IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

Similar documents
POSITIVE DISPLACEMENT FLOWMETER

HG 20F-012E-01 OIL CONTROL GUN

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )

Positive Displacement Flowmeters GM020 series instruction manual

POSITIVE DISPLACEMENT FLOWMETERS

Positive Displacement Flowmeters GM007 series instruction manual

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )

Positive Displacement Flowmeters GM020 series instruction manual

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1

OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications

POSITIVE DISPLACEMENT FLOWMETERS

INSTRUCTION MANUAL MN7 series

Operating Instructions for Oval Wheel Flowmeter. Model: DOC

OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters

The experts in fluid technology

MX06 - MX100 OVAL GEAR FLOWMETER SERIES

The experts in fluid handling

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

MODEL MX75 3 OVAL GEAR FLOWMETER

The experts in fluid technology

MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS

Installation & Operation Manual

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

Positive Displacement Flowmeters GM50 series instruction manual

The experts in fluid technology

Positive Displacement Flowmeters GM515 series instruction manual

MODEL MX12 1/2 OVAL GEAR FLOWMETER

Positive displacement flowmeters GM001 series instruction manual

OVAL GEAR Medium capacity positive displacement Mechanical flowmeters. Model: ½ (15m m)

ADTFM-im -issue INSTRUCTION MANUAL DIGITAL DIESEL METER ADTFM

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

OVAL GEAR. Medium Capacity Positive Displacement Mechanical Flowmeters. Models: 1 (D-150), 1½ (D-250), 2 (D-450) & 2" (D-580)

OVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)

fusion RF Control Handle

M4 Troubleshooting 42

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

MX-SERIES OVAL GEAR FLOW METERS

Positive displacement flowmeter for continuous flow measurement

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

I N S T R U C T I O N M A N U A L 3 (080), 3 (080E), 4 (100), & 4 (100E)

OWNER S TECHNICAL MANUAL

Positive displacement batch controller

OMP POSITIVE DISPLACEMENT FLOWMETERS

I N S T R U C T I O N M A N U A L

I N S T R U C T I O N M A N U A L

OVAL GEAR. Medium capacity positive displacement Pulse flowmeters I N S T R U C T I O N M A N U A L

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

POSITIVE DISPLACEMENT FLOW METERS

Industrial OG meter series IOG Inline and flanged oval gear meter

POSITIVE DISPLACEMENT FLOW METERS

Electronic Preset Meter. Model EPM2-ADV-SF, Advanced Series, Special Fluids. User Manual. AUT-UM EN-05 (August 2015)

OMP Positive Displacement Flowmeters

FIRE HYDRANT/HOSEREEL PORTABLE TESTER

macnaught flow measurement

macnaught flow measurement

Wisdom Systems. SCR Urea/Adblue Transfer System. Operating Instructions. Outstanding Features. Chemical Transfer and Application Technology

macnaught flow measurement

RUN ACCUM. TOTAL STOP BAT LOW HIGH

1 in., 1.5 in., and 2 in. electronic high flow meter

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

DIGITAL OIL PRESET METER OWNER S MANUAL

MODEL 900 IMPELLER-TYPE FLOW METER

Model TUR-200D Turbine Flowmeter

IN-LINE IN-LINE 12V pulses version

Ph: (07) Fax: (07) Pump Manual

OVAL GEAR Medium capacity positive displacement flowmeter

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Technical Data. Series Oval Flowmeter. Model 9400

PORTAGAUGE 4 USER MANUAL

Series TTMP PVC Electronic Totalizing Meter

Liquid Turbine Flow Meter OwnerÊs Manual

MODEL 200 MULTI-JET FLOW METER

12 French Drive Mono, ON Canada L9W 5W1 Ph Toll Free Fax

FTB380 SERIES Aluminum Turbine Flowmeters

OVAL GEAR Medium capacity positive displacement flowmeters

Instruction Manual RZ POSITIVE DISPLACEMENT FLOWMETERS 2AU

High Accuracy Mechanical Fuel meter FM-100

Instruction Manual. RZ Positive Displacement Flowmeters 2AU

Flow meter Type Recordall (RCDL)

High Lift Transmission Jack

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

User Manual for the ProFlow 1K Release: User Manual for the ProFlow 1K_Rev_A PVA Support Hub. User Manual for the ProFlow 1K

Electronic lube meter

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

Industrial Grade 09 COMPUTER ELECTRONICS. Owner s Manual

Industrial Turbo Meters, Sizes 2" through 6"

LD Series Electronic Meters

perma STAR VARIO Operators pocket guide

MODEL 1100 TURBINE FLOW METER

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

OVAL GEAR Medium capacity positive displacement pulse flowmeter. Size : ½ ( 015mm)

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Positive displacement flowmeter

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

Operating Manual Model- P282 Digiflow Controller

Transcription:

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist you in the operation and maintenance of this product. If you have any problems with the meter, refer to the maintenance and trouble shooting sections of this manual. This manual contains connection and operating instructions for meters with Liquid Crystal displays (LCD). If you need further assistance, please contact your local representative or distributor for advice. This Flow Meter has incorporated the oval rotor principal into its design. This has proven to be a reliable and highly accurate method of measuring flow. Important Information WARNING Before use, confirm the fluid to be used is compatible with the meter. Refer to Industry fluid compatibility charts or consult your local representative for advice. Operating Principle When fluid passes through the meter the rotors turn, as shown below. The magnets which are located in the rotors will pass across the PCB sensors. A signal is generated which is then sent by the PCB to the relevant LCD, or receiving instrument as a Pulse Output. Exceptional repeatability and high accuracy over a wide range of fluid viscosities and flow rates are features of the oval rotor design. With a low pressure drop and high pressure rating oval rotor flow meters are suitable for both gravity and pump (in line) applications. IM213D-MC Issue 7 2013 Page 1 of 8

Operational Overview 1. During normal operation the 6 Figure LCD display will appear as per the example diagram below. 2. Pressing the blue Mode button will cycle through options available dec.1 = 1 Decimal Place dec.22 = 2 Decimal Places dec.333 = 3 Decimal Places 3. To move to the next section (Unit) press the red Reset button Setting the Units for both Batch & Total. 1. The LCD will now display UNIT. See Operational Overview. 2. Pressing the blue Mode button will enable the operator to toggle between the following two Display options. Batch Total 3. The Batch total can be reset by pressing the red Reset button. Please note: This function resets the Batch only. The Total displayed is unable to be reset. 4. A Sleep mode has been incorporated in the meter to prolong battery life. The unit will activate sleep mode after 30 secs without use. Programming Instructions Note Any changes made during the programming phase will automatically be Saved when the unit is returned to the operation mode. Accessing Programming Menu To enter in the programming Menu, press the reset button for 5 secs. Once in the programming menu the operator will be able to access (and adjust) 3 programming selections. 1- Setting Decimal Place 2- Display Units of measurement 3 - Calibration Mode Setting the decimal place. 1.The unit will display the mode and the number of Decimal Places currently set. E.g. dec.22 2. Pressing the blue Mode button will cycle through the options of units that can be displayed for Batch. L GAL Qt Pt Oz dl 3. Next press the red Reset button to move onto setting the Total units. The availible unit options are as shown above. 4. Once the required Units have been selected move to the next section (Calibration) by pressing the Red Reset button. Calibration. The calibration mode enables, in the case the operator suspects the accuracy of the meter is in question, the operator to dispense a known volume of fluid through the meter (Test Volume) This Test Volume is compared to the volume measured by the meter (Measured Volume). The meter will perform an Auto Calibration if applicable. 1. The unit will display CALIBRATE in the lower left hand corner, and a number on the main display. The following options can be scrolled through by pressing the blue Mode button 2 4 8 20 100 250 This number represents the Test Volume to be dispensed through the meter during Calibration. IM213D-MC Issue 7 2013 Page 2 of 8

Programming Instructions 2. On selecting the Test Volume press the blue Mode button for 3 secs. The meter will display PURGE and CALIBRATE will also start to flash. 3. Purge the system of air by running fluid through the system. 4. Once purged of air the calibration process can be started by pressing the blue Mode button. The unit will display RUN and the Test Volume. E.g. RUN 100 5. Run the Test Volume through the meter until stipulated volume has been reached (e.g. 100). 6. Once this volume has been reached press the blue Mode button to stop the test. The unit will now compare the Measured Volume to the Test Volume and perform an Auto Calibration if the difference between the two volumes are within ± 8% of each other. 4. Remove the rotors (item 6) and inspect the condition of each. Also investigate if there is the presence of any foreign material in the meter body, that may inhibit the rotors performance Reassembly 1. Please note, the design of the rotor and shaft assembly ensures that the rotors can only be re-installed with the correct orientation. (i.e. with the magnets being in close proximity to the Electronic module). When replacing the rotors the top face of the rotors should be flush with the sealing face of the meter body. If they sit higher than the sealing face remove, turn over and replace. 2. Replace the rotors (Item 6) onto the shafts at 90 degrees to each other (as per diagram below) and check their operation by turning either of the rotors. If the rotors are not in mesh correctly or do not move freely, remove one of the rotors and replace correctly at 90 degrees to the other rotor. Note: If the difference between the two volumes is greater than ± 8% of each other, the unit will display one of the following messages.. ERROR LOW ERROR HIGH if these messages are displayed please contact your Macnaught agent for advice. Returning to Operation Mode At any stage the unit can be returned to the Operation mode by pressing the red Reset button for approx. 3 secs. Any program changes will automatically be saved. Maintenance Procedures. Disassembly Ensure that the fluid supply to the meter is disconnected, and the line pressure is released before disassembly, with the exception for repair or maintenance to the LCD or PCB where it is not necessity to isolate the meter from flow. Refer to the exploded parts diagram on subsequent pages for item numbers. 1. Pull off protective boot (item 1) and unscrew the four retaining screws (item 2) next remove the Electronic Module (item 3) 2. Check for evidence of moisture into the electronic housing. If there is evidence of this, check the condition of the O-Ring (item 4) 3. To access the Rotor assembly, remove the 8 Meter Cap screws (item 9) 3. Check the Rotors (item 6) rotate freely. 4. Replace the 0-Ring (item 7) into the groove of the Meter Cap (item 8). 5. Replace the Meter Cap onto Meter Body (item 5) Tighten Meter Cap screws (item 9) in a diagonal sequence E.g. 1, 5, 3, 7, 4, 8, 6, 2 6. Place the O-Ring (item 4) into the Electronic Module (item 3) and mount the Electronic module onto to the Meter Body 7. Replace and tighten the Retaining Screws (item 2) in diagonal sequence. 8. Align and push on the protective boot (item 1) onto the electronic module (item 3). 9. Before returning to service test the meter by turning the Rotors with your finger. Or applying a very low air pressure (no more than a good breath) to the meter IM213D-MC Issue 7 2013 Page 3 of 8

Maintenance Procedures Changing the Battery. A Low Battery warning will be displayed on the LCD screen when there is 5% power left. The warning will remain active until the battery is replaced. 1. See Disassembly procedure. Follow step 1 to isolate the Electronic module. 2. See Photograph below. Remove the PCB from clear plastic housing by unscrewing the 3 retaining screws. 3. The battery can now be removed by placing a screw driver into the slot (slot indicated by arrow) on the PCB and easing the battery free from its compartment. 4. Replace with a new CR2450 Lithium battery. Battery Slot Reed Switch Please Note: Not dependant on Polarity Yellow Green IM213D-MC Issue 7 2013 Page 4 of 8

Exploded Diagram Spare part kits Order for replacement Item no No off Part or Set Description 1 1 IM215s Protective boot 2 7 Screw M3 x 8 Pan Hd 3 1 DKIT-IM012-MC Electronic module 4 1 O'ring (BS040) 5 1 n/a Body 6 2 MKIT-IM012-01 Rotor 7 1 O'ring (BS035) 8 1 n/a Cover plate 9 8 n/a Screw M4 x 16 Pan Hd IM213D-MC Issue 7 2013 Page 5 of 8

Meter Dimensions Notes IM213D-MC Issue 7 2013 Page 6 of 8

Troubleshooting Guide Problem Cause Remedy Fluid will not flow through meter a) Foreign matter blocking rotors b) Damaged rotors c) Meter connections over tightened d) Fluid is too viscous a) Dismantle meter, clean rotors b) Replacement rotor assembly required. c) Re-adjust connections d) See specifications for maximum viscosity Reduced flow through meter Meter reading inaccurate a) Partially blocked b) Fluid is too viscous a) Fluid flow rate is too high or too low b) Air in fluid. c) Excess wear. a) Check and clean meter. b) See specifications for maximum viscosity a) See specifications for minimum and maximum flow rates b) Bleed air from system c) Check meter body and rotors. (see instructions) Meter not giving a pulse signal LCD register not working a) Faulty hall effect sensor b) Faulty reed switch c) Magnets failed a) Battery flat b) Faulty LC Display a) Replace PCB Board b) Replace PCB Board c) Replacement rotor assembly required a) Replace battery b) Replace PCB module IM213D-MC Issue 7 2013 Page 7 of 8

Product Specifications Accuracy + / - 0.5% of Reading Type Oval Gear Flow rate 1 Ltr -30 Ltr (0.26-8 US Gal) per minute Maximum Pressure 6900kPa / 1000psi / 69 Bar Suitable for use w ith : Engine Oil, Diesel Oil, Automatic Transmission Fluid (Maximum Viscocity SAE140), Ethelene Glycol Based Anti-Freeze / Anti-Boil mixture (Max 50% w ater) Wetted Materials Acetal, Aluminium, Steel, Nitrile Rubber Connections 1/2" BSPT or 1/2" NPT Maximum Temperature 55 deg C (131 deg F) Minimum Temperature -14 deg C ( 6.8 deg F ) Maximum Viscosity 1000cP (Centipoise) Re-settable 'Batch' Total 99999.9 Non-Resettable Total 999999 * When tested with lubrication oil @ 25 C. Allowances should be made for changes to these parameters. IM213D-MC Issue 7 2013 Page 8 of 8