TW...series ball valve Wisdom series DN15~DN50 Female threaded connection for PN25 DN40~DN150 Flanged connection for PN16/PN25
|
|
- Dennis Ellis
- 5 years ago
- Views:
Transcription
1 Rev.H TW...series ball valve Wisdom series D15~D50 threaded connection for P25 D40~D150 Flanged connection for P16/P25 Features Introduction RS485 Remote Control The actuator is equipped with RS485 communication interface. The valve can be remotely controlled by ModBus protocol. FC (ear Field Communication) The actuator has FC function which can not only control opening and closing of valve by mobile FC client, but also set a number of parameters. FC function can still read actuator parameter even if the actuator is powered off on site. V Shape Ball Core Adopts V shape ball core design, with perfect regulation curve. Adjustable ratio >100.Ball core adopts stainless steel material,compared with brass ball core, it will be better correction resistance and longer lifetime. Speed Adjustability The high/low speed can be switched through Dip swich. High speed 30s/90, low speed 60s/90. Manual Function The actuator has the mechanical manual function and manual priority function, that is, when insert the wrench, the actuator will be automatically powered off which is safe and convinent. Mistake-proofing Interface The interface of valve body and actuator adopts mistake proofing design, which can avoid disassembling and adjusting repeatedly caused by installation error. ocal Mode (Electric manual function) The actuator has local control function which can control the opening and closing of valve by the button on the plate. ED Indicating ight There are ED indicating lights on the actuator cover which is convenient to observe the actuator running status. Tiger Controls Equipment Co., td 1
2 Type Summary Kv 2-port Ball Valve with port plate Caliber [in.] Connection Kvs [m 3 /h] Actuator Type Actuator Power Torque [.M] Ps [MPa] TB15-2VTD-BX 1/2" 15 4 Open TB20-2VTD-BX 3/4" TB25-2VTD-BX 1" TB32-2VTD-BX 1 1/4" TB40-2VTD-BX 1 1/2" TW15M-BX24 TW15M-BX TB50-2VTD-BX 2" TW15M-BX24 TW15M-BX TBF40-2VGC-BX 1 1/2" 40 Flanged 38 TW20M-BX24 TW20M-BX TBF50-2VGC-BX 2" 50 Flanged 73 TW20M-BX24 TW20M-BX TBF65-2VGC-BX 2 1/2" 65 Flanged 110 TW20M-BX24 TW20M-BX TBF80-2VGC-BX 3" 80 Flanged 160 TW20M-BX24 TW20M-BX TBF100-2VGC-BX 4" 100 Flanged 220 TW50M-BX24 TW50M-BX TBF125-2VGC-BX 5" 125 Flanged 330 TW50M-BX24 TW50M-BX TBF150-2VGC-BX 6" 150 Flanged 418 TW50M-BX24 TW50M-BX Kv 2-port Ball Valve without port plate Caliber [in.] Connection Kvs [m 3 /h] Actuator Type Actuator Power Torque [.M] Ps [MPa] TB15-2VTD-BD 1/2" 15 4 Open TB20-2VTD-BD 3/4" TB25-2VTD-BD 1" TB32-2VTD-BD 1 1/4" TB40-2VTD-BD 1 1/2" TW15M-BX24 TW15M-BX TB50-2VTD-BD 2" TW15M-BX24 TW15M-BX Relationship between Differential Pressure and Flow Kvs P: Differentia pressure when valve is full open(unit:kpa) V: Rating flow at the P (unit: m 3 /h) Kvs: orminal flow coefficient, which refer to the flow when medium (Density=1g/cm 3 ) go through the full open control valve,whose P is 100KPa. Tiger Controls Equipment Co.,td 2
3 DIP Switch Instruction Switch Function Description -1 Starting of control/ 20%:the starting of control/feedback signal is 20%(namely 4~20mA or 2~10VDC) feedback signal 0:the starting of control/feedback signal is 0(namely 0~20mA or 0~10VDC) -2 Type of control signal -3 Impedence match of control signal -4 Type of feedback signal -5 Operating mode -6 osing control signal mode II:current signal UI:voltage signal UI:voltage signal II:current signal IO:current signal UO:voltage signal DA:when the control signal increases, actuator runs to 1 ; when the control signal decreases, actuator runs to 0 RA:when the control signal increases, actuator runs to 0 ; when the control signal decreases, actuator runs to 1 DW: when lose control signal (voltage type), actuator will provide a min. control signal internally. when lose control signal (current type), actuator will provide a min. control signal internally. UP: 1)when lose control signal (voltage type), actuator will provide a max. control signal internally. 2)when lose control signal (current type), actuator will provide a min. control signal internally. -7 Self-stroking mode DF:Power on each time, self-stroking starts automatically. -8 Control mode (when -9 is ) 3-position type Proportional type RF:Self-stroking starts only when press the self-stroking buttom manually. -9 Control type RS485 interface control(modbus protocol) Proportional type and 3-position type -10 Speed ow speed: 60s/90 High speed: 30s/90 Function Introduction Proportional Type Control signal/feedback signal: 0~10VDC position Type (the terminal O,E,Y doesn't work) RS485 Bus Communication When TW...is proportional type, terminal B,O is power input, actuator can be controlled by connecting terminal O,E As shown in the left, when equipped with our TB.../TBF...series Ball Valve, DIP Switch is DA mode: Control signal at terminal O,E increasing: actuator runs to 1, valve tends to open Control signal at terminal O,E decreasing: actuator runs to "0", valve tends to close Control signal at terminal O,E has no changing, actuator shaft and valve stem stay in present position. When voltage (or current) signal is disconnected, this is equivalent to input a min. control signal, actuator runs to "0", valve closed. When TW...is 3-position type, terminal B,O is power input, control the actuator by the switch O,,: O, connected: When TW...is RS485 bus communication, terminal B,O is power input, remote control by terminal 8,9: Actuator can be controled remotely by RS485 bus communication, actuator supports ModBus protocol. Terminal O,E,Y,, doesn't work! actuator runs to "1", valve tends to open O, connected: actuator runs to 0, valve tends to close Terminal E,Y doesn't work by this time! Tiger Controls Equipment Co.,td 3
4 Wiring Instruction 1. Open the cover when wiring,prohibit to disassemble other spare parts! 2. Carefully check the power voltage when wiring, wire according to the product parameter, if not, it may cause fire and endanger personal safety in servere case! 3. Please cut off power supply during wiring in order to ensure personal safety! 4. After wiring,please install the cover to the origional position,avoid electric shock for the terminal! 1.Open the cover and prepare to wire. 2.Wire correctly according to the wiring diagram. a.24v Terminal Diagram Functional DIP Switch RS485 Functional Terminal Proportional Terminal 3-position Terminal SPDT Feedback Terminal b.220v Terminal Diagram Power Terminal Functional DIP Switch RS485 Functional Terminal 3-position Terminal Proportional Terminal SPDT Feedback Terminal COM O COM O TW...-BX24...wiring diagram Wiring Diagram COM O COM O Control Signal Feedback Signal RS485 Control Signal Feedback Signal D- D+ Proportional Type With RS485 and FC Function RS485 D- D+ COM O COM O 3-position Type With SPDT Feedback Function Tiger Controls Equipment Co.,td 4 COM O COM O Control Signal Feedback Signal
5 Control Signal Feedback Signal TW...-BX220...wiring diagram RS485 Control Signal Feedback Signal D- D+ Proportional Type With RS485 and FC Function COM O COM O 3-position Type With SPDT Feedback Function Indicating ight Reset ight Reset Status Description Green Always ormal mode Red Always ocal mode Yellow Flashing(1Hz) Self-stroking Red Quick flashing(2hz) Alarming Retractive ight-up UP Status Description Green Always ormal mode Yellow Always Reach upper limit position Red Flashing(1Hz) Alarming Red Always ocal mode Extended ight-dow DOW Status Description Green Always ormal mode Yellow Always Reach lower limit position Red Flashing(1Hz) Alarming Red Always ocal mode Tiger Controls Equipment Co.,td 5
6 Debugging Instruction A. Connect actuator and valve body. B. Wiring power and control signal wires. C. Set DIP Switch to needed position. After the setting, turn on power of actuator, pre-setting function will come into effect. (DIP Switch can be set with power) D. Power on the actuator. E. Actuator self-stroking: this step is for matching stroke of actuator and valve. 1)When self-stroking, the Reset yellow indicating light will keep flashing(1hz), actuator runs to 1 limit position firstly(valve open), then runs to 0 limit position(valve close), actuator will not controlled by control signal by this time. 2) After 2 minutes, Reset yellow light stop flashing, self-stroking stops and the matching of the valve and actuator is finished. By then, actuator running direction can be controlled by control signal. 3) If the Reset red light is quick flashing(2hz) during the self-stroking, it means the self-stroking status is not correct and the actuator start alarming. The actuator can not match with the valve's max. stroke. Remarks: If self-stroking is needed in a power-on state, press down the Reset button over 5 seconds, and then the actuator start self-stroking. Self-stroking phenomenon is the same as step 1), 2). F. ocal mode: press the button, at the same time over 5s, loosen the buttons and the actuator start the local mode. At this time, the, and Reset lights are in red. If the valve need to be open, long press the button and it will turn to green. If the valve need to be closed, long press the button and it will turn to green. After it reaches the expected position, repress, at the same over 5s and then it will exit the local mode. 1. The factory default setting is automatic self-stroking, it means that the actuator will repeat automatic self-stroking when power on each time! 2. If you don't need automatic self-stroking function, you can set the 7th switch to, it will change into manual selfstroking(phenomenon is the same as step 1), 2). Installation Orientation Medium is chilled/hot water Downward installation is forbidden Installation otes When install the valve with pipeline, please pay attention to the flow direction in valve should be consistent with the medium of pipeline! Tiger Controls Equipment Co.,td 6
7 Installation Instruction 1. In order to make the valve and actuator match better,please make sure the valve is full-closed and the actuator opening pointer is at the 0 position before installation. The arrow at the top of valve shaft is to up,vavle is closed. Please pay attention to the valve opening and actuator position when assembling the valve and actuator! Flow direction The arrow at the tope of valve shaft is to the right,valve is fully opened. Please set aside removable distance when installing on pipeline! 2.Align to the screw hold,install actuator vertically on the valve body. 3.Tighten the screw by allen wrench. 10mm Manual Device Operation Under the situation of power off, the actuator needs self-stroking again after the manual operation is completed. Manual self-stroking method: press the Reset for over 5s. 1 Shut off and take down the Allen wrench prepare 2 for manual operation. 3 Turn the Allen wrench anticlockwise, the valve open; 4 Turn the Allen wrench clockwise, the valve close. Insert the Allen wrench into the manual hole on the top of the cover. S=5mm (Allen wrench) Manual operation is done, take out the wrench and put it back cover tightly the red plug. Tiger Controls Equipment Co.,td 7
8 Dimension Figure D Rp H1 H 15 1/ / / / D D D2 K H1 H Technical Parameters Operating Parameters-valve body Caliber Range Pressure Flow Characteristic Rangeability >100 eakage Rate D15~D150 D15~D50:P25 D40~D150:P16/P25 are optional Equal Percentage One way zero leakage (A-AB zero leakage) *Permissible medium temperature -5~+120 Connection standard D15~D50: threaded connection ISO 7/1 D40~D150:Flanged connection ISO Spare parts materials-valve body Valve body Valve core Valve stem Sealing ring D15~D50 Brass D40~D150 Ductile iron Stainless steel Stainless steel FKM Tiger Controls Equipment Co., td 8
9 Technical Parameters Operating Parameters-actuator Rated torque Electric motor Operating Voltage TW...-BX24... TW...-BX Frequency Power consumption TW10M/TW15M/TW20M-BX24... TW50M-BX24... TW10M/TW15M/TW20M -BX TW50M-BX Running speed Sensitivity (can be adjusted between 0.5%~10% by FC mobile software) Dead zone( Can be adjusted between 1%~10% by FC mobile software) Impedance (only for proportional type) voltage input impedance current input impedance Parallel Operation TW...-BX24... oad requirements (only for proportional type) voltage output load requirement current output load requirement Control signal TW...-BX... TW...-BX Valve position feedback signal TW...-BX... TW...-BX...-F2 TW...-BX Protection evel ife cycles 10.M/ 15.M/ 20.M/ 50.M DC Brushless Motor 24VAC± 15%, 24VDC+ 15%, % 50Hz or 60Hz available Run:6VA; Max.:25VA Run:27VA; Max.:30VA Run:10VA; Max.:20VA Run:20VA; Max.:40VA High speed:30s/90 ; ow speed:60s/90 Proportional type: 1.0% (factory setting) RS485: 0.5% (factory setting) 3% (factory setting) >100K <0.125K <10 pcs(depending on controller output impedance) >1K <0.5K 0(2)~10VDC, 0(4)~20mA RS485 0(2)~10VDC, 0(4)~20mA 2 SPDT feedback RS485 IP thousands cycles Spare parts materials-actuator Cover Base PC Aluminum die casting Environment Conditions Operation Ambient temperature: Ambient humidity: Transport Ambient temperature: Ambient humidity: Storage Ambient temperature: Ambient humidity: -15~+55 95% RH -25~+70 95% RH -15~+55 95% RH Certificates CE conformity PED directive EMC directive ow-voltage directive Machinery Directive EMS QMS OHSAS 2014/68/EU 2014/30/EU 2014/35/EU 2006/42/EC ISO14001:2004 ISO9001:2008 OHSA18001:2007 Tiger Controls Equipment Co., td 9
10 RS485 Communicatiion function(optional) RS485 Communication: there is RS485 communication interface on the PCB RS485 Communication can set the control mode of actuator:remote(modbus)control, ocal control. It can control the actuator opening remotely. It can read the valve position feedback value remotely. It can read the actuator operating status remotely. It can remotely set the actuator operating speed, dead zone and so on. FC ear Field Communication(Optional) FC supports the actuator's parameter reading and setting without the electricity supply. Open the mobile FC client and close to the actuator FC scanning area. After connected, it can set the actuator parameters. As shown on the left, the FC client mainly contains the Actuator basic parameters, Actuator configuration parameters and Advanced functions, the functions of each part are shown as below: Actuator basic parameters: the actuator feedback,running cycle,current time and valve stroke can be read. Actuator configuration parameters: the actuator curve type,running speed,actuator address, opening range, dead zone,sensitivity can be set. Advanced functions: it contains signal division and conversion function, winter and summer mode conversion function and so on. 1.Current type actuator can't set signal division,please use the function after setting voltage type. 2.The factory default of winter and summer mode conversion function is close state, when using the function, actuator must in a power on state. 3.The default address is 1. Tiger Controls Equipment Co., td 10
11 Follow the TigerControls WeChat Official Account Information contained in this document, such as product design, specifications, or appearance, is subject to change without notice. This information is for reference only, please prevail in kind when buying.
Flow Limiter TPF...Series
Rev.E Flow imiter TPF...Series Flow limiter is a self-flow controller, mainly used in district heating system, it can not only regulate valve flow but also play hydraulic balance effects for the first
More informationPressure Independent Control Valve ---PICV TPL...Series
Rev.C Pressure Independent Control Valve ---PICV TP...Series Features Introduction High Control Precision Both the electric valve core and balancing valve core adopt straight travel design. Compared with
More information2-Port Ball Valve Threaded connection for PN25/ Flanged connection for PN16
Datasheet No. TBL-3.0 2-Port Ball Valve connection for PN25/ Flanged connection for PN16 Caliber:DN15...DN50: connection, DN65...DN150:Flanged connection Valve body material:dn15...dn50:stainless steel,
More informationPressure Independent Control Valve ---PICV(FCU)
Rev.A Pressure Independent Control Valve ---PICV(FCU) TD2L...Series It is used to solve the problem of hydraulic power maladjustment in heating and air conditioning system.it has a strong anti-jamming
More information---Pressure Independent Control Valve
Datasheet No.: TPF-02 PICV for AHU TPF-Series ---Pressure Independent Control Valve Valve body material:ductile iron QT450-0 Caliber:DN50...DN250 Flow rate range:3...240m3/h Standard of flange connection
More informationValve Body Material:Ductile iron QT Caliber:DN50...DN250 Standard of flange connection in accordance with ISO7005-2
Datasheet No.: TPF-B-0 TPF-Series Flow Limiter Valve Body Material:Ductile iron QT450-0 Caliber:DN50...DN250 Standard of flange connection in accordance with ISO7005-2 Characteristics Valve Stroke: Max
More informationStatic Balancing Valve
Rev.A TJL...Series DN15~DN50 TJF...Series DN50~DN500 Static Balancing Valve Features Introduction Digital Handwheel Accurate scale on digital handwheel which could accurate to 0.1 cycle. The humanized
More informationVPA Series and VAP Actuator
VPA Series and VAP Actuator PN6 Flanged Pressure Independent Balancing and Control Valve Product Bulletin PB_VPA_06 204 VPA Pressure Independent Control Valve is a combination of a differential pressure
More informationVA-7000 SERIES ACTUATOR
VA-7000 SERIES ACTUATOR DESCRIPTION VA-7000 series actuator is electromechanical product, and can be mounted on VB-7000 series valves. If with different connectors, it can be fitted with other kinds of
More informationOverview of types. Technical data
Technical data sheet 6..S+NVFT24-MFT-E Globe valves, 2-way, with flange PN 16, actuator with emergency control function for closed hot water systems up to 150 C in district heating applications approved
More informationGlobe Valve Model Description Globe Valve, Hot Water or Steam Applications
Description VG series accurately regulate the flow of water or steam in response to the demand of a controller in heating,ventilating and air conditioning systems. These valves are available in normally
More informationNV Direct Coupled Globe Valve Actuator
70396 Rev. C Non-spring return, on/off, floating point, proportional control NV Direct Coupled Globe Valve Actuator NV24-3 US NVD24-3 US NV24-MFT US NVD24-MFT US Application For on/off, floating point
More information20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves
VFB30 Series Issue Date February 1, 2016 20 to 150 mm 2-Way Automatic Flow Balancing Control Ball Valves Low Torque Facilitates the use of smaller, less expensive directmount rotary-motion actuators Extends
More informationF6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc Application Valve is designed f use in ASI flanged piping systems to meet the needs of bi-directional high flow HVAC hydronic
More informationGlobe Valves. Technical Databook Version 1.2. Belimo Asia Pacific
Globe Valves Technical Databook Version 1.2 Belimo Asia Pacific Contents Globe Valves Product Overview Max. Close-off Pressure - Globe Valve Series Globe Valve Actuators Product Overview 4 5 General Information
More informationSAX Electronic Valve Actuator
SAX Electronic Valve Actuator Non-spring Return, 24 Vac, Proportional Control Technical Instructions Document No. 155-506 Description The SAX Non-spring Return (NSR), Electronic Valve Actuator requires
More informationVG9000 Flanged Valves
VG9000 Flanged Valves DN15..., PN6 and PN10 Product Bulletin This improved VG9000 Series cast iron flanged valves are designed primarily to regulate the flow of water and low pressure steam in response
More informationSAX Electronic Valve Actuator
Document No. 129-561 SAX Electronic Valve Actuator Product Description The SAX Electronic Valve Actuator requires a 24 Vdc or 24 Vac, Class 2, supply signal to control a Flowrite 599 Series valve or a
More informationChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves
- Motorized 6-port Ball Valves Description NovoCon The and NovoCon are 6-port motorized ball valves that performs a diverting function between two water circuits in 4-pipe changeover system. This diverting
More informationMVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam
Document No. 125-4361 VF461H Series odulating Control Valves with agnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam Description Control valves with magnetic actuators,
More information2-Way & 3-Way Non Spring Return Characterized Ball Valves
VCB30 Series Revision Date June 6, 2014 2-Way & 3-Way Non Spring Return Characterized Ball Valves General The VCB30 Series electric rotary-motion actuatordriven characterized ball valves are designed specifically
More informationF6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc Application Valve is designed f use in ASI flanged piping systems to meet the needs of bi-directional high flow HVAC hydronic
More informationF6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F6250, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc Application Valve is designed f use in ASI flanged piping systems to meet the needs of bi-directional high flow HVAC hydronic applications
More informationP2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends
P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends Application Water-side control of heating and cooling systems for AHUs and water coils. Equal Percentage/
More informationF6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F6250, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc Application Valve is designed f use in ASI flanged piping systems to meet the needs of bi-directional high flow HVAC hydronic applications
More informationF6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F6200, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc Application Valve is designed f use in ASI flanged piping systems to meet the needs of bi-directional high flow HVAC hydronic applications
More informationPN [ ] D7150NL/BAC D7200WL/BAC D7250WL/BAC D7300WL/BAC [ ]
Technical data sheet D7../C utterfly valve with actuator, Flange, P 16 Torque motor 160 m ominal voltage C 24...240 V / DC 24...125 V Control Open-close, modulating, communicative for mixing and diverting
More informationModulating control valves with magnetic actuators, PN 16
4 461 Modulating control valves with magnetic actuators, PN 16 for drinking water, cold water and hot water systems, DVGW approved MXG461B.. Short positioning time (< 2 s), high resolution (1 : 1000) Selectable
More informationSS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments
Smart Valve Positioner SS3 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)
More informationControl valves with electric actuators up to 90 C PN
Features Suitable for the control of hot and chilled water (0...+90 C) in drinking water systems Valves with DVGW test mark reg. no. DW-6340BP0198 acc. latest German Drinking Water Ordinance (TrinkwV 2001)
More informationF6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc
F6300, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc Application Valve is designed f use in ASI flanged piping systems to meet the needs of bi-directional high flow HVAC hydronic applications
More informationElectromotoric Actuators
4 863 Electromotoric Actuators for zone valves VVI46, VXI46, VVS46 and VXS46 SFA21/18 SFA71/18 SFA21/18 AC 230 V operating voltage, 2-position control signal SFA71/18 AC 24 V operating voltage, 2-position
More informationElectromotoric actuators
s 4 520 ACVATIX TM Electromotoric actuators SQL321B.. SQL361B.. For VKF42.. butterfly valves SQL321B.. Operating voltage AC 220 V, 2-position (SPDT) control signal SQL361B.. Operating voltage AC 220 V,
More informationElectronic Globe Valves
Electronic Globe Valves NV Non-Spring Return On/Off, floating: NV24-3 US Proportional (2-0 VDC Default): NV24-MFT US NVF Spring Return Proportional (2-0 VDC Default) On/Off, floating: NVF24-MFT US Spring
More informationDA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators
Datasheet 53lb-in (6 Nm), Non-Spring Return Damper Actuators Overview The direct-coupled fail-safe/failin-place electronic actuators are designed for modulating, two position, and floating control of laboratory
More informationModel TUR-200D Turbine Flowmeter
General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.
More informationCombi valves PN 16 with flanged connections
4 315 ACVATIX Combi valves PN 16 with flanged connections Pressure Independent Combi Valves VPF43.. With integrated pressure differential controller Valve body made of gray cast iron GJL-250 DN 50, DN
More informationSeries 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability
Series 60 New Smart Positioner Compact design Convenient & powerful function Enhanced reliability J Flow Controls, LLC 14 De Camp Cincinnati, OH 45216 Phone: 513-731-2900 Fax 513-731-6939 www.jflowcontrols.com
More informationProduct bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings
Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings ST2 Ball valves in conjunction with spring return and non-spring return VA-Actuators Developed for HVAC applications
More informationModulating control valve PN16 with magnetic actuator
Modulating control valve PN with magnetic actuator for hot and chilled water with positioning control and position feedback MP...GY MP...FY MP...GY MP...FY Mixing or straight-through valves with magnetic
More informationFlowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control
Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control Document No. 55-8P25 EA 599-4 EA379R Description The Flowrite EA 599 Series SKD Electronic Valve Actuator requires a 24
More informationHarmony Installation, Operation and Maintenance
Harmony Installation, Operation and Maintenance IMI FLOW DESIGN / Installation - Maintenance / F402.0 Harmony IOM Harmony Technical Description Application: HVAC, Chilled and Hot Water Hydronic Systems
More informationNFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V
NFB4, NFB4-S, NFX4, NFX4-S On/Off, Spring Return, 4 V Torque min. 90 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection NFB4... NFX4...
More informationKNC-SRV-FD123-EA-000 Series Servo Driver
FEATURES DESCRIPTION Input Voltage Range From DC24VDC to 70VDC Rated Current is (RMS) 10A 50-200 Watt Power Range Position, Speed, and Torque Control RS232 and Natural Air Cooling MODBUS and CANopen Standard
More informationTRF.. series spring return rotary actuators for CCV
TF.. series spring return rotary actuators for CCV Spring return rotary actuators: For ball valves DN 5.. Torque: 2 Nm Modulating control TF24-S (C/DC 24 V) Floating (3-point) control TF24-2 (C/DC 24 V)
More informationModulating control valve PN16 with magnetic actuator
Modulating control valve PN with magnetic actuator for hot and chilled water with positioning control and position feedback MP80FY MP00FY Mixing or straight-through valves DN80 and DN00 with magnetic actuator
More informationModulating control valves with magnetic actuators, PN 16
4 461 Modulating control valves with magnetic actuators, PN 16 for drinking water, cold water and hot water systems, DVW approved MX461B.. Short positioning time (< 2 s), high resolution (1 : 1000) Selectable
More informationKNC-SRV-FD123-CA-000 Series Servo Driver
FEATURES DESCRIPTION Input Voltage Range From DC24VDC to 70VDC Rated Current is (RMS) 10A 50-200 Watt Power Range Position, Speed, and Torque Control RS232 and CAN BUS Natural Air Cooling MODBUS and CANopen
More informationBACnet MS/TP Networking Flow Balancing Control Valves
VFB30 Series Revision Date May 8, 2013 BACnet MS/TP Networking Flow Balancing Control Valves Establishes a flow coefficient (Cv) similar to globe valves, eliminating the need for pipe size correction tables
More informationSS2 Linear / Rotary Smart Valve Positioner
COTROLS A Division of AT Controls Smart performance with innovative and ever-strong coil drive even under harsh working environments Also available in REMOTE TYPE 316 STAILESS STEEL BODY Smart performance
More informationPower Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.
Switching Expandable and space-saving switching power supplies. High efficiency reduces operation costs. 93% efficiency Plug-in output modules for additional output voltages Plug-in branch terminal module
More informationSuperstatic 440. Static Heat- and Cooling Meter. Application
Superstatic 440 Static Heat- and Cooling Meter Application Design The Superstatic 440 is a static heat- and cooling meter according to standard EN1434 class 2 based on the fluid oscillation principle,
More informationType Electrically Actuated Ball Valve
Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement socket, threaded,
More informationTechnical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application
Document No. 155-180P25 Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description The Flowrite 599 Series SKD6xU Electronic Valve Actuators require a 24 Vac supply and
More informationPS6R 480W Switching Power Supply
ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor
More informationEMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com
EMUJC Series Electronic actuator Technical Data Sheet WattsIndustries.com Description Watts Water Technologies, Inc. The actuator EMUJC Series is an electronic device with 3-point or proportional control
More informationVA-4233-GGx Series Electric Valve Actuators
Installation Instructions Issue Date August 11, 2003 VA-4233-GGx Series Electric Valve Actuators Installation Refer to Figures 2 through 4 for proper actuator orientation before attempting to make the
More informationVA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design
VA-7150 Electric Valve Actuator European Electronic Controls Catalogue Section E Product Bulletin VA-7150 Issue Date 03 2000 I ntroduction The VA-7150 series synchronous motor driven actuator provides
More informationModulating control valves with magnetic actuator PN 16
4 465 ACVATIX Modulating control valves with magnetic actuator PN 16 stainless steel MXG461S.. Fast positioning time (
More informationG7 (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim
G (S) 3-way Mixing Flanged Globe Valve, Bronze or Stainless Steel Trim pplication This valve is typically used in Large ir Handling Units on heating or cooling coils. This valve is suitable for use in
More informationMount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)
EFB and EFX Series Spring Return Direct Coupled Actuator Minimum 70 in-lb Torque For damper areas up to 66 sq-ft* (For lower torque, see AFB, AF, NFB, LF, or TF series) Applications New standard clamp
More informationModulating control valve PN16
8 Modulating control valve PN with magnetic actuator for HTHW and steam, with positioning control and position feedback MH...FY...N Control valve with magnetic actuator for modulating control in district
More information2- and 3-port valves with flanged connections, PN 16
4 404 VXF43.. ACVATIX 2- and 3-port valves with flanged connections, PN 16 From the large-stroke valve line VXF43.. High-performance valves for medium temperatures from -20 220 C Valve body of nodular
More informationTechnical Instructions. SQV Series Electromotive Valve Actuators. Document No
Document No. 155-521 (For Use with 2-1/2-Inch to 6-Inch Pressure Independent Control Valves) Features Operating voltage: AC/DC 24V Application Control signals: 3-position, DC 0 to 10V, DC 4 to 20 ma Fail-safe
More informationFig Single-Acting Rotary Smart Positioner
Fig. 3303 Single-Acting Rotary Smart Positioner Order Information Model No. EC03303RSN52000S Econ series 3300 Smart Positioner for quarter turn actuators in single acting version. This positioner regulates
More informationModulating Control Valve PN 16 with Magnetic Actuator
4 74 Modulating Control Valve PN 6 with Magnetic Actuator for brine circuits, hot water, steam or media containing mineral oils (MK FX NP) MK FX N MK FX NP Fast positioning time (< s) High-resolution stroke
More informationPKS-FD Servo System
PKS-FD123-01 Servo System FEATURES 24-70VDC of 0.32 Nm Power Ratings up to 100 Watts 2,500 PPR Incremental Encoder Maximum Speed of 6500 RPM IP65 for Body, IP54 Shaft Seal Brake Option Available Position,
More informationELECTRIC ACTUATORS 400 N
ELECTRIC CTUTORS 400 N SE4 PPLICTION Electric actuator SE4 is suitable to drive valve body series in HVC systems. Two action types are available: - floating (3-point) - modulating Vdc and m. ctuator is
More informationProfibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output
: Standard Profibus-DP signal Rugged fully closed design Linear, absolute measurement LEDs for sensor diagnostics Digital technology, stable and reliable Non-contact sensing technology Superior accuracy,
More informationFlowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features
Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features Technical Instructions Document No. 155-717 EA-599-18 SKB/C SKD Description The Flowrite
More informationFlowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features
Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features Technical Instructions Document No. 55-77 EA-599-8 April 3, 24 EA228R EA379R SKB/C SKD
More informationHERZ Motorised Actuator
HERZ Motorised Actuator Data sheet for HVACT Issue 1017 Dimensions Models HVACT24-01 HVACT230-01 HERZ Motor Valve Drive, Floating 3-point, M28 x 1.5, 24 V, 50 Hz actuating force 140 N, operating voltage
More informationLinear Valve Electric Actuator
Linear Valve Electric Actuator www.powervalves.nl Company Profile Company Profile Sun Yeh Electrical Ind. Co., Ltd. was founded in 1986. We always strive for technical excellence, innovation and the highest
More informationKNC-PKS-FD S-AAK-DKH
KNC-PKS-FD123-02 - Servo System FEATURES 24-70VDC of 90 oz-in Power Ratings up to 200 Watts 2,500 PPR Incremental Encoder Maximum Speed of 6000 RPM IP65 for Body, IP54 Shaft Seal Brake Option Available
More informationFlowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features
Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features Technical Instructions Document No. 155-717 EA-599-18 SKB/C SKD Description The Flowrite
More informationActuators for small valves
Actuators for small valves with 5.5 mm nominal stroke 4 891 SSB31... SSB81... 80130 80117 SSB... without auxiliary switch SSB...1 with auxiliary switch Electro-mechanical actuators for valve types VMP45...,
More informationBarrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)
Barrier Gate Manual (DZX2. Control Board) (The third version) (Pictures for reference only, the product prevail in kind) Contents. Brief Introduction... 2. Functions and Features... 3. Technical Data...2
More informationAEL6 Series Smart Electric Actuators for ½" to 4" Control Valves
Materials No. Part Material Case 57 lbf to 798 lbf Polycarbonate 347 lbf to 560 lbf Die-cast aluminium Housing Die-cast aluminium 3 Guidance Red brass Description The AEL6 series electric actuators are
More informationZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators
ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators The ZG-JSL jackshaft linkage is designed to easily attach to any part of a jackshaft and allow easy installation
More informationInstallation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System
Description of Device VALMAC Posi-Zest SP-2100 Series is the advanced control device for a rotary control valve that provides unparalleled stability in difficult environments. Easy Maintenance Precise
More information2-Port and 3-Port Zone Valves, PN16
4 867 2-port valves MVI421.15 to MVI421.25 2-Port and 3-Port Zone Valves, P16 3-port valves MXI421.15 to MXI421.25 MVI421... MXI421... Operating voltage C 230 V, 2-position control signal Spring return
More informationElectro-hydraulic actuators for valves
4 564 Electro-hydraulic actuators for valves with a 40 mm stroke SKC32... SKC82... SKC62 SKC60 SKC32... Operating voltage AC 230 V, 3-position control signal SKC82... Operating voltage AC 24 V, 3-position
More informationElectric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes
Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes SERIES Features Direct mount Full Port 16 Stainless Steel ball valve 2-piece ANSI Class 150 flanged body
More information2- and 3-port valves with flanged connections, PN 16
4 404 VVF43.. VVF43..K VXF43.. ACVATIX 2- and 3-port valves with flanged connections, PN 16 From the large-stroke valve line VVF43.. VXF43.. High-performance valves for medium temperatures from -20 220
More informationFlare Valves 1/2 inch 2-Way and 3-Way
Valve and Actuator Manual 977 Valve Product Information Section Product Bulletin VTF Series Issue Date 0596 Flare Valves 1/2 inch 2-Way and 3-Way The 1/2 inch flared valve line is designed to accurately
More informationVE VVG Series Electronic Two-way Valves Normally Closed
VE VVG Series Electronic Two-way s Normally Closed Document No. 155-112P25 VE VVG-1 Description The VE VVG electronic two-way valves control the flow of water or glycol solutions. The electronic actuator
More informationVersatile and Powerful
AM Series Direct Coupled Actuator Versatile and Powerful Minimum 180 in-lb torque in a compact package. For damper areas up to 45 sq-ft* All Actuators have BDCM AM Series - At A Glance AMB(X)24-3 (p. 148)
More information2-Port and 3-Port Zone Valves, PN 16 / 20
4 867 2-port valve MVI421.15 to MVI421.25 3-port valve MXI421.15 to MXI421.25 2-Port and 3-Port Zone Valves, P 16 / 20 Max. permissible pressure 2000 kpa MVI421.. MXI421.. Operating voltage C 230 V, 2-position
More informationElectric Flanged PN16 Cast Iron Ball Valve
Electric actuator direct mounted Type: E4813BS Electric actuator fitted via kit Main J3 Smart electric actuator features: LED light for continual visual actuator status feedback. Fully weatherproof smart
More informationActuators for modulating control AME 110 NL, AME 120 NL
Actuators for modulating control AME 110 NL, AME 120 NL Description The actuators are used together with automatically balanced combination valve type AB-QM for DN 10-32. The actuator can be used with
More informationMXG MXF Modulating control valves PN 16 with magnetic actuators. Building Technologies HVAC Products
4 455 MX461... MXF461... Modulating control valves PN 16 with magnetic actuators for chilled and low-temperature hot water systems MX461... MXF461 Fast positioning time (< 2 s), high-resolution stroke
More informationMS Application. Features. Proportional Valve Actuator General Instructions
Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and
More informationFlowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control
Document No. 155-507 Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control Description The Flowrite 599 Series SAX Non-spring Return (NSR), Electronic Valve Actuator
More informationPRODUCTS CATALOG (2018) TISSIN CO.,LTD. Smart Valve Positioner. Electro-Pneumatic Positioner. Volume Booster. Lock Up Valve. Air Filter Regulator
PRODUCTS CATAOG (08) TISSIN CO.,TD. Smart Valve Positioner Electro-Pneumatic Positioner Volume Booster ock Up Valve Air Filter Regulator Solutions for control valve system About Tissin Solutions for control
More informationOperating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3
Operating Instructions Pneumatic Control Valve Low Temperature Type 8026 Series GS3 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 03/2006
More informationAKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve
Product data sheet 5.1 51.364 AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve How energy efficiency is improved Automatic adaptation to ball valve, precise activation
More informationLiquid Turbine Flow Meter OwnerÊs Manual
Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...
More informationCharacterised Control Valves with Actuators
Characterised Control Valves with Actuators Technical Databook Version 8.6 Belimo Asia Pacific Contents Control Valves and Actuators Product Overview 4 Characterised Control Valve 6 Sizing of Ball Valves
More informationFlowCon Energy FIT System
Energy FIT System Energy-Saving Pressure and Temperature Independent System 65-250 mm / 2 1/2-10 SPECIFICATIONS PICV valve: Static pressure: 4000 kpa / 580 psi Ambient temperature: -10 C to +50 C / +14
More informationMODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )
Final Control Elements SERVO-TOP II ELECTRONIC ACTUATOR (linear type; max. thrust 5000 N) Functions & Features Control valve actuator drive I to I positioner incorporated Lightweight, compact design High
More information