HBDBM High Bay Series

Similar documents
High Bay Luminaire Series

HBDB High Bay Fixture with Occupancy Sensor

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

LED UFO High Bay with j-box Installation Instruction

Operation/Installation Instructions

Operating Instructions

I. Pendant Mount Installation

Installation and Maintenance Manual (2014)

Elle Surface Mounting Instructions

When using electrical equipment, basic safety precautions should always be followed including the following:

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

ECO-T LED RECESSED TROFFER USER MANUAL

Elle Surface Mounting Instructions

The installation must only be performed by a licensed electrician. Disconnect power before installing the product or servicing it.

GE Lighting. Heavy Industrial High Bay & Low Bay Lighting. (ABR1 - Series) imagination at work

Circa Ambient Interior Luminaire

Installation Instruction

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

PGA Parking Garage Luminaire

WARRANTY & LISTINGS IP65 DIMENSIONS. Example: PLEDHBR-14-4K-PRM-BLK-UNV-OS + LEDHBRSN-PSH-PRM-V2 + MWAVEDHS-REM ORDERING INFORMATION.

Installation Instructions MX LED Enhanced Color Adjustable

NT-300 Series Single Circuit Track System & Accessories

Surface Mount Explosion Proof, Waterproof Fluorescent Lights - T12 Very High Output - Oil Rigs - 2 L

CFP-LED Contractor Select Flat Panel. Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

PROJECT INFORMATION. Catalog No.

INSTALLATION INSTRUCTIONS

L1EPH ECONO LED HIGH BAY LUMINAIRE FEATURES AND SPECIFICATIONS MOUNTING OPTIONS & ACCESSORIES OVERVIEW

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Operating Instructions

MEDMASTER DOWNLIGHT Luminaires for Surgical Applications

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

PDMHB Watt LED I-Beam High Bay

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

CLARA CLA SUSPENDED, WALL, SURFACE

Installation Instructions 4 Gravity Enhanced Color Adjustable

Installation Instructions: Eco Linear High Bay

LEDHBR-PRM Premium Round LED High Bay 14,000-32,000 Lumens FEATURES. Input Voltage

Lumination TM LED Luminaires LAL Series - Continuous Run Option

LED CANOPY with j-box

IHB Series High Bay LEDs

12 Watt LED Signal Light - Colored LED Warning Light - NEMA 4X - Audible Horn

LHBC Commercial-Grade High or Low Bay Luminaire

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

ExceLine 1611 Clovis R. Barker Road San Marcos, TX Fax: PT#: EXSP038A0712

LED IMPORTANT SAFETY INSTRUCTIONS

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

MaxLite LED Linear HighBay Fixtures

Spun Bay Installation Standard Version (non dimmable), Hook Mount

PIPELINE 1 SUSPENSION UP OR DOWN WITH POWER - END FEED

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

LED Parking Garage. Optional motion sensor

EcoSystem Multiple Control Input Ballasts

INSTALLATION INSTRUCTIONS

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Lighting Systems Argus-7

Input Voltage: AC: VAC HC: VAC (50/60Hz) Electrical Ratings: WIDE FROSTED MODEL

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

LED Utility Wrap Fixture

INSTALLATION INSTRUCTION MANUAL

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

Luminaires - LED High Bay

Phuzion LED High Bay Wet location listed

45 Degree Surface Mount Explosion Proof, Waterproof Fluorescent Lights -Paint Booth, Rigs - 2 Lamp

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

LED lighting system. We Brighten Your Brands.

GLASS ACT SINGLE RPD14 SUSPENDED, WALL, SURFACE

LED HIGH BAY - SL STANDARD LIFE BENEFITS APPLICATIONS MARKETS

HAZARDOUS LOCATION STREET LIGHT SLA SERIES INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION W Track Suspension system

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

LED HIGH BAY - SL 150W 200W BENEFITS APPLICATIONS MARKETS

ELMGR Compact Fluorescent Series Element Rodded Metal over Glass (glass lined) High Bay

LB - LIGHTING BUSWAY 25-40A

MODELS 2 & 4 Top Conduit Linears

Big Ass Light High Powered Fixture

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

LAD6 6 LED Architectural Downlight

Lumination TM LED Luminaire LUR Series

Install Guide PMX SERIES PENDANT MOUNTED MATRIX SP1 STYLE

LED HIGH BAY - EXT EXTENDED LIFE BENEFITS APPLICATIONS MARKETS

General Installation Instructions LED

id + 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

Operating Instructions

SAVE THESE INSTRUCTIONS

SloanLED THINLED. Constant Current. Installation Guide

LAD8 8 LED Architectural Downlight

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

LIGHTPLANE 1 RECESSED - LP1R

PG Series. Our PG Series has now been expanded to complete your entire site needs. With added housing shapes of round and square we offer

HP-2 / HP-6 Direct Installation Instructions Overview

LED Area Light. scratch that. This is the fixture of choice for all of our dealerships. Contact Us:

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

HID/AREA: NEC/CEC EXPLOSIONPROOF. Applications. NEC/CEC Certifications and Compliances

Transcription:

HBDBM High Bay Series INSTALLATION INSTRUCTIONS The High Bay Luminaire is ideal for installations with mounting heights over 25 feet. The fixture can be mounted with a hook or pendant with flexible adjustments to create uniform light from fixture to fixture. WARNING: This product must be installed in accordance with applicable local, state, and national electrical codes by a licensed person familiar with the construction and operation of the product and hazards involved. This luminaire must be adequately grounded for protection against shock hazards and to assure proper operation. Disconnect power before servicing. Suspend from adequate structure that can safely support the fixture. MIN 90 C SUPPLY CONDUCTORS Do not operate in ambient temperatures above those indicated on the luminaire Label. Make sure the supply voltage is within the voltage range stated on the Label Use only UL or IEC approved wire for input/output connections. Minimum size 18 AWG. General: Provide at least 12 of clearance from the top of the fixture to any ceiling or surface above. HOOK MOUNT INSTALLATION: 1. To pre-assemble hook and hub. Make sure to fix anti-rotation M4 screw. 1

2. The Weight of High Bay fixture is approximately 19.8 lbs with the base configuration. Ensure the structure and the suspending cable/chain are suitable for the weight of the fixture. 3. To make electrical connections, attach the lead wires according to the colors below. White wire connects to Neutral. 4. The fixture should already be factory set for correct balance. If additional balancing is necessary, make corrections using the adjustment screws in the locations shown below. Make sure to tighten the screws after adjustment. Adjustment screws 2

PENDANT MOUNT INSTALLATION: The fixture mounting receiver is threaded for 3/4 NPT pipe. 1. Feed the power cable through the conduit, and into the junction box. Attach the fixture to the conduit. 2. Insert set screw in order to secure the fixture to the Pipe. 3

3. The fixture should already be factory set for correct balance and orientation. If adjusting balance or orientation is necessary, make corrections using the adjustment screws in the locations shown, and tighten all screws after adjustment. Adjustment screws 4. Make wire connections inside the junction box according to the following color wires : White wire connects to Neutral. 4

WALL MOUNT INSTALLATION 1. Assemble the bracket on to the luminaire. Use screws and washers to fix the luminaire on the structure. Suggest to use 3/8 (M10) Screw and T 2.0 min washer. Bracket 2. Loosen the M10 and M4 screw, and rotate the luminaire to the desired direction. Tighten all screws. Torque Suggestion: M10 M10: 18 ft-lbs (245 Kgf.cm) M4: 1 ft-lbs (14 Kgf.cm) M4 3. Connect power cable conductors as follows: White wire connects to Neutral 5

AIRCRAFT CABLE INSTALLATION: 1. Aircraft cable assemblies to the luminaire with two aircraft cable assembly as shown below Notes: a. The assembly location must be shown below b. Do not exceeded angle greater than a 30 between the cables and the gravity line 30º Max 6

2. Connect power cable conductors as follows: White wire connects to Neutral SAFETY CABLE INSTALLATION: 1. Attach one end of the included safety cable through the hole between the fins on the luminaire. Ensure the safety cable is secured on the fixture. 2. Secure the other end of the safety cable to the mounting structure. 1~10V DIMMING INSTALLATION Dimming is controlled by 1~10VDC dimming signal (to be provided by others). A 10V Signal is about 100% lumen output A 1 V Signal is about 10% lumen output Violet (or Blue) wire connects to Dimming+; Grey (or White) wire connects to Dimming-. 7