Digital Electrical Meter. User Manual
|
|
- Doreen Caldwell
- 6 years ago
- Views:
Transcription
1 Digital Electrical Meter User Manual
2
3 1 Structure characteristics and working principle Modular structure design, optional auxiliary function.mcu sampling the input signal, Data processing for sampling results,the meter will display According to the keyboard programmed voltage and current ratio. 2 Technical performance and parameters Sheet 1 Technical performance and parameters Technical parameter Measurement network Index 单相 Nominal input AC Voltage AC Current AC 100V 220V 380V 500V AC 1A 5A Input charac terist ics Linear range Voltage Current Frequency Power Factor 10%~120% Nominal input value 1%~120% Nominal input value 45Hz~65Hz 0.1(Delay)~1.0~0.1(Leading) Continue:1.2 times, Allowable Overload Instantaneity:Voltage 2times/5s, Current10times/5s Output charac terist ic Other charac terist Accuracy grade Data update Display mode Auxiliary power supply power consumption Display HHHH when exceed the rated value Voltage, current, active power, power factor 0.5 grade,frequency 0.1 grade Reactive power 1 grade 3 times/second 4 bit digital tube LED display, automatic decimal point shift AC220V 50Hz <5VA
4 ics electroma Electrostatic discharge immunity 4 Grade(GB/T ) gnetic Electrical Fast compatibi Transient Burst 2 Grade(GB/T ) lity Burst Immunity Surge immunity 4 Grade (GB/T ) Insulation strength Input and auxiliary power supply AC2.5kV,1min Security features insulation resistance >100MΩ Heat resistance and flame retardant Terminal:960 Case:650 actuation duration:30s Temperature Operation:-25~55,Storage:-25~50 environme nt Humidity 93%RH,Non-Dewfall,Non corrosive gas Altitude 2500m Installation method Embedded 3 Installation Embedded installation mode, according to the appearance and installation dimensions of the instrument, the installation screen is provided with a hole, and the instrument is embedded into the installation hole, and the clamping piece is clamped into the instrument corresponding to the clamping groove. 3.1 Connection Should check the connection wiring is correct,before use the meter. If the manual
5 wiring diagram and instrument case on the wiring diagram is different, please refer to the wiring diagram on the instrument case Input signal connection A N 单相 CT A B C N 三相四线 CT A B C 三相三线 CT 单相改成 SINGLE PHASE 中文改成 3-PHASE 4-WIRE 中文改成 3-PHASE 3-WIRE 1 2 L N 辅助电源中文改成 POWER SUPPLY 3.3 Connection Note Meter need to be applied to the auxiliary power supply (specifications see instrument signs) to work properly, please ensure that the power provided by the series of instruments, in order to prevent damage to the instrument The input voltage should not higher than the rated voltage, or should be considered the use of voltage transformer, voltage transformer should be one end of the grounding, in order to maintain convenience, the proposed use of wire. The voltage input is recommended to install the 1A fuse The input current should not higher than the rated current, or should consider the use of current transformer, current transformer secondary should one end of the grounding, in order to maintain convenient, it is recommended to use the wiring The meter have three type connection type. three-phase three line, three-phase
6 four wire and single-phase wiring, field wiring mode must be with the instrument settings of wiring in a manner consistent with, and to ensure that the input voltage and current phase sequence and wiring diagram is consistent, otherwise data of measurement is incorrect 3.4 Interface and operation instructions Interface instructions The meter have five LED display,the The first three rows is use to display the current,the forth row is to display Current L1,L2,L3 is the phase voltage.when two light is working it means line voltage, L1+L2 both light it means the first phase, L2+L3 means the second phase,l1+l3 means the third phase,the meter will update every 5 seconds,the fifth row is to display the frequency operation instructions Data record display:push will display the max of the value and the H light will working,push 2 times of the will display the minimum value. Notice:The maximum minimum value cant record,it only display the period when the meter is powered.if it outage then meter will clear not record Programming parameter description is use to move the cursor, is use to increase the value push the same time can reduce the value
7 Push SET,you will need to input the password,the initial password for the product is 0.then push SET,we will into the,it will have 6 code as the sheet below. Each code have function,we can use to switch the code,the SET is to enter the code And save the setting,and is use to back to the previous menu. Para mete r Parameter code Parameter name Setting range description type Set the input circuit voltage ratio. When the voltage is through the Voltage ratio 1~4999 mutual transformer, Pt = Primary circuit rated voltage/two circuit rated voltage; If voltage input directly,pt=1 Set the input current ratio When the voltage is through the Syst em Current ratio 1~9999 current transformer,ct = Primary circuit rated current/two circuit rated current; If current input directly,ct=1 Setting the input network: Input network 0~2 0:Three-phase four wire, 1:Three-phase three wire, 2:Single-phase Switch display time 0~20(s) Parameter display, When the setting time is longer than 4S, the display parameters start to show
8 Password 0~9999 Setting system password Clear the max and min value 0~1 0:no, 1:yes Abnormal display instructions HHHH: The measured value is out of range.the voltage or current input exceeds 1.2 times of rated value of the instrument ----hyphens:input disconnection indication, ----Upper cross bar:the measured value is beyond the display range of the meter Attention 5.5.1Please confirm the meter power supply, whether the input signal is in the range, the terminal connection is correct and solid.before using the power supply Meter need to preheat 15min to accurately measure 5.5.3Instruments should not be hit, collision and violent vibration, the use of the environment should meet the technical requirements 6 Maintenance Instrument should be verification at least one time each year, if the meter deviation exceeds the range, usually it cause by damp, dust or corrosive gases, we can dry and clear to recovery the accuracy.if it not works need send back to the factory to repair. The meter have guarantee for 12 months, user should follow the instructions.if found
9 quality problems, the manufacturers will give free repair or replacement. 7.1 Packing Packaging should be environmental protection materials, packaging requirements should be consistent with the provisions of GB/T 7.2 Transportation and storage The transport and storage of shall conform to the provisions of JB/T. Storage temperature of the environment is -25 degrees Celsius to 50 degrees Celsius, the relative humidity of not more than 85%, and the harmful substances contained in the air is not enough to cause the corrosion of the instrument.
PSW102 type CT powered protection unit
PSW102 type CT powered protection unit Summary PSW102CT self-powered protection device is a 10Kv feeder protection device which has the function of over current, fast breaking protection and grounding
More informationHGM501 Gen-set Controller USER MANUAL. Smartgen Technology
HGM501 Gen-set Controller USER MANUAL Smartgen Technology Contents 1. 2. 3. 4. 5. 6. 7. 8. 9. OVERVIEW... 4 PERFORMANCE AND CHARACTERISTICS... 4 TECHNICAL DATA... 5 OPERATION... 6 4.1. BUTTON DESCRIPTION...
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,
More information1 Scope. 2 Based on written. 3 Product. 4 Parameters Index. This specification applies to the lithium-ion rechargeable battery.
1 Scope This specification applies to the lithium-ion rechargeable battery. 2 Based on written a: GB/T 18287 2000 General specifications of cellular phone lithium-ion battery ; b: GB/T 3873---1983 General
More informationHGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...
CONTENT 1. SUMMARY...4 2. PERFORMANCE AND CHARACTERISTICS...4 3. SPECIFICATION...5 4. OPERATION...6 4.1. DISPLAY PANEL...6 4.2. LCD ICON INSTRUCTION...7 4.3. DISPLAY INSTRUCTIONS...7 4.4. DISPLAY DESCRIPTION...8
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201705) E-15 Uninterruptible Power Systems (UPS) Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,
More informationHGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic
HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...
More informationHGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology
HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951
More informationNB/T Translated English of Chinese Standard: NB/T ENERGY INDUSTRY STANDARD
Translated English of Chinese Standard: NB/T 33001-2010 www.chinesestandard.net Sales@ChineseStandard.net ICS 29.200 K 81 NB ENERGY INDUSTRY STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA NB/T 33001-2010 Specification
More informationNational Standard of the People s Republic of China
Translated English of Chinese Standard: GB/T18287-2013 Translated by: www.chinesestandard.net Wayne Zheng et al. Email: Sales@ChineseStandard.net ICS 29.220.01 K 82 National Standard of the People s Republic
More informationMX1S Matrix Converter
MX1S Matrix Converter Energy-Saving Medium-Voltage Drive with Power Regeneration 4.16 kv, 500 to 4000 HP, UL Listed Also available in 3 kv and 6kV Class Certified for ISO9001 and ISO14001 CERTI F I ED
More informationHGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL
HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationTechnical Specificaions. kwh Energy Meter
Technical Specificaions of kwh Energy Meter (SPK300) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number
ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationSola/Hevi-Duty S3K Series Mini-Tower UPS
Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY
CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS
More informationRT2DB Excitation and voltage regulation system for synchronous generators
s RT2DB Excitation and voltage regulation system for synchronous generators Fully digital. Parameter settings done by software. Self monitoring routines. Maintenance free. High reliability. Excellent dynamic
More informationAME. Rectifier - Battery charger. Industrial applications: Key features:
Rectifier - Battery charger AME VRLA batteries, flooded battery or Ni/Cd with output voltage from 24, 48, 110, 220 Vdc up to 150A Industrial applications: Oil&Gas (Petrochemicals Offshore, Onshore, Pipelines);
More informationFortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state
More informationMenu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents
Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationCobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications
Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System
More informationVert-X 31E - 24V / 4-20mA. Applications Concrete pump Access control system Fork lift
Sensor principle MH-C MH-C2 Electrical data Measuring range 0... 360 0... 360 Indep. linearity (typ.) % of meas. range ±0.3 ±0.3 Max. hysteresis 0.1 0.1 Resolution bit 12 14 Max. repeatability 0.1 0.1
More informationWhad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF
Manuel d installation Installation manual Part. LE05733AA-07/12-01 GF Index 1 Introduction 18 2 Conditions for use 19 3 Installation 20 4 Visual and acoustic warning signals 22 5 ups diagnostic software
More informationPower Lynx 3 Uninterruptible Power System (UPS) Technical Specifications
Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible
More informationClamp Earth Tester MET-2. Instruction Manual
Clamp Earth Tester MET-2 Instruction Manual Thank you very much for selecting our clamp earth tester. This model is complex instrument and employs a very reliable mechanical/electronic design. Before you
More informationIlluminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System
Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical
More informationLiquid Turbine Flow Meter OwnerÊs Manual
Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...
More information12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER
12/24 VOLT AUTOMATIC SOLAR CHARGE CONTROLLER P/No.s SC320 & SC330 WARNING Please read these instructions completely prior to installation. Lead acid batteries can be dangerous. Ensure no sparks or flames
More information(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2
Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.
More informationFortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting
More informationSecurity Plus Online Uninterruptible Power Supply
Security Plus Online Uninterruptible Power Supply 1 2 GENERAL SAFETY INSTRUCTIONS Warnings in this manual appear in any of four ways: DANGER Danger- The danger symbol is a lightning bolt mark enclosed
More informationTechnical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality
GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationShenzhen Sine Electric Co., Ltd.
Page 1 of 5 Favorite Contact 中文 Please enter key words 提交查 Home Products Solutions Service About us Products EM500 Open loop Inverter Your current location:home > Products Standard Inverters EM500 Open
More informationSB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320
Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax
More informationMODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )
Final Control Elements SERVO-TOP II ELECTRONIC ACTUATOR (linear type; max. thrust 5000 N) Functions & Features Control valve actuator drive I to I positioner incorporated Lightweight, compact design High
More informationIntelligent torque meter tester
Intelligent torque meter tester Before using this product, please read the instructions carefully, which will help improve the efficiency of your use of this product Contents 一 About HP Series Torque Meter...2
More informationINSTALLATION INSTRUCTIONS
Page 1 of 2 Ref: IW012346 Rev 4 July 03 Indicators Saxon & Fiesta Series Products Covered 012-**, 013-**, 014-** & 016-** Installation The product should be panel mounted using the mounting kit provided.
More informationVS Range Gamme VS. 100% electronic voltage sensors. Capteurs de tension 100% électronique. Technical argumentation. Argumentation technique
Technical argumentation Argumentation technique VS Range Gamme VS 1SBC146011C1701 Technical Presentation VS range 1.0 - Version 1.0 100% electronic voltage sensors Capteurs de tension 100% électronique
More informationTechnical specifications
Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith
More informationST Wiring diagram. Product description. Temperature controller. Order number
ST7-31.3 Temperature controller Order number 9154.12 Wiring diagram Product description The switching exits of the thermostatic controller can be programmed as -two-point controller with alarm -three-point
More informationPowerValue 11/31 T kva
Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power
More informationElectronic pressure switch with two switching outputs
Electronic pressure switch with two switching outputs RE 30278/04.14 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /2/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code 2
More informationPanel Meters and Accessories Digital Panel Meter
Digital Panel Meter - SE - - X 2 3 4 5 6. Product code 2. Input Signal Mode 48--48X48 72--72X72 96--96X96 94--96X48 3. Function Mode I--current U--voltage P--active power Q--reactive power H--power factor
More informationPressure transmitter JUMO dtrans p02
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationMarketing Management Team of Europe
Emerson Network Power Liebert NXe UPS GUIDE SPECIFICATIONS For a 10 to 20 kva (50 or 60Hz) Parallelable Digital Uninterruptible Power Supply (UPS) System - 1 - Contents 1.1 SUMMARY... 3 1.2 STANDARDS...
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE
More information7E x0. Nominal current 5 A (32 A Maximum) 1-phase 230 V AC 17.5 mm wide
Features 7E.23.8.230.00x0 kwh Energy meter 1-phase with multi-functional LC-Display Type 7E.23 5(32) - 1 module wide Complies with EN 62053-21 and EN 50470 Display indicates total consumption, partial
More informationSIGMA SERIES DE METER
SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current
More informationUSER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD
HGM400 Series Genset Controller (HGM410/HGM420) USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENTS 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATION... 9 4.1
More informationMCD 200 Series Soft Starters
MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When
More informationLS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL
EPSOLAR LS1024BP/ LS2024BP Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation, use
More informationElectronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:
Electronic pressure switch Type HEDE 10 RE 30277 Edition: 2017-02 Replaces: 2016-06 Component series 3X Maximum operating pressure 600 bar Features Suitable for measuring pressures in hydraulic systems
More informationTop Microsystems Proprietary Specification P/N: A190047LV6 FSM RB VA.1 SPECIFICATION
Top Microsystems Proprietary Specification P/N: A190047LV6 FSM 111010RB-091010VA.1 SPECIFICATION Slim Power Adapter Universal AC Input 90W 19VDC 4.7A Output P/N: A190047LV6 FSM **Specification Approval**
More informationUPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES
UPS UPS MODULAR THREE-PHASE from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES Modular and upgradable with power from 10 to 60kVA in compact structures with a reduced
More informationSuitcase solar power system
Suitcase solar power system 一 Product features 1. This system with microprocessor and special control algorithm to make intelligent control into reality. Which is a nice power system for outdoor working,
More informationCENTAURI ENERGY SERVER TECHNICAL DATA kw POWER
Chassis Inverter power Rated input Rated output Battery pack Safeties Environment Others Input Voltage Lower Limit Input Voltage Upper Limit Power Input Current Output Voltage Output accuracy Transient
More informationElectronic pressure switch with integrated analogue output
Electronic pressure switch with integrated analogue output RE 30276/03.1 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /1/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear
More informationInstallation & Operation Manual
EDL175 Portable Event & Data Logger-Extended Range Installation & Operation Manual BG0447 REV. A3 LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument
More informationInsulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit
SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,
More informationABB central inverters PVS to 1000 kw
ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and end users who require
More informationIlluminator Series CR NEMA 3R
Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the
More informationHSC940 Genset Controller CONTENTS 1 OVERVIEW PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION KEY FUNCTIONS...
CONTENTS 1 OVERVIEW... 4 2 PERFORMANCE AND CHARACTERISTICS... 5 3 SPECIFICATION... 7 4 OPERATION... 8 4.1 KEY FUNCTIONS... 8 4.2 INDICATOR LIGHT... 9 4.3 AUTO START/STOP OPERATION... 10 4.4 MANUAL START/STOP
More informationFlowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control
Document No. 155-507 Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Description The Flowrite 599 Series SAX Non-spring Return (NSR), Electronic Valve Actuator
More informationGUANGZHOU GENY ELECTRIC CO., LTD
SZ-01A-K3E Single Phase Standard Meter User s Manual ( Ver. 1.0 ) China Metrology Certificate No. Guangzhou 01000113 GUANGZHOU GENY ELECTRIC CO., LTD Content 1. SUMMARIZE... 1 2. TECHNICAL PARAMETER...
More informationNotes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]
Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Ribbed Case Style 22VDC Isolation Wide 4:1 Input Voltage Range EN-522 Class B The
More informationAS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)
INSTRUCTI MANUAL DC ALARM (dual or quad alarm trip; field-configurable) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationEPS/ELA-Series User Manual EPS/ELA 250W
EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...
More informationDigital Multimeter User's Manual
Digital Multimeter User's Manual MS8239A MS8239A DIGITAL MULTIMETER Auto Power Off V HOLD 600 600 20 10A A m 10A 20m 2 m V MAX 10A/ 500V COM 600V CAT III IEC61010-1 12V 9V BATT. k 2M 600V MAX MAX ma/250v
More informationClutchsensor, 22mm PLCD, passive For Valeo. Product Specification. Clutchsensor, 22mm PLCD, passive For Valeo. 1 of 9
Product Specification 108-18719 23 Apr 2002 Rev A3 EC: EG00-1360-02 Clutchsensor, 22mm PLCD, passive For Valeo Clutchsensor, 22mm PLCD, passive For Valeo Tyco Electronics Corporation, Harrisburg, PA 17105
More informationVolt/mA Calibrator. Manual
Volt/mA Calibrator Manual Safety Information To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between any jack and earth ground. Make sure the battery
More informationUSER MANUAL. IPS home inverters with UPS function. IPS home inverter manual
USER MANUAL IPS home inverters with UPS function Suitable for UPS: - IPS300-SIN - IPS300-SIN-WM - IPS300-SIN-DC - IPS600-SIN - IPS600-SIN-WM - IPS600-SIN-DC - IPS1000-SIN - IPS1000-SIN-DC - IPS1600-SIN
More informationTRANSFORMER RECTIFIER
TRANSFORMER RECTIFIER voltage from the commercial electrical power grid or an engine-generator. A transformer with tap adjustments in the secondary side provides a method to reduce and adjust the output
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More informationE-Series and EF-Series Systems
E-Series and EF-Series Systems Site Preparation Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationMPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.
MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. - 1 - Table of Contents 1. SALIENT FEATURES...3 2.. PRODUCT INSTALLATION & PRECAUTIONS...3 2.1. PRODUCT INSTALLATION &
More informationAlpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter
Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target
More informationGB/T Translated English of Chinese Standard: GB/T
Translated English of Chinese Standard: GB/T18487.1-2015 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 43.040.99 T 35 GB/T 18487.1-2015 Replacing
More informationMERU Solar Off-Grid Inverters
1 kva / 2 kva Off-Grid Solar Inverters with LCD and LED displays 24 / 48 VDC battery versions for 1 kva and 48 VDC for 2 kva Pure sine wave with highest efficiency Fully configurable (PV / Grid priority
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More information201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010
INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODELS 201A 201A-9 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685 BE SURE POWER
More informationEU RO Mutual Recognition Technical Requirements
1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.
More informationISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
More informationPiezoresistive single crystal silicon pressure transmitter
Product introduction Description Piezoresistive single crystal silicon pressure transmitter 305PI TSD single crystal silicon pressure transmitter is a high performance pressure transmitter with international
More informationSION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG
Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction
More informationSeries 230 Automatic Transfer Switch
Series 230 Automatic Transfer Switch Product overview The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load
More informationMedium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A
Medium voltage compact switchgears rated voltage 12 and 25 kv rated current 400 and 630 A 1 General The new air-insulated DRIESCHER medium voltage compact switchgears are ideal for application in secondary
More informationMerih DDCA60 Operation and User Manual I Merih Asansör A.Ş.
1. WARNINGS! CAUTION This manual contains user guidelines for Merih DDCA60 hardware version v1.05 and software version v1.03. This document will be updated with differences result from version differences.
More information1. WARNINGS CAUTION BEFORE FIRST USE GENERAL NOTE. Merih DDCA60 Operation and User Manual I Merih Asansör A.Ş.
1. WARNINGS! CAUTION This manual contains user guidelines for Merih DDCA60 hardware version v1.05 and software version v1.03. This document will be updated with differences result from version differences.
More informationBTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)
BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS) Programmable Automatic Transfer Switch Operation Manual Main Switch Rated Current 2P/3P/4P 250Amp 2P 400 Amp Main Switch Rated Voltage 690 Vac Taiwan Patent Number
More informationPower consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor
Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning
More informationMGE TM Galaxy TM 7000
MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with high adaptability to meet the unique requirements of Medium to Large
More informationINTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)
INTER PLANT STANDARD STEEL INDUSTRY I P S S SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION) Corresponding IS does not exist IPSS: 1-10-036-12 0 FOREWORD 0.1 This
More informationTechnical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationOn Grid Wind Turbine(wind solar hybrid)controller
On Grid Wind Turbine(wind solar hybrid)controller On Grid Wind Turbine (wind solar hybrid) Product Characteristics The product is manufactured according the JB/T6939.1-2004 industrial standard and GB/T
More information5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application
The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1
More information