IM RPM Series. Rotary Meter. (Standard, ETC & CMTC) Installation, Operation, Maintenance. Line Mounted Models. 3.5M Standard Meter Shown

Size: px
Start display at page:

Download "IM RPM Series. Rotary Meter. (Standard, ETC & CMTC) Installation, Operation, Maintenance. Line Mounted Models. 3.5M Standard Meter Shown"

Transcription

1 IM TM RPM Series Rotary Meter (Standard, ETC & CMTC) TM Installation, Operation, Maintenance Line Mounted Models 3.5M Standard Meter Shown

2 AMERICAN METER 5 YEAR LIMITED WARRANTY RPM SERIES ROTARY METERS American Meter Co. Industrial Products Division (hereafter referred to as the Company) offers to supply Rotary Meters of exceptional design, material and workmanship. The company will correct any defect(s) in material or workmanship occurring during the period of one year after shipment (the Warranty Start Date ) providing the Purchaser has given the company immediate written notice of the defects. In addition an extended 5-year warranty to the original owner in a permanent meter installation is offered against structural failure and for other identified components (list furnished by writing our general offices) from the Warranty Start Date under normal use, operation and maintenance. The Company obligation under this warranty is limited at its option to repayment of the purchase price, repair, replacement, or furnishing a similar part upon inspection and confirmation of the defective condition. THERE ARE NO OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED AND ANY OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. No allowance or reimbursements will be made for repairs or alterations unless made with the written consent first obtained from the Company. In no event shall the Company liability to the customer, regardless of the reason, exceed the purchase price of the product. No claim of breach of warranty shall constitute a cause for cancellation of this contract or any part thereof. The Company reserves the right to exclude from this warranty damages caused by any of the following: Overpressurization beyond the badge rating of the meter. Snap acting loads. Work done, apparatus furnished, repairs or alterations made by others. Auxiliary equipment supplied not manufactured by the Company Less than specification performance caused by improper gas stream filtration, and improper installation. Collision, fire, theft, lightning, vandalism, explosion, natural disaster, or objects striking the meter. Misuse of the meter for applications and processes not originally designed for or recommended by the company. Corrosion due to improper environmental conditions, chemical treatments, after-market products and chemical reactions. Sealants applied as excessive or not recommended by the company. Laws of the Commonwealth of Pennsylvania are applicable to this warranty. CAUTION As a knowledgeable user of American Meter s products, we are sure that you are aware that parts in the Company s meters and regulators contain or are coated with heavy metals such as cadmium, zinc, lead and chromium. Obviously, therefore, repair or refurbishment of this equipment should take into account the presence of these materials and should comply with all state and federal requirements concerning worker protection, proper disposal and safety, including protection against exposure to dust and fumes.

3 TABLE OF CONTENTS Chapter 1 Introduction General Description Features Standards Principles of Operation Sizing/Accuracy Chapter 2 Installation Basic Requirements Uncrating the Meter Mounting and Leveling Check & Start-up Operation Lubrication Differential Testing Chapter 3 Optional Temperature Compensator Why Temperature Correction? Standard General Description CMTC General Description Vertical & Horizontal Installation CMTC Operation Reverse Flow Conversion Proving Operations Meter Shop Test Procedures Chapter 4 Inspection/Routine Maintenance Maintenance Troubleshooting Chapter 5 Optional Instrument Drive Instrument Drive Kit Optional Mercury ID Chapter 6 Appendix Maintenance Record Form Differential Rate Data Test Form

4 ! WARNING - EXPLOSION HAZARD! Read carefully and follow all instructions shipped with this meter. The incorrect installation of this equipment could result in escaping gas, and pose a potential explosion hazard.

5 Introduction Meters utilized in the natural gas industry are divided into two general categories: inferential or positive displacement. The inferential category includes turbine and orifice meters. Turbines are also referred to as velocity meters as they measure the gas velocity flowing through a pipeline. Meters in the positive displacement category are the diaphragm and rotary types. Rotary gas meters have been utilized in the industrial and commercial markets for decades and were produced in various designs. For today s gas utility, the rotary s primary application is to fill the flow gap between the diaphragm meter and the turbine meter. Like the diaphragm meter, the rotary meter measures gas with compartments that alternately fill and empty. In addition to non-residential applications, many production fields or well head users utilize the rotary meter to provide accurate well head measurement at various pressures. When properly sized, installed, and maintained, the rotary meter provides accurate and dependable measurement from low to high pressure applications for many years. GENERAL DESCRIPTION The rotary meter is suitable for measuring most types of clean common gases. It is NOT intended for handling liquids, acetylene or sewage gas, and its operation/accuracy can be affected by excessive deposits of dirt or other foreign materials carried in the gas stream. The basic type of rotary meter utilizes two opposite rotating two-lobe impellers. Internally there are no contacting parts in the measurement chamber. As adjusted from the factory, there is usually no wear as long as the meter is kept clean, leveled, and the bearings are properly lubricated. FEATURES American Meter s RPM Series Rotary Meters are available in ten (cfh) 175 psig (12 bar) MAOP: 8.0C 3.5M (G65) 9.0C (G16) 5.5M (G100) 1.1C 7M 1.5M (G25) 11M 2M (G40) 16M (G250) 1-1

6 Introduction MINI-MAX mi Electronic Gas Volume Corrector CFx100 NON - COMPENSATED VOLUME READING X 100 = CU FT 3 The meters are available in three configurations: Standard Temperature Compensated (optional) Electronic & Mechanical. See page 3-1 and 3-2 for details. Instrument Drive (optional) All rotary meters are equipped with an uncorrected mechanical counter. The output end with uncorrected mechanical counter rotates 90 o without interrupting pressurized chamber to facilitate vertical or horizontal mounting. All models/sizes can be easily converted to instrument drive. The universal mounting plate rotates 360 o in 45 o increments. Performance characteristics: Pressure rating: 175 psig (12 bar) Optional: 200psig (14 bar) or 285 psig (20 bar) Proof accuracy: +1% (U.S. and Canada) + 2% (Int l) at low flow rates. Rangeability (see Rangeability Chart). ref.: ANSI B109.3 Rotary Gas Meters; Part III; page 10, Accuracy. Operating temperature: -40 o to 140 o F (-40 o to 60 o C) Temperature compensation display: -40 o to 140 o F (-40 o to 60 o C) Output of 8.0C to 11M is 10 cubic feet per pulse or.1 cubic meter per pulse. 7M & 16M is 1 cubic meter. 16M is 100 cubic feet per pulse. Rangeability Chart Note: The numbers listed represent fully assembled production meters using standard proving practice. Cubic Ft/Hr Rangeability Model Start Rate +1% +2% 8.0C/9.0 C <3.0 >30:1 >60:1 1.1C/1.5 M <3.0 >40:1 >75:1 2M/3.5 M <4.0 >75:1 >140:1 5.5 M <4.4 >120:1 >210:1 7 M <5.5 >70:1 >115:1 11M <5.5 >120:1 >225:1 16M <7.0 >100:1 >150:1 Fig. 1-1 Compensating Module An optional Electronic Temperature Compensator is also provided. See page 3-1 for details. 1-2

7 Introduction STANDARDS The American Meter s RPM Series Rotary Meter meets the following codes and standards: ASME Boiler & Pressure Vessel Code; Section VIII ANSI B16.5 Flanged Pipe & Fittings ANSI B31.8 Gas Piping ANSI B109.3 Rotary Gas Meters (92) 49 CFR 192 Min. Federal Safety Standards National Safe Transit Association (NSTA-1A-Packaging) Underwriter s Laboratory (UL) Measurement Canada FLOW Position 1 PRINCIPLES OF OPERATION The opposite rotating figure 8 impellers of a rotary meter operate within a rigid casing that has inlet and outlet gas connections on opposite sides. The impellers rotate as a result of the pressure drop across the meter as downstream gas is consumed. The rotating impellers separate the flowing gas stream into small segments before the gas enters the downstream piping. These small segments are counted using a gear train which drives the meter index or correcting instrument. See Fig Position 1 Position 2 As the bottom impeller rotates in a counterclockwise direction toward the horizontal position, gas enters the space between the impeller and the cylinder. At the horizontal position, a definite volume of gas is contained in the bottom compartment. FLOW FLOW Position 2 Position 3 Position 3 As the impeller continues to turn, the volume of gas is then discharged. FLOW Position 4 Concurrently, the top impeller rotating in the opposite direction has closed to its horizontal position, confining another known and equal volume of gas. This process is repeated four times for each complete revolution of the impeller shafts. Position 4 Fig. 1-2 Rotation of Impeller Shaft 1-3

8 Introduction SIZING/ACCURACY There are four considerations to take into account when selecting and sizing a meter: 1. Inlet pressure 2. Required flow 3. Type of customer 4. Required pressure Additionally, when selecting a rotary meter for a specific installation, the normal minimum and maximum allowable operating pressure (MAOP) should always be considered. Industry standards recommend sizing rotary meters for 60% of the rated capacity and not lower than 10% of capacity. Because of the no contacting parts design, some gas can seep through the meter creating an error at low meter speeds. AMERICAN METER CO. recommends that the meter be sized so it will NOT OPERATE below 10% of its rated capacity for long periods of time. Low flow rate error is corrected each time the rotary meter operates at 10% or more of its rated capacity. Above the 10% flow rate, the meter s accuracy is slightly greater than 100%, and this compensates for possible error at low flow or pilot load flow rates. EXAMPLE: The following example depicts an average day in accuracy measurement from a rotary meter: A 5.5M rotary meter measuring natural gas consumption at a bakery that operates 16 hours a day: Gas Consumption Meter Accuracy 16 hrs x 4000 CFH = x 100.5% = hrs x 300 CFH (low flow) = 2400 x 98.0% = hrs = vs (actual) (registered) Average Daily Accuracy = 100.4% 1-4

9 Installation BASIC REQUIREMENTS When installing a rotary meter, it can be easy to overlook details that may hinder meter performance and maintenance. Usual emphasis is put on a clean gas flow through the meter by use of filtration and proper inlet and outlet piping. There are some DO'S AND DON TS that should always be considered when designing a rotary meter set. Refrain from using excessive amounts of pipe dope on inlet piping to the rotary meter. Chunks of pipe dope can break loose from screwed fittings and fall onto and in-between impeller lobes, rendering the meter immediately inoperative. Check for excess dirt, scale and weld splatters in the pipeline. Install an in-line pipe screen filter upstream from the meter to keep debris (i.e., stones, tap shavings, scale, and weld beads) from entering and causing damage to the meter. The use of an AMCO 80 mesh strainer is strongly recommended. See the parts list in the back of this document (Page 5.6) for ordering information. The elimination of smaller contaminants (i.e., grit) can be achieved with an AMCO Kleanline TM micron filter. If selecting full-port valves for the inlet and outlet piping, always use ball valves that require no, or minimal lubrication to achieve tight shut-off. Excessively greased plug valves will degrade rotary meter performance due to lubricant seeping into the meter. AMCO recommends if possible, installing a straight run of pipe without restrictions (i.e., valves, regulators, etc.) for a distance of six pipe diameters on either side of the meter (Fig. 2-1). This optimum set design will prevent a reduction in meter accuracy resulting from a turbulent gas stream. 2-1

10 Installation Fig. 2-1 Typical Installation (not to scale) Bypass piping can effectively reduce time spent on differential testing and maintenance. If a combined measurement and regulation set is installed, meter testing and regulation inspection can all be completed at the same time with minimum disruption of service. Bypass valves should have a tamper proof lock or seal to prevent theft of gas. Adequate service (working) clearance around the meter should be maintained to allow easy access for reading the meter indexes. For temperature compensated meters, a 6" clearance space for the temperature probe is necessary to permit the removal of the TC counter module if necessary. Clearances are also required for differential testing access, inspection and normal lubrication maintenance. The meter should never be installed so that it is lower than the discharge pipe runs. This would allow the meter to become a sump for condensate and other foreign material. 2-2

11 Installation UNCRATING THE METER Unpacking instructions are also included in the shipping container. American RPM Series meters utilize packaging that meet ISTA (International Safe Transit Association) test specifications. Even with the packaging s rugged construction, the meter should be handled with care in transport and storage to protect its factory certified accuracy. NOTE: If outer package shows evidence of damage through mishandling in transit, NOTIFY the shipper and immediately perform a careful inspection of the meter. FILE a claim with the shipper if damage is indicated and also notify your local AMCO sales office. See Appendix for listing. NOTE: All packaging has size of meter inside, and an arrow depicting UP. 1. Carefully open the shipping container at the top seam. When cutting the top seam be careful not to cut too deeply into the area where the meter and accessories are lodged. 2. Open up the two top flaps and bend outward. 3. Remove the lubrication kit, instruction manual, and magnetic wand if the meter is equipped with the temperature compensator. The box will also contain the certificate of accuracy documentation. This should be filed for further reference. 4. Remove the center and end cardboard dividers. 5. Carefully grasp the meter by the center of the body and lift upward. See Figure 2-2. CAUTION: If the meter is equipped with a temperature compensator module, DO NOT LIFT THE METER BY THE COMPENSATOR MODULE ON THE END. 6. Always check new meters for free rotation after removal from the shipping container. This procedure is described in the following section, Check and Start-up. 7. If the meter is not to be installed or tested immediately, return the meter to its shipping container and place horizontally, red arrow pointing UP, in a dry, protected area. DO NOT put oil in the meter until it is to be installed. Fig. 2-2 Unpacking the Meter 2-3

12 NON - COMPENSATED VOLUME READING X 100 = CU FT 3 I Installation MOUNTING AND LEVELING Proper support is necessary for any gas meter installation. If properly designed it provides stability and a sound base to eliminate vibration to the meter. If the ground surface is unstable, industry standards recommend an 8"x 8"x16" solid block be used to set the inlet and outlet risers. Riser legs should be at 90 o angles from the set. A rotary meter can be installed horizontally facilitating the change out of an old meter set; however the preferred installation is top inlet in a vertical pipeline. Vertical mounting allows contaminants to be expelled more easily via gravity from the meter. A rotary meter should be installed close to 100% level at all times. Deviation from level should not be more than +1/16" per foot in all directional planes. If the meter is not set level, it is possible to overfill or underfill the oil reservoirs while the oil sight glasses indicate the proper level. Overfilling with oil can cause the meter to read incorrectly due to increased drag on the gears and possible bleeding of oil into the measurement chamber. Under filling meters that are not level can lead to excessive bearing wear and will be evident on differential testing Fig. 2-3 Optional 1 1 / 2 " NPT Flange (9.0 C & 1.5M Only) P/N 52996K001 ADD O L H E R E CHECK & START-UP OPERATION The following steps should be utilized to insure a trouble-free start-up of the AMCO RPM Series Rotary Meters. 1. Remove the meter from the shipping carton and inspect for damage that may have occurred during transit. See previous section, Uncrating the Meter procedure. 2. Set the meter on the bottom of the over-turned shipping carton and remove the protective caps from both flange openings. CAUTION: Do not let dirt, debris, etc., enter flange openings! 3. Lightly blow into the inlet of the meter. This slight air pressure should cause the impellers to rotate freely and come to a stop slowly. If the impellers do not turn, this indicates a possible foreign object within the measurement cavity and the meter should be returned to the repair shop or manufacturer. 4. Verify that the mating flanges or optional flanges (refer to Figure 2-3), for the meter plus the correct distance (FL) are as close to level; within 1/16" per foot in all directions. 2-4

13 Installation NOTE: (FL) = Meter + (2) gaskets + 1/16" clearance. The correct bolt sizes for the RPM series meters is 5/8-11 x 1-3/4" Hex Head. All bolts should be installed with flat washers. Tighten bolts evenly. Do not over torque (max. 80 ft-lbs.) 5. Remove the center pipe plug on the rear gear cover and verify the impellers still turn freely. 6. Fill unit with correct amount of oil. See LUBRICATION. 7. Turn the gas supply on SLOWLY at approximately 1 second per 10 psig maximum. Turning the gas on quickly could potentially overspeed and possibly damage the meter. CAUTION: Should the installation be subject to extreme INSTANT ON loads, the meter should be protected from overspeeding by a restricting flow orifice plate. 8. Leak test the meter and all connections. LUBRICATION Gears and bearings in the rotary meter are lubricated by the Dip and Splash method. Sight plugs are located on both ends of the meter. Any sight plug or pipe plug on the end covers can be used for access for filling with oil, depending on the meter mounting. See Fig CAUTION: Oil sumps at each end of the meter are independent and each must be filled with an EXACT amount of oil as shown on pg Fig. 2-4 Location of sight plugs 2-5

14 Installation To fill unit with oil: 1. Remove the two top oil sight or pipe plugs on the timing gear and counter covers. Fill the unit with the EXACT amount of approved oil (AMCO recommends using SHELL Tellus T oil 15 or TEXACO Aircraft Hydraulic #15). Reference the required EXACT capacities from the chart shown below. 2. Reinstall the two oil sight or pipe plugs. For quantities refer to the capacity chart (below) for vertical or horizontal mounting by meter size. Fig. 2-5 Oil Level CAUTION: Oil should be visible within 1/16" of the center of the oil level sight plug (Fig. 2-5). After filling, check to verify correct level. Overfilling may result in poor meter performance and underfilling can lead to excessive bearing wear. RPM Oil Level Capacity Chart (EXACT Amounts) Vertical Horizontal Meter Drive Gear Total Drive Gear Total Size (oz.) (oz.) (oz.) (oz.) (oz.) (oz.) RPM 9.0C RPM 1.5M RPM 3.5M RPM 5.5M RPM 7M RPM 11M RPM 16M Oz. (CC) 0.9 (26) 1.6 (47) 2.5 (73) 2.7 (80) 2.9 (85) 3.8 (111) 5.6 (165) 5.8 (170) 6.5 (191) 6.6 (195) 6.8 (200) 8.5 (250) Oil Capacity Metric Conversion Note: An 8 oz. bottle of oil is provided with the meter. AMCO recommends the use of SHELL Tellus T oil 15 or TEXACO Aircraft Hydraulic #15 lubricating oil. WARNING: The filling should be NOT done while the meter is in service. The end covers of the sight plugs are pressurized. If the meter is in service and filling is necessary, bleed off the line pressure before removing sight plug. The use of the optional PETE S PLUG allows oil to be added under pressure during normal maintenance. Oil changes should be made when oil appears dirty (black) or diluted. Oil should be changed one year after installation and every five years thereafter unless differential testing indicates teardown for cleaning. To change the oil: 1. De-pressurize the meter. 2. Remove the bottom pipe plug. 3. Fill from the top pipe plug or sight glass opening using the EXACT amounts in the capacity chart.

15 I Installation DIFFERENTIAL TESTING: Meter accuracy, regardless of the manufacturer, is unlikely to improve with use. Therefore it is important to develop performance standards on the meter at installation so those standards can be monitored at a future point in time. Differential testing is used to determine changes in the meter after installation. The test is performed using a differential pressure manometer under actual conditions of gas flow rate, line pressure and specific gravity. In lieu of a transfer prover, differential testing gives a good indication of the operational condition of the meter. It does not indicate meter accuracy. AMERICAN METER CO. furnishes a test report with each rotary meter enclosed in the shipping carton. The test report indicates percent rated capacity, accuracy, proof and differential pressure for various flow rates of the meter. This test report also is kept on file by AMCO for the life of the meter. The Appendix of this manual includes a blank chart. The installer can record a performance curve on initial start-up of the meter. The installer should plot a point on the chart for each differential at each level of capacity tested. Three points are required within the 25% to 100% range to establish a representative curve at installation, after 5/10 years and after solvent flushing. Refer to Fig Differential Pressure Testing Taps ADD O L H E R E Installation Year 5 Year 10 Year 10 (after flushing) Differential Inches W.C. Flow Rate at Inlet Conditions Percent of Maximum Flow Rate Fig. 2-6 Plot of Differential Testing Field testing on gas below 15 psig can be compared directly with AMCO factory test results on air as indicated on the furnished accuracy test report. It is always important to test the meter under the actual conditions of gas line pressure and 2-7

16 Installation DIFFERENTIAL TESTING: CON T. specific gravity that will exist in service. This is particularly important when line pressure is above 15 psig so that a direct comparison with later tests can be made. Although as previously stated, accuracy cannot be directly determined by differential test. Test results have indicated that an increase of up to 50% in differential pressure can be tolerated without affecting meter accuracy at flow rates of 25% and above. There are three things that can potentially affect a meter s accuracy which would also affect the differential test results: 1. Change in the Static Displacement 2. Enlargement of clearances between moving parts 3. Internal resistance increase Change in the Static Displacement The U.S. National Bureau Of Standards Paper 1741, TEST- ING LARGE CAPACITY GAS METERS, pg. 187, states: The Static Displacement of a Rotary gas meter appears to be almost unaffected by deposits, even those resulting from unpurified gas. Hence, having once been determined, it will seldom be necessary to redetermine. Enlargement of clearances between moving parts There is NO wearing of internal parts because the moving parts have NO direct contact with other surfaces. Hence clearances DO NOT change between the body and the impellers. Internal resistance increase Internal resistance is the most critical factor in the effects on meter accuracy because any significant increase in resistance will increase the pressure drop across the meter. The most common causes of an increase in internal resistance are: dirt, pipe dope, thread shavings between impellers, worn bearings bending torque on the body, and heavyweight or excessive amounts of oil. If the differential test at the time of installation is found to be 50% greater than what was indicated on the AMCO factory test results, the meter should be taken out of service and 2-8

17 Installation DIFFERENTIAL TESTING: CON T. returned to your local AMCO sales representative for replacement under the terms of the WARRANTY described previously. If the differential test during normal maintenance and after prolonged service is found to be more than 50%, the meter should be taken out of service for cleaning. A simple flushing with mineral spirits, kerosene or your company approved solvent should easily remove the foreign materials within, and bring the meter back into acceptable specification. If the flushing operation fails to bring the meter into specification, the unit should be returned to your approved meter repair shop for tear down and bearing replacement. AMCO recommends draining the oil from the meter end caps after blowdown to atmosphere, to prevent oil from splashing onto the impellers during transport. While there is no nationally established time period for testing, some states have formally adopted differential rate test periods. Aside from these states, a five year test interval is generally considered acceptable. Recommended frequency of differential testing: 1. At the time of installation 2. Twelve months after initial installation 3. Every 5 years thereafter NOTE: Always consult your company policy or state/country commissions for specific time intervals on differential rate test periods. See sample Differential Test Chart on page See Maximum Allowable Differential Pressure Charts at psig. by meter size on pages 2-10, 2-11 &

18 Installation Sample Differential Rate Test Data Meter Model 5.5M Mfg. Serial No Utility Serial No. Location Date Installed 1/1/97 Register Reading Line Gas Sp. Volume Run Rate Diff. Pressure Press. Temp Grav. Measured TIme CFH Ins. W.C. % Chg. Date Initial Test - New Meter 2 psig 60 o F.6 10 cf 29s /1/97 2 psig 60 o F.6 10 cf 14s /1/97 2 psig 60 o F.6 10 cf 8s /1/97 Periodic Check Tests 2 psig 60 o F.6 10 cf 29s /17/00 2 psig 60 o F.6 10 cf 14s /17/00 2 psig 60 o F.6 10 cf 8s /17/00 2 psig 60 o F.6 10 cf 29s /25/05 2 psig 60 o F.6 10 cf 14s /25/05 2 psig 60 o F.6 10 cf 8s /25/05 2 psig 60 o F.6 10 cf 29s /26/05 2 psig 60 o F.6 10 cf 14s /26/05 2 psig 60 o F.6 10 cf 8s /26/05 AMCO 8.0C/9.0C Rotary Meter - Maximum Allowable Differential Pressure Percent Flowrate ATM Volume Run Rate Diff. Pressure Capacity (CFH) ATM 15 psig 30 psig 45 psig 60 psig 90 psig

19 Installation AMCO 11C/1.5M Rotary Meter - Maximum Allowable Differential Pressure Percent Flowrate ATM Volume Run Rate Diff. Pressure Capacity (CFH) ATM 15 psig 30psig 45 psig 60 psig 90 psig AMCO 2.0M/3.5M Rotary Meter - Maximum Allowable Differential Pressure Percent Flowrate ATM Volume Run Rate Diff. Pressure Capacity (CFH) ATM 15 psig 30psig 45 psig 60 psig 90 psig

20 Installation AMCO 5.5M Rotary Meter - Maximum Allowable Differential Pressure Percent Flowrate ATM Volume Run Rate Diff. Pressure Capacity (CFH) ATM 15 psig 30psig 45 psig 60 psig 90 psig M Differential Pressures % Atmospheric 15 psi 30 psi 45 psi 60 psi 90 psi in wc 0.05 in wc 0.02 in wc 0.06 in wc 0.07 in wc 0.06 in wc in wc 0.08 in wc 0.05 in wc 0.10 in wc 0.13 in wc 0.11 in wc in wc 0.11 in wc 0.14 in wc 0.23 in wc 0.29 in wc 0.36 in wc in wc 0.15 in wc 0.23 in wc 0.30 in wc 0.39 in wc 0.50 in wc in wc 0.27 in wc 0.40 in wc 0.50 in wc 0.70 in wc 0.96 in wc in wc 0.48 in wc 0.66 in wc 0.85 in wc 1.06 in wc 1.49 in wc in wc 0.69 in wc 1.20 in wc 1.30 in wc 1.60 in wc 1.90 in wc in wc 1.08 in wc 1.51 in wc 1.94 in wc 2.40 in wc 2.86 in wc in wc 1.20 in wc 1.70 in wc 2.27 in wc 2.85 in wc 3.36 in wc in wc 1.24 in wc 1.93 in wc 2.57 in wc 3.32 in wc 3.91 in wc in wc 1.42 in wc 2.10 in wc 2.84 in wc 3.64 in wc 4.30 in wc in wc 1.58 in wc 2.32 in wc 3.19 in wc 4.16 in wc 4.91 in wc in wc 1.78 in wc 2.48 in wc 3.70 in wc 4.51 in wc 5.30 in wc 2-12

21 Installation 11.0M Differential Pressures % Atmospheric 15 psi 30 psi 45 psi 60 psi 90 psi in wc 0.04 in wc 0.06 in wc 0.06 in wc 0.05 in wc 0.09 in wc in wc 0.10 in wc 0.08 in wc 0.10 in wc 0.13 in wc 0.17 in wc in wc 0.12 in wc 0.23 in wc 0.29 in wc 0.30 in wc 0.48 in wc in wc 0.25 in wc 0.39 in wc 0.50 in wc 0.60 in wc 0.94 in wc in wc 0.34 in wc 0.51 in wc 0.76 in wc 0.93 in wc 1.29 in wc in wc 0.63 in wc 0.87 in wc 1.20 in wc 1.47 in wc 1.74 in wc in wc 1.04 in wc 1.52 in wc 2.03 in wc 2.40 in wc 2.86 in wc in wc 1.39 in wc 2.09 in wc 2.73 in wc 3.55 in wc 4.26 in wc in wc 1.48 in wc 2.15 in wc 3.02 in wc 3.90 in wc 4.66 in wc in wc 1.75 in wc 2.65 in wc 3.13 in wc 4.25 in wc 4.93 in wc in wc 1.96 in wc 2.97 in wc 4.05 in wc 4.89 in wc 5.76 in wc in wc 2.19 in wc 3.40 in wc 4.65 in wc 5.63 in wc 6.60 in wc in wc 2.15 in wc 4.15 in wc 5.50 in wc 6.61 in wc 7.73 in wc 16.0M Differential Pressures % Atmospheric 15 psi 30 psi 45 psi 60 psi 90 psi in wc 0.28 in wc 0.28 in wc 0.28 in wc 0.28 in wc 0.43 in wc in wc 0.83 in wc 1.11 in wc 1.11 in wc 1.16 in wc 1.16 in wc in wc 0.83 in wc 1.27 in wc 1.44 in wc 1.50 in wc 1.72 in wc in wc 0.91 in wc 1.33 in wc 2.22 in wc 2.36 in wc 3.88 in wc in wc 1.11 in wc 1.39 in wc 2.49 in wc 3.05 in wc 4.71 in wc in wc 1.25 in wc 1.66 in wc 3.32 in wc 4.71 in wc 6.37 in wc in wc 1.66 in wc 1.91 in wc 4.43 in wc 5.13 in wc 6.82 in wc in wc 1.86 in wc 2.16 in wc 4.57 in wc 5.40 in wc 7.09 in wc* in wc 1.94 in wc 2.33 in wc 4.71 in wc 5.82 in wc 7.79 in wc* in wc 2.22 in wc 2.49 in wc 4.99 in wc 6.10 in wc* 8.17 in wc* in wc 2.49 in wc 2.77 in wc 5.35 in wc 6.93 in wc* 9.00 in wc* in wc 2.77 in wc 4.16 in wc 6.10 in wc 8.04 in wc* 9.59 in wc* in wc 3.60 in wc 5.13 in wc 7.20 in wc 8.59 in wc* in wc* * Values are calculated from the average change in pressure at specified percent flow rate. 2-13

22 2-14 Installation

23 Standard, ETC, CMTC General Description WHY TEMPERATURE CORRECTION? All commercially used non-temperature compensated natural gas meters are designed to meter gas at 60 o F (15.6 o C)(base temperature). At 40 o F (4.4 o C), that meter actually passes 1.04 cubic feet for every one cubic foot registered. When this happens, the customer receives 4% more gas than they are billed for. If we use the example of the day in the life of a 5.5M Rotary Meter at the bakery as depicted on page1-4 of this manual; lack of temperature compensated metering can be costly in lost and unaccounted for gas delivery. EXAMPLE: The average temperature of metered gas in February in New England, is 40 o F (4.4 o C) which is a 4% change in volume from the 60 o F base temperature (+ 5 o F = 1% change in volume). In the 28 days of February the non-compensated rotary meter registered 1,866,816 ft 3 of gas; however, because the flowing gas temperature was 40 o F (4.4 o C) the bakery could have received 1,941,489 ft 3 ; a loss to the utility of 74,673 ft 3 of gas for the month unless corrected for at the time of billing. MINI-MAX mi Electronic Gas Volume Corrector CFx100 At $.70 per 100 ft. 3, the financial loss to the utility for one month gas delivery to the bakery if uncorrected was $522.71, more than the original cost of the optional add on Temperature Compensator module to the meter. Correction at billing time can also be inaccurate as flowing gas temperatures can fluctuate by the hour during normal gas delivery. Temperature Compensation of the meter is by far the $mart choice. GENERAL DESCRIPTION Electronic Temperature Correction (ETC) Module Mercury Instruments a name synonymous with quality and reliability in the natural gas industry now offers its affordable Mini-Max T corrector for the RPM Series American Meter rotary meter. Obtain maximum performance and value with compact electronic precision and reliability. Use the Mini-Max T to reduce your costs of gas measurement and enhance the efficiency of your rotary meter operations. NON - COMPENSATED VOLUME READING X 100 = CU FT 3 Fig. 3-1 RPM Temperature Compensator The optional Mercury electronic temperature corrector and mounting can rotate at 90 0 increments to accommodate readings at any meter position. For additional Mercury products and features, see AMCO bulletins SB5500 or DS

24 Standard, ETC, CMTC General Description WARNING EXPLOSION HAZARD DO NOT OIL THIS INDEX READING X 100 CU. FT. TEMPERATURE COMPENSATED VOLUME BASE TEMP. 60 F (15.6 o C) NON - COMPENSATED VOLUME = READING X 100 = CU FT FEATURES & PERFORMANCE The Mini-Max T mounts directly to the RPM Series Rotary Meter (field or factory). It features a live LCD display of input gas temperature from to F (-40 0 to C). It offers membrane push-button and user-configurable alphanumeric LCD for display of : test, uncorrected volume, corrected volume, fixed-set pressure, live temperature, battery voltage, live flow, and electronic uncorrected backup. In addition, the Mini-Max T features programmable call-in (scheduled and alarms), field programmable firmware through serial port (flash memory), two form-a volume pulse outputs and one form A alarm pulse outputs, an audit trail memory of 40 days of daily-corrected volume, uncorrected volume, average pressure and average temperature. It also has low power requirements 4 years+ on 4 D-cell alkaline batteries. An optional 4-20mA output and messenger modem is also available. Read carefully and follow all instructions shipped with this meter. The incorrect installation of this equipment could result in escaping gas, and pose a potential explosion hazard. Fig. 3-3 Standard CMTC Compensator DO NOT OIL THIS INDEX READING X 100 = CU. FT. TEMPERATURE COMPENSATED VOLUME BASE TEMP. 60 F (15.6 o C) NON - COMPENSATED VOLUME READING X 100 = CU FT 3 CMTC GENERAL DESCRIPTION The new CMTC* RPM Series gas meter provides flowing gas-volume registration continuously and mechanically corrected to the standard base temperature of 60 degrees F. Continuous compensation output allows for greater accuracy, as the adjustment input is a linear function proportional to the temperature changes of the flowing gas. Quicker reaction time to temperature changes occur with the CMTC liquid filled temperature transducer directly in the gas stream when compared to other bi-metal sensor designs shielded within a thermowell. The new American Meter CMTC Accessory unit is an addition to the current RPM accessory line. The CMTC accessory is only intended for use on the RPM Series of rotary meters from American Meter and is also available in metric sizes. The CMTC has been designed to provide many years of maintenance-free service. 3-2 Fig. 3-4 CMTC w/pulse Output - Military Connector Shown OPTIONS The Continuous Mechanical Temperature Compensator is available in three configurations: Standard CMTC on meter (Fig. 3-3).

25 Standard, ETC, CMTC General Description CMTC with pulse output mounting capability (Fig. 3-4). CMTC with instrument drive accessory. This option would allow the mounting of a pressure compensating index providing full mechanical temperature and pressure compensation or the addition of other pulse output devices. (Fig. 3-5). WARNING: The American Meter CMTC is designed to drive a maximum of 10 in-oz. of torque. Devices that require more torque may cause premature failure of register. WARNING: DO NOT oil this index. NOTE/CAUTION: Each CMTC accessory is identical on all size RPM Series Rotary meters with the exception of the (4) colored set gears. These colored set gears are unique to each size meter due to the required capacities (SCFH) and accuracy requirements of 1%. Each CMTC accessory is marked with the size of the meter on which it is to be mounted. DO NOT interchange a CMTC accessory to another meter without making sure the meters are of the same size. For example: 3.5M to 3.5M is permitted. However, 3.5M to 7M is NOT permitted. STANDARD & CMTC ODOMETER FACE PLATE(S) BASIC OPERATION The Standard index counter only displays uncorrected volume (Fig.3-6). The CMTC index counters display both compensated (corrected) volume in white numbers (top set of counters) and non-compensated (uncorrected volume) in shaded blue numbers (lower set of counters) (Fig. 3-7). The CMTC index and Standard index is available in English and metric versions. The CMTC as referenced above implements a unique method of shielding specific odometer digits from the meter reader. The CMTC uses translucent shields which tint, but do not completely shield, the desired digit(s). The CMTC has two odometers. The top odometer represents temperature compensated volume and is marked as such in red text to clearly distinguish it from the non-compensated odometer. Again the top or compensated odometer has one digit furthest to the right tinted to reduce its readability, with the remaining six digits marked in red text as reading in hundreds of cubic feet. The bottom odometer represents non-compensated volume and is marked in black text. Every digit on the bottom, or non-compensated X 100 Fig. 3-5 Standard with Instrument Mounting Drive Accessory (optional X10 or X100) Fig. 3-6 Standard Odometer Face Plate - English Shown READING X 100 = CU. FT. TEMPERATURE COMPENSATED VOLUME BASE TEMP. 60 F (15.6 o C) NON - COMPENSATED VOLUME READING X 100 = CU FT 3 DO NOT OIL THIS INDEX NON - COMPENSATED VOLUME READING X 100 = CU FT DO NOT OIL THIS INDEX NON - COMPENSATED VOLUME READING X 100 = CU. FT. DO NOT OIL THIS INDEX Fig. 3-7 CMTC Odometer Face Plate 3-3

26 Standard, ETC, CMTC General Description odometer, is tinted to reduce readability. The combination of tinting and clear marking makes it simple to read the correct volume reading. VERTICAL/HORIZONT TICAL/HORIZONTAL INSTALLA ALLATION All Standard and CMTC meters are capable of a vertical or horizontal installation. In both cases, the odometer face plate on the temperature compensator aligns with the meter badge on the body of the rotary meter. It is not possible to rotate the mechanical temperature compensator separate from the meter. Should your application require the meter to function in an opposite gas flow direction, you will need to specify this when placing your order or see instructions on page 3-5. Fig. 3-8 Wriggler Corrector Clearance Space Required Meter Fig. 3-9 Wriggler Clearance Fig Removing Retaining Ring Vertical position (vertical/downward flow of gas): Odometer face plate of the CMTC is facing the front of the meter, matching the meter badge serial number plate. The CMTC is positioned left with respect to the meter. Horizontal position (horizontal/left to right flow of gas): Odometer face plate of the CMTC is facing the top of the meter, matching the meter badge serial number plate. The CMTC is positioned left with respect to the meter. ADDITIONAL PULSE OUTPUT DEVICES For those applications requiring additional pulse output devices the CMTC provides a direct mechanical drive connection for such devices called a wriggler (Fig. 3-8) This wriggler is exposed for third party accessory connection such as a pulse output device through a circular opening in the end of the Lexan cover or at the top of the instrument drive mounting accessory. Proper spacing between the wriggler and accessories is necessary to ensure unit does not bind or break. Refer to figure 7 for proper clearances. When installing all devices, make sure the wrigglers are in line and mate properly. Continuous downward force on the meter wriggler will cause damage to meter register and premature failure. It should be noted that AMCO s CMTC is capable of driving devices requiring up to 10 in-oz. maximum of torque. Attaching devices requiring more torque for operation may cause premature failure of register. 3-4

27 Standard, ETC, CMTC General Description WRIGGLER ROTATION TION DIRECTION Illustration shown is 1:1 gear ratio. The factory default rotation direction of the wriggler is in a clockwise direction when looking down on the Instrument Drive from above. Should the installation of your pressure correcting or pulse output device require counter clockwise rotation of the wriggler, follow the procedure below. Before attaching the Instrument Drive, loosen the (2) socket head cap screws holding the angle bracket assembly to the inside of the Instrument Drive and remove from the Instrument Drive housing. Remove the retaining ring from the metal shaft (Fig.3-10). Slide the angle bracket to the right (Fig (1)) Next slide the shaft to the right (Fig (2)) being careful not to lose the nylon gear riding on shaft. Remove the nylon gear (Fig (3)). Flip gear horizontally and replace on shaft making sure the flat machined surface of the shaft mates with corresponding flat on inside of gear. Reattach retaining ring to the left of gear (Fig. 3-12). Next, slide the right side of angle bracket back to its original position ensuring its alignment with grooved surface just above the top gear (Fig. 3-12). Note: the shaft will follow in this step. Make sure it aligns properly with corresponding hole in left angle bracket. Finally, remount the angle bracket assembly into the Instrument Drive housing and install housing to CMTC. REVERSE FLOW CONVERSION All meter sizes come shipped from the factory with components which will allow for the conversion to reverse flow application. To convert a new meter from standard gas flow configuration to reverse flow configuration (upward or right-toleft)(fig. 3-17), follow all instructions below carefully. Should you have an older RPM Series rotary gas meter which needs to be converted for reverse flow application, contact American Meter Company for a Reverse Flow Kit (see page 3-7). WARNING: If meter is in service, it must be depressurized and oil drained from the drive side case cover. Step 1: Remove metric socket head cap screws from case cover and set aside. (Fig. 3-13) During cover removal, the rubber O-ring may fall loose. If so, simply reinstall it into the groove on the underside of the case cover. Step 2: Remove the 1/16" allen head screw and magnet holder. (Fig. 3-14) Step 3: Loosen set screw and remove spur gear with roll pin/ Fig Removing Retaining Ring Fig Repositioning of Gear 4 5 Fig Replacing Retaining Ring 3-5

28 Standard, ETC, CMTC General Description oil slinger (B) from bottom impeller shaft. (Fig. 3-14) Step 4: Loosen set screw and remove oil slinger hub (C) from top impeller shaft. (Fig. 3-14) Step 5: Install oil slinger (B) that had been removed from bottom shaft in step 3, on opposite impeller shaft (top), sliding it towards the meter body until the gears properly engage. (Fig. 3-15) Tighten set screw to 15 in-oz. Fig Removing Case Cover Step 6: Install oil slinger hub (C) that had been removed from top shaft in step 4, on opposite impeller shaft (bottom). Tighten set screw to 15 in-oz. (Fig. 3-15) 1/16" allen head screw A C Step 7: Reinstall magnet holder assembly with allen head screw using Loctite 222 to the centering shaft threads. Tighten flat head screw to 15 in-oz. (Fig. 3-16) Step 8: Rotate the meter impellers to assure that proper assembly has been made. Fig Removing Magnet Assembly (A), Oil Slinger (B) & Oil Slinger Hub (C) Fig Replacing Oil Slinger (B) to top shaft & Oil Slinger Hub (C) to bottom A Fig Replacing Magnet Assembly B B C Step 9: Remount case cover making sure that its sealing O- ring is properly in its groove. Install four socket head cap screws and tighten to 100 in-lbs. for 9.0C and 1.5M meters or 150 in-lbs for 3.5M, 5.5M, 7M or 11M meters. Step 10: Orient manufacturer s badge to show gas flow arrow to the adjusted direction. Step 11: Refer to Instruction Manual IM 5750 supplied with meter to continue with standard rotary mounting instructions. Reverse Flow kits are available for older meters in the field by ordering the part numbers as listed in the table on page 3-7. Note: Each reverse flow kit contains oil slinger/hub, associated set screw for mounting and new meter badge. PROVING OPERATIONS The permanently lubricated Continuous Mechanical Temperature Compensator (CMTC) provides a means for convenient standard-scanning methods used for performing meter proving. The adjustment of the compensated odometer is continuous therefore, does not require consideration of adjustment bursts provided in some devices. The odometer wheel positioned at the right hand side next to the 10 cu. ft. number wheel on both odometers, non-compensated and compensated, can be scanned through the number wheel aperture of the odometer housing. The odometer wheels, also referred to 3-6

29 READING X 100 = CU. FT. TEMPERATURE COMPENSATED VOLUME BASE TEMP. 60 F (15.6 o C) NON - COMPENSATED VOLUME READING X 100 = CU FT 3 Standard, ETC, CMTC General Description Horizontal Flow Configuration (Right to Left) Vertical Flow Configuration (Upward)) Fig Gas Flow Diagram For Reverse Flow Configuration as proving wheels, provided for scanning, feature a white square target-mark used for scanning. One revolution of both wheels, non-compensated and compensated, represents 10 cubic feet (between the target-mark on the wheels). Accessibility for scanning through the clear plastic cover is provided. An alternate volume scanning is provided for the compensated volume at the CMTC center drive shaft coupling visible and accessible for scanning through the clear area of the cover end face. The coupling features a white target mark that provides 10 cubic feet compensated volume between two target-marks representing one revolution. The volume per revolution of the odometer wheels and center drive used for scanning is identical for all meter sizes. Reverse Flow Kits Meter Kit Part Number 8.0C 52918K C 52918K001 11C 52918K M 52918K001 2M 52920K M 52920K M 52921K001 7M 52932K001 11M 52945K001 16M N/A Proving the CMTC Meter on a Dresser Model 5 Transfer Prover (Corrected Volume) There is no need to remove the CMTC Lexan cover. Place the optical sensor in position to read the 10 ft. proving wheel on the far right of the Corrected Volume odometer faceplate. The proving wheels of both odometers feature red dots in 1 cubic foot increments, a red rectangle 5 cubic foot mark, in addition to the white square target-mark to ease visual verification of rotation. Connect the upstream and downstream pressure taps. Connect the temperature probe to the upstream side. On the Roots PC Prover executable file: 1. Configure and run a meter test 2. Prover Capacity: 2M, 5M, 10M, 80M (select one capacity depending on the size of meter to be tested) 3. Test Control Mode: ID OPTO or Manual (select one depending on the type of pick-up being used. Ex.: OPTO= optical pick-up) 3-7

30 Standard, ETC, CMTC General Description 4. Meter Output: UC, TC, PC, PCTC select Diaphragm TC (continuously compensated) 5. Pulses/Test Volume: 2 Pulses, 20 cu. ft. minimum (recommended depending on size of meter) 6. Flow Rates: 100%, 60%, 30%, 10% (recommended) Ref. 1.5M meter capacities: 1500, 900, 450, Base Temperature: 60 0 F. 8. Conduct the test. Temperature-Compensating Accuracy The CMTC accessory can provide a temperature correcting accuracy of gas volume within +/-0.5% with respect to the theoretical correction for a flowing gas temperature range of - 20 F to 120 F. The accuracy test of the CMTC accessory is determined by operating the device with the temperature transducer sense bulb submersed in a temperature stabilized bath using test points according to ANSI B109.3 Para Type III. A combined accuracy test, meter with CMTC accessory, at flowing gas temperature according to ANSI B109.3 Para Type I is a standard factory test. Attainable combined accuracy over a range of 20 F to 100 F is within +/-1%. CMTC Operational Check 1. Using an accurate certified temperature-measuring device, record the stabilized gas (or air) temperature flowing directly into the meter inlet port. 2. Compare that reading to the acclimated meter s CMTC indicating temperature dial on the front of the meter under the lexan cover. Both readings should agree within +/- 4 0 F. 3. Example A) If both readings were the same i.e F ( C) and a volume of 200 ft 3 was ran across the meter, both the uncorrected and corrected register readings would both increase by 200ft 3. Reason why? All commercially used, non-temperature compensated natural gas meters are designed to measure gas flow(s) at 60 0 F ( C). Therefore, a temperature compensated meter at 60 0 F ( C) should measure the same increase in volume on both of its corrected and uncorrected register displays. 4. Using Charles Law (Basic Gas Laws) which states the Volume of given mass of gas is directly proportional to its absolute temperature with the equation: (Where 60 0 F = on the Rankine temperature scale) Base Temp Rankine Gage Temp (F degrees) F = Volume Multiplier 3-8

31 Standard, ETC, CMTC General Description Therefore: 60 0 F F = 520 R (base temp.) 60 0 F F = 520 R (gage temp.) = 1 (Volume Multiplier) 5. Example B: Using the above equation with a temperature variant from 60 0 F base Temperature. Lets say the air flowing into the meter is ambient shop air with the meter also acclimated to 72 0 F ( C). Therefore: 60 0 F F = 520 R =.977 (Volume Multiplier) 72 0 F F = 532 R If you ran 200 ft 3 across the meter at 72 0 F, your uncorrected reading would show a 200 ft 3 increase whereas the temperature corrected reading would only increase by ft 3 (200 X.977). 6. Remember, the colder the gas (air) temperature from 60 0 F base temperature, the greater the Volume Multiplier will be. Example: Using 40 0 F (4.4 0 C) gas or shop air; Therefore: 60 0 F F = 520 R = 1.04 (Volume Multiplier) 40 0 F F = 500 R If you ran 200 ft 3 across the meter at 40 0 F, your uncorrected reading would show a 200 ft 3 increase whereas the temperature corrected reading would increase to 208 ft 3 (200 X 1.04). METER SHOP TEST PROCEDURES A meter shop motor driven test fixture will be needed for the following test procedure. Place the case cover/bulb and bellows transducer/temperature compensator assembly in a temperature bath to regulate the transducer temperature with recirculating fluid. (Fig. 3-18) Set the motor on the test fixture to engage the spur gear driving the cylinder. Position the photogate sensors to read the proving wheels (white bar with no numbers) on the compensated and uncompensated indices. These sensors are to be connected to electronic counters that display the time between each rotation of the proving wheel Temperature Bath Set the bath temperature to 60 0 F. Set the motor output speed on the test fixture to approximately 350 R.P.M. Zero the counters and record the time for each index to count pulses as indicated on the following page. 3-9

32 Standard, ETC, CMTC General Description Temperature Error Factor 9.0C 3 counts seconds 1.5M 3 counts seconds 3.5M 3 counts seconds 5.5M 3 counts seconds 7.0M 5 counts seconds 11.0M 5 counts seconds + Error = Over-registration - Error = Under-registration 3-10 Fig Meter Shop Test Fixture Counterclockwise for INCREASING speed. 100 A B Clockwise for DECREASING speed. Fig Adjustment Bracket & Collar Adjusting for Temperature Error Factor If the Corrected counter is indicating a faster time than the Uncorrected counter, loosen the #4-40 socket head cap screw (A) in the adjustment bracket and turn the adjustment collar (B) clockwise. (Looking at the hex face as shown in Fig. 3-19) If the Corrected counter is indicating a slower time than the Uncorrected counter, turn the adjustment collar counterclockwise. Three quarters (3/4) turn of the adjustment collar results in an error exchange of approximately 1%. Tighten the #4-40 Socket head cap screw after the adjustment is made. Again, zero the counters and record the time for each index to count pulses as listed in the Temperature Error Factor table above. Reset the counters to count 50 pulses and record the average temperature over the length of the test. Calculate the temperature factor error from the table on the previous page. If the error is less than +/- 0.75% the calibration process for this temperature bath is complete. If the error is equal to or greater than +/-0.75%, repeat the adjustment procedures on the adjustment bracket and recalculate temperature error factor. 0 0 Temperature Bath Set the bath temperature to 0 0 F. Keep the motor output speed on the test fixture at approximately 350 R.P.M. Zero the counters and record the time for each index to count appropriate number of pulses for the meter size. An acceptable temperature error factor is less than +/- 0.85%. If the error factor exceeds this rate, repeat the steps in Adjusting for Temperature Error Factor above Temperature Bath Set the bath temperature to F. Keep the motor output speed on the test fixture at approximately 350 R.P.M. Zero the counters and record the time for each index to count appropriate number of pulses for the meter size. An acceptable temperature error factor is less than +/- 0.67%. If the error factor exceeds this rate, repeat the steps in Adjusting for Temperature Error Factor above.

33 Inspection & Maintenance MAINTENANCE The following items should be inspected during routine field visitations to the meter site: Listen for abnormal sounds in the meter such as squeaks or grinding. Check all pertinent oil level sight plugs for correct volume and black or gray oil discoloration. Analyze the meters general condition: look for damage to the outer case due to vandalism, vehicles, weld burns, steam/water drippage, etc. Is there indication of excessive vibration? Is the meter still level within +1/16" per foot in all directional planes? Is there any deformation or strained inlet-outlet piping? Examine and clean all upstream strainers and filters. Check the rotary meter drive output for binds, i.e., ratcheting movement, no registration. Check the instrument drive for binds. Check the temperature compensator for accuracy, digital display, battery life remaining, and low battery warnings. Clock the meter for passage of predetermined volume of gas by using the dial on the register with the stop watch. Differential pressure 20%, 50% and 80% using a accurate test gauge. Record all pertinent data on the maintenance record included in the Appendix. 4-1

34 Inspection & Maintenance PROBLEM PROBABLE CAUSE SUGGESTED ACTION Excessive vibration: Build-up of foreign material Clean by flushing or replacement of on impellers replacement of parts Misalignment Level Meter Worn Bearings Replace/return to meter shop Worn Gears Replace/return to meter shop Impellers contacting body Rotate manually to verify free spin. Remove obstructions. Check for level. High Differential Heavyweight or too much oil? Check level and condition Dirt deposits on impellers Remove dirt by flushing Impellers out of time Retime impellers. Remove and return to shop for disassembly Impellers contacting body Rotate manually to verify free spin Low Registration Upstream or bypass leak Check all valves for leakage Non Registration Drive pin has sheared to Check for sheared pin accessory unit Bind in the accessory unit Start and stop meter; if counter or instrument does not operate, there is accessory failure. Obstruction within meter or associated piping Remove obstructions to rotation or flow. Remove meter and flush as necessary. 4-2

35 Instrument Drive The following accessories are available from American Meter for the American RPM Series Rotary Meter. Only qualified technicians should attempt installation procedures to the meter or the accessory unit. The American Meter Company can assist you with all rebuilding or repair of your meter at our factory. Part prices are available upon request. To order parts for the meter or accessory, please contact your sales office and be prepared to specify the following information: METERS- Model No. (Example 3.5M), Serial No. (From badge) 96 C ACCESSORY-Model No. (Example 3.5M), Type of Unit (Temperature Compensator) INSTRUMENT DRIVE ACCESSORY KIT The addition of an instrument drive accessory to an existing RPM Standard or CMTC Rotary meter require the replacement of the existing Lexan register cover with one allowing access to the wriggler drive. For more information contact your sales office. To install the instrument drive remove the four (4) allenhead screws which secure the clear lexan cover and replace with register cover having wriggler access. Make sure the largest clear window is placed over register counter(s). Tighten 4 screws. The Instrument drive kit will include the drive, O-ring and 4 allen-head mounting screws. Install the O-ring over the shoulder of the Lexan cover and place the instrument drive unit against Lexan cover to allow proper alignment of mounting holes. Install 4 supplied allen head screws and tighten (Fig. 5-1). Take care not to over tighten. X 100 DO NOT OIL THIS INDEX Fig. 5-1 Installing Instrument Drive Kit (optional X10 or X100) 5-1

36 Instrument Drive CORRECTED VOLUME MCF Optional Instrument Drive Kit(s). 4 different options which should be clarified prior to placing orders: 1:1 (X10) Clockwise wriggler rotation - Kit # 52994K051 1:1 (X10) Counter-clockwise wriggler rotation - Kit # 52994K052 10:1 (X100) Clockwise wriggler rotation - Kit # 52994K053 10:1 (X100) Counter-clockwise wriggler rotation - Kit # 52994K054 Optional Instrument Drive and Corrector Installation. The Instrument Drive Kit can be rotated on the meter providing 8 different locations allowing for vertical positioning of the Corrector. Top View Universal Top Plate & Register Housing Universal Top Plate 0 0 Universal Top Plate Mounting Holes (to Register Housing) (4) Threaded Mounting Holes (in Register Housing) (4) Threaded Instument Drive Mounting Holes (in Universal Top Plate) Register Housing Instrument Drive Shaft & Gearing Universal Top Plate 180 o Instrument Drive Shaft & Gearing Mounting Holes (to Register Housing) Register Housing NON - COMPENSATED VOLUME READING X 100 = CU FT 3 Register Housing 5-2

37 Appendix DIFFERENTIAL-RATE TEST DATA Meter Model Serial No. Utility Serial No. Location Date Installed Register Reading Lines Press. Gas Temp. Sp. Grav. Volume Measured Run Time Rate CFH (m3/h) Diff. Pressure Ins. W.C. (mm W.C.) % Chg. INITIAL TESTS - NEW METER PERIODIC CHECK LIST Date Tester 6-1

38 Appendix 6-2 Meter Model MAINTENANCE RECORD Serial No. Date Service

39 Appendix 6-3

40 A Complete Family of Gas Measurement, Pressure Regulation, and Filtration Systems Appendix Pilot-Loaded Regulators 1800 PFM industrial regulators are designed for applications requiring medium-to-high capacity, extremely precise outlet pressure control, and fast response to changing loads. See bulletin SB 8551 for more information. Rotary Meter with Prefabricated Sets Prefabricated new or replacement meter sets to customer specifications are available. Diaphragm Meters American Meter s compact, lightweight, aluminum case meters are designed to provide positive displacement accuracy for industrial or commercial loads. See bulletin SB 3510 for more information. Filters Filtration down to 10 microns. Protects meter and regulator stations from dirt and pipe scale damage. See bulletin SB for more information. Measurement Engineers Since 1836 Turbine Gas Meters High performance meters provide accurate measurement of high volume gas flow. Turbines are available from 3" to 12" line sizes and line pressure up to 1440 psig. See bulletin SB 4510 for more information. Represented by: Pre-Calibrated Replacement Cartridges Tested at atmospheric or actual operating pressure, pre-calibrated measurement cartridges are available for field service changes. Cartridges returned to the factory for re-certification and/or service are tested at five flow rates and at specified pressure. mi 6-4 MERCURY INSTRUMENTS INC Virginia Avenue Cincinnati, OH U.S.A. Phone Fax: American Meter Company has a program of continuous product development and improvement; and, therefore, the information in this bulletin is subject to change or modification without notice American Meter Company 09/05 2M A&A AMCO\IM Printed in U.S.A.

RPM Series Rotary Meter C-Class

RPM Series Rotary Meter C-Class PL 5800 TM RPM Series Rotary Meter C-Class Replacement s List Line Mounted Models 3.5M Non-TC Meter Shown AMERICAN METER 5 YEAR LIMITED WARRANTY RPM SERIES ROTARY METERS American Meter Co. Industrial Products

More information

ROOTS Meters Series B3 Meter Models 8C175-56M175

ROOTS Meters Series B3 Meter Models 8C175-56M175 ROOTS Meters Series B3 Meter Models 8C175-56M175 Refer to IOM-B3 for Complete Instructions IS:B3 3.03 RECEIVING, HANDLING AND STORAGE ROOTS rotary positive displacement gas meters are precision measurement

More information

NDM Rotary Gas Meter Installation and Operation Manual

NDM Rotary Gas Meter Installation and Operation Manual The NMT TM NDM Rotary Displacement Gas Meter is a positive displacement type of meter which, by means of two counter-rotating impellers and a counting mechanism, measures a known volume of gas with each

More information

FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.

FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc. FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS by John Michalak Romet International, Inc. INTRODUCTION Rotary gas meters have been in use for over sixty years in the natural gas distribution industry. Over

More information

Model 1100 Turbine Flow Meter

Model 1100 Turbine Flow Meter Model 1100 Turbine Flow Meter INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 www.hedland.com TABLE

More information

MODEL 1100 TURBINE FLOW METER

MODEL 1100 TURBINE FLOW METER MODEL 1100 TURBINE FLOW METER INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Phone: 800.433.5263 Fax: 800.245.3569 www.hedland.com 2 OPERATIONAL START-UP Fluid entering

More information

Series 100 Slam Shut Valve

Series 100 Slam Shut Valve IMP 8775 Series 00 Slam Shut Valve Sizes ", ", 4" Installation & Maintenance Instructions Read carefully and follow all instructions shipped with this regulator. The incorrect installation of this equipment

More information

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter PRODUCT FEATURES. Applications. Brief information. Operating Principle

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter PRODUCT FEATURES. Applications. Brief information. Operating Principle Connected Industrial Elster RABO Highly Accurate Rotary Gas Meter Applications Honeywell Elster has combined tried and tested product features of their RPM and IRM rotary meter product lines with new developments

More information

MODEL 900 IMPELLER-TYPE FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER MODEL 900 IMPELLER-TYPE FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155

More information

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Toll Free: 800.235.1638 Phone: 262.639.6770 Fax: 262.417.1155

More information

ADVANCED APPLICATION OF ROTARY METERS

ADVANCED APPLICATION OF ROTARY METERS ADVANCED APPLICATION OF ROTARY METERS Ron Walker Walker Technical Sales Inc. This paper will examine and explain several common characteristics of rotary meters and their use in the natural gas distribution,

More information

RABO Rotary Gas Meter

RABO Rotary Gas Meter RABO Rotary Gas Meter Instromet RABO Rotary Gas Meter 02 Elster Instromet Elster Instromet has combined tried and tested product features of their RVG and IRM rotary meter product lines with new developments

More information

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1. Watts Series CSM-9 Grooved/Flanged Flow Measurement/Balancing Valves Installation and Operating Instructions IS-CSM-9 Table of Contents Item Description Page. Installation of Valve Angle Design 2. Installation

More information

Series 867 Reduced Pressure Zone Assemblies

Series 867 Reduced Pressure Zone Assemblies RP/IS-F-867 INSTALLATION INSTRUCTIONS Series 867 Reduced Pressure Zone Assemblies 2 1 2" 3" (65 80mm) INDEX 867-NRS Installation Instructions....................................... 2-3 Service, Repair

More information

Installation and Maintenance Manual Series B3-HPC GE Meters

Installation and Maintenance Manual Series B3-HPC GE Meters Meters & Instruments Installation and Maintenance Manual Series B3-HPC GE Meters Models: Series B3-HPC: 1M740/1480 3M740/1480 5M1480 7M1480 11M1480 WARRANTY Seller warrants that (i) its products will,

More information

Refinery Supply Company, Inc.

Refinery Supply Company, Inc. Refinery Supply Company, Inc. OPERATING INSTRUCTIONS Super Pressure Dead Weight Tester Catalog No. 35260 Serving the Oil & Gas Industry since 1923 9133-A East 46th Street Tulsa, Oklahoma 74145-4823 Voice

More information

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER MODEL 200 MULTI-JET FLOW METER - For Water Applications - INSTALLATION & INSTRUCTION MANUAL 8635 Washington Avenue Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638

More information

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information Connected Industrial Elster RABO Highly Accurate Rotary Gas Meter Applications Honeywell Elster has combined tried and tested product features of their RPM and IRM rotary meter product lines with new developments

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

Operation and Maintenance Manual

Operation and Maintenance Manual BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may

More information

To ensure proper installation, digital pictures with contact information to before startup.

To ensure proper installation,  digital pictures with contact information to before startup. Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or

More information

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Pg. 1 of 10 PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TBH SERIES

More information

ZDM Positive Displacement Flow Meter User Instructions

ZDM Positive Displacement Flow Meter User Instructions ZDM Positive Displacement Flow Meter User Instructions USA 1801 Parkway View Drive Pittsburgh, PA 15205 PH 412-788-2830 Canada 9A Aviation Point Claire, QC H9R 4Z2 PH 514-428-8090 www.koboldusa.com ZDM_manual_05/17

More information

INSTALLATION AND OPERATING

INSTALLATION AND OPERATING Publication T5-704, Rev. 4 Dated: November 1, 2006 INSTALLATION AND OPERATING MANUAL T50-P TURBOTWIN Engine Air Starter AN 99-448 TABLE OF CONTENTS Section Subject Page 1.0 General Information. 1 2.0 Orientation

More information

DAP-625S and DAP-875S

DAP-625S and DAP-875S AIR CHAMP PRODUCTS DAP-625S and DAP-875S (i) FORM NO. L-20078-B-0501 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

cs200 series commercial / Industrial pressure reducing regulators

cs200 series commercial / Industrial pressure reducing regulators November 2013 cs200 series commercial / Industrial pressure reducing regulators P1188 Figure 1. Typical CS200 Series Pressure Reducing Regulator Features and Benefits Wide Range of Body Sizes and End Connections

More information

Dresser * Series B3-HPC Rotary Meter

Dresser * Series B3-HPC Rotary Meter GE Oil & Gas Dresser * Series B3-HPC Rotary Meter B3-HPC: 1M740/1480 3M740/1480 5M1480 7M1480 11M1480 Installation, Operation and Maintenance Manual imagination at work Table of Contents Limited Warranty...2

More information

15,000kg HYDRAULIC BOTTLE JACK

15,000kg HYDRAULIC BOTTLE JACK Product Code: 2013 OWNER S MANUAL PRODUCT CODE: 2013 15,000kg HYDRAULIC BOTTLE JACK Lifting Capacity 15,000kg Max. Lifting Height 447mm Min. Lifting Height 227mm Hydraulic Lift 125mm Screw Adjustment 70mm

More information

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies Sizes: 2 1 2" 10" (65 250mm) Installation Service Repair Kits Maintenance RP/IS-957/957RPDA

More information

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter OWNER S MANUAL Model 9880 Intrinsically Safe Air Velocity Meter LIMITATION OF WARRANTY AND LIABILITY Seller warrants the goods sold hereunder, under normal use and service as described in the operator's

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. Series 909 Reduced Pressure Zone Backflow Preventers Sizes: 3 /4" 2" (20 50mm) Installation Service Repair Kits Maintenance No. 1 1 2" shown Patent Number 4,241,752 IMPORTANT: Inquire with governing authorities

More information

GTS/GTX/E-Class Turbine Meters Installation, Operation and Maintenance

GTS/GTX/E-Class Turbine Meters Installation, Operation and Maintenance IM 20.3 GTS/GTX/E-Class Turbine Meters Installation, Operation and Maintenance Table Of Contents Page Definitions of Metering Terms...................... 2 General Description of Turbine Meters...............

More information

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BULLETIN 20-5100-68 BYPASS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES BYPASS ROTOMETERS SK bypass Rotameter systems are designed for the accurate measurement of fluid rate of flow in pipelines 11/2

More information

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers RP/IS-995 Sizes: 2" through 2" (5-50mm)! WARNING Read this Manual BEFORE using this equipment. Failure to read and

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442) Single-Position Detent Clutch DC Series (i) FORM NO. L-2017-A-001 In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are subject

More information

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2 to 1 1/2 add 2 1/2 to 'C' dimension. 428 Jones Boulevard Limerick Airport Business Center Pottstown, PA 19464 Phone: (610)495-5131 ax: (610)495-5134 www.watsonmcdaniel.com PAGE 28 INSTRUCTION PART NO. 2315400 C.R.3500 REV. 10 SIZE C B CENTER

More information

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve

More information

Industrial Turbo Meters, Sizes 2" through 6"

Industrial Turbo Meters, Sizes 2 through 6 Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product

More information

Colt Series C400, C500

Colt Series C400, C500 Colt Series C400, C500 RP/IS-A-C400/C500 C400 OSY Reduced Pressure Zone Assemblies Reduced Pressure Detector Assemblies Sizes: 2 1 2" 10" (65 250mm) Installation Service Repair Kits Maintenance For other

More information

Housing 3 GT/GTS Gas Turbine Meter

Housing 3 GT/GTS Gas Turbine Meter PL4802.2 Housing 3 GT/GTS Gas Turbine Meter 12 6 5 4 11 9 2 8 7 3 1 2 3 GT/GTS Gas Turbine Meter Housing Item No. Description Qty. Common To All Variations Part Numbers Product Variations 275 PSIG 1440

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL Publication T3-76, Rev. 1 Dated: May 9, 21 INSTALLATION AND OPERATING MANUAL MODEL: T3-I TURBOTWIN Engine Air Starter AN96-419 From Tech Development Inc 68 Poe Ave. Dayton OH 45414 Tel: (937) 898-96 Fax:

More information

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:TRQSMAN16 Table of Contents Contents Table of Contents... 2

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL Dated: May 10, 2001 INSTALLATION AND OPERATING MANUAL MODEL: T30-Y TURBOTWIN Engine Air Starter From Tech Development Inc AN96-425 6800 Poe Ave. Dayton OH 45414 Tel: (937) 898-9600 Fax: (937) 898-8431

More information

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1 TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES hle, ate and ale SECTION TSM 710.1 PAGE 1 of 8 ISSUE B CONTENTS Introduction....................... 1 Safety

More information

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA Series 774/774DCDA 774X/774XDCDA Double Check Backflow Preventer Double Check Detector Assemblies Sizes: 2 1 2 " - 12" (65-300mm) 774 4" - 12" (100-300mm) 774DCDA 6" - 8" (150-200mm) 774X/774X DCDA Installation

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications Bulletin 71.1 D103087X012 Type HSR December 2017 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications High Capacity Compact Design P1524_1 High Capacity Internal

More information

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy NorthStar TM brand Instruction Manual SLIM Tach SL56 1.125 Thru-Shaft Diameter Magnetoresistive Encoder Designed for GE Wind Energy Patent Pending *791-1061-00* Rev. B Page 2 Table of Contents Chapter/Paragraph/Illustration

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL 4D-200 REDUCED PRESSURE PRINCIPLE (RPZ) & MODEL 4D-700 REDUCED PRESSURE DETECTOR ASSEMBLY (RPDA) BACKFLOW PREVENTERS 2 ½ 10 Conbraco Industries Inc.

More information

Techcon Systems TS5000 Series Rotary Valve

Techcon Systems TS5000 Series Rotary Valve 10. SPARE PARTS AND ACCESSORIES 10.1 SPARE PARTS: The only spare parts available are: Fluid inlet fitting, O- ring and clean out screw. These items are included in the Valve cleaning kit part number: 5000-013-000

More information

COMPRESSED AIR LOADER MODEL: AL-1

COMPRESSED AIR LOADER MODEL: AL-1 COMPRESSED AIR LOADER MODEL: AL-1 Document: AL-1 IM 10-22-2011 TABLE OF CONTENTS Important Notices and Precautions 3 Quick Installation 4 Product Description 4 Principle of Operation 5 Unpacking and Inspection

More information

Full View Flow Indicator

Full View Flow Indicator Full View Flow Indicator Threaded and Flanged Process Connection Installation / Operation / Maintenance Manual P.O. Box 1116 Twinsburg, OH 44087 Phone: 330/405-3040 Fax: 330/405-3070 E-mail: view@ljstar.com

More information

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU Instruction Manual Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY 12072 1-800-833-0081 Fax 518-922-8997 www.anderson-negele.com Instrument Model Number Instrument Serial Number 2A 2AU

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) IOM-1088 03-16 Model 1088 Vacu-Gard Blanketing Valve ISO Registered Company SECTION I I. DESCRIPTION AND SCOPE The Model 1088 Vacu-Gard is a tank blanketing

More information

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL TABLE OF CONTENTS SYSTEM...... Warning........ Description...... Prior to Operation OPERATION... Main Components... Mechanical...

More information

WELDING FUME EXHAUSTERS & ARMS

WELDING FUME EXHAUSTERS & ARMS WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through

More information

PMV P36C AND P41C POSITIONERS ACTUATORS

PMV P36C AND P41C POSITIONERS ACTUATORS PMV P36C AND P41C POSITIONERS USED WITH DeZURIK PNEUMATIC ACTUATORS Instruction D10327 August 2012 Instructions These instructions provide information about Models P36C and P41C PMV Positioners. They are

More information

B58 Series Regulator Residential Regulator

B58 Series Regulator Residential Regulator B58 Series Regulator Residential Regulator The B58 regulator is ideally suited for use where inches of water column or pounds delivery pressure are desired for uses including utility services, small boilers,

More information

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND

More information

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models:

Stealth Electronic Manual ZTM1015 Installation & Maintenance. For Oval Gear Meter Models: Stealth Electronic Manual ZTM05 Installation & Maintenance For Oval Gear Meter Models: TS0 TS5 TS0 TS30 including : CC56 PIA EDB 80 PC58 PCDT58 PDB 80 DU53 PRT PDMB 80 ELNC PAC PMFC Meter Model No.: TS

More information

User s Manual D-Series Blowers and Exhausters

User s Manual D-Series Blowers and Exhausters User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1

More information

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516 COMPANY Pneumatic Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516 Technical Specifications Measuring Accuracy ±2.5% of full scale

More information

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter

Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter Ventilation Testing/Balancing Model 8340 Intrinsically Safe VELOCICHECK Air Velocity Meter Operation and Service Manual 1980076, Revision E October 2002 Model 8340 Intrinsically Safe VELOCICHECK Air Velocity

More information

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company

More information

D-Series Blowers and Exhausters

D-Series Blowers and Exhausters Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC

More information

B57 Series Regulator Residential Regulator

B57 Series Regulator Residential Regulator B57 Series Regulator Residential Regulator The B57 regulator is ideally suited for use where inches of water column or pounds delivery pressure are desired for uses including utility services, small boilers,

More information

B57 Series Regulator Residential Regulator

B57 Series Regulator Residential Regulator B57 Series Regulator Residential Regulator The B57 regulator is ideally suited for use where inches of water column or pounds delivery pressure are desired for uses including utility services, small boilers,

More information

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. Elecronic Preset Meter 2 Industrial Handheld Series Model EPM2-IND Standard Series IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE. IOM-139-02-EN (1-12) 53400-139 Rev.

More information

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M IMPORTANT 1. W. A. Kates flow rate controllers are designed to accurately regulate flows and are precision

More information

TOTALIZER-TRANSMITTER

TOTALIZER-TRANSMITTER TOTALIZER-TRANSMITTER MODEL TR04-2 OPERATION AND MAINTENANCE MANUAL PARTS LIST FEATURING: *SEALED HOUSING *STANDARD TOTALIZER ASSEMBLY *MAGNETICALLY ACTUATED REED SWITCH 3255 WEST STETSON AVENUE HEMET,

More information

FIXED DEPTH INSERTION METER INSTRUCTIONS

FIXED DEPTH INSERTION METER INSTRUCTIONS UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken

More information

JET METER INSTRUCTIONS

JET METER INSTRUCTIONS UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken

More information

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2-10 MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS GENERAL INFORMATION INSTALLATION & OPERATION INSTRUCTIONS 1. Clean the lines upstream of valve particles larger than 1/16" diameter (welding slag, pipe scale and other contaminants). Griswold Controls

More information

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)

More information

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Instruction Manual. RZ Positive Displacement Flowmeters 2AU Instruction Manual AndersonInstrumentCo.Inc.. 156AuriesvilleRoad Fultonville,NY12072 1-800-833-0081 Fax518-922-8997 Www.andinst.com InstrumentModelNumber InstrumentSerialNumber 2A 2AU 3A RZ Positive Displacement

More information

Positive Displacement Flowmeters GM020 series instruction manual

Positive Displacement Flowmeters GM020 series instruction manual MS244G 0603 0003 Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX To the owner Thank you for purchasing a GPI GM Series Flow Meter. Please take a

More information

Guardian Steel Gear Shaft Coupling

Guardian Steel Gear Shaft Coupling Guardian Steel Gear Shaft Coupling P-8609-GC GUA-MRK-DOC-026 Service & Installation Instructions TABLE OF CONTENTS NOTICES AND WARNINGS PAGE 2 SECTION 1 COUPLING OVERVIEW PAGE 3 SECTION 2 TOOLS/MATERIALS

More information

Installation and operation manual Series: imrm and imrm-twin

Installation and operation manual Series: imrm and imrm-twin Page 1/27 Document Conventions Warning Indicates a procedure that has to be followed strictly as contravention could result in escaping gas, and cause property damage, serious injury or death Caution Highlights

More information

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2 10 IOM-F-860_880V INSTALLATION, OPERATION, MAINTENANCE Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10" 860 880V Standard Configuration 880V Vertical Configuration INDEX Vandalism..............................................

More information

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION 30/8.5.1 INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION VKP PILOT OPERATED PRESSURE REDUCING VALVE 12501 Telecom Drive, Tampa, Florida 33637 1. Introduction The Class VKP pilot-controlled steam

More information

REPAIR PROCEDURES MANUAL

REPAIR PROCEDURES MANUAL REPAIR PROCEDURES MANUAL PVX Series Vane Pumps A Design Series Step-by-Step Guide to Troubleshooting and Repairing PVX Series Vane Pumps Introduction Thank you for choosing Continental Hydraulics PVX Vane

More information

IOM Manual. IOM Manual. Series 76/77.

IOM Manual. IOM Manual. Series 76/77. IOM Manual IOM Manual Series 76/77 www.flowlinevalves.com Flow Line Valve and Controls, L.L.C. 110 Main Project Road Schriever, LA 70395 P.O. Box 677 Schriever, LA 70395 Phone 985-414-6004 * Toll Free

More information

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL Standard Pump Ultra Mass High Viscosity Batch Control System Description Standard s Drum Pumps are designed to transfer a variety of materials from 55 gallon drums and tanks. Standard Pump offers several

More information

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product.

Operation & Maintenance Manual. Sludge Vac. Visit our Website for more information on this product. DIVERSITECH Operation & Maintenance Manual Sludge Vac Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy, Montreal, Quebec H8T 3M2 Tel: 1.800.361.3733 Fax:

More information

Series B3 ROOTS Meters Models:

Series B3 ROOTS Meters Models: IOM:B3 10.03 Series B3 ROOTS Meters Models: Series B3: 8C175-56M175 Series B3-HP: 1M300-3M300 Series B3-HPC: 1M740-3M740 Series B3-HPC: 1M1480-7M1480 WARRANTY Seller warrants that (i) its products will,

More information

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1 Model 1504-50 15 Ton Hand Carry Axle Jack P/N: CJ67D0250-1 Operation and Maintenance Manual with Illustrated Parts List 2222 South Third Street Columbus, Ohio 43207-2402 Phone (614) 443-7492 FAX (614)

More information

RUN ACCUM. TOTAL STOP BAT LOW HIGH

RUN ACCUM. TOTAL STOP BAT LOW HIGH TURBOPULSE TURBINE FLOWMETER INSTRUCTION MANUAL gal RUN ACCUM. TOTAL STOP BAT LOW HIGH RESET > PROGRAM ENTER ACCUM TOTAL ^ RATE TOTAL TP050 TABLE OF CONTENTS 1. INTRODUCTION Overview 1 1.1 Model number

More information

Series B3 ROOTS Meters Models:

Series B3 ROOTS Meters Models: IOM:B3 1.06 Series B3 ROOTS Meters Models: Series B3: 8C175-56M175 Series B3-HP: 1M300-3M300 Series B3-HPC: 1M740-3M740 Series B3-HPC: 1M1480-7M1480 WARRANTY Seller warrants that (i) its products will,

More information

Section 10 Chapter 17

Section 10 Chapter 17 Section 10 Chapter 17 24 Valve, 8.3 Liter Engine Air Intake System Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cummins engine codes. These engine codes have no meaning to New

More information

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B CLIF MOCK TM Model 5030 Orifice Fitting User Manual Manual No. 25165003, Rev. B 2007 Cameron International Corporation ( Cameron ). All information contained in this publication is confidential and proprietary

More information

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i) USER MANUAL NEMA 48C Flange Mounted, Enclosed, Clutch Brake FMCBE Model 500 (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual

More information

An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features

An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features An Illustrated Manual: Constant Level Lubricators Function, Installation, and Features Constant Level Lubricators Table of Contents Overview Typical Applications and Industries..........................

More information

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM) SERIES 60 SERVICE MANUAL 4.2 WATER PUMP (GEAR CASE MOUNTED - 1991 AND LATER) (GCM) The centrifugal-type water pump circulates the engine coolant through the cooling system. The pump is mounted on the rear

More information

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL LILLY ENGINEERING COMPANY 217 CATALPA STREET P.O. BOX 173 ITASCA, ILLINOIS 60143 630-773-2222 FAX: 630-773-3443 www.lillyengineering.com

More information

INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS

INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS INSTRUCTION MANUAL MODEL 213, 214, 215 and 216 POSITIVE DISPLACEMENT FLOWMETERS TABLE OF CONTENTS Do s and Don ts.................................. Pg 2 General Description...............................

More information

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi R SPX Division 655 Eisenhower Drive Owatonna MN 55060 Phone: (507) 455-7000 Tech. Serv.: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (800) 533-6127 Fax: (800) 283-8665 International Sales: (507) 455-7223

More information

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Maintenance Information

Maintenance Information 16572679 Edition 2 May 2014 Air Drill QP Series Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these potentially

More information