EXPERIENCE WITH TORSIONAL VIBRATION AT A 600 MW TG UNIT

Size: px
Start display at page:

Download "EXPERIENCE WITH TORSIONAL VIBRATION AT A 600 MW TG UNIT"

Transcription

1 EXPERIENCE WITH TORSIONAL VIBRATION AT A 600 MW TG UNIT Jurek Ferleger, Turbine Specialist/Consultant Presented at EPRI Turbine Generator User s Group Meeting, Chicago, Il, August 2014 ABSTRACT Turbine-generator power trains employ multiple large rotors. The rotors are connected through relatively flexible shafts and couplings. The turbine rotors feature a number of bladed discs that have substantial torsional inertia. The generator rotor also contributes substantially to torsional inertia and stiffness of the power train. Consequently, a large turbine-generator shaftline exhibits a substantial number of relatively low natural frequencies. The transverse rotor vibrations can be minimized with precision balancing, and can be measured with standard plant equipment. However, the torsional oscillations, characterized by the angular vibratory twisting of the rotor about its centerline, which are superimposed on its angular velocity, cannot be readily detected. Furthermore, damping in the torsional vibrations is usually very light. Thus, substantial undetected torsional response may be present in some units. This response is of special concern if a particular torsional mode is close to the double line excitation (120 Hz in a 60 Hz electrical grid). This is because the transmission line phase imbalances and/or load imbalances may cause significant torsional excitation at twice the speed of the rotor. Equipment manufacturers attempt to avoid resonance at 120 Hz through complex analyses and testing of their units. Nevertheless, some older operating units may have a natural torsional mode close to the double line excitation. While a few units have experienced distress or even catastrophic failure due to such coincidence, other ones have long successful operating history in spite of such coincidence. This paper discusses an experience with torsional vibration issues at a fossil plant in South Central United States. The unit exhibited a torsional resonance in the vicinity of 120 Hz but has not experienced distress associated with torsional vibrations. INTRODUCTION The aforementioned 600 MW unit was designed for 1000 F and 2415 psia inlet temperature and inlet pressure, respectively. The station started commercial operation in the early 1990s. The power train consists of two Double Flow Low Pressure (DFLP) sections and a High Pressure Intermediate Pressure (HPIP) section. The axisymmetric rotating components are joined through couplings and tightly fitted coupling bolts. The DFLP rotors are also symmetric about the inlet planes, shown in red in Figure 1. The unit is equipped with a 629,000 KVA, 24,000 V hydrogen/water cooled generator. The subject unit is currently undergoing a retrofit of LP elements. During the process of composing a turbine procurement specification and bid evaluation, it was realized that the unit may have a torsional mode in the vicinity of the double line excitation. However, no distress associated with this condition has been identified during regular inspections. This paper outlines the experience of the subject unit with a torsional mode coincident with 120 Hz excitation and offers an explanation for the absence of any distress associated with this response. 1

2 LPA LPB Figure 1: Turbine Generator Mechanical Outline OUTLINE OF TG SHAFTLINE VIBRATORY CHARACTERISTICS During start up and under steady state operation, turbine rotors are subject to many complex excitations which may arise due to steam flow irregularities, rotor imbalance, electrical grid perturbances and other phenomena. The response to these excitations depends on the available damping, energy cancellation effects (further explained in the following sections), etc. These effects are different for each particular mode. Vibration of turbine rotating components can be broadly divided into the following classes: Axial or longitudinal vibrations (tension-compression of the shaft): This type of vibration is not usually of major concern to operators of large Turbine Generator (TG) sets. In an unlikely situation when longitudinal vibrations are present, these are identifiable by the thrust bearing proximity probes. Flexural vibrations: This type of response is characterized by the bending of the shaft in the transverse direction. The transverse vibrations can usually be detected by bearing vibration sensors. Large vibration must be prevented at the operating speed of the TG unit, as outlined in ISO [1] and ISO [2]. Equipment manufacturers tune the first (and second, if applicable) lateral speed at least 10% away from the operating speed of the turbine. Torsional vibrations: These vibrations are characterized by the twisting of the rotor about its centerline, superimposed on its angular velocity. Large turbine generator rotor trains exhibit many torsional vibration modes with natural frequencies below or near double frequency of the grid (120 Hz). These types of shaftline vibrations cannot be detected with standard plant monitoring equipment. The mode shapes vary from a simple twist with a node in the middle of the rotor to a complex motion with substantial last stage or penultimate stage blade participation. (For a unique blade frequency, there are a number of similar system torsional modes because of differences in blade deflection patterns at the opposite ends of the rotor, i.e. in phase, out of phase, etc.) Other shaftline torsional modes exhibit substantial generator and/or exciter twist. A measurable twist at the turbine couplings or the stubshaft may also be present. Furthermore, damping in torsional vibration modes is very low. Thus, if excitations are present, high levels of stress may be reached (however low damping also results in sharp peaks which means that small difference between an excitation and a natural frequency is sufficient to avoid resonance). Consequently, prudent design practice requires 2

3 sufficient separation between the torsional frequency and excitation frequency, as outlined in ISO [3] and Nuclear Industry Insurance ( NEIL ) Guidelines [4]. Figure 2 outlines conceptually typical torsional modes of a power train composed of HPIP rotor + 2 DFLP rotors + Generator. Similar to the flexural modes, the fundamental mode has a single node (point of zero angular displacement), the second mode has two such nodes and so on. A higher mode, likely to incorporate large participation of the last or penultimate row of blades is also shown in Figure 2. J. Ferleger May 2014 Figure 2: Conceptual Outline of Torsional modes of a power train consisting of an HPIP, DFLP, DFLP and a Generator Blade vibrations: Synchronous blade vibrations are typically illustrated on a Campbell diagram, on which the frequency of each blade mode is plotted as a function of turbine running speed (frequencies usually increase as a function of turbine speed because of the increasing stiffening effect of the centrifugal force). Each blade mode can actually be characterized as a family of modes which includes a zeroth nodal diameter mode (a.k.a. umbrella mode), 1st nodal diameter mode, second nodal diameter mode, etc as shown in Figure 3. All the subject modes, except the infinite nodal diameter mode, couple with disc frequencies. The 1 st, 2 nd, etc, nodal diameter modes can be excited when turbine speed 3

4 coincides with the 1 st or 2 nd multiple of turbine speed, respectively, usually referred to as 1 st or 2 nd harmonic. The umbrella modes, which cannot be shown on a Campbell diagram, can only be excited by electrical grid perturbances, which exert fluctuating torques on the generator. Each blade row has an umbrella mode corresponding to the 1 st mode, 2 nd mode, etc. Typically, only the two lowest umbrella modes are evaluated as a part of rotor torsional response. However, as mentioned in the previous bullet, for a large power train which includes 2 DFLPs, a number of similar umbrella modes, which correspond to the first or second blade mode, may exist. This is because, for each rotor, both an in-phase and out-ofphase umbrella modes on opposite discs in the same rotor, typically with very similar frequencies, can be excited. J. Ferleger May 2014 Figure 3: Outline of Turbine Blade Vibratory Characteristics OUTLINE OF ELECTRICAL TORSIONAL STIMULI ON TG SHAFTLINE Torsional vibrations of the turbine generator power train cannot be excited by steam flow or rotor imbalance. Torsional stimuli on the turbine generator shaftline arise due to electrical imbalances imposed on the generator rotor. Normally, a three-phase balanced supply voltage, applied to a set of symmetrical threephase windings, generates a constant-magnitude flux in the airgap of the generator. Such 4

5 flux rotates at synchronous speed around the circumference of the machine. However, during any perturbance, such as line-to-ground fault, the supply voltage or currents become unbalanced. (During an electrical imbalance, the currents in the faulted and intact phases incorporate three 60 Hz components, referred to as zero, positive and negative sequence currents.) As a result of an electrical fault, an additional flux, which matches the fundamental frequency of the system, appears in the airgap of the generator. This flux rotates in the opposite direction from the generator rotor and thus induces a voltage and body current at twice the fundamental frequency of the rotor windings. Such current is referred to as negative sequence current, designated as I 2. The larger the imbalance, the higher the I 2 component. (Under a balanced electrical load, there is a steady positive sequence current and the negative and zero sequence currents have zero value.) Positive and negative sequence currents affect the generator rotor differently. When the negative sequence current is imposed on the stator, the rotor, which rotates at 60 Hz, is subject to the magnetic field that rotates 60 Hz in the opposite direction (hence the name negative sequence current ). Therefore, the generator rotor is temporarily exposed to a 120 Hz rotating magnetic field. This introduces negative sequence currents, which tend to flow close to the surface of the rotor. Such fluctuating negative sequence currents produce fluctuating torques, which act on the generator rotor, at twice the grid frequency. While the permissible values for continous I 2 currents to be withstood by a generator without injury are contained in ANSI/IEEE C50.13, no equivalent I 2 thresholds have been published to minimize High Cycle Fatigue (HCF) damage in turbine rotating components. The frequency of the positive sequence current, which rotates in the opposite direction from the I 2 current, is 60 Hz. A change in the positive sequence current arises whenever a there is a mismatch between the electrical load demand and supply. Electrical excitation at 60 Hz can excite a rotor twisting mode which has a frequency close to 60 Hz, if the mode shape includes generator participation. However, the 60 Hz torque decreases rapidly to negligible values. Therefore, the 60 Hz stimulus disappears quickly, before any significant excitation of the rotor train occurs, and is ignored by some turbine manufacturers. The 120 Hz transient torque, on the other hand, does not decay as rapidly as the positive sequence torque. In general, it is truncated by the generator protection system. However, it may be sustained for a few cycles until the breaker protection system intervenes. Therefore, this torque can potentially result in a large transient response in the rotor train before the fault is cleared. The negative sequence current torques can become quite large during a grid transient, particularly if the grid fault is not cleared by protective relays in a timely manner. The large torques act as impulse loads on the unit and may excite many torsional modes regardless of their natural frequency. However, individual mode response depends on its excitability. For example, a torsional mode that includes in-phase generator rotor twist will be readily excited by an impulse load, whereas a mode with little or no generator participation will not be excited. In addition, a mode with a node in the middle of the generator rotor span cannot be excited by a uniform excitation force due to torque 5

6 cancellation. This effect is conceptually illustrated in Figure 4 where it can be observed that a uniform excitation force is out of phase with a mode of the rotor, i.e. half of the excitation force tends to excite this particular mode, whereas the other half of the same force tends to suppress it. Thus, a mode with a node at the middle of the generator rotor, for which the twist of each half of the generator body is equal but 180º out of phase, cannot be excited by a uniform air-gap torque acting along the length of the generator body. This is true even if the damping in the particular mode is negligible [5]. DESIGN CONSIDERATIONS Figure 4: Outline of Torque Cancellation Concept All Original Equipment Manufacturers (OEMs) impose frequency separation requirements between the electrical excitations and shaftline torsional frequencies. The specific design criteria of each OEM are proprietary and are not entirely consistent. Some manufacturers consider the double line excitation only whereas others avoid the single line excitation, as well. A number of manufacturers will allow a resonance close to the 120 Hz double line if it can be shown that the response level associated with such mode is acceptable. The recently issued ISO outlines recommended industry standards, summarized in Table 1 for the 60 Hz market. In the ISO standard, the separation requirements depend on the available frequency verification testing. In addition, some basic requirements have also been proposed by the Nuclear Electric Insurance Loss of Control Manual [4] Table 1: Summary of ISO Frequency Separation Requirements for 60 Hz Network Verification requirements Single line separation requirements Double line separation requirements Separation requirements as % None ± 3.6 Hz ± 7.2 Hz ± 6% Full-speed shop dynamic test on the generator rotor and a static test on the adjacent LP turbine rotor ± 3 Hz ± 6 Hz ± 5% Full speed shop dynamic test on the generator and the associated LP ± 2.4 Hz ± 4.8 Hz ± 4% Full-speed test carried out on the fully installed shaft system ± 2.1 Hz ± 4.2 Hz ± 3.5% Experience has showed that torsional frequency analytical models and the resultant calculations can be assumed to be accurate within ± 2%. This is a fairly typical tolerance in determining the frequency of a complex system such as a turbine rotor shaftline. A similar margin of error is often assumed in calculation of the frequency of a large turbine blade, where both bending and torsion are likely to be present. It can therefore be surmised that it is not possible to calculate the higher natural torsional frequencies accurately. However, since the resonance peaks tend to be sharp due to low system damping, the probability of the excitation frequency coinciding with the response frequency is low. Unfortunately, as outlined in the following section, the consequences 6

7 of a such a coincidence and the resultant torsional resonance, in particular at 120 Hz, can be severe. SUMMARY OF INDUSTRY EXPERIENCE The oldest reported failure due to torsional resonance occurred at Cleco Coughlin fossil plant in LP blade failures at the plant were attributed to high generator phase imbalance. Another series of events, which were attributed to torsional resonance, occurred in at Prairie Island Nuclear Plant. Three separate L-2 and L-1 blade loss incidents, which resulted in forced outages, were reported. To address the torsional resonance problem, the L-2 blade was redesigned, the disc under the L-1 blade was re-contoured and a weight was added at the turning gear location [7]. The most significant torsional event occurred in 1986 in the Far East [8]. No information that clearly identifies the cause of this incident is available in the public domain. However, it is known that a number of last stage blades were lost. The resulting significant imbalance caused large rotor vibrations which, in turn, caused the bearing caps to fail. A lubricant fire ensued. The affected unit and a sister unit were retrofitted by a competitor. Two additional torsional vibration incidents were reported in Details of these incidents have not been published. Two torsional incidents also occurred in (In one of these events, the penultimate blade failure caused a forced outage. The failure was subsequently attributed to 120 Hz torsional resonance. Addition of an inertia ring to de-tune the unit by approximately 3 Hz was recommended by the manufacturer). A complex turbine generator system may have up to 25 torsional vibration modes below the excitation frequency of 120 Hz, including several frequencies near 120 Hz [9]. Welded rotors, which are stiffer, feature fewer torsional modes in the spectrum of interest. This simplifies the process of tuning away from torsional excitations. OPERATING HISTORY OF THE AFFECTED UNIT The unit that is the subject of this paper has over 20 years of operating history. A Non Destructive Examination (NDE) was performed in No high cycle fatigue cracks, which could be attributed to torsional vibrations, were found [11]. A decision was made to replace the LP rotors for unrelated reasons. During the preparation of the procurement specification and subsequent bid evaluation, it was realized the currently operating turbine generator power train may have a torsional mode in the vicinity of 120 Hz. Although the HPIP element had been replaced by a non-oem in 2002, the retrofit is very unlikely to have affected the torsional frequency of the generator in a measurable way. Figure 5 outlines the summary of torsional frequencies provided by the manufacturer and illustrates some torsional modeshapes of interest. As it can be observed, the calculation predicts the 2nd generator mode to be in the vicinity of the 120 Hz double line excitation. 7

8 Mode Description Hz 1 System System System L-0 Bucket Out Of Phase L-0 Bucket Out Of Phase Generator Twist L-0 Bucket In Phase L-0 Bucket In Phase L-1 Out Of Phase Some modes, including the generator 1 st twisting mode, are in the range of Hz. These modes were not provided by the OEM CPLG HPIP DFLP1 DFLP2 GEN EXTR Conceptual Depiction of One of the Out-of-Phase Last Stage Blade Umbrella Modes Figure 5: Summary of the torsional modes provided by the OEM SUMMARY OF TORSIONAL TEST FINDINGS To determine a baseline vibratory characteristic of the unit before the LP retrofit, a Torsional Vibration Test was performed on the turbine generator shaftline. Three telemetry collars were secured, one each at the bearing between the two LP rotors and at the two bearings adjacent to the generator, as shown in Figure 6. (Two sets of strain gauges were attached to the shaft 180º apart at each collar [6].) The strain gauges were mounted at locations where, based on analytical predictions, the highest torsional deflection was expected in the mode of interest. The unit was tested at sub-synchronous and at synchronous speed, at various load points. The following observations were made after a detailed review of test results: Figure 6: Location of torque collars A torsional mode was detected in the vicinity of 120 Hz at the initial three test points: (1) 3000 rpm, (2) Full Speed No Load (FSNL) conditions, and (3) 10 MW load. 8

9 The subject mode was primarily detected at the bearings adjacent to the generator. No measurable response was observed at the bearing located between LPA and LPB. This corroborates the fact that the subject mode is a generator twist mode, outlined conceptually in Figure 7. (The manufacturer predicted a 2 nd generator twist mode at Hz.) Torsional displacement or modeshape Node (point of zero torsional displacement) Conceptual depiction of the generator 1 st twisting mode Conceptual depiction of the generator 2 nd twisting mode J. Ferleger May 2014 Figure 7: Outline of generator 1 st and 2 nd twist modes Compared to the first three fundamental system modes identified in the table in Figure 5, the stress level associated with the generator second twist mode appears low. This can be clearly detected in Figure 8. (This observation is particularly significant given the fact that the strain gauges at T6 and T8 bearings were strategically placed to detect the 2 nd twist mode of the generator.) The L-0 out-of-phase and in-phase bucket modes were detected at Hz and Hz, respectively, at 10 MW load test point, summarized in Figure 8 below. The predicted frequencies of these modes at full load are given in the table in Figure 5 (as described in the following section, the torsional frequencies at 10 MW and at full load conditions are slightly different.) Generator 2 nd twist mode Figure 8: Torsional frequency spectrum as measured during the test at 10 MW load [6] 9

10 The 2 nd generator twist mode merges with the with the 2/rev electrical spike, identified in Figure 9, at all test points at loads higher than 10 MW as shown. (The frequency of 1 st generator twist mode, depicted in Figure 7, was not provided by the OEM.) Approximate amplitude of the generator second twist mode Figure 9: Partial summary of the torsional test [6] DISCUSSION OF THE TORSIONAL TEST RESULTS The OEM conducted a monitoring test, which is performed while the unit is on line. Therefore, it cannot be completely ruled out that some non-torsional modes were detected by the test instruments. However, the test results match the predicted frequencies closely. Thus, it can be concluded with a high degree of probability that the unit features a 2 nd generator twist mode in the close vicinity of 120 Hz. The frequency of this mode increases slightly between the full-speed-no-load test point and the 10 MW test point, as demonstrated in Figure 9, probably due to increase in stiffness of the generator rotor, which increases with increase in electrical torque. The same frequency drops somewhat at the higher load points because, as the load increases, so does the average temperature of the rotor. This results in a small drop in the Young s and Shear moduli and hence in a small frequency drop (Based on material properties given in ASME B31.1, Table C-1 [11] and the fact that the torsional frequency is a function of square root of Shear Modulus, a moderate temperature increase of approximately 50 ºF would cause a 0.5% frequency increase.) With the temperature effect included, the generator 2 nd twist mode 10

11 is practically indistinguishable from the 2 rev (120 Hz) peak. This would not be considered acceptable on a new unit, unless it can be unequivocally shown that the resultant response will not cause fatigue cracks within the life of the unit. An analysis of whether the stress at the critical location in the subject mode is sufficient to cause fatigue failure can be performed [11]. Given the measured strain, it is possible to determine the actual vibratory stress at the highest stress point for this mode. Imposing the result on a Goodman diagram at an assumed or measured value for the negative sequence current should yield the accumulated fatigue damage, as depicted schematically in Figure 10. In addition, a product line evaluation, if performed by the OEM, can provide insight into the performance of other similar units. ) n tio itia In k c ra C =.0 (1 e g a s U e u tig a F Fatigue damage Fault Duration NSC= 10.0 NSC= 20.0 NSC= 30.0 NSC= 40.0 NSC= 50.0 NSC= 60.0 NSC= 70.0 NSC= 80.0 NSC= 90.0 NSC= Fault Duration (sec) Figure 10: Fatigue life usage as a function of time and negative sequence current (courtesy of MPR) MITIGATING FACTORS As stated before, in spite of the fact that the 2 nd generator twist mode coincides with the double line excitation of 120 Hz, the affected unit has not demonstrated any distress associated with torsional response. The explanation for this can be divided into two categories: Absence of significant torsional stimulus/negative sequence current at the affected unit: As can be deduced from Figure 10, fatigue damage will not occur unless a significant level of negative sequence current, acting on the generator rotor for a measurable length of time, is present. Absence of serious grid disturbances, i.e. absence of any significant torsional excitations, was given by the manufacturer as the main explanation for the absence of high cycle fatigue cracks, which can be attributed to the torsional excitations, during the life of the unit. Torque cancellation effect: Detailed mode shape of the generator 2 nd twist mode was not provided by the manufacturer. Thus the location of the node, present in the middle of the generator, and the degree of torque cancellation in the particular mode, is not known. However, it is reasonable to assume that a fair amount of torque cancellation, illustrated in Figures 11 and 12, is present in the generator 2 nd twisting mode. Therefore, energy input into the remainder of the power train is significantly reduced. The torque cancellation effect is likely to contribute to the fact that the amplitude of this mode, measured during the torsional test, was small compared to the amplitudes of the primary system modes. 11

12 Complete torque cancellation Modeshape Figure 11: Mode with complete energy cancellation (zero net resultant torque) Torque cancellation Modeshape Resultant torque SUMMARY Figure 12: Mode with partial energy cancellation (non-zero net resultant torque) J. Ferleger May 2014 Presence of a torsional mode coincident with the double line excitation of 120 Hz has been predicted by calculations and essentially confirmed with a torsional test on the operating unit. However, consistent absence of any distress that can be attributed to such resonance in over twenty years of operation suggests that the response in this mode may be insufficient to initiate high cycle fatigue cracking of the rotating components. The absence of high cycle fatigue cracks can be attributed to energy cancellation effects which tend to suppress such mode and/or low level grid electrical excitations at this unit. Nevertheless, as recommended by the manufacturer for this unit, a coincidence between the 120 Hz electrical excitation and any generator twist mode should be avoided at any operating plant. Adhering to guidelines outlined in ISO is highly recommended. ` REFERENCES 1. ISO 7919 Evaluation of Machine Vibration by Measurements on Rotating Shafts 2. ISO Evaluation of Machine Vibration by Measurements on Non-rotating Parts 3. ISO Torsional Vibration of Rotating Machinery 4. NEIL Nuclear Electric Insurance Limited Loss of Control Standards 5. EPRI - TG Torsional Vibration Interaction with the Electrical Network 6. OEM Torsional Test Report (Proprietary) 7. J. A. LaRosa, G. C. Kung, D. D. Rosard, Analysis of Turbine Blade Vibrations Induced by Electrical-Mechanical Interactions, ASME Conference, Alstom Torsional Vibration Presentation, EPRI D. Evans, H. Giesecke, Resolution of Torsional Vibration Issue for Large TG 10. Non Destructive Examination Report (Proprietary) 11. ASME Code for Pressure Piping, B H. Giesecke, Measuring Torsional Natural Frequencies of TG by on-line Monitoring 12

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY

CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY 135 CHAPTER 6 MECHANICAL SHOCK TESTS ON DIP-PCB ASSEMBLY 6.1 INTRODUCTION Shock is often defined as a rapid transfer of energy to a mechanical system, which results in a significant increase in the stress,

More information

Thermal Hydraulics Design Limits Class Note II. Professor Neil E. Todreas

Thermal Hydraulics Design Limits Class Note II. Professor Neil E. Todreas Thermal Hydraulics Design Limits Class Note II Professor Neil E. Todreas The following discussion of steady state and transient design limits is extracted from the theses of Carter Shuffler and Jarrod

More information

MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION

MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION Technical Paper MAIN SHAFT SUPPORT FOR WIND TURBINE WITH A FIXED AND FLOATING BEARING CONFIGURATION Tapered Double Inner Row Bearing Vs. Spherical Roller Bearing On The Fixed Position Laurentiu Ionescu,

More information

Generators for the age of variable power generation

Generators for the age of variable power generation 6 ABB REVIEW SERVICE AND RELIABILITY SERVICE AND RELIABILITY Generators for the age of variable power generation Grid-support plants are subject to frequent starts and stops, and rapid load cycling. Improving

More information

MECHANICAL EQUIPMENT. Engineering. Theory & Practice. Vibration & Rubber Engineering Solutions

MECHANICAL EQUIPMENT. Engineering. Theory & Practice. Vibration & Rubber Engineering Solutions MECHANICAL EQUIPMENT Engineering Theory & Practice Vibration & Rubber Engineering Solutions The characteristic of an anti-vibration mounting that mainly determines its efficiency as a device for storing

More information

2. Write the expression for estimation of the natural frequency of free torsional vibration of a shaft. (N/D 15)

2. Write the expression for estimation of the natural frequency of free torsional vibration of a shaft. (N/D 15) ME 6505 DYNAMICS OF MACHINES Fifth Semester Mechanical Engineering (Regulations 2013) Unit III PART A 1. Write the mathematical expression for a free vibration system with viscous damping. (N/D 15) Viscous

More information

NEIL Turbine Generator Risk Assessment. Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013

NEIL Turbine Generator Risk Assessment. Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013 NEIL Turbine Generator Risk Assessment Todd Raymond Loss Risk Analysis Manager Nuclear Service Organization April 16-17, 2013 Program Origin Large Losses due to Turbine Generator Failures in recent years

More information

IDENTIFICATION OF ABNORMAL ROTOR DYNAMIC STIFFNESS USING MEASURED VIBRATION INFORMATION AND ANALYTICAL MODELING

IDENTIFICATION OF ABNORMAL ROTOR DYNAMIC STIFFNESS USING MEASURED VIBRATION INFORMATION AND ANALYTICAL MODELING Proceedings of PWR2009 ASME Power July 21-23, 2009, Albuquerque, New Mexico, USA Power2009-81019 IDENTIFICATION OF ABNORMAL ROTOR DYNAMIC STIFFNESS USING MEASURED VIBRATION INFORMATION AND ANALYTICAL MODELING

More information

CHAPTER 1 BALANCING BALANCING OF ROTATING MASSES

CHAPTER 1 BALANCING BALANCING OF ROTATING MASSES CHAPTER 1 BALANCING Dynamics of Machinery ( 2161901) 1. Attempt the following questions. I. Need of balancing II. Primary unbalanced force in reciprocating engine. III. Explain clearly the terms static

More information

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR Velimir Nedic Thomas A. Lipo Wisconsin Power Electronic Research Center University of Wisconsin Madison

More information

OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT

OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT OBSERVATIONS ABOUT ROTATING AND RECIPROCATING EQUIPMENT Brian Howes Beta Machinery Analysis, Calgary, AB, Canada, T3C 0J7 ABSTRACT This paper discusses several small issues that have occurred in the last

More information

Active Control of Sheet Motion for a Hot-Dip Galvanizing Line. Dr. Stuart J. Shelley Dr. Thomas D. Sharp Mr. Ronald C. Merkel

Active Control of Sheet Motion for a Hot-Dip Galvanizing Line. Dr. Stuart J. Shelley Dr. Thomas D. Sharp Mr. Ronald C. Merkel Active Control of Sheet Motion for a Hot-Dip Galvanizing Line Dr. Stuart J. Shelley Dr. Thomas D. Sharp Mr. Ronald C. Merkel Sheet Dynamics, Ltd. 1776 Mentor Avenue, Suite 17 Cincinnati, Ohio 45242 Active

More information

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor > 57 < 1 Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor Masaki Yagami, Non Member, IEEE, Junji Tamura, Senior Member, IEEE Abstract This paper

More information

Module 2 : Dynamics of Rotating Bodies; Unbalance Effects and Balancing of Inertia Forces

Module 2 : Dynamics of Rotating Bodies; Unbalance Effects and Balancing of Inertia Forces Module 2 : Dynamics of Rotating Bodies; Unbalance Effects and Balancing of Inertia Forces Lecture 3 : Concept of unbalance; effect of unbalance Objectives In this lecture you will learn the following Unbalance

More information

Analysis of Eclipse Drive Train for Wind Turbine Transmission System

Analysis of Eclipse Drive Train for Wind Turbine Transmission System ISSN 2395-1621 Analysis of Eclipse Drive Train for Wind Turbine Transmission System #1 P.A. Katre, #2 S.G. Ganiger 1 pankaj12345katre@gmail.com 2 somu.ganiger@gmail.com #1 Department of Mechanical Engineering,

More information

VALMONT MITIGATOR TR1

VALMONT MITIGATOR TR1 VALMONT MITIGATOR TR1 Research Verification of the Valmont TR1 Damper Performance MITIGATOR TR1 VIBRATION DAMPER The Valmont TR1 damper has been specifically designed using vibration theory and innovative

More information

BY: Paul Behnke ITT Industries, Industrial Process. Juan Gamarra Mechanical Solutions, Inc.

BY: Paul Behnke ITT Industries, Industrial Process. Juan Gamarra Mechanical Solutions, Inc. DRIVE SHAFT FAILURE ANALYSIS ON A MULTISTAGE VERTICAL TURBINE PUMP IN RIVER WATER SUPPLY SERVICE IN A NICKEL AND COBALT MINE IN I MADAGASCAR -BASED ON ODS AND FEA Juan Gamarra Mechanical Solutions, Inc.

More information

TRANSLATION (OR LINEAR)

TRANSLATION (OR LINEAR) 5) Load Bearing Mechanisms Load bearing mechanisms are the structural backbone of any linear / rotary motion system, and are a critical consideration. This section will introduce most of the more common

More information

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE Michael W. Smiarowski, Rainer Leo, Christof Scholten, Siemens Power Generation (PG), Germany John Blake,

More information

Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure

Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure Journal of Engineering and Technology of the Open University of Sri Lanka (JET-OUSL), Vol. 4, No.1, 2016 Fault Diagnosis of Lakvijaya Power Plant: A Case Study of an Anti-Rotational Pin Failure N.C Tantrigoda

More information

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 61 CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 3.1 INTRODUCTION The modeling of the real time system with STATCOM using MiPower simulation software is presented in this

More information

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 08, 2015 ISSN (online): 2321-0613 Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4

More information

White Paper. Stator Coupling Model Analysis By Johan Ihsan Mahmood Motion Control Products Division, Avago Technologies. Abstract. 1.

White Paper. Stator Coupling Model Analysis By Johan Ihsan Mahmood Motion Control Products Division, Avago Technologies. Abstract. 1. Stator Coupling Model Analysis By Johan Ihsan Mahmood Motion Control Products Division, Avago Technologies White Paper Abstract In this study, finite element analysis was used to optimize the design of

More information

IDENTIFYING DISC COUPLING FAILURES COUPLING FUNDAMENTALS

IDENTIFYING DISC COUPLING FAILURES COUPLING FUNDAMENTALS IDENTIFYING DISC COUPLING FAILURES While couplings are designed for infinite life, they must be operated within their intended design limits in order to achieve optimal performance. Due to installation

More information

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION F2004F461 AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION 1 Badiola, Virginia*, 2 Pintor, Jesús María, 3 Gainza, Gorka 1 Dana Equipamientos S.A., España, 2 Universidad Pública de Navarra,

More information

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011 Numerical modal analysis of Howell Bunger valve using FEM method Farid Vakili Tahami, Mohammad Zehsaz, Mohammad Ali Saeimi Sadigh, Amin Paykani Department of Mechanical Engineering, University of Tabriz,

More information

AGN Unbalanced Loads

AGN Unbalanced Loads Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 017 - Unbalanced Loads There will inevitably be some applications where a Generating Set is supplying power to

More information

GatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA

GatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA SELECTING SYNCHRONOUS BELTS FOR PRECISE POSITIONING A W Wallin Power Transmission Design February, 1989 Synchronous belts are well known for precise positioning. However, some precision applications require

More information

PRECISION BELLOWS COUPLINGS

PRECISION BELLOWS COUPLINGS PRECISION BELLOWS COUPLINGS Bellows couplings are used where precise rotation, high speeds, and dynamic motion must be transmitted. They exhibit zero backlash and a high level of torsional stiffness, offering

More information

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS CLASSIFICATION OF ROLLING-ELEMENT BEARINGS Ball bearings can operate at higher speed in comparison to roller bearings because they have lower friction. In particular, the balls have less viscous resistance

More information

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood Prepared for: SCE&G Fossil/Hydro June 30, 2008 Prepared by: SCE&G Transmission Planning Table of Contents

More information

RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM

RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM RELIABILITY IMPROVEMENT OF ACCESSORY GEARBOX BEVEL DRIVES Kozharinov Egor* *CIAM egor@ciam.ru Keywords: Bevel gears, accessory drives, resonance oscillations, Coulomb friction damping Abstract Bevel gear

More information

R10 Set No: 1 ''' ' '' '' '' Code No: R31033

R10 Set No: 1 ''' ' '' '' '' Code No: R31033 R10 Set No: 1 III B.Tech. I Semester Regular and Supplementary Examinations, December - 2013 DYNAMICS OF MACHINERY (Common to Mechanical Engineering and Automobile Engineering) Time: 3 Hours Max Marks:

More information

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G] ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G] Topics INTRODUCTION - Mechanical vibrations in electrified trains

More information

Research on the Structure of Linear Oscillation Motor and the Corresponding Applications on Piston Type Refrigeration Compressor

Research on the Structure of Linear Oscillation Motor and the Corresponding Applications on Piston Type Refrigeration Compressor International Conference on Informatization in Education, Management and Business (IEMB 2015) Research on the Structure of Linear Oscillation Motor and the Corresponding Applications on Piston Type Refrigeration

More information

DEVELOPMENT AND IMPLEMENTATION OF VFD ACTIVE DAMPING TO SMOOTH TORSIONAL VIBRATIONS ON A GEARED TRAIN

DEVELOPMENT AND IMPLEMENTATION OF VFD ACTIVE DAMPING TO SMOOTH TORSIONAL VIBRATIONS ON A GEARED TRAIN DEVELOPMENT AND IMPLEMENTATION OF VFD ACTIVE DAMPING TO SMOOTH TORSIONAL VIBRATIONS ON A GEARED TRAIN L. Naldi GE Oil&Gas P. Rotondo GE Oil&Gas J. Kocur ExxonMobil 37 th Turbomachinery Symposium Talk Overview

More information

2 Technical Background

2 Technical Background 2 Technical Background Vibration In order to understand some of the most difficult R- 2800 development issues, we must first briefly digress for a quick vibration tutorial. The literature concerning engine

More information

Unit Protection System for Pumped-Storage Power Stations

Unit Protection System for Pumped-Storage Power Stations Unit Protection System for Pumped-Storage Power Stations 1. Introduction In many power systems, pumped-storage power stations are used in addition to run-of-river power stations. These power stations serve

More information

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis

Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis Dynamic characteristics of railway concrete sleepers using impact excitation techniques and model analysis Akira Aikawa *, Fumihiro Urakawa *, Kazuhisa Abe **, Akira Namura * * Railway Technical Research

More information

Examples of Electric Drive Solutions and Applied Technologies

Examples of Electric Drive Solutions and Applied Technologies Examples of Electric Drive Solutions and Applied Technologies 2 Examples of Electric Drive Solutions and Applied Technologies Atsushi Sugiura Haruo Nemoto Ken Hirata OVERVIEW: Hitachi has worked on specific

More information

A Practical Guide to Free Energy Devices

A Practical Guide to Free Energy Devices A Practical Guide to Free Energy Devices Part PatD20: Last updated: 26th September 2006 Author: Patrick J. Kelly This patent covers a device which is claimed to have a greater output power than the input

More information

White paper: Originally published in ISA InTech Magazine Page 1

White paper: Originally published in ISA InTech Magazine Page 1 Page 1 Improving Differential Pressure Diaphragm Seal System Performance and Installed Cost Tuned-Systems ; Deliver the Best Practice Diaphragm Seal Installation To Compensate Errors Caused by Temperature

More information

Evaluating and Correcting Subsynchronous Vibration in Vertical Pumps

Evaluating and Correcting Subsynchronous Vibration in Vertical Pumps Dyrobes Rotordynamics Software https://dyrobes.com Evaluating and Correcting Subsynchronous Vibration in Vertical Pumps Abstract By Malcolm E. Leader, P.E. Applied Machinery Dynamics Co. Kelly J. Conner

More information

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS Objective Describe the necessary conditions for motor and generator operation. Calculate the force on a conductor carrying current in the presence of the

More information

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s.

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s. A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s. Abstract: The paper presents a solution of a pipeline constrained oscillation

More information

CHAPTER 1. Introduction and Literature Review

CHAPTER 1. Introduction and Literature Review CHAPTER 1 Introduction and Literature Review 1.1 Introduction The Active Magnetic Bearing (AMB) is a device that uses electromagnetic forces to support a rotor without mechanical contact. The AMB offers

More information

Economic Impact of Derated Climb on Large Commercial Engines

Economic Impact of Derated Climb on Large Commercial Engines Economic Impact of Derated Climb on Large Commercial Engines Article 8 Rick Donaldson, Dan Fischer, John Gough, Mike Rysz GE This article is presented as part of the 2007 Boeing Performance and Flight

More information

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY

TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY U.P.B. Sci. Bull., Series D, Vol. 77, Iss. 3, 2015 ISSN 1454-2358 TURBOGENERATOR DYNAMIC ANALYSIS TO IDENTIFY CRITICAL SPEED AND VIBRATION SEVERITY Claudiu BISU 1, Florian ISTRATE 2, Marin ANICA 3 Vibration

More information

An Investigation into a new method to repair motor cores and improve Efficiency

An Investigation into a new method to repair motor cores and improve Efficiency An Investigation into a new method to repair motor cores and improve Efficiency Henk de Swart Marthinusen & Coutts Dennis Willemse, Gerhard Bergh, Thava Perumal Sasol Introduction A South African based

More information

TYPE TSC/TLC T SERIES FLEXIBLE DISC COUPLINGS

TYPE TSC/TLC T SERIES FLEXIBLE DISC COUPLINGS TYPE TSC/TLC A Stainless steel flexible discs B Overload collars C Cartridge transmission unit D Anti-fly feature E Anti-corrosion treatment F Hubs with API puller holes G Robust hub bolt H Large shaft

More information

Throwback Thursday :: Bently Nevada Dual Probe Versus Shaft Rider

Throwback Thursday :: Bently Nevada Dual Probe Versus Shaft Rider Throwback Thursday :: Bently Nevada Dual Probe Versus Shaft Rider Date : February 12, 2015 Bently Nevada has a rich history of machinery condition monitoring experience and has always placed a high priority

More information

DAMPING OF VIBRATION IN BELT-DRIVEN MOTION SYSTEMS USING A LAYER OF LOW-DENSITY FOAM

DAMPING OF VIBRATION IN BELT-DRIVEN MOTION SYSTEMS USING A LAYER OF LOW-DENSITY FOAM DAMPING OF VIBRATION IN BELT-DRIVEN MOTION SYSTEMS USING A LAYER OF LOW-DENSITY FOAM Kripa K. Varanasi and Samir A. Nayfeh Department of Mechanical Engineering Massachusetts Institute of Technology Cambridge,

More information

w o r k o G E x - p e S i n c e r t Elegance and Strength BBR HiAm CONA Strand Stay Cable Damping Systems

w o r k o G E x - p e S i n c e r t Elegance and Strength BBR HiAm CONA Strand Stay Cable Damping Systems o b a l N e t w o r k l o G f A E x - p e S i n c e 1 9 4 4 - s r t Elegance and Strength BBR HiAm CONA Strand Stay Cable Damping Systems 1 Cable vibration and damping Despite the wide use of cable-stayed

More information

ISCORMA-3, Cleveland, Ohio, September 2005

ISCORMA-3, Cleveland, Ohio, September 2005 Dyrobes Rotordynamics Software https://dyrobes.com ISCORMA-3, Cleveland, Ohio, 19-23 September 2005 APPLICATION OF ROTOR DYNAMIC ANALYSIS FOR EVALUATION OF SYNCHRONOUS SPEED INSTABILITY AND AMPLITUDE HYSTERESIS

More information

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers U. Bin-Nun FLIR Systems Inc. Boston, MA 01862 ABSTRACT Cryocooler self induced vibration is a major consideration in the design of IR

More information

THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS = r 345 E 47 St., New York, N.Y credit should be given to ASIVIE to cs P i n and the autnor(sl

THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS = r 345 E 47 St., New York, N.Y credit should be given to ASIVIE to cs P i n and the autnor(sl 80-GT-151 u `^, `rery.,,,,teg 3 THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS = r 345 E 47 St., New York, N.Y. 10017 `.. ' The Society shall not be responsible for,t.item nts or opinions advanced in papers

More information

IMPACT OF WIRELESS LASER BASED SHAFT ALIGNMENT ON VIBRATION AND STG COUPLING FAILURE. Ned M. Endres, Senior MDS Specialist

IMPACT OF WIRELESS LASER BASED SHAFT ALIGNMENT ON VIBRATION AND STG COUPLING FAILURE. Ned M. Endres, Senior MDS Specialist Proceedings of PWR2007 ASME Power July 17-19, 2007, San Antonio, Texas, USA Power2007-22038 IMPACT OF WIRELESS LASER BASED SHAFT ALIGNMENT ON VIBRATION AND STG COUPLING FAILURE Ned M. Endres, Senior MDS

More information

Analysis and control of vehicle steering wheel angular vibrations

Analysis and control of vehicle steering wheel angular vibrations Analysis and control of vehicle steering wheel angular vibrations T. LANDREAU - V. GILLET Auto Chassis International Chassis Engineering Department Summary : The steering wheel vibration is analyzed through

More information

Minimizing Noise. Marybeth G. Nored Dr. Klaus Brun Eugene Buddy Broerman Augusto Garcia Hernandez Dennis Tweten. Southwest Research Institute

Minimizing Noise. Marybeth G. Nored Dr. Klaus Brun Eugene Buddy Broerman Augusto Garcia Hernandez Dennis Tweten. Southwest Research Institute Minimizing Noise Marybeth G. Nored Dr. Klaus Brun Eugene Buddy Broerman Augusto Garcia Hernandez Dennis Tweten Southwest Research Institute Gas Electric Partnership Workshop September 9, 2010 Photo courtesy

More information

Balancing with the presence of a rub

Balancing with the presence of a rub Balancing with the presence of a rub Nicolas Péton 1 1 GE Measurement & Control, 14 rue de la Haltinière, CS 10356, 44303 Nantes, Cedex 3, France Abstract During commissioning of a cogeneration plant the

More information

White Paper. Phone: Fax: Advance Lifts, Inc. All rights reserved.

White Paper. Phone: Fax: Advance Lifts, Inc. All rights reserved. White Paper TURNTABLE AppLicATioN GUidE This section covers the full range of turntables manufactured by Advance Lifts. The basic information necessary to select an appropriate turntable for an application

More information

ENHANCED ROTORDYNAMICS FOR HIGH POWER CRYOGENIC TURBINE GENERATORS

ENHANCED ROTORDYNAMICS FOR HIGH POWER CRYOGENIC TURBINE GENERATORS The 9th International Symposium on Transport Phenomena and Dynamics of Rotating Machinery Honolulu, Hawaii, February -1, ENHANCED ROTORDYNAMICS FOR HIGH POWER CRYOGENIC TURBINE GENERATORS Joel V. Madison

More information

Vibration Diagnostics and Condition Assessment As Economic Tool

Vibration Diagnostics and Condition Assessment As Economic Tool IFToMM 7th International Conference on Rotor Dynamics, Vienna, Austria, September 25-28, 2006 Vibration Diagnostics and Condition Assessment As Economic Tool Zlatan Racic D.B.A. Z-R Consulting 5698 South

More information

Fundamental Specifications for Eliminating Resonance on Reciprocating Machinery

Fundamental Specifications for Eliminating Resonance on Reciprocating Machinery 1 Fundamental Specifications for Eliminating Resonance on Reciprocating Machinery Frank Fifer, P.Eng. Beta Machinery Analysis Ltd. Houston, Texas Introduction Question: What is the purpose of performing

More information

TRANSMISSION PLANNING CRITERIA

TRANSMISSION PLANNING CRITERIA CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003-3502 Effective Date: TRANSMISSION PLANNING CRITERIA PURPOSE This specification describes Con Edison s Criteria for assessing

More information

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE

A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE A CASE STUDY OF A FLOW-INDUCED TORSIONAL RESONANCE William F. Eckert, P.Eng., Ph.D. Field Services Manager Brian C. Howes, M.Sc., P.Eng. Chief Engineer Beta Machinery Analysis Ltd., Calgary, AB, Canada,

More information

AGN 041 Alternator Operating Speed

AGN 041 Alternator Operating Speed Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 041 Alternator Operating Speed INTRODUCTION AvK and STAMFORD synchronous a.c. generators (alternators) are designed

More information

III B.Tech I Semester Supplementary Examinations, May/June

III B.Tech I Semester Supplementary Examinations, May/June Set No. 1 III B.Tech I Semester Supplementary Examinations, May/June - 2015 1 a) Derive the expression for Gyroscopic Couple? b) A disc with radius of gyration of 60mm and a mass of 4kg is mounted centrally

More information

Clay McClinton Rotating Equipment Reliability Analyst, Chevron. Dan Phillips Manager Global Field Services, Kop-Flex

Clay McClinton Rotating Equipment Reliability Analyst, Chevron. Dan Phillips Manager Global Field Services, Kop-Flex COUPLING FAILURE DUE TO A MOTOR FAULT COUPLING FAILURE DUE TO A MOTOR FAULT Clay McClinton Rotating Equipment Reliability Analyst, Chevron Dan Phillips Manager Global Field Services, Kop-Flex Joe Corcoran

More information

ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING

ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING ON THE DETERMINATION OF BEARING SUPPORT PEDESTAL STIFFNESS USING SHAKER TESTING R. Subbiah Siemens Energy, Inc., 4400 Alafaya trail, Orlando FL 32817 USA Abstract An approach that enables rotor dynamists

More information

Simulating Rotary Draw Bending and Tube Hydroforming

Simulating Rotary Draw Bending and Tube Hydroforming Abstract: Simulating Rotary Draw Bending and Tube Hydroforming Dilip K Mahanty, Narendran M. Balan Engineering Services Group, Tata Consultancy Services Tube hydroforming is currently an active area of

More information

PROFILING OF PULSATION AND VIBRATION IN COMPLEX RECIPROCATING COMPRESSOR FACILITIES

PROFILING OF PULSATION AND VIBRATION IN COMPLEX RECIPROCATING COMPRESSOR FACILITIES PROFILING OF PULSATION AND VIBRATION IN COMPLEX RECIPROCATING COMPRESSOR FACILITIES Bryan Fofonoff, P.Eng. Beta Machinery Analysis Ltd., 300, 1615 10 th Ave. SW., Calgary, AB, Canada, T3C 0J7 ABSTRACT

More information

Static And Modal Analysis of Tractor Power Take Off (PTO) Gearbox Housing

Static And Modal Analysis of Tractor Power Take Off (PTO) Gearbox Housing Static And Modal Analysis of Tractor Power Take Off (PTO) Gearbox Housing Gopali S Lamani 1, Prof: S.R.Basavaraddi 2, Assistant Professor, Department of Mechanical Engineering, JSPM NTC RSSOER,India1 Professor,

More information

ROTATING MACHINERY DYNAMICS

ROTATING MACHINERY DYNAMICS Pepperdam Industrial Park Phone 800-343-0803 7261 Investment Drive Fax 843-552-4790 N. Charleston, SC 29418 www.wheeler-ind.com ROTATING MACHINERY DYNAMICS SOFTWARE MODULE LIST Fluid Film Bearings Featuring

More information

Root Cause Analysis of a vibration problem in a propylene turbo compressor. Pieter van Beek, Jan Smeulers

Root Cause Analysis of a vibration problem in a propylene turbo compressor. Pieter van Beek, Jan Smeulers Root Cause Analysis of a vibration problem in a propylene turbo compressor Pieter van Beek, Jan Smeulers Problem description A newly installed turbo compressor system for propylene showed vibrations in

More information

AGN Single Phase Loading for Re- Connectable 3-Phase Windings

AGN Single Phase Loading for Re- Connectable 3-Phase Windings Application Guidance Notes: Technical Information from Cummins Alternator Technologies AGN 154 - Single Phase Loading for Re- Connectable 3-Phase Windings TECHNICAL OVERVIEW It must be accepted; when reconnecting

More information

Clutch Damper High Cycle Fatigue

Clutch Damper High Cycle Fatigue Abstract Clutch Damper High Cycle Fatigue KD Wang LUK Incorporated Kalyan Bairavarasu LUK Incorporated The clutch damper of the manual transmission system is prone to vibration related fatigue damage when

More information

I. Tire Heat Generation and Transfer:

I. Tire Heat Generation and Transfer: Caleb Holloway - Owner calebh@izzeracing.com +1 (443) 765 7685 I. Tire Heat Generation and Transfer: It is important to first understand how heat is generated within a tire and how that heat is transferred

More information

Fig.1 Sky-hook damper

Fig.1 Sky-hook damper 1. Introduction To improve the ride comfort of the Maglev train, control techniques are important. Three control techniques were introduced into the Yamanashi Maglev Test Line vehicle. One method uses

More information

Failure of a Test Rig Operating with Pressurized Gas Bearings: a Lesson on Humility

Failure of a Test Rig Operating with Pressurized Gas Bearings: a Lesson on Humility Proceedings of ASME Turbo Expo 2015: Turbine Technical Conference and Exposition, June 15-19, 2015, Montreal, Canada GT2015-42556 Failure of a Test Rig Operating with Pressurized Gas Bearings: a Lesson

More information

Rotor imbalance cancellation

Rotor imbalance cancellation White paper Rotor imbalance cancellation Imbalance in a wind turbine rotor is a typical problem of both new and older wind turbines. This paper describes an approach for minimizing rotor imbalance using

More information

BELT-DRIVEN ALTERNATORS

BELT-DRIVEN ALTERNATORS CHAPTER 13 BELT-DRIVEN ALTERNATORS INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy using the principle of magnetic induction. This principle is based on the

More information

Sheet 1 Variable loading

Sheet 1 Variable loading Sheet 1 Variable loading 1. Estimate S e for the following materials: a. AISI 1020 CD steel. b. AISI 1080 HR steel. c. 2024 T3 aluminum. d. AISI 4340 steel heat-treated to a tensile strength of 1700 MPa.

More information

DYNAMIC ABSORBERS FOR SOLVING RESONANCE PROBLEMS

DYNAMIC ABSORBERS FOR SOLVING RESONANCE PROBLEMS DYNAMIC ABSORBERS FOR SOLVING RESONANCE PROBLEMS Randy Fox Senior Staff Instructor Entek IRD International Corp. Houston, TX ABSTRACT Many experts in vibration analysis will agree that resonance is one

More information

B.TECH III Year I Semester (R09) Regular & Supplementary Examinations November 2012 DYNAMICS OF MACHINERY

B.TECH III Year I Semester (R09) Regular & Supplementary Examinations November 2012 DYNAMICS OF MACHINERY 1 B.TECH III Year I Semester (R09) Regular & Supplementary Examinations November 2012 DYNAMICS OF MACHINERY (Mechanical Engineering) Time: 3 hours Max. Marks: 70 Answer any FIVE questions All questions

More information

Procedia Engineering 00 (2009) Mountain bike wheel endurance testing and modeling. Robin C. Redfield a,*, Cory Sutela b

Procedia Engineering 00 (2009) Mountain bike wheel endurance testing and modeling. Robin C. Redfield a,*, Cory Sutela b Procedia Engineering (29) Procedia Engineering www.elsevier.com/locate/procedia 9 th Conference of the International Sports Engineering Association (ISEA) Mountain bike wheel endurance testing and modeling

More information

High Speed, Low Weight Momentum/reaction Wheels. Larry Wilhide, Valley Forge Composite Tech, Inc. P.O. Box 344 Carlisle, PA (717)

High Speed, Low Weight Momentum/reaction Wheels. Larry Wilhide, Valley Forge Composite Tech, Inc. P.O. Box 344 Carlisle, PA (717) SSC99-XI-1 High Speed, Low Weight Momentum/reaction Wheels, Valley Forge Composite Tech, Inc. P.O. Box 344 Carlisle, PA 17013 (717) 776-3249 Louis Brothers, Valley Forge Composite Tech, Inc. P.O. Box 344

More information

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código Letra de código Código de rotor bloqueado Rotor bloqueado, Letra de código kva / hp kva / hp A 0.00 3.15 L 9.00 10.00 B 3.15 3.55 M 10.00 11.00 C 3.55 4.00 N 11.00 12.50 D 4.00 4.50 P 12.50 14.00 E 4.50

More information

Plate Girder and Stiffener

Plate Girder and Stiffener Plate Girder and Stiffener (Gelagar Pelat dan Pengaku) Dr. AZ Department of Civil Engineering Brawijaya University Introduction These girders are usually fabricated from welded plates and thus are called

More information

Balancing and over-speed testing of flexible rotors

Balancing and over-speed testing of flexible rotors Balancing and over-speed testing of flexible rotors Installations for low- and high-speed balancing and for over-speed testing HS 16 - HS 34 Application Balancing of flexible rotors from turbo-machinery

More information

INSTRUCTIONS FOR TRI-METRIC BATTERY MONITOR May 8, 1996

INSTRUCTIONS FOR TRI-METRIC BATTERY MONITOR May 8, 1996 INSTRUCTIONS FOR TRI-METRIC BATTERY MONITOR May 8, 1996 PART 2: SUPPLEMENTARY INSTRUCTIONS FOR SEVEN TriMetric DATA MONITORING FUNCTIONS. A: Introduction B: Summary Description of the seven data monitoring

More information

ANTI-BACKLASH GEAR TRAIN INVESTIGATION. Zengxin Gao, Jani Tähtinen

ANTI-BACKLASH GEAR TRAIN INVESTIGATION. Zengxin Gao, Jani Tähtinen Zengxin Gao, Jani Tähtinen Wärtsilä Finland Oy Järvikatu 2-4, P.O. Box 244 FI-65101 Vaasa zengxin.gao@wartsila.com jani.tahtinen@wartsila.com 1 INTRODUCTION This paper is a continuation of study on Wärtsilä

More information

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE Yunqi WANG, B.T. PHUNG, Jayashri RAVISHANKAR School of Electrical Engineering and Telecommunications The

More information

Transmission Error in Screw Compressor Rotors

Transmission Error in Screw Compressor Rotors Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Transmission Error in Screw Compressor Rotors Jack Sauls Trane Follow this and additional

More information

Doubly fed electric machine

Doubly fed electric machine Doubly fed electric machine Doubly fed electric machines are electric motors or electric generators that have windings on both stationary and rotating parts, where both windings transfer significant power

More information

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd.

High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd. Hitachi Review Vol. 53 (2004), No. 3 121 High-voltage Direct Inverter Applied to Induced Draft Fan Motor at Takehara Thermal Power Station No. 3 of Electric Power Development Co., Ltd. Hiroaki Yamada Kiyoshi

More information

Large Air Cooled Generator Failure

Large Air Cooled Generator Failure Large Air Cooled Generator Failure Henry Tarnecky AVP - Sr. Engineering Specialist, FM Global 2017 IRIS Rotating Machinery Conference FM Global Basics Commercial/Industrial Property Insurer Mutual Co.,

More information

Study on Mechanism of Impact Noise on Steering Gear While Turning Steering Wheel in Opposite Directions

Study on Mechanism of Impact Noise on Steering Gear While Turning Steering Wheel in Opposite Directions Study on Mechanism of Impact Noise on Steering Gear While Turning Steering Wheel in Opposite Directions Jeong-Tae Kim 1 ; Jong Wha Lee 2 ; Sun Mok Lee 3 ; Taewhwi Lee 4 ; Woong-Gi Kim 5 1 Hyundai Mobis,

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 14691 First edition 1999-11-01 Petroleum and natural gas industries Flexible couplings for mechanical power transmission General purpose applications Industries du pétrole et

More information

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,

More information