EXECUTIVE SUMMARY. 28-Sep-15

Similar documents
July 25, Karla Bailey Asset Management & Engineering Manager Thunder Bay Hydro 34 Cumberland St N, Thunder Bay, ON P7A 4L4. Dear Ms.

May 20 th Mark Van de Rydt Supervisor Engineering Greater Sudbury Hydro Inc. 500 Regent Street P.O Box 250 Sudbury, ON P3E 3Y2

Wal-Mart Canada Corp.

November 28, Jim Klujber Manager of Operations Wellington North Power Inc. 290 Queen Street West, P.O. Box 359 Mount Forest, ON N0G 2L0

March 21, Mr. James F. Brown, P.Eng. Director, Infrastructure EnWin Utilities Inc. 787 Ouellette Avenue, Windsor, Ontario N9A 5T7

April 8 th Brenda L. Pinke Regulatory/CDM Manager InnPower Corporation 7251 Yonge Street Innisfil, Ontario, L9S 0J3. Dear Ms.

April 28, Doug Curtiss Chief Executive Officer Grimsby Power Inc. 231 Roberts Road Grimsby, ON L3M 5N2. Dear Mr. Curtiss:

Developing Toronto s Transit Network Plan to Public Information Meeting June 21, 2016

Ontario Employment Insurance Trends

Sunday morning road report from the Ministry of Transportation: Southwestern Ontario Road Conditions. Highways. Area. Road Condition.

185 OAK PARK ROAD OCCUPANCY AVAILABLE FOR LEASE CLASS A INDUSTRIAL FACILITY. Evan S. White* Executive Vice President

Developing Toronto s Transit Network Plan to 2031

Solar Power. Demonstration Site. Annual Performance Report 2017

RTSR Workform for Electricity Distributors (2013 Filers)

IN THE MATTER OF the Ontario Energy Board Act, 1998, S.O. 1998, c.15, Schedule B;

TRA Plan Summary Methyl Ethyl Ketone

IEQp1 Minimum Indoor Air Quality Performance Appeal Review

Decision D ATCO Electric Ltd. Decommissioning of Transmission Line 6L79. October 18, 2016

Environmental Assessment for a New Landfill Footprint at the West Carleton Environmental Centre

Alberta Electric System Operator Needs Identification Document Application. Mowat 2033S Substation

Mississauga Bus Rapid Transit Preliminary Design Project

Toxic Substance Reduction Plan Summary. Bombardier Inc. - Thunder Bay Plant. December 17, 2015

DATE: March 21, 2017 REPORT NO. PW TYPE OF REPORT CONSENT ITEM [ ] ITEM FOR CONSIDERATION [ X ] 2.0 TOPIC

Agenda Cover Memorandum

Director of Building and Deputy Chief Building Official. 1. North York Community Council approve the request for sign variance at 515 Drewry Avenue.

Adelaide Wind Power Project Turbine T05 (AD117) IEC Edition 3.0 Measurement Report

Scarborough Subway Extension. Stakeholder Advisory Meeting February 28, 2017

Project Title: Lowertown Ballpark (CHS Field) Solar Arrays Contract Number: EP4-34 Milestone Number: 1 Report Date: June 21, 2016

Confederation Line West Queensway Terrace North. May 27, 2017

Municipality of Strathroy- Caradoc

Suicide Deaths in BC

Pre-submission Consultation $ Telecommunications Tower Approval 7,700.00

DRAFT Design Study Report February 2015 Eagle River Traffic Mitigation Phase 1 MOA Project No Appendix D Utilities

Sound-absorbing spacer Sorp10

PMA Parts and Approved Repairs Issues in Europe

OPERATIONS NOISE STUDY FOR A PROPOSED AUTOMATIC CAR WASH IN THE SHERMAN OAKS DISTRICT OF LOS ANGELES

TRA Plan Summary Heavy Aromatic Naphtha

Automotive Gas Oil ( Diesel) Price Watch

City of Kingston Report to Council Report Number

OFF-PEAK DELIVERIES. Ontario Trucking Association June 26 th, Goods Movement Office Transportation Policy Branch Ministry of Transportation

Acoustic Assessment Report PRPS Reporting Station R3 and Active Bay Response (ARB) Prepared for:

VDOT Unused Facilities

TRA Plan Summary Methyl Ethyl Ketone

Acoustics Noise Vibration

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE

Glengowrie Depot Upgrade. Nick Marciano, Manager Tram Maintenance, PTS

City of Lafayette Staff Report Circulation Commission

Designation of a Community Safety Zone in Honey Harbour in the Township of Georgian Bay

An Act respecting Ville de Mont-Saint- Hilaire

Rwanda Biofuels Limited. Powering Rwanda s Development

REPORT No EN-S AJ

PEG. Pacific Economics Group, LLC Economic and Litigation Consulting EFFICIENCY RANKING AND COHORTS FOR THE 2009 RATE YEAR

Company ships gypsum from Flat Bay mine for first time in 28 years

DUFFERIN AGGREGATES ACTON QUARRY EXTENSION PROJECT

On-Street Parking Program

PART 2 GUIDELINES. To be eligible to receive a financial incentive, the following conditions must be met:

West Hills Shopping Centre Lowe s Expansion Traffic Impact Study

APPENDIX H-4 AIRCRAFT NOISE EMISSION ESTIMATES

Welcome to Open House #5 Scarborough Rapid Transit

The Regional Transportation Plan PLAN BUILD OPERATE

Appendix J. Noise Impact Assessment Report

Crop Heat Units for Corn and Other Warm-Season Crops in Ontario

RE: 67/71 Marquette Avenue Redevelopment Transportation Overview

Insolvency Statistics in Canada. Second Quarter of 2014

RICHMOND OAKS HEALTH CENTRE 6265 PERTH STREET OTTAWA, ONTARIO TRANSPORTATION BRIEF. Prepared for: Guycoki (Eastern) Limited.

Requirement Definition/Terms of Reference Satellite Beach City Hall - Solar Array Installation

WILSHIRE/RODEO. Westside Subway Extension - DRAFT IMAGES FOR DISCUSSION PURPOSES ONLY. Torti Gallas and Partners, Inc. June SAAG Workshops 2011

CertRom. BUCHAREST, S5 Calea 13 Septembrie 231A; Ph: , Fax: ;

Director of Building and Deputy Chief Building Official

Business Magazines Cross Platform Profile Circulation Certificate January to December 2014

Insolvency Statistics in Canada. Second Quarter of 2012

November 14, 2016 Reference No

ALLEGATIONS RELATED TO LABOUR AND HUMAN RIGHTS AT INDOAGRI

NOVA Gas Transmission Ltd. Appendix 2: 2013 Facility Status Update (December)

National Truck & Bus Driver Trainers Conference

Acoustics Noise Vibration

Creating a Lean and Productive Processing Facility

Summary. disposal for FY and authorize the City Manager to renew the agreement for three 3 additional terms of

Alfred & Plantagenet Multi-Residential Cart Recycling Program CIF Project Number # Final Report October 1, 2016

NGA Pre Winter Meeting

EXCEPTIONS TO RELIABILITY RULES Revision 11 February 9, 2018

Housing NOW Ontario Region

Standard Uncertainty in AEP (kwh)

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Acoustic Enclosures for Diesel Pumps

December Individual Quality Review Calendar FY 18 FY 19. Mon Tues Wed Thu Fri Sat. Sun METRO1 SAMPLE TO REGION

Scarborough Transit Planning

Addressing ambiguity in how electricity industry legislation applies to secondary networks

RESOLUTION NO. RD:MJV:KML 07/27/2017

Traffic Impact Study Proposed Residential Development (Watson Parkway North - Starwood Drive Node, City of Guelph)

Section 1 Scope of application

For Sale Exceptional Manufacturing & Office Facility Gasoline Alley Business Park

DEPARTMENT OF TRANSPORTATION. Agency Information Collection Activities; Extension of a Currently-Approved

Honorable Mayor and Members of the City Council. Disabled Placard Parking Policy for City-Owned Garages

Child Protection and Permanency. Monthly Screening and Investigation Report September 2015

DFO STATEMENT OF NEED REPORT

TORONTO TRANSIT COMMISSION REPORT NO.

Tank Farm Additional Storage Site Layout

The Commonwealth of Massachusetts

SPP Notification to Construct

Transcription:

28-Sep-15 EXECUTIVE SUMMARY HGC Engineering was retained by Union Gas ed to undertake an Acoustic Assessment of their Electrical Power Generators in Ontario. This assessment applies to power generators located at Union Gas Service Centres and Gate Stations used for emergency (standby) power. Power generators located at Union Gas Compressor Stations have been assessed as part of those facilities and are not addressed in this document. An initial screening process, outlined in the HGC Engineering report dated June 27, 2008 [1], identified 11 generators that required detailed Acoustic Assessment Reports, which were prepared in a consolidated assessment report by HGC Engineering dated June 26, 2009 [2]. Subsequent reports established that sound emissions from all assessed generators comply the applicable limits of the Ontario Ministry of the Environment and Climate Change ( MOECC ), the exception of the North Bay Service Centre. Since the last report, noise control measures have been implemented at the North Bay Service Centre, as detailed herein, such that all assessed power generators comply the applicable limits of the MOECC.

Union Gas Brantford Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level [dba re 10 12 W] 91* NS 02 Ventilation Intake 86* NS 03 Ventilation Exhaust 87* s s Table A2: Noise Impact Table ID Name Dist [m] 236 25 NS 02 Ventilation Intake 243 8 NS 03 Ventilation Exhaust 233 36 Description Level at Point of, 2 storey home approx. 240 m 36 Y* 50 Y west of power generator * Power generator was not audible or measurable at audit type measurements were conducted on Union Gas property to verify accuracy of the acoustic model agreement found to be in 1 dba.

Union Gas Headquarters, Chatham Power Generator Table A1: Noise Summary Table ID Description Power Level 101* NS 02 Ventilation Louvre 108* NS 03 Remote Cooler 114* s s Table A2: Noise Impact Table ID Name Dist [m] Dist [m] 214 39 259 37 NS 02 Ventilation Louvre 210 43 254 42 NS 03 Remote Cooler 219 44 256 41 Description Level at, 2 storey retirement home approx. 210 m northeast of power generator 51 Y 52 Y Multi storey apartment building approx. 255 m east of power generator 49 N 52 Y

Union Gas North Bay Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level 86 NS 02 Ventilation Intake 102 NS 03 Ventilation Exhaust 81 s s Table A2: Noise Impact Table ID Name Dist [m] Dist [m] 84 40 109 37 NS 02 Ventilation Intake 85 39 110 39 NS 03 Ventilation Exhaust 83 34 108 32 Description Level at, Rear yard of home approx. 80 m south of power generator 43 2 storey home approx. 110 m south of power generator 41

Union Gas Thunder Bay Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level 90* NS 02 Ventilation Louvre 87* NS 03 Remote Cooler 102* s s Table A2: Noise Impact Table ID Name Dist [m] Dist [m] 383 26 393 21 NS 02 Ventilation Louvre 386 30 398 30 NS 03 Remote Cooler 388 36 397 35 Description Level at, 2 storey future home approx. 380 m 37 N* 50 Y northwest of power generator 1 storey home approx. 400 m 36 N* 50 Y northwest of power generator * Power generator was not audible or measurable at or audit type measurements were conducted on Union Gas property to verify accuracy of the acoustic model agreement found to be in 1 dba.

Union Gas Dunnville Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level 93* s s Table A2: Noise Impact Table ID Name Dist [m] 63 41 Description Level at, 1 storey home approx. 60 m 41 Y 50 Y east of power generator

Union Gas Leamington Service Centre Power Generator Table A1: Noise Summary Table ID Description 93* s s Power Level Table A2: Noise Impact Table ID Name Dist [m] Dist [m] 111 43 57 46 Description Level at, 2 storey home approx. 110 m north 43 Y 50 Y of power generator 8 storey apartment building approx. 46 55 m northeast of power generator

Union Gas London Commissioners Road Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level 300 kw Standby Natural S1 95 O T E Gas Generator s s Table A2: Noise Impact Table ID Name R3 Dist [m] Dist [m] Dist [m] S1 300 kw Standby Natural Gas Generator 166 41 151 42 155 41 Description Level at, Base Line Road West Apartment Façade 41 Commissioners Road West Apartment Façade 42 R3 Commissioners Road West Apartment Façade 41 Note: This information was extracted from the Conestoga Rovers & Associates report entitled "Streamlined Application for Certificate of Approval (Air & Noise) for a Standby Generator, Union Gas, London, Ontario" dated September 2011.

Union Gas Simcoe Service Centre Power Generator Table A1: Noise Summary Table ID Description 82* s s Power Level Table A2: Noise Impact Table ID Name Dist [m] Dist [m] 32 26 59 23 Description Level at, Rear yard of home approx. 30 m north of power generator 26 N* 45 Y Rear yard of home approx. 60 m southwest of power generator 23 N* 45 Y * Power generator was not audible or measurable at or audit type measurements were conducted on Union Gas property to verify accuracy of the acoustic model agreement found to be in 1 dba.

Union Gas Sudbury Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level 72* NS 02 Ventilation Louvre 92* s s Table A2: Noise Impact Table ID Name Dist [m] Dist [m] 128 4 225 13 NS 02 Ventilation Louvre 128 33 227 37 Description Level at, 1 storey home approx. 130 m northwest of power generator 33 N* 50 Y 2 storey home approx. 225 m northeast of power generator 37 N* 50 Y * Power generator was not audible or measurable at or audit type measurements were conducted on Union Gas property to verify accuracy of the acoustic model agreement found to be in 1 dba.

Union Gas London North Gate Station Power Generator Table A1: Noise Summary Table ID Description Power Level 80* NS 02 Ventilation Intake 89* NS 03 Ventilation Exhaust 92* s s Table A2: Noise Impact Table ID Name Dist [m] 94 19 NS 02 Ventilation Intake 95 23 NS 03 Ventilation Exhaust 94 40 Description Level at, Rear yard of home approx. 95 m northeast of power 40 Y 50 Y generator

Union Gas Waterloo Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level 250 kw Standby Natural S1 105 O T E Gas Generator s s Table A2: Noise Impact Table ID Name R3 Dist [m] Dist [m] Dist [m] S1 250 kw Standby Natural Gas Generator 693 38 704 37 685 38 Description Level at, Mayview Crescent Residence Façade 38 Golden Eagle Road Residence Façade 37 R3 Bathurst Drive Childcare Facility Façade 38 Note: This information was extracted from the Conestoga Rovers & Associates report entitled "Streamlined Application for Certificate of Approval (Air & Noise) for a Standby Generator, Union Gas, Waterloo, Ontario" dated September 2011.

Union Gas Hamilton Service Centre Power Generator Table A1: Noise Summary Table ID Description Power Level S1 Standby Generator 103 O S, T E s s Table A2: Noise Impact Table ID Name PO PO Dist [m] Dist [m] S1 Standby Generator 158 38 239 41 Description Level at, PO Ivybridge Drive Residence Façade 38 PO Ivybridge Drive Residence Façade 41 Note: This information was extracted from the Conestoga Rovers & Associates report entitled "Acoustic Assessment Report, Union Gas, Hamilton, Ontario" dated July 2012.