MD2U Series 2-Phase Unipolar Stepper Motor Driver

Similar documents
Compact And High-Performance Of 2-Phase Stepper Motor Driver. RUN current

0.6A, 1.5A, 2.25A, 3A/Phase

35 35A 50 50A 1 Single phase. Solid state power controller

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Please read Safety Considerations in operation manual before using. [Ai-M-42 Series] [Ai-M-56 Series] [Ai-M-60 Series] 67.5mm mm. 73.

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

AK-G/AK-GB/AK-R/AK-RB Series

5-Phase Stepper Motor

Operating Manual For Stepper Driver

User s Manual. For DM542T. Full Digital Stepper Drive

User s Manual. For DM860T. Fully Digital Stepper Drive. Version 1.0 Designed by StepperOnline All Rights Reserved

ClosedLoop Stepper Motor System Specifications Model AiSD4SA AiSD4MA AiSD4LA AiSD6SA AiSD6MA AiSD6LA Power supply 4VDC Allowable voltage range 9 to %

5-Phase Stepper motor

KL-8070D. Fully Digital Stepping Driver. Table of Contents 1. Introduction, Features and Applications...1 Introduction...1 Features...

MondoStep 7.8. High Performance Microstepping Driver. User s Manual. Version PROBOTIX All Rights Reserved

User's Manual. For M542T. High Performance Microstepping Driver. Version All Rights Reserved

5-Phase Stepper Motor

User s Manual. For M542. High Performance Microstepping Driver. Version All Rights Reserved

User Manual of 2MA2282

User s Manual-M752. Stepper Motor Driver. Version All Rights Reserved. Attention: Please read this manual carefully before using the driver!

Manual of SM442. High Performance Microstepping Driver. Nietz Electric Co.,Ltd.

Technical Description

DP-153/DP-153-L Stepper Drive

STEPPING SYSTEMS. Stepping Systems ENGLISH

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

1 Form A 5A small size power relay for interface

DP-304/DP-304-L Stepper Drive

Analog Output Terminal

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Analog Input Terminal

User Manual. Model P403. High Performance Microstepping Driver

Names and Functions of Driver Parts

User s Manual. For. BH-MSD-4.5A Micro Stepping Driver

Compact Linear Actuators

DP-504/DP-508 Stepper Driver

Brushless Motors. Brushless Motors/AC Speed Control Motors. Brushless Motors/AC Speed Control Motors D-11. AC Input BX Series. AC Input BLF Series

DP-504/DP-508 Stepper Driver

User s Manual. For. BH-MSD-2A Micro Stepping Driver

Cylindrical type proximity sensor

R A, 80V Microstepping Driver The PowerHouse

PKG-341-MBC08-PS-CBL System Diagram and Specifications

Digital display Pressure range ON/OFF output Linear output Model

BX Series D-62. Brushless Motor and Driver Package. Features Speed Control. Position Control D-62

Model Number Structure

The smart actuator is a complete drive system with electronic, able to detect position and / or can be interfaced via a communication bus.

DRL Series. RoHS-Compliant Compact Linear Actuators. Features

Stepper Motors ver ver.5

Three Phase Power Controller THW-A Series

Technical Information Solid State Relays. Glossary. Solid State Relays

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

Surface mounting, flush mounting, and DIN track mounting

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Brushless Motor and Driver Packages. BX Series. Capable of Speed Control, Position Control and Torque Limiting World-Class Brushless Motors

Hollow Rotor. Large Bore Bearing. Hollow Rotor

Completely free from the Concern of Loss of Position (Alarm Feneration when Step-Out) Perfect Positiooning and Completion (Positioning Completion

NX Series. Tuning-Free AC Servo Motor Unit

Instruction Manual. Selectable Microstep 2-ph Stepping Motor Driver RD-026MSA RORZE CORPORATION

FE100/FE200. AC Speed Control Motors. Features

CVK Series. 1.8, 0.72 and 0.36 Stepper Motor and Driver Package. DC Input

RHINO MOTION CONTROLS

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

DRV-1. Step Motor Drive. User Manual Mentor Avenue Cincinnati, Ohio Tel (513)

M545D. Stepper Motor Driver Specification. Overview. Applications

RoHS-Compliant. Brushless DC Motor and Driver Package BX Series

SR8-Plus 2 Phase Step Motor Drive

DM320C. User s Manual. Fully Digital Stepping Driver. For. Version All Rights Reserved

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

SA1W: Water Detection Sensors

MD24 / MD28 Microstepping Driver odul

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

3-colour / 2-screen display

Brushless Motors. BMU Series. Connector Type NEW. Easy speed control, easier to use. New connector type with smart wiring.

J1000. Compact Inverter Series.

MSD Phase Step Motor Drive User Manual

Brushless Motor and Driver Packages BX Series. Capable of Speed Control, Position Control and Torque Limiting World-Class Brushless Motors

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Motorized Cylinders. EZC Series. Stroke 150 mm

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

THV-40SERIES. Power Controller. Single Phase Thyristor Unit (High Voltage Type) AC V. RoHS compliant

Hybrid Control System, Alpha Step

DC Input. Brushless Motors/AC Speed Control Motors D-89. Brushless Motors/AC Speed Control Motors D-89. BLH Series. Overview, Product Series

CRK Series /0.72 Stepping Motor and Driver Package. Features

ABL Series. Relay Terminal Block (Screwless Type) Features

Model Number Structure

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Instruction Manual. Selectable Microstep 2-ph Stepping Motor Driver RD-021M8 RORZE CORPORATION

Table 1: 2-pin Terminal Block J1 Functional description of BSD-02LH Module Pin # Pin Description Table 2: 10-pin Header J2 Pin # Pin Description

User s Manual. Table of Contents. Low Cost Microstepping Driver 9. Connection Diagram for Driver, Motor, Controller 12

Identifying the Motorized RGS part number codes when ordering

SMD10 SMD11 SMD15 SMD30

Instruction Manual. Selectable Microstep 5-ph Stepping Motor Driver RD-053MS RORZE CORPORATION

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

DC Input. Brushless Motors/AC Speed Control Motors D-117. Brushless Motors/AC Speed Control Motors D-117. BLH Series. Overview, Product Series

Transcription:

MDU Series -Phase Unipolar Stepper Motor Driver Compact nd High-Performance Of -Phase Stepper Motor Driver Features Unipolar constant current drive type Enable to brake when it stops by STOP current adjustment Low speed and precise control with microstep (MDU-MD0) Insulate using photocoupler to minimize the influence by external noise Power supply: -VDC Please read Caution for your safety in operation manual before using. Ordering Information MD U M D 0 Specifications MDU-MD0 0 /Phase MDU-ID0 Model MDU-MD0 MDU-ID0 Power supply 1 -VDC llowable voltage range 80 to 10% of the rated voltage RUN current 0. to / Phase Drive method Unipolar constant current drive type Current consumption Max. Resolution 1,,,, 8, 10, 1, 0 division - Input pulse width Min. 10μs - Pulse duty Max. 0% - Input pulse Rising/falling time Max. 0.μs - spec. Pulse input voltage [H] -8VDC, [L] 0-0.VDC - Max. input pulse frequency Max. 0kHz - Input resistance 00Ω (, ), 90Ω (HOLD OFF).kΩ (/, RUN/STOP, HOLD OFF) Insulation resistance Min. 00MΩ (based on 00VDC of electrification and non-electrification parts) Dielectric strength 1000VC 0Hz for 1 minute (between electrification and non-electrification parts) Noise resistance ±00V the square wave noise (pulse width: 1μs ) by the noise simulator Vibration 1.mm amplitude or 00m/s at frequency of 10 to Hz (for 1 min.) in each X, Y, Z direction for hours Shock Vibration 00m/s² (approx. 0G) in each X, Y, Z direction for times Environment mbient temperature 0 to 0, storage: -0 to 0 mbient humidity to 8%RH, storage: to 8%RH pproval Weight pprox. 9g (approx. 180g) pprox. 0g (approx. 190g) 1: When using over 0VDC, it should be mounted at a well-ventilated place due to increasing heat. : The max. value of RUN current is based on RMS value in accordance with frequency of running motor, peak power can be changed by load fluctuation. : mbient temperature is and ambient humidity is %RH. : It can be changed by pull-out frequency and max. slewing frequency range. : The weight includes packaging. The weight in parentheses is for unit only. Environment resistance is rated at no freezing or condensation. D M I U -VDC Micro Step Intelligent type Unipolar drive -Phase MD Motor Driver () Photoelectric (B) Fiber Optic (C) Door/rea (D) Proximity (E) Pressure (F) Rotary Encoders (G) Connectors/ Sockets (H) Temperature (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software Q-7

MDU Series -Phase Micro Stepper Driver [MDU-MD0] Unit Descriptions Power indicator LED Function selection switch Microstep, pulse input mode setting No. Name Function Switch position ON OFF Function selection switch RUN current adjuster Input Motor terminal connection terminal STOP current adjuster Power terminal 1 MS1 MS MS Microstep setting MS1 MS MS Resolution ON ON ON 1 (Full-step) ON ON OFF -division ON OFF ON -division ON OFF OFF -division OFF ON ON 8-division OFF ON OFF 10-division OFF OFF ON 1-division OFF OFF OFF 0-division 1P/P Pulse input mode 1 Pulse method Pulse method Resolution setting (MS1/ MS/ MS) switch to select micro step angle to drive a motor. Micro stepper is to make basic step angle of -phase motors (1.8 ) divided into smaller angle according to setting values. The formula for microstep angle is; 1.8 Rotation angle per pulse of -phase[ ] = Resolution It may cause step-out if resolution is changed while motor is running. 1P/P switch to select pulse input type 1-pulse input mode : Operation command pulse input, : Rotation direction pulse input ([H]:, [L]: ) -pulse input mode : direction rotation pulse input, : direction rotation pulse input RUN current setting RUN CURRENT 0. CT.0 CT RUN current is a phase current provided to -phase stepper motor. Be sure to set RUN current at the rated current or below. If not, it may cause heat generation, loss of torque or step-out. RUN current setting range: 0. to.0 RUN current setting: Measure the voltage by connecting a DC voltage meter to both CT+ and CTterminals while the motor is running (Max. 10rpm) E.g.) Input Voltage (V) / = (Motor's excitation current) djust the RUN current in case severe heat generation occurs. Be sure that torque decreasing may occur when adjusting the current. Note) Be sure to adjust RUN current while motor is running. Q-8

-Phase Unipolar Stepper Motor Driver STOP current setting STOP CURRENT 0% 70% Stop current is a phase current provided to -phase stepper motor at standstill. function to reduce the current in order to suppress the heat generation at motor standstill / Use variable resistance ratio within 0 to 100% of RUN current to set STOP current (ctual setting range is 0 to 70% of RUN current). E.g.) If RUN current setting value is and STOP current setting value is 0%, STOP current will be set to 0.. STOP current setting value may have some deviation depending on resistance impedance of motor. uto current down function will be activated when HOLD OFF signal is [L]. When HOLD OFF signal is [H], the function is not activated since the current provided to each phase is cut off. Note)Be sure to adjust STOP current while motor is at standstill. HOLD OFF function When HOLD OFF input signal is [H], motor excitation is released. When HOLD OFF input signal is [L], motor excitation is in a normal status. function used to rotate motor's axis using external force or used for manual positioning. HOLD OFF Input signal [H] and [L] represent photocoupler ON/OFF in a circuit. Please do not use for stopping motor. Input Output Diagram nd Connections () Photoelectric (B) Fiber Optic (C) Door/rea (D) Proximity (E) Pressure (F) Rotary Encoders (G) Connectors/ Sockets (H) Temperature 00Ω 00Ω 90Ω 1 1 -com B-com HOLD OFF +VDC Motor -pulse input mode - direction rotation pulse input 1-pulse input mode - Operation command pulse input -pulse input mode - direction rotation pulse input 1-pulse input mode - Rotation direction pulse input [H]:, [L]: HOLD OFF Motor excitation OFF control signal [H]: Motor excitation OFF (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & B (R) Graphic/ Logic Panels B (S) Field Network Devices DC+ DC- + -VDC - (T) Software Note) dd external resistance when power for pulse from the external of the unit exceeds +V. (Input power: Max. VDC, Input current: 10 to 0m) Q-9

MDU Series Time Chart 1 Pulse input Pulse input [H] [L] [H] [L] [H] [L] [H] [L] Rotation position Rotation position Dimensions (unit: mm).. 100 9 100 10 0 9. 7 7. 8 Q-0

-Phase Unipolar Intelligent Stepper Motor Driver -Phase Intelligent Stepper Motor Driver [MDU-ID0] Unit Descriptions STRT speed adjuster RUN speed adjuster Power indicator LED CC time setting adjuster DEC time setting adjuster () Photoelectric (B) Fiber Optic (C) Door/rea (D) Proximity (E) Pressure Function selection switch RUN current adjuster Input Motor terminal connection terminal STOP current adjuster Power terminal Intelligent type stepper motor driver? MDU-ID0 is an intelligent type stepper motor driver including all features to control -phase stepper motors so that no controllers are required. Realizing C motor's driving features to stepper motors Controlling STRT speed, RUN speed and CC/DEC speed User-friendly design to realize various functions (front switch and volume) Function selection switch ON 1 S/W No. 1 Max. speed Name SYM/NORML MS MS H/L SPEED (rpm) Switch ON: Symmetry OFF:symmetry (Normal) ON ON 100 ON OFF 10 ON: High speed OFF ON 1000 OFF OFF 00 D 1 D 1 D 1 OFF: Low speed 10 1: D=Don't care Reset the power after changing function selection switch operations. Selection of Symmetry/symmetry function to make the CC/DEC time of run-speed as asymmetry or symmetry using DIP switch No. 1. (F) Rotary Encoders (G) Connectors/ Sockets (H) Temperature (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units Speed (rpm) symmetry (Normal) of ac.deceleration=sym_off (O) Sensor Speed (rpm) D D CC time and DEC time are repeated as a asymmetrical figure Symmetry of ac.deceleration=sym_on Time (sec) D D Time (sec) CC time and DEC time are repeated symmetrical figure It is able to set the gradient (acceleration and deceleration time) as CC/DEC time. Selection of max. speed (MS, MS) function to select the max. speed of motors. The max. speed of stepper motor is changed by MS/MS and Hi/Low speed. The features of run and vibration are able to change depending on MS, MS. Lower the max. speed to run a motor smoothly. Selection of H/L SPEED H/L SPEED mode selection switch: c.deceleration control is not available in Low speed mode since all sections are included in Pull-in range. Low speed mode: It is able to drive a motor up to 10rpm of max. drive speed. High speed mode: It is able to drive a motor up to 100rpm of max. drive speed. (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software Q-1

MDU Series Q- RUN current setting RUN CURRENT 0. CT.0 CT STOP current setting STOP CURRENT 0% 70% RUN current is a phase current provided to -phase stepper motor. Be sure to set RUN current at the rated current or below. If not, it may cause heat generation, loss of torque or step-out. RUN current setting range: 0. to.0 RUN current setting: Measure the voltage by connecting a DC voltage meter to both CT+ and CTterminals while the motor is running (Max. 10rpm). E.g.) Input Voltage (V) / = (Motor's excitation current) djust the RUN current in case severe heat generation occurs. Be sure that torque decreasing may occur when adjusting the current. Note) Be sure to adjust RUN current while motor is running. Stop current is a phase current provided to -phase stepper motor at standstill. function to reduce the current in order to suppress the heat generation at motor standstill / Use variable resistance ratio within 0 to 100% of RUN current to set STOP current (ctual setting range is 0 to 70% of RUN current). E.g.) If RUN current setting value is and STOP current setting value is 0% (ctual setting value is 0%), STOP current will be set to 0.. STOP current setting value may have some deviation depending on resistance impedance of motor. uto current down function will be activated when HOLD OFF signal is [L]. When HOLD OFF signal is [H], the function is not activated since the current provided to each phase is cut off. Note) Be sure to adjust STOP current while motor is at standstill. RUN speed setting RUN SPEED It sets max. RUN speed. Max. RUN speed can be different depending on max. speed setting (MS, MS) and driving mode 0% 100% setting (Hi/Low speed). Consider motor type and its RUN current when setting max. RUN speed. Missing step could occur due to max. input pulse frequency of motors. Set the value when the motor stops. STRT speed setting STRT SPEED It sets desired STRT speed. Max. STRT speed value is same with RUN speed value. STRT speed must be set within max. starting frequency. It is recommended to set up STRT speed within 0 to 0% for stable driving. Set the value when the motor stops. 0% 100% CC time setting CC TIME It sets the acceleration time from STRT speed to max. driving speed. T_1 operation mode when CC time is under.%, T_ operation mode when CC time is under 0% 100%.% and T_ operation mode when CC time is over.%. T_1 is 0. sec. when RUN speed=100%, STRT speed=0%. T_ is 1 sec. when RUN speed=100%, STRT speed=0%. T_ is sec. when RUN speed=100%, STRT speed=0%. Set the value when the motor stops. DEC time setting DEC TIME It sets the deceleration time from max. RUN speed to STOP. 0% 100% DT_1 operation mode when DEC time is under.%, DT_ operation mode when DEC time is under.% and DT_ operation mode when DEC time is over.%. DT_1 is 0. sec. when RUN speed=100%, STRT speed=0%. DT_ is 1 sec. when RUN speed=100%, STRT speed=0%. DT_ is sec. when RUN speed=100%, STRT speed=0%. Set the value when the motor stops. CC Time and DEC Time are declined in proportion to the setting value of STRT speed. The figures above indicate the factory default for each value. HOLD OFF function When HOLD OFF input signal is [H], motor excitation is released. When HOLD OFF input signal is [L], motor excitation is in a normal status. function used to rotate motor's axis using external force or used for manual positioning. HOLD OFF input signal [H] and [L] represent Photocoupler ON/OFF in a circuit. Please do not use for stopping motor.

-Phase Unipolar Intelligent Stepper Motor Driver Time Chart High speed mode RUN/STOP ON OFF / ON OFF Rotation speed and direction (Symmetry mode) CC time DEC time Motor Stop CC time (Same as DEC time) () Photoelectric (B) Fiber Optic (C) Door/rea (D) Proximity (E) Pressure It accelerates up to RUN speed during CC time after RUN signal is ON and decelerates during DEC time after it is OFF. It is disable to change the direction during the signal is ON and it takes 0.sec. for deceleration when DEC time is "0%". Low speed mode Max. RUN speed is 10rpm and CC and DEC time are not available. It is same with High speed to change RUN/STOP and direction. Input Output Diagram nd Connections Inner power (-VDC) RUN speed. kω. kω. kω VDC (Inner) Power 1 1 DC+ DC- RUN/STOP / HOLD OFF COM Inner adjuster control -com B-com B B Note) External adjuster control kω (1 to kω ) - + -VDC - 0-VDC + Note) External voltage control Motor RUN/STOP signal input [ON]: RUN, [OFF]: STOP Direction signal input [ON]:, [OFF]: HOLD OFF signal iuput [ON]: HOLD OFF, [OFF]: HOLD ON Inner adjuster control (djusting RUN speed with front VR) Make the connection between terminal No. and No.. COM RUN speed VDC (Inner) External adjuster control (djusting RUN speed with connecting external variable resistance) Connect variable resistance kω (1 to kω ) for external adjuster control. If variable resistance is too low, full range setting might not be possible. Make sure to adjust RUN speed VR to maximum for external adjuster control. COM External adjuster RUN speed VDC (Inner) kω (1 to kω ) 1 External voltage control (djusting RUN speed with external voltage input) Make sure to adjust RUN speed VR to maximum external voltage control. (F) Rotary Encoders (G) Connectors/ Sockets (H) Temperature (I) SSRs / Power (J) Counters (K) Timers (L) Panel (M) Tacho / Speed / Pulse (N) Display Units (O) Sensor (P) Switching Mode Power Supplies (Q) Stepper Motors & Drivers & (R) Graphic/ Logic Panels (S) Field Network Devices (T) Software Note) Inner adjuster is correlated to external adjuster control and external voltage control. Make sure that inner adjuster must be set to maximum in order to set maximum RUN speed using external adjuster and external voltage. RUN speed COM - + External voltage 0-VDC Q-

MDU Series Dimensions.. (unit: mm) 100 9 100 10 0 9. 7 7. 8 Proper Usage Failure diagnosis and management Check the connection of controller and driver, if motor does not rotate. Check the DIR input of driver, if motor rotates as a reverse direction, it is for [ON] and for [OFF]. If motor does not work properly, Check the connection of driver and motor. Check driver output current and RUN current of motor depending on current adjuster are correct. Caution during use Caution for signal input When using the pulse input method, do not input and at the same time, or it may cause malfunction. (MDU-MD0) Direction cannot be changed during the operation. (MDU-ID0) In case, the signal input supply is higher than rated supply expressed on the specification, please connect the additional resistance to external part. Caution for setting the RUN and STOP current Run current must be set under a rated current of the motor because motor emits heat too much when a RUN current is set over a rated current of the motor. Caution for wiring Use twisted pair (Over 0.mm ) for the signal wire should be shorter than m. Please use an electric wire thicker than the motor lead wire when lengthening the motor wire connection. Please leave a space over 10cm between a signal wire connection and power wire. Caution for installation Keep the heat sink as close as possible to metal panels and place the unit in well-ventilated area in order to increase heat protection efficiency of heat sink. Heat generation may occur on drivers depending on installation environments. Place the unit with keeping the heat sink under 80. Caution for using function switch When the input switch is changed to P input method during the operation, it may be danger as the motor is rotated reversely. Please do not change the input signal method and resolution during the operation. Motor vibration and noise can occur in specific frequency period. Motor vibration and noise can be lowered by changing motor installation or attaching damper. Use the unit in a range without vibration and noise by RUN speed adjustment or microstep. (MDU-MD0) Use the unit a range without vibration and noise range by RUN speed adjustment. (MDU-ID0) This unit may be used in the following environments. Indoor ltitude: Under,000m Pollution degree Installation category Ⅱ Q-