Transfer switch GTEC open or delayed transition

Similar documents
Transfer switch OTEC open or delayed transition

GTEC Transfer switch open transition

GTEC Transfer switch Open transition

Transfer switch OTEC and OTECSE open transition

OTEC Transfer switch open transition

Transfer switch OTPC open, closed, or delayed transition

OTPC-SE Service entrance transfer switch open transition

Diesel generator set C17D5T series

Transfer switch OHPC open or delayed transition

CHPC Transfer switch closed transition

BTPC Bypass isolation transfer switch open or closed transition

OTPC Transfer switch open and closed transition

OHPC/CHPC Transfer Switches

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel Generator Set S3.8 Series Engine

Digital generator set control PowerCommand 3100

Transfer switch OT III open or delayed transition, non-automatic

Ground fault indication relay - H550, H666, H667, H668

PowerCommand iwatch Wireless

Remote Monitoring System

Automatic Transfer Switches. Global

PowerCommand 2.2 control system

Paralleling Equipment

Complete Power Systems. Accountability for Every Aspect of Onsite Power Delivery

PowerCommand Paralleling Systems. Robust Paralleling System Solutions For Reliable Performance

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

Power Connect TM Series RX60

Cummins delivers reliable power in one easy-to-use system

PowerCommand 500/550 Remote Monitoring System

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

PowerCommand 2.2 control system

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Diesel generator set QSL9 series engine

PowerCommand. Digital Generator Set Control

Spark-ignited generator set

QSK60 Series Gas Powered Generator Sets

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Lean-Burn Gas Fueled Generator Sets

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

GENSET CONTROL MODULE A121A / A241A

Diesel generator set 4BT3.3 series engine

Gas Project Application Capabilities

PowerCommand 1.2 control system

Bypass/Isolation Switches RTS-03 SERIES

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

Rental Power QSL9 series engine

SECTION GENERATOR ASSEMBLIES PART I - GENERAL

Quick Start Guide TS 910

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

Diesel generator set QSX15 series engine

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Quick Start Guide TS 910 & TS 920

SECTION MOTOR CONTROL

PowerCommand 1.1 control system

PowerCommand 2100 digital generator set control

PowerCommand Digital generator set control

Florham Park, NJ USA Call (ASCO) for sales or service

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

.3 Section Waste Management and Disposal.

Bypass Isolation Transfer Switches Amperes

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

Diesel generator set QSK60 series engine

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

Zenith ZTX. GE Energy Digital Energy. Automatic Transfer Switch

Electropneumatic Timing Relays Series 7000 Industrial

Diesel generator set QSX15 series engine

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

SD Series Non-Fused Load Switches

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Rental Power 1500 kw. Specification sheet. Description. Features. Options

Horizontal Circuit Switchers

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Bolted contact switches. Pringle switches

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

Diesel generator set QSL9-G7 series engine

COOPER POWER CA280012EN

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

Residential and Light Commercial Features Overview

Diesel generator set QSL9 series engine

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Rental Power KTA50 G3 series engine

Rental Power QSB7 series engine

Powering telecoms, keeping people connected. Power generation engineered for telecoms. Our energy working for you. TM

SECTION MOTOR CONTROLLERS

Operator s Manual Series ACTS Automatic Closed Transition Transfer Switches 150 through 4000 amps A. Rating Label.

Diesel generator set QSK23 series engine

DKG-114 MANUAL AND REMOTE START UNIT

GENERAC GUARDIAN SERIES STANDBY GENERATORS

Typical Specification

Spark-ignited generator set

Diesel generator set QSK78 series engine

TS880 AUTOMATIC TRANSFER SWITCHES

Transcription:

Transfer switch GTEC open or delayed transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between a utility and a generator set or between two different utility feeds. The PowerCommand micro-processor control monitors utility and emergency standby generator power. When utility power fails or is unsatisfactory, the control starts the generator and transfers the load from the utility to the generator. Once stable utility power returns, the switch automatically transfers the load back to the utility. High pressure silver alloy contacts withstand thousands of switching cycles without burning, pitting, or welding. They require no routine contact maintenance and provide 100% continuous current ratings. The fully integrated controller is designed for practical functionality, inclusive of LED indicators and digital All switches meet IEC 60947-6-1 AC31B requirements IEC All switches bear the CE mark. This transfer switch is designed and manufactured in facilities certified to ISO9001. Features Microprocessor control - A fully featured microprocessor control is standard. All features, settings, and adjustments are designed for easy operator use via the front display panel. Advanced transfer switch mechanism True transfer switch mechanism with break before make action. Manual operation - Manual operation handle, standard, allows the manual operation of the switch after proper disconnection of power sources. Positive interlocking - Mechanical interlocking prevents source-to-source connection through the power contacts. Main contacts - Heavy-duty silver alloy contacts with multi-leaf arc chutes are rated for 100% load interruption. Easy service/access - Door-mounted controls, ample access space, and compatible terminal markings allow for easy access. User-friendly controller is easily configurable in the field. Product lines, accessories and services - Cummins Power Generation offers a wide range of accessories and services to suit your requirements. Warranty and service - Backed by a comprehensive warranty and worldwide distributor network.

PowerCommand microprocessor control Simple, easy-to-use control provides transfer switch information and operator controls LED lamps for source availability and source connected indication, exercise mode, and test mode. LED status lamps also provided for control set-up and configuration. Control pushbuttons to initiate test, override time delays, and set exercise time. Field-configurable for in-phase or delayed (programmed) transition. Integral exerciser clock Control is prototype-tested to withstand voltage surges per EN 60947-6-1. Gold-flashed generator start contacts Control functions Voltage sensing: All phases on the normal source, and single phase on generator source. Normal Source Pickup: adjustable 90-95%, Dropout: adjustable 70-90% of nominal voltage; Generator Source Pickup: 90%, dropout: 75% of nominal voltage. Frequency sensing: Generator Source Pickup: 90% of nominal frequency; Dropout: 85% of nominal frequency. Operating modes: Open transition with programmed transition (adjustable 0-10 seconds); Open transition with inphase monitor and delayed transition backup; Exercise mode; and Test mode. In-phase: Configurable for initiation of transfer functions when sources are in phase. Includes the ability to enable a delayed transition backup to the function so that if sources are not in-phase within 120 seconds the system will retransfer with delayed transition function. Exerciser clock: Switch is furnished with an integral engine exerciser configurable for operation on a 7, 14, 21, or 28-day cycle with a fixed exercise period duration of 20 minutes. A 12-hr exerciser time offset allows for the convenient setting of exercise time without the need to activate the timer at the exact time that you need to schedule the generator exercise for. Software selectable capability allows for the exercising of the generator with or without load. Time-delay functions Engine start: Prevents nuisance genset starts due to momentary power system variation or loss. Adjustable: 0-10 seconds; default: 3 seconds. Transfer normal to emergency: Allows genset to stabilize before application of load. Prevents power interruption if normal source variation or loss is momentary. Allows staggered transfer of loads in multiple transfer switch systems. Adjustable 0-300 seconds, default 5 seconds. Retransfer emergency to normal: Allows the utility to stabilize before retransfer of load. Prevents needless power interruption if return of normal source is momentary. Allows staggered transfer of loads in multiple transfer switch systems. Adjustable 0-30 minutes, default 10 minutes. Genset stop: Maintains availability of the genset for immediate reconnection in the event that the normal source fails shortly after transfer. Allows gradual genset cool down by running unloaded. Adjustable 0-30 minutes, default 10 minutes. Delayed transition: Controls the speed of operation of the transfer switch power contacts to allow load generated voltages from inductive devices to decay prior to connecting a live source. Adjustable 0-10 seconds, default 0 seconds. Elevator signal: Provides a relay output contact for the elevator signal relay (load disconnect). The signal can also be configured to provide a post transfer delay of the same duration. Adjustable: 0-300 seconds (requires optional elevator signal relay for use). Options Elevator signal relay: Provides a relay output contact for the signal relay function Programmable exerciser clock: Provides a fully-programmable 7-day clock to provide greater flexibility in scheduling exercise periods than standard integral exerciser. Peaking function feature allows for generator operation during periods of high utility rates. Manual restore: Provides a key switch on the front door to allow the operator to control when the switch transfers to the normal source.

Transfer switch mechanism A powerful and economical solenoid powers GTEC Transfer Switches. Independent break-before-make action is common for 2-pole, 3-pole and 4-pole switches. On 4-pole switches, this action prevents the objectionable ground currents and nuisance ground fault tripping that can result from overlapping neutral designs. Mechanical interlock prevents simultaneous closing of normal and emergency contacts. Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of normal and emergency sources through the control wiring. Long-life, high pressure, silver alloy contacts resist burning and pitting. Contacts are mechanically held in both normal and emergency positions for reliable, quiet operation. Specifications Voltage rating Amperage rating Arc interruption Neutral bar Auxiliary contacts Transfer switches up to 480 VAC, 50 Hz or 60 hz. Operating temperature -30 C (-22 F) to 60 C (140 F) Storage temperature -25 C (-13 F) to 55 C (131 F) Humidity Altitude Total transfer time (sourceto-source) Manual operation handles Transfer switches rated for 40 through 1250 continuous amperes. Multiple leaf arc chutes cool and quench the arcs. Barriers prevent interphase flashover. A full current-rated neutral bar is standard on enclosed 3-pole transfer switches. Two contacts rated at 5A continuous at 100 VAC or 2.5A continuous at 200 VAC (one for each source) are provided for customer use. Wired to terminal block for easy access. Up to 90% @ 20 C Up to 2,000 m (6,561 ft) without derating Will not exceed 100 msecs with normal voltage applied to the actuator and without delayed (programmed) transition enabled. Transfer switches are equipped with a removable operating handle which allows operation during servicing in order to facilitate troubleshooting with sources of power disconnected

Short circuit ratings The transfer switches listed below must be protected by fuses. The following WCR ratings are available when protecting the transfer switch with a fuse. Short circuit ratings are stated in symmetrical RMS amperes. Fuse protection Transfer switch ampere WCR @ volts max. with current limiting Max fuse, size and type 40, 63 26,000 @ 480 RT16NT-00 63A 100, 125 26,000 @ 480 RT16NT-00 125A 160, 200, 225, 250 38,000 @ 480 RT16NT-2 250A 350, 400, 500 50,000 @ 480 RT16NT-3 500A 630, 800 55,000 @ 480 RT16NT-4 800A 1000, 1250 65,000 @ 480 RT16NT-4 1250A Enclosures The transfer switch and control are mounted in a key-locking enclosure. Complete enclosure meet IEC 60947-6-1 standard. Dimensions - IP32 Amp rating Height Width Door closed Door open Weight 3-pole type Outline drawing in mm in mm in mm in mm lb kg 40, 63 31.4 800 23.6 600 8.8 226 31.4 800 101.4 46 0500-6004 100, 125 31.4 800 23.6 600 8.8 226 31.4 800 105.8 48 0500-6004 160, 200, 225, 250 39.3 1000 31.4 800 8.8 226 39.3 1000 125.6 57 0500-6005 350, 400, 500 39.3 1000 31.4 800 8.8 226 39.3 1000 143.3 65 0500-6005 630, 800 53.9 1370 29.2 742 24.8 631 53.0 1348 385.8 175 0500-6006 1000, 1250 53.9 1370 29.2 742 24.8 631 53.0 1348 405.6 184 0500-6006 Dimensions - IP54 Amp rating Height Width Door closed Door open Weight Outline drawing in mm in mm in mm in mm lb kg 40, 63 34.0 864 23.3 598 11.6 296 8.7 223 110.2 50 0500-4559 100, 125 34.0 864 23.3 598 11.6 296 8.7 223 110.2 50 0500-4559 160, 200, 225, 250 41.8 1064 31.6 804 11.6 296 8.7 223 143.3 65 0500-4560 350, 400, 500 41.8 1064 31.6 804 11.6 296 8.7 223 143.3 65 0500-4560 630, 800 53.9 1370 29.5 750 26.6 676 23.7 604 414.4 188 0500-4561 1000, 1250 53.9 1370 29.5 750 26.6 676 23.7 604 414.4 188 0500-4561

Submittal detail Amperage ratings 40 63 100 125 160 200 225 250 350 400 500 630 800 1000 1250 Voltage (line-to-line) ratings R971 110 R972 115 R973 120 R974 127 R975 139 R976 220 R977 230 R978 240 R979 255 R980 277 Pole Configuration A027 Poles - 2 (solid neutral) A028 Poles - 3 (solid neutral) A029 Poles - 4 (switched neutral) Frequency A044 60 Hertz A045 50 Hertz Application A035 Utility to genset System Options A041 Single phase, 2-wire or 3-wire A042 Three phase, 3-wire or 4-wire Enclosure B004 Open construction: no enclosure - includes automatic transfer switch and controls B901 IP32 general purpose indoor B014 IP54 general purpose outdoor Control voltage M033 12V, Genset starting voltage M034 24V, Genset starting voltage Control options J030 External exercise clock M032 Elevator signal relay S006 Manual restore switch Battery chargers K001 2 amps, 12/24 volts Auxiliary relays Relays are factory installed. All relays provide (2) sets of form C (DPDT) contacts rated 5A @ 250 VAC. Relay terminals accept (1) 0.75 mm to (2) 4 mm wires per terminal. L101 24 VDC Coil - installed, not wired (for customer use). L102 24 VDC Coil - emergency position - relay energized when GTEC in source 2 (emergency) position. L103 24 VDC Coil - normal position - relay energized when GTEC in source 1 (normal) position L201 12 VDC coil installed, not wired (for customer use) L202 12 VDC coil - emergency position - relay energized when GTEC in source 2 (emergency) position L203 12 VDC coil - normal position - relay energized when GTEC in source 1 (normal) position Warranty Warranty, 12 months from commissioning to a maximum 18 months after date of sale. Americas 1400 73 rd Avenue N.E. Minneapolis, MN 55432 USA Phone: 1 763 574-5000 Fax: 1 763 574-5298 Europe, CIS, Middle East and Africa Manston Park Columbus Ave. Manston Ramsgate Kent CT 12 5BF United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399