Traceability overview

Similar documents
Calibration, Fluid Property Effects Reproducibility and Long Term Stability. All in 20 minutes! Dr Gregor Brown Cameron

Flow Research and Test Center. Creating resource technology for today and tomorrow.

Calibration of Pipe Provers in the field

Flow Research and Test Center

Global Flow Measurement Calibration Consistency

Intercomparison Between Trapil, France and NEL, UK Using Oil Flow Turbine Meters

Preparing the New EuroLoop Liquid Flow Facility for Accreditation. Jos van der Grinten - NMi EuroLoop

National comparison on verification of fuel dispensers

Legal Metrology Control of a Liquefied Petroleum Gas Transfer Standard and Field Practice

OIML Weights & Weight Sets

DFX Series Liquid Ultrasonic Flow Meters

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

Proving Liquid Ultrasonic Flowmeters Summary of Testing Conducted January 2011

HTM Series Helical Turbine Meters

EI HMC Report Spring API Committee on Petroleum Measurement Standards Meeting

HERMAN HOFSTEDE. Sales Director, KROHNE Oil & Gas

Determination of Volume Correction Factors for FAME and FAME / Mineral-diesel blends

Small hydrocarbon flow calibration facilities at NMIJ

UNDERSTANDING CMM SPECIFICATIONS AND CALIBRATION METHODS

DFX series. High-end Ultrasonic Flow Meters for Liquid Hydrocarbons Custody Transfer. 32 beams for ultimate performance

CALIBRATION SYSTEM CERTIFICATE

LIQUID MEASUREMENT STATION DESIGN Class No

Certificate of Calibration

Research on the micro liquid flow standard system and inter-comparison

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

ASTM E74-13a Explained

Product Loss During Retail Motor Fuel Dispenser Inspection

Report on Recent Activities: CMS/ITRI, Chinese Taipei (Taiwan)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

A Guide to Dry Block Calibration

California Department of Food and Agriculture Division of Measurement Standards Petroleum Products Program Fuels and Lubricants Laboratory

For the National Voluntary Laboratory Accreditation Program

Test Method D5967 Mack T-8. Version. Method: Conducted For

Industry 4.0 Is Unthinkable Without Calibration!

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Technical capability. Innovation R&D. Global Collaboration

Standard Calibration Certificate

A Comparison of Boat Introduction and Direct Injection using the Thermo Scientific ipro 5000 Series Combustion Analyzer

A PORTABLE SYSTEM FOR THE CALIBRATIONOF TRANSDUCERS AND TORQUE WRENCHES: THE CALIBRATION BELL

Standard Calibration Certificate

INFLUENCE OF CROSS FORCES AND BENDING MOMENTS ON REFERENCE TORQUE SENSORS FOR TORQUE WRENCH CALIBRATION

ISO 9001 : Dual Plate Wafer Check Valves. API 594 Design API 598 Tested. Maximizing the Flow

Field test for the comparison of LNG static and dynamic mass measurement methods

Carl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C

INSTRUCTION MANUAL FOR TANK CAR AND TANK TRUCK GALLONAGE COMPUTATIONS FROM NET WEIGHTS

Final report of. Key Comparison CCQM-K1

Laboratory Accreditation Programmes

Certificate of Accreditation

STATUS OF THE WORKING GROUP FOR FLUID FLOW JOHN WRIGHT NIST FLUID METROLOGY GROUP CHAIR WORKING GROUP FOR FLUID FLOW MAY 18, 2017

Stainless Steel Precision Weights and Weight Sets

Experiment (4): Flow measurement

Of Petroleum Measurement Standards Chapter 11 1 Volume Correction Factors

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

MISHAAL ALANZI Gas Engineer, KOC

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Development of metrological standards for traceable particle number measurements of automotive exhaust emissions

D I S T R I B U T E D V A L V E S. Super G Lubricated-Non-Lubricated Plug Valve TEXSTEAM

THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC)

PBV s Engineering Excellence At Work

Paper 1.4. EXPERIENCES WITH THE MASTER METERING PRINCIPLE AND ULTRASONIC FLOWMETERS AT OFFSHORE LOCATIONS (FPSO s) John Thorogood KROHNE Oil & Gas

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

powerperfector Voltage Power Optimisation

TIER 3 MOTOR VEHICLE FUEL STANDARDS FOR DENATURED FUEL ETHANOL

LM Test Report for OSRAM SYLVANIA INC. 100 Endicott Street Danvers, MA 01923

QUESTION / CLARIFICATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Update on the UN-ECE Particle Measurement Programme (PMP)

IMGC-CNR Activities to Improve the Force Chain in Italy. C. Ferrero and C. Marinari Istituto di Metrologia G. Colonnetti (IMGC-CNR) Torino - ITALY

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

BS EN ISO 9001 FM Worcester Controls 5 Series BS 5351 Approved Flanged Ball Valves

BARTON 7400 Precision Gas Turbine Flow Meters

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Liquid Turbine Flowmeters

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

Technical Report. 10 th Round Robin Test for Multi-Capillary Pressure Drop Calibration Standards (2014)

Turbine Meters. df5/99 TRZ

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

European Metrology Programme for Innovation and Research (EMPIR) Kamal Hossain EURAMET Chairperson

LIQUID MEASUREMENT STATION DESIGN with NGL CONSIDERATIONS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

Euromet Project No. 419

AN INNOVATIVE APPROACH TO INCREASE DIAGNOSTIC SENSITIVITY IN ULTRASONIC FLOW METERS

Healthweigh. Rice Lake Weighing Systems

ELASTOMERIC ISOLATORS

Overview about research project Energy handling capability

Selecting Weights and Certificates

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

WET GRIP TEST METHOD IMPROVEMENT for Passenger Car Tyres (C1) GRBP 68 th session

Hans-Paul Siderius Chairperson 4E. London, 14 September 2010

Optidew Vision Optical Dew-Point Meter

PFS-FN FEATURES: * ASME & ISO RECOGNIZED * * WIDELY ACCEPTED TEST STANDARD * * RELIABLE PERFORMANCE HISTORY * * ACCURATE METERING SOLUTION *

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Transcription:

Traceability overview Weighing scale and traceable calibration weights from ISO17025 accredited supplier Pipe prover calibration by VSL (NMI Netherlands) Turbine master meter - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Ultrasonic master meters Small volume prover calibration by VSL (NMI Netherlands) Meter Under Test calibration by Cameron ISO17025 internal procedure

Uncertainty analysis example

Major contributors to uncertainty Prover base volume Coefficient of thermal expansion for the liquid Delta temperature between prover and meter under test Delta temperature for connecting volume

NVLAP Certified Uncertainties 10 to 750 m 3 /hr Small volume prover 0.03% Turbine master meter 0.04% 150 to 2200 m 3 /hr Ball prover 10 m 3 0.04% Ball prover 3.3 m 3 0.07% One master meter 0.09% 600 to 3900 m 3 /hr Two master meters 0.08%

Comparison of ISO17025 capabilities 0.25 0.20 Cameron CUTC TUV NEL TRAPIL SPSE 0.15 0.10 Uncertainty(%) 0.05 0.00-0.05-0.10-0.15-0.20-0.25 0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 Flow rate (m 3 /hr)

Key standards and documentation International Standards Organisation ISO17025:2005 General requirements for the competence of testing and calibration laboratories Joint Committee for Guides in Metrology JCGM 100:2008 (GUM 1995 with minor corrections) Evaluation of measurement data Guide to the expression of uncertainty in measurement API Manual of Petroleum Measurement Standards Especially the subchapters of Chapter 4 - Proving Selected ISO and ASTM standards

Calibration laboratory management system Independent quality system accredited for conformance with ISO17025 Calibration laboratory quality manual comprising 28 documents Plus 26 documented operational procedures

Master meter long term stability Master meters are calibrated before use Long term stability gives a good indication that everything is working as expected

Master meter long term stability 1.0050 Time Vs MF bar For 10 inch 280C MM1 for the following Re 10,000 56,234 100,000 562,341 1,000,000 1.0040 1.0030 1.0020 1.0010 MF bar 1.0000 0.9990 0.9980 0.9970 0.9960 0.9950 9/1/2007 3/19/2008 10/5/2008 4/23/2009 11/9/2009 5/28/2010 12/14/2010 7/2/2011 1/18/2012 Date

Temperature control Temperature ( C) 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 SPSE Trapil Cameron - 35 deg C set point Cameron - 20 deg C set point TUV NEL - 20 deg C set point 0 10 20 30 40 50 60 70 80 90 100 Time (minutes)

Intercomparison with NEL (UK) ISO 17025 states that Participation in a suitable programme of interlaboratory comparisons is required where possible Flow intercomparisions involving multiple laboratories are rare and tend to involve national measurement institutes However, NEL in the UK had been designated at pilot lab in the recently completed Liquid Hydrocarbon Flow Key Comparison CCM-FF-K2, carried out under the auspices of the International Committee of Weights and Measures (CIPM)

Intercomparison with NEL (UK) Other participants in CCM-FF-K2 were: CMS (Chinese Taipei), NMIJ (Japan), NMi VSL (Netherlands), FORCE (Denmark), and SP (Sweden) Therefore by carrying out a bi-lateral intercomparision with NEL, a successful result would demonstrate metrological equivalence with a broad group of national metrology institutes

Key Comparison CCM-FF-K2 results

Intercomparision package An intercomparision package was assembled using two 6-inch Caldon 8-path meters A flow conditioning upstream section was used to ensure absolutely minimal installation effects Flow A B C D E F G A and G B C D & F E 5D straight length (matched schedule with internal welds ground flush) Perforated plate flow conditioner (CPA) 15D straight length (matched schedule with internal welds ground flush) 280Ci ultrasonic flow meters 3D 150# to 300# flange adaptor spool

Intercomparision package Cameron NEL, UK

Intercomparision package Primary comparison was carried out using kerosene substitute (Exxsol D80) over a flow range of 100 to 600 m 3 /hr in both facilities Cameron lab tests vs ball prover NEL tests versus turbine secondary standards A secondary comparison was also carried out using the NEL water flow facility gravimetric standard Comparisons were made at overlapping Reynolds numbers

Intercomparision results on kerosene 0.15% 0.10% Meter 1 Meter 2 Combined uncertainty acceptance limits 0.05% Difference (%) 0.00% -0.05% -0.10% -0.15% 4.9 5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Log Reynolds number

Intercomparision results vs water 0.15% 0.10% 0.05% NEL oil data compared to Cameron oil calibration NEL Water data compared to Cameron oil calibration Combined uncertainty acceptance limits Difference (%) 0.00% -0.05% -0.10% -0.15% 4.9 5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Log Reynolds number

Intercomparision results The results from both meters and both NEL facilities (oil and water) demonstrated metrological equivalence with the Cameron laboratory The closest and most linear agreement was actually found in the case of the water comparison, suggesting that the difference in the oil calibration were in part due to the curve fitting to the NEL secondary standard turbines

SUMMARY The Cameron laboratory as constructed exceeds the design expectations It offers a capability that surpasses that of the third-party facilities previously used The uncertainty has been validated by VSL, NVLAP and the NEL intercomparision Use of well understood and reliable system components and methods have resulted in a high availability the laboratory is in almost constant use

Thank you gregor.brown@c-a-m.com