Packaged L Series LCA/LGA/LHA

Size: px
Start display at page:

Download "Packaged L Series LCA/LGA/LHA"

Transcription

1 Packaged L Series LCA/LGA/LHA Model /2 Tons Cooling Cap. 83,000-80,000 Btuh Heating Cap. 86,000 Heat Pump Heating Cap. 9,00 to 53,600 Btuh Optional Electric Heating GUK FEATURES Down flow or horizontal supply and return air configuration E.T.L. and C.G.A. listed, efficiency rating verified by C.S.A., components bonded for grounding to meet safety standards for servicing required by U.L., C.S.A. and National and Canadian Electrical Codes ARI Standard 20/ certified Bottom power entry for electric and gas Heavy gauge galvanized steel cabinet, fully insulated, powdered enamel paint finish, hinged access panels, electrical inlets in cabinet base and electric heat end panel, easy access control area with factory installed controls, low voltage terminal strip, unit lifting holes in full perimeter base rail Coil constructed of ripple-edged enhanced aluminum fins on copper tubing, flared shoulder tubing connections, silver soldered construction, factory tested, evaporator coil face split with separate circuits, indoor coil drain connection extends outside of unit cabinet Compressor crankcase heater Reciprocating type compressors, resilently mounted on rubber grommets (LGA/LCA models) Copeland Compliant Scroll compressor for high efficiency, resiliently mounted on rubber grommets (LHA model) Integrated Modular Control (IMC) - solid sate board contains all controls and control relays to operate unit with unit diagnostics Tubular constructed, aluminized steel heat exchanger life cycle tested (LGA models) Heating system includes aluminized steel inshot burners, direct spark ignition, electronic flame seonsor, redundant automatic dual gas valve with manual shut-off, induced draft blower, flame rollout switch (LGA models) Outdoor coil fan - PVC coated fan guard furnished Outdoor coil fan motor overload protected, permanently lubricated, equipped with ball bearings, shaft up, wire basket mount Disposable 2" pleated filters furnished Refrigeration system consists of compressors, outdoor coil and direct drive fan, indoor coil and belt drive blower, check and expansion valves (indoor and outdoor), high capacity drier, high pressure switch, low pressure switch, reversing valve (LHA model), defrost control (LHA model), full refrigerant charge, crankcase heater, freezestat (prevent coil freezeup during low ambient operation or loss of air), and accumulator Supply air blower - belt drive, forward curved blades, blower wheel statically and dynamically balanced, ball bearings, adjustable pulley (allows speed change), blower assembly slides out of unit for servicing Supply air motor overload pretected, equipped with ball bearings 70VA transformer with built-in circuit breaker Year warranty on parts 5 Year warranty on compressor 0 Year warranty on heat exchanger

2 222 LCA/LGA/LHA088 Model Number Guide L H - A S - Y Unit Type L = Commercial Package Unit H = Heat Pump G = Cooling w/gas Heat C = Cooing Only (w/opt Electric Heat) Voltage Y = 208/230v-3 phase-60hz G = 460v-3 phase-60hz J = 575v-3 phase-60hz Minor Revision Number Major Design Sequence Heat Type (S or H) Cooling Tons (kw) Cooling Efficiency 088 = 7.5 (26.4) S = Standard Efficiency Required Options - Items Must be Ordered and Factory Installed Air low Configuration - specify horizontal or down-flow when ordering base unit Supply Air - (See Blower Data Table for specifications) Drive Kit - Order one (see Drive Kit Specifications Table) Voltage - specify when ordering base unit Gas (LGA Models Only) - Order one: 83,000/25,000 Btuh (24.3/36.6 kw) (low/high fire) Standard Heat Gas 9,000/80,000 Btuh (34.8/52.7 kw) (low/high fire) High Heat Gas Optional Accessories - Items Must be Ordered and Factory Installed Item LCA/LGA/LHA088 ¹Disconnect Switch - Accessible from outside of unit, spring loaded weatherproof cover furnished actory Service Outlets (2) - 5v ground fault circuit interrupter (G CI) type actory ¹ Not available for LCA model with field installed electric heat, LHA 208/230v models with 5 kw, 30 kw or 45 kw electric heat or for LHA 460v models with 45 kw electric heat.

3 3 Optional Accessories - Field Installed Item LCA/LGA088 LHA088 Blower Proving Switch - Monitors blower operation, shuts down unit if blower fails 8L89 Dirty ilter Switch - Senses static pressure increase indicating a dirty filter condition 30K48 Down- low Gravity Exhaust Dampers - Aluminum blade dampers prevent blow back and LAGED08/0-8 lbs. (4 kg) outdoor air infiltration during off cycle, bird screen furnished - Net Weight. NOTE - See below (7L79) for damper hood. Down- low Gravity Exhaust Dampers Hood - Net Weight 24L5-25 lbs. ( kg) Economizer - Opposing gear driven recirculated air and outdoor air dampers, plug-in connections to units, nylon bearings, neoprene seals, 24 volt fully modulating spring return motor, adjustable minimum damper position, damper assembly slides in unit. NOTE - outdoor air hood must be ordered separately (see below), optional down-flow gravity exhaust dampers available (see above), choice of economizer controls (see below) - Net Weight Economizer Control Choice - Sensible Control - urnished on IMC board in unit, uses outdoor air sensor furnished with unit to measure outdoor air temperature and control damper position ( urnished) Global Control - urnished on IMC board in unit, used with Direct Digital Control (DDC) systems, uses global air sensor to control damper position, determines when to use outdoor air for cooling or set damper at minimum position ( urnished) Outdoor Enthalpy Control - Adjustable enthalpy sensor, senses outdoor air enthalpy for economizer control, 0 to 00% outdoor air Differential Enthalpy Control - Two solid-state enthalpy sensors allow selection between outdoor air and return air (whichever has lowest enthalpy) Horizontal Conversion Kit - Two piece duct cover in kit blocks off unit down-flow supply air opening, horizontal return air opening panel (on unit) is moved to block off down-flow return air opening for horizontal applications ¹Horizontal Gravity Exahust Dampers - Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, field installed in return air duct, bird screen and hood furnished - Net Weight Outdoor Air Damper Section - Linked mechanical dampers, 0 to 25% (fixed) outdoor air adjustable, installs in unit for down-flow applications NOTE: Outdoor air hood must be ordered separately (see below) - Net Weight Automatic - fully modulating spring return damper motor with plug in connection Manual Outdoor Air Hood - Required with LAREMD08/0 Economizer, LAOAD0/5 and LAOADM08/0 Outdoor Air Damper Sections, two cleanable aluminum mesh air filters furnished - Net Weight Power Exhaust an - Installs in unit for downflow applications only with economizer option, Model Number - Net Weight provides exhaust air pressure relief, interlocked to run when return air dampers are closed and supply air blower is operating, fan runs when Total air volume - cfm (L/s) outdoor air dampers are 50% open (adjustable), motor is overload protected, requires optional down-flow gravity exhaust dampers (see above) Electric Heat - ield installed, helix wound nichrome elements, time delay for element staging, individual element limit controls, wiring harness, may be two-stage controlled, requires use Block and Terminal Block Electric Heat use Block - Required with Electric Heat. Mounting screws furnished (LCA/LHA Models) Electric Heat LTB2 Terminal Block - Required with electric heat Smoke Detector - Photoelectric type, installed in supply air section or return air section or both sections ¹ ield installs in return air duct. Two dampers furnished per order no. LAREMD08/0-43 lbs. (20 kg) (7L54) (6K96) Outdoor (6K97) Differential 7L25 LAGEDH03/5-30 lbs. (4 kg) (53K04) LAOADM08/0-28 lbs. (3 kg) (7L55) LAOAD0/5-26 lbs. (2 kg) (66K69) LAOAH08/0 - lbs. (5 kg) ilter size: 6 x 20 x in. (406 x 508 x 25 mm) (7L52) LAPE 08/0-28 lbs. (3 kg) 208/230v (7L48)- 460v (7L49) - 575v (7L50) Diameter - in. (mm) Number of Blades20 (508) in. wg. (0 Pa) Horsepower (W) /3 (249) Total Watts 300 See Electric Heat Data Tables See Optional Electric Heat Accessories Table 6M24 - Supply 6M23 - Return

4 444 LCA/LGA/LHA088 Optional Accessories Item LCA/LGA088 LHA088 Aspiration Box - for duct mounting of Indoor Air Quality Sensor 90N43 Indoor Air Quality (CO2) Sensor - Monitors CO2 levels, reports to Integrated Modular Control (IMC) board which adjusts economizer dampers as needed 87N53 Coil Guards - Galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards 24L55 Diffusers - Aluminum grilles, large center grille, Step-Down - double RTD lbs. (40 kg) insulated diffuser box with flanges, hanging rings deflection louvers (29G04) furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to D lbs. (34 kg) lush - fixed blade louvers T-bar ceiling grids or plaster ceilings - Net Weight (29G08) Transitions (Supply and Return) - Used with diffusers, installs in roof mounting frame, galvanized steel construction, flanges furnished for duct connection, fully LASRT08/0-30 lbs. (4 kg) (24L4) insulated - Net Weight Downflow Roof Mounting rame - Nailer strip furnished, mates to unit, U.S. National Roofing 4 inch (356 mm) height LARM 08/ lbs. (54 kg) (7L53) Contractors Approved, shipped knocked down - Net Weight 24 inch (60 mm) height LARM 08/ lbs. (74 kg) (9L05) Hail Guards - Constructed of heavy gauge steel, painted to match cabinet, helps protect ourdoor coils from hail damage. Not used with Coil Guards 24L54 LPG/Propane Kits (LGA Model Only)4L

5 5 Specifications - LCA/LGA Model Model No. LCA/LGA088 Gross Cooling - Btuh (kw) 94,000 (27.5) Net Cooling - Btuh (kw) 88,000 (25.8) Cooling Ratings Total Unit Power (kw) 9.77 EER (Btuh/Watt) 9 4 Integrated Part Load Value (Btuh/Watt) Sound Rating Number (db) 86 Refrigerant Charge urnished Circuit 8 lbs. 0 oz. (3.63 kg) (HC C-22) Circuit 2 8 lbs. 0 oz. (3.63 kg) Heat Type Standard (S) High (h) (low) - Btuh (kw) 83,000 (24.3) 9,000 (34.9) Two Stage Heating Output (low) - Btuh (kw) 66,000 (9.3) 95,000 (27.8) (Natural or LPG/Propane Gas (high) - Btuh (kw) 25,000 (36.6) 80,000 (52.8) at Sea Level) Output (high) - Btuh (kw) 00,000 (29.3) 44,000 (42.2) A.G.A./C.G.A. Thermal Efficiency 80.00% Gas Supply Connections npt - in. - Natural or LPG/Propane 3/4 Recommended Gas Supply Pressure - wc in. (kpa) Natural 7 (.7) LPG/Propane (2.7) Blower wheel nominal dia. x width - in. (mm) () 2 x 2 (305 x 305) Nominal motor output - hp (kw) 2 (.5) Evaporator Blower and Drive Selection Evaporator Coil 2 hp (.5 kw) 3 & Drives Max. usable motor output - hp (kw) Voltage & phase 2.30 (.7) 208/230v, 460v or 575v-3ph (Drive kit #) RPM range () (3) Nominal motor horsepower (kw) 3 (2.2) 3 hp (2.2 kw) Max. usable motor output - hp (kw) 3.45 (2.6) 3 & Drives Voltage & phase 208/230v, 460v or 575v-3ph (Drive kit #) RPM range () (3) Net face area - sq. ft. (m2) 9.72 (.90) Tube diameter - in. (mm) & No. of rows3/8 (9.5) - 3 ins per inch (m) 4 (55) Drain connection no. & size - in. (mm) fpt () - (25.4) Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head Net face area - sq. ft. (m2) (2.2) Condenser Coil Tube diameter - in. (mm) & No. of rows3/8 (9.5) - 2 ins per inch (m) 20 (787) Diameter - in. (mm) & No. of blades() - 24 (60) - 3 Total Air volume cfm (L/s) 5300 (250) Condenser ans horsepower (W) /2 (373) rpm 075 Total watts550 ilter (furnished) Type of filter Disposable Commercial Grade Pleated No. and size - in. (mm) (4) 8 x 20 x 2 (457 x 508 x 5) Electrical characteristics 208/230v, 460v or 575v - 60 hz - 3 ph Rated in accordance with ARI Standard 20/240 and certified to ARI; 95 o (35 o C) outdoor air temperature and 80 o (27 o C) db/67 o (9 o C) wb entering evaporator air; minimum external duct static pressure. NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction 2 Sound Rating Number rated in accordance with test conditions included in ARI Standard Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. 4 Integrated Part Load Value rated at 80 o (27 o C) outdoor air temperature.

6 666 LCA/LGA/LHA088 Specifications - LHA Model Model No. LHA088S Gross Cooling - Btuh (kw) 9,000 (26.7) Cooling Ratings Net Cooling Capcity - Btuh (kw) 86,000 (25.2) Total Unit Power (kw) 9.6 EER (Btuh/Watt) 9 Total Heating - Btuh (kw) 86,000 (25.2) High Temperature Heating Total Unit Power (kw) 8.4 Ratings C.O.P. 3 Total Heating - Btuh (kw) 48,000 (4.) Low Temperature Heating Total Unit Power (kw) 7.03 Ratings C.O.P. 2 2 Sound Rating Number (db) 86 Refrigerant Charge urnished (HC C-22) 7 lbs. 0 oz. (7.7 kg) Blower wheel nominal dia. x width - in. (mm) 2 x 2 (305 x 305) Nominal motor output - hp (kw) 2 (.5) Indoor Blower and Drive Selection Indoor Coil Outdoor Coil Outdoor ans Max. usable motor output - hp (kw) 2.30 (.7) 2 hp (.5 kw) 3 Voltage & phase 208/230v, 460v or 575v-3ph s & Drives () (Drive Kit #) RPM range (3) Nominal motor output - hp (kw) 3 (2.2) Max. usable motor output - hp (kw) 3.45 (2.6) 3 hp (2.2 kw) 3 Voltage & phase 208/230v, 460v or 575v-3ph & Drives () (Drive Kit #) RPM range (3) Net face area - sq. ft. (m 2 ) 9.72 (.90) Tube diameter - in. (mm) & No. of rows3/8 (9.5) - 3 ins per inch (m) 4 (55) Drain connections no. & size - in. (mm) fpt () (25.4) Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head Net face area - sq. ft. (m 2 ) (2.2) Tube diameter - in. (mm) & No. of rows3/8 (9.5) - 2 ins per inch (m) 20 (787) Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head Diameter - in. (mm) & No. of blades24 (60) - 3 Total Air Volume - cfm (L/s) 5300 (250) horsepower (W) /2 (373) rpm 075 Total Watts550 Type of filter Disposable Commercial Grade Pleated ilters (furnished) No. and size - in. (mm) (4) 8 x 20 x 2 (457x 508 x 5) Electrical characteristics 208/230v, 460v or 575v - 60 hz - 3 ph Rated in accordance with ARI Standard 20/240 and certified to ARI Cooling Ratings - 95º (35ºC) outdoor air temperature and 80º (27ºC) db/67º (9ºC) wb entering indoor coil air High Temperature Heating Ratings - 47º (8ºC) db/43º (6ºC) wb outdoor air temperature and 70º (2ºC) entering indoor coil air Low Temperature Heating Ratings - 7º (-8ºC) db/5º (-9ºC) wb outdoor air temperature and 70º (2ºC) entering indoor coil air NOTE - ARI capacity is net and includes indoor blower motor heat deduction. Gross capacity does not include indoor blower motor heat deduction. 2 Sound Rating Number rated in accordance with test conditions included in ARI Standard Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate.

7 7 Weight Data Model No. Description Weight lbs. kg Net Weight LCA088S Net weight (base unit) LGA088S Net weight (base unit) LHA088S Net weight (base unit) Shipping Weights LCA088S Base unit LHA088S Base unit LGA088S Base unit with low fire heat exchanger LGA088S Base unit with high fire heat exchanger (add to base) 30 4 Optional Electric Heat Accessories Unit Model No. LCA088S LHA088S Electric Heat Model No. EHA (see Electric Heat Data tables for additional information) kw Range /230v - 2 hp (.5 kw) 56K93 56K95 460v - 2 hp (.5 kw) 56K52 25K09 With Power Exhaust ans 575v - 2 hp (.5 kw) 56K5 56K52 208/230-3 hp (2.2 kw) 56K93 56K96 460v - 3 hp (2.2 kw) 25K08 25K0 Unit use Block (3 phase) 575v - 3 hp (2.2 kw) 56K52 25K08 208/230v - 2 hp (.5 kw) 56K93 56K95 460v - 2 hp (.5 kw) 56K52 25K09 Without Power Exhaust 575v - 2 hp (.5 kw) 56K5 56K52 ans 208/230-3 hp (2.2 kw) 56K93 56K95 460v - 3 hp (2.2 kw) 56K52 25K09 575v - 3 hp (2.2 kw) 56K52 56K52 LTB2 ELECTRIC HEAT TERMINAL BLOCK LTB2-75 (30K75) 75 amps, LTB2-335 (30K76) 335 amps (Required for Units without Disconnect/Circuit Breaker but with Single Point Power Source) 7.5 kw *208/230v-3ph 2 hp (.5 kw) 3 hp (2.2 kw) 30K75 5 kw *208/230v-3ph 2 hp (.5 kw) 3 hp (2.2 kw) 30K75 LTB2 Terminal Block hp (.5 kw) 22.5 kw *208/230v-3ph phase 3 hp (2.2 kw) 30K75 30 kw *208/230v-3ph 2 hp (.5 kw) 3 hp (2.2 kw) 30K75 45 kw *208/230v-3ph 2 hp (.5 kw) 3 hp (2.2 kw) 30K75 30K76 *NOTE - All 460v and 575v unit voltages use LTB2-75 (30K75) Terminal Block.

8 888 LCA/LGA/LHA088 Electrical Data - LCA/LGA Models Model No. LCA/LGA088S Line voltage data - 60 hz - 3 phase 208/230v 460v 575v Compressors Rated load amps each (total) 2.2 (24.4) 7. (4.) 5.8 (.5) (2) Locked rotor amps each (total) 90 (80) 46 (92) 37 (74) Outdoor an ull load amps Locked rotor amps hp Output Indoor Blower kw ull load amps Locked rotor amps Rec. max. fuse With Exhaust an size (amps) Less Exhaust an *Minimum With Exhaust an Circuit Ampacity Less Exhaust an (No.) Horsepower (W) () /3 (249) Optional Power ull load amps Exhuast an Locked rotor amps Service Outlet (2) 5 volt G CI (amp rating) 5 *Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus and minus 0% of line voltage. NOTE - Where current does not exceed 00 amps, HACR type circuit breaker may be used in place of fuse. (U.S. only) Electrical Data - LHA Model Model No. LHA088S Line voltage data - 60 hz - 3 phase 208/230v 460v 575v Compressor Rated load amps () Locked rotor amps Outdoor an ull load amps3.5.2 Locked rotor amps hp Indoor Output kw Blower ull load amps Locked rotor amps Rec. max. With Exhaus t an fuse size (amps) Less Exhaust an *Minimum With Exhaus t an Circuit Ampacity Less Exhaust an Optional Power Exhuast an (No.) Horsepower (W) () /3 (249) ull load amps2.4.3 Locked rotor amps Service Outlet (2) 5 volt G CI (amp rating) 5 *Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. NOTE - Extremes of operating range are plus and minus 0% of line voltage. NOTE - Where current does not exceed 00 amps, HACR type circuit breaker may be used in place of fuse (U.S. only).

9 9 Optional Electric Heat Data - LHA Model kw Size Required Electric Heat Model No. & Net Weight No. of Steps Volts (Requires unit fuse block and terminal block) *Total Unit (with Power Exhaust an) & kw Btuh Electric Heat Minimum Circuit Ampacity Output 2 hp (.5 kw) 3 hp (2.2 kw) , , ,600 EHA , /230v (6L08) , kw 460v (6L09) , v (6L0) 3 lbs. (4 kg) , , , , , , ,00 EHA , /230v (6L) ,000 5 kw 460v (6L2) , v (6L3) 3 lbs. (4 kg) , , , , , , kw , EHA , /230v (32L95) , v (32L96) , v (32L97) 38 lbs. (7 kg) , , , , , , kw , EHA , /230v (6L4) , v (6L5) , v (6L6) 38 lbs. (7 kg) , , , , , , kw , EHA , /230v (6L7) , v (6L8) , v (6L9) 42 lbs. (9 kg) , , , ,600 *Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67º (75ºC) May be used with two stage control. NOTE - use block must be ordered extra. use block must be installed in unit with field installed heaters. Also requires LTB2 Te rminal Block.

10 00 LCA/LGA/LHA088 Optional Electric Heat Data - LCA Model kw Size Required Electric Heat Model No. & Net Weight No. of Steps Volts (Requires unit fuse block and terminal block) kw Btuh Output *Total Unit (with Power Exhaust an) & Electric Heat Minimum Circuit Ampacity 2 hp (.5 kw) 3 hp (2.2 kw) , , ,600 EHA , /230v (6L08) , kw 460v (6L09) , v (6L0) 3 lbs. (4 kg) , , , , , ,000 5 kw , EHA , /230v (6L) , v (6L2) , v (6L3) 3 lbs. (4 kg) , , , , , , , EHA , /230v (32L95) , kw 460v (32L96) , v (32L97) 38 lbs. (7 kg) , , , , *Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67º (75ºC) May be used with two stage control. NOTE - use block must be ordered extra. use block must be installed in unit with field installed heaters. Also requires LTB2 Terminal Block.

11 Optional Electric Heat Data - LCA Model kw Size Required Electric Heat Model No. & Net Weight No. of Steps Volts (Requires unit fuse block and terminal block) kw Btuh Output *Total Unit (with Power Exhaust an) & Electric Heat Minimum Circuit Ampacity 2 hp (.5 kw) 3 hp (2.2 kw) , , kw , EHA , /230v (6L4) , v (6L5) , v (6L6) 38 lbs. (7 kg) , , , , , , kw , EHA , /230v (6L7) , v (6L8) , v (6L9) 42 lbs. (9 kg) , , , ,600 *Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67º (75ºC) May be used with two stage control. NOTE - use block must be ordered extra. use block must be installed in unit with field installed heaters. Also requires LTB2 Terminal Block.

12 22 LCA/LGA/LHA088 Cooling Ratings LCA/LGA088 - One Compressor Operating Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 65º (8ºC) 75º (24ºC) 85º (29ºC) 95º (35ºC) Sensible to Sensible to Sensible to Total Total Total Total Ratio Comp. Total Ratio Comp. Total Ratio Comp. Cooling Cooling Cooling (S/T) (S/T) (S/T) Entering Sensible to Total Wet Comp. Total Ratio Cooling Bulb (S/T) cfm L/s Temp. kw Dry Bulb kw Dry Bulb kw Dry Bulb kw Dry Bulb 75º 80º 85º kbtuh kw 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC º (7ºC) º (9ºC) º (22ºC) LCA/LGA088 - All Compressors Operating Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 85º (29ºC) 95º (35ºC) 05º (4ºC) 5º (46ºC) Sensible to Sensible to Sensible to Total Total Total Total Ratio Comp. Total Ratio Comp. Total Ratio Comp. Cooling Cooling Cooling (S/T) (S/T) (S/T) Entering Sensible to Total Wet Comp. Total Ratio Cooling Bulb (S/T) cfm L/s Temp. kw Dry Bulb kw Dry Bulb kw Dry Bulb kw Dry Bulb 75º 80º 85º kbtuh kw 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC º (7ºC) º (9ºC) º (22ºC)

13 3 Cooling Ratings Full Load Cooling - LHA Model Total Air Volume Outdoor Air Temperature Entering Outdoor Coil 85º (29ºC) 95º (35ºC) 05º (4ºC) 5º (46ºC) Sensible to Sensible to Sensible to Total Total Total Total Ratio Comp. Total Ratio Comp. Total Ratio Comp. Cooling Cooling Cooling (S/T) (S/T) (S/T) Entering Sensible to Total Wet Comp. Total Ratio Cooling Bulb (S/T) cfm L/s Temp. kw Dry Bulb kw Dry Bulb kw Dry Bulb kw Dry Bulb 75º 80º 85º kbtuh kw 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC kbtuh kw 75º 80º 85º 24ºC 27ºC 29ºC º (7ºC) º (9ºC) º (22ºC) Heating - LHA Model Indoor Coil Air Volume 70º db (2ºC db) Air Temperature Entering Outdoor Coil 65º (8ºC) 45º (7ºC) 25º (-4ºC) 5º (-5ºC) -5º (-26ºC) Total Heating Comp. kw Total Heating Comp. kw Total Heating Comp. kw Total Heating Comp. kw Total Heating cfm L/s kbtuh kw kbtuh kw kbtuh kw kbtuh kw kbtuh kw Comp. kw

14 44 LCA/LGA/LHA088 Heating Performance - LHA Model at 3000 cfm (45 L/s) Indoor Coil Air Volume Outdoor Temperature Compressor Total Output º ºC kw kbtuh kw Blower Data - Base Unit FOR ALL UNITS ADD: Outdoor Temperature Compressor Total Output º ºC kw kbtuh kw *Bold Italics indicate field furnished drive - Wet indoor coil air resistance of selected unit 2 - Any factory installed options air resistance (heat section) 3 - Any field installed accessories air resistance (duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See page for wet coil and option/accessory air resistance data and blower motors and drives. MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT LCA/LHA requires 3000 cfm (45 L/s) minimum air with electric heat in horizontal applications. LCA/LHA requires 2600 cfm (225 L/s) minimum air with electric heat in donwflow applications. Air Volume cfm (L/s) 2000 (945) 2200 (040) 2400 (35) 2600 (230) 2800 (325) 3000 (420) 3200 (50) 3400 (605) 3600 (700) 3800 (795) 4000 (890) Total Static Pressure - Inches Water Gauge (Pa).20 (50).40 (00).60 (50).80 (200).00 (250).20 (300).40 (350).60 (400).80 (450) 2.00 (495) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP (kw) (kw) (kw) (kw) (kw) (kw) (kw).40 (.30).50 (.37).65 (.48).80 (.60).00 (.75).20 (.90).40 (.04).70 (.27).95 (.45) (.72) (.98) (kw).55 (.4).65 (.48).80 (.60).95 (.7).5 (.86).35 (.0).60 (.9) (.38) (.60) (.83) (2.3) (kw).70 (.52).80 (.60).95 (.7).0 (.82).30 (.97).50 (.2) (.3) (.53) (.75) (2.0) (2.28) (kw).90 (.67).00 (.75).5 (.86).30 (.97) (.2) (.27) (.45) (.68) (.90) (2.6) (2.46) (.82) (.90) (.0) (.2) (.27) (.45) (.64) (.87) (2.09) (2.35) (2.65) (.97) (.08) (.9) (.3) (.45) (.60) (.83) (2.0) (2.28) (2.54) (2.83) (.6) (.27) (.34) (.49) (.64) (.79) (.98) (2.20) (2.46) (2.72) (3.02) (.38) (.45) (.57) (.68) (.83) (.98) (2.20) (2.42) (2.65) (2.95) (3.2) (.64) (.68) (.79) (.90) (2.0) (2.20) (2.42) (2.6) (2.87) (3.7) (3.43) (.87) (.94) (2.0) (2.3) (2.28) (2.42) (2.6) (2.83) (3.0) (3.36) (3.66)

15 5 Factory Installed Drive Kit Specifications Outputs RPM Range Nominal hp Maximum hp Nominal kw Maximum kw Drive Drive 2 Drive 3 Drive 4 **2 Standard ** Standard *Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Armstrong are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. **Base unit. Field/Factory Installed Accessory Air Resistance Air Volume Total Resistance - Inches water gauge (Pa) Gas Heat Exchange (LGA Models) Wet Indoor Coil cfm L/s Low ire High ire Electric Heat Economizer (5).05 (2).08 (20).3.03 (7) (7).08 (20).3 (32).5.04 (0) (22).0 (25).6 (40).6.05 (2) (25).4 (35).23 (57).7.05 (2) (27).5 (37).25 (62).8.06 (5) (30).9 (47).32 (80) (5) (35).23 (57).39 (97) (7) (37).26 (65).43 (07) (20) (42).30 (75).50 (24) (22) (45).32 (80).53 (32).33.0 (25) (47).36 (90).60 (49).35. (27) Ceiling Diffuser Air Resistance Unit Size 088 Total Resistance - Inches water gauge (Pa) Air Volume RTD Step-Down Diffuser D lush Side 2 Ends All Ends & Sides cfm L/s 2 Ends Open Diffuser Open Open (52).8 (45).5 (37).4 (35) (60).2 (52).8 (45).7 (42) (67).24 (60).2 (52).20 (50) (80).29 (72).25 (62).25 (62) (02).37 (92).32 (80).3 (77) (24).45 (2).39 (97).37 (92) (52).54 (34).48 (9).44 (09) (82).63 (57).57 (42).5 (27)

16 66 LCA/LGA/LHA088 Power Exhaust Fans Performance Return Air System Static Pressure Air Volume Exhausted in. w.g. Pa cfm L/s Ceiling Diffuser Air Throw Data Model No. *Effective Throw Range Air Volume RTD Step- D lush Down cfm L/s ft. m ft. m *Throw is the horizontal or vertical distance an airstream travels on leaving the outlet or diffuser before the maximum velocity is reduced to 50 ft. (5 m) per minute. our sides open.

17 7 Guide Specifications General - Furnish and install single package air to air DX mechanical cooling system, complete with automatic controls. The single package unit shall be a standard product of a firm regularly engaged in the manufacture of heating-cooling equipment. The manufacturer shall have parts and service available throughout the U.S. and Canada. The manufacturer shall test operate system at the factory before shipment. Air Distribution - Equipment shall be capable of bottom (downflow) or side (horizontal) handling of conditioned air. Horizontal air shall require optional horizontal conversion kit. Approvals - All electrical components shall have E.T.L. and C.G.A. Listing. All wiring shall be in compliance with NEC and CEC. Equipment Warranty - Heat exchangers shall have a limited warranty for a full ten years (LGA Models).Compressors have a limited warranty for a full five years. All other components have a limited warranty for one year. Cooling System - The coils shall be nonferrous construction with aluminum fins mechanically bonded to durable copper tubes. Coils shall be pressure leak tested. Compressor shall be resiliently mounted, have overload protection and crankcase heater(s). The refrigeration system shall have discharge suction and liquid line service gauge ports, high pressure and low pressure switch(es) driers, defrost control(lha), freezestats, check and expansion valve(lha), reversing valve (LHA), accumulator (LHA) and full refrigerant charge. All models shall have low ambient operation down to 0 o F (-7.7 o C). All models shall be rated in accordance with ARI Standard 20/ (LCA/LGA) and ARI Standard (LHA). Heating System (LGA Model) - Tubular heat exchanger and inshot type gas burners shall be constructed of aluminized steel. Controls shall consist of direct spark ignition, electronic flame sensor controls, flame rollout switch, limit controls and automatic redundant dual gas valve with staging control and combustion air proving switch on induced draft blower. Units shall be available with LPG/Propane as an option. Heat exchanger shall be removable for servicing. Complete service access shall be provided for controls and wiring. Shall be E.T.L./C.G.A. design certified for outdoor installation. Cabinet - Shall be galvanized steel with a powdered enamel paint finish electrostatically bonded to the metal. Cabinet panels where conditioned air is handled shall be fully insulated to prevent sweating and minimize sound. Openings shall be provided for power connection entry. Indoor coil condensate drain extended outside cabinet shall be provided. Lifting holes shall be provided for rigging. Bottom power and gas (LGA) entry shall be provided. Service Access - Cabinet panels shall be hinged with tool-less access for compressor/heating/controls, blower and air filter/economizer compartments. Supply Air Blowers - Centrifugal supply air blower shall have ball bearings and adjustable belt drive. Blower assembly shall slide out of unit for servicing. mount base shall permit ease of motor changeover and belt tension adjustment. Blower wheel shall be statically and dynamically balanced. Outdoor Coil Fan - Direct drive propeller type outdoor coil fan shall discharge vertically and be direct driven by a hp (W) motor. Fan motor shall have ball bearings and be permanently lubricated and inherently protected. Fan shall have a safety guard. Air Filters - Disposable 2 inch (5 mm) thick pleated filters shall be furnished. Optional Accessories Additive Electric Heaters (LCA/LHA Models) - Electric heaters shall be available for field installation. Heating elements shall be nichrome bare wire exposed directly to the air stream. Time delays shall bring the elements on and off in sequence with a time delay between each element. Limit controls shall provide overload and short circuit protection. Ceiling Diffusers - Furnish and install a (flush or stepdown) optional combination ceiling supply and return air diffuser. Supply and return transitions shall be available, for field installation in the roof mounting frame, to provide duct connections to the diffuser. Coil Guards - Furnish and install galvanized steel coil guards. Dirty Filter Switch - Furnish and install pressure switch that indicates dirty filter. Economizer Section - Furnish and install economizer complete with recirculated air dampers, outside air dampers and controls. Low leakage dampers shall ride in nylon bearings. The economizer section shall provide for the introduction of outdoor air for minimum ventilation and free cooling. Integrated economizer control shall allow compressors to cycle for additional cooling, as needed. Damper actuator shall be opposing gear driven, 24 volt, fully modulating design. Plug-in control board (IMC) shall consist of adjustable minimum positioner, enthalpy setpoint and DIP switches for setting type of control log used. Economizer control options shall consist of sensible temperature, global, outdoor enthalpy and differential enthalpy (outdoor and return air). Optional outdoor air hood (required) with filters shall be galvanized steel with a powdered enamel paint finish electrostatically bonded to the metal. Economizer shall be available for field installation. Gravity Exhaust Dampers - Pressure operated dampers shall be available for field installation. Extruded aluminum dampers shall prevent blow-back and outdoor air infiltration during off cycle. Hail Guards - Furnish and install heavy gauge, painted steel hail guards. Horizontal Conversion Kit - Shall be available for all models to provide duct covers to block off unit down-flow supply air opening, horizontal return air opening panel (on unit) is moved to block off downflow return air opening for horizontal applications. Horizontal Gravity Exhaust Dampers - Pressure operated dampers shall be available for field installation in the return air duct. Extruded aluminum dampers shall prevent blow-back and outdoor air infiltration during off cycle. Indoor Air Quality Sensor - Furnish and field install sensor to monitor CO2 levels, relays information to Integrated Module Control (IMC) which adjusts economizer dampers proportionately to the pollutant level.

18 88 LCA/LGA/LHA088 Guide Specifications Disconnect - Furnish and factory install unit disconnect switch. Service Outlets - Furnish and factory install dual 5 volt, 5 amp GFCI type service outlets. Wiring shall be field provided. Outdoor Air Damper Section - Optional outdoor dampers shall be available to provide outdoor air requirements of up to 25%. Models shall be available for manual or automatic operation. Dampers shall be opposing gear driven design. ized damper section shall install internal to the unit. Optional outdoor air hood (required) with filters shall be galvanized steel with a powdered enamel paint finish electrostatically bonded to the metal. Dampers shall be available for field installation. Power Exhaust Fan - Shall be available for all models with economizer (down-flow applications only). Direct drive propeller type fan shall exhaust air through optional gravity exhaust damper (required). shall be overload protected. Fan shall be field installed between economizer and gravity exhaust dampers. Roof Mounting Frame - Furnish and install a steel roof mounting frame for bottom discharge and return air duct connection. It shall mate to the bottom perimeter of the equipment. When flashed into the roof it shall make a unit mounting curb and provide weatherproof duct connection and entry into the conditioned air. Flashing shall be the responsibility of the roofing contractor. Frame shall be approved by U.S. National Roofing Contractors Association. Smoke Detectors - Furnish and field install photoelectric type smoke detector in either or both return air section and supply air section. Terminal Block (LCA/LHA Models) - Shall be required for units without disconnect switch but with single point power supply and electric heat. Unit Fuse Block (LCA/LHA Models) - Shall be required for units with single point power supply and electric heat.

19 9 Dimensions - LCA Model - inches (mm) Shown with Optional Economizer Dampers, Power Exhaust Fans, Convenience Outlet, Unit Disconnect Corner Weights - lbs. (kg) Center of Gravity - inches (mm) Model No. AA BB CC DD lbs. kg lbs. kg lbs. kg lbs. kg LCA088 Base Unit LCA088 Max. Unit Base Unit - The standard unit with NO OPTIONS. Max. Unit - The standard unit with ALL OPTIONS installed. (Economizer, Power Exhaust ans, High Heating & Controls) Model No. EE inch mm inch mm LCA088 Base Unit 43 / /2 546 LCA088 Max. Unit 42 / Base Unit - The standard unit with NO OPTIONS. Max. Unit - The standard unit with ALL OPTIONS installed. (Economizer, Power Exhaust ans, High Heating & Controls)

20 2020 LCA/LGA/LHA088 Dimensions - LGA Model - inches (mm) Shown with Optional Economizer Dampers, Power Exhaust Fans, Convenience Outlet, Unit Disconnect Corner Weights - lbs. (kg) Model No. AA BB CC DD lbs. kg lbs. kg lbs. kg lbs. kg LGA088 Base Unit LGA088 Max. Unit Base Unit - The standard unit with NO OPTIONS. Max. Unit - The standard unit with ALL OPTIONS installed. (Economizer, Power Exhaust ans, High Heating & Controls) Center of Gravity - inches (mm) Model No. EE inch mm inch mm LGA088 Base Unit 43 / /2 546 LGA088 Max. Unit 42 / Base Unit - The standard unit with NO OPTIONS. Max. Unit - The standard unit with ALL OPTIONS installed. (Economizer, Power Exhaust ans, High Heating & Controls)

21 2 Dimensions - LHA Model - inches (mm) Shown with Optional Economizer Dampers, Power Exhaust Fans, Convenience Outlet, Unit Disconnect Corner Weights - lbs. (kg) Center of Gravity - inches (mm) AA BB CC DD Model No. lbs. kg lbs. kg lbs. kg lbs. kg LHA088 Base Unit LHA088 Max. Unit Base Unit - The standard unit with NO OPTIONS. Max. Unit - The standard unit with ALL OPTIONS installed. (Economizer, Power Exhaust ans, High Heating & Controls) Model No. EE inch mm inch mm LHA088 Base Unit 43 / /2 546 LHA088 Max. Unit 42 / Base Unit - The standard unit with NO OPTIONS. Max. Unit - The standard unit with ALL OPTIONS installed. (Economizer, Power Exhaust ans, High Heating & Controls)

22 2222 LCA/LGA/LHA088 Accessory Dimensions - inches (mm) LARMF08/0 - Roof Mounting Frame (Double Duct Opening) LARMF08/0 - Roof Mounting Frame with LASRT08/0 Transition Roof Mounting Frame Specifications Roof mounting frame is rigid enough to be spanned over its entire length or cantilevered if supported on both sides of center of gravity. Roof Mounting rame LARM 08/0-4 LARM 08/0-24 *Moment of Inertia (l) (in. 4 ) (cm 4 ) 39 (634) 60 (6639) *Section modulus l/c (in. 3 ) (cm 3 ) 5.5 (90) 3. (52) rame weight (lb/ft) (kg/m) of length 5.5 (8.2) 8.5 (2.7) Design strength (psi) (kpa) 20,000 (37,900) *Includes both sides of frame.

23 23 Accessory Dimensions - inches (mm) Combination Ceiling Supply and Return Diffusers LAGEDH03/5 Horizontal Gravity Exhaust Dampers (Field installed in return air duct) Installation Clearances - inches (mm) Optional Outdoor Air Hood 36 (94) 36 (94) Blower 36 (94) 36 (94) NOTE - Top Clearance Unobstructed. NOTE - Entire perimeter of unit base require support when elevated above mounting surface. Minimum Clearance To Combustible Materials

24 All specifications are subject to change without notice. Armstrong Air Conditioning Inc. A Lennox International Inc. Company 42 Monroe Street Bellevue, OH 448 (49) Form #LCA-LGA-LHA (6/0) Armstrong Air Conditioning Inc. 200 Printed in U.S.A. *LCA-LGA-LHA *

Packaged L Series LCA/LGA/LHA

Packaged L Series LCA/LGA/LHA Packaged L Series LCA/LGA/LHA 80, 0, 40 & 300S Models LCA/LGA 5-5 Ton LHA 5 & 0 Ton 60,000-470,000 Btuh Gas Heating Cap. 88,000-0,000 Heat Pump Heating Cap. 38,600-307,00 Btuh Optional Electric Heat GUK

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Packaged L Series LCA/LCC GUK

Packaged L Series LCA/LCC GUK Packaged L Series LCA/LCC 090, 102, 1 & 150 Models 7 1/2 to 12 Tons 7.5 to Optional Electric Heat GUK FEATURES Down flow or horizontal supply and return configuration E.T.L. and CSA listed, efficiency

More information

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C

ROOFTOP UNITS 60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C E N G I N E E R I N G D A T A P A C K A G E D E L E C T R I C / E L E C T R I C tc ROOFTOP UNITS 60 HZ Bulletin No. TCA090 102 120 150 (08/09) ASHRAE 90.1 COMPLIANT 7.5 to 12 Tons Net 90,000 140,000 Btuh

More information

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature

TCA WARNING CAUTION. TCA 15 through 25 ton ROOFTOP UNITS. Service Literature TCA ROOFTOP UNITS Service Literature TCA 180 210 240 300 (10 08) The TCA180S, 180H, 210S, 210H, 240S, 240H and 300S are available in one cabinet size with cooling capacities from 180,000 to 286,000 Btuh

More information

Z-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED HEAT PUMPS ZH Z-Series Rooftop Units 60 HZ Bulletin No. ZHA-036-060 (0/03) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT 3 to 5 Tons Net Cooling Capacity 36,00 to 58,000

More information

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C P A C K A G E D E L E C T R I C / E L E C T R I C 2SA13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210454 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity

More information

SERIES GCS PACKAGED UNITS COOLING & GAS HEAT

SERIES GCS PACKAGED UNITS COOLING & GAS HEAT ENGINEERING DATA SERIES GCS24-1853-2553-2753-3003 PACKAGED UNITS COOLING & GAS HEAT *177,000 to 280,000 Btuh (51.9 to 82.0 kw) 145,000 to 470,000 Btuh (42.5 to 137.7 kw) Input Heating *ARI Standard Ratings

More information

Z-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZC Z-Series Rooftop Units 60 HZ Bulletin No. ZCA-06-060 (0/0) MODEL NUMBER IDENTIFICATION to 5 Tons Net Cooling Capacity 4,600 to 57,000 Btuh Optional

More information

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P E N G I N E E R I N G D A T A P A C K A G E D H E A T P U M P TH ROOFTOP UNITS 60 HZ Bulletin No. THA024 030 036 048 060 (08/09) ASHRAE 90.1 COMPLIANT 2 to 6 Tons Net 24,000 to 71,000 Btuh Net Heating

More information

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C P A C K A G E D G A S / E L E C T R I C 2SG13 60HZ E N G I N E E R I N G D A T A Bulletin No. 210453 August 06 Supersedes July 06 MODEL NUMBER IDENTIFICATION SEER 13.00 2 to 2.5 Tons Capacity 23,000 to

More information

ZHA/ZHB SERIES WARNING

ZHA/ZHB SERIES WARNING Service Literature Corp. 09-L Revised 7-08 ZHA/ZHB SERIES, 4, 5 and 6 ton 0.6 to kw ZHA/ZHB06, 048, 060, 07 The ZHA/ZHB packaged electric heat pump units are available in standard cooling efficiency (06S,

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007

T CLASS ROOFTOP UNITS 60 HZ Bulletin No July 2008 Supersedes August 2007 E N G I N E E R I N G D A T A P A C K A G E D G A S / E L E C T R I C TG T CLASS ROOFTOP UNITS 60 HZ Bulletin No. 210392 July 2008 Supersedes August 2007 MODEL NUMBER IDENTIFICATION ASHRAE 90.1 COMPLIANT

More information

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6) ENGINEERING DT PCKGED HET PUMPS CHP16 024 030 036 048 060 CHP20 036 048 060 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 23,800 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 23,800 to 56,000

More information

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw

ZCA. Raider Rooftop Units 60 HZ. ASHRAE 90.1 COMPLIANT 3 to 6 Tons Net Cooling Capacity 34,600 to 68,000 Btuh Optional Electric Heat - 5 to 30 kw PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZCA Raider Rooftop Units 60 HZ Bulletin No. 0748 November 07 Supersedes June 07 Value Without Compromise MODEL NUMBER IDENTIFICATION Z C A 060 S 4 B N

More information

13 GCS X A X Nominal SEER Minor Revision Number

13 GCS X A X Nominal SEER Minor Revision Number PA C KA G E D G A S / E L E C T R I C 13GCSX ELITE SERIES Residential - R-410A P R O D U C T S P E C I F I C AT I O N S Bulletin No. 210422 April 2013 Supersedes June 2012 SEER - 13.00 AFUE - 80% 2 to

More information

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1 These 7½ and 10 ton units are designed specifically

More information

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity

More information

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SE Series Single Packaged Heat Pump, Single Phase Q6SE-14 SEER, 8.0 HSPF 2-5 Ton Units Cooling: 23,000 to 58,000 Btuh Heating: 22,800 to 59,000 Btuh The Q6 Series single packaged

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

Z-Series Rooftop Units 60 HZ

Z-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED GAS/electric ZG Z-Series Rooftop Units 60 HZ Bulletin No. ZGA-036-060 (02/203) MODEL NUMBER IDENTIFICATION Brand/Family Z = Z-Series Unit Type G = Packaged Gas Heat w/ Electric

More information

T CLASS ROOFTOP UNITS 60 HZ

T CLASS ROOFTOP UNITS 60 HZ E N G I N E E R I N G D A T A P A C K A G E D G A S / E L E C T R I C TG T CLASS ROOFTOP UNITS 60 HZ Bulletin No. 210444 July 2008 Supersedes February 2008 ASHRAE 90.1 COMPLIANT 2 to 6 Tons Net 23,400

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents

TCA WARNING CAUTION ROOFTOP UNITS. Service Literature. Table of Contents TCA ROOFTOP UNITS Service Literature TCA 024 030 036 048 060 072 (10 08) The TCA packaged electric cooling units are available in basic cooling efficiency (036B, 048B and 060B) and standard cooling efficiency

More information

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGAA SERIES 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGAA SERIES 10 SEER C CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained for year-round comfort. Systems

More information

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components AFGP12B Gas/Electric Package Unit Features Shipped for horizontal applications; easily converted to downshot Side-by-side horizontal discharge Standard thermostatic expansion valve Crimp-Tite weld-free

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No

PGMD Series 10 SEER. International Comfort Products 651 Heil Quaker Avenue Lewisburg, Tn Part No PGMD Series 10 SEER PACKAGE COOLING 1-1/2THRU5TONSINGLEPHASE CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Efficiency: PGAA - 10 SEER. Combination gas heating and electric cooling, self-contained

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

ASHRAE 90.1 COMPLIANT

ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS/electric ZGB Raider Rooftop Units 60 HZ Bulletin No. 0795 November 07 Value Without Compromise MODEL NUMBER IDENTIFICATION Brand/Family Z = Raider Product Line Unit

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

TCA SERIES CAUTION. Service Literature TCA090/150 SERIES. 7.5 to 12.5 ton 26.3 kw to 44 kw. Table of Contents

TCA SERIES CAUTION. Service Literature TCA090/150 SERIES. 7.5 to 12.5 ton 26.3 kw to 44 kw. Table of Contents Service Literature Corp. 0411 L3 Revised 06 2005 TCA090/150 SERIES TCA SERIES 7.5 to 12.5 ton 26.3 kw to 44 kw The TCA 7.5, 8.5 and 10 ton cooling package units are available in standard efficiency (090S,

More information

Z-Series Rooftop Units 50 HZ

Z-Series Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric ZH Z-Series Rooftop Units 50 HZ Bulletin No. ZHA-036-060-50HZ (05/207) 0.5 to 2.0 kw (3 to 6 Tons) Net ing 9. to 7.3 kw (3 200 to 59 000 Btuh) Net 8.5

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ P R O D U C T S P E C I F I C AT I O N S P A C K A G E D H E A T P U M P KH Landmark Rooftop Units 50 HZ Bulletin No. 49049 March 202 Supersedes November 20 52.8 and 70.3 kw (5 and 20 Tons) Net Cooling

More information

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GP Series 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A 11.2 EER Commercial System These units are designed specifically for retrofit applications and compatibility

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ PRODUCT SPECIFICATIONS PACKAGED ELECTRIC/electric KC Landmark Rooftop Units 50 HZ Bulletin No. 490 June 0 Supersedes September 0 0.5 to 6.4 kw (3 to 7.5 Tons) Net Cooling Capacity 9.5 to 3.7 kw (3 400

More information

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY TECHNICAL SPECIFICATIONS R6GN Series Single Packaged Gas/Electric Units with R-410A R6GN 10.8 EER Commercial System 12½ and 15 Ton Units These units offer flexibility in the replacement market. The 12½

More information

FEATURES AND BENEFITS

FEATURES AND BENEFITS PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP zh Rooftop Units 50 HZ Bulletin No. ZHA-092-20 (3/205) 26 to 35 kw Net ing Capacity 22.6 to 30.6 kw (77 00 to 04 600 Btuh) Net Heating Capacity 23.6 to 29.0 kw

More information

ASHRAE 90.1 COMPLIANT

ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS/electric ZGA Raider Rooftop Units 60 HZ Bulletin No. 20747 November 207 Supersedes June 207 Value Without Compromise MODEL NUMBER IDENTIFICATION Brand/Family Z = Raider

More information

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER) 511.06-TG3Y (0600) SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS B1CH 1 & 40 15 and 0 NOMINAL TONS (8.5-8.8 EER) SUNLINE 000 DESCRIPTION York Sunline 000 Heat Pumps are convertible single package units. All

More information

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON 14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON Two -Stage Gas Heating/Two -Stage Electric Cooling REFRIGERATION CIRCUIT All models are equipped with high efficiency two--stage Copeland UltraTech

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

HS22 Bulletin # November 1992 Supersedes September 1990

HS22 Bulletin # November 1992 Supersedes September 1990 ENGINEERING DATA CANADIAN EDITION FEATURES Application The HS22 series condensing units feature extra high efficiency with minimum operating sound levels. Units have seasonal energy efficiency ratings

More information

Z-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT

Z-Series Rooftop Units 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC ZG Z-Series Rooftop Units 60 HZ Bulletin No. ZGA/ZGB-092-50 (8/208) MODEL NUMBER IDENTIFICATION Brand/Family Z = Z Series Unit Type G = Packaged Gas Heat w/

More information

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh

13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh PGF3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT (3 Phase) 35 to 53 MBtuh REFRIGERATION CIRCUIT All models are equipped with high efficiency Copeland scroll compressor, 4 & 5 ton have two--stage

More information

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower TECHNICAL SPECIFICATIONS R6GF Series Rev B Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower R6GF 15 SEER, 81% AFUE 2-5 Ton Units These single packaged gas/electric systems

More information

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES UNITARY AIR-CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI THREE PHASE EQUIPMENT STANDARD 210 Rated in accordance with ARI Standard Listed By 240. Certification applies only

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS

SUNLINE 2000 TM TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS TECHNICAL GUIDE SUNLINE 2000 TM SINGLE PACKAGE AIR-TO-AIR HEAT PUMPS MODELS B2CH 180 & B1CH 240 15 & 20 NOMINAL TONS 9.9-8.8 EER DESCRIPTION York Sunline 2000 Heat Pumps are convertible single package

More information

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units

GP4SN Series TECHNICAL SPECIFICATIONS. Single Packaged Electric Cooling Units. P4SN 10.3 EER Commercial System 7½ and 10 Ton Units TECHNICAL SPECIFICATIONS GP4SN Series Single Packaged Electric Cooling Units P4SN 10.3 EER Commercial System 7½ and 10 Ton Units These 7½ and 10 ton units are designed specifically for retrofit applications

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

K-Series Rooftop Units 60 HZ

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS PACKAGED GAS ELECTRIC KG K-Series Rooftop Units 60 HZ Bulletin No. KGA-80-00 (6/0) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT to 5 Tons Net Cooling Capacity 5,000 to 70,000

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance

More information

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

MERIT Series R-410A - Upflow / Horizontal - Variable Speed PRODUCT SPECIFICATIONS AIR HANDLERS CBX5UHV (-01) MERIT Series R-10A - Upflow / Horizontal - Variable Bulletin No. 10611 March 015 Supersedes November 01 MODEL NUMBER IDENTIFICATION CB X 5 UH V - 00-0

More information

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

V33B High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Landmark Rooftop Units 50 HZ

Landmark Rooftop Units 50 HZ P R O D U C T S P E C I F I C AT I O N S P A C K A G E D H E A T P U M P KH Landmark Rooftop Units 50 HZ Bulletin No. 49048 November 200 Supersedes August 200 26 to 44 kw Net Cooling 23.6 to 36.5 kw (80

More information

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

DF6SF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS DF6SF Series Rev B Two-Stage Heat/Two-Stage Cool with Variable Speed Blower ihybrid Dual Fuel Package Units DF6SF 15 SEER, 81% AFUE, 8.0 HSPF 2 Ton thru 5 Ton Units These dual

More information

PACKAGE AIR CONDITIONERS

PACKAGE AIR CONDITIONERS PACKAGE AIR CONDITIONERS FORM NO. S22-92 REV. 2 Supersedes Form No. S22-92 Rev. RLNA- SUPER HIGH EFFICIENCY SERIES NOMINAL SIZES -5 TONS [0.6-7.6 kw] *Unit shown with optional louver panels installed..0

More information

SUNLINE 2000 (WORLD 50 HZ)

SUNLINE 2000 (WORLD 50 HZ) 530.26-TG1YI (298) SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D3CE 036, 048, 060 & 076 D5CG 036, 048, 060 & 076 3, 4, 5 AND 6 NOMINAL TONS SHOWN SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION YORK Sunline 2000

More information

LCA088 (Cooling & Electric Heat) Field Wiring... Page 15 Factory Installed Only Options... Page 4

LCA088 (Cooling & Electric Heat) Field Wiring... Page 15 Factory Installed Only Options... Page 4 ENGINEERING DATA 088 and 100 MODELS LCA PACKAGED COOLING & ELECTRIC HEAT LGA PACKAGED COOLING & GAS HEAT LHA PACKAGED HEAT PUMP *Net Capacity - 85,000 to 94,000 Btuh (24.9 to 27.5 ) Gas Input Heating Capacity

More information

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS R8HE Series Rev A Single-Phase and Three-Phase 95% AFUE Condensing Exchanger offering Two-Stage ing and 14 SEER Single-Stage Cooling with ECM Blower These single packaged gas/electric

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS AIR CONDITIONERS ELS T-SERIES COMMERCIAL SPLIT SYSTEMS R-40A - 60 HZ Bulletin No. ELS-072-240 (2/208) P R O D U C T S P E C I F I C AT I O N S 072-090 Models 80-240 Models EER up to 2.0 6 to 20 Tons Cooling

More information

PHB SERIES 7-1/2 and 10 TON

PHB SERIES 7-1/2 and 10 TON PHB SERIES 7-1/2 and 10 TON COMMERCIAL SINGLE PACKAGE HEAT PUMPS COMMERCIAL PACKAGE HEAT PUMP FEATURES Representative photo only, some models may vary in appearance. Rated in accordance with ARI Standard

More information

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES 530.18-TGY (598) SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D3CE/D3CG10 & D4CE/D4CG090, 10 & 150 7-1/, 8-1/, 10 AND 1-1/ NOMINAL TONS 8.5-9.0 EER DCG MODEL SHOWN SUNLINE 000

More information

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013)

K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA (5/2013) PACKAGED GAS/electric KG K-Series Rooftop Units 60 HZ PRODUCT SPECIFICATIONS Bulletin No. KGA-04-090 (5/03) MODEL NUMBER IDENTIFICATION Brand/Family K = K Series Product Line Unit Type G = Packaged Gas

More information

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units TM TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that

More information

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT

K-Series Rooftop Units Standard Efficiency - 60 HZ ASHRAE 90.1 COMPLIANT PRODUCT SPECIFICATIONS PACKAGED HEAT PUMP KHA K-Series Rooftop Units Standard Efficiency - 60 HZ Bulletin No. KHA-036-07 (/07) MODEL NUMBER IDENTIFICATION ASHRAE 90. COMPLIANT 3 to 6 Tons Net Cooling Capacity

More information

SINGLE PACKAGE HEAT PUMPS

SINGLE PACKAGE HEAT PUMPS SINGLE PACKAGE HEAT PUMPS HPP024 THRU 060 2 THRU 5 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These packaged heat pumps are designed for outdoor installation. Only utility and duct connections

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P6SD Series Single Packaged Air Conditioning, 13 SEER 3, 4, 5 Ton Units The P6 Series single packaged air conditioners are high efficiency self contained cooling units that can

More information

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP

PHF SERIES. THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP PHF SERIES THREE PHASE 50 Hz OPERATION CONVERTIBLE SINGLE PACKAGE HEAT PUMP 400v- 3-50 Hz FOR EXPORT USE Combination heating and cooling, self-contained for year-round comfort. Systems install on rooftop

More information

T-Class Split System Units R-410A - 50 HZ

T-Class Split System Units R-410A - 50 HZ E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S TS T-Class Split System Units R-40A - 50 HZ Bulletin No. 49035 February 200 Supersedes October 2009 MODEL NUMBER IDENTIFICATION Nominal Capacity

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

S/T Ratio. Input BTU/h

S/T Ratio. Input BTU/h SOUND REFRIGERANT ENVIRONMENTALLY PGD3 Product Specifications 13 SEER PACKAGE GAS / ELECTRIC UNIT, 2½ to 5 TONS 3 Phase, 208/230 3 60 and 460 3 60 REFRIGERATION CIRCUIT Environmentally sound R-410A refrigerant

More information

PCB COMMERCIAL SERIES

PCB COMMERCIAL SERIES PCB COMMERCIAL SERIES 50 Hz SELF-CONTAINED PACKAGE CONDITIONER 7½, 0, AND 5 TON [6.4 kw to 5.8 kw] COOLING CAPACITY: 90,000 TO 80,000 BTU/H The PCB Commercial 50 Hz self-contained packaged air conditioner

More information

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M AIR CONDITIONERS ELS ELITE COMMERCIAL SPLIT SYSTEMS R-40A - 50 HZ Bulletin No. 49073 March 208 P R O D U C T S P E C I F I C AT I O N S Supersedes February 208 072-090 Models 80-240 Models 2 to 70 kw ing

More information

RGMA Series Package Gas Electric SPECIFICATIONS

RGMA Series Package Gas Electric SPECIFICATIONS RGMA Series Package Gas Electric SPECIFICATIONS CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC COMMERCIAL GAS/ELECTRIC UNIT FEATURES EFFICIENCY 7-1/2 thru 20 ton Cooling, 200,000 thru 270,000 BTUH Heating SINGLE

More information

CHP20R Basic Unit CHP

CHP20R Basic Unit CHP ENGINEERING DT PCKGED HET PUMPS CHP20R ELITE SERIES RESIDENTIL 2 to 5 Ton (7.0 to 17.6 ) SEER up to 12.65 Net Capacity 24,000 to 59,000 Btuh (7.0 to 17.3 ) Heating Capacity 24,200 to 56,000 (7.1 to 16.4

More information

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units TM TECHNICAL SPECIFICATIONS P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units The P4 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units TECHNICAL SPECIFICATIONS P8SE Series 14 SEER, Three Phase Packaged Air Conditioner 3, 4, 5 Ton Units The P8 Series single packaged air conditioners are high efficiency self contained cooling units that

More information

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Submittal Data Form Job Name DCG Series 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE Cooling Capacity: 88,000 144,000 BTU/h Heating Capacity (Output): 168,000 BTU/h Purchaser Order No.

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS Q6SD Series 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units The Q6SD Series packaged units are high efficiency self contained cooling and heating units that can

More information

T A A 120 S 4 D - 1 M

T A A 120 S 4 D - 1 M PRODUCT SPECIFICATIONS AIR HANDLERS TA T-CLASS SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 50 HZ Bulletin No. 490133 February 2013 Supersedes December 2010 180-240 Models 072-090-120-150 Models Noal

More information

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower E N G I N E E R I N G D A T A A I R H A N D L E R S C31MV DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable lower ulletin No. 210107 July 2007 Supersedes January 2007 Nominal Capacity 3 to 5 Tons

More information

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h CPC Commercial 15- & 20-Ton, Three-Phase Packaged Air Conditioner 15-Ton Cooling Capacity: 180,000 BTU/h 20-Ton Cooling Capacity: 240,000 BTU/h Contents Nomenclature...2 Product Features...3 Product Specifications...4

More information

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER DTC Series Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: Cabinet Features

More information

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY

R6GD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units WARRANTY TECHNICAL SPECIFICATIONS R6GD Series 13 SEER, Three Phase, Packaged Gas/ Electric Units with R-410A 3-5 Ton Units The R6GD Series packaged gas/electrics are high efficiency self contained cooling units

More information

*ARI Standard Ratings

*ARI Standard Ratings ENGINEERING DT SERIES GCS24-953-1353-1603-3003 PCKGED UNITS COOLING & GS HET *88,000, 119,000, 144,000 & 289,000 Btuh (25.8, 34.9, 42.2 & 84.7 kw) 126,000 to 470,000 Btuh (36.9 to 137.7 kw) Input Heating

More information

VHIA High-Static Ducted Indoor Units - 60HZ

VHIA High-Static Ducted Indoor Units - 60HZ PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage