Instruction Manual Princo Model L3545

Size: px
Start display at page:

Download "Instruction Manual Princo Model L3545"

Transcription

1 Instrumentation designed with the user in mind Instruction Manual Princo Model L3545 Remotely Adjustable Presence/ Absence Detector with NULL-KOTE Rev 2, 25 July 08 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL BLVD., SOUTHAMPTON, PA PHONE: or FAX: WEB SITE:

2 Table of Contents 1 DESCRIPTION General Description Functional Description Basic Features Sensor Flange Description SPECIFICATIONS L3545 Presence Absence Detector L600 Series Sensor Flanges INSTALLATION Inspection Mounting Partial-ring Flange (L632, L642, L652, L662) Location Full-ring Flange (L631, L641, L651, L661) Location Full-faced Gaskets & Flanges Sensor Head Mounting Spring-loaded Pin Grounding Electrical Connections Control Unit Sensor Head Installation in Hazardous Areas ADJUSTMENTS AND OPERATION Initial Checkout Calibration Adjustment Procedure - Conductive Process Materials Adjustment Procedure Non-conductive (Insulating) Process Materials Alarm Action Delay Operations and Adjustments Dead Band Adjustment Start Pump Push-button EQUIPMENT SERVICE Trouble-Shooting Guide Basic Electronic Checks Adjustment Problems Getting Help Warranty Statement...19 i

3 Table of Contents ILLUSTRATIONS Figure 1-1. Typical Pipeline Installation...3 Figure 2-1. Typical L631 and L632 Sensor Flanges...5 Figure 3-1. L3545 with Sensor Flange: Dimensional Drawing...6 Figure 3-2. Correct Horizontal Installation (Horizontal View)...7 Figure 3-3. Questionable Horizontal Installation (Horizontal View)...7 Figure 3-4. Correct Vertical Installation (Horizontal View)...7 Figure 3-5. Questionable Vertical Installation (Horizontal View)...7 Figure 3-6. Correct Horizontal Installation (Vertical View)...7 Figure 3-7. Questionable Horizontal Installation (Vertical View)...7 Figure 3-8. Spring-loaded Pin...8 Figure 3-9. L3545 Installation and Ground Checks...9 Figure Electrical Connections 115Vac & 230Vac Units...11 Figure Electrical Connections 24Vdc Units...11 Figure L3545 Electrical Installation...12 Figure 4-1. L3545 Adjustment and Indicator Locations...13 Figure 4-2. Conductive Process Calibration Procedure...14 Figure 4-3. Non-Conductive Process Calibration Procedure...15 ii

4 Section One: Description 1 Description 1.1 General Description The Princo Model L3545 Presence/Absence Detector is a remotely adjustable, RF impedance-sensing device which, when connected to any Princo L600 Series Sensor Flange, can be used to detect the presence or absence of process material within a pipeline. The L3545 unit, with Sensor Flange, is used for obstruction-less presence/absence detection of liquids and solids in all types of process systems, and for run dry protection of positive displacement pumps. The basic instrument consists of two separate devices - a Sensor Head and a Control Unit (see Figure 3-1). The Sensor Head is a modular electronic chassis, which is contained in a heavy-duty, cast aluminum, weatherproof, explosion-proof housing. The Sensor Head housing has a removable lid, which exposes the electronic chassis. The chassis is composed of two circular printed circuit boards that are held together by a removable system of mechanical spacers and electrical interconnects. The chassis is easily removed from the instrument housing, allowing convenient replacement of the boards, should troubleshooting be required. The Sensor Head housing, with internal electronic chassis, attaches directly to any one of the Princo L600 Series Sensor Flanges. An electrical and mechanical sensor connection is made by simply screwing the housing directly onto the Sensor Flange s upper hub NPT fitting. The Sensor Head electronic chassis performs the RF impedance measurement portion for the overall L3545 Presence/Absence Detector system. Here, the electrical impedance of the process material within the pipeline is measured and converted into an electrical DC signal. This signal is transmitted to the Control Unit via a two-conductor, shielded cable. The Control Unit is a modular electronic chassis, which is contained within a heavy-duty, weatherproof, NEMA enclosure. The Control Unit enclosure has a hinged cover that exposes the electronic chassis. The chassis is composed of one rectangular printed circuit board. Like the Sensor Head chassis, it is easily removed from the instrument housing, allowing convenient replacement, should troubleshooting be required. The Control Unit electronic chassis performs the operator interface functions, and the control portion for the overall L3545 system. The single printed circuit board performs a number of specific tasks that are relevant to these functions. The board incorporates a 13-position terminal block that provides interface to the external world. Three positions for power input, six positions for control relay output, three positions for connection to the Sensor Head, and one position for a remotely actuated start pump function. The board also contains the human operational interface, consisting of an LED status indicator, four control adjustments used to establish instrument configuration and calibration, and a push-button switch used to locally actuate the control relay to prime/start the pump. 1.2 Functional Description The Model L3545 is a part of a new generation of presence/absence detectors that incorporates advanced technology to bring forth enhanced performance. The unit is designed to protect progressive cavity or other positive displacement type pumps, plus any other pipeline related devices, which may be damaged by running dry. The basic function of the device is to detect the absence of process material within a pipeline, and to announce this absence by means of an alarmed set of relay contacts. These contacts, typically wired directly to the pump or a PLC, when alarmed, shut down power to the pump, and thus prevent the pump from the damaging effects of running dry. The Model L3545 can detect the presence or absence of virtually any process material that might flow through a pipeline, from low dielectric constant electrical insulators, to highly conductive electrical conductors. The mechanical nature of these materials can range from thin, low viscosity liquid materials to thick, viscous materials that severely coat the pipeline and inner surfaces of the sensor flange. The Model L3545 is used in conjunction with a Model L600 Series Sensor Flange. These sensors are available in two distinct types: Partial-Ring - for conductive process materials, and Full-Ring - for non-conductive process materials. The Sensor Head generates a low level, one MHz signal which is applied between the "active" sensing element on the inside diameter of the flange and the ground reference. With metal pipelines, the pipeline itself serves as the ground reference. With plastic pipelines, a metallic ground flange is required. The presence of the process material between the sensing element and the ground creates a change in the RF impedance that is sensed by the electronic circuitry. This resulting signal is amplified and rectified. The resulting DC voltage signal, which is proportional to the RF impedance, is transmitted to the Control Unit via a 3-wire, shielded cable. The Control Unit Model L3545 Instruction Manual Page 1 of 19 Rev 2, 25 July 08

5 Section One: Description compares this signal with a DC level established by the settings of the coarse and fine sensitivity adjustments. When the measurement signal passes above or below the set point, the relay contacts are switched accordingly. The unit is normally hard-wired at the factory for fail-safe low operation (relays are de-energized when pipeline is empty). Fail-safe high is available upon request. An enhanced feature of the Model L3545 is its superior temperature stability. Special electronic circuitry is incorporated into the L3545 that corrects for any changes in the measurement signal due to ambient air temperature influences on the highly sensitive electronic circuits. The result is a highly temperature stable presence/absence detector. The L3545 can be used to reliably detect even the lowest dielectric constant process materials Basic Features Separate Sensor Head and Control Unit. All control and operator adjustment functions are located in the Control Unit. The Control Unit can be mounted in a convenient and easily accessible location, up to 3000 feet away from the Sensor Head. This eliminates the need for personnel to climb high tanks, silos, bins, or enter other hazardous locations in order to make adjustments or to check instrument functionality. RF Impedance Sensing Technology with Null- Kote The L3545 uses RF impedance technology, proven in tens of thousands of applications. With no moving parts, the measurement depends solely on its modern, electronic circuitry, ensuring years of dependable operation. Heavy Duty Control Relay Two sets of Form C (DPDT) contacts are provided via a 13-position terminal block located on the printed circuit board of the L3545 Control Unit. The contacts are rated at 5 amps at 115 Vac. Sensor Flange Status Indicator The status of the process material at the sensor is indicated by the color of the SENSOR STATUS LED. The two color (red/green) LED is located on the L3545 Control Unit. Red indicates an absence of material in the pipeline; green indicates a presence. Coarse and Fine Sensitivity Adjustments Two large diameter, linearly scaled, single turn potentiometers (SENS C & F) are provided on the Control Unit board of the L3545. These adjustments are used to establish a repeatable switch point that is calibrated to the given process material application. Low-Acting Alarm Action A low alarm condition occurs when the process material is removed from the sensor (pipeline empty - absence). The alarm condition is defined as a de-energized control relay. Fail Safe Alarm Action The L3545 is in normal, non-alarmed state when it s control relay is energized (pipeline full - presence, LED green). If the L3545 were to lose power, the control relay would de-energize (LED red). Thus a power failure would produce an alarm condition alerting the operator that a problem exists. Time Delay Adjustment The L3545 senses the process material change (presence/absence) instantaneously. However, a delay can be inserted between the instant the instrument senses the change, and the time the control relay correspondingly de-energizes. A single turn TIME DELAY pot is provided on the Control Unit board of the L3545. The potentiometer allows an adjustment of 0 to 30 seconds of time delay. The time delay feature is useful to prevent momentary voids or cavities in the process material flow stream from causing the control relay to continually change state. Note that the SENSOR STATUS LED changes immediately from Green to Red, even when a delay is applied. The unit is factory-set for delay in one direction only from energized state to de-energized. Dead Band Adjustment The L3545 provides a Dead Band adjustment. A single turn DEAD BAND pot is provided on the Control Unit. The Dead Band is the band of level corresponding to the points at which the L3545 recognizes process material presence and process material absence. The dead band adjustment is used in non-conductive process material applications only. The adjustment is used primarily to compensate for minute changes in the electrical characteristics of a low dielectric constant process material. Model L3545 Instruction Manual Page 2 of 19 Rev 2, 25 July 08

6 Section One: Description Bulls Eye Indicator Lights - Optional Two lights, one red and one green, are mounted on the hinged cover of the Control Unit such that the lights are visible with the hinged cover closed and sealed. The lights provide an externally visible indication of the internal control relay status (energized-green: deenergized-red). The enclosure's NEMA rating is maintained with optional lights installed. 1.3 Sensor Flange Description Princo manufactures several types of Sensor Flanges for use with the L3515 and L3545 Presence/Absence Detectors. The electrical, chemical and physical characteristics of the process material determine the best flange for a particular application. Partial-Ring Flanges (models L632, L642, L652 and L662) are generally used for process materials that are electrically conductive. They may be used for all applications in which the pipe is 75 to 100% full under normal (safe) conditions. They are the mandatory choice for super-conductive materials such as acids, brines, or effluents and for conductive materials that tend to build up a coating on the Sensor Flange. Partial-Ring Flanges have a relatively small area of exposed stainless steel sensing element on the inside diameter of the Flange. This is desirable for conductive materials where the process material creates a virtual "short" between the sensing element and the grounded metal pipeline ground flange. Full-Ring Flanges (L631, L641, L651 and L661) are generally used for process materials that are electrically non-conductive. They are typically used to define pipe levels from 5 to 100% full. They are not suitable for super-conductive materials such as acids, brines and effluents. They may NOT be used where conductive material builds up on the Flange. Full-Ring Flanges have a stainless steel sensing element that circles the full inside diameter of the Sensor Flange. It provides maximum contact area for Figure 1-1. Typical Pipeline Installation non-conductive process materials, which are dependent upon a changing dielectric constant between the sensing element and the grounded metal pipeline or ground flange. With a Full-Ring Flange, a conductive process material would possibly create a constant contact (indicating constant presence state) between the sensor element and the ground, especially if the flange were mounted in a horizontal section of pipeline. Likewise, a Partial-Ring Flange, when used in a non-conductive application, might not produce a large enough change in RF conductivity to trigger a change of state in the controller. The standard Sensor Flanges are the L631 (Full- Ring) and the L632 (Partial-Ring). These Flanges are made from 150 lb ASTM size carbon steel flanges, with inner-diameter exposed surfaces of epoxide and 316 stainless steel. They are available in sizes of one to twelve inches. See Figure 2-1 for flange diagrams. Other Flange options include: 316 stainless steel flanges with exposed surfaces of 316 stainless steel and Teflon ; and Flanges with Tri-Clamp connectors. Flanges with inner surfaces covered by Teflon "boots" are available for applications incompatible with stainless steel and epoxide. Refer to the table in Section Two, Specifications, for a full listing of Sensor Flange models and their specifications. Refer to Princo Bulletin L-97-5 for complete dimensional details. Consult the factory for specific application questions. Model L3545 Instruction Manual Page 3 of 19 Rev 2, 25 July 08

7 Section Two: Specifications 2 Specifications 2.1 L3545 Presence Absence Detector TYPE Point type (on/off), solid state electronic, high frequency (RF), impedance sensing, remotely adjustable, Presence/Absence Detector. POWER REQUIREMENTS 95 to 135 Vac, 50 to 60Hz, 1.3 watts; or 205 to 255 Vac, 1.3 watts; or 12 to 34 Vdc, <1 watt. AMBIENT TEMPERATURE RANGE -40 to 150 F (-40 to 66 C) SENSITIVITY Senses capacitance as low as 0.15pF. Sensitivity may be decreased to approximately 1000pF. TEMPERATURE STABILITY Less than 1.0 pf typical (-40 F to +150 F). CONTROL RELAY CONTACTS Two sets of form C contacts, rated at 5 amperes, 115V ac or 26V dc, resistive load. (Two sets of form C contacts, rated at 10 amperes, 115V ac or 26V dc, resistive load for units made before June 1, 2008.) ALARM TYPE Low Acting: Alarm occurs upon absence of process material (unless otherwise specified). ALARM ACTION Fail Safe Alarm: Control relay de-energizes (drops out) upon alarm. STARTUP PUSH-BUTTON Overrides normal control function when depressed (start/prime pump). After push-button is released, override continues for a period of time equal to pre-set delay time. DELAY TIME AND DELAY MODE OPTIONS Standard delay is adjustable from 0 to 30 seconds. Standard mode is delay turn-on alarm. Consult the factory for other configurations. DEAD BAND Adjustable over range of 1.3pF for low values of process capacity. Adjustment range increases with sensitivity control setting, up to approximately 1000pF, for high values of process capacity. ELECTRONIC HOUSING CONTROL UNIT: Structural foam, thermoplastic molded base and hinged cover. Weatherproof: NEMA 1-3, 3S, 4, 4X, 12, 13. SENSOR HEAD: Heavy-duty, cast aluminum. Explosion-proof for: Class I, Div. 1 & 2, Groups C & D; Class II, Div. 1, Groups E, F & G; Class III, Div. 1 & 2. Weatherproof: NEMA 7 CD, 9 EFG. 2.2 L600 Series Sensor Flanges STANDARD FLANGE SIZES, MODELS L631 AND L632 Carbon steel, 150 lb ASTM sizes 1 to 12 inches. DESCRIPTION BY MODEL NUMBER Model Number Sensor Type Wetted Surfaces Flange Material Connection L631 Full-Ring Epoxide, 316SS Carbon Steel Flanged L632 Partial-Ring Epoxide, 316SS Carbon Steel Flanged L641 Full-Ring Teflon, 316SS 316SS Flanged L642 Partial-Ring Teflon, 316SS 316SS Flanged L651 Full-Ring Epoxide, 316SS Carbon Steel Tri-Clamp L652 Partial-Ring Epoxide, 316SS Carbon Steel Tri-Clamp L661 Full-Ring Teflon, 316SS 316SS Tri-Clamp L662 Partial-Ring Teflon, 316SS 316SS Tri-Clamp Model L3545 Instruction Manual Page 4 of 19 Rev 2, 25 July 08

8 Section Two: Specifications PRESSURE / TEMPERATURE RATINGS Model Numbers F DIMENSIONAL INFORMATION Refer to Princo Bulletin L L631*, L632*, L651*, L652* L641, L642, L661, L662 *Protect from thermal shock Figure 2-1. Typical L631 and L632 Sensor Flanges Model L3545 Instruction Manual Page 5 of 19 Rev 2, 25 July 08

9 Section Three: Installation 3 Installation 3.1 Inspection The L3545 Presence/Absence Detector is supplied with one of the Princo L600 Series Sensor Flanges. The L3545 and Sensor Flange are shipped in separate packages. Carefully remove each package s contents and check each item against the packing list. Inspect each item for shipping damage. In particular, check the springloaded connection pin, located on the threaded hub end of the Sensor Flange (see Figure 2-1). This pin provides the necessary electrical connection from the L3545 Sensor Head bottom printed circuit board, to the active element of the Sensor Flange. Make sure this pin is not missing, bent, jammed, or otherwise damaged. It should be straight, free moving and should extend about 1-1/2" from the surface of the 1- inch NPT threaded hub. Also, on the L631 and L632 Flanges, check for any cracks between the steel and epoxy surfaces. The surfaces should be mated smoothly with each other with no cracks. CAUTION! Care must be exercised when handling the Sensor Flange. Do not allow the spring-loaded pin on the Sensor Flange threaded hub to be accidentally hit or jarred on a hard surface. An accidental blow to this pin may cause poor contact with the active sensing element, on the inner surface of the sensor flange, rendering the sensor inoperable. Report any such damage immediately to the factory. Figure 3-1. L3545 with Sensor Flange: Dimensional Drawing 3.2 Mounting Partial-ring Flange (L632, L642, L652, L662) Location The most common application of L3545 presenceabsence technology is for protection of positive displacement pumps for conductive (water-based) applications. Simply put, the flange must be installed in such a position that the fluid will be touching the sensing element of the flange when the pump is to be running and not touching the sensing element when the pump is to be off. Refer to Figure 2-1 for sensing element location. It is preferred that the Sensor Flange be mounted in a vertical pipe segment as close as possible to the inlet side of the pump or other device to be protected. If the Sensor Flange is mounted in a horizontal pipe segment, it should also be located as close as possible to the inlet side of the pump or other device to be protected. The NPT connection hub on the Sensor Model L3545 Instruction Manual Page 6 of 19 Rev 2, 25 July 08

10 Section Three: Installation Flange must always be in the 12 o'clock position, as illustrated in Figures 1-1 and 3-2. Tilting the flange orientation to one side or the other risks having the pump turned on when there is only a residual amount of fluid in the pipeline. The dynamics of flow within a pipeline are often difficult to predict with any certainty. Experience has shown that certain locations may be problematic. These locations include immediately before or after a 90-degree bend (whether in a vertical or horizontal line of flow). These areas are prone in some cases to creating air pockets which turn the pump off, and in other cases to excess buildup of coating which may leave the pump on when it shouldn t be. Some locations in pipelines are likely to have air at the top even when there is steady flow. Princo recommends avoiding locations where this is possible. See Figures 3-2 through 3-7 below as examples of possible problematic locations and recommended locations. Figure 3-2. Correct Horizontal Installation (Horizontal View) Figure 3-3. Questionable Horizontal Installation (Horizontal View) Possible air in line Figure 3-4. Correct Vertical Installation (Horizontal View) Figure 3-5. Questionable Vertical Installation (Horizontal View) Possible air pockets near sensing element Figure 3-6. Correct Horizontal Installation (Vertical View) Figure 3-7. Questionable Horizontal Installation (Vertical View) Possible excessive build-up or air pockets near 90 bend Model L3545 Instruction Manual Page 7 of 19 Rev 2, 25 July 08

11 Section Three: Installation Full-ring Flange (L631, L641, L651, L661) Location Full-ring sensor flanges are used mainly for nonconductive process materials such as oils. They may safely be mounted in vertical or horizontal sections of pipeline, preferably as close as possible to the pump inlet. They do not have to be mounted at a 12 o clock orientation. Since the sensing element circles the full inside diameter of the flange, the may be set at any orientation desired. Refer to Figure 2-1 for sensing element location Full-faced Gaskets & Flanges Use a full-faced type gasket on each side of the Sensor Flange. Following these instructions will prevent product build-up around the sensing area inside the flange. NOTE The Sensor Flange is designed to mate against fullfaced gaskets and full-faced pipeline flanges. These gaskets should have an inside diameter exactly equal to the inside diameter of the pipeline in the installation. Mating against raised-face flanges and gaskets could cause cracking and improper sealing of the epoxy inner ring of the Sensor Flange. Improper gaskets may result in leakage of process material inside the flange causing the pump to run dry, as well as up into the electronic housing resulting in damage to the electronics boards Sensor Head Mounting After mounting the Sensor Flange to the pipeline, screw the L3545 Sensor Head housing onto the Sensor Flange NPT threaded hub. This is all the support it requires. NOTE Do not use any type of thread lubricant on the NPT probe mounting threads or the NPT threads that mount the electronic housing. Application of thread lubricant may cause faulty or improper ground connection. If required, Teflon tape may be used as a thread seal for either threaded connection. If Teflon tape thread sealant is used, the installer should make an electrical continuity check with a hand held ohmmeter. Continuity should exist between the metal pipeline and the Sensor Head metal housing. Less than 1-ohm resistance should exist between these two points. Refer to Figure 3-9 for ground testing points Spring-loaded Pin Make a visual check, through the Sensor Head wiring port, to verify the spring-loaded pin makes contact with the bottom printed circuit board. This may also be verified by loosening the two 8-32 mounting screws that hold the electronic chassis in the housing. The spring-loaded pin action should be felt pushing the chassis upward. If not, it may be stretched out somewhat with a pair of pliers. See figure 3-8 below. The spring-loaded pin is the electrical connection between the sensing element on the Sensor Flange and the electronic controller. Good contact is critical Grounding Figure 3-8. Spring-loaded Pin Reliable operation of the L3545 Presence/Absence Detector will only occur through proper installation. The most important installation consideration is a proper sensor ground return. If the pipeline is metal, the ground return connection is made when the sensor is properly mounted onto the pipeline. To insure proper ground connection, install a ground wire between metal pipe mounting and the ground screw on Sensor Flange as shown in Figure 3-9. If the vessel is non-metallic (i.e. plastic, or plastic lined), a separate ground return must be provided. The ground return must consist of a separate metal mounting flange, installed into the pipeline, adjacent to the Sensor Flange. A ground wire must be installed between ground screw on Sensor Flange and the ground screw on metal ground flange, as shown in Figure 3-9. Model L3545 Instruction Manual Page 8 of 19 Rev 2, 25 July 08

12 Section Three: Installation Figure A. Metal Pipe Figure B. Plastic or Plastic-lined Pipe Ground Continuity Check (Power Off) 1. Turn L3545 power off. 2. Use ohm meter on lowest scale to check following: point A (two posts) to point B - less than 1 ohm. point B to point C - less than 1 ohm. point C to point D (both ends of metal pipeline) - less than 1 ohm. point C to point E (plastic pipeline only) - less than 1 ohm. Figure 3-9. L3545 Installation and Ground Checks 3.3 Electrical Connections Control Unit Open the cover of the L3545 Control Unit in preparation for connection of input and output wires. Before drawing wires into the equipment enclosure, it may be necessary to remove the electronic circuit board chassis. To do so, unfasten the four mounting screws which are located on each corner of the pc board. Once screws are unfastened, remove the circuit board chassis by lifting it out of the instrument enclosure. Pull the power input and control relay contact wires through one of the two wiring port openings, allowing enough slack to reach the terminal block locations. Pull the Control Unit to Sensor Head cable (L3541-8, supplied with system) through the opposite wiring port opening, allowing enough slack for the individual wires to reach the terminal block locations. Replace the electronic circuit board chassis with the terminal block side of the printed circuit board facing the wiring ports. Replace mounting screws and tighten. a. Power and Control Relay Wiring For 115Vac and 230Vac powered units, connect the ac power line wires: Hot (H), Neutral (N), and Ground (G) respectively, to the left side of terminal strip (TB1) as shown in Figure If the unit requires 24Vdc for power, the terminal strip TB1 is labeled as plus (+), minus (-) and ground (G). Connect 24Vdc power to the left side of terminal strip (TB1) as shown in Figure Connect the normally open (NO), normally closed (NC) and common (C), relay wires to the terminal strip (TB1) as shown in Figure 3-10 and Figure 3-11, Model L3545 Instruction Manual Page 9 of 19 Rev 2, 25 July 08

13 Section Three: Installation and as required by the specific pump motor control circuit. Most pump control and protection applications use the normally open (NO) contacts to break power to the pump if/when the pipeline runs empty. The equipment installer should keep in mind that all L3545 units are factory set to operate in the Fail Safe LOW mode, unless otherwise specified. NOTE The relay contact configuration, shown in Figures 3-10 and 3-11, and labeled on the instrument circuit board, is identified as such with the relay in the deenergized (shelf) state. Fail-safe operation requires relay to be normally in the energized (non-shelf) state. Upon alarm, configured as either HIGH or LOW, the relay then becomes de-energized (shelf state), as per Figure 3-10, 3-11 and TB1 labeling. b. Remote Sensor Head Wiring Connect the Control Unit to Sensor Head cable (supplied with the unit) to the terminal block TB1 as shown in Figure 3-10 or 3-11: CONTROL UNIT TERMINAL (TB1) WIRE COLOR FUNCTION TB1-10 black +9.5 volt dc supply TB1-11 white sensor signal SENSOR HEAD TERMINAL (TB2) BLK WHT TB1-12 bare/clear ground BARE c. Remote Start-Up Switch Wiring Refer to Figure 3-9 or 3-10 below. Connect one end of a two-wire cable to TB1-12 and TB1-13. Connect the other end of the same cable to the terminals of a SPST, normally open, push-button switch (or equal). Depressing the switch will produce the same action as depressing the local PUMP START push-button (i.e. pump start/prime) Sensor Head Remove the lid of the L3545 Sensor Head in preparation for connection of input and output wires. Before drawing wires into the equipment housing, it may be necessary to remove the electronic circuit board chassis. To do so, unfasten the two 8-32 mounting screws which are located in the center position on the outboard sides of the electronic chassis. Once screws are unfastened, remove the circuit board chassis by pulling it out of the instrument housing. Pull the Control Unit to Sensor Head cable (L3545-8) through the wiring port opening, allowing enough slack for the individual wires to reach the terminal block locations. Connect the three cable wires; Black, White, and Bare respectively, to the terminal block (TB2) as shown in Figures 3-10 and These connections supply power to the Sensor Head from the Control Unit, and return the measurement signal from the Sensor Head to the Control Unit. Replace the electronic circuit board chassis with the flat side of the printed circuit boards facing the wiring port. Replace mounting screws and tighten. NOTE The two 8-32 mounting screws MUST be fastened securely. These two screws provide the ground connection to the printed circuit board electronics. If not fastened securely, faulty equipment operation may occur. Verify that all connections, for both the Control Unit and the Sensor Head, were made correctly. Apply power to the Control Unit, and allow 10 minutes before making required calibration adjustments. Model L3545 Instruction Manual Page 10 of 19 Rev 2, 25 July 08

14 Section Three: Installation Figure Electrical Connections 115Vac & 230Vac Units Figure Electrical Connections 24Vdc Units Model L3545 Instruction Manual Page 11 of 19 Rev 2, 25 July 08

15 Section Three: Installation 3.4 Installation in Hazardous Areas The outline which follows points out some of the major requirements of the NEC's (National Electric Code) Section 501, as it relates to typical level control installations. WARNING! The Princo Model L3545 Level Control is not to be considered an explosion-proof instrument. The instrument does not incorporate an enclosure that would allow for the appropriate explosion-proof approval rating (see above Section 2 for NEMA ratings). For all applications, it is the customer's responsibility to install the required conduit, seals, wiring, etc., which meet national, as well as applicable local and plant safety codes. See Figure 3-12 below. For Class 1 locations, rigid metal conduit must be used. At least five full threads of the conduit must be tightly engaged in the enclosure. Conduit seal fittings must also be used. These seal fittings, must be filled with an approved sealing compound and must be installed within 18 inches (or closer) of the enclosure. Conduit seals are also required when the conduit passes from a hazardous area into a non-hazardous area. Water drain seal fittings eliminate or minimize the effect of water that tends to collect in the conduit or enclosure due to condensation. Approved wire type, such as mineral-insulated wire, is required for use in Division 1 installations. Certain types of metal-clad cable or shielded non-metallic sheathed cable are permitted in Division 2 installations. When multi-conductor cables are used in the conduit, the outer jacket must be cut away in such a manner that allows the sealing compound to surround each insulated wire as well as the jacket. The preceding information should act as guide to assist the customer/installer in satisfying their responsibility for producing safe installations in hazardous area. Figure L3545 Electrical Installation Model L3545 Instruction Manual Page 12 of 19 Rev 2, 25 July 08

16 Section Four: Adjustments and Operation 4 Adjustments and Operation 4.1 Initial Checkout 1. Refer to Figure 4-1 for L3545 adjustment and indicator locations. 2. Install the L3545 Level Controller with Sensor Flange as presented in Section 3 of this manual. 3. Apply power to the unit and allow a 15-minute warm-up time before performing the calibration procedure as outlined below. 4. Perform Section Basic Electronic Checks. Figure 4-1. L3545 Adjustment and Indicator Locations 4.2 Calibration The Coarse (C) and Fine (F) sensitivity (SENS) pots must be properly adjusted in order to establish a repeatable switch point for the given process material. NOTE Two adjustment procedures are listed below one for conductive processes and one for non-conductive processes. Water-based processes will generally be conductive. However, conductive processes that leave a thick coating inside the pipeline may approximate the conditions of a non-conductive process and require the use of the non-conductive procedure Adjustment Procedure - Conductive Process Materials a ) Refer to Figure 4-1 for adjustment and indicator locations. Refer to figure 4-2 for a pictorial outline of this procedure. b ) Allow the unit to warm up (thermally stabilize) for approximately 15 minutes before proceeding with steps c through i below. c ) Preset Coarse (C) and Fine (F) sensitivity (SENS) potentiometers to mid-point positions (12 o'clock). d ) Turn the TIME DELAY and DEAD BAND pots to the fully counter-clockwise position (no delay, minimum dead band). e ) Pre-coat the Sensor Flange by filling and then emptying the pipeline with the product that normally flows through the pipeline. f ) With the pipeline and Sensor Flange completely empty (coated from step e), adjust the Coarse (C) sensitivity such that the SENSOR STATUS LED "just turns" green. Mark the Coarse (C) pot screwdriver slot or mentally note its position. Model L3545 Instruction Manual Page 13 of 19 Rev 2, 25 July 08

17 Section Four: Adjustments and Operation NOTE Clockwise rotation increases sensitivity for both Coarse and Fine potentiometers. g ) Fill the pipeline and Sensor Flange with the product that normally flows through the pipeline. h ) Adjust the Coarse (C) sensitivity pot counterclockwise such that the SENSOR STATUS LED "just turns" red. Mark or mentally note position of screwdriver slot. i ) Adjust the Coarse (C) sensitivity pot until the screwdriver slot is midway between the marks from steps f and h. The SENSOR STATUS LED should now be green (Sensor Flange and pipeline filled with product from step g). If not repeat steps a through i. NOTE A green SENSOR STATUS indicator denotes presence of material in the Sensor Flange, and a red indicator denotes absence of material in the Sensor Flange, when sensitivity potentiometers are properly adjusted. Figure 4-2. Conductive Process Calibration Procedure Model L3545 Instruction Manual Page 14 of 19 Rev 2, 25 July 08

18 Section Four: Adjustments and Operation Figure 4-3. Non-Conductive Process Calibration Procedure Model L3545 Instruction Manual Page 15 of 19 Rev 2, 25 July 08

19 Section Four: Adjustments and Operation Adjustment Procedure Nonconductive (Insulating) Process Materials a ) Refer to Figure 4-1 for adjustment and indicator locations. Refer to Figure 4-3 for a pictorial outline of this procedure. b ) Allow the unit to warm up (thermally stabilize) for approximately 15 minutes before proceeding with steps c through j below. c ) Preset the Fine Sensitivity pot (F) full clockwise and the Coarse Sensitivity pot (C) to the full counter-clockwise position. d ) Turn the TIME DELAY and DEAD BAND pots to the fully counter-clockwise position (no delay, minimum dead band). e ) Pre-coat the Sensor Flange by filling and then emptying the pipeline with the product that normally flows through the pipeline. f ) With the pipeline and Sensor Flange completely empty (coated from step e), adjust the Coarse (C) sensitivity potentiometer such that the SENSOR STATUS LED "just turns" green, and stays. Don't touch the Coarse (C) sensitivity pot again. NOTE Clockwise rotation increases sensitivity for both Coarse and Fine potentiometers. g ) Adjust the Fine (F) sensitivity potentiometer counter-clockwise, such that the SENSOR STATUS LED "just turns" red and then back clockwise until it "just turns" green. Mark the position of the Fine (F) sensitivity pot. h ) Fill the pipeline and Sensor Flange with the product that normally flows through the pipeline. i ) Adjust the Fine (F) sensitivity pot counterclockwise, such that the SENSOR STATUS LED "just turns" red and stays. Mark or mentally note position of screwdriver slot. j ) Adjust the Fine (F) sensitivity pot until the screwdriver slot is midway between the marks from steps g and i. The SENSOR STATUS LED should now be green (Sensor Flange and pipeline filled with product from step h). If not repeat steps a through j. If this procedure exceeds the span of the Fine (F) pot, use the procedure for conductive materials Section NOTE A green SENSOR STATUS indicator denotes presence of material in the Sensor Flange, and a red indicator denotes absence of material in the Sensor Flange, when sensitivity potentiometers are properly adjusted. 4.3 Alarm Action The L3545 is in the normal non-alarmed state when its control relay is energized. The unit is in the alarm state when its internal control relay is deenergized. Hence, if the unit lost power, the internal control relay would de-energize, and an alarm condition would occur. This type of Fail-Safe operation is based on the fact that most major malfunctions, including a power failure, would cause the control relay to de-energize. 1. Fail-Safe Low Operation (Low Acting Alarm): The control relay contacts de-energize (shelf state) upon Low Alarm. When process material absence is detected, a Low Alarm condition occurs, and the relay changes from the normal non-alarmed (energized) state to the alarmed (de-energized) state. Unless otherwise indicated, the L3545 has been factory set for Fail Safe Low operation. Consult the factory if change to Fail Safe High operation is required. 4.4 Delay Operations and Adjustments Time delay is useful in preventing control relay "chatter" caused by momentary pockets of air or voids in the product flow stream as it passes through the Sensor Flange. The three types of time delay are as follows: delayed turn-on alarm, delayed turn-off alarm, and delayed turn-on alarm/turn-off alarm. The L3545 is normally configured at the factory for delayed turn-on alarm mode. A single turn TIME DELAY pot is provided (see Figure 4-1). Many applications require no time delay. In this case, adjust the TIME DELAY pot to the maximum counter-clockwise direction (zero time delay). If Time Delay is required, start by adjusting the TIME DELAY pot to approximately 30 percent of its full CW rotation (about 10 seconds). Determine the optimal setting through trial and error. The maximum standard delay time is 30 seconds full scale. Consult factory for optional delays. Model L3545 Instruction Manual Page 16 of 19 Rev 2, 25 July 08

20 Section Four: Adjustments and Operation 4.5 Dead Band Adjustment A given dead band adjustment represents a certain physical distance on the active sensor element over which the process material has to move in order for the L3545 to change from a non-alarm to an alarm condition, and vice versa. The dead band adjustment is used in non-conductive process material applications only. The adjustment is used primarily to compensate for minute changes in the electrical characteristics of a low dielectric constant process material. The physical distance on the active sensing element of this band, for a given dead band adjustment, is greater for less responsive process materials (i.e. low dielectric constant process materials) than it is for high response process materials (i.e. high dielectric constant, or conductive process materials). When the DEAD BAND pot is turned clockwise, the trip point opens up into an ever-increasing band, above and below the original set point. The control relay would energize at the top point, and de-energize at the bottom point. Accordingly, adjust the Dead Band pot clockwise (see Figure 4-1) just enough to compensate for the adverse process effect in question (i.e. minute electrical conductivity changes in the product flowing in pipeline). Note that the action of the Dead Band adjustment will be defeated in applications where the process liquid is conductive. 4.6 Start Pump Push-button The START PUMP push-button is used to start a pump when the pipeline is empty. Pushing the START PUMP push-button overrides the normal Low Alarm condition (energizes relays) and turns on the pump. The pump will stay on as long as the push-button is held. It will also stay on after the push-button is released for the duration of a pre-set Time Delay. Once process material contacts the Sensor Flange sensing element, the pump will remain on because of the normal control action of the system. Action of a remotely wired push-button (see Section c) is the same as that of the front panel push-button. Model L3545 Instruction Manual Page 17 of 19 Rev 2, 25 July 08

21 Section Five: Equipment Service 5 Equipment Service 5.1 Trouble-Shooting Guide Basic Electronic Checks 1. Basic Electronic Checks The PROBE STATUS LED should be lit to either red or green at all times. If not, check that proper power is applied to the Power terminals. With both the Coarse (C) and Fine (F) sensitivity potentiometers turned fully clockwise, the PROBE STATUS LED should be green. With both potentiometers turned fully counterclockwise the LED should be red. The PROBE STATUS LED should switch crisply from green to red or from red to green. It should never hang in between in an orange color. If the unit fails any of the above checks, return the L3545 electronic chassis to the factory for repair or replacement Adjustment Problems After performing the adjustment procedure, the unit fails to shut off or on properly. Check ground continuity (refer to Figure 3-9). Check that the spring-loaded pin on the Sensor Flange is making contact with the silver pad on the bottom of the electronic circuit board. Refer to Figure 3-8. The pin normally projects about 1- ¼ inches above the NPT fitting on the flange. It may be stretched out further with a pair of pliers without causing damage. Be sure that full and empty pipeline conditions really exist when performing the adjustment procedure. It may be necessary to drain the pipeline to remove residual material before performing the empty adjustment. Check for the presence of process fluid in the Sensor Flange hub and in the housing of the L3545 Sensor Head. Leakage of fluid from the pipeline into the hub could produce a constant "presence" condition. If this condition exists, the Sensor Flange is defective and should be returned to the factory for repair or replacement. Likewise, if there is evidence that the electronic circuit boards have been flooded, they should be sent to the factory for testing, and repair as necessary. NOTE When performing the adjustment procedure, there should be a noticeable change in the position of the Coarse (C) Sensitivity potentiometer for conductive processes and in the position of the Fine (F) Sensitivity potentiometer for non-conductive processes between the empty and full adjustment points. If there is not, the electronic unit is not sensing any change, probably due to one of the above conditions. Typically, for conductive processes, the switch point for the Coarse pot for absence will be between 1 and 3 o clock, and for presence between 9 and 11 o clock. In other words, when going from absence to presence, the switch point will shift in the counterclockwise direction. Unit switches correctly once or several times and then fails to switch correctly. A progressively thicker coating may be building up inside the pipeline. This would result in a narrower span between the empty and full positions of the Sensitivity potentiometer when performing the adjustment procedure. Solution: This condition will require performing the adjustment procedure over again when the coating is at its thickest point. There may have been a change in the dielectric constant of the process material. This would change the flow of RF current through the sensor, effectively shifting the switch point. Solution: RF impedance technology is designed to operate with materials having a constant dielectric constant (therefore, a constant RF conductivity). It may be possible, through trial and error, to find a switch point that works for some changes in dielectric constant; but extreme changes, like oil to water, may be impossible to compensate for. Generally speaking, a unit adjusted for a low dielectric constant material will switch correctly for a higher dielectric constant material or for a conductive material. However, this could be negated by changes in the coating characteristics. 3. Problem Analysis The connection points for the 3-wire cable connecting the L3545 Control Unit to its Sensor Head are convenient for troubleshooting purposes using a DC voltmeter. a) Power Supply Check Place the negative lead of the voltmeter on TB1-12 of the Control unit (bare wire - ground). Place the Model L3545 Instruction Manual Page 18 of 19 Rev 2, 25 July 08

22 Section Five: Equipment Service positive lead on TB1-10 (black wire Vdc supply). Meter should read +9.5 Vdc +/ Vdc. A low reading could indicate low power line voltage, failure in the electronic circuitry, a short in the 3-wire cable or a ground loop in the wiring. To test for ground loop, remove ground wire from TB1-12. With voltmeter still on TB1-12 and TB1-10, see if reading rises to 9.5 Vdc. If it does, there is a short or a ground loop in the cable or the L3545 Sensor Head. If voltage remains low, the problem is in the L3545 Control Unit. b) Sensor Head / Sensor Flange Check If +9.5 Vdc is present per step a, place negative voltmeter lead on TB1-12 (bare wire - ground) and the positive lead on TB1-11 (white wire - signal). A dc voltage should be present. The level of this voltage is inversely proportional to the RF conductivity between the sensor flange sensing element and the ground reference. There should be a noticeable change in this voltage between the empty and full pipeline conditions. Actual voltages will vary depending on pipeline geometry, process material conductivity or dielectric constant and the thickness of the coating. A typical voltage change for a water-based process might be 4.0 Vdc dry and 0.5 Vdc wet. The difference in voltage will be less for non-conductive processes and conductive processes with heavy coatings. If this change is present, Sensor Head and Sensor Flange are functioning correctly. If the voltage level is not changing and is extremely high or low (9.5 V or 0.0 V), there could be a short in the Sensor Head or in the wiring. If a reasonable voltage is present (for example, 2.5 V) but not changing, it is possible that the condition inside the pipeline is not changing. A constant high voltage (about 4.5 V) could indicate that the spring-loaded pin on top of the Sensor Flange is not contacting the bottom of the Sensor Head circuit board or a failure of the process material inside the pipeline to contact the Sensor Flange sensing element. A constant low voltage ( 0.5V) could indicate a constant presence condition inside the pipeline. It could also indicate the presence of fluid on the Sensor Flange hub, shorting the spring-loaded pin to ground. the closest Princo sales representative in your area, or call the factory direct and ask for service assistance. The factory telephone number is To assist us in providing an efficient solution to the particular problem, please have the following information available when you call: 1. Instrument model number 2. Probe model number 3. Purchase order number 4. Date of purchase order 5. Process material being monitored 6. Detailed description of the problem If your equipment problem cannot be resolved over the phone, then it may be necessary to return the equipment for checkout/repair. Do not return equipment without first contacting the factory for a Return Material Authorization number (RMA #). Any equipment that is returned MUST include the following information in addition to the list above. 7. RMA number 8. Person to contact at your company 9. Return (ship to) address Princo level instruments are covered by a 10-year limited warranty. You will not be charged if it is determined that the problem is covered under warranty. Please return your equipment with freight charges prepaid. If repair is covered under warranty, Princo will pay return freight charges. If telephone assistance or equipment return is not a practical solution to the problem, then it may be necessary for field assistance. Trained field service technicians are available from the factory on a time/expense basis to assist in these instances. 5.3 Warranty Statement All Princo level control instruments are backed by a 10-year warranty. Princo will repair or replace, at its option, any instrument that fails under normal use for up to 10 years after purchase. 5.2 Getting Help If your Princo equipment is not functioning properly, and attempts to solve the problem have failed, contact Model L3545 Instruction Manual Page 19 of 19 Rev 2, 25 July 08

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

PRO REMOTE Series CAPACITANCE PROBE

PRO REMOTE Series CAPACITANCE PROBE Price $5.00 PRO REMOTE Series CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4

More information

PRO REMOTE 25 LV CAPACITANCE PROBE

PRO REMOTE 25 LV CAPACITANCE PROBE Price $5.00 PRO REMOTE 25 LV CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26

More information

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0330 Rev 0 0416 TABLE OF CONTENTS SAFETY SUMMARY... 3 SPECIFICATIONS... 4 1.0 INTRODUCTION/DESCRIPTION.... 5 2.0 LOCATION AND MOUNTING... 5 3.0 CONNECTIONS

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low fail-safe

More information

Ultrasonic Two-Wire Point Level Control

Ultrasonic Two-Wire Point Level Control Ultrasonic Two-Wire Point Level Control General Instructions The Ultrasonic Point Level Control indicates liquid presence/absence within a sensor cavity. Two piezoelectric crystals face each other across

More information

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE MEMBER GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA 01001-2907, USA LSM672 LOAD SHARING MODULE PRODUCT TECHNICAL INFORMATION PTI 4000 AUGUST

More information

PROCAP Capacitance Level Sensors

PROCAP Capacitance Level Sensors PROCAP Capacitance Level Sensors Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low

More information

PRODUCT INFORMATION BULLETIN

PRODUCT INFORMATION BULLETIN 724-283-4681 724-283-5939 (fax) PRODUCT INFORMATION BULLETIN DESCRIPTION The, Model 10-7100 is one in a series of critical speed switches that monitor speed and detect motion in all types of machinery

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

Shock/Vibration Control Switches

Shock/Vibration Control Switches Shock/Vibration Control Switches Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 ` Installation Instructions 00-02-0185 2013-02-01 Section 20 Please read the following information before installing.

More information

RF Point Level Control with Sensor Monitor

RF Point Level Control with Sensor Monitor The 681 Point Level Control utilizes DPDT relays to provide switching for peripheral devices (such as pumps) in level applications. A sensor attached to the control acts as an antenna to transmit the process

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor

Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor Ultrasonic Two-Wire Point Level Control with Tip-Type Sensor General Instructions The Ultrasonic Point Level Control produces an 8mA or l6ma current to indicate liquid presence/absence within a sensor

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service Installation Instructions VA-908x Code No. LIT-12011566 Issued August 24, 2009 Applications The VA-908x Series Electric

More information

Dynaweb, Inc. EP350 Dancer Tension Controller. Instruction Manual

Dynaweb, Inc. EP350 Dancer Tension Controller. Instruction Manual Dynaweb, Inc. EP350 Dancer Tension Controller Instruction Manual 1 DYNAWEB, INC July 1, 2010 Page# INSTALLATION 2 START-UP, POWER OFF, NO WEB 2 START-UP, POWER ON, NO WEB 3 START-UP, POWER ON, WEB UP MACHINE

More information

ITS-50R TRANSFER SWITCH OWNER S MANUAL

ITS-50R TRANSFER SWITCH OWNER S MANUAL ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard

More information

ELECTRICAL. Contents - Wiring Diagrams

ELECTRICAL. Contents - Wiring Diagrams Contents - Wiring Diagrams T-Bar (Floating Deck - Hydro)............................................ 8-16 T-Bar (Fixed Deck - Gear)............................................... 8-17 T-Bar (Fixed Deck

More information

Transfer Switch GPTS 30

Transfer Switch GPTS 30 Transfer Switch GPTS 30 Owner s Manual Table of Contents Introduction 2 Installation 3 Operational Testing 7 Troubleshooting 8 Hi-Pot Testing 9 Generator Note 10 Medical Appliances 10 Caution 10 Warranty

More information

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual Electronic Motor Brake Type G Instructions and Setup Manual Table of Contents Table of Contents Electronic Motor Brake Type G... 1 1. INTRODUCTION... 2 2. DESCRIPTION AND APPLICATIONS... 2 3. SAFETY NOTES...

More information

Installation and Operating Manual

Installation and Operating Manual Model u002 & u003 Installation and Operating Manual Ultrasonic Level Switch 60 Great Hill Road Naugatuck, CT 06770 ph: 203-729-6434 fax: 203-729-6696 www.innovativesensing.com Read this Manual Before Installing

More information

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE SENS part number: 101037 Document revision: A Engineering change number: 105073 Date: 1/13/2006 1840 Industrial Circle

More information

System 350 S350P Proportional Plus Integral Temperature Stage Module

System 350 S350P Proportional Plus Integral Temperature Stage Module FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,

More information

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS HVAC/BAC ELECTRIC IOM ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS Electric Actuator Specifications... 2 Overview... 3 Actuator

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

Transfer Switch TS-50. Owner s Manual

Transfer Switch TS-50. Owner s Manual Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer

More information

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual IOM LP-100 & LP-200 Pulse Point TM Installation & Operation Manual CAUTION It is essential that all instructions in this manual be followed precisely to ensure proper operation of the equipment. SAFETY

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the actuator out. If it rotates

More information

E.S.P. Embedded Sensing Probes for Motor Brushes

E.S.P. Embedded Sensing Probes for Motor Brushes E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1 OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1 This instruction manual contains important information regarding the installation, operation, and troubleshooting of

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

M100F Incremental Motor Actuator R81F Interface Board

M100F Incremental Motor Actuator R81F Interface Board Installation Sheets Manual 121 Motor Actuators Section M Technical Bulletin M100F Issue Date 0493 M100F Incremental Motor Actuator R81F Interface Board Application Details Figure 1: M100 Motor Actuator

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

100 Series Flow Switches Technical Reference Manual

100 Series Flow Switches Technical Reference Manual Proteus Industries Inc. 100 Series Flow Switches Technical Reference Manual Can we Improve? Tell our President! Can we improve our product, our support or this manual? We are committed to continuous improvement

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions Figure 1. T5420 Outline Dimensions. INSTALLATION The Model T5420 can be mounted directly onto a flat surface

More information

RP-4000 Reserve Power Control

RP-4000 Reserve Power Control Instruction Manual IM-0580 RP-4000 Reserve Power Control Table of Contents General Information... 2-3 Introduction... 2 Cautions... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Identification

More information

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS CABINET REEL OPERATING INSTRUCTIONS MODELS 15, 25, 40 & 60 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com

More information

ENGINE GOVERNING SYSTEMS

ENGINE GOVERNING SYSTEMS ENGINE GOVERNING SYSTEMS ESD5400 Series Speed Control Unit INSTALLATION The speed control unit is rugged enough to be placed in a control cabinet or engine mounted enclosure with other dedicated control

More information

KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail: info@kenco-eng.com SERIES KTD THERMAL DIFFERENTIAL FLOW/LEVEL SWITCH INSTALLATION

More information

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED*

Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 GENERAL INFORMATION LISTED* Shock/Vibration Control Switches Installation Instructions Models: VS2, VS2C, VS2EX, VS2EXR, VS2EXRB and VS94 VS-7037N Revised 04-05 Section 20 (00-02-0185) Please read the following instructions before

More information

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL TABLE OF CONTENTS SYSTEM...... Warning........ Description...... Prior to Operation OPERATION... Main Components... Mechanical...

More information

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Your Global Flow Control Partner Series 70 Table of Contents 1. Definition of Terms.......................................2 2. Safety............................................. 2 3. Storage............................................2

More information

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual Series 70 Operation and Maintenance Manual TABLE OF CONTENTS 1. Definition of Terms............................................. 1 2. Safety................................................... 1 3. Storage..................................................

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

Installation Instructions

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its failsafe position. If the shaft rotates counterclockwise, mount the CCW side of the

More information

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual Model 1017-07 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0480 Revision: P1 Released: 1/4/19 www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

BMRX Series Rotary Level Indicator

BMRX Series Rotary Level Indicator BMRX Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

DC Variable Speed Drive Panel

DC Variable Speed Drive Panel DC Variable Speed Drive Panel Installation, Operation & Maintenance Instruction Manual Bulletin #: CC-IOM-0103-D Manufacturers of Quality Pumps, Controls and Systems ENGINEERED PUMP OPERATIONS 2883 Brighton

More information

MODEL 905V OPERATING INSTRUCTIONS

MODEL 905V OPERATING INSTRUCTIONS MODEL 905V OPERATING INSTRUCTIONS Quantek Instruments 183 Magill Drive Grafton, MA 01519 Tel: (508) 839-3940 Fax: (508) 819-3444 Email: sales@quantekinstruments.com GENERAL DESCRIPTION These instructions

More information

Installation Operation Maintenance ADDENDUM

Installation Operation Maintenance ADDENDUM Installation Operation Maintenance ADDENDUM Bulletin #: PS-IOM-HYPO2-0111-A FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting

More information

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION CONVEYOR COMPONENTS COMPANY 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com http://www.conveyorcomponents.com

More information

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation 12 Series Linear Actuators Operation & Maintenance Manual, Analog Positioner Installation 6810 POWERLINE DR.-FLORENCE, KY. 41042 - TELEPHONE 859-727-7890, TOLL FREE 1-800-662-9424 FAX. 859-727-4070, E-MAIL:

More information

Valtek Auxiliary Handwheels and Limit Stops

Valtek Auxiliary Handwheels and Limit Stops Valtek Auxiliary s and Limit Stops Table of Contents Page 1 General information 2 Installation 2 Side-mounted handwheels, size 25 and 50 (linear actuators) 3 Side-mounted handwheels, size 100 and 200 (linear

More information

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for

More information

CONTROL FEATURES AVAILABLE OPTIONS

CONTROL FEATURES AVAILABLE OPTIONS Vari Speed A2000 TABLE OF CONTENTS Control Features Options Application Data Operating Condition s Control Ratings Chart Mounting Dimensions Installation and Wiring Typical Wiring Diagram Schematic (Block

More information

E Series CE Approved Intermittent Pilot Ignition Control

E Series CE Approved Intermittent Pilot Ignition Control Installation Instructions Issue Date January 11, 2013 E Series CE Approved Intermittent Pilot Ignition Control Application The E Series CE Approved Intermittent Pilot Ignition Control is a safety control

More information

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch.

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch. DREXELBROOK DATA SHEET Easy-Installation One-piece unit is easily installed through a single 3/4-inch, probe dependent vessel opening. Calibration is quick and simple. Z-tron IV Point Level Switch, a reliable

More information

HI-POT/CONTINUITY TESTER Model PLEP01

HI-POT/CONTINUITY TESTER Model PLEP01 HI-POT/CONTINUITY TESTER Model PLEP01 Instruction Manual MITCHELL INSTRUMENT CO. Dear Customer: Congratulations! Mitchell Instrument Co. is please to present you with your Hipot/Continuity Tester. This

More information

PMV P36C AND P41C POSITIONERS ACTUATORS

PMV P36C AND P41C POSITIONERS ACTUATORS PMV P36C AND P41C POSITIONERS USED WITH DeZURIK PNEUMATIC ACTUATORS Instruction D10327 August 2012 Instructions These instructions provide information about Models P36C and P41C PMV Positioners. They are

More information

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners. INSTALLATION & OPERATING INSTRUCTIONS SERIES 40 Positioners Form IO2-0406 Description of Device Moniteur's Series 40 pneumatic (3-15psi) and electropneumatic (4-20mA) positioners are advanced control devices

More information

LIPPERTCOMPONENTS, INC.

LIPPERTCOMPONENTS, INC. LIPPERTCOMPONENTS, INC. SCHWINTEK INWALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL Contents I. Controls 1-1 System components 1 1-1A versions C1 & C2 2 1-2 Motor wiring harness connections 3 1-3 Extend

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

Model Combustible Gas Sample Draw Detector Head Operator s Manual

Model Combustible Gas Sample Draw Detector Head Operator s Manual Model 1017-06 Combustible Gas Sample Draw Detector Head Operator s Manual Part Number: 71-0356 Revision: P1 Released: 2/4/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

A Methane Sample-Draw Detector Operator s Manual

A Methane Sample-Draw Detector Operator s Manual 35-3001A-01-01 Methane Sample-Draw Detector Operator s Manual Part Number: 71-0310RK Revision: A Released: 8/7/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual Mechanical Specifications Flow Meter with Polypropylene Body (ES version) Maximum Operating Pressure: 150 PSIG Maximum

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions

More information

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators Setting the Standard in Mobile Power Instruction Manual for Model HYDRO ARC-S-6500 JSBC Hydraulic Generator Welder Manufacturing of: Vehicle Mounted Generators Hydraulic Generators P.O. Box 582 Chester,

More information

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...5 2.1 Location and

More information

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example Top Quality Valve Actuators Made in Sweden Twin Power Manual Pneumatic Multiturn actuator in Standard and ATEX design Mounting The Twin Power actuator works beyond reproach in all positions. Valves with

More information

BMRX Series ROTARY LEVEL CONTROL

BMRX Series ROTARY LEVEL CONTROL BMRX Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0292 Rev C TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY... 4 1.0 INTRODUCTION... 5 2.0 INSTALLATION...

More information

Electric Actuator Instructions

Electric Actuator Instructions BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5

More information

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1 Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]

More information

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE

SmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF

More information

TRAC-3 TENSION READOUT AND CONTROL

TRAC-3 TENSION READOUT AND CONTROL Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL TRAC-3 READOUT AND CONTROL For Control of Magnetic Particle

More information

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION EMP-5 Installation Manual - P/N 80103 - Ed. 01/09 EMP-5 Current or Voltage Input Drive Modulating Actuator Installation Instructions 1 7 SPECIFICATIONS The EMP-5 series actuators provide damper control

More information

MAXIGARD A2000 SPEED SWITCH. Introduction

MAXIGARD A2000 SPEED SWITCH. Introduction A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor

More information

G76x Direct Spark Ignition Controls

G76x Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition

More information

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT INSTALLATION AND WIRING INSTRUCTIONS MANUAL 8030 MANUAL PART NUMBER JANUARY 2011. 4304 MATTOX RD. KANSAS CITY, MO 64150 TABLE OF CONTENTS

More information

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Flowline, Inc. 10500 Humbolt Street Los Alamitos, CA 90720 Tel: (562) 598-3015

More information

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual COMPANY Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual 2016 AW-Lake Company. All rights reserved. Doc ID:PADDLEMAN082416 Mechanical Specifications Flow Meter with Polypropylene

More information

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS ELECTRIC ACTUATOR E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS 94OE IOM Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4

More information

Quarter Master Chief Series 92 Actuator

Quarter Master Chief Series 92 Actuator Quarter Master Chief Series 92 Actuator Installation, Operation and Maintenance Manual File: Series 92 O & M manual Rev. V 4/22/2013 Page 1 of 13 Table of Contents Series 92 Electric Actuator Introduction...

More information

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317) 715B CONTROL SERIES CONTROLS Instruction Manual Line Voltage DC Brushless Motor Control LT715B (IM-715B-0100) P.O. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873-1105

More information

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls P-269-89-0408 Installation Installation & Operating Instructions Contents Introduction........................... 2 Specifications.........................

More information

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation DODGE ENGINEERING & CONTROLS, INC. 196 Riverneck Road Chelmsford, MA 01824 PHONE (978) 244-1200 FAX (978) 244-1422 TOLL FREE (877) 334-2875 RE Generation II Troubleshooting Guide Section I Preliminary

More information

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-BFV.KIT Butterfly Valve Gear Operator Replacement SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before

More information

CP-1TT Remote System

CP-1TT Remote System CP-1TT Remote System (9 volt & 12 volt systems) INSTALLATION/OPERATION MANUAL Manufactured by: Preferred Technologies Group www.cartell.com TABLE OF CONTENTS This Table of Contents is clickable. Point

More information

Super-Safe-Plus Roto-Bin-Dicator

Super-Safe-Plus Roto-Bin-Dicator Super-Safe-Plus Roto-Bin-Dicator for your most demanding applications... Offers both mechanical and electronic sensing in one reliable Point Level Sensor... Level control with added confidence Under normal

More information

PROVEX Installation Guide. Version 1.0

PROVEX Installation Guide. Version 1.0 Version 1.0 INTRODUCTION The scale must not be loaded beyond its capacity. Do not select a site where overweight load would have to maneuver to avoid crossing the platform. Avoid areas where the scale

More information