UNIVERSAL Flow Meters

Similar documents
Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

G2 Industrial Grade Meters

KDM ARMORED FLOW METER & SWITCH

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

F-2700 SERIES INSERTION VORTEX FLOW METER

OMP POSITIVE DISPLACEMENT FLOWMETERS

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

F-2700 SERIES INSERTION VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

TELEDYNE HASTINGS INSTRUMENTS

Pressure Instrument Testing Equipment

M Series. Feature rich flow meter and switch with in-line. flow

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

DW PADDLE-BELLOWS FLOWMETER & SWITCH

OMP Positive Displacement Flowmeters

Industrial Meter Catalog

F-2600 SERIES INLINE VORTEX FLOW METER

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

NBK-M - Economical Level Indicator

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

KEL DIFFERENTIAL PRESSURE FLOWMETERS

DPT TARGET TYPE FLOWMETERS

Ar-Mite TM Low Flow Armored Flowmeter

Low Profile Insertion Vortex

King Instrument Company opened its doors in 1983 with one major goal:

INDUSTRIAL METER CATALOG version seven

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Glass Tube Full-View Flowmeters

M3500 Industrial Pressure Transmitter

Adjustable Dead Band Pressure Switches

Glass Tube Flowmeter Model GT1000

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

G2 SERIES INDUSTRIAL GRADE METERS

Adjustable Dead Band Pressure Switches

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

M-200 Series. High flow, Adjustable flow switch with right-angle flow

Valve Position Monitors

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Mid-West. Instrument ELECTRICAL DIVISION 1 LOCATIONS:

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

Masoneilan Series

digital flow meters BW Digi-Meter F-1000

Transmitting Transducer. Gas/Air Velocity Range:

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Smith Meter PD Meters 3" Steel Model E3

KENCO ENGINEERING COMPANY

Quartz. Save Space with Low Profile Design

ISTEC MAGNETIC METERS

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

Rosemount 3051CFA Annubar Flowmeter

Flow-Alert Flow Switches (Micro Switch)

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

O.E.M GAUGES. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Model FVP General Specification. Flanged Vortex Plate. Product Features

SATRON VDt Differential Pressure Transmitter

UniMag DT Series Electromagnetic Flow Tubes

Dual Hi-Lo Pressure Switches

mass flowmeter for compressed air

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

Variable Area Flowmeters Armored Purgemeter

KEL. Heavy Duty Differential Pressure Flowmeters

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

INDUSTRIAL DYNAMICS CO

3" Steel Model E3. We put you first. And keep you ahead.

MINI-NBK ECONOMICAL LEVEL INDICATOR

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Hot Tap Insertion Vortex

VAREA-METER FLOW MEASUREMENT BY-PASS TYPES

J 6 Se r i e s. Pressure and Vacuum switches. features

PMG MAGNETIC FLOWMETER

Mobrey MSM400 Ultrasonic sludge density measurement system

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

Liquid Turbine Flowmeters

Model G6-S3. Repeatability ±0.02%

INSTALLATION AND OPERATION MANUAL

PIC-V Valve... 1 Unimizer (1/2 to 3 )... 2 Unimizer (4 to 6 )... 3 Automizer... 4 MVP Valve... 5

Product Data Sheet , Rev GA Catalog Content

RCM. Direct Reading Flowmeter. for Liquids or Gases

TYPE MP OSCILLATING PISTON FLOWMETER

INTERNATIONAL METAL ENGINEERING

TURBINE FLOW METER SELECTION GUIDE

Transcription:

MAX FLOW SIZES FROM 500 TO 1500 GPM (2000 TO 5600 LPM) MAX LIQUID PRESSURE 300 PSIG (20.69 BAR) XHF SERIES UNIVERSAL Flow Meters An Extra-Large Vane Style For Liquids NIST Traceable Calibration Certificate Available XHF meter with R Box DESCRIPTION These variable-area flow meters have a spring-loaded swinging vane. Mounting is in-line and in any position. Straight pipe runs before or after are not required on the 4-inch meter. The meters require 2 pipe diameters straight run before and after the meter. The all-mechanical sensing system directly drives the pointer and remote signaling devices. They handle shocks or flow surges beyond their rated capacities. The switches can be general purpose or rated for hazardous locations (all classes, groups and divisions). CALIBRATION All flow meters are individually calibrated on fluids suitable to maintain the stated accuracy for viscosities up to 3000 SSU (650 Centipoise). We also compensate for specific gravity. For NIST Traceability please consult factory. A D B E C F G The swinging vane can be manually operated with a factory supplied wrench to verify or adjust switch points, or to free the vane should it become lodged by debris in the fluid. READOUTS The flowmeter has outputs both visual and electronic. Visual displays are either pointer (with inscribed scale) or numeric (digital LCD). Electronic outputs can be mechanical switch closure, 4-20 ma analog, HART or some combination of switches with electronic outputs (for signal redundancy). CONSTRUCTION MATERIALS The meter body, moving parts, and seals are offered in a variety of materials to suit a wide range of applications: water, synthetic and petroleum based oils, paint, some corrosives, solvents, and air and gases. The flowmeter body is made up of the center section which is where the moving parts are. Sometimes it is cost effective to match this to other materials for the in and outflow sections of the meter body and flanges. See selectiohns in the How to Order section. Fluid enters at A, passes around the semi-circular vane B, exits at outlet C. The vane resists the flow because of the spring D. The further the vane is pushed the larger the passageway E becomes. This minimizes pressure drop. The vane shaft turns to operate the pointer F and remote signal devices such as the switch G. XHF Series XHF080115 1

HOW TO ORDER Select appropriate symbols and build a model code number, as in example shown: SERIES BY PRESSURE RATING Extra high vane style EXAMPLE: XHF - Q I B 8ØØGM - 32V1.Ø - = XHF Material of meter body, center section and flanges In and outflow body portions Center section Flange Aluminum Aluminum Aluminum Oil D Carbon steel Carbon steel Carbon steel Oil M Carbon steel (nickel plated) Carbon steel (nickel plated) Carbon steel (nickel plated) Water J Aluminum (hard coat) Aluminum (hard coat) Aluminum (hard coat) Oil with corrosive environment E Stainless steel (316) Stainless steel (316) Stainless steel (316) Chemicals, corrosives, water I Aluminum Brass Aluminum Water Q Carbon steel Stainless steel (316) Carbon steel Water, oil X INTERNAL MOVING PARTS Stainless steel (316 series) = I SEAL MATERIAL Buna N Water, oil B EPR Water, hot water, some caustics E Viton Acids, some caustics F Kalrez (dynamic) and Teflon (static) Corrosives, solvents T Kalrez (dynamic) and Buna N (static) Specialty A Kalrez (dynamic) and EPR (static) Specialty H Kalrez (dynamic) and Viton (static) Specialty K MAX FLOW RATE LIQUIDS GPM 500, 600, 800, 1000, 1500 = GM LPM 2000, 2500, 3000, 3500, 5600 = LM CMH 120, 140, 180, 220, 340 = CMH PORT CONNECTION 150-lb ANSI Weld-Neck Flanges Size Max. Flow Inches MM (GPM) (LPM) Symbol 4 101.6 600 2271 32W 6 152.4 1000 3785 48W 8 203.2 1500 5677 64W FLUID CHARACTERISTICS Viscosity number followed by a V (for SSU), C (for centipoise), or CS (for centistokes) followed by the specific gravity. Example: 32V1.Ø would indicate a fluid with a viscosity of 32 SSU with a specific gravity of 1. For dual viscosities (where there is a start up viscosity or where there may be a range) put in both values with a slash. Example: 32Ø/15ØV.9. Consult factory for compatibility of construction materials with the fluid involved. Viton and Kalrez are registered trademarks for DuPont Performance Elastomers. 2 XHF Series XHF080115

SERVICE Weatherproof (Type 4) Available on all boxes = W Weatherproof, corrosion proof (Type 4X) Available on all boxes = X RX1 W L - ST - 75D FLOW DIRECTION Left to right = R Right to left = L Up = U Down = D SPECIAL OPTIONS High-temp- 400 F, 300 F for transmitter options = HT Stainless steel ID tag for customer supplied information = ST Safety Glass window ref. page 5 = TG SWITCH SETTING No symbol = Lowest possible setting (usually 10% of maximum flow) Desired set point is assumed to be in flow units already selected (GPM). Give flow rate 75D followed by a D for flow going down (flow failure) or a U for flow going up. Example, 75D indicates a setting of 75 GPM in declining flow. CONTROL BOX & READOUT T Box T box always has a transmitter (4-20 ma or HART) and can be in combination with a mechanical switch for redundancy. It has two junction boxes to separate wiring for switches and transmitters. The display can be analog or digital LCD. LCD readout, 4-20mA plus option: No switches (Intrinsically safe with approved barriers) TXLØ TXL1 TXL3 high temperature TXL61 T Box Pointer, scale and 4-20 ma plus option: No switches (Intrinsically safe with approved barriers) TXØ TX1 TX2 TX3 TX4 high temperature TX61 HART, pointer, scale plus option: Two programmable HART switches THØ TH1 TH2 TH3 TH4 high temperature TH61 R Box Flow rate display plus: Display only One high vibration SPDT (3 wire) Two high vibration SPDT (3 wire) high temperature high temperature gold contact gold contact R Box R box is selected for greater visual resolution. It holds switches (general purpose and hazardous location all classes, groups and divisions) and transmitters (HART or 4-20 ma). Switch (standard service) and transmitter are offered in this control box together when signal redundancy is desired. RØ R1 R1B R2 R2B R3 R4 R61 R62 R71 R72 Flow rate display, Hazardous location switches as follows: For > 5 amp circuits One SPDT hazardous location R7 One DPDT hazardous location R17 Two SPDT hazardous location R18 Two DPDT hazardous location R19 For < 1 amp circuits One SPDT hazardous location R20 One DPDT hazardous location R21 Two SPDT hazardous location R22 Two DPDT hazardous location R23 One SPST hazardous location proximity R30 Two SPST hazardous location proximity R31 Flow rate display, 4-20 ma transmitter plus options as follows: Display and transmitter only (Intrinsically safe with approved barriers) RXØ RX1 RX2 RX3 RX4 high temperature RX61 Flow rate display, HART output plus options as follows: HART output only RHØ RH1 RH2 RH3 RH4 XHF Series XHF080115 3

CONTROL BOX SELECTION GUIDE STANDARD OFFERING: Control Box R R box is selected for greater resolution (more increments on the inscribed scale). It holds switches (general purpose and hazardous location all classes groups and divisions) and 4-20mA transmitter. Switch (standard service) and transmitter are offered in this control box together when signal redundancy is desired. You get this control box when you order any CONTROL BOX & READOUT starting with an R (see "How to Order" page). Examples: R1WR is a one switch, weatherproof box with flow from left to right. This control box is made from epoxy coated aluminum. SPECIAL OFFERING: Control Box T T box is selected for availability of two isolated junction boxes with terminal strips. This means that no direct wiring to switches or transmitters is required. Digital LCD display of flow is optional ( TXL ). It holds switches (general purpose) and 4-20mA transmitter. Switch (standard service) and transmitter are offered in this control box together when signal redundancy is desired. These are wired to separate junction boxes for signal isolation. You get this control box when you order any CONTROL BOX & READOUT starting with a T (see "How to Order" page). Examples: TX1WR is a one switch with 4-20mA transmitter, weatherproof box with flow from left to right. This control box is made from epoxy coated aluminum. Outline drawing for all control box options SECONDARY JUNCTION BOX LOCATION PRIMARY JUNCTION BOX LOCATION R12.96 [329mm] APPROXIMATE SWING RADIUS 1/2" NPT CONDUIT CONNECTION. FLANGE SIZE O.A.L. 4" 150# 21.25 6" 150# 22.25 8" 150# 19.00 ROUND ENCLOSURE JUNCTION BOX OPTIONS No Junction Box Pointer Only, No Electrical Components. 1 Junction Box One type of Electrical item Only Primary Location 1 or 2 Switches or Transmitter, but NOT both. 2 Junction Boxes Transmitter AND 1 or 2 Switches. OUTLINE OF ENCLOSURE WITH 2 SWITCHES & 2 JUNCTION BOXES. 4 XHF Series XHF080115

SPECIAL OPTIONS High temperature: (option HT) requires seals of Viton, EPR, Kalrez or Teflon (compatible with fluid). A thermal barrier (heat-resistant cloth) is added between the housing and the control box, which must be used with service option "W" (weatherproof) or "X" (corrosion resistant). A metal scale is provided. Identification tag: (option ST) customer-supplied information is stamped on a stainless steel tag that is attached to the nameplate. Safety Glass window: (option TG) replaces the standard window with "Laminated Safety Glass" ANSI Z97.1 and CPSC 1601 CFR 1201. ENGINEERING DATA FLOW & PRESSURE DROP Maximum fluid temperature: 200 F (95 C) Optional max. fluid temperature: 400 F (205 C) Maximum ambient temperature: 150 F (65 C) CSA listed only to 105 F (40 C) Maximum operating pressure (3:1 safety factor): 300 PSI (20.69 BAR) Readout accuracy, full scale: ±2% Units with max flow of 800 GPM or less have a max pressure drop of 3.8 PSI. All others have maximum pressure drop of 5.5 PSI. Universal Flow Monitors, Inc. 1755 E. Nine Mile Road P.O. Box 249 Hazel Park, MI 48030 Tel: 248-542-9635 Fax: 248-398-4274 www.flowmeters.com E-mail: ufm@flowmeters.com XHF Series XHF080115 5