Bridging The Gap Effectively... SWITCHGEAR Panels Components Accessories Relay & Meters

Similar documents
DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

PROJECT CONSULTANT AND MANUFACTURER FOR ELECTRICAL INSTALLATION FOR INDUSTRIAL AND COMMERCIAL APPLICATIONS

S H A D E S ELECTRICAL DB MANUFATURING

Metal Clad VCBs ~ Mk1

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Air-insulated switchgear UniGear type ZS1

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

MEDIUM VOLTAGE SWITCHGEAR

Welcome to Corporate Presentation

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

TECHNICAL SPECIFICATIONS OF PCC PANEL

MESG 12 / 17.5 / 24 / 36 KV

HOTLINE ELECTRICAL TRADING

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

PIX-H Metal-clad switchgear up to 17.5kV

COMPACT SUBSTATION GUIDE

Extensible Unit - VCE2a

Unitole UP kv Primary substations Motor control centres

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Unitole UP kv Primary substations Motor control centres

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Metal Clad Switchgears

Gas Insulated Metal-clad Switchgear, HMGS!

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Adak Behin Niroo. co.com

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

33KV INDOOR SWITCHGEAR

Contents. We build a better future! MCC HCB

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

TRANSMISSION SYSTEMS

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Key features. DESIGNS: - Conservator type - Hermetically sealed

Power IT Air Insulated Cubicle Uniswitch

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

LT - HT PANELS. Engineered for Performance, Tested for Reliability

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Metal Clad Air Insulated Switchgear

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

PC3.0/MNS R 690 V A Main low voltage distribution switchgear

Unified requirements for systems with voltages above 1 kv up to 15 kv

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

NS Feeder pillar up to 3200A

the safe, reliable, and efficient choice for MV switchgear

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Medium Voltage Metal-Enclosed Switches

Service Entrance Methods

PowerCube type PB series A complete solution for OEMs

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Ed rev.0 CATALOGUE SWITCHGEAR 2015

Custom Medium and LV Switchgear 5-38kV Switchgear Power Systems

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

An electrical panel capable of evolving

Joslyn Clark Controls, Inc. Simple, Safe, Retrofit Programs to Significantly Extend Life of Existing Circuit Breakers

with Vacuum Circuit Breaker HAF

SafeGear TM Motor Control Center Arc resistant metal-clad construction

UniGear. Technical Guide

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DG SYNCHRONIZING &AMF PANEL

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Moulded Case Circuit Breakers

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Modular Standardized Electrical and Control Solutions for Fast Track Projects

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Transcription:

C NSULTANCY C MPANY Bridging The Gap Effectively... SWITCHGEAR Panels Components Accessories Relay & Meters

Switchgear - Panels Product Range: Medium Voltage Air Insulated Switchgear 415V Switchgear / Power Control Center Motor Control Center Auto Transfer Switch Contactor Based Breaker Based Solid State or Controller Based Main Switch Board (MSB) Sub Main Switch Boards (SMSB) Distribution Boards (DB) Feeder Pillars (FP) Automatic Power Factor Correction Panels (APFC) Control & Relay Panels (CRP) Alarm Annunciation & Monitoring Panels (AAMP) Weather Proof Enclosure for Switch Fuses, Isolators, MCCB Telephone Terminal Boxes Local Control Station Marshalling Box Junction Box Power Junction Box Street Lighting Junction Box HT Power cable Junction Box (Details on request) Switch Socket Outlet Multiple Outlet Combination Unit DG Synchronization Panel BusDucts Mimic Panels Soft Starter Panels AMF Panels VFD Panels 2 www.hcco.in

Our Offerings Japan SWITCHGEAR PRODUCTS Germany SEMICONDUCTORS FUSES U.S.A MIDGET & TIME DELAY FUSES Japan SWITCHGEAR PRODUCTS U.K. PHOTO ELECTRIC SENSORS & PROXIMITY SWITCHES RRISHABH POWER, SEMI CONDUCTORS & SEMICONDUCTORS FUSES 3 www.hcco.in

Medium Voltage Air Insulated Switchgear HCCO switchgear is fully in accordance with relevant IEC standard (IEC 60298, IEC 60694, IEC 60529, IEC 62271 etc.) and other relevant standards. The offered Air Insulated Switchgear are type tested, indoor type metal clad switchgear, assembled under OEM Quality Control. They are offered with proven high performance VCB (Vacuum Circuit Breaker). Our Switchgear are in-line with the Far East, South East Asia and Africa Speci cation. HCCO is ready to cater you with variety of brands of 11kV Switchgear comes from different manufacturer. We are offering ABB, Jyoti, C&S Efacec, L&T, LSIS, Schneider, Siemens & other brands as what you need. Rated Voltage (kv) 7.2kV 12kV 24kV 36kV Rated Power Frequency 20kV 28kV 50kV 70kV Rated Impulse Withstand Voltage 60kV 75kV 125kV 170kV Rated Current (A) 630-2500/3150A 630-2500/3150A 630-2500A 630-2500A Type of Application Indoor Indoor/Outdoor Indoor Indoor/Outdoor Short Circuit Rating (ka) 25kA, 26.3kA, 315kA, 25kA, 26.3kA, 315kA, 40kA 25kA,31.5kA 25kA Short Time Duration (S) 3Sec 3Sec 3Sec 3Sec Construction Withdrawable/Cassette Withdrawable/Cassette Withdrawable Withdrawable Internal Arc Tested 0.5 Sec (1 Sec* for selected brand) 0.5 Sec (1 Sec* for selected brand) 1 Sec 0.5 Sec Short Circuit Rating (ka) 25kA 25kA 25kA 25kA (*17.5kV can be offered) 4 www.hcco.in

Salient Features: Basic Interlocks: 1) Circuit Breaker cannot racked in or racked out unless VCB is in Open Condition. 2) Circuit Breaker cannot be inserted into service position unless Auxiliary Circuit Plugs are connected. 3) Circuit Breaker can only be closed at Service, Test or removed position. Intermediate position VCBs will not be able to close. 4) Earthing switch cannot be closed unless Circuit Breaker is at removed position. 5) Circuit Breaker cannot be inserted into service position unless earth switch are fully open. Safety Shutters Padlocking (Optional) Compartmental Design Why HCCO?? Hamzavi will bring you the optimum solution for your need from the variety of brands in view of your technical requirement with the consideration of spacing and budget. 5 www.hcco.in

415V Switchgear (LV Switchgear) / Power Control Center HCCO offered LV Switchgear are Floor Mounted type and with cellular construction. LV Switchgear also termed as LT Panel or Main Low Tension Board are generally fed from Transformer or Generator for the source of Incoming Power through ACB. Which further connects to Main Horizontal Busbar in order to feed to Outgoing circuits through Outgoing ACBs or MCCBs. HCCO can offer you wide range of products with different brands as per your need. We mainly deal with ABB, L&T, LSIS, C&S, Schneider and Siemens. We also have the solutions from high quality market from Chinese companies such as CHINT & People Electric Group. HCCO can provide varieties of switchboards such as, Modular of Fixed Construction, Non Drawout or Drawout type, with safety interlocks and optional cable termination front/rear access. Also, it can come in variety of form of construction like Form 3 or Form 4. Generally PCC acts as an Incomer to MCC, PDB (Power Distribution Boards) or MLDB (Main Lighting Distribution Boards). Technical Speci cations: Application Construction Type Form of Construction Degree of Protection Rated Operating Voltage Rated Current Rated Insulation Voltage Installation Short Circuit Withstand Current Cable Entry Ambient Temperature Applicable Standards Power Distribution Modular / Fixed Drawout / Non-Drawout Up to Form 4 Up to IP 54/IP55 440Volts 6300A 690Volts Indoor / Outdoor Optional Up to 100kA for 1 Sec Bottom (Default) / Top (Upon Request) 50 Centigrade / 55 Centigrade (On Request) IEC 439 6 www.hcco.in

Motor Control Center (MCC) MCC designed to provide suf cient protection for Motor or Pumps from Overload, Short circuits. MCCs are directly connected to the equipment running in plant. MCCs are fed from PCCs via MCCBs and connected to various Motor or Pumps with control circuit which generally consist OLR (Over Load Relay), Main Contactor (for Power Input to Motor) and Auxiliary Contactor (For Control, Interlock, status and Indication use) and relays or other protective means. HCCO offered MCC are in line with the client requirement with wide range of varieties. MCC panels comes with Bolted Modular construction with spacious arrangement for cable termination which ensures comfortable operation and easy maintenance. Technical Speci cations: Application Construction Form of Construction Degree of Protection Rated Operating Voltage Rated Current Rated Insulation Voltage Installation Short Circuit Withstand Current Cable Entry Ambient Temperature Applicable Standards Motor/Pump control Front Access Only, Single Front with rear access, double front Up to Form 4 Up to IP 54/IP55 440Volts/415Volts 3000A 690Volts Indoor Up to 50kA for 1 Sec Bottom (Default) / Top (Upon Request) 50 Centigrade / 55 Centigrade (On Request) IEC 439 7 www.hcco.in

Auto Transfer Switch (ATS) Auto Transfer designed to transfer the power from normal power source to emergency power source and vice versa. ATS comprises of Power Switching Assembly (PSA), Control Unit Assembly (CUA) and the enclosure. HCCO is offering variety of ATS Panel depending on the switching device. Contactor Based ATS Circuit Breaker Based ATS Solid State ATS (or Controller based ATS) Contactor Based ATS: Contactor based ATS are used frequent. As it is cost effective solution. The contactors used for ATS are designed for frequent switching of the load current and normally used as part of Motor starters. Limitation with Contactor based ATS is it works for only switching of power from one source to another and in no way it can protect the circuit from the fault. Contactor Based ATS Breaker Based ATS ATS Controller Circuit Breaker Based ATS: Breaker based ATS are used as and when there is need of protection during power transfer from one source to another. MCCBs are used to protect the circuit during the transfer. Advantage over Contactor Type ATS: As the circuit breakers are interrupting fault current, even without trip unit, the self-protecting feature is a main advantage of CB type ATS over Contactor type ATS. CB based ATS generally integrate all the functions of Contactor based ATS; as well as it can also include Over Load and Short Circuit protection of Normal and Alternate sources, if it is supplied with Trip Unit. 8 www.hcco.in

In some cases ATS will try to transfer during fault, during this faulty transition, circuit breaker type ATS will successfully disconnect the faulted load and complete the ransfer. Unlike Contactor based ATS as the contactors are not rated for interrupting the fault current. Solid State ATS (or ATS Controller): Solid state ATS are designed for most quick transfer for the power. It transfers the power with less than ¼ of a cycle. Its fast enough not to affect any operation of the computer equipment and most useful in emergency services like in Hospitals. Switching device or Power switching assemble for (PSA) for ATS Controllers are Silicon Controlled Recti ers and control unit (CSU) for this ATS is Microprocessor based control unit. As Emergency Generator Set cannot be switched on in such short response it is not possible to use solid state ATS but it can be used only with the system having two constantly available power source and where the nature of the load is such that there is no feasibility of power outage. However, although it is one of the most reliable method but due to its high cost it is not used generally unless otherwise speci ed. 9 www.hcco.in

Main Switch Boards (MSB) / Sub Main DistributionBoards (DB) Main Switch Boards/Sub Main Switch Boards (MSB/SMSB) are totally enclosed, usually oor mounted and non-cellular construction. Incoming supply is fed from LV Switchgear/PCC through MCCB and fed to various outgoing circuits and other downstream equipment through MCCB as feeders. Generally for Oil & Gas industries, feeder MCCBs are generally provided with Earth Fault relays (ELR), if required and same can be wired to Trip the CB or for Audio/Visual Alarm. Sub Main Distribution Board (DB) Technical Speci cations: Application Construction Type Form of Construction Degree of Protection Rated Operating Voltage Rated Current Rated Insulation Voltage Installation Short Circuit Withstand Current Cable Entry Termination Access Ambient Temperature Applicable Standards Power Distribution at consumer end. Fixed Floor Mounted/Wall Mounted. Up to Form 2 Up to IP 54 440Volts/415Volts 1250A 690Volts Indoor / Outdoor Optional Up to 50kA for 1 Sec Bottom (Default) / Top (Upon Request) Front 50 Centigrade / 55 Centigrade (On Request) IEC 439 10 www.hcco.in

Final Distribution Boards (DB): Final Distribution boards are totally enclosed, usually wall mounted and non-cellular construction. Incoming supply is fed from SMDB/PCC/LT Switchgear through MCCB/Isolator and fed to various outgoing circuits and equipment through CBs/RCBO/ELCB. Final Distribution Board (DB) Technical Speci cations: Application Construction Type Form of Construction Degree of Protection Rated Operating Voltage Rated Current Rated Insulation Voltage Installation Short Circuit Withstand Current Cable Entry Termination Access Ambient Temperature Applicable Standards Power Distribution at consumer end. Fixed Floor Mounted Up to Form 2 Up to IP 54 440Volts/415Volts 150A 690Volts Indoor / Outdoor Optional Up to 50kA for 1 Sec Bottom (Default) / Top (Upon Request) Front 50 Centigrade / 55 Centigrade (On Request) IEC 439 11 www.hcco.in

Automatic Power Factor Correction Panel (APFC) Every Electricity Company is concerned for the maximum ef ciency and minimum Reactive Power in the network. In everyday life each household, commercial premise or industry utilizes large load which are inductive by nature, such as MOTORS, ACs, Large Machines etc. This will effect in rise in reactive power and reduction of active power or useful power use. To avoid this situation various utilities have their pre-de ned limit for such use of reactive power, which is expressed in terms of POWER FACTOR. Power Factor de ned as ratio of Active Power to Apparent Power. Higher the reactive power consumption lesser will be the Active Power and in turn less will be the Power Factor. General Guidelines are to maintain Power Factor as close as to unity this can either be done by switching or removing off the load which is practically not possible or by using the Capacitor Banks. However, to use Capacitor bank with the situation of frequent change of loads, it's dif cult to make manual operation for Capacitor bank continuously. To overcome such dif culties APFC relays in a panel with capacitor banks are used. This panel is termed as APFC Panel. The main advantages for APFC panels are Economical Easy Installation Maintain Power Factor to desired limit and so reduced demand charges. Prevents leading power factor during low load period. Reduced load current, distribution losses and heating of transformers and cables Increase service life of all electrical equipment. Shortest payback period. HCCO brings you international reputed brands with optimum choice of price and cost. We can provide you with brands like Schneider, Circutor, EPCOS/Siemens components. Technical Speci cations: Application Construction Type Form of Construction Degree of Protection Rated Operating Voltage Rated Current Rated Insulation Voltage Installation Short Circuit Withstand Current Cable Entry Range Ambient Temperature Applicable Standards Power Factor Correction With or Without Harmonic Filters Floor Standing Up to Form 2 Up to IP 41 440Volts/415Volts As per request. 690Volts Indoor Up to 50kA for 1 Sec Bottom 10 to 2400kVAR 45 Centigrade IEC 439 APFC Panels 12 www.hcco.in

Control & Relay Panels (CRP) Alarm Annunciation and Monitoring Panel 13 www.hcco.in

Weatherproof Enclosure for Switch Fuse,Isolator and MCCB Telephone Terminal Boxes (Telephone DBs) 14 www.hcco.in

Local Control Station Marshalling Box 15 www.hcco.in

Junction Box Street Light Junction Box 16 www.hcco.in

Switch Socket Outlet Multiple Outlet Combination Unit 17 www.hcco.in

DG Synchronization Panel Bus Duct 18 www.hcco.in

Mimic Panels Soft Starter Panels 19 www.hcco.in

AMF Panels VFD Panels 20 www.hcco.in

C NSULTANCY C MPANY Bridging The Gap Effectively... Ahmedabad 29, Silver Plaza, Maktampura Cross Road, Ahmedabad,Gujarat, India - 380055. Email: sales@hcco.in Corporate Office: 704, Pratiksha Complex, Opp. Shalimar Complex, Mahalaxmi Five Roads, Paldi, Ahmedabad 380007. Ph.: + 91 79 654 12 610 E: info@hcco.in Mumbai 3, Samir Building, Opp. A-29, Road No.6, Parksite, Vikhroli (W), Mumbai, India - 400079. Email: mumbai@hcco.in Indonesia Bandung Pesona Bhayangkara Indah No.16 Cileunyi, Bandung,Indonesia. Contact: +62 22 922 560 68 Email: indonesia@hcco.in Malaysia Coming Soon... www.hcco.in