INSTALLATION / OPERATION / MAINTENANCE GUIDE

Similar documents
INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

INSTALLATION INSTRUCTIONS

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

AMAIRCARE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS. Rules for Safe Installation and Operation

PHOENIX GUARDIAN H. E. P. A. SYSTEM

UNPACKING THE UNIT. Alcohol cleaning pad

TABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.

IMPORTANT: SAFETY INSTRUCTIONS

Cleanshield HEPA 550 Owner s Manual

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

PHOENIX MINI-GUARDIAN

I N ST R UC T I ON MODEL HVH23 STAND-ALONE EXHAUST HOOD MODELS. FORM (May 2000) S. RIDGE AVENUE TROY, OHIO

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

HEPA AIR FILTRATION SYSTEM

Installation and Service Manual

Safety & Installation Instructions

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

INSTALLATION TEMPLATE

Pro Island Ventilation Hoods

HEPA Filtration. HEPA DM 3000P Air Filtration System IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Air Purifiers Product Guide

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

User Manual. Model: FSL300 Dual Port Laser Fume Extractor

Installation Instructions

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

SLIMZONE CLASSIC /

Portable HEPA System

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

Record the serial number and date of purchase in your manual for future reference.

SPH General Manual 400 Series

MODEL FA5 Air Filtration System. Operations Manual

Model G14SD Vapor Management System

OVER THE RANGE MICROWAVE OVEN/HOOD SYSTEM INSTALLATION INSTRUCTIONS

MCI. SynAIRgPURE. Owner s Manual

6-54 HEPA Filter Assembly

INSTALLATION INSTRUCTIONS MODELS S S SHALLOW WELL & CONVERTIBLE JET PUMPS PAGE 3 PAGE 8

Instruction Sheet. Subject: Installations Instructions. Air Compressor Kits. Importan

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

OVER THE RANGE MICROWAVE OVEN INSTALLATION INSTRUCTIONS

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

IFD AIR CLEANER SERVICE MANUAL

ENVIRO UNIT CES SERIES

MIMPEN0410. Installation, operation and maintenance manual DMP-170, DMP-170S, DMP-270, DMP-270S, DMP-350, DMP-350S, DMP-450 & DMP-450S

HPFB. Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES.

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

MC2500. Installation and Operation Manual

Further information: Berriman Associates Model 850P.2 Owners Manual

Rainbow 36 V User s Manual

FlexChem Model 404 Rotating Oven

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Owner s Manual Phoenix GuardianR

Installation Instructions

Installation Instructions

AIR INDUCTION SYSTEM

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

LGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions

EXT DUCTLESS FUME HOOD

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

FA1 Series Air Filtration System. Operations Manual

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Networking: Wall-Mount Cabinets PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK Single-Door Fan and Filter Thermal Packages, UL and NEMA Type 1

UV-AIRE AIR PURIFYING SYSTEM

quatroair.com AIR TECHNOLOGIES INC.

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

CENTRAL VACUUM SYSTEMS

Miracle State Of The Art Air Filtration System!

Safety, Installation and Service Manual Models 1952, 1953 & 1972

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

Electric Vehicle Charging Station

EQUIPMENT PROTECTION

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

21", 33", 45", & 61" Installation & Operation Manual

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Portable Air Purifiers

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

INSTALLATION INSTRUCTIONS

Mania EF1 user manual

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Omniaire 1000V Instruction Manual-8/05

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

OmniAire 600N Operations and Maintenance Manual

SlamPak SLPK-CAN-SPYDER1 SKU#94491& I n s t a l l a t i o n G u i d e for the

LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions

Installing the Switch Chassis

powered by INSTALLATION MANUAL Ford 5.0L F Not legal for sale or use in California on pollution-controlled vehicles.

Transcription:

INSTALLATION / OPERATION / MAINTENANCE GUIDE WHOLE HOUSE HEPA FILTRATION SYSTEMS MODEL HS 3.0

Table of contents About Us Imperial Air Technologies Inc.is the only manufacturer that offers you a complete range of products designed to improve indoor air quality, and that provides a wide selection of accessories to facilitate installation. Our vision To offer a complete range of Imperial products that satisfy environmental concerns. Whether your needs involve ventilation,purification,humidification or filtration, Imperial has the customized solution for you, with its range of quality products backed by the best warranty in the industry. Imperial Peace of Mind Limited WARRANTY All Imperial products are backed by the best limited warranty in the industry, for your peace of mind. You benefit from a 10 year warranty (5 years + 5 years prorated) on our motorized impeller and a 5 year warranty on other components including: unit s casing, motor bracket and collars. 1.Getting Started GENERAL INFORMATION 1.1 Unpacking and inspection 2 1.2 Technical data 3 2.Installation Guide INFORMATION FOR INSTALLERS PAGE 2.1 Planning the installation 4 2.2 Type of installation: Return to Return 4 2.3 Type of installation: Stand-Alone 5 2.4 Installing the unit 6 3.Owner s Operation Guide INFORMATION FOR THE HOMEOWNER PAGE 3.1 General Operating Information 9 4. Maintenance Guide GENERAL MAINTENANCEINFORMATION PAGE PAGE 4.1 Changing filters 10 4.2 Cleaning unit 10 So you can breathe easy. Box Content Includes: 1.1.Unpacking and inspection Whole House HS 3.0 Power cord, 5 FT Plenum seal, 7.5 FT Screws, (16) 8 x 32 x 1/2 Template PAGE 2

1.2. Technical Data WHOLE HOUSE HEPA FILTRATION SYSTEMS Dimensions and Clearance installation Return Air Plenum Installation Front View Side View - Clearance Back View Specifications Model HP500 Filtration Stage 1 Prefilter (100511) Filtration Stage 2 Carbon Filter (100512) Filtration Stage 3 HEPA filter (100510) Weight 28 lbs (12.7 kg) Plenum Mount Port Openings 16 x 3.5 (406mm x89mm) Collar Mount Port Openings 8 (203mm) Round* Installation type Plenum,Wall* or Floor*Mounted Electrical Supply 120 VAC @ 60 Hz Power Consumption 134 W Certification CCSA US Air flow data 220-300 CF.M. * Installation requires kit No.100608 IMPORTANT INFORMATION Imperial Air Technologies, Inc.reserves the right to modify a product, without prior notice, whether in design, color or specifications, in order to offer at all times a quality product that is highly competitive. Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. 17 (432 mm) Return Air Plenum and Stand Alone Installations * With Collar Mount Kit Front View 11.587 (294.5 mm) Stage 1 Stage 2 Stage 3 12 (305 mm) Side View - Clearance 22 (559 mm) 17 (432mm) Side View Stage 1 Stage 2 Stage 3 22 (559 mm) 17 (432 mm) 11.587 (294.5 mm) 12 (305 mm) 13 (330mm) PAGE 3

2. Information for the Installer INSTALLATION GUIDE Special Consideration For integrated system installation Verify clearance on the ductwork to mount the unit using the Forced Air heating/cooling system Minimum clearance requirements for maintenance and service Electrical power requirements Interaction between the HEPA filter unit and other mechanical devices. Ducting Flair System installation The Whole House HEPA Filtration system is designed to install directly onto the return air plenum of the forced air heating/cooling system. Choosing this type of installation eliminates the need to externally duct the HEPA filter unit to the plenum system. If you choose this type of installation, it is recommended that you run the fan on your forced air system continuously to maximize its cleaning ability. TIPS to installer The Whole House HEPA Filtration system does not replace the filter from the forced air heating/cooling system. Regular maintenance of this filter is necessary to permit the good operation of the forced air heating/cooling system. Optional collar system installation Using kit no.100608 the Whole House HEPA Filtration system can be converted to use 8 inch round collars for application requiring ducting.the kit includes two, 8 inch round collars,two mounting brackets for wall or floor mounting, installation guide and fasteners. Return Air Plenum 2.1 Planning the Installation The Whole House HEPA unit is a versatile appliance with multiple installations configuration. It is recommended to take your time in planning the installation. Several Installations are illustrated herein for Whole House filtration applications: Return to return integrated with the forced air heating/cooling system. Central draw points using dedicated duct system Consult the manufacturer for other special applications. 2.2 Type of Installation: Return to Return Integrated System Ducting Flair System (Hepa Mounted on Duct) To living space Return Air Plenum Optional Collar System (Hepa Mounted on Wall) To living space Forced Air Heating/Cooling System Forced Air Heating/Cooling System INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL. Consult your HVAC product manufacturer if the usage of this product will affect the performance of your forced air heating / cooling system. PAGE 4

INSTALLATION GUIDE WHOLE HOUSE HEPA FILTRATION SYSTEMS 2.3 Types of Installation: Stand-Alone Stand Alone Attic Installation Ideal for homes without a forced air heating / cooling system. Allows for air filtration and circulation throughout the home. HEPA system must be operated continuously whenever a part or all the system is located in an unconditioned space to avoid condensation in the ductwork below freezing (0 C, 32 F). Stand Alone Basement Installation Ducting will usually consist of one return with grille from one side of the home, and one supply with grille at the opposite end of the home. PAGE 5

INSTALLATION GUIDE 2.4 Installing the unit Tools required Phillips #2 or Robertson #1 screwdriver 3/32 drill bit Tin snips or metal shear Power Drill Step by step Installation Steps involved in the preparation of the plenum mount system are as followed: Step 1: Preparing return air plenum Find a location that satisfies both service and maintenance requirements and proceed to cut holes as illustrated below. Step 2: Preparing ducting flairs Remove the door and filters and proceed to cut the insulation as illustrated below. Location Return side connections is to be installed after the last branch on the return air plenum and minimum 2 linear ft distance from furnace. A 5-ft power cord is supplied with the unit. If not available a 120VAC outlet needs to be supplied. figure 2.2a - Cut the insulation along the inside edge of both inlet and outlet ports to remove the insulation from the port openings. Note: Refer to Section 4 for details on how to remove the unit s door and filters figure 2.1a - Tape template to return air plenum. Cut opening with metal shears and predrill for the securing screws. figure 2.2b -One cut permits the clean removal of the insulation piece. figure 2.1b - Remove template. figure 2.2c -The unit should look like this when the foam piece is remvouved. PAGE 6

2.4 Installing the unit (Continued) INSTALLATION GUIDE WHOLE HOUSE HEPA FILTRATION SYSTEMS Tips to installer Please consult local authorities to find out whether the installation of electrical products requires the services of a certified technician or electrician. Imperial TIPS to installer Removing the filters from the unit will facilitate your job. Ducting Flairs mounting system The Whole-House Imperial HEPA Plenum Systems are designed for single person installation. Imperial is introducing it s «Ducting Flairs» which is integrated within the unit and will enable you to save time and effort. Once the holes are made in the main return duct and the unit is aligned, the installer just has to unfold the «Ducting Flairs» and screw the unit in place. Step 2:(Continued) Cut the four metal tabs to release the mounting flairs for the inlet and outlet ports. figure 2.2d figure 2.2e Step 2:(Continued) figure 2.2h - Apply plenum seal tape all around both openings on the back of the unit. figure 2.2i figure 2.2f figure 2.2g figure 2.2j- Bend tabs outward approximately 90 degrees. PAGE 7

INSTALLATION GUIDE 2.4 Installing the unit (Continued) Tips to installer It is recommended that the filtration unit have a devoted receptacle with 115V. It is not recommended to connect unit with an extension cord. If no receptacle is available please call an electrical contractor to have one installed. Step 3: Mount Hepa Step 3: (Continued) MAKE SURE TO INSTALL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is located on the unit s motor plate. figure2.3a - Align unit into place. figure 2.3c - Install unit as usual using all supplied fastening hardware. Step 4: Finishing Stage 1: Pre-Filter Stage 2: Carbon filter Stage 3: HEPA Filter figure 2.4a - Remove protective plastic covers from all filters and replace them in their proper location (Stage 1, 2 and 3). figure 2.3b - Unfold the ducting flairs completly to sandwich the return air plenum between the ducting flair and the filtration unit. PAGE 8 figure 2.4b - Replace door and insert power cord into the receptacle of the filter units and the other end into wall outlet.

OWNER S OPEERATION GUIDE 3. General Operating Information WHOLE HOUSE HEPA FILTRATION SYSTEMS Door Switch Mode Selector II I Operations MaximumFiltration figure 2.3c - Installez l'unité comme d' habitude à l'aide des vis fournis. Normal Filtration Function The Whole House HEPA system is comprised of a ventilator, speed selection switch, 3 stages of filtration and the cabinet enclosure system.the ventilator pulls air through the pre-filter and pushes the same air threw the impregnated carbon pad for odor control and finally the last stage of filtration is the HEPA filter which removes 99.97% of particles 0.3µm in size. Operation Mode Options The unit features two speeds of operation for your convenience. The speed selection switch is located on the front of the motor assembly.at lowest speed the unit will provide 220 CFM of clean air while at highest speed, the unit will provide 300 CFM of clean air. It is recommended that the unit be operated on highest speed at all times to maximize the benefits of the HEPA filtration system.if for some reason the filtration needs are not as important then one might operate the unit at low speed. An access door is provided at the front of the unit to permit access to the filters and speed selection switch. Opening the latch on the right side of the unit will permit the door to swing open. A safety door interlock switch cuts the power to the motors for your safety. If needed the door can be removed from the cabinet hinges by holding the top part of the door with one hand and gently taping on the bottom edge of the door with the other hand to release the door from its hinges. Recommended Operation The return plenum mount model operates in conjunction with your forced air heating/cooling system.a forced air distribution system continuously circulates the same air inside your home.the whole house HEPA filtration system operates on the principal of bypass filtration,which means that a portion of the air being returned into the furnace is filtered on each pass. Over time all the air in the home gets cleaned. It is recommended that the furnace blower be in operation whenever the filtration system is in operation. For stand-alone attic installation, the HEPA filtration system must be operated continuously whenever a part of all the system is located in an unconditionned space to avoid condensation in the ductwork below freezing (32 F,0 C) Maintenance of the unit should be performed at regular interval to keep the benefits of the HEPA filtration unit. PAGE 9

4. General Maintenance Information MAINTENANCE GUIDE FMA TM maintenance system In order to improve air quality and offer the best possible air quality in your home, Imperial has developed one of the first maintenance service systems in the industry. The Filter Maintenance Adviser TM will remind you by e-mail when the filter of your Whole House HEPA System must be replaced, to maximize its performance and efficiency. For more information call toll free: 1 888 724-5211 or visit us at: www.imperial.ca When should I Service my Unit? service and accessories Detailed maintenance information is located on the front decal on motor plate. 4.1 Changing Filters After opening the unit s door, grasp both edges of filter and pull with equal force to slide out the filter. 4.2 Cleaning Once a year or as needed, clean the interior of the unit (Wall and motor plates) using mild non-abrasive soap and water. It is recommended to use products that are environmentally friendly. 4.3 Troubleshooting Troubleshooting Suggestions Unit does not operate Is power cord fully inserted in the unit s connector? Is outlet powered? Is door interlock switch operating? PRE-FILTER AND CARBON FILTER Replace filters every 3 to 6 months or as needed. HEPA FILTER Replace filter every 2 to 5 years or as needed. Check regularly to maintain maximum performance from your HVAC system. For replacement filters,contact your local HVAC contractor. Unit operates only on one speed. Unit vibrates 4.4 Electrical Wiring Diagram Possible loose wire inside electrical box, contact your local contractor. Check for excessive dust builup or missing balancing weight on the impeller wheel. INSIDE THE UNIT Once a year or as needed, clean the interior of the unit (Wall and Motor Plate) with a mild and non-abrasive soap. It is recommended to use products that are environmentally friendly. Note to installer IMPORTANT : ALWAYS UNPLUG UNIT BEFORE SERVICING Door Interlock Black Blue M Brown 2.5uf Speed Selection 7.5uf L G N PAGE 10

Protect the natural world from harmful activities of humans Imperial Air Technologies inc. 500 Ferdinand Boulevard Dieppe, NB Canada E1A 6B9 Toll free: 1 888 724-5211 Fax: (506) 388-4633 Visit us at: www.imperial.ca We choose to use recyclable and non-toxic materials when ever possible

Notes