RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

Similar documents
RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

LMP series

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

D e s c r i p t i o n

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

SPIN-ON FILTER - LOW PRESSURE LINE

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

FILTERS. TANK CARE - Return filters TECHNICAL DATA DOUBLE PORT MODEL ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

D e s c r i p t i o n

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

FPK 02 AP280. Pressure Line High Pressure Filters In-Line up to 420 bar. Mix&Match to Get What You Need

In line high pressure filters. HF 735 series

CLOGGING INDICATORS SUMMING-UP DESCRIPTION

In line high pressure filters. HF 725 series

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

FBK-FRCA. Return Line Filters Low Pressure Filters In-Line up to 10 bar. Mix&Match to Get What You Need

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

MPF filters within this range are suitable for flow rates up to 750 l/min.

Working pressure. 350 bar. Style B Series FHD 051. Series FHD 325/332 D.I. D.I. D.I. A A

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

THE IMPORTANCE OF AN EFFICIENT FILTRATION

FMM bar. Working pressure. Style T. Style D. Style S. Style B D.I. D.I. D.I. D.I.

Return fi lters. FRI series. Maximum pressure up to 20 bar - Flow rate up to 1500 l/min. Return fi lters

Change-Over Inline Filter RFLD Weld Version

Return Line Filter RFM with 4-Hole Mounting

HIGH PRESSURE FILTERS

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Flow rates to 500 l/min

GEAR PUMPS DIMENSIONAL DETAILS

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Series RFLD Duplex In-Line Filter

HEC2003/2004 Series Servo Valve System

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

In-Line Filters. Section Index. High FPK

In line high pressure filters. HF HF 761 series

HIGH PRESSURE FILTERS

FILTERS. Accessories. CFA - Filling plugs. CBA-CBB - Air breathers. CSF - Filling plugs with threaded air filter. CLA - Visual level indicators

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Pressure reducing valve, direct operated

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

HIGH PRESSURE FILTERS

Stainless Steel Pressure Filters

SERIES. Maximum pressure 110 bar

Low Pressure Filters

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Pressure Filters DF...M A / DF...Q E DF...MHA / DF...MHE Flow rates up to 500 l/min Pressure range up to 315 bar Material: SG Iron/ADI, Steel

Series RFL In-Line Filter

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

HIGH PRESSURE FILTERS

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

The range of products is completed by a number of accessories, including:

Return Line Filters. Section Index

MATERIALS FILTER PRESSURE VALUES

Change-Over Inline Filter AFLD to API 614

MultiRheo Filter MRF 1/2/3/4/5/6/7

Low Pressure Filters

Fluid Cooling Industrial COLW Series

Pressure Filter DF...K P, DF...M P, Flange Mounted

Return Line Filter RF

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

SELF-CLEANING FILTER

MultiRheo Filter MRF 1/2/3/4/5/6/7

FHA 051 Working pressure 6000 psi

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

AIR FILTERS AND FILLER BREATHERS FA3 / FB1 / FB2 / FT series ACCESSORIES HYDRAULIC SYMBOL

Duplex Pressure Filters

SINGLE ACTING METRIC RANGE

Transcription:

COMPONENTS RC MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass APPLICATION EXAMPLE PRESSURE (ISO 10771-1:2002) Max working: 700 kpa (7 bar) Test: 1 MPa (10 bar) Bursting: 2,1 MPa (21 bar) Collapse, differential for the filter element (ISO 2941): 300 kpa (3 bar) BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From - to +110 C COMPATIBILITY (ISO 2943:1999) Full with fluids: HH-HL-HM-HV-HTG (according to ISO 6743/4) For fluids different than the above mentioned, please contact our Sales Department.

FILTER HOUSING kg FRC11 FRC12 FRC21 FRC22 0,3+1,0 0,3+1,3 0,8+1,3 0,8+1,4 3/4 3/4 D1 7 7 9 9 D3 196 241 2 297 H1 36 36 H2 H3 99 99 141 141 40 45 40 45 65 70 65 70 E1 E2 72 72 E3 E4 E5 90 90 124 124 E6 95 95 130 130 D2 15 15 30 30 R INSTALLATION DRAWING RC 45 45 Tank mounting pattern Ø E1 Ø E2 D3

ORDERING AND OPTION CHART RC FILTER ELEMENT A B C kg Area (cm 2 ) Media F+ Media C+ ERC11 96,5 3/4 BSP 146 1,00 2.140 3.305 ERC12 96,5 3/4 BSP 191 1,20 3.630 4.745 C ERC21 129 1 1/4 BSP 1 1,40 4.4 5.0 ERC22 129 1 1/4 BSP 226 1, 5.890 7.360 B A

RC FLUID SPEED (when selecting the fi lter size, we suggest to consider also the max recommended fl uid speed (in return lines normally 1,5 < v < 4 m/s) 3 300 Recommended range FLOW RATE [] 2 200 1 100 1,5 < v < 4 m/s 0 3/4 PORT SIZE PRESSURE DROP CURVES (Δp) The Assembly Pressure Drop ( p) is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than kpa (0,5 bar). FILTER HOUSING PRESSURE DROP (mainly depending on the port size) 0,4 40 FRC 0,3 30 3/4" 0,2 20 0,1 10 0 100 1 200 2 300 3 400 N.B. All the curves have been obtained with mineral oil having a kinematic viscosity 30 cst and specific gravity 0,9 kg/dm 3 ; for fluids with different features, please consider the factors described in the first part of this catalogue. All the curves are obtained from test done at the UFI HYDRAULIC DIVISION Laboratory, according to the specification ISO 3968:2005. In case of discrepancy, please check the contamination level, viscosity and features of the fluid in use.

PRESSURE DROP CURVES (Δp) The Assembly Pressure Drop ( p) is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than kpa (0,5 bar). RC CLEAN FILTER ELEMENT PRESSURE DROP WITH F+ AND C+ MEDIA (depending both on the internal diameter of the element and on the fi lter media) ERC 11 ERC 12 0,75 0,5 0, 75 FB FC FD 0 75 100 1 1 0,75 0,5 0, 75 FB FC FD 0 75 100 1 1 ERC 21 0,75 75 FB FC 0,5 0, FD 0 100 1 200 2 300 ERC 22 0,75 75 FB FC 0,5 0, FD 0 100 1 200 2 300 BYPASS VALVE PRESSURE DROP When selecting the fi lter size, these curves must be taken into account if it is foreseen that any fl ow peak is to be absorbed by the bypass valve, it also must be of proper confi guration to avoid pressure peaks. The valve pressure drop is directly proportional to fl uid specifi c gravity. 4 400 FRC 11-12 4 400 FRC 21-22 3 300 3 300 2 200 2 200 1 100 1 100 0 75 100 1 1 0 100 200 300 400 0 600 N.B. All the curves have been obtained with mineral oil having a kinematic viscosity 30 cst and specific gravity 0,9 kg/dm 3 ; for fluids with different features, please consider the factors described in the first part of this catalogue. All the curves are obtained from test done at the UFI HYDRAULIC DIVISION Laboratory, according to the specification ISO 3968:2005. In case of discrepancy, please check the contamination level, viscosity and features of the fluid in use.

RC CLOGGING INDICATOR A visual or electrical indicator is available as an option and allows monitoring of the element condition. The port for the indicator is a standard feature. QUICK MAINTENANCE The spin-on type fi lter element ensures a quick and easy replacement. EASY REPLACEMENT A anti-drain membrane keeps the oil inside the cartridge and avoid oil losses during the replacement. CLOGGING INDICATOR For further technical informations and other options see page 4. SERIES 30 SPARE SEAL KIT NBR FRC11 521.00.2 FRC12 521.00.2 FRC21 521.0036.2 FRC22 521.0036.2 SERIES P1 B R C FILTER HOUSING B B N X X FILTER ELEMENT ERC N CLOGGING INDICATOR Is this datasheet the latest release? Please check on our website. SPARE PARTS ELEMENTS (For fi lling up see table Ordering and option chart ) Technical data subject to variations without prior notice. RC - EN - 03/2011