1 INSTALLATIN MANUAL This manual covers the following models: WW60W Wireless Wire Applications uide Wireless Wire replaces 4V wiring. When the input module is energized with 4V on any terminal the paired terminal on the output module closes. There are also terminals on the output module that when energized with 4V will close the paired terminals on the input module. Input module up to: 7 terminal inputs / terminal outputs utput module up to: 7 terminal outputs / terminal inputs Power Type Hardwire (ommon Wire) Table of ontents Wireless Modules Quick Reference Installation Tips Subbase Installation Wiring Mounting the Wireless Modules Specifications & ontact Info Page A trained, experienced technician must install this product. arefully read these instructions. You could damage this product or cause a hazardous condition if you fail to follow these instructions. Una versión española de este manual puede ser descargada en Need Help? For assistance with this product please visit or call Pro ustomer are toll-free at 888-Proiaq (776-47) during normal business hours (Mon-Fri 9 AM - 6 PM Eastern) U.S. Registered Trademark. Patents pending. opyright 00 PR IAQ, Inc. All rights reserved. Rev. 04
2 WIRELESS MDULES QUIK REFERENE etting to know the Wireless Wire Modules Important: oth wireless modules must have 4VA power connected on R and. These modules can only switch 4VA power. Wireless signal is one way from Input Module to utput Module for all terminals except Input and Input. Terminals Input and Input have a one way signal to utput and utput. onnecting Wireless Wire. Hold utput Module utton for 5 seconds. Terminal Lights lue Indicator Light Module utton.. 4. The lue Indicator Light will flash while waiting for a signal from the Input module. Hold Input Module utton for 5 seconds. The lue Indicator Light will be continuously on to show communication has been established. Notes on Wireless Wire When the on the Input Module receives a 4VA signal it sends a wireless command to the utput Module and it closes the utput Module. This logic also applies to, W,,, &. When the Input on the utput Module receives a 4VA signal it sends a wireless command to the Input Module and it closes the utput terminal. This logic also applies to Input /utput. The terminal lights on the front of the module indicate when the associated relay is closed. The blue indicator light will be on if communication is established and working. The blue indicator light flashes when the unit is sending a signal. The blue indicator light will be off if the module has not communicated for hour or 4VA has been lost. All inputs will be turned off after hour if the communication link is continuously lost. Visit our website at to learn more about our other wireless family of products
3 INSTALLATIN TIPS Wireless Modules - asement Installation ATTI INSTALLATIN N THE NEXT PAE Wireless Range Range between the WW60W Input module and the WW60W utput module is up to 00 feet with no obstructions and up to 50 feet in standard residential construction. To extend the range try placing the modules closer together and/or further away from large metal objects. EST ETTER N D PR Tip Do not install the wireless modules in locations: That are behind a chimney Where temperature could exceed 0ºF Where exposed to rain or snow Where exposed to extreme hot or cold NTE: The wireless modules are NT weatherproof.
4 INSTALLATIN TIPS Wireless Module - Attic Installation When performing an attic installation, instead of placing the wireless module in the attic, locate the closet nearest to the air conditioning unit. Then mount the wireless module high on the wall inside the closet or on the ceiling of the closet. This location will insure the wireless module is below the 0ºF maximum ambient temperature specification. Attic Living Space loset Wireless Module - utdoor Installation utside Plastic Weatherproof ox YES Inside PREFERRED Note: Installing the modules in a conditioned space is preferred. utdoor installations should only occur in climates that remain above freezing. N PR Tip Do not install the wireless modules in locations: That are behind a chimney Where temperature could exceed 0ºF Where exposed to rain or snow Where exposed to extreme hot or cold NTE: The wireless modules are NT weatherproof. 4
5 SUASE INSTALLATIN Mounting the wireless module subbase For vertical mount put one screw top and one screw bottom. For horizontal mount put one screw left and one screw right. Wiring Note: Wire the wireless module s subbase the same way you would wire a hardwired thermostat subbase. Input Module Vertical mount UP Horizontal mount ut ut utput Module Vertical mount Horizontal mount UP Vertical mount Horizontal mount In In Horizontal mount Vertical mount Note: oth modules must be hardwired ( and R terminals connected to 4VA power). 5
6 WIRIN Thermostat To Equipment 4 5 Install the Input Module in a location that is convenient to wire the thermostat. onnect 4VA to R and on the input module. Install the output module in a location that is convenient to wire to the system control board. (This is the board that normally has the thermostat wire connected to.) onnect 4VA to the R and on the output module. onnect the terminals from the thermostat to the appropriate terminals on the input module. ( to, to, etc...) onnect the terminals from wireless wire utput Module to system control board just like a thermostat. Test the system. Thermostat Power Supply R RH ut Wireless Wire Input Module R L L (HT) ut Wireless Wire utput Module FAN RELAY R L L (HT) Wiring Note: Wire the wireless module s subbase the same way you would wire a hardwired thermostat subbase. MPRESSR RELAY In HEAT RELAY In Important: Turn off power while wiring. 6
7 WIRIN Air Handler to Multi-Stage ompressor 4 5 Install the Input Module in a location that is convenient to wire to the system control board. (This is the board that normally has the wire from the condensing unit connected to it.) onnect 4VA to the R and on the output module. Install the output module in a location that is convenient to wire to the compressor relays. onnect the terminals from the furnace control board to the appropriate terminals on the input module. ( to, etc...) onnect the terminals from wireless wire utput Module to the compressor relays. Test the system. Furnace oard Power Supply R RH ut Wireless Wire Input Module R L L (HT) ut Wireless Wire utput Module ST STAE RELAY ND STAE RELAY R L L (HT) Wiring Note: for Heat Pumps with a defrost cycle connect the defrost terminal to Input on the utput Module and connect ut on the Input Module to the appropriate terminal on the air handler. In In Important: Turn off power while wiring. 7
8 MUNT THE WIRELESS MDULES Mount the Wireless Modules Align the 4 tabs on the subbase with corresponding slots on the back of the wireless modules. Then push gently until the thermostat or base module snaps in place. Note: The wireless modules can be wired from the back or the bottom. 8
9 SPEIFIATINS & NTAT INFRMATIN Specifications Load rating Power source amp per terminal,.5 amp maximum all terminals combined 8 to 0 VA, NE lass II, 50/60 Hz for hardwire (common wire) perating ambient perating humidity Frequency Dimensions +ºF to +ºF ( 0º to +50º ) 90% non-condensing maximum 96 MHz 4.4 W x 4.4 H x.75 D Pro IAQ Inc. S. lenstone Suite -00 Springfield, M Toll-free: -888-Proiaq (776-47) Toll Number (utside the USA): Web: Hours of peration: Monday - Friday 9 AM - 6 PM Eastern 9
FAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation
Model Installation Instructions Application The Model is designed to add additional control wiring between the thermostat and indoor unit or between the indoor unit and outdoor unit. Before Installing
More informationMODEL SMZ-SW ZONE CONTROL SYSTEM
DuroZone MODEL SMZ-SW ZONE ONTROL SYSTEM DuroZone is a division of orporation PART# 35226 PART# 35227 SMZ-2SW/SMZ-3SW INSTALLATION INSTRUTIONS ongratulations on purchasing a DuroZone SMZ ontrol System.
More information- Wiring Brochure tekmarnet 4 Thermostat 545
- Wiring Brochure tekmarnet 4 545 W 545 12/08 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Layout Brochure ough-in 4 Wiring Brochure
More information1968 Chevrolet Corvette with & without Factory Air Chevrolet Corvette without Factory Air
an IS 900:008 Registered ompany 968 hevrolet orvette with & without Factory Air 969-76 hevrolet orvette without Factory Air ontrol Panel onversion Kit (47370) 8865 Goll St. San Antonio, TX 7866 Phone:
More informationTwo temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser
The ZC 107 Zone Control System was designed to provide the perfect comfort control within the home. At the same time it was designed to make an airconditioning system work more efficiently and thereby
More informationSECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls
SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe
More informationTECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationTECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES
TECHNICAL GUIDE Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE NATURAL GAS 40-130 MBH INPUT EFFICIENCY RATING CERTIFIED DESCRIPTION These high efficiency, dedicated
More informationDZ11S Commercial & 10-Ton, Three-Phase
DZ11S ommercial 7.5- & 10-Ton, Three-Phase Split System Heat Pump 11 EER / 3.3 OP / R-410A ontents Nomenclature... 2 Product Specifications... 3 Expanded ooling Data... 4 Expanded Heating Data... 12 AHRI
More informationR4H4. Product Specifications
ENVIRONMENTALLY SOUND REFRIGERANT R4H4 Product Specifications EFFICIENT 14 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationInstaller Guide smart connect
Installer Guide smart connect TM 7490 Wireless Remote Outdoor Sensor Please read all instructions before proceeding. The wireless remote outdoor sensor monitors temperature at a remote outdoor location
More informationLISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES
P G 036-21342-002 Rev. C (0902) TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) U R MA N U F A CT R E C E CE R T I F R T I UN I TA RY A R I F I
More information- Wiring Brochure Universal Reset Module 422
- Wiring Brochure Universal Reset Module 422 W 422 03/09 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationSnapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle
LX5 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
More informationSafety & Installation Instructions
Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting
More informationInstallation Manual GT500 GT500R RAB
Installation Manual GT500 GT500R RAB How Does Gotcha Work? Gotcha s infrared sensor sees small temperature changes caused by the motion of people or cars within its protection zone and turns on lights
More informationCable/Gate Lock INSTALLATION MANUAL
ACCESS CONTROLS WIRELESS Cable/Gate Lock INSTALLATION MANUAL This convenient battery powered wireless lock has many uses, including; multiple user access to property, securing items such as boats or trailers
More informationREPLACEMENT PARTS MANUAL
REPLACEMENT PARTS MANUAL WHA-A WHA-B WHA-C WALL-MUNTED PACKAGED HEAT PUMP WHADA WHADB WHADC WHA-A WHA-B WHA-C Models: WHADA WHADB WHADC W0HA-A W0HA-B W0HA-C W0HADA W0HADB W0HADC Contents Description Page
More informationTECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHX SERIES YTG-A-0409
TEHNIAL UIDE SINLE PIEE AIR HANDLERS FR USE WITH SPLIT-SYSTEM LIN & HEAT PUMPS MDELS: AHX SERIES DESRIPTIN This air handler line offers the ultimate in application flexibility. The AHX (high efficiency
More informationR1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up
Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in
More informationINSTALLATION GUIDE OWNER S GUIDE
INSTALLATION GUIDE OWNER S GUIDE REMOTE STARTER MODELS RS92 / RS92E CONTENTS System Features... 1 System Components... 1 Required Tools... 1 Technical Assistance... 1 Before You Begin... 1-2 Precautions...
More informationINSTALLATION GUIDE OWNER S GUIDE
INSTALLATION GUIDE OWNER S GUIDE REMOTE STARTER MODELS RS202/RS202E CONTENTS System Features...1 System Components...1 Required Tools...1 Technical Assistance...1 Before You Begin...2 Precautions...2 Testing
More informationG861 Series Integrated Function. Direct Spark Ignition Control
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS TEC20 TEC20H ELECTRONIC CONTROLLER BARD MANUFACTURING COMPANY Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. Manual: 2100-306D Supersedes: 2100-306C File: Volume
More informationEnvirotainer RAP e2 Container Operations Manual
Operations Manual This manual is valid for: RAP container, P/N 140010R-() Version 1.5: 2016-04-15 www.envirotainer.com Operations Manual RECORD OF REVISION RECORD OF REVISION VER. NO. ISSUE DATE REVISION
More informationDZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A
DZ11TA ommercial 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/13-13.5 IEER /3.3 OP/R-410A ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Expanded Heating Data...12
More informationV4043 and V4044 Motorized Valves
V03 and V0 Motorized Valves INSTALLATION INSTRUCTIONS FEATURES V0 These valves consist of an actuator motor and valve assembly for controlling the flow of hot or cold water. The V03 provides 2-position,
More informationINSTALLATION GUIDE OWNER S GUIDE
INSTALLATION GUIDE OWNER S GUIDE REMOTE STARTER MODEL RS82 CONTENTS System Features... 1 System Components... 1 Required Tools... 1 Technical Assistance... 1 Before You Begin... 1-2 Precautions... 2 Making
More informationSLIMZONE CLASSIC /
SLIMZONE CLASSIC 2701-001 / 2701-006 ZONE CONTROL SYSTEM INSTALLATION AND OPERATION MANUAL TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 IMPORTANT NOTE...1 1.2 FEATURES...1 1.3 SAFETY INSTRUCTIONS...1 2. APPLICATION
More informationR2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz
3 PHASE HEAT PUMP COMPONENT 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors on all models Compressors contain proper charge of mineral oil Suction line accumulator
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model WRCPF-KIT IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this device. For your safety, always comply with all warnings and safety instructions
More informationIMPORTANT SAFETY INFORMATION:
Owner s Manual Model WRCPF-KIT IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this device. For your safety, always comply with all warnings and safety instructions
More informationREPAIR PART INSTALLATION INSTRUCTIONS
REPAIR PART INSTALLATION INSTRUTIONS ONTROL REPAIR KIT FOR (S1-37323870001) ODELS E*FH / E*EB / E*S 361816-UAI-A-0208 FIGURE 1: Demand Defrost ontrol odule GENERAL The YorkGuard VI Demand Defrost control
More informationWelcome to your CM Sensor kit!
Welcome to your CM Sensor kit! For additional help and resources, visit: www.churchmutual.com/sensors/help Getting started Your quick and simple guide to 4/7 temperature and water protection. Your CM Sensor
More informationMINI-MASTERZONE ZONING SYSTEM. MMP2 For Plug-In Damper Motors. Installation and Operating Instructions. 2 Zones. Controlling Your Comfort Room by Room
MINI-MASTEZONE ZONING SYSTEM MMP2 For Plug-In Damper Motors 2 Zones Installation and Operating Instructions ontrolling Your omfort oom by oom MINI-MASTEZONE ZONING SYSTEM MMP2 Features System Mode Indicator
More informationSP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control
SP-32, SP-32D SP-33, SP-33D SP-34, SP-34D Single Stage Temperature Control Description The SP-3x and SP-3xD series of controls are single stage, general purpose, temperature controls with wide application
More informationUARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60
TECHNICAL GUIDE GUARDIAN SERIES DRY SHIP AIR CONDITIONER CONDENSING UNITS SHIPPED WITH NITROGEN CHARGE ONLY 13 SEER R-22 1 PHASE 1.5 THRU 5 NOMINAL TONS MODELS: GCGD18 THRU 60 UARDIAN Due to continuous
More informationTECHNICAL GUIDE 16 SEER 2-5 TON AIR CONDITIONING SPLIT-SYSTEM COOLING H4TS024 H4TS030 H4TS036 H4TS048 H4TS060 DESCRIPTION FEATURES MODELS:
036-21023-002 Rev A (5/00) TECHNICAL GUIDE 16 SEER 2-5 TON CONDITIONING SPLIT-SYSTEM COOLING DESCRIPTION The HTS Stealth series condensing units use Twin Single compressor technology to provide cooling
More informationSnapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle
LX10 Snapshot OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle USER MANUAL Chauvet, 3000 N 29 th Ct, Hollywood, FL 33020 U.S.A.
More informationPANcharge1k Battery Charger User's Manual
PANcharge1k Battery Charger User's Manual Ver.1.00E Table of Contents 1. Important Safety Instructions... 3 1-1 General Safety Precautions... 3 1-2 Battery Precautions... 3 1-3 Electromagnetic Disturbance...
More informationUser Manual. E11-N1EA LED Wireless RGBW A19 Bulb. LED + Smart Control
User Manual E11-N1EA LED Wireless RGBW A19 Bulb LED + Smart Control Features COLOR/CCT/ON/OFF/DIMMING via mobile APP. 16 million color options available. Bulb is also white tunable from 2000K to 6500K.
More informationKit User Guide. Wireless Digital Controller User Guide
Kit 72000 Wireless Digital Controller User Guide UG-681 (03902) ECR 6629 User Guide For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.
More informationCOMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012
COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER
More informationTECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS. DESCRIPTION FEATURE
TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FR USE WITH SPLIT-SYSTEM LIN & HEAT PUMPS MDELS: AHE18 THRU 60* DESRIPTIN The Air Handler line offers the ultimate in comfort, sound and application
More informationBITZER Liquid Injection Guidelines for CSH Compressors
BITZER Liquid Injection Guidelines for CSH Compressors Liquid Injection Additional cooling may be required during reduced capacity operation, high condensing and / or low evaporating temperatures. Direct
More informationTrueDRY DR65/DR90/DR120
TrueDRY DR65/DR90/DR120 Ventilating Dehumidification System DR65 Specifications Part Number: DR65A2000 Blower: Supply Voltage: Amps: 160 CFM @ 0.0 in. WG 100 CFM @ 0.6 in. WG 120 VAC; 60 Hz. 5.2 A Power
More informationHEAVY DUTY POWER RELAYS FEATURES
VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for
More informationINSTALLATION AND OPERATION INSTRUCTIONS
120 Cat. No. H8863 Model: WS-S-TMR INSTALLATION AND OPERATION INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This remote
More informationHGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology
HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951
More informationInstallation and Operations Manual
Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com
More informationVC2, VC4, VC60, VC8 ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES SPECIFICATIONS INSTALLATION INSTRUCTIONS
ON-OFF ACTUATOR FOR VC SERIES BALANCED HYDRONIC VALVES INSTALLATION INSTRUCTIONS Power consumption: 6 Watts Max. at nominal Voltage (during valve position change). Use 24 V Class 2 transformer and provide
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be
More informationSERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012
100V to 1000V DC 100A to 5000A DC SERIES 50 MODELS 506 & 5012 6 Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems Applications: Electrocoating Ion Nitriding Magnet
More informationAutoranging Industrial Multimeter
Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationINSTALLATION GUIDE OWNER S GUIDE
INSTALLATION GUIDE OWNER S GUIDE STARTER IMMOBILIZER MODEL 102 CONTENTS System Features... 1 Technical Assistance... 1 System Components... 1 Required Tools... 1 Precautions... 1 Making Wiring Connections...
More information- Wiring Brochure Universal Reset Module 422e
- Wiring Brochure Universal Reset Module 422e W 422e 01/08 1 Information Brochure hoose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in
More informationStreamline 3-Knob Horizontal Panel, Anodized RUA
an ISO 900:2008 Registered ompany Streamline 3-Knob Horizontal Panel, Anodized 49223-RUA 8865 Goll St. San Antonio, TX 78266 Phone: 20-654-77 Fax: 20-654-33 www.vintageair.com 90223-RUA REV B 09/22/4,
More informationProduct Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL
SYSTXBBECC01-B Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr
More informationProduct Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL
SYSTXCCITC01---B Infinityr System Control Product Data A11577 NOTE: Infinityr System Control compatible with Infinityr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr
More informationResidential generator set RS Air-Cooled Series RS13A/AC Model GSBA
Specification sheet Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA Features and benefits Very quiet operation Internet remote monitoring and email notification Automatic load management
More informationatalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:
atalog Welcome to.com! Contact us... Email: sales@ato.com Tel: +1 800-585-1519 (Toll-free) Website: ZMQ2E Series Dual Power Automatic Transfer Switch (ATS) Applications ZMQ2E dual auto transfer switch
More informationResidential generator set RS Air-Cooled Series RS13A/AC Model GSBA
Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA Features and benefits Very quiet operation Internet remote monitoring and email notification Automatic load management - The intelligent
More informationDMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER
E363518 DMR 3005 WM ONE ZONE WIRELESS DIMMER RECEIVER 20725 NE. 16 AVE. #A-33 MIAMI, FLORIDA 33179 Tel: (305) 652-2599 Fax: (305) 650-8812 www.lumiron.com Email: sales@lumiron.com 1 Benefits and Features
More informationC4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT C4A3 SoftSound SX 2300 Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt,
More informationGrow With Me RC Rally
Grow With Me RC Rally Model Number 77306 Please keep this instruction sheet for future reference, as it contains important information. Requires four "C" (LR14) alkaline batteries for control tower; four
More informationSAVE THIS MANUAL FOR FUTURE REFERENCE.
Instruction Manual Weather Station CONTENTS Unpacking Instructions... 2 Package Contents... 2 Product Registration... 2... 2... 3 Setup... 5 Sensor Setup... 5... 6... 7... 7... 7... 8 Using the Weather
More informationThis section is specifically about safety matters
6 4 ) 1 6 4 1 -, 1 8-4 6-4 1 6 4 7 + 6 1 ) 7 ) - -, - - + 6. 4 ) 6 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information and precautions
More informationSO-2BON- - SO-2BOI- - 2-Button Wallstation with Occupant Sensor Connection
SO-ON- - SO-OI- - -utton Wallstation with Occupant Sensor onnection Off SO-ON-WH-EGN (Non-insert version) olor and Engraving odes LEDs Engraving Off so-bo 5..06 Description Often used in entryways to select
More informationCOMFORT FOR LIFE DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR
20 SERIES - ENHANCED CAPACITY DUCTLESS WALL & FLOOR MOUNTED HIGH-EFFICIENCY HEAT PUMP 20 SEER UP TO 12.5 HSPF UP TO 13 EER INVERTER, VARIABLE-SPEED COMPRESSOR COMFORT FOR LIFE www.daikincomfort.com "I'm
More informationLC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE
LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101194 Document revision: D DCN number: 105128 Date: 3/23/2006 1840 Industrial Circle Longmont, CO 80501 Fax: 303-678-7504 Tel: 303-678-7500
More informationZap 5LX-S. Model No.: BH9938U-5-2. Questions or Concerns? (855)
Zap 5LX-S Model No.: BH9938U-5-2 Questions or Concerns? (855) 686-3835 support@etekcity.com Thank You. Thank you for purchasing the Zap 5LX-S Remote Outlet Switch by Etekcity. We are dedicated to providing
More informationLED Pinspot 2. Snapshot. User Manual
LED Pinspot 2 Snapshot Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User Serviceable Duty Cycle User Manual 3000 N 29 th Ct, Hollywood, FL 33020
More information203365A 120 Vac to 220/240 Vac Conversion Kit For Electronic Air Cleaners
065A 0 Vac to 0/0 Vac Conversion Kit For Electronic Air Cleaners Application The 065A Conversion Kit changes the 0 Vac, 60 Hz to 0/0 Vac, 50/60 Hz. The kit includes a transformer and two screws. The line
More informationPAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01
PAB SERIES 3thru6-1/3Ton Belt Drive CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT 10 SEER SINGLE PACKAGE Electric cooling, self contained for year-round comfort. Systems can be installed on roof top
More informationLED Pinspot 2. Snapshot. User Manual
LED Pinspot 2 Snapshot Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave Auto-ranging Power Supply Replaceable Fuse User-Serviceable User Manual 5200 NW 108th Avenue, Sunrise, FL 33351 U.S.A.
More informationDMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc.
omputer Weld Technology, Inc. 070 Old ammel N Houston Rd. Houston, TX 77086 Telephone: (7) 46-8 Fax: (7) 46-50 DM-500 TM D Motor Drive ontrol Operation / Installation Manual Manual Part Number: S8M500
More informationMini Multimeter with Non-Contact Voltage Detector (NCV)
Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82315 REL CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this
More informationHave a Bright Day! Nicholas Harmon President, Verilux, Inc.
VD03 Dear Customer, Thank you for purchasing the Verilux Heritage Deluxe Natural Spectrum Desk Lamp. You have received a quality product, backed by a one-year limited warranty. As a Verilux customer, your
More informationCorporate Partners Committee Smart Meter Data Access Use Case. June 21, 2011
Corporate Partners Committee Smart Meter Data Access Use Case June 21, 2011 Jane & Joe Jane and Joe live in a modern home Both of them have day jobs away from home They have a teenager son living with
More informationLow-Water Auto Shutoff Pump 420 Gallons Per Hour
Low-Water Auto Shutoff Pump 420 Gallons Per our REMINDER ALL 1-888-755-6750 EFORE RETURNING TO STORE. PAKAGE ONTENTS ITEM #PF420AS Questions, problems, missing parts? efore returning to your retailer,
More informationMini Multimeter with Non-Contact Voltage Detector (NCV)
Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.
More informationBAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)
Overview The BAPI-Stat 4 Style room unit is available as a humidity only sensor or as a combination temperature and humidity sensor with optional LCD display, temperature setpoint adjustment and occupant
More information24V INSTALLATION INSTRUCTIONS. Optimized Light Output Chart 12V
INSTALLATIN PRCEDURES Please read all instructions prior to installation. Product should be installed by a qualified electrician. Prior to installation, pleast test all tapelight components to ensure no
More informationInstallation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.
Installation Guide DigiTract 4 Two Stage Heat/Cool Comfort Control System Part #DT4MAN Rev. October 2013 Zoning Systems That s all we do. TABLE OF CONTENTS...Page INTRODUCTION...1 SYSTEM DESCRIPTION...1
More informationResidential generator set RS Air-Cooled Series RS13A/AC Model GSBA
Specification sheet Residential generator set RS Air-Cooled Series RS13A/AC Model GSBA Features and benefits Very quiet operation Internet remote monitoring and email notification Automatic load management
More informationModulating Furnace Information. Warning on Meter Setting - Read First!
Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56
More informationTECHNICAL GUIDE. WARRANTY 1-year limited parts warranty. Plus an additional 4-year compressor warranty. FEATURES
TEHNIAL UIDE SPLIT-SSTEM HEAT PUMPS 10 SEE BHS018 THU 060 (1.5 THU 5 NMINAL TNS, 1 PH) E*BA-(T,) 036 THU 090 (3 THU 7.5 NMINAL TNS, 3 PH) MDELS 018-060 (1 PH) 036-048 (3 PH) 036-21002-001 EV. B (0600)
More informationH4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER
ENVIRONMENTALLY SOUND REFRIGERANT EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Copeland
More informationCommand Center. Model Number Helicopter, Motorcycle, equipment packs and figures sold separately.
Command Center Model Number 72955 Helicopter, Motorcycle, equipment packs and figures sold separately. Please keep these instructions for future reference. Adult assembly is required. Requires three, size
More informationHEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]
FORM NO. P11-729 REV. 6 Supersedes Form No. P11-729 Rev. 5 HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES Nominal Sizes 1 1 /2 to 5 Tons [5.28 to 17.58 kw] The Rheem RPKA- Heat Pump Outdoor units can provide
More information30A SMART ENERGY MANAGEMENT SYSTEM TM
30 Amp EMS Display Panel P/N 00-00903-030 (Black) 30 Amp EMS Distribution Panel P/N 00-0091-000 CAUTION The 30A SMART EMS is a centralized power switching, fusing, and distribution center. Power from the
More informationFLXA21 Quick Start-up Manual
FLXA21 Quick Start-up Manual This Tech Note is designed to assist with the installation of the FLXA21. This document should be used in conjunction with the User s Manual of the FLXA21. 1. Wiring and Installation
More informationInstallation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.
Installation Guide DigiTract Two Stage Heat/Cool Comfort Control System Part #DTMAN Rev. February 008 Zoning Systems That s all we do. TABLE OF CONTENTS...Page INTRODUCTION... SYSTEM DESCRIPTION... COMPONENT
More informationProduct Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL
SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated equipment only. US Patents: Carrierr U.S.
More informationASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual
Pull Side Applications with Slide Track (7210, 7250) (see page 7 for template) 7200 Series Multi-Point Hold Open Installation and Instruction Manual 3 1 Push Side Applications with Double Lever Arms (7220,
More informationTractor Interface Module Installation Instructions. Switch Input (TIM-SI)
Tractor Interface Module Installation Instructions Switch Input (TIM-SI) 821-7002 Installation Instructions Tractor Interface Module Switch Input (TIM-SI) 821-7002 Getting Started... 1 Installing the TIM...
More informationRadio-Control Raceway
Fisher-Price Instructions Radio-Control Raceway Please keep these instructions for future reference. Adult assembly is required. Requires four size AA alkaline batteries in each car (not included). Requires
More informationSAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4
Table of Contents SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4 USING THE CODE READER CODE RETRIEVAL PROCEDURE... 7 VIEWING ABS DTCs...
More informationG7100S, 3-Way, Mixing Flanged Globe Valve
pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Suitable ctuators Non-Spring
More informationPM Series Power Module Power Supply/Battery Charger
PM Series Power Module Power Supply/Battery harger INSTALLATION / OPERATION MANUAL MODELS: PM-24-80, PM-48-50 Table Of ontents Topic Page QUIK REFERENE ONTENTS 2 I) OVERVIEW 3 II) A POWER QUALITY AND EMI