1 Flow PanaFlow LZ User s Manual bhge.com Rev. A September 2017

2

3 Preface Product Registration Thank you for purchasing your PanaFlow LZ from Baker Hughes, a GE Company. Please register your product at for product support such as the latest software/firmware upgrades, product information and special promotions. Services BHGE provides customers with an experienced staff of customer support personnel ready to respond to technical inquiries, as well as other remote and on-site support needs. To complement our broad portfolio of industry-leading solutions, we offer several types of flexible and scalable support services including: Training, Product Repairs, Extended Warranties, Service Agreements and more. Please visit for more details. Terms and Conditions Sales Terms and Conditions for your recent purchase of a BHGE product, including the applicable product Warranty, can be found on our website at the following link: Typographical Conventions Note: These paragraphs provide information that provides a deeper understanding of the situation, but is not essential to the proper completion of the instructions. IMPORTANT: These paragraphs provide information that emphasizes instructions that are essential to proper setup of the equipment. Failure to follow these instructions carefully may cause unreliable performance. CAUTION! This symbol indicates a risk of potential minor personal injury and/or severe damage to the equipment, unless these instructions are followed carefully. WARNING! This symbol indicates a risk of potential serious personal injury, unless these instructions are followed carefully. Safety Issues WARNING! It is the responsibility of the user to make sure all local, county, state and national codes, regulations, rules and laws related to safety and safe operating conditions are met for each installation. Attention European Customers! To meet CE Marking requirements for all units intended for use in the EU, all electrical cables must be installed as described in this manual. PanaFlow LZ User s Manual 3

4 Preface Auxiliary Equipment Local Safety Standards The user must make sure that he operates all auxiliary equipment in accordance with local codes, standards, regulations, or laws applicable to safety. Working Area WARNING! Auxiliary equipment may have both manual and automatic modes of operation. As equipment can move suddenly and without warning, do not enter the work cell of this equipment during automatic operation, and do not enter the work envelope of this equipment during manual operation. If you do, serious injury can result. WARNING! Make sure that power to the auxiliary equipment is turned OFF and locked out before you perform maintenance procedures on this equipment. Qualification of Personnel Make sure that all personnel have manufacturer-approved training applicable to the auxiliary equipment. Personal Safety Equipment Make sure that operators and maintenance personnel have all safety equipment applicable to the auxiliary equipment. Examples include safety glasses, protective headgear, safety shoes, etc. Unauthorized Operation Make sure that unauthorized personnel cannot gain access to the operation of the equipment. 4 PanaFlow LZ User s Manual

5 Preface Environmental Compliance RoHS The PanaFlow LZ fully complies with RoHS regulations (Directive 2011/65/EU). Waste Electrical and Electronic Equipment (WEEE) Directive BHGE is an active participant in Europe s Waste Electrical and Electronic Equipment (WEEE) take-back initiative (Directive 2012/19/EU). The equipment that you bought has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of your end life equipment in a sound way. The crossed-out wheeled bin symbol invites you to use those systems. If you need more information on the collection, reuse and recycling systems, please contact your local or regional waste administration. Please visit for take-back instructions and more information about this initiative. PanaFlow LZ User s Manual 5

6 Preface [no content intended for this page] 6 PanaFlow LZ User s Manual

7 1.0 Contents Introduction Unpacking the PanaFlow LZ System Site Considerations Installing Cable Glands Specifications Introduction To ensure safe and reliable operation of the PanaFlow LZ flow meter system, it must be installed in accordance with established guidelines. Those guidelines are discussed in this manual and in the flow transmitter User s Manual. IMPORTANT: The PanaFlow LZ flow meter system may be supplied with a variety of GE flow transmitters (XMT1000, XMT910, XMT900, XMT868i, etc.). Be sure to refer to the User s Manual for your specific flow transmitter. Attention! Because the PanaFlow LZ system has the flexibility to use several different GE flow transmitters, the photographs used in this manual may appear slightly different from your system. However, the basic instructions are valid for all PanaFlow LZ systems. WARNING! The PanaFlow LZ flow meter can measure the flow rate of many fluids, some potentially hazardous. The importance of proper safety practices cannot be overemphasized. WARNING! Be sure to follow all applicable local safety codes and regulations for installing electrical equipment and working with hazardous fluids or flow conditions. Consult company safety personnel or local safety authorities to verify the safety of any procedure or practice. Attention! To meet CE Mark requirements, all cables must be installed as described in the flow transmitter User s Manual. CE Mark compliance is required for all systems intended for use in EU countries. PanaFlow LZ User s Manual 1

8 3.0 Unpacking the PanaFlow LZ System Before removing the PanaFlow LZ system from the crate, please inspect the flow meter. Before discarding any of the packing materials, account for all components and documentation listed on the packing slip. The discarding of an important item along with the packing materials is all too common. If anything is missing or damaged, contact GE Customer Care immediately for assistance. 3.1 Identification The PanaFlow LZ meter has up to three separate labels for identification, depending on its configuration. The system is mounted as a single unit. 3.2 Lifting the PanaFlow LZ System Figure 1 below indicates the proper way to attach the lifting straps to any GE flow meter system. Attention! Because the PanaFlow LZ system has the flexibility to use several different GE flow transmitters, the photographs used in this manual may appear slightly different from your system. However, the basic instructions are valid for all PanaFlow LZ systems. WARNING! This is the only approved way to lift a PanaFlow system into position in the pipeline. Never lift the system by the flow transmitter mounted on top of the flowcell. Figure 1: Lifting a Typical GE PanaFlow System 2 PanaFlow LZ User s Manual

9 4.0 Site Considerations 4.1 Local Mounting The flow transmitter accuracy is affected by the flowcell location in the process piping and on the orientation of the transducers. Thus, in addition to accessibility for maintenance, adhere to the following installation guidelines: Locate the flowcell so that there are at least 10 pipe diameters of straight, undisturbed flow upstream and 5 pipe diameters of straight, undisturbed flow downstream from the measurement point (see Figure 2 below). Undisturbed flow means avoiding sources of turbulence in the fluid (e.g., valves, flanges, expansions, elbows, etc.), avoiding swirl, and avoiding cavitation. 10D Flow Direction Figure 2: Minimum Straight Run Pipe Requirements Locate the transducers on a common axial plane along the pipe. Also, locate them on the side of the pipe instead of on the top or the bottom, because the top of the pipe tends to accumulate gas and the bottom tends to accumulate sediment. Either condition will cause unwanted attenuation of the ultrasonic signals. There is no similar restriction with vertical pipes, as long as the fluid flow is upward to prevent free falling of the fluid or a less than full pipe (see Figure 3 below). 5D Horizontal Flowcell Vertical Flowcell GOOD Flow Direction BAD Flow Direction GOOD Flow Direction BAD Figure 3: Good and Bad Flowcell/Transducer Orientations CAUTION! Do not place thermal insulation on or around the transducers, the junction boxes, or the meter electronics. The transducer and junction box act as a heat sink that protects the transducer from high and low temperatures. PanaFlow LZ User s Manual 3

10 4.2 Remote Mounting The standard flow transmitter enclosure is a powder-coated, aluminum, IP67 explosion-proof enclosure. Typically, the enclosure is mounted as close as possible to the transducers. When choosing a site for a remote-mount installation, which is recommended for process temperatures exceeding 150 C, make sure the location permits easy access to the enclosure for programming, maintenance and service. Attention! For compliance with the European Union s Low Voltage Directive, this unit requires an external power disconnect device such as a switch or circuit breaker. The disconnect device must be marked as such, clearly visible, directly accessible, and located within 1.8 m (6 ft) of the transmitter. 4.3 Cable Lengths Locate the flow transmitter as close as possible to the transducers. The maximum distance from the transducers for remote mounting is 1000 ft (300 m) using RG-62 coaxial cable or equivalent. If longer distances are required, consult the factory for assistance. 4.4 Transducer Cables When installing the transducer cables, always observe established standard practices for the installation of electrical cables. Do not route transducer cables alongside high amperage AC power lines or any other cables that could cause electrical interference. Also, protect the transducer cables and connections from the weather and corrosive atmospheres, and be sure to follow the manufacturer's installation guidelines if cable glands are provided. 4.5 Insulation Do not place thermal insulation on or around the transducer locations or the flow transmitter. The enclosures act as heat sinks that protect against high and low temperatures. 4.6 Vibration Exposure Considerations Whenever possible, install the flow transmitter in a location isolated from vibrations. Avoid installing it near equipment that generates low-frequency, high-energy random vibrations. 4.7 Sunlight Exposure The installer should consider and limit exposure of the flow transmitter to direct sunlight. Sunshades should be utilized in extreme environments. 4 PanaFlow LZ User s Manual

11 5.0 Installing Cable Glands When wiring the PanaFlow LZ system in accordance with the instructions in the flow transmitter User s Manual, it is essential that the cable glands be properly installed. To accomplish this, carefully complete the following steps: WARNING! Failure to properly install the cables in the glands will compromise the environmental ratings of the PanaFlow LZ system. Note: These instructions apply to all installations using the GE , , and cable assemblies. 1. Remove the Rubber Boot from the cable gland and slide it back over the cable (see Figure 4 below). Rubber Boot Back Nut Middle Nut Threaded Entry Figure 4: Removing the Rubber Boot 2. Disassemble the Cable Gland (see Figure 5 below). However, DO NOT try to separate the pieces of the Armor Clamp that secures the cable armor, as these pieces are permanently assembled. Armor Clamp Figure 5: Disassembling the Cable Gland PanaFlow LZ User s Manual 5

12 5.0 Installing Cable Glands (cont.) 3. Tighten the Threaded Entry (see Figure 6 below) with a wrench to form a permanent joint. Threaded Entry Figure 6: Tightening the Threaded Entry 4. Insert the Coaxial Cable into the Threaded Entry (see Figure 7 below). Threaded Entry Coaxial Cable Figure 7: Inserting the Coaxial Cable into the Threaded Entry 6 PanaFlow LZ User s Manual

13 5.0 Installing Cable Glands (cont.) 5. Push the Coaxial Cable into the gland until the Armor Clamp is fully inserted into the Threaded Entry section. (see Figure 8 below). Armor Clamp Threaded Entry Figure 8: Inserting the Armor Clamp into the Gland 6. Screw the Middle Nut onto the cable gland to secure the clamped section (see Figure 9 below). Middle Nut Figure 9: Installing the Middle Nut PanaFlow LZ User s Manual 7

14 5.0 Installing Cable Glands (cont.) 7. Tighten the Middle Nut completely by hand (see Figure 10 below). Middle Nut Figure 10: Tightening the Middle Nut by Hand 8. Tighten the Middle Nut with a wrench, but be very careful not to overtighten the nut or the Armor Wires may be broken (see Figure 11 below). Middle Nut Figure 11: Tightening the Middle Nut with a Wrench 8 PanaFlow LZ User s Manual

15 5.0 Installing Cable Glands (cont.) 9. Screw the Back Nut over the Retaining Collar (see Figure 12 below). Back Nut Figure 12: Screwing the Back Nut Over the Retaining Collar 10. Hand tighten the Back Nut to secure the Coaxial Cable and make a weather-tight seal (see Figure 13 below). Back Nut Figure 13: Tightening the Back Nut by Hand PanaFlow LZ User s Manual 9

16 5.0 Installing Cable Glands (cont.) 11. Slide the Rubber Boot down the cable and over the Cable Gland Assembly (see Figure 14 below). Rubber Boot Back Nut Figure 14: Sliding the Rubber Boot Over the Cable Gland Assembly 12. Make sure the Rubber Boot completely covers the Cable Gland and that no tears have occurred in the boot during the assembly process (see Figure 15 below). Rubber Boot Threaded Entry Figure 15: The Completed Cable Gland Assembly 10 PanaFlow LZ User s Manual

17 5.0 Installing Cable Glands (cont.) 13. After the coaxial cables have been properly installed in their cable glands, they must be connected to the terminal blocks inside the flow transmitter enclosure (see Figure 16 below) as follows: Attention! Because the PanaFlow LZ system has the flexibility to use several different GE flow transmitters, the photographs used in this manual may appear slightly different from your system. However, the basic instructions are valid for all PanaFlow LZ systems. a. Connect the transducer wires to their terminal block per the instructions in the User s Manual for your flow transmitter. b. Make sure all of the transducer wires are properly dressed and that they are neatly arranged inside the flow transmitter enclosure. c. Use the flexible strain reliefs inside the flow transmitter enclosure to keep all of the transducer wires clear of the threaded areas. Flexible Strain Relief Figure 16: Terminating the Transducer Cables PanaFlow LZ User s Manual 11

18 6.0 Specifications 6.1 Operation and Performance Fluid Types Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles Flow Measurement Correlation Transit Time model Paths 1-Path: 2 in. to 24 in. (50 mm to 600 mm) pipe 2-Path: 3 in. to 24 in. (80 mm to 600 mm) pipe Pipe Sizes 2 to 24 in. (50 to 600 mm) Pipe Material Carbon steel Stainless steel (316/316L) Accuracy ±0.5% of reading for velocity above 2 ft/s (0.6 m/s) up to 40 ft/s (12.2 m/s) with a resolution of ± 2 mm/s Accuracy statement assumes measurement of a single phase homogeneous liquid with a fully developed symmetrical flow profile passing through the meter. Applications with piping arrangements that create an asymmetrical flow profile may require extended piping straight runs and/or flow conditioning for the meter to perform to this specification. Repeatability ±0.3% of reading typical Range (Bidirectional) ±0.1 to 40 ft/s (0.03 to m/s) Measurement Parameters Dependent upon flow transmitter used. Please refer to individual flow transmitter product data sheet. 6.2 Electronics/Flow Transmitter Temperature Range Operating: -40 to 140 F (-40 to +60 C) Storage: -67 to 167 F (-55 to 75 C) 12 PanaFlow LZ User s Manual

19 6.3 Meter Body and Transducer Pressure Rating Up to maximum allowable flange operating pressure at temperature, per ASME B16.5 Temperature Range WT Transducers:-40 to 175 C (-40 to 347 F) BWT Transducers:-40 to 100 C (-40 to 212 F) -40 to 250 C (-40 to 482 F) Temperature rating of -20 C if used with carbon steel meter body Transducer Material 316L Stainless steel (buffers) Meter Body Materials Carbon steel Stainless steel (316/316L) Certification Electronics/Transducers: Explosion-proof Class I, Division 1, Groups B,C&D ATEX Flameproof II 2 G Ex d IIC T6 IECEx Flameproof II 2 G Ex d IIC T6 (BWT only) Flow Cell: NACE MR0175 and MR0103, PED 2014/68/EU Dimensions Refer to drawings to Drawing Description General arrangement drawing, PanaFlow LZ, 2 & 3, 1 path, 2 traverse, tilted diameter General arrangement drawing, PanaFlow LZ, 4 to 24, 1 path, 1 traverse, tilted diameter General arrangement drawing, PanaFlow LZ, 3 & 4, 2 path, 1 traverse, tilted diameter General arrangement drawing, PanaFlow LZ, 6 to 24, 2 path, 1 traverse, mid-radius PanaFlow LZ User s Manual 13

20 6.4 Transducer Cables Integral Cables Mineral insulated cables with potted cable glands (for North America & Canada hazardous locations) Armored flame retardant coaxial cables with ATEX/IECEx certified cable glands (for European hazardous locations) Remote Cables ATEX/IECEx: Armored RG-62 for ATEX/IECEx US/CAN: Non-armored RG-62, conduit not included Remote cables are not included and must be ordered separately. Maximum cable length is 1000 ft (300 m). 14 PanaFlow LZ User s Manual

21

22 Customer Support Centers U.S.A. The Boston Center 1100 Technology Park Drive Billerica, MA U.S.A. Tel: (toll-free) Ireland Sensing House Shannon Free Zone East Shannon, County Clare Ireland Tel: bhge.com 2017 Baker Hughes, a GE company All rights reserved. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your BHGE representative for the most current information. The Baker Hughes logo is a trade mark of Baker Hughes, a GE company. The GE Monogram is a trademark of the General Electric Company Rev. A

GE Measurement & Control Solutions. Model T9. Ultrasonic Flow Transducer. Installation Guide

GE Measurement & Control Solutions. Model T9. Ultrasonic Flow Transducer. Installation Guide GE Measurement & Control Solutions Flow Model T9 Ultrasonic Flow Transducer Installation Guide 916-080 Rev. B July 2010 Model T9 Ultrasonic Flow Transducer Installation Guide 916-080 Rev. B July 2010

More information

T5 Flare Gas Transducer

T5 Flare Gas Transducer GE Measurement & Control Flow T5 Flare Gas Transducer (Standard and Extended Velocity Range) Installation Guide 916-117 Rev. D November 2014 GE Measurement & Control T5 Flare Gas Transducer (Standard

More information

GE Measurement & Control Solutions. CModel C-RS. Ultrasonic Flow Transducer. Installation Guide

GE Measurement & Control Solutions. CModel C-RS. Ultrasonic Flow Transducer. Installation Guide GE Measurement & Control Solutions Flow CModel C-RS Ultrasonic Flow Transducer Installation Guide 916-077 Rev. C July 2010 Model C-RS Ultrasonic Flow Transducer Installation Guide 916-077 Rev. C July

More information

GE Measurement & Control. Model T17. Ultrasonic Flow Transducer. Installation Guide

GE Measurement & Control. Model T17. Ultrasonic Flow Transducer. Installation Guide GE Measurement & Control Flow Model T17 Ultrasonic Flow Transducer Installation Guide 916-128 Rev. C August 2015 GE Measurement & Control Model T17 Ultrasonic Flow Transducer Installation Guide 916-128

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage

More information

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits. GE Sensing & Inspection Technologies Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically

More information

GE Sensing & Inspection Technologies. Model UTXDR. Panametrics Ultrasonic Flow Transducer. Installation Guide

GE Sensing & Inspection Technologies. Model UTXDR. Panametrics Ultrasonic Flow Transducer. Installation Guide GE Sensing & Inspection Technologies Model UTXDR Panametrics Ultrasonic Flow Transducer Installation Guide GE Sensing & Inspection Technologies Model UTXDR Panametrics Ultrasonic Flow Transducer Installation

More information

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE

INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE INSTALLATION MANUAL XMT MAGNETOSTRICTIVE LEVEL PROBE INDEX INDEX... 2 REVISION INDEX... 2 INTRODUCTION... 3 GENERAL WARNINGS... 3 DESCRIPTION... 4 MAIN COMPONENTS... 5 MECHANICAL INSTALLATION... 6 INSTALLATION

More information

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits. GE Measurement & Control Sentinel LCT Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement Benefits Extremely reliable and highly accurate flowmeter, designed specifically for custody

More information

GE Measurement & Control. DewPro MMY30. User s Manual

GE Measurement & Control. DewPro MMY30. User s Manual GE Measurement & Control Moisture DewPro MMY30 User s Manual A40251540 Rev. C October 2014 DewPro MMY30 Trace Moisture Transmitter User s Manual A40251540 Rev. C October 2014 www.ge-mcs.com 2014 General

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 AB AXIS INDUSTRIES ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2 TECHNICAL DESCRIPTION, INSTALLATION AND USER INSTRUCTIONS PESF2V01 KAUNAS Contents Page SAFETY INFORMATION... 1. APPLICATION FIELD... 2. TECHNICAL

More information

AquaTrans AT600. Panametrics Clamp-on Ultrasonic Liquid Flow Meter. Imagination at work. Version 3 (12/1/14)

AquaTrans AT600. Panametrics Clamp-on Ultrasonic Liquid Flow Meter. Imagination at work. Version 3 (12/1/14) AquaTrans AT600 Panametrics Clamp-on Ultrasonic Liquid Flow Meter Imagination at work. Version 3 (12/1/14) I need a meter that is reliable and user friendly. 2 Introducing the AquaTrans AT600. Simplicity

More information

AquaMaster4 Electromagnetic flowmeter flanged sensor

AquaMaster4 Electromagnetic flowmeter flanged sensor ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION AquaMaster4 Electromagnetic flowmeter flanged sensor The ideal flowmeter for potable water distribution networks, revenue metering and irrigation applications

More information

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS Address all communications and shipments to: FEDERAL SIGNAL CORPORATION Industrial Systems Group 2645 Federal

More information

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module

GETTING STARTED GUIDE NI Channel Sinking Digital Input Module GETTING STARTED GUIDE NI 9421 8-Channel Sinking Digital Input Module This document explains how to connect to the NI 9421. In this document, the NI 9421 with screw terminal, NI 9421 with spring terminal,

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Flow Measurement SITRANS F S Clamp-on

Flow Measurement SITRANS F S Clamp-on Function Operating Principle The SITRANS F S system is a transit-time ultrasonic meter that provides exceptional performance using a non-intrusive clampon approach. Ultrasonic sensors transmit and receive

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

Operator Instructions for Tension Links

Operator Instructions for Tension Links Operator Instructions for Tension Links Page 1 of 9 Table of Contents Introduction... 3 Markings CE... 3 Electromagnetic Compatibility (EMC)... 3 Tension Link Type/Model Number... 3 Supplier... 3 Service...

More information

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS). PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water

More information

Operation Manual for. CU2 Helmholtz Coil System Closed-Loop Module

Operation Manual for. CU2 Helmholtz Coil System Closed-Loop Module Operation Manual for CU2 Helmholtz Coil System Closed-Loop Module Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 4 3. Introduction 4 4. General Description 5 4.1. Front View

More information

CU2 Closed Loop Module

CU2 Closed Loop Module INNOVATION IN MAGNETICS OM-3999/2 Operation Manual for CU2 Closed Loop Module www.bartington.com Table of Contents 1. About this Manual 3 1.1. Symbols Glossary 3 2. Safe Use 4 3. Introduction 4 4. General

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017 ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,

More information

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 485 Annubar Threaded Flo-Tap Assembly Quick Installation Guide 00825-0500-809, Rev DB Threaded Flo-Tap 85 Annubar Rosemount 85 Annubar Threaded Flo-Tap Assembly Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3: Install

More information

1000 Series Piston Type Differential Pressure Gauges

1000 Series Piston Type Differential Pressure Gauges 1000 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate GETTING STARTED GUIDE NI 9201 8 AI, ±10 V, 12 Bit, 500 ks/s Aggregate This document explains how to connect to the NI 9201. In this document, the NI 9201 with screw terminal, NI 9201 with spring terminal,

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions 2562179B REV. B 818 Printed in USA 2013-2018 Federal Signal Corporation. All rights reserved. Limited Warranty

More information

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Rosemount 585 Annubar Flanged Flo-Tap Assembly Quick Installation Guide 00825-0200-585, Rev AA Flanged Flo-Tap 585 Annubar Rosemount 585 Annubar Flanged Flo-Tap Assembly Start Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3:

More information

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18) SPECIFICATIONS MV Series Bulletin SS02016 Issue/Rev. 2.0 (2/18) Smith Meter Turbine Meters The Smith Meter MV Series Turbine Meter is intended for the measurement of crude oils and other products having

More information

Operating Instructions

Operating Instructions Resistance Thermometer Clamp-on technology for temperature measurement on pipes, Type Series GA261x Operating Instructions 1 General Information... 2 1.1 General Safety Notes... 2 1.2 Intended Use... 2

More information

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:

More information

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator ACCORD CONTROLS Aviator II Valve Controller Installation Operation Maintenance FCD ACENIOM0100-02 Mechanical Installation: Installation is best performed with the NAMUR mounting kits. These kits allow

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

Rosemount 485 Annubar Flanged Assembly

Rosemount 485 Annubar Flanged Assembly Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar Rosemount 85 Annubar Flanged Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Assemble and Check

More information

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48. support@i2systems.com www.i2systems.com Electrical Specifications PARAMETER Input Power VALUE 8 Watts* / Ft Input Voltage 120-277V AC, 50/60 Hz Max. Fixture Run Length LED Color (CCT) 8 Watts: 120VAC:

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous

GETTING STARTED GUIDE NI AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous GETTING STARTED GUIDE NI 9244 3 AI/1 Neutral, 400 Vrms L-N/690 Vrms L-L, 24 Bit, 50 ks/s/ch Simultaneous This document explains how to connect to the NI 9244. Note Before you begin, complete the software

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Condensed Version of Operator s Manual For The VL600 Series Flowmeters Condensed Version of Operator s Manual For The VL600 Series Flowmeters Warranty Agreement JTEC Associates warrants this product to be in good working order for a period of twelve (12) months from installation.

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Instruction Manual Form 5116 Types 1808 and 1808A July 2010 Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators! Warning Failure to follow these instructions or to properly install

More information

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly

CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly Product Specification 03421 (Revision NEW, 5/2015) CPC DX (CPC Dual Transfer Skid) Redundant current to pressure converter assembly Applications The CPC-DX (current-to-pressure converter dual transfer)

More information

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous

GETTING STARTED GUIDE NI AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous GETTING STARTED GUIDE NI 9223 4 AI, ±10 V, 16 Bit, 1 MS/s/ch Simultaneous This document explains how to connect to the NI 9223. Note Before you begin, complete the software and hardware installation procedures

More information

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing

More information

BARTON 7400 Precision Gas Turbine Flow Meters

BARTON 7400 Precision Gas Turbine Flow Meters TECHNICAL SPECIFICATIONS BARTON 7400 Precision Gas Turbine Flow Meters BARTON Model 7400 Precision Turbine Flow Meters are designed for gas service in a wide range of industrial, commercial, pipeline and

More information

Lamp kit. Installation manual SIM 7 series R

Lamp kit. Installation manual SIM 7 series R Lamp kit Installation manual SIM 7 series R9841805 R59770113/01 12/06/2009 Barco nv Simulation Division Noordlaan 5, B-8520 Kuurne Phone: +32 56.36.82.11 Fax: +32 56.36.84.86 E-mail: info@barco.com Visit

More information

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4 1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

NI 9251 with mini XLR

NI 9251 with mini XLR GETTING STARTED GUIDE NI 9251 with mini XLR 2 AI, 3 Vrms, 24 Bit, 102.4 ks/s/ch Simultaneous, AC/DC Coupling This document explains how to connect to the NI 9251 with mini XLR. Note Before you begin, complete

More information

Installation and Operating Manual

Installation and Operating Manual Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing

More information

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount 285 Annubar Pak-Lok Assembly Quick Installation Guide 0025-0100-02, Rev AA Pak-Lok 25 Annubar Rosemount 25 Annubar Pak-Lok Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Weld Mounting Hardware

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF VERSION UF-5xx d INSTALLATION MANUAL ISO 9001:2008 CONTENTS Page INTRODUCTION... 3 1. SAFETY INSTRUCTIONS... 4 2. MOUNTING PREPARATION... 4 3. MOUNTING REQUIREMENTS...

More information

Manual Turbine Flow Meters HM Series

Manual Turbine Flow Meters HM Series www.kem-kueppers.com info@kem-kueppers.com Manual Turbine Flow Meters HM Series 2 Version Manual-Version HM_M_EN_170101_E002 Index 3 Index 1. GENERAL INFORMATION... 4 1.1. General... 4 1.2. Evaluation...

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

Cylindrical Silencers

Cylindrical Silencers Cylindrical Silencers A200 Series and 300 Series Installation and Operation Manual Rev. B (c) Copyright 2012, GT Exhaust, Inc. All Rights Reserved Published: April 30, 2012 NOTICE The instructions herein

More information

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL v1.0 REV. 02/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUTIONS STANDARDS TO FOLLOW 02. THE AUTOMATISM COMPONTS TECHNICAL SPECIFICATIONS

More information

SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 *

SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 * SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 * PRODUCT: Top Fuel Front Wing Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 11 Applications For direct installation into the process Machine building

More information

Power-Limiting Cables

Power-Limiting Cables Power-Limiting Cables This section provides general design guidelines for power-limiting heat-tracing systems installed on insulated metal pipes. For other applications or design assistance, contact your

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

Masoneilan * Series

Masoneilan * Series Masoneilan * 41005 Series Heavy Duty, Globe-Style Control Valves Dependable globe-style control valve solutions for maximum performance in severe service conditions bhge.com 41005 Series Cage-Guided Globe

More information

Installation Instructions for Appleton Mercmaster LED Luminaire

Installation Instructions for Appleton Mercmaster LED Luminaire 650559-000 INSTRUCTION SHEET Installation Instructions for Appleton Mercmaster LED Luminaire FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS. Product Safety Signal

More information

GE Panametrics Ultrasonic Flow Meter

GE Panametrics Ultrasonic Flow Meter R Application Note GE Panametrics Ultrasonic Flow Meter Part II Transducer Installation Physical Installation Requirements and Pipe Preparation 1. Install the transducers on a straight run of pipe free

More information

Safety Shock Absorbers SCS33 to SCS64

Safety Shock Absorbers SCS33 to SCS64 Safety Shock Absorbers SCS33 to SCS64 1 Operating Instruction SCS33-25EU SCS33-50EU SCS45-25EU SCS45-50EU SCS45-75EU Rod Button SCS64-50EU SCS64-100EU SCS64-150EU Integrated Rod Seals Main Bearing Content

More information

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016 Rosemount 405 Compact Primary Element 00825-0100-4810, Rev HA NOTICE This guide provides basic guidelines for Rosemount 405. It does not provide instructions for configuration, diagnostics, maintenance,

More information

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood 2 SAFETY Please also read through these notes carefully. 2.1 General potential danger due to: a. Failure to observe the instructions

More information

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual 362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names

More information

289 Series Relief Valves

289 Series Relief Valves Instruction Manual Form 174 89 Series May 013 89 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion and/or

More information

TIDALFLUX 2300 F Quick Start

TIDALFLUX 2300 F Quick Start Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS

More information

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Mid-West Instrument. Series 700 Wet/Wet Installation and Operating Instructions. Differential Pressure Transmitter Mid-West Instrument IM_700/A Series 700 "Wet/Wet" Installation and Operating Instructions Differential Pressure Transmitter 6500 Dobry Dr. Sterling Heights, MI USA Toll Free: 800-648-5778 Ph 586-254-6500

More information

INSTALLATION RULES for SCS/SENSOR Pt100

INSTALLATION RULES for SCS/SENSOR Pt100 INSTALLATION RULES for SCS/SENSOR Pt100 1MN0118 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it

More information

SeekTech Inductive Clamp

SeekTech Inductive Clamp Inductive Clamp Manual SeekTech Inductive Clamp! Read this Operator s Manual carefully before using this tool. Failure to understand and follow the contents of this manual may result in electrical shock,

More information

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS VARIFUEL2 140-65 MAINTENANCE AND REPAIR INSTRUCTIONS MOTORTECH Gas Regulation P/N 01.50.008-140-65-EN Rev. 06/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes User Guide IM/TORBAR-EN Rev. D Torbar The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement, gas and liquid

More information

Model DFX Doppler ultrasonic flow meter

Model DFX Doppler ultrasonic flow meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger

More information

Proximity Transmitters, and Seismic Vibration Transmitters

Proximity Transmitters, and Seismic Vibration Transmitters TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The

More information

SFI SPECIFICATION 14.3 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 14.3 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 14.3 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Nitro-Methane Fuel Supercharger Restraint Devices 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and

More information

Installation and Operation Manual. Value Switch Package (VSP and VSP+)

Installation and Operation Manual. Value Switch Package (VSP and VSP+) Installation and Operation Manual Value Switch Package (VSP and VSP+) Table of Contents Table of Contents Introduction and Safety... 2 Safety message levels... 2 User health and safety... 2 Transportation

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS VARIFUEL2 200-120 MAINTENANCE AND REPAIR INSTRUCTIONS MOTORTECH Gas Regulation P/N 01.50.008-200-120-EN Rev. 06/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management

More information

Net +Plus Connection Code

Net +Plus Connection Code Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at

More information

Logix 3800 Digital Positioner

Logix 3800 Digital Positioner Logix 3800 Digital Positioner Maximize production and reduce operating costs Experience In Motion Experience In Motion Solving the toughest challenges in flow management Flowserve is working with the world

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Rosemount 3095FT MultiVariable Flow Data Logger

Rosemount 3095FT MultiVariable Flow Data Logger Quick Installation Guide Rosemount 3095FT Rosemount 3095FT MultiVariable Flow Data Logger Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set Jumpers and Switches Step 4: Connect

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS C75-100-A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS DESCRIPTION The C75-100-A is a NEMA 4X-rated gland kit used to transition heating cables into a junction box when making connections off of a

More information

These installation and maintenance instructions must be read in full and completely understood before the installation!

These installation and maintenance instructions must be read in full and completely understood before the installation! These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions

More information