88,9 225,5 242,3 1140,4 OVERALL DIMENSION 384,1 FUEL INLET 394,6 494 CUSTOMER BUSBAR CONNECTION 1106D-E66TAG3 - Left side view 1310,6 1728,3 OVERALL DIMENSION 491,9 FUEL INLET 170,3 Ø ,1 707, BREATHER OUTLET 390,5 499,6 585, ,6 47,6 156,4 408,2 Ø M12x1,75x24

3 263,54 876,8 1106D-E66TAG3 - Front view 272,8 779,8 OVERALL DIMENSION 102,3 Z 481,1 79, TO FRONT Ø 21.0 CUSTOMER MOUNTING HOLE TO FRONT Ø 21.0 CUSTOMER MOUNTING HOLE 376 Z

4 233,4 76,2 88, ,6 584,4 745,5 1106D-E66TAG3 - Right side view 4-M12x1,75x24 275,2 201,5 47,6 55,6 222, , ,4 - TO Ø 21,0 CUSTOMER MOUNTING HOLES

5 200 FUEL RETURN TO TANK Ø 281,7 1106D-E66TAG3 - Rear view 356,9 84 Z 157,1 140, ,9 FUEL RETURN TO TANK 238,1 238,1 392,5 12-M10x1,5x20 EQUI-SPACED ON 428,63 P.C.D Z

6 270,2 306,3 ALTERNATOR 203,7 31,5 278,7 1106D-E66TAG3 - Plan view W ø ,5 672,6 547,9 EHAUST OUTLET M10x1,5 THRU EQUISPACED ON 104,8 P.C.D 827,5 44 W CUSTOMER BUSBAR CONNECTION

7 Cooling system Cooling pack -overall weight (wet) kg -overall face area mm² -width mm -height mm Radiator Face area mm² Number of rows and materials rows, Aluminium Matrix density and material fins per inch, Aluminium Width of matrix mm (17.3 in) Height of matrix mm (31.1 in) Pressure cap setting (min) kpa (14.5 lb/in²) Charge cooler Face area mm² Number of rows and materials rows, Aluminium Matrix density and material fins per inch, Aluminium Width of matrix mm Height of matrix mm Fan Diameter mm (27 in) Drive ratio Number of blades Material Nylon Type Pusher Air 1800 rev/min ,8 m³/min Coolant Total system capacity litres System drawdown capacity % Engine capacity ,5 litres Maximum top tank temperature C (233.6 F) Temperature rise across engine (max, rating dependent) ,6 to 7,0 C (43.9 to 44.6 F) Max permissible external system resistance kpa (5.1 lbf/in²) Thermostat operation range to 95 C (179.6 to 203 F) Shutdown switch setting C (244.4 F) Coolant pump method of drive gears Coolant pump flow (against 35 kpa restriction) litres/min Recommended coolant immersion heater rating (minimum) ,75 kw Recommended coolant bs , ASTM D3306 and ELC coolants to 1E1966 Cold start recommendations Minimum required cranking speed over TDC rev/min Temperature Range 5 to -10 C Temperature Range -10 to -20 C Temperature Range -20 to -25 C Battery capacity is defined by the 20 hour rate If a change to a low viscosity oil is made, the cranking torque necessary at low ambient temperatures is much reduced. The starting equipment has been selected to take advantage of this. It is important to change to the appropriate multigrade oil in anticipation of operating in low ambient temperatures Breakaway current is dependent on battery capacity available. Cables should be capable of handling the transient current which may be up to double the steady cranking current. Exhaust system Oil: Starter: Battery: Max breakaway current: Cranking current: Aids: Minimum mean cranking speed: Oil: Starter: Battery: Max breakaway current: Cranking current: Aids: Minimum mean cranking speed: Oil: Starter: Battery: Max breakaway current: Cranking current: Aids: Minimum mean cranking speed: 15W40 29MT 1x 900CCA 867 amps 404 (560 max) amps Glowplugs 107 rev/min 10W40 29MT 2x 770 CCA 984 amps 496 (683 max) amps Glowplugs 100 rev/min 5W40 29MT 2 x770 CCA 984 amps 496 (683 max) amps Glowplugs 100 rev/min Maximum back 1800 rev/min ,0 kpa (4.4 in Hg) Exhaust outlet, internal diameter mm (3.5 in) Electrical system Alternator Denso A127i Alternator voltage volts Alternator output amps Starter MT Starter motor voltage volts Starter motor power ,3 kw Number of teeth on the flywheel Pull-in current of starter motor -25 C max (1) amps Hold-in current of starter motor -25 C max (1) amps Engine stop method via ECM 1 All leads to rated at 10 amps minimum

8 1100D Series 1106D-E66TAG3 Fuel system Injection components Injector Electronic Fuel pump CR200 Fuel priming Priming pump type manual / Electronic Maximum priming time seconds Fuel feed Maximum fuel flow litres/min Maximum suction head at engine fuel pump inlet kpa Maximum static pressure head kpa Fuel temperature at engine fuel pump inlet C (176 F) Tolerance on fuel consumption % Fuel specification Fuel standard BS2869, 1998 Class A2 or BS EN590 Fuel consumption Load Induction system Maximum air intake restriction -clean filter kpa (in H 2 O) -dirty filter kpa (in H 2 O) -air filter type Paper Element Lubrication system Maximum total system oil capacity litres (34.9 UK pints) Minimum oil capacity in sump litres (26.4 UK pints) Maximum oil capacity in sump litres (32.8 UK pints) Maximum engine operating angles - front up, front down, right side, left side Sump drain plug tapping size /4-16 UNF Shutdown switch setting (where fitted) ECM controlled Lubricating oil -relief valve opening pressure kpa (62.4 lbf/in²) -pressure at maximum speed kpa (65.3 lbf/in²) -maximum continuous oil temperature (in rail) C -oil consumption at full load (% of fuel) < Type of Operation and Application 60Hz Prime All information in the document is substantially correct at the time of printing but may be subsequently altered by the company. 60Hz Standby 100% g/kwhr (l/hr) 218,1 (40.1) 212,1 (43.3) 75% g/kwhr (l/hr) 229,0 (31.6) 225,6 (34.5) 50% g/kwhr (l/hr) 245,4 (23.4) 241,5 (24.6) 25% g/kwhr (l/hr) 269,5 (9.2) 271,4 (13.8) Perkins Engines Company Limited Peterborough PE1 5NA United Kingdom Telephone +44 (0) Fax +44 (0) Distributed by Recommended SAE viscosity A multigrade oil must be used which conforms to API-CH-4/CI4. 0W 5W20 10W30 15W40 20W o oc F W1355 Mountings Maximum static bending moment at -rear face of block Nm (833 lbf ft) Maximum permissable overhung load on the flywheel refer to the applications department Maximum bending moment (in shock) at rear face -of flywheel housing ± 3000 Nm Load acceptance (cold engine) The below complies with the requirements of classification 3 and 4 of ISO and G2 operating limits stated in ISO Initial load application when engine reaches rated speed (15 seconds maximum after engine starts to crank) Descriptor Units 1800 rev/min (60 Hz) % of Prime Power % 55 Load kw (kwe) 85 (74.25) Transient frequency deviation % -10 Frequency recovery seconds 5 The above figures were obtained under the following test conditions: -engine block temperature C -alternator ,8% -minimum ambient temperature C -governing mode Isochronous -typical alternator inertia kgm² All tests were conducted using an engine which was installed and serviced to Perkins Engines Company Limited recommendations. 30 Ambient temperarture 40 No. TPD1545E, Issue 3. Perkins Engines Company Limited. Publication

@Perkins. Technical Data. 192, rev/min. ElectropaK

@Perkins. Technical Data. 192, rev/min. ElectropaK Technical Data 1100D Series ElectropaK @Perkins 1106D-E66TAG4 192,3 kwm @ 1800 rev/min Basic technical data Number of cylinders..................................................... 6 Cylinder arrangement............................................

More information

@Perkins. Technical Data Series 1103C-33TG3. Performance. Basic technical data. Test conditions. Total weight (fan to flywheel)) Sound level

@Perkins. Technical Data Series 1103C-33TG3. Performance. Basic technical data. Test conditions. Total weight (fan to flywheel)) Sound level Technical Data @Perkins 1100 Series 1103C-33TG3 Diesel engine - Electropak 45,6 kwm @ 1500 rev/min Basic technical data Number of cylinders.................................................... 3 Cylinder

More information

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK Technical Data @Perkins 400 Series 403D-11G ElectropaK Basic technical data Number of cylinders.................................................... 3 Cylinder arrangement....................................

More information

Technical Data Series 1204E-E44TA. Basic technical data. Performance

Technical Data Series 1204E-E44TA. Basic technical data. Performance Technical Data 1200 Series 1204E-E44TA Industrial Open Power Unit (IOPU) 74.5 kw @ 2200 Basic technical data Number of cylinders.....................................................4 Cylinder arrangement...................................

More information

Technical Data Series TWG4A. Basic technical data. Cyclic irregularity For engine/flywheel maximum... 1:752

Technical Data Series TWG4A. Basic technical data. Cyclic irregularity For engine/flywheel maximum... 1:752 Technical Data 4000 Series 4012-46TWG4A Diesel Engine - ElectropaK 1500 rev/min Basic technical data Number of cylinders................................................... 12 Cylinder arrangement..........................................

More information

Technical Data 404D-22

Technical Data 404D-22 Technical Data 404D-22 IOPU Basic technical data Number of cylinders..................................................... 4 Cylinder arrangement....................................verticle in line Cycle............................................................

More information

400 Series 404A-22G1 ElectropaK 20.3 kwm / rpm

400 Series 404A-22G1 ElectropaK 20.3 kwm / rpm The Perkins 400 Series engine family continues to set new standards in the compact engine market. Developed alongside customers to fulfill their needs in the generator set, compressor, agricultural and

More information

Curve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled

Curve Number: FR Engine Critical Parts List: CPL 2893 Date: 19Jun00. Aspiration : Turbocharged and Aftercooled Curve Number: FR-90766 Engine Critical Parts List: CPL 2893 Date: 19Jun00 Displacement : 5.88 litre (359.0 in 3 ) Bore : 102 mm (4.02 in.) Stroke : 120 mm (4.72 in.) No. of Cylinders : 6 Aspiration : Turbocharged

More information

GRUPO ELECTROGENO 150 KVA

GRUPO ELECTROGENO 150 KVA GRUPO ELECTROGENO 150 KVA 1.- Características Técnicas del Motor. Modelo Sistema de refrigeración Sistema de Admisión Cilindros Sistema Eléctrico Combustible Gobernador CUMMINS Radiador incorporado Filtro

More information

Technical data TAD740GE

Technical data TAD740GE Technical data TAD740GE General In-line four stroke diesel engine with direct injection Turbo charged and air to air intercooled Rotation direction, anti-clockwise viewed towards flywheel Number of cylinders

More information

1100 Series 1104D-E44TG1 Diesel Engine ElectropaK 71.8 kwm (96 hp) net standby 1800 rpm

1100 Series 1104D-E44TG1 Diesel Engine ElectropaK 71.8 kwm (96 hp) net standby 1800 rpm The Perkins 1104D-E44TG ElectropaKs are the latest addition to the 1100 Series Electric Power line-up. Offering improved power density from a compact package, these ElectropaKs build on Perkins reputation

More information

144 5, ,50 Compression ratio 16,5:1 Dry weight. Engine only, excluding cooling system GenPac. Engine only, excluding cooling system GenPac

144 5, ,50 Compression ratio 16,5:1 Dry weight. Engine only, excluding cooling system GenPac. Engine only, excluding cooling system GenPac General Inline four stroke diesel engine with direct injection. Rotation direction, anticlockwise viewed towards flywheel. Turbocharged Number of cylinders 6 Displacement, total Firing order in 3 16,12

More information

Cummins Techical Operations ENGINE MODEL 6CTA8.3-C240 CURVE & DATASHEET FR91499 Rev00 Jun/2006 CUMMINS engine 6CTA8.3-C240

Cummins Techical Operations ENGINE MODEL 6CTA8.3-C240 CURVE & DATASHEET FR91499 Rev00 Jun/2006 CUMMINS engine 6CTA8.3-C240 Cummins Rev Engine Performance Curve Basic Engine Model: Curve Number: 6CTA8.3-C240 Pg. No : Engine Family: CPL Code: Date: 40399 Displacement: 8.3 L Aspiration: Turbocharged & Aftercooled Bore: 114 mm

More information

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs. In the world of power generation success

More information

1000 Series 6TWGM Marine Auxiliary Engine kw (195.7 hp) gross prime 1800 rpm

1000 Series 6TWGM Marine Auxiliary Engine kw (195.7 hp) gross prime 1800 rpm Based on Perkins universally acclaimed 1000 Series and renowned throughout the power generation industry for its superior performance and reliability. The Perkins 6TWGM is a turbocharged, charge air-cooled,

More information

1100 Series 1104D-44TG3 Diesel Engine ElectropaK 54 kwm (72 hp) net prime 1500 rpm 59 kwm (79 hp) net standby 1500 rpm

1100 Series 1104D-44TG3 Diesel Engine ElectropaK 54 kwm (72 hp) net prime 1500 rpm 59 kwm (79 hp) net standby 1500 rpm The Perkins 1104D turbocharged ElectropaKs are the latest addition to the 1100 Series ElectropaK range. Perkins has developed this engine in line with our customer s needs by providing the options of either

More information

1100 Series 4.4TW2GM Marine Auxiliary Engine kw (143.2 hp) gross prime 1800 rpm

1100 Series 4.4TW2GM Marine Auxiliary Engine kw (143.2 hp) gross prime 1800 rpm Building upon Perkins proven reputation within the marine power generation industry. The 4.4 Series range of Marine Auxiliary engines now fit even closer to the needs of their customers. In the world of

More information

Dongfeng Cummins Techical Operations

Dongfeng Cummins Techical Operations Dongfeng Cummins Techical Operations : Curve and Datasheet:FR20322 Rev01 Date of Issue: 2010/03 450 Dongfeng Cummins Co.,Ltd Generator Performance Data FR20322 @ 1500RPM & 1800RPM : CPL: 3690 Compression

More information

MITSUBISHI DIESEL ENGINE IFM NO. JN (1/6) TECHNICAL INFORMATION DATE Aug. 8, 2002

MITSUBISHI DIESEL ENGINE IFM NO. JN (1/6) TECHNICAL INFORMATION DATE Aug. 8, 2002 DIESEL ENGINE IFM NO. JN02411-011(1/6) TECHNICAL INFORMATION DATE Aug. 8, 2002 TITLE Specification Sheets of S6U-MPTK Engine (IMO Certified Engine) Specification Sheets of S6U-MPTK Engine that is satisfied

More information

See Note. 100% of rated load

See Note. 100% of rated load Generator set data sheet 1160 kw Continuous Model: Frequency: C1160 N5C 50 Hz Fuel type: Natural gas MI 78 + Emissions NOx: 500 mg/nm 3 LT water inlet temp: HT water outlet temp: 50 C (122 F) 95 C (203

More information

400 Series 403D-15 Industrial Open Power Unit 24.2 kw / 32.5 hp

400 Series 403D-15 Industrial Open Power Unit 24.2 kw / 32.5 hp The Perkins 400 Series engine family continues to set new standards in the compact engine market. Developed alongside customers to fulfil their needs in the construction, materials handling, agricultural/turf,

More information

S16U-TA MITSUBISHI DIESEL ENGINES

S16U-TA MITSUBISHI DIESEL ENGINES S16U-TA GENERAL ENGINE DATA Type... 4-Cycle, Water Cooled Aspiration... Turbo-Carged, After Cooler (Jacket Water to Cooler) Cylinder Arrangement... 60 V No. of Cylinders... 16 Bore mm (in.)... 240 (9.45)

More information

1100 Series 1106A-70TG1 Diesel Engine ElectropaK 118 kwm (158 hp) net prime 1500 rpm 131 kwm (176 hp) net standby 1500 rpm

1100 Series 1106A-70TG1 Diesel Engine ElectropaK 118 kwm (158 hp) net prime 1500 rpm 131 kwm (176 hp) net standby 1500 rpm Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs. In the world of power generation success

More information

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 Engine Performance Curve Basic Engine Model: Curve Number: 6CTA8.3 FR2-9626 Engine Family: CPL Code: Date: D41 1366 18Apr95 13 Displacement: 504.5

More information

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me WGP-C30/S CUMMINS Series Rotate speed governor: Mechanical governor Excitation system: Self excited, SHUNT A.V.R model: AS480 Emergency stop switch ATS (automatic transfer switch) receptacle 1x12V sealed

More information

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with SHENZHEN FUDIANKANG ENERGY CO., LTD Web: Email: info@fdkenergy.com DATA SHEET DIESEL GENERATOR 176KW MODEL#FDK-P176/H1 50HZ/1500RPM PERKINS MODEL: 1106A-70TAG4 General Features: All qualified generator

More information

Technical data TAD1642GE

Technical data TAD1642GE General Inle four stroke diesel enge with direct jection. Rotation direction, anticlockwise viewed towards flywheel. Turbocharged Number of cylders 6 Displacement, total Firg order litre 3 16,12 983,7

More information

DIESEL GENERATOR SETS

DIESEL GENERATOR SETS DIESEL GENERATOR SETS STANDBY Model Standby Prime kw (kva) kw (kva) D25-6 25 (31.3) 22.8 (28.5) D25-6S 25 (25) 22.5 (22.5) D30-8 30 (37.5) 27 (33.8) D30-6S 30 (30) 27 (27) Tier 2 EPA Approved, Emissions

More information

400 Series 422TGM Marine Auxiliary Engine 30.3 kw (40.6 hp) gross prime 1800 rpm

400 Series 422TGM Marine Auxiliary Engine 30.3 kw (40.6 hp) gross prime 1800 rpm Based on the Perkin 400 Series, the 422TGM provides compact power from a robust family of 2, 3 and 4 cylinder diesel engines, designed to meet today s uncompromising demands within the power generation

More information

Bore and stroke 84 x 100 mm 3.3 x 3.9 in Displacement 2.2 litres 135 in 3

Bore and stroke 84 x 100 mm 3.3 x 3.9 in Displacement 2.2 litres 135 in 3 The Syncro 2.2 engine is the newest member of the highly successful Perkins 400 Series and has been designed to help our customers meet current emissions standards in North America. The engine is a 4-cylinder,,

More information

*CPL1858 Non Certified **CPL1937 CARB Certified

*CPL1858 Non Certified **CPL1937 CARB Certified CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: -240G Engine Family: CPL Code: D43 1858 * / 1937** Curve Number: FR-2304 Date: 12Jul94 1 Displacement:

More information

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER

TECHNICAL DATA DEPT. CERTIFIED WITHIN 5% CHIEF ENGINEER CUMMINS ENGINE COMPANY, INC Columbus, Indiana 47202-3005 ENGINE PERFORMANCE CURVE Basic Engine Model: Curve Number: -370E FR-1811 Engine Family: CPL Code: Date: D09 1807 12Aug93 55 Displacement: 855 in.

More information

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T I N G S E T GEH250 (3-Phase) 50 HZ STANDBY PRIME 250 kva / 200 kw 230 kva / 184 kw FEATURES GENERATING SET Complete system designed and built at ISO9001 certified facility Factory

More information

UK Purchased. TRWA Rotation* 929 (2053) Compression Ratio. 15.7:1 Displacement l (cu. in.)

UK Purchased. TRWA Rotation* 929 (2053) Compression Ratio. 15.7:1 Displacement l (cu. in.) MODELS FIRE PUMP ENGINES JW6H-AP30 JW6H-AP40 JW6H-AP50 JW6H-AP60 UK Purchased APSAD ENGINE MODELS GROSS POWER RATINGS KW/BHP JW6H MODEL AP30 AP40 AP50 AP60 217 238 246 295 1760 291 319 330 396 218 239

More information

Section 5. Engine data. Engines for power generation. 12-series. Contents. Industrial & Marine Engines. Edition 2007:1

Section 5. Engine data. Engines for power generation. 12-series. Contents. Industrial & Marine Engines. Edition 2007:1 Edition 2007:1 Industrial & Marine Engines Section 5 Engine data Engines for power generation Contents General information... 3 Engine program... 4 Basic data... 6 Technical data and cooling equipment

More information

4000 Series 4012TESI Spark Ignited Gas Engine rpm

4000 Series 4012TESI Spark Ignited Gas Engine rpm Designed in advance of today s uncompromising demands within the gas power generation industry, the Perkins 4000 Series family of 6, 8, 12 and 16 cylinder spark ignition gas engines offers superior performance,

More information

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET DP03000D5S DIESEL GENERATOR SET DP03000D5S 380V 11 kv/50 Hz/Prime/TA-Luft Optimized MTU 20V4000G63L/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS // Benefits

More information

C18 ACERT Fire Pump Tier bkw/ rpm

C18 ACERT Fire Pump Tier bkw/ rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

C18 ACERT Fire Pump Tier bkw/ rpm

C18 ACERT Fire Pump Tier bkw/ rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts Four levels of controls to meet individual customer needs: - EMCP II offers digital monitoring, metering, and protection - EMCP II+ offers EMCP II features plus full-featured power metering and protective

More information

Technical data TAD1641VE

Technical data TAD1641VE General Inle four stroke diesel enge with direct jection. Rotation direction, anticlockwise viewed towards flywheel Number of cylders 6 Displacement, total Firg order s 3 16,12 984 153624 Bore Stroke 144

More information

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 16V2000 DS1000 DIESEL GENERATOR SET MTU 16V2000 DS1000 Prime Power: 910 KVA 380V - 415V/50 Hz/Air Charge Air Cooling Optional equipment and finishing shown. Standard may vary. Product Highlights // Benefits - Low fuel

More information

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET STANDBY 350 ekw 437.5 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 1000 ekw 1250 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts C13 STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts 01 DIESEL GENERATOR SET STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts Image shown may not reflect actual package. Caterpillar is leading the power

More information

Marine Propulsion 3126

Marine Propulsion 3126 Marine Propulsion 3126 SPECIFICATIONS 22 bkw @ rpm bhp @ rpm Shown with Accessory Equipment STANDARD ENGINE EQUIPMENT Air Inlet System 12V air inlet heater, sea water aftercooler, air cleaner/fumes disposal,

More information

3056 MARINE PROPULSION

3056 MARINE PROPULSION 056 MARINE PROPULSION 9 bkw (125 bhp) Image may not reflect actual engine SPECIFICATIONS I-6, -Stroke-Cycle-Diesel Bore... 100 mm (.9 in.) Stroke... 127 mm (5.0 in.) Displacement.................. 6 L

More information

KVA KW KVA KW

KVA KW KVA KW ژنراتور : MTU موتور ديزل : MTU Standby Prime KVA KW KVA KW 1100 880 1000 800 ديزل ژنراتور ABYARAN Copyright 2014 - All Rights Reserved 1 موتور ديزل توليد كننده Manufacturer MTU مدل Model 16V2000 DS1100

More information

D I E S E L G E N E R A T O R S E T S

D I E S E L G E N E R A T O R S E T S D I E S E G E N E R A T O R S E T S STANDBY PRIME 60 Hz 25-30 kw 22.5-27 kw Model kw (kva) kw (kva) D25-6 25 (31.3) 22.8 (28.5) D25-6S 25 (25) 22.5 (22.5) D30-8 30 (37.5) 27 (33.8) D30-6S 30 (30) 27 (27)

More information

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 20V4000 DS2650 DIESEL GENERATOR SET MTU 20V4000 DS2650 380V 11 kv/50 Hz/Prime Power/TA-Luft Optimized MTU 20V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary. PRODUCT HIGHLIGHTS

More information

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 400 ekw 500 kva Image shown may not reflect actual package. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

ژنراتور : Meccalte موتور دیزل : IVECO KW KVA KW KVA

ژنراتور : Meccalte موتور دیزل : IVECO KW KVA KW KVA ژنراتور : Meccalte موتور دیزل : IVECO Standby Prime KW KVA KW KVA 66 52.8 6 48 دیزل ژنراتور ABYARAN Copyright 214 - All Rights Reserved 1 موتور دیزل تولید کننده تیپ تعداد سیلندر ها آرایش سیلندر ها جا به

More information

Diesel Generator Set Model DFBF 60 Hz

Diesel Generator Set Model DFBF 60 Hz Diesel Generator Set Model DFBF 60 Hz 275 kw, 344 kva Standby 250 kw, 313 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation system

More information

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts DIESEL GENERATOR SET STANDBY 250 ekw 313 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life! Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 550KVA Generator Set Specification. Ultra Silent, Extended Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM

More information

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 1200 ekw 1500 kva Image shown may not reflect actual package. Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 400 ekw 500 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Mitsubishi Diesel Engine Generators (Year 2008) Model: S12R-PTA (1250 kva, 3300V, 50Hz)

Mitsubishi Diesel Engine Generators (Year 2008) Model: S12R-PTA (1250 kva, 3300V, 50Hz) Mitsubishi Diesel Engine Generators (Year 2008) Model: S12R-PTA (1250 kva, 3300V, 50Hz) 1. Condition Engine starts within 40 seconds after Automatic Start ordered. Lubricating Oil must be Operating Condition:

More information

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts DIESEL GENERATOR SET STANDBY 600 ekw 750 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Diesel Generator Set Model DFHB 60 Hz

Diesel Generator Set Model DFHB 60 Hz Diesel Generator Set Model DFHB 60 Hz 800 kw, 1000 kva Standby 725 kw, 906 kva Prime Description The Cummins Power Generation DF-series commercial generator set is a fully integrated power generation system

More information

STANDBY 4000 ekw 5000 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 4000 ekw 5000 kva 60 Hz 1800 rpm 4160 Volts DIESEL FEATURES GENERATOR SET STANDBY 4000 ekw 5000 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched

More information

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability,

More information

MARINE PROPULSION SPECIFICATIONS STANDARD ENGINE EQUIPMENT. 320 mhp (315 bhp) 235 bkw

MARINE PROPULSION SPECIFICATIONS STANDARD ENGINE EQUIPMENT. 320 mhp (315 bhp) 235 bkw 320 mhp (315 bhp) 235 bkw Image shown may not reflect actual SPECIFICATIONS I-6, 4-Stroke-Cycle-Diesel Emissions...IMO Displacement... 7.2 L (442 cu in) Rated Speed...2400 Bore... 110 mm (4.33 in) Stroke...

More information

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts C18 STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts 01 DIESEL GENERATOR SET STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts Image shown may not reflect actual package. Caterpillar is leading the power

More information

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH Voltage kva 380-415 400 Prime* kw 320 kva 440 Standby* kw 352 Ampere 557 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model

More information

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards) Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications

More information

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET STANDBY 1750 ekw 2188 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

3508 Industrial Engine

3508 Industrial Engine FEATURES Image shown may not reflect actual engine CAT ENGINE SPECIFICATIONS V-8, 4-Stroke-Cycle Diesel Bore...170.0 mm (6.69 in) Stroke...190.0 mm (7.48 in) Displacement... 34.53 L (2,107.15 in 3 ) Aspiration...Turbocharged

More information

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability,

More information

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 600 ekw 750 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Prime* Standby* Voltage kva kw kva kw 380-415 12 9,6 14 11,2 Ampere 17 Prime Rating Standby Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model

More information

- This symbol on the nameplate means the product is 6CTA8.3-F LISTED AGENCY RATINGS

- This symbol on the nameplate means the product is 6CTA8.3-F LISTED AGENCY RATINGS 6CTA8.3-F FIRE PUMP ENGINE SPECIFICATIONS Four Stroke Cycle, Turbocharged-Aftercooled, In-Line, 6 Cylinder Diesel Engine,'-- Bore and Stroke 4.49 x 5.32 in. (1 14x135 mm) LISTED AGENCY RATINGS 300 HP 8

More information

3516 Industrial Engine

3516 Industrial Engine CAT ENGINE SPECIFICATIONS V-16, 4-Stroke-Cycle Diesel Bore...170.0 mm (6.69 in) Stroke...190.0 mm (7.48 in) Displacement... 69.06 L (4,214.3 in 3 ) Aspiration...Turbocharged / Aftercooled Compression Ratio...13.0:1

More information

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 508 ekw 635 kva Image shown may not reflect actual package. Caterpillar å is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS1650 DIESEL GENERATOR SET MTU 12V4000 DS1650 380V 11 kv/50 Hz/Grid Stability Power/Fuel Consumption Optimized MTU 12V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard may vary.

More information

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 292 ekw 365 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts Diesel FEATURES Generator Set PRIME 800 ekw 1000 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched

More information

Natural gas engine E 0836 LE 202 Technical data

Natural gas engine E 0836 LE 202 Technical data Page 1 Principle: No of cylinders : Supercharging: Mixture cooling: Engine cooling : Lubrication : Spark plugs: Starter motor: 4-stroke Otto gas engine 6 in line Exhaust turbocharger with water-cooled

More information

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

STANDBY 200 ekw 250 kva

STANDBY 200 ekw 250 kva DIESEL GENERATOR SET STANDBY 200 ekw 250 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered Image shown may not reflect actual package reliability, and cost-effectiveness.

More information

Generator Set Specifications 480 ekw 600 KVA

Generator Set Specifications 480 ekw 600 KVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Picture shown may not reflect

More information

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET CONTINUOUS 728 ekw 910 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and

More information

Generator Set Specifications 100 ekw (125 kva)

Generator Set Specifications 100 ekw (125 kva) Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not refl ect

More information

DIESEL FEATURES GENERATOR SET

DIESEL FEATURES GENERATOR SET IE DIESEL FEATURES GENERATOR SET Image shown may not reflect actual package Standby 2200 ekw 2750 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver

More information

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH Voltage 380-415 Prime* Standby* kva kw kva kw 1844 1475 2030 1624 Ampere 2568 Prime Rating Applicable for supplying continuous electrical power at variable load for unlimited hours. This model can supply

More information

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

1100 Series 1103D-33 Industrial 36.9 kw / 49.5 hp

1100 Series 1103D-33 Industrial 36.9 kw / 49.5 hp With the success of the 1100 Series, single platform engines, Perkins have taken development further with the introduction of the new 1100D range. The 1103D engine is a unique mechanical power solution

More information

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

GEN SET PERFORMANCE DATA [HCC PREFIX]

GEN SET PERFORMANCE DATA [HCC PREFIX] SET PERFORMANCE DATA [HCC PREFIX] Sales Model: 3306 SINA Combustion: SI Aspr: NA Engine Power: 85 W/O F 126 HP Manifold Type: WET Speed: 1,800 RPM Governor Type: PSG After Cooler: After Cooler Temp(F):

More information

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2250 DIESEL GENERATOR SET MTU 16V4000 DS2250 380V 11 kv/50 Hz/Data Center Continuous Power/Fuel Consumption Optimized MTU 16V4000G23/Water Charge Air Cooling Optional equipment and finishing shown. Standard

More information

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073 including r installations. Backed by the worldwide l provide the reliabi 2 2750 400 Prime LEHE1073 an. These generators feature permanent magnet alternators which provide 300% short circuit sustaining

More information

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET STANDBY 900 ekw 1125 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Perkins Peregrine EDi and 1300 Series EDi Models WK to WS

Perkins Peregrine EDi and 1300 Series EDi Models WK to WS Perkins Peregrine EDi and 300 Series EDi Models WK to WS WORKSHOP MANUAL Peregrine 6 cylinder turbocharged diesel engines with electronic management system for automotive applications 300 Series 6 cylinder

More information

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET PRIME 220 ekw 275 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

C32 ACERT Industrial Engine Tier bkw/ rpm

C32 ACERT Industrial Engine Tier bkw/ rpm CAT ENGINE SPECIFICATIONS Vee 12 Cylinder, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...162.0 mm (6.38 in) Displacement... 32.1 L (1,958.86 in 3 ) Aspiration...Turbocharged Aftercooled Compression

More information

C Offshore Drilling Generator Set

C Offshore Drilling Generator Set C175-16 Offshore Drilling Generator Set 1833 ekw (2619 kva) 1930 bkw (2588 bhp) 60 Hz (1200 rpm) CAT GENERATOR SET SPECIFICATIONS V-16, 4-Stroke-Cycle-Diesel Emissions...IMO Tier II/EPA Marine Tier 2 Bore...

More information

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES: Standby Generators Liquid-Cooled Gaseous Engine 1 of 9 INCLUDES: Two Line LCD Tri-Lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System

More information

C18 ACERT Industrial Engine Tier 3/Stage IIIA 429 bkw/ rpm

C18 ACERT Industrial Engine Tier 3/Stage IIIA 429 bkw/ rpm CAT ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in 3 ) Aspiration...Turbocharged Aftercooled Compression Ratio...16.3:1

More information