SNR-FOSC-D-T. Installation Manual SNR-FOSC-D-T. Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

Similar documents
SNR-FOSC-F. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-F. Installation Manual

SNR-FOSC-D. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-D. Installation Manual

HSC-O1. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC)

SNR-FOSC-H. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-H. Installation Manual

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

B1-OPCL Installation Manual

Horizontal Fiber Optic Splice Closure (FOSC) FOSC-GPJ-A024. Installation Manual

FOSCHF Horizontal Fiber Optic Splice Closure

FOSC-400A4 INSTALLATION INSTRUCTION

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

FOSC-100 B/H FOSC-100 B2/H

FOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice 2-2

COYOTE Splice Case. Value conscious and benefit-packed: The COYOTE Splice. 2-2 (440)

3000SC Fiber Optic Splice Closure

OPTICAL FIBER CLOSURE

Closure End Plates and Accessories

Fiber optic splice closure

COYOTE Closure. Origin of the Species. Key Features: PATENTED 1-14

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Heat Shrink closure Non - Pressurized & Pressurized RTSM Dome Closure RLSS RPBS Vault Closure Lead Sleeve Mechanical Closure Pillar Dp Jointing Kit

Power Connection Kit installation instructions

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

Section 3 FIBERLIGN Closure Series

19 1HU Splicing and Front Patching Shelf

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

3M Fiber Dome Closure FDC 10

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

CS Fiber Optic Splice Case. Instruction

Features: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.

COYOTE. Retrofit Closure. Refinement of the Breed. COYOTE Retrofit Closure. The ideal Closure for replacement or expansion 1-29

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

Opti-Guard Splice Enclosure

COYOTE Terminal Dome Closure 6.5" x 22"

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

COYOTE LCC (Low Count Closure)

WRSS Wraparound Repair Sleeve Installation Instructions

OAsys. Outside Plant. Metallic Joint Closure VXOK units. Features and Benefits

Opticom Rack Mount Fiber Enclosures

ET-PWR-END-KIT Installation Instructions (part #JSR00)

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

HANDLING OF ASSEMBLY... 1 RRH END OF ASSEMBLY... 1 BASE STATION END OF ASSEMBLY... 7 POWER CODING REVISION HISTORY... 11

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

Series 3 & 4 Stainless Steel - Accessories

INSTALLATION INSTRUCTIONS

C Power Connection Kit

8400 Series Fiber Distribution System

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

INSTALLATION INSTRUCTIONS

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Read these instructions thoroughly before attempting to install this option.

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

B Polyethylene Tape. B Splicing Covering. Holster

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

LiteDOT Installation Document

INSTALLATION INSTRUCTIONS

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

PIGGING PRODUCTS. Capex supply. PIG LAUNCHER and RECEIVER

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Banks Monster Exhaust System Ram 1500, 3.0L EcoDiesel Factory Single/Side Exit Exhaust

Fiber Splice Panel Rack Mount User Manual

Fiber Connector Shelf (CCS)

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Terminator DP/FAK-5 and FAK-5L

INSTALLATION INSTRUCTIONS

Upgrade v3 to v3.2. SeeMeCNC Guides. Upgrade v3 to v3.2. Rostock Max v3 Uprgade to v3.2. Written By: SeeMeCNC seemecnc.dozuki.

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Multilink s Family of Wall Mount Enclosures

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

INSTALLATION INSTRUCTIONS

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Road / PO Box 186 Humboldt, KS P: F:

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

PEDCAP-R-2, R-3 & R-4S/4L-INT

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

Section 1 COYOTE Closure Series

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

CHIP FUSE; RECTANGULAR TYPE. RoHS COMPLIANCE ITEM Halogen and Antimony Free

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Transcription:

(FOSC) SNR-FOSC-D-T Installation Manual

1. Scope of application This Installation Manual suits for the Fiber Optic Splice Closure (Hereafter abbreviated as FOSC), as the guidance of proper installation. The scope of application is: aerial, underground, wall-mounting, duct-mounting and handholemounting. The ambient temperature ranges from 40 to +65. 2. Basic structure and configuration 2.1 Dimension and capacity Outside dimension (Height x Diameter) Weight (excluding outside box) Number of inlet/out ports Diameter of fiber cable Capacity of FOSC 288mm 178mm 1550 g 1740g 5 pieces in general Φ8mm~Φ20 mm Bunchy: 4-48 (cores) 2.2 Main components No. Name of components Quantity Usage Remarks 1 FOSC cover 1 piece Protecting fiber cable 2 Fiber optic splice tray (FOST) Max. 4 trays (bunchy) splices in whole Fixing heat shrinkable protective sleeve and holding fibers 3 Fiber holding tray 1 pcs Holding fibers with 4 Base 1set Fixing internal and external structure 5 Plastic hoop 1 set Fixing between FOSC cover and base 6 Seal fitting 1 piece Sealing between FOSC cover and base 7 Pressure testing valve 1 set After inject air, it is used for pressure testing and sealing 8 Earthing deriving device testing 1 set Deriving metal parts of fiber cables in FOSC for earthing connection 1 Height x Diameter 208mm x 132mm Suitable for: Bunchy:4,6,8,12(cores) Configuration as per requirement Configuration as per requirement

2.3 Main accessories and special tools No. Name of accessories Quantity Usage Remarks 1 Heat shrinkable protective sleeve Protecting fiber splices 2 Nylon tie Fixing fiber with protective 3 Heat shrinkable fixing sleeve (single) 4 Heat shrinkable fixing sleeve (mass) coat Fixing and sealing single fiber cable Fixing and sealing mass of fiber cable Configuration as per capacity Configuration as per capacity Configuration as per requirement Configuration as per requirement 5 Branching clip Branching fiber cables Configuration as 6 Earthing wire 1 piece Putting through between earthing devices 7 Desiccant 1 bag Put into FOSC before sealing for desiccating air 8 Labeling paper 1 piece Labeling fibers per requirement 9 Special wrench 1 piece Tightening nut of reinforced core 10 Metal hoop 1 set For wall mounting and pole hugging 11 Buffer tube decided by customers Hitched to fibers and fixed with FOST, managing buffer. 12 Aluminum foil paper 1 pc Protect the bottom of Fiber Optic Splice Closure and cable inlet/outlet tubes when heat the heat shrinkable sleeves. Configuration per requirement as 3. Necessary tools for installation 3.1 Supplementary materials (to be provided by operator) Name of materials Scotch tape Ethyl alcohol Gauze Usage Labeling, temporarily fixing Cleaning Cleaning 2

3.2 Special tools (to be provided by operator) Name of tools Fiber cutter Fiber stripper Combo tools Usage Cutting off fiber cable Strip off of fiber cable Assembling FOSC 3.3 Universal tools(to be provided by operator) Name of tools Band tape Pipe cutter Electrical cutter Combination pliers Screwdriver Usage and specification Measuring fiber cable Cutting fiber cable Take off of fiber cable Cutting off reinforced core Crossing/Paralleling screwdriver Scissor Waterproof cover Metal wrench Waterproof, dustproof Tightening nut of reinforced core 3.4 Splicing and testing instruments (to be provided by operator) Name of instruments Fusion Splicing Machine OT DR Provisional splicing tools Fire sprayer Usage and specification Fiber splicing Splicing testing Provisional testing Sealing heat shrinkable fixing sleeve Notice: The above-mentioned tools and testing instruments should be provided by the operators themselves. 3

4. Installation flow chart 1. Open the closure 2. Determine length of fiber cable to be fixed and stripped inside FOSC 3. Strip off s of fiber cable and fiber 4. Separate fiber cores and prepare work prior to fixing fiber cable 5. Fix reinforced core, and pyrocondense, fix and seal fiber cable 6. Splice fibers 7. Install heat shrinkable protective sleeve and house fibers 8. Check up comprehensively 9. Assemble FOSC housing and fix FOSC 5. The process of installing FOSC. 5.1 Step One - Open the closure 5.1.1 Cleaning the locale and determine where to install the FOSC and then place fiber cables required. 5.1.2 Check whether the main components and accessories have been well prepared 4

inside the package. 5.1.3 Open the closure 1 Demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop. 2 Pull the FOSC cover upwards out, installation could begin. 5.1.4 See Drawing 1 Important issues: If the weather condition is not good enough, then a tent must be pitched for waterproof and dustproof. Hoop (left) Hoop (right) Hoop connector Hoop fixing bolt FOST Fixing slot of heat shrinkable protective sleeve Grommet Hoop locking system Fiber holding tray Fixing shelf for FOST FOSC cover 90 ã FOST Grommet Base Seal fitting Fixing device for reinforced core Entry/exit tube(single) Entry/exit tube(mass) Drawing 1 5.2 Step Two -Determine length of fiber cable to be fixed and stripped inside FOSC 5.2.1 If all fibers are for branch splicing, please refer to Drawing 2(A) for stripping length. 5.2.2 If some fibers are for straight-through, while others are for branch splicing, please 5

refer to Drawing 2(B) for stripping length. 5.2.3 See Drawing 2. Important issues: 1. Reserve enough length of fiber cable to be spliced. 2. Stripping length also could be decided by customers according to installation requirement 90mm sealing and fixing length of fiber cable inside entry/exit tube Fiber cable 1720mm length of of fiber cable to be stripped off 120mm fiber with (the distance from fixing point of fiber cable to fixing point of FOST) 1600mm length of of fiber to be stripped off (to be spliced and winded inside the FOST Temp locating mark Drawing (2) A 90mm sealing and fixing length of fiber cable inside entry/exit tube 120mm length of fiber with (the distance from fixing point of fiber cable to fixing point of FOST) 100mm length of fiber with to be cut Fiber cable 1600mm length of of fiber to be stripped off (branching splicing) Temp. locating mark 1810mm length of fiber cable to be stripped off (for straight-through after being winded) Drawing (2) B Temp. locating mark 5.3 Step Three Strip off of fiber cable and fiber 5.3.1 Strip off of fiber cable from the temp. locating mark with the cutter and the stripper, please refer to Drawing 2 for stripping length. Stripping length also could be decided according to installation requirement 5.3.2 See Drawing 3. Important issues: If it is difficult to pull all the of fiber cable at one time, strip it off section by section to avoid fiber breakage. Entry terminal fiber cable Stripping terminal fiber cable Temp. locating mark Cutter Drawing 3 6

5.4 Step Four Separate fiber cores and prepare work prior to fixing fiber cable. 5.4.1 Wind 2 layers of insulation tape on of fiber core for protection. Meanwhile, get rid of the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and fix it on the fiber temporarily by adhesive tape. 5.4.2 Depending on fiber cable stripped, the following two cases are available. 1 All fibers are to be branched after being spliced completely. 2 Some of fibers are for straight-through after being winded, while the others are for branch splicing. 5.4.3 The FOSC is provided with 3 single entry/exit tubes which suit for single fiber cables with max. diameter ф20mm and 1 mass entry/exit tube which suits for 1 piece of fiber cable with max. diameter ф 20mm or 2 pieces of fiber cables with max. diameter ф 15mm or multi-pieces of fiber cables with short diameter. 5.4.4 Mass entry/exit tube is required if some fibers are for straight-through 5.4.5 The corresponding entry/exit tube cover could be slightly knocked out with screwdriver from inside to outside according to number and diameter of fiber cable required. 5.4.6 Reserve reinforced core in 70mm length and cut off the unnecessary ones. 5.4.7 See Drawing 4 and Drawing 5. Important Issues:Entry/exit tubes are to be selected accurately to make it easy for splicing and sealing. 7

Reinforced core Fiber with 70mm Fiber cable(1) Fiber cable(2) Reinforced core Fiber cable(3) Fiber with Drawing 4 Adhesive tape Fiber Adhesive tape Fiber Adhesive tape Fiber Straight-through fiber with 5.5 Fixation of reinforced core, and pyrocondensation, fixation & sealing of fiber cable. 5.5.1 Insert fiber cable into the corresponding heat shrinkable fixing tube, further insert the them into entry/exit tube at the bottom of FOSC. 5.5.2 Demount fixing nut of reinforced core with a special wrench (plastic one), which is to be inserted into the fixing slot afterward and tighten it. Then retighten it with a metal wrench (the metal wrench is to be provided by operator). 5.5.3 Hitch heat shrinkable fixing sleeve to the fiber cable till its root by hand. 5.5.4 Please refer to Drawing 5 for installing branching clip. 5.5.5 Heat shrinkable fixing sleeve with fire sprayer to make it hugging entry/exit tube and fiber cable to reach complete sealing. 5.5.6 See Drawing 5 important issue: 1. Fixing nut of reinforced core should be tightened. 2. While heating, heat shrinkable fixing tube should shrink evenly, and there should be no bubbles, pores and other defects inside the tube. 8

Adhesive tape Fiber Fiber FOST cover FOST Fiber with Adhesive tape Fiber holding tray Fixing device for reinforced core Base Heat shrinkable fixing sleeve(single) Entry/exit tube cover Straight-through Fiber with Fiber cable (1) Adhesive tape Fiber cable (2) Bracket Fiber with Fiber cable (3) Heat shrinkable fixing sleeve(mass) Fiber fire sprayer Drawing 5 Fiber Branching clip 5.6 Step Six - Splice fibers 5.6.1 Follow user manual of fusion splicing machine to splice fiber. Important issue: pay attention to the twist and bend of fiber 5.7 Step Seven -Install heat shrinkable protective sleeve and house fibers. 5.7.1 When having completed splicing the fibers, the first fiber ring should be housed on the farthest side of FOST, the remaining fiber optic should be winded, forming a ring with diameter not less than 80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve. ( Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring properly.) 5.7.2 see Drawing 6 Important issue: pay attention to the twist and bend of fiber. 9

Fiber (bunchy or ribbon) Fixing slot of heat shrinkable protective sleeve (bunchy or ribbon) Heat shrinkable protective sleeve (bunchy or ribbon) FOST Fiber (bunchy or ribbon) Nylon tie Nylon tie Fiber with Fiber with Drawing 6 5.8 Step Eight - Check up comprehensively To ensure the technical requirements, the following instructions must be followed: 5.8.1 Fibers with are fixed with nylon tie at the entrance of FOST. 5.8.2 Grommet should be pressed from inside to outside in order to properly install FOST. 5.8.3 Straight-through and reserved fibers with should be winded to the fiber holding tray. 5.8.4 Check whether the internal tighteners and fixing nut of reinforced core are well tightened. 5.8.5 Check whether seal fitting is installed neatly and smoothly. 5.8.6 Check whether heat shrinkable fixing sleeve is reliable and sealing completely. 5.8.7 See Drawing 7. Important issues: If any problems occur, they should be solved right away. 10

Grommet FOST cover FOST Nylon tie Fiber with Reinforced core Base Seal fitting Heat shrinkable fixing sleeve(single) Fiber cable(1) Fiber holding tray Straight-through fiber with Nylon tie Fiber cable(3) Fiber with Fixing device for reinforced core Earthing device Reinforced core Bracket Heat shrinkable fixing sleeve(mass) Branching clip Fiber cable(2) Drawing 7 5.9 Step Nine Assemble FOSC housing and fix FOSC 5.9.1 Put desiccant into FOSC. 5.9.2 Put FOSC cover on base directly. 5.9.3 Install plastic hoop between FOSC cover and base, tighten hoop locking system, which is to be fixed by hoop fixing bolt then. 5.9.4 FOSC installation 1 Aerial application: fix metal hoop and transom to the pole. Please refer to Drawing 8 2 Wall mounting application: fix the bracket on the wall with bolt. (metal hoop is not 11

required.) 3 Underground application: metal hoop is not required. 5.9.5 See drawing 8 Important issues: 1. Pay attention while installing plastic hoop. 2. The specification of bolt for fixing the bracket is M8. label FOSC cover Logo Hoop (metal) Fib er Opt ie Sp l i c e Closure Hooplocating bolt Hoop locking system Hoop (left) Transom (metal) Hoop (right) Entry/exit tube Heat shrinkable fixing sleeve(single) Fiber Cable Base Bracket (metal) Heat shrinkable fixing sleeve(mass) Branching clip Fiber cable Drawing 8 6. Fiber Optic Splice Closures (FOSC) inspecting and testing items Inspecting item Technical Requirements Inspecting type Routine test (Before leaving Type test factory) 12

Each small package contains one fiber optic splice Package closure, together with its accessories, tools, installation manual and packing list. Appearance Intact in shape, no burrs, bubbles, chaps, pores, warps, impurities and other defects, all background colors should full be even and continual. Sign There is a clear sign on the housing, such as name and model of the product, etc. The fibers reserved are to be winded in fiber optic splice Fiber storage device tray (FOST), the length of fibers housed in FOST is >1.6m, the curved radius is >30mm. During the installation and maintenance, there should be no attenuation on fibers. Electrical jointing device Inside FOSC: metallic components of fiber cables has the functions of electrical putting through, earthing connection and disconnecting. It is possible to install earthing deriving device outside the housing At least 3 sets After sealing according to the stipulated operation sampled Sealing performance procedures, the injected air pressure is 100KPa±5Kpa, when immersed in clean water of normal temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. After reopening and resealing according to the stipulated At least 3 sets sampled each time each time operation procedures, the injected air pressure is 100KPa Re-sealing ± 5Kpa, when immersed in clean water of normal performance temperature for 15 minutes, there should be no air bubbles, then observed for 24 hours, there should be no change of air pressure. Pull Bearing pull is 800N at axle orientation, there should be no breakage on the housing. Punching Bearing pressure of 2000N/10cm for 1 minutes, there should be no breakage on the housing Impact Bearing impact energy of 16N m, 3 times of impacts there should be not breakage on the housing Bending Torsion The spot between the FOSC and seal fitting can bear bending tension of 150N at bending angle of ±45 0 for 10 circles, there should be no breakage on the housing Bearing torsion 50N m, 10 circle at torsion angle±90 0, There should be no breakage on the housing. At least 3 sets sampled each time At least 3 sets sampled each time 13

Temperature circle Voltage resistance strength Isolating resistance Injected air pressure of 60KPa±5 KPa, the temperature circle ranging from -40 ~+65, 10 times of the circular tests (one circular consists of high temperature for 2 hours + indoor temperature for 2 hours + low temperature for 2 hours + indoor temperature for 2 hours ) when the pressure declines, the amplitude is 5Kpa, immerse the swatch in clean water of normal temperature for 15 minutes, there should be no air bubbles. After sealing the FOSC according to the stipulated operation procedures, immerse it in clean water of normal temperature in 1.5m depth for 24 hours, there should be no breakdown or arc over between the metallic components of the FOSC, between metallic components and the ground at DC 15KV for 1 minutes. After sealing the FOSC according to stipulated operation procedure, immerse it in clean water in 1.5m depth for 24h, the isolating resistance between the metallic components of the FOSC, between the metallic components and the ground should be 2 10 4 MΩ. 14

GUARANTEE: CONTACT: Address: Building 118, Vonsovskogo Street 1, Yekaterinburg, Russia Tel: +7(343) 379-98-38 Fax: +7(343) 379-98-38 E-mail: info@nag.ru Online shop: http://shop.nag.ru 15