Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Similar documents
Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

VLM20 In-line Vortex Flowmeter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Multivariable Vortex Flow Meter

Armstrong In-Line and Insertion Vortex Flow Meters

Multivariable Vortex Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

Vortex Flow Meter Model DVH

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

F-2500 SERIES VORTEX METER

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Vortex Eggs Delta Flowmeter

Vortex In Line Flow Meter

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

F-2600 SERIES INLINE VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

VORTEX IN-LINE FLOW METERS

Vortex In Line Flow Meter

Vortex Flowmeter Model DVE

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

VersaFlow Vortex 100 Vortex Flow Meter Specifications

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

VIM20 Vortex Insertion Flowmeter

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

SRT1000 Series THERMAL FLOWMETER

VIM20 Vortex Insertion Flowmeter

Transmitting Transducer. Gas/Air Velocity Range:

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

The readings you need, right where you need them. AX Series Vortex Meters

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

OPTISWIRL 4070 Technical Datasheet

Fundamental Training. Flow Con t

VIM20 Vortex Insertion Flowmeter

Series 8000 Vortex Flow Meter

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

The Multivariable Air Flow Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

OPTISWIRL 4070 Technical Datasheet

VersaFlow Vortex 100 Vortex Flow Meter Specifications

flow measurement solutions RIM10 series rotor insertion flowmeters

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

유량계전문제조업체. Electro Magnetic FLOWMETER

F-1500 SERIES INSERTION TURBINE FLOW METER

Detector (for water measurement applications)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

The readings you need, right where you need them. AX Series Vortex Meters

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

4-20mA, pulse with HART or pulse with RS485 are selectable. No moving parts, no abrasion, non-wearing parts inside, fully welded SS304

The Multivariable Air Flow Meter

Electric Top-Guided Single-Seated Control Valves

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

RCM - Direct Reading Flowmeters

CATALOG KVFN. Vortex Flowmeter

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Hot Tap Insertion Vortex

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

SITRANS FX300 4/289. System Overview. Overview

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

Paddle-wheel flow controller with optical principle for On/Off control

CATALOG KTLU. Vortex Flowmeter

RIM20 Rotor Insertion Flowmeter

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Rosemount 8800D Series Vortex Flowmeter

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

STEEMCO Flowmeter for Steam

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

ORIMAS Mass Flowmeter

General Specifications

STEEMCO-MAS Flowmeter for Steam

LCMass Series Mass Flow Sensor

RCM. Direct Reading Flowmeter. for Liquids or Gases

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

CATALOG KVFN. Vortex Flowmeter

General Specifications

Rosemount 1195 Integral Orifice Primary Element

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

INSERTION flow sensor for continuous flow measurement

Metal tube variable area flowmeter for gases, liquids and steam

Hydro-Flow Model 3100

Magnetic Inductive Flowmeter EP / UMF2 (B)

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Flowmeters Selection Guide

Rosemount 8800D Series Vortex Flowmeter

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Temperature Indicating Controller

VERIS FLOW MEASUREMENT GROUP

Product Data Sheet , Rev GA Catalog Content

Low Profile Insertion Vortex

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Vortex Plate. Model VP General Specification. Product Features

VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual

Transcription:

Digital Vortex meter digitalyewflo Digital Vortex meter Series

Unrivaled Performance, Functionality and Ease of Use Series Standard Type / Multi-variable Type High Temperature / Cryogenic Type Reduced Bore Type Simple body construction for easy installation and high level of safety Measurement principle When a shedder bar is placed in a flow, Karman vortices are generated on the downstream side of the bar. The Karman vortices are detected by two piezoelectric elements installed in the upper part of the shedder bar. The vortex frequency is proportional to the flow velocity in a specific range of Reynolds numbers. Therefore, flow velocity or flow rate can be determined by measuring vortex frequency. Piezoelectric elements Shedder bar Features of the Vortex meter Measurement tube Easy installation, with flange or wafer process connections. No zero adjustment is needed. No moving parts make Vortex meters highly durable and reliable. The sensing element and bluff body are combined in a single shedder bar, minimizing the pressure loss. The flowmeter is leak-free with a high degree of safety. Robust construction of the shedder bar makes measurement at high temperatures (max. 450 C) and high pressure possible.

Standard Type Yokogawa s proprietary filter (SSP) for digital signal processing analyzes vortex signals and automatically selects the optimum settings for the best possible measurement. Noise Reduction Noise caused by strong vibration may affect the accuracy of vortex frequency detection. The two piezoelectric elements installed in digitalyewflo are of a polarized structure, so they do not detect vibration in the flow or vertical directions. The noise of vortex (lift)- direction vibration is reduced by adjusting the outputs of the piezoelectric elements. Combining these features with the Spectral Signal ing (SSP) provides optimum and stable measurement. Piezoelectric elements Lift direction Vertical direction direction Fieldbus communication compatible digitalyewflo s SSP function provides enhanced vibration immunity and advanced diagnostics. In the past some situations required manual adjustment to compensate for vibration noise. digitalyewflo is a maintenance-free flowmeter. It has a circuit for analyzing the detected frequency and allows only vortex frequency to pass through the segmented band-pass-filter, thereby accurately identifying and eliminating noise. The Spectral Signal ing (SSP) function of digitalyewflo only outputs the appropriate vortex frequencies, even under fluctuating flow rate conditions. Input signal Frequency analysis (SSP function) Judged to be noise Judged to be vortex signal Judged to be noise Removed Output Removed Lower Cost of Ownership S Enhanced vibration immunity! No adjustment costs! S Maintenance free! The self-diagnostic function reduces regular maintenance costs. S User-friendly! Parameters are easily set by categorizing frequently used parameters into one group, reducing total maintenance costs!

High Temperature Version / Cryogenic Version For high temperature or cryogenic flow measurement. Measurable temperature range: Maximum 450 C, Minimum -196 C Easy installation and high level of safety with minimum fugitive emission points. Same face-to-face dimension as the Standard Type Simple construction for easy insulation Available with Reduced Bore Type * Remote Type is used for high process temperature / cryogenic applications. Must be combined with Model DYA remote converter. Specification Model & Suffix Code Fluid to be measured Nominal size Accuracy Output signal temperature range pressure limit Ambient temperature Ambient humidity Mounting Electrical connection Explosion protected type Material Standard Reduced Bore Multi-Variable Model DY Vortex meter (Integral type, Remote type) Model DYA Vortex Converter Suffix Code: /R1, /R2 Suffix Code: /MV Liquid, Gas, Steam (Avoid multiphase flow and sticky fluids.) 15 mm - 300 mm (400 mm: special) R1: 25 mm - 200 mm, R2: 40 mm - 200 mm 25 mm - 200 mm Liquid: 1.0% of reading (20000 Re Dx10 3 ) Liquid: 1.0% of reading (20000 Re Dx10 3 ) Liquid: 1.0% of reading (20000 Re) Liquid: 0.75% of reading (Dx10 3 Re) Liquid: 0.75% of reading (Dx10 3 Re) Gas, Steam: 1.0% of reading ( velocity less than 35 m/s) Gas, Steam: 1.5% of reading ( velocity 35 m/s - 80 m/s) Dual Output (both analog and transistor contact output can be obtained simultaneously.) Analog Output: 4-20 ma DC, 2-wire system Transistor Contact Output: Open collector, 3-wire system Pulse, Alarm, Status output are selectable. Contact rating: 30 V DC, 120 ma DC Low level: 0 to 2V DC -29 C - 260 C (general) -196 C - 100 C (option: Cryogenic version) -29 C - 450 C (option: High Temperature version) -0.1MPa(-1kg/cm 2 ) to flange rating. -29 C - 80 C (Integral type with Indicator) -29 C - 85 C (Remote type detector) -30 C - 80 C (Remote type converter with Indicator) 5 to 100%RH (Non condensing) Integral type and Remote type detector: Flange mounting or wafer mounting Remote type converter: 2 inch pipe mounting JIS10/20/40, ANSI150/300/600/900, JPI150/300/600, DIN PN10/16/25/40,Available,Not available,available Flange mounting only JIS10/20K, ANSI 150/300, JPI150/300 JIS G1/2 Female, ANSI 1/2NPT Female, ISO M20 1.5 Female TIIS F.P., FM E.P./I.S., CENELEC ATEX (KEMA) E.P./I.S./type n, CSA E.P./I.S., SAA E.P./I.S., SAA E.P./I.S. Body: SCS14A casting stainless steel (equivalent to SUS316, CF8M) Shedder bar: Duplex stainless steal (option: anti-corrosive version) Gasket: SUS316 stainless steel with polytetrafluoroethylene (Teflon) coating Converter housing and case cover: Aluminum alloy Indication: Upper: FLOWRATE(%), FLOWRATE, *TEMPERATURE(%) Lower: BLANK, TOTAL, *TEMPERATURE *Options available for Multi-variable Type only,available,not available,not available Integral type and Remote type detector: Flange mounting or wafer mounting Remote type converter: 2 inch pipe mounting JIS10/20/40, ANSI150/300/600/900, JPI150/300/600, DIN PN10/16/25/40

Reduced Bore Type Minimum measurable flow up to five times lower than conventional vortex flowmeter. Integrated construction with reducers built into the flowmeter body. Integrated construction allows for size reduction up to 2 sizes smaller Enhanced safety realized by integrated construction No leak points! Same face-to-face dimension as the Standard Type makes replacement easier. * The face-to-face dimension is the same as that of YEWFLO*E (Style E). Same face-to-face dimension Standard Type (DY***) Reduced Bore Type (DY***/R1, /R2) Measurable Rate Range (saturated steam: normal pressure 500 kpa) Reduced bore type (pipe/detector) DY/R2 (50/25mm) 22kg/h 475kg/h Pressure loss higher than that of the standard type by 28% Measurement of low flow rates Reduced bore type (pipe/detector) DY/R1 (50/40mm) 44kg/h 1132kg/h Pressure loss higher than that of the standard type by 15% Measurement of low flow rates and wide range measurement DY standard type (50mm) 74kg/h 1876kg/h Very wide range measurement 0 500 1000 1500 rate (kg/h) Lower Cost of Ownership S No need for reducers/expanders or short pipes to achieve the required straight pipe length! Improves safety and reduces installation costs! S Increases the space for installation of additional instrumentation. S Improved stability in measuring low flow ranges! A single unit can perform such measurements, thereby reducing instrumentation costs. New instrumentation using Reduced Bore Type Traditional instrumentation Reducer Short pipe Short pipe Expander Upstream side 10D Downstream side 5D Upstream side 10D Upstream side 5D Downstream side 5D

Multi-variable Type The world s first two-wire Multi-variable Type (with built-in temperature sensor) can directly output the mass flow rate of saturated steam. Shedder bar with built-in temperature sensor has a temperature monitoring function and a mass flow rate calculation function. Shedder bar with built-in temperature sensor: The shedder bar, which is strong enough to be used as a thermo-well, incorporates a RTD sensor (equivalent to Pt1000, Class A) for temperature measurement. SSP function facilitates highly accurate measurement of flow rate over a wide range, even under radically fluctuating temperatures. A combination of the reduced bore and multi-variable types is ideal for saturated steam instrumentation when the flow rate fluctuates largely. Pressure (P) 50 Saturated steam curve Temperature Sensor Built-in temperature sensor housed inside the shedder bar. 25 Density Based on signals from the temperature sensor, which is protected by the shedder bar serving as a protector tube, the mass flow rate of saturated steam is calculated. 0 0 100 200 300 Temperature (T) Density is calculated from temperature measurement using the saturated steam curve. Mass flow rate Temperature Temperature monitoring function Readings of flow rate and temperature measurements are displayed simultaneously. Volumetric flow rate or mass flow rate (Pulse output) Totalized value Temperature value (analog) temperature value control Mass flow rate calculation function The saturated steam curve based on temperature measurement is used to directly output mass flow! Lower Cost of Ownership A single digitalyewflo unit can perform highly accurate measurement of saturated steam. The ultimate solution for energy-efficient steam control Robust body and shedder bar construction for safer measurement and control The SSP function facilitates highly accurate measurement even when the boiler is vibrating. S A high level of safety is assured without the expense or installation of a temperature sensor, and an insertion hole is not required. S Neither an external output temperature display unit nor a square root extractor is needed. New saturated steam instrumentation of Multi-variable Type Upstream side 10D Downstream side 5D Traditional saturated steam instrumentation of T/P COMP. T/P compensator Pressure transmitter 20D or greater Orifice DP transmitter 3-valve Impulse pipe Valve 5D or greater Temp. amp. Resistance thermometer bulb

Printed in Japan, 702(KP) [Ed : 01/b] Subject to change without notice. All Rights Reserved, Copyright c 2007, Yokogawa Electric Corporation.