Fan Powered Low Profile Variable Volume Terminal Units

Similar documents
INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

LDV / LDVQ 5000 AIR VOLUME CONTROL VALVE INSTALLATION MANUAL. Date: 02 / 10 Reference # : F-36. w w w. p r i c e - h v a c. c o m

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

University of Delaware

SECTION AIR TERMINAL UNITS

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

VAV Terminal Unit Control Package

AIR FLOW SOLUTIONS. MODEL QST Quiet, Series (Continuous) Flow VAV Terminal Unit. MODEL QPT Quiet, Parallel (Intermittent) Flow VAV Terminal Unit

NECO Pumping Systems

General Information... 2

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Products for Indoor Air Quality and Control

Start-Up, Operation and Service Instructions

Variable Air Volume (VAV) Pressure Independent Control

IOM 002 Effective 12/17 A I R D I S T R I B U T I O N M O D E L Q S T M O D E L Q P T M O D E L E S T

FAN POWERED TERMINAL UNITS

Variable Air Volume Dampers

HOW TO SPECIFY SDV UNITS

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

SECTION AIR INTAKE SYSTEM

Hoffman Controls. Installation & Operating Instructions. General. Installation. Determining Damper Shaft Rotation. Stop Pin Installation

Fan - Powered Terminal Unit Series Flow

Air Handling Unit Construction Checklist

High Performance Fan Coils FCHG Genesis Series Horizontal

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

MANUAL INSTALLATION. Venturi Valve. VV Series. v203 - Issue Date: 03/25/ Price Industries Limited. All rights reserved.

SINGLE DUCT TERMINAL UNITS

(For serial numbers before w/ analog control)

Installation and Operation Instructions

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

catalog SDL Single-Duct, Low-Height, VAV Terminals

FOR USE IN SOLUTION AIR HANDLING UNITS

FAN POWERED TERMINAL UNITS

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

catalog SDL Single-Duct, Low-Height, VAV Terminals

SERIES ARH INSTALLATION AND OPERATION INSTRUCTIONS FOR THE HORIZONTAL AUTOROLL & MANUROLL

SERVICE MANUAL (INTERNATIONAL)

Introduction. System Components

PARTS & SERVICE MANUAL

SCR Power Controllers

PIM Pressure Independence Module

MODEL SCA Installation and Operation Manual Important:

RETROFIT TERMINAL UNITS

SERIES 700 ANALOG ELECTRONIC CONTROLS

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

Pump Installation and Service Manual HRS Hydromatic Retractable System

Safety & Installation Instructions

ATP-2040 Electric Damper Actuator/Transmitter

Pneumatic Controls. Pneumatic Controls Sections

INSTALLATION INSTRUCTIONS

Model 116 DPI Switch Installation and Operating Instructions

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

I Fan Powered Terminal Unit

TSS Single-Duct VAV Terminals

348002K/348012K Manifold Block Style Service Manual 12/2000

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Powers TM Controls SW 141 Differential Static Airflow Switches

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Dual Duct Variable Air Volume Terminal (Model TDS)

Instruction Bulletin. Jockey Pump Controller

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

LC I LIPPERT COMPONENTS HYDRAULIC FULL WALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL

PIM Pressure Independent Module

Installation, Operation and Maintenance Manual

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

INSTALLATION INSTRUCTIONS

System 350 P352AB Electronic Pressure Control Series

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

SERVICE MANUAL (INTERNATIONAL)

KEES, INC. BALANCING MANUAL

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Syntron EB-00 Vibratory Parts Feeder GENERAL MANUAL

X100P Load Bank. Read all instructions before using the load bank. Contents

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Embedded Rack Slide-out System

NJK Precision Product NJK-02 Sensor Installation Guide

Electric Furnace KF/KFS Series

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

INSTALLATION AND OPERATION MANUAL ARM-4073 AUTOMATIC REPRESSURE MODULES

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Hydro-Sync Slide-Out System

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Transcription:

MANUAL INSTALLATION Fan Powered Low Profile Variable Volume Terminal Units FEVLP / FPVLP / FDVLP Series v001 Issue Date: 07/19/16 07/19/16 Price Industries Limited. All rights reserved.

TABLE OF CONTENTS Product Overview General...1 Caution To Contractors...1 Receiving Inspection...1 Control Assembly Label...2 Installation & Mounting Instructions Mounting The Unit...3 Electrical Connection...4 Duct Connection...4 Control Connections...4 Maintenance...5 Filter(s)...5 Air Balancing Procedure...5 ECM Motor Adjustment...6 Operating Guidelines...6 Fan Performance Curves - FEVLP, FPVLP, FDVLP - Standard Motor...7 Fan Performance Curves - FEVLP, FPVLP, FDVLP - ECM Motor...8 Electronic Airflow Adjustment Procedure...10 Calibration Procedure for Velocity Adjustments made at Thermostat...10 Airflow Adjustment Procedure...11 Electronic Calibration Curves and Equations...12 Pneumatic Calibration Procedures...13 General...15 DDC Calibration Procedures...15 Airflow Sensor...16 Maintenance Troubleshooting Guide...17 Replacement Parts...18

PRODUCT OVERVIEW General Price Fan Powered Low Profile Terminals are available with pneumatic, electronic or Direct Digital (DDC) Controls. In most cases pneumatic and electronic controls are factory supplied and mounted. In the case of DDC controls, the terminal unit controls are often supplied by the controls contractor and either factory or field mounted. For information concerning controls, components, sequence of operations, etc. for DDC controls supplied by the controls contractor, please refer to the documentation provided by the controls contractor. Damper rotation is always clockwise to the open position. An identification mark on the end of the shaft indicates the damper position. Capped tees are provided in sensing lines from the amplifying sensor. These allow field connection of differential pressure gauge for accurate airflow measurement (not applicable with electronic controls). An optional metal control cover may be provided to protect the terminal unit control components. The protective cover is removable with two sheet metal screws. The velocity sensor is normally supplied as standard with the terminal unit. However, in some cases a flowsensing device supplied by the controls contractor may be field or factory mounted. Refer to the submittal drawing for illustration. Caution To Contractors 1. Fan Powered Terminal Units are not intended for use as temporary heat or ventilation sources during building construction. The terminal units are not designed nor equipped to operate in a dusty construction environment. Recirculating fan wheels can become coated in construction dust, resulting in an unbalanced wheel. This in turn can contribute to reduced motor life. Inlet air filters, if supplied, would provide little protection as they would quickly become plugged with construction dust. 2. A Fan Powered Terminal Unit should never be operated if the downstream ductwork has not been installed. A minimum of 0.10 in. w.g. downstream static pressure resistance is required for safe operation of the fan motor. Units with electric heat require 0.20 in. w.g. for stable operation. NOTE: Price cannot warrant against unauthorized operating conditions as outlined above. Receiving Inspection All Price Fan Powered Terminal Units are inspected before shipment. After unpacking the assembly, check it for damage. If any damage to the products is found, report it immediately to the delivery carrier. During unpacking and installation, do not handle the unit by the inlet velocity sensor. Caution is required when unpacking the fan powered units with electric coils as not to damage the elements. WARNING: Do not adjust the control components FAN POWERED TERMINAL UNIT priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 1

PRODUCT OVERVIEW Control Assembly Label All Price Fan Powered Low Profile Terminal Units are tagged with a control assembly label as shown on the right. This label identifies the model number, location tag #, controller type, actuator type, thermostat action, damper action, application and controller setpoints. Options, accessories and appropriate control diagrams are also identified. If field adjustment of the controller setpoints should become necessary, follow the appropriate procedure outlined in this manual. NOTE: All pneumatic controls must be calibrated in the position they are mounted. All factory-supplied controllers are tagged with a controller label as shown below. This label identifies the required sensor velocity pressure for both the minimum and maximum controller setpoints. CONTROL ASSEMBLY LABEL CONTROLLER LABEL 2 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

Mounting The Unit 1. Use trapeze hangers or optional hanger brackets (shipped loose) as illustrated. Hanging rods should be securely attached to joists or to mounting anchors, which are properly secured to slab construction with lugs, or poured in place anchors. Trapeze bars should be positioned within 3 in. (76 mm) of the discharge end and 2.5 in. (63 mm) of the inlet end to allow for access panel removal. 2. Price Fan Powered Low Profile Terminal Units are designed to be mounted in the direction indicated by the Control Assembly Label found on the protective shroud. 3. Do not block the bottom access panel - maintain clearance for blower service. Correct installation of the trapeze bars will not block access panel removal. 4. Do not install tight to slab, avoid contact with other obstacles such as rigid conduit and sprinkler piping. This can cause excessive vibration and noise transmission. 5. Install the unit in a location that allows free access to the unit as well as all control components. 6. Ensure main power to the terminal and electric coil has been disconnected prior to performing any electrical work or inspection of the circuitry. 7. When mounting hanger brackets to an electric coil, do not use screws longer than 3/4 in. (19mm). WARNING: Do not tamper with control components. CAPTION OPTIONAL HANGER BRACKETS OPTIONAL HANGER BRACKETS TRAPEZE HANGERS 3/4 X 3/4 X 1/8 (19 mm x 19 mm x 3.2 mm) ANGLES MAINTAIN 8" (0.2 M) CLEARANCE FROM AIR TERMINAL AND/OR CONTROL SHROUDS TO SUPPORT RODS ISOLATION PADS BETWEEN TRAPEZE AND TERMINAL USE 5 16 OR 3 8 (7.9 MM OR 9.5 MM) DIAMETER HANGING ROD ELECTRIC HEAT 3 (76 mm) OR LESS 5/16 OR 3/8 (7.9 MM OR 9.5 MM) DIAMETER HANGING RODS MINIMUM 3 DUCT DIAMETERS STRAIGHT DUCT ON INLET DO NOT BLOCK ACCESS TO CONTROLS 6 (152 mm) OR LESS DO NOT BLOCK BOTTOM ACCESS PANEL NOTE: INSTALL AIR TERMINALS LEVEL WHEN EQUIPPED WITH VELOCITY PRESSURE CONTROLLERS. priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 3

Electrical Connection CAUTION: Disconnect all incoming power before any electrical installation or service is performed on the unit(s). 1. All field wiring is to be in accordance with the National Electrical Code ANSI/NFPA No.70 or the Canadian Electrical Code, Part 1, CSA Standard C22.1. 2. Refer to the product identification label on each unit for information to determine the field wire size. 3. Check voltage requirements prior to power supply connection. Refer to the electrical label located near the electrical control box and also refer to the schematic drawing provided on the underside of the electrical control box cover. 4. If, upon energizing the electric motor, excessive noise is apparent, shut down the unit. Determine the cause by checking for packing materials, etc. and re-energize after corrective action has been taken. 5. If an Electric Reheat Coil has been supplied, refer to the electrical schematic, which is permanently affixed to the underside of the electrical control cabinet door, prior to hook-up. Check the voltage requirements to ensure proper voltage supply is used. CAUTION: For three phase power connections, be sure to account for fan motor load. Phases must be balanced accordingly. 5. For motors a minimum of 0.1 in. w.g. downstream static pressure is required to prevent overheating of the fan motor. For units with electric heaters a minimum of 0.2 in. w.g. is required. Control Connections Pneumatic 1. External control air connections are provided for main air and thermostat hook-up. These are to be piped according to the label on the control shroud. 2. Main air supply must be clean and dry, delivered at 15 to 25 psi (maximum 25 psi). 3. Ensure that lines are not crimped or cut when installed. Electronic A wiring diagram is provided with each assembly. Follow the diagram for wiring of the thermostat and other accessories. Digital If controls have been factory mounted, a wiring diagram will be included with the unit indicating the factory-mounted components. For field wiring of room sensors and other accessories, refer to the controls contractor s documentation for all wiring information. Duct Connection 1. Recommend a minimum of 3 duct diameters of straight inlet duct, either sheet metal or flexible, same size as the inlet, between the unit inlet and any transition, take-offs or fittings. Use of transitions or elbows at the unit inlet to be avoided. Where flexible duct is used it should be pulled tight to eliminate sags or folds. 2. To control radiated noise in critical applications, it is recommended that the inlet ducts be fabricated of minimum 24 gauge sheet metal in place of flexible ducts. 3. To prevent excessive air leakage, all cleat joints should be sealed with an approved duct sealer. This applies to all accessory connections as well as the basic Fan Powered Low Profile Terminal Unit. 4. Holes that are drilled in the duct for testing or balancing purposes are to be sealed with duct tape or duct sealer. 4 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

Maintenance Fan and Motor 1. Disconnect all incoming power before servicing the unit. 2. Price Fan Powered Low Profile Terminal Units are supplied with permanently lubricated motors. 3. The blower and motor should be inspected annually for accumulation of dust and dirt. Clean as necessary. 4. To access blower and motor for servicing, remove the side access panel. CAUTION: Motor may be very hot. Ensure motor has cooled before service. 5. Motors are provided with thermal overload protection. If the motor overheats and trips the thermal overload, it will automatically reset after cooling down to a proper operating temperature. 6. If field amperage draw readings of the fan motor are required, measurements should be taken with a true RMS meter. Non-true RMS meters will not provide accurate readings due to alteration of the sine wave by the fan speed controller. Filter(s) 1. Filters, if supplied, should be replaced or removed after system start-up. 2. If filters are used beyond system start-up, they should be changed regularly to avoid excessive restriction of airflow. Frequency would depend on environment. 3. Contact your Price representatives for details on replacement filter media. Air Balancing Procedure Before Air Balancing the terminal unit, the following general items should be verified. 1. The primary fan system is operating at the specified volume, static pressure, RPM and current. 2. Return filters (if supplied) are clean. 3. All balancing dampers are adjusted and locked. Dampers downstream of the terminal unit should be proportionally balanced. 4. Thermostats are calibrated and operational. 5. All ductwork and connections are free from leaks. 6. Sufficient duct static pressure is available at the terminal primary air inlet. 7. All diffusers are installed and adjusted for the proper air pattern. 8. For motors a minimum of 0.1 in. w.g. downstream static pressure is required to prevent overheating of the fan motor. For units with electric heaters a minimum of 0.2 in. w.g. is required. 9. The primary air volume (both minimum and maximum setpoints) is factory calibrated for pneumatic or electric controls supplied by Price. If field adjustment should be necessary, follow the appropriate calibration procedures for the controller type supplied with the unit. If DDC controls are supplied, refer to the control contractor s documentation for calibration instructions. 10. Set the thermostat to full cooling. The fan should be on and the primary air valve at maximum airflow. Verify the airflow with the sensor taps or pitot tube traverse. Adjust if necessary. 11. Set the thermostat to full heating. The fan should be on and the primary air valve at minimum flow. Verify the primary air volume with sensor taps or pitot tube traverse. Adjust if necessary. 12. The fan volume must be field adjusted with the fan speed controller. Adjust the speed control until the desired airflow is measured at the outlets. Note that, if the primary air valve has a minimum setting, the outlet volume will be the summation of fan and primary airflow. priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 5

ECM Motor Adjustment 1. Remove the electrical control cover and connect the leads from a DC Voltmeter to the terminals indicated. 2. Refer to the Test Point Chart for the relevant size unit being adjusted. 3. Determine the test point voltage from the chart or formula based on the desired airflow. 4. Adjust the manual speed control dial on the outside of the box with a screwdriver until the test point voltage is achieved. 5. Wait a few seconds for the ECM motor to adjust its speed and then verify fan flow measurements at the supply outlets. 6. If necessary, fine-tune the speed control in accordance with the measured outlet flow Operating Guidelines 1. Minimum downstream duct static pressure of 0.10 in. w.g. must be maintained to prevent overheating of the fan motor. Overheating of the fan motor can cause the unit to trip the thermal overload and reduce motor life. 2. If electric duct heaters are supplied, 70-cfm/kW minimum airflow across the heater must be maintained. 3. If electric duct heaters are supplied, the discharge air temperature must not exceed 120 F (49 C). ECM MOTOR ADJUSTMENT 24 VAC POWER SUPPLY SPEED CONTROL NEUTRAL SIGNAL 24 VAC COMMON MANUAL SPEED CONTROL DIAL WIRING HARNESS DC VOLTMETER 6 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

Fan Performance Curves - FEVLP, FPVLP, FDVLP - Standard Motor NOTE: Data obtained in accordance with ARI Standard 880-98. Caution to Contractors Fan Powered Terminal Units are not intended for use as temporary heat or ventilation during building construction. The terminal units are not designed nor equipped to operate in a dusty construction environment. Recirculating fan wheels can become coated with construction dust, resulting in an unbalanced wheel. This in turn can contribute to reduced motor life. Inlet air filters would provide little protection as they would quickly become plugged with construction dust. A Fan Powered Terminal Unit should never be operated if the downstream ductwork has not been installed. A minimum of 0.1 in. w.g. downstream static pressure resistance is required for safe operation of the fan motor. For units with electric heaters a minimum of 0.2 in. w.g. is required. NOTE: Price cannot warrant against unauthorized operation under conditions as outlined on this page. UNIT SIZE 20 UNIT SIZE 30 Standard Motor Data Unit Motor 115/1/60 V/Ø/Hz Full Load Amps 208/1/60 V/Ø/Hz 240/1/60 V/Ø/Hz 277/1/60 V/Ø/Hz 20 1 8 2.4 1.1 1.1 1.1 30 1/4 5.2 1.8 1.7 1.6 40 1/2 8.0 3.1 3.1 3.1 UNIT SIZE 40 ECM Motor Data Unit Motor 115/1/60 V/Ø/Hz Full Load Amps 240/1/60 V/Ø/Hz 277/1/60 V/Ø/Hz 20 1/2 2.9 1.4 1.2 30 1/2 5.6 2.8 2.5 40 1/2 6.0 2.9 2.9 NOTE: FLA at 0.2 in. w.g. (50 Pa) External Static Pressure priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 7

Fan Performance Curves - FEVLP, FPVLP, FDVLP - ECM Motor * NOTE: Unit size 20 can not be programmed for factory set fan flow. The fan air volume will vary as the external static pressure varies in accordance with the fan curves illustrated. All other features and benefits of the ECM motor apply to the size 20 unit. UNIT SIZE 20 - NO COIL, 1 AND 2 ROW COIL* Caution to Contractors Fan Powered Terminal Units are not intended for use as temporary heat or ventilation during building construction. The terminal units are not designed nor equipped to operate in a dusty construction environment. Recirculating fan wheels can become coated with construction dust, resulting in an unbalanced wheel. This in turn can contribute to reduced motor life. Inlet air filters would provide little protection as they would quickly become plugged with construction dust. A Fan Powered Terminal Unit should never be operated if the downstream ductwork has not been installed. A minimum of 0.1 in. w.g. downstream static pressure resistance is required for safe operation of the fan motor. For units with electric heaters a minimum of 0.2 in. w.g. is required. NOTE: Price cannot warrant against unauthorized operation under conditions as outlined on this page. 8 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

UNIT SIZE 30 - NO COIL UNIT SIZE 40 - NO COIL UNIT SIZE 30-1 ROW COIL UNIT SIZE 40-1 ROW COIL UNIT SIZE 30-2 ROW COIL UNIT SIZE 40-2 ROW COIL priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 9

Electronic Airflow Adjustment Procedure In order to correct for poor inlet conditions (which cause inaccurate airflow sensing) or changing design parameters, it may be necessary to adjust the factory set minimum and maximum airflow rates of a Fan Powered Low Profile Terminal Unit in the field. These adjustments are performed at the wallmounted thermostat. In the event that inlet conditions to the terminal are causing the inaccuracies, the calibration curves referred to in the procedures will no longer be valid. In this case, either a duct traverse or air outlet measurement will be required to establish true air volumes. Calibration Procedure for Velocity Adjustments made at Thermostat A. Required Tools: 1. Small flat blade ( 1 8 in.) screwdriver. 2. Digital Voltmeter capable of displaying a 0 to 10 VDC range which will display in.01 VDC increments. 3. Test Leads (#HSO-5001). 6. Read the DC voltage across the meter taps on the cooling (right) side. Adjust the maximum setpoint (MAX INCR) Potentiometer (4) (clockwise to increase or counter-clockwise to decrease) to the DC voltage equal to the desired flow (CFM). The DC voltage may be determined from the calibration curves or by direct air flow measurement. NOTE: The maximum setpoint must be adjusted last. Adjustment of the MIN INCR Potentiometer directly affects the maximum setpoint. 7. Return the cooling setpoint slider to the desired setpoint. Insert setpoint slider stops if required. Replace the thermostat cover. FIGURE 1 CTE - 5101 (3) (4) B. Remove Thermostat Cover Thermostat Cover is removed by releasing the mounting screws on either side of the cover. C. CTE-5101 Cooling Thermostat 1. Be certain the ambient room temperature at the thermostat is within the range of the thermostat (55 F to 85 F) (13 C to 29 C). 2. Connect Digital Voltmeter to the meter taps (1) (Figure 1)on the face of the room thermostat using test leads (Figure 2). 3. Adjust the cooling setpoint slider (2) all the way to the right for minimum cooling. 4. Read the DC voltage across the meter taps on the cooling (right) side. Adjust the minimum setpoint (MIN INCR) Potentiometer (3) (clockwise to increase or counterclockwise to decrease) to the desired DC voltage. The DC voltage may be determined from the calibration curves or by direct air flow measurement. NOTE: The minimum setpoint must be adjusted first. Adjustment of the MIN INCR Potentiometer directly affects the maximum setpoint. 5. Adjust the cooling setpoint slider all the way to the left for maximum cooling. (2) FIGURE 2 TEST LEADS AND METER HOOK-UP TEST LEADS (1) 10 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

Airflow Adjustment Procedure FIGURE 3 CTE-5105 CTE-5105 Day/Night Thermostat Cooling Side of the Thermostat. 1. Adjust MIN/MAX settings using same procedure as CTE-5101 (6) (5) (3) (4) NOTE: The maximum setpoint must be adjusted last. Adjustment of the MIN INCR Potentiometer directly affects the maximum setpoint. (8) Heating Side of the Thermostat. (1) 1. Be certain the ambient room temperature is within the range of the thermostat (55 F to 85 F) (13 C to 29 C). 2. Connect Digital Voltmeter to the metre taps (8) (fig 4) on the face of the room thermostat using Kreuter test leads (PT#HSO-5001) (Figure 2). (7) (2) 3. Adjust the night Set Point Slider (7) all the way to the right for minimum night. 4. Read the DC voltage across the metre taps on the heating (left) side. Adjust the minimum setpoint (MIN INCR) Potentiometer (5) (clockwise to increase or counterclockwise to decrease) to the desired DC voltage. The DC voltage may be determined from the calibration curves or by direct air flow measurement. NOTE: The minimum setpoint must be adjusted first. Adjustment of the MIN INCR Potentiometer directly affects the maximum setpoint. 5. Adjust the night Setpoint Slider all the way to the left for maximum night. 6. Read the DC voltage across the metre taps on the heating (left) side. Adjust the maximum setpoint (MAX/ AUX INCR) Potentiometer (6) (clockwise to increase or counter-clockwise to decrease) to the DC voltage equal to the desired flow (CFM). The DC voltage may be determined from the calibration curves or by direct airflow measurement. NOTE: The maximum setpoint must be adjusted last. Adjustment of the MIN INCR Potentiometer directly affects the maximum setpoint. priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 11

Electronic Calibration Curves Calibration Equations Size Equation 6 VDC = CFM / 54 8 VDC = CFM / 103 10 VDC = CFM / 181 12 VDC = CFM / 259 14 x 8 VDC = CFM / 286 14 x 10 VDC = CFM / 360 12 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

Pneumatic Calibration Procedures CP100 / CP200 General 1. Remove the protective metal cover. 2. Aligned markings on the face and dials of the controller indicate that the factory settings are intact. 3. Remove the caps from the tees in the HI (red) and LO (green) tubes leading from the airflow sensor in the assembly inlet. Connect a differential pressure gauge to the tees. A gauge with a 0 to 1 in. w.g. scale is recommended. 4. Refer to the calibration curve for the size assembly being serviced. Read the differential pressure across the sensor for the required airflow. 5. Alternatively, calculate the differential pressure. CP100 (If Supplied) 1. Adjust the minimum (LO) airflow limit first. 2. Set the thermostat signal to 0 psi, or disconnect the thermostat tube to the controller. 3. Turn the minimum (LO) dial on the controller (center knob) until the gauge reads the required differential pressure. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments (verify the minimum setpoint by cycling the thermostat pressures). 4. Apply 15psi minimum air pressure to the thermostat connection at the controller. 5. Turn the maximum (HI) dial on the controller (outer knob) until the gauge reads the required differential pressure. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments (verify the maximum setpoint by cycling the thermostat pressure). CP200 (If Supplied) 1. Adjust the maximum (HI) airflow limit first. 2. Set the thermostat signal to 0 psi, or disconnect the thermostat tube to the controller. 3. Turn the maximum (HI) dial on the controller (center knob) until the gauge reads the required differential pressure. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments (verify the minimum setpoint by cycling the thermostat pressures). 4. Adjust the minimum (LO) airflow limit. 5. Apply 15 psi minimum air pressure to the thermostat connection at the controller. 6. Turn the minimum (LO) dial on the controller (outer knob) until the gauge reads the required differential pressure. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments (verify the maximum setpoint by cycling the thermostat pressure). priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 13

Pneumatic Calibration Procedures CP101 General 1. Reconnect the thermostat tube to the controller if it has been removed during the calibration procedure. 2. Disconnect the gauge and replace the caps on the tees. 3. Replace the protective cover. CP101 A. Damper Action 1. Damper action is factory set. To reset action, loosen damper selection switch screw and align desired action with the damper position. Retighten screw. 2. Actuator must be repositioned to provide appropriate fail-safe position. B. Reset Start Point 1. Reset start point is factory calibrated to the specified setting on the control assembly label. 2. To field adjust, remove the gauge tap cap at G and attach a 0-30 psi pressure gauge. 3. Adjust the thermostat pressure at T port to the desired start point value with a gradual switch or pressure regulator (start point is lowest span pressure). 4. Adjust reset start knob until the gauge pressure begins to increase slightly (greater than zero but less that 0.3). 5. Replace gauge tap cap. C. Reset Span 1. Reset span is factory calibrated to the specified setting on the control assembly label. 2. To field adjust, remove the gauge tap cap at G and attach a 0-30 psi pressure gauge 3. Adjust the thermostat pressure at T port to above 15 psi. 4. Adjust reset span knob until the gauge pressure is equal to the desired reset span (total span pressure, not end span pressure). 5. Replace gauge tap cap. D. Air Volume Limits 1. Remove the caps from the tees in the HI (red) and LO (green) tubes leading from the air flow sensor in the assembly inlet. Connect a differential pressure gauge to the tees. A gauge with a 0 to1 in. w.g. scale is recommended. 2. Refer to the calibration curve for the size assembly being serviced. From the curve, read the differential pressure across the sensor for the required airflow. 3. Alternatively, calculate the differential pressure. 14 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

Direct Acting Cooling or Reverse Acting Heating 1. Adjust the minimum airflow limit first. 2. Set the thermostat signal to 0 psi or disconnect the thermostat tube from the controller. 3. Adjust the LO STAT dial on the controller (center knob) until the gauge reads the required differential pressure for minimum air volume. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments. 4. Adjust the maximum airflow limit, after verifying the minimum airflow limit is set correctly. 5. Apply 15psi minimum air pressure to the thermostat connection at the controller. 6. Adjust the HI STAT dial on the controller (outer knob) until the gauge reads the required differential pressure for maximum air volume. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments. 7. Cycle the thermostat several times. This can be quickly accomplished by removing the cap from the gauge tap (Port G) and varying the bleed rate with finger pressure. Replace the cap and check the airflow limits. If setpoints have changed, repeat steps 1 to 7. Reverse Acting Cooling or Direct Acting Heating 1. Adjust the maximum airflow limit first. 2. Set the thermostat signal to 0 psi or disconnect the thermostat tube from the controller. 3. Adjust the LO STAT dial on the controller (center knob) until the gauge reads the required differential pressure for maximum air volume. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments. 4. Adjust the minimum airflow limit, after verifying the maximum airflow limit is set correctly. 5. Apply 15-psi minimum air pressure to the thermostat connection at the controller. 6. Adjust the HI STAT dial on the controller (outer knob) until the gauge reads the required differential pressure for minimum air volume. Turn the dial slowly, allowing time for the damper actuator to complete its travel in response to the adjustments. 7. Cycle the thermostat several times. This can be quickly accomplished by removing the cap from the gauge tap (Port G) and varying the bleed rate with finger pressure. Replace the cap and check the airflow limits. If setpoints have changed, repeat steps 1 to 7. General 1. Always adjust the LO STAT dial first. 2. After calibration is complete, reconnect the thermostat tube to the controller if it has been removed during the calibration procedure. 3. Disconnect the gauge and replace the caps on the tees. 4. Replace the protective metal cover. DDC Calibration Procedures Refer to control contractor documentation for details. priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 15

Airflow Sensor Calibration Equation ( ) 2 VP = Q K VP - differential pressure at sensor, in. w.g. Q - air flow rate, cfm at standard density. K - calibration constant Unit Size K 6 468 8 890 10 1487 12 2141 14x8 2084 14x10 2760 1. Gauge taps are normally supplied with the pneumatic controls to allow field measurement of the differential pressure at the sensor with a manometer, magnahelic or other measuring device. If the terminal velocity controls utilize a flow-through transducer, a proper velocity pressure reading will NOT be read at the gauge taps and the calibration curves CANNOT be used for field measurement. The flow-through transducer operates on the principle of mass flow rather than pressure differential. Controls utilizing a dead-ended pressure transducer will allow field measurement with the gauge taps and calibration curves provided. 2. Setting flow limits for a differential pressure of less than 0.02 in. w.g. is NOT recommended. Stability and accuracy of flow limits may not be acceptable due to low velocity pressure signal. Performance will vary depending on the terminal unit controls provided. 3. For field calibration of airflow limits refer to the control contractor s documentation. 16 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

MAINTENANCE Troubleshooting General Noise Primary Air Volume Not as Specified Air Volume Not As Specified Fan Does Not Operate 1. Confirm fan box size and rating with blueprint and box schedule (check Control Assembly label on terminal unit). 2. Visually check pneumatic and electrical connections with the Control Wiring diagram(s) located inside the electrical enclosure or in the applicable controls brochure. 3. Verify that the supply voltage is the same as specified on the control diagram(s) or Voltage Information label. 4. Confirm main air pressure (15 psi min., 25 psi max.) 1. Foreign material in fan. 2. Relay chatter. 3. Fan or duct size selection too small for application causing high air velocity. 4. Vibrating ductwork. 5. Unbalanced fan wheel causing it to hit the housing. 1. Check controller operation adjust if necessary. 2. Check for proper control signal from thermostat. Cycle thermostat and monitor. 3. Confirm sufficient inlet duct static pressure is available at the terminal unit. 4. There should be a minimum of 3 duct diameters of straight inlet duct, either sheet metal or flexible. It is to be the same size as the inlet, between the unit inlet and any transition, take-offs or fittings. Poor inlet conditions may necessitate controller re-calibration. 5. Check the flow sensor for blockage. 1. Check filter for excessive dust build-up. 2. Check fan for particle blockage. 3. Check coils for particle blockage. 4. Measure downstream static pressure, it must be no less than 0.10 in. w.g. order to keep the fan from overheating (0.2 in. w.g. for units with electric heat). 5. Verify that the supply voltage is the same as specified on the wiring diagram. See wiring diagram pasted on the inside of the electrical enclosure or in the applicable controls brochure. 6. Insulating duct liner loose. 7. Unit was not air balanced. 8. Leaks in ductwork. 9. Obstruction in ductwork. 10. Sharp elbows near fan outlet. 11. Improperly designed turning vanes. 1. Check the unit against the provided Control and Wiring diagrams. See inside cover of the electrical enclosure for diagrams. 2. Verify that the disconnect switch or breaker is not opened. 3. Check for proper control signal from thermostat. See thermostat for full heating and monitor output. 4. If fan cycles on and off, check the downstream static pressure. It must be no less than 0.10 in. w.g. in order to keep the fan from overheating (0.2 in. w.g. for units with electric heat). 5. Fan wheel may be touching the housing. priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 17

MAINTENANCE Replacement Parts Component Part# Description Fan Motors (Totally Open) EON Fan Motors Fan Speed Controllers Capacitors Blowers Controllers Actuators Thermostats Control Components 019588-001 208/240V 1/8 HP (Size 20) 019589-002 208/240V 1/4 HP (Sizes 30-50) 019589-003 208/240V 1/2 HP (Size 40) 019150-001 115V 1/8 HP (Size 20) 019152-002 115V 1/4 HP (Sizes 30-50) 019154-003 115V 1/2 HP (Size 40) 019151-001 277V 1/8 HP (Size 20) 019153-002 277V 1/4 HP (Size 30) 019155-003 277V 1/2 HP (Size 40) 019178-007 120V/240V 1/2HP (Sizes 20, 30, 40) 019179-007 277V 1/2 HP (Sizes 20, 30, 40) 233563-100 8A / 115V (Sizes 20-40) 233563-200 8A\277/240/208V (Sizes 20-40) 019874-001 5 mfd (Size 20, 30) 019874-006 7.5 mfd (Size 30) 019874-002 10 mfd (Sizes 30-40) 019874-007 20 mfd (Size 40) 100185-001 Size 20 100185-002 Size 30 100185-003 Size 40 019815-001 Electronic CSP-5001 Controller/Actuator 076730-002 Pneumatic CP100 Controller 076824-001 Pneumatic CP200 Controller 076823-001 Pneumatic CP101 Controller 019915-001 Electric MEP-5001 24V Floating 019096-001 Electric ML6161B 24V Floating 076857-001 Pneumatic MCP-8031 Actuator 076863-001 Electronic Cooling (CTE-5101) 019723-001 Electronic Heating-Cooling (CTE-5103) 019726-000 Electronic Cooling w/reheat (CTE-5104) 076813-001 Pressure Diverting Relay 076811-001 LO Pressure Selector 076817-001 HI Pressure Selector 019873-001 P-E Switch 019436-004 115/24V 20A Transformer 019436-001 115/24V 50A Transformer 019436-005 277/24V 50A Transformer 18 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

NOTES priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 19

NOTES 20 Fan Powered Low Profile Variable Volume Terminal Units - Manual priceindustries.com

NOTES priceindustries.com Fan Powered Low Profile Variable Volume Terminal Units - Manual 21

This document contains the most current product information as of this printing. For the most up-to-date product information, please go to priceindustries.com 2014 Price Industries Limited. All rights reserved.